Septic tanks are primary treatment unit based on anaerobic process.

have wide application in new construction of sewage treatment plants

or in the up-grading of existing facilities as part of pre-treatment for

roughing the pollution load of sewage. Septic tanks work like a trap

for coarse solids (especially when there are not gridirons, always

recommended) and they remove organic materials and suspended

solids.

fermentation (i.e. in the absence of oxygen) which is precisely "septic

mode".

to concentrate, in the first room, sedimentation of the sludge, in an calm area, and to

let flotation of substances that, for their minor specific gravity, tend to float on the surface.

In the following room, we get a progressive clarification of wastewater.

All compartments are sized to achieve a biological stabilization of organic

sediments(fermentation or anaerobic digestion) and a good balance between BOD5,

Nitrogen and Phosphorus.

An over-sizing of septic tanks, therefore, may cause an unbalance of these factors,

producing adverse effects on the purification process and a consistent reduction of

following secondary treatment of sewage.

Telcom’s septic tanks are made in LLDPE (Linear Low Density Polyethylene) material

completely recyclable. They present manhole for inspection and removal of sludge, a

waste inlet and a outlet with a rubber seal, for clarified water, a vent for expulsion of

biogas produced.

PRIMARY TREATEMENTS

Telcom’s septic tanks are normally sized for 200 liters per E.I. (equivalent inhabitant), but whenyou design this device at the beginning of a treatment system for activated sludge, you haveto scale to 100 liters per E.I.

1

Page 3: Eco Aquarius Big Plants 2009

For Telcom’s septic tanks sized for 100 litres per E.I. you have to provide a standard emptying 2-3times/year.

For Telcom’s septic tanks sized for 200 litres per E.I. you have to provide a standard emptying 1-2times/year.

SEPTIC TANKS

-

-

-

50

60

75

85

90

100

125

150

175

200

225

250

30

50

60

100

120

150

170

180

200

250

300

350

400

450

500

ECOVSV3000

ECOVSV5000

ECOVSV6000

VS10000

VS12000

VS15000

VS17000

VS18500

VS20000

VS25000

VS30000

VS35000

VS40000

VS45000

VS50000

3107

5110

5993

10000

12000

15000

17000

18500

20000

25000

30000

35000

40000

45000

50000

146

184

185

225

225

225

225

225

225

225

225

225

225

225

225

146

184

185

320

370

452

502

543

584

716

848

980

1112

1244

1376

219

229

257

235

235

235

235

235

235

235

235

235

235

235

235

1*

1*

1*

2

2

2

2

2

2

3

4

4

5

5

6

125

160

160

160

160

160

160

160

160

160

160

160

160

160

160

192

197

224

204

204

204

204

204

204

204

204

204

204

204

204

188

193

220

200

200

200

200

200

200

200

200

200

200

200

200

hi(cm)

hu(cm)

E.I.sized for 200 lt.

E.I.sized

for 100 lt.

VOLUME TOTALE(litri)

ARTICOLO

2

Page 4: Eco Aquarius Big Plants 2009

FUNCTIONAL DETAILS

SUSPENDED BIOMASS PLANTS

“A” Zone – EQUALIZATION - DENITRIFICATION

This section is designed to equalize the hydraulic load and to make as homogeneous as possible,

the incoming pollutant load in the wastewater plant. Sudden loading peaks (shock loads) should

produce, indeed, negative results on purifying efficiency because micro-organisms do not adapt

their selves quickly to the changes of their environment. But, in the same compartment, properly

dimensioned, the correct recirculation of activated sludge, coming from the oxidation and secondary

sedimentation, realize an anoxic (i.e. without oxygen) environment, that produce denitrification

of wastewater and reduce nitrogen values in its various oxidized forms or in gas.

“B” zone - OXIDATION

In this compartment you can find the oxidative phase of process. Sewage is here subjected to an

intensive treatment by an intense artificial ventilation and this environment is very rich with oxygen.

In this way physical and chemical, specially biologic, reactions produce their effects and degrade

the organic pollutant load. The high microbial concentrations present in the oxidation section

responsible for the purification of wastewater, are made possible by the continuous recirculation

of activated sludge settled in the next section (room of sedimentation).

