Equipment and Software Setup
v1.2
Edwards EV1000 Clinical Platform
EV1000 Clinical Platform
Intro
Intro
The EV1000 clinical platform from Edwards
Lifesciences presents the physiologic status of the
patient in an entirely new, intuitive and meaningful way.
Designed in collaboration with and validated by
clinicians, the EV1000 clinical platform offers you
scalability and adaptability in both the OR and ICU.
Experience the EV1000 clinical platform and the choice
of the parameters you want, how you want to view
them — and bring clarity to every moment.
EV1000 Clinical Platform
Monitoring Configurations
FloTrac Sensor
• The FloTrac sensor can
be used independently
to monitor:
– CO / CI
– SV / SVI
– SVV
• When used with the
TruWave transducer,
CVP - SVR can be
continuously displayed
EV1000 Clinical Platform
TruWave Transducer
FloTrac Sensor
PreSep or PediaSat Oximetry Catheter
• PreSep or PediaSat
oximetry catheters can
be used independently
with EV1000 clinical
platform to monitor
ScvO2 continuously
EV1000 Clinical Platform
OM Module PreSep
Catheter
FloTrac Sensor and
PreSep Oximetry Catheter
• The FloTrac sensor
and PreSep oximetry
catheter can be used
together
EV1000 Clinical Platform
FloTrac Sensor
OM Module
PreSep
Catheter
VolumeView Set
• The VolumeView set:
– Intermittent TPTD
• GEDI
• EVLWI
• PVPI
• iCO/iCI
• iSV/iSVI
– Continuous Calibrated
• CO / CI
• SV / SVI
• SVV
EV1000 Clinical Platform
VolumeView Sensor
TruWave
Transducer
VolumeView
Thermistor
Manifold
VolumeView
Femoral
Artery
Catheter
VolumeView Set & PreSep Catheter
• The VolumeView set can
be used together with the
PreSep oximetry catheter
EV1000 Clinical Platform
OM Module
PreSep
Catheter
VolumeView Sensor
VolumeView
Femoral Arterial
Catheter
TruWave Transducer
VolumeView
Thermistor
Manifold
EV1000 Clinical Platform
Hardware Setup
EV1000 Clinical Platform
EV1000 Monitor
EV1000 Databox
• EV1000 monitor is a medical
grade computer used to display
measured and derived
parameters from the FloTrac
sensor or Volume View sensor
as well as PreSep oximetry
catheter
EV1000 Monitor
EV1000 Monitor (Front)
EV1000 Monitor (Base)
EV1000 Monitor
• Monitor On/Off
EV1000 Monitor
• Power
Supply
Connection
EV1000 Monitor
• Ethernet Connection
Communication between
Monitor and Databox
EV1000 Databox
Databox (Front)
Databox (back)
Databox (bottom)
EV1000 Databox (Front)
Sliding back plate to mount
four (4) sensors
Power / communication
indicator LED’s
EV1000 Databox (Back)
Optical Module
Connection Pressure Cable
Connection
Temperature Cable
Connection
EV1000 Databox (Back)
• Green FloTrac sensor or
VolumeView sensor connection to
EV1000 databox pressure cable with
Green Connection
• White TruWave transducer
connection to Blue EV1000 databox
pressure cable
• PX1800 cable connected to
appropriate bedside monitor CVP
pressure channel then to blue
EV1000 databox pressure cable
EV1000 Clinical Platform
TruWave Transducer
FloTrac Sensor
EV1000 Databox (Base)
Power Cable
ConnectionEthernet Cable
Connection
EV1000 Monitor (Power)
AC
EV1000 Monitor (Communications)
Edwards Ethernet Cable
EV1000 Clinical Platform
Software Setup
Start Up Screen
Patient Data Screen
Enter Patient ID
Enter Patient’s Height cm / inches
Enter Patient’s Weight lbs / Kg
Enter Patient’s Age
Enter Patient’s Gender
Confirm Patient Data and Click Home
Navigation Bar
Quick Scroll
Screen Selection
Clinical Action
Settings
Screen capture ―Snap Shot‖
Alarm Silence (2 minute)
Quick Scroll
Display Screen Selection
Select Display Screen
Select Number Parameters per Screen
Trend Line
Trend Line Setup
Numeric Value Screen
Numeric Value Screen Setup
Globe Screen
Cockpit Screen
Physiology Screen
Physio-relationship Screen
EV1000 Clinical Platform
Parameter Setup