“C” Zone - SEDIMENTATION

In the sedimentation room, due to calm of water, there is the separation and precipitation of

sludge which is then recirculated by an pneumatic extractor (air-lift), to equalization and

oxidation compartment (see OXIDATION).

The clarified and purified wastewater is sent to the next phase of treatment, if

provided by the designer. Only the sludge produced in excess

from depurative process (excess sludge)

must be periodically

r e m o v e d

from the

plant.

Telcom’s SUSPENDED BIOMASS plants: they are biologic-based systems purification which use

activated sludge with a strong aeration.

The degradation of organic parts and suspended solids present in the sewage occurs through the

action of bacteria that feed their selves by pollutants, purifying, in this way, the wastewater. An

intense artificial ventilation ensures a good proliferation of those bacteria that form colonies as

"flakes of mud" typical for suspended biomass.

“A” zoneSeptic Tank

3

Page 5: Eco Aquarius Big Plants 2009

MODULAR PLANTSMod. EQ + FA

COMPACT PLANTSMod. EQFA

“A” zone “B” zone “C” zone

“B” zone “C” zone

4

Page 6: Eco Aquarius Big Plants 2009

Primary treatement

EQFA

SUSPENDED BIOMASS PLANTS

306090

120

E. I. Volume Totale(litri)

ARTICOLO

EQFA13500EQFA23500EQFA33500EQFA43500

13500235003850043500

225225225225

411675939

1203

235235235235

3579

160160160160

204204204204

200200200200

5000100001500020000

5000100001500020000

CARATTERISTICHE MANUFATTOCARATTERISTICHE PROGETTUALI

TABELLA 3 - Categoria 2

306090

120150180

E. I. Volume Totale(litri)

ARTICOLO

EQFA12000EQFA18500EQFA28500

EQFA33500BEQFA43500BEQFA50000B

120001850028500335004350050000

225225225225225225

370543807939

12031376

235235235235235235

34679

10

160160160160160160

204204204204204204

200200200200200200

35005000

10000100001350015000

50001000015000200002500030000

CARATTERISTICHE MANUFATTOCARATTERISTICHE PROGETTUALI

TABELLA 3 - Categoria 1

EQFA system are compact plants based on Suspended Biomass. The are able to treat sewagecoming from different type of structures/houses, as below shown. These categories are identifiedaccording to the time of their production of sewage. We consideredfor first category when the production time of sewage is during 16hours/day, the second when there the production time is 8 hours/day.EQFA system are complete with a standard cabinet with any electricalequipment necessary to manage the system

“C” zone“A” zone “B” zone

VOLUME TOTALEEQUALIZZAZIONE

DENITRIFICAZIONE(litri)

VOL. TOT.OSSIDAZIONE

(litri)

VOLUME TOTALEEQUALIZZAZIONE

DENITRIFICAZIONE(litri)

VOL. TOT.OSSIDAZIONE

(litri)

Zona A Zona B

Zona A Zona B

Long Action System SUSPENDED BIOMASS

CATEGORY 1Production Time : 16 hours

RESIDENCES

AIRPORTS

TRADE CENTER

DEPARTMENTS STORES

HOTELS

COMMERCIAL ACTIVITIES (STORE)

BARRACKS

COLLEGES

HOSPITALS

CAMPING

TOURIST VILLAGES

SPORTING CLUBS

5

Page 7: Eco Aquarius Big Plants 2009

*Nota: in caso di Scarichi SEPARATI rivolgersi al nostro Ufficio Tecnico.

Vasca contatto

Pozzetto fiscale

TRATTAMENTOPRIMARIO

ECOVSV3000ECOVSV6000

VS10000VS12000

ECO CLO 300ECO CLO 500ECO CLO 750ECO CLO1000

VASCACONTATTOCLORAZIONE

CHIARIFICAZIONE

POZZETTOFISCALE

POZ100 GIPOZ100 GIPOZ100 GIPOZ300 GI

3500350035003500

0,790,9

2,182,18

220220380380

TRATTAMENTOPRIMARIO

ECOVSV3000ECOVSV6000

VS10000VS12000VS15000VS18500

ECO CLO 300ECO CLO 500ECO CLO 750ECO CLO1000ECO CLO1500ECO CLO1500

VASCACONTATTOCLORAZIONE

CHIARIFICAZIONE

POZZETTOFISCALE

POZ100 GIPOZ100 GIPOZ100 GIPOZ300 GIPOZ300 GIPOZ300 GI

350035003500350050005000

0,790,9

2,182,182,182,88

220220380380380380

ne

VOL. TOT.SEDIMENTAZIONE

SECONDARIA(litri)

Potenza TOT.installata

(KW)

TENSIONE(V)

VOL. TOT.SEDIMENTAZIONE

SECONDARIA(litri)

Potenza TOT.installata

(KW)

TENSIONE(V)

Zona C

Zona C

ACCESSORI A RICHIESTA PER SCARICHI CONGIUNTI*

ACCESSORI A RICHIESTA PER SCARICHI CONGIUNTI*

COMPACT PLANTS

TO DISCHARGE

TO RUNNING WATERS

CATEGORY 2Production time : 8 hours

BARS

RESTAURANTS

CINEMAS

INDUSTRIAL BUILDINGS

SERVICE STATIONS

FAST FOODS

RESTORANTS

OFFICES

SCHOOLS

PUBLICK PARKS

SWIMMING POOLS

STADIUM

6

Page 8: Eco Aquarius Big Plants 2009

Primary treatment

EQFA

SUSPENDED BIOMASS PLANTS

25507095

120145

E. I.Volume Totale

(litri)ARTICOLO

EQFA12000EQFA18500

EQFA23500BEQFA33500BEQFA40000

EQFA50000B

120001850023500335004000050000

225225225225225225

370543675939

11121376

235235235235235235

34578

10

160160160160160160

204204204204204204

200200200200200200

350050005000

100001000015000

50001000015000200002500030000

CARATTERISTICHE MANUFATTOCARATTERISTICHE PROGETTUALI

TABELLA 4 - Categoria 1

25507095

120

E. I. ARTICOLO

EQFA13500EQFA23500EQFA28500EQFA38500EQFA50000

1350023500285003850050000

225225225225225

411675807

10711376

235235235235235

3568

10

160160160160160

204204204204204

200200200200200

500010000100001500020000

500010000150002000025000

CARATTERISTICHE MANUFATTOCARATTERISTICHE PROGETTUALI

TABELLA 4 - Categoria 2

EQFA system are compact plants based on Suspended Biomass. The are able to treat sewagecoming from different type of structures/houses, as below shown. These categories are identifiedaccording to the time of their production of sewage. We consideredfor first category when the production time of sewage is during16 hours/day, the second when there the production time is 8hours/day.EQFA system are complete with a standard cabinet with anyelectrical equipment necessary to manage the system.

“A” zone “B” zone

VOLUME TOTALEEQUALIZZAZIONE

DENITRIFICAZIONE(litri)

VOL. TOT.OSSIDAZIONE

(litri)

Zona A Zona B

VOLUME TOTALEEQUALIZZAZIONE

DENITRIFICAZIONE(litri)

VOL. TOT.OSSIDAZIONE

(litri)

Zona A Zona B

Long Action System SUSPENDED BIOMASS

CATEGORY 1Production Time : 16 hours

RESIDENCES

AIRPORTS

TRADE CENTER

DEPARTMENTS STORES

HOTELS

COMMERCIAL ACTIVITIES (STORE)

BARRACKS

COLLEGES

HOSPITALS

CAMPING

TOURIST VILLAGES

SPORTING CLUBS

7

Page 9: Eco Aquarius Big Plants 2009

*Nota: in caso di Scarichi SEPARATI rivolgersi al nostro Ufficio Tecnico.

Final disinfection

Inspection

TRATTAMENTOPRIMARIO

ECOVSV3000ECOVSV5000ECOVSV6000

VS10000VS12000VS15000

ECO CLO 300ECO CLO 500ECO CLO 750ECO CLO1000ECO CLO1500ECO CLO1500

ACCESSORI A RICHIESTA PER SCARICHI CONGIUNTI*

VASCACONTATTOCLORAZIONE

CHIARIFICAZIONE

POZZETTOFISCALE

POZ100 GIPOZ100 GIPOZ100 GIPOZ100 GIPOZ300 GIPOZ300 GI

350035003500350050005000

0,790,9

2,182,182,182,88

220220380380380380

TRATTAMENTOPRIMARIO

ECO CLO 300ECO CLO 500ECO CLO 750ECO CLO1000ECO CLO1500

VASCACONTATTOCLORAZIONE

CHIARIFICAZIONE

POZZETTOFISCALE

POZ100 GIPOZ100 GIPOZ100 GIPOZ100 GIPOZ300 GI

35003500350035005000

0,790,9

2,182,182,18

220220380380380

ECOVSV3000ECOVSV5000ECOVSV6000

VS10000VS12000

ACCESSORI A RICHIESTA PER SCARICHI CONGIUNTI*

TO DISCHARGE

TO LANDS FOR

IRRIGATION

COMPACT PLANTS

“C” zone

VOL. TOT.SEDIMENTAZIONE

SECONDARIA(litri)

Potenza TOT.installata

(KW)

TENSIONE(V)

Zona C

VOL. TOT.SEDIMENTAZIONE

SECONDARIA(litri)

Potenza TOT.installata

(KW)

TENSIONE(V)

Zona C

CATEGORY 2Production time : 8 hours

BARS

RESTAURANTS

CINEMAS

INDUSTRIAL BUILDINGS

SERVICE STATIONS

FAST FOODS

RESTORANTS

OFFICES

SCHOOLS

PUBLICK PARKS

SWIMMING POOLS

STADIUM

8

Page 10: Eco Aquarius Big Plants 2009

SUSPENDED BIOMASS PLANTS

EQ15000EQ18500EQ23500EQ25000EQ28500EQ30000EQ33500EQ38500EQ40000EQ45000EQ48500EQ50000

ARTICOLO

EQUALIZZATORI

ABITANTI EQUIVALENTITABELLA 3 - Categoria 2

170200250300350---

400---

500---

600---

------------

170200---

250---

300---

350

---200250300350---

400---

500---

600---

---------------

200---

250---

300---

350

ABITANTI EQUIVALENTITABELLA 3 - Categoria 1

ABITANTI EQUIVALENTITABELLA 4 - Categoria 1

ABITANTI EQUIVALENTITABELLA 4 - Categoria 2

CATEGORY 1Production Time : 16 hours

RESIDENCES

AIRPORTS

TRADE CENTER

DEPARTMENTS STORES

HOTELS

COMMERCIAL ACTIVITIES (STORE)

BARRACKS

COLLEGES

HOSPITALS

CAMPING

TOURIST VILLAGES

SPORTING CLUBS

9

Page 11: Eco Aquarius Big Plants 2009

150001850023500250002850030000335003850040000450004850050000

225225225225225225225225225225225225

452543675716807848939

10711203124412951376

235235235235235235235235235235235235

160160160160160160160160160160160160

204204204204204204204204204204204204

200200200200200200200200200200200200

0,60,60,60,60,60,60,60,60,60,60,60,6

220220220220220220220220220220220220

CARATTERISTICHE TECNICHE

VOLUME TOTALE(litri)

POTENZA TOTALEinstallata

(KW)

TENSIONE(V)

EQUALIZER DEVICE

CATEGORY 2Production time : 8 hours

BARS

RESTAURANTS

CINEMAS

INDUSTRIAL BUILDINGS

SERVICE STATIONS

FAST FOODS

RESTORANTS

OFFICES

SCHOOLS

PUBLICK PARKS

SWIMMING POOLS

STADIUM

10

Page 12: Eco Aquarius Big Plants 2009

*Accessories are not included in dimensions table.

SUSPENDED BIOMASS PLANTS

ARTICOLO

FANGHI ATTIVI A PORTATA DIRETTA

170200250300350400500600700800

200250300350400500600700800

1000

11x2,514x2,5

8x710x711x714x78x15

10x1511x1514x15

160160160160160160160160160160

TABELLA 4 TABELLA 3

1,41,72,12,52,93,34,25,05,86,7

1,72,12,52,93,34,25,05,86,78,3

160160160160160160160160160160

Active sludge direct flow plants are equipped with electrical blower and/or compressor. Switchunit, on demand.

PORTATA MEDIAORARIA