Selecting Displayed Parameter
Touch outside the globe and
select desired parameter
Adjusting Targets and AlarmsUp / Down Arrows
Adjusting Targets and AlarmsUp / Down Arrows
Adjusting Target ValueNumeric Keypad
Adjusting Target ValueDisplay : Cockpit Screen
Adjusting Target ValueDisplay : Globes
Adjusting Target ValueDisplay : Trend Screen
Adjusting Target ValueDisplay : Large Numbers
Audible Alarms On / Off (Permanent)
Target Ranges On / OffRange Off / High – Low Alarms On
EV1000 Clinical Platform
Settings
Settings
Patient Data
Monitor Settings
Parameter Settings
Parameter SettingsAlarm / Targets
Parameter SettingsAdjust Scales
Parameter SettingsTime Intervals / Averaging
Data Download
Demo Mode
Demo Mode
EngineeringEdwards technical support only
Help
EV1000 Clinical Platform
Clinical Actions
Clinical Actions
Zero and Waveform
Zero FloTrac Sensor or
VolumeView Sensor
Transducer Not Connected
Click ― – 0 – ― to Zero
Zero Complete
CO Parameters Displayed
CO parameters
displayed after the
FloTrac sensor is
zeroed and the
VolumeView
sensor is
calibrated against
TPTD
Clinical Actions
Transpulmonary
Thermodilution
(TPTD)
TPTD
TPTD
TPTD
Select Injectate Bolus Volume
TPTDLung Resection Selection
TPTDCatheter Temperature Probe Connected?
TPTDThermistor Manifold
TPTDStart
• Attach lure lock Syringe with
cold Normal Saline bolus
• Wait for ―inject‖ on monitor
• Inject in one smooth motion
• Do not start and stop
• Remove syringe
• Repeat, max 6 times
TPTDBolus
TPTDAlert Bolus : Irregular Injection
TPTDReview Boluses
TPTDEdit Boluses
TPTDAccept Edited Bolus = Calibrate CCO
TPTDAverage of Edited Bolus
TPTDReview Physiology Screen
• Volumetric
– GEDV
– GEF
– EVLW
– PVPI
• Continuous
– CO / CI
– SV / SVI
– SVR / SVRI
– SVV
EVLW
EVLWI of above 7 mL / kg
display on graphic and
progressively fill the lung
as it increases
Clinical Actions
Oximetry Calibration
Oximetry Calibration
Default Display ScvO2
Oximetry Calibration
Connect Optical Module
Oximetry Calibration
Optical Module Initializing
In Vitro Calibration
In Vitro Calibration
Hemoglobin or Hematocrit
In Vitro Calibration
Enter H&H
In Vitro Calibration
H&H Calibrating
H&H Update Finished
Press ―Start‖
In Vitro Calibration
Calibration in Progress
In Vitro Calibration
ScvO2 Displayed
In Vivo Calibration
In Vivo Calibration
Baseline Setup in Progress
In Vivo Calibration
Ready Equipment then ―Draw‖
In Vivo Calibration
Enter ScvO2 and H&H
In Vivo Calibration
Enter Hemoglobin or Hematocrit
In Vivo Calibration
Enter ScvO2
In Vivo Calibration
Confirm Data and Press ―Calibrate‖
In Vivo Calibration
Calibration 25 Second Update
In Vivo Calibration
Calibrated ScvO2 Value Displayed
Recall Optical Module Data
Recall Optical Module Data
Hemoglobin or Hematocrit
Hemoglobin or Hematocrit Update
Hemoglobin or Hematocrit Update
Clinical Actions
Intervention Analysis
Intervention Analysis
Intervention Analysis
Intervention Analysis
Intervention Analysis
Intervention Analysis
Intervention Analysis
Clinical Actions
Derived Value Calculator and
Event Review
More
Derived Value Calculator
Event Review
EV1000 Clinical Platform
Choose the EV1000 clinical platform and
the choice of the parameters you want,
how you want to view them—and bring
clarity to every moment.
For Professional Use. CAUTION: Federal (United States) law restricts this device to sale by or on the order
of a physician. See instructions for use for full prescribing information, including indications,
contraindications, warnings, precautions and adverse events.
Edwards, Edwards Lifesciences, the stylized E logo, EV1000, FloTrac, PediaSat, PreSep, TruWave and VolumeView are trademarks of Edwards
Lifesciences Corporation.
© 2011 Edwards Lifesciences Corporation. All rights reserved. AR06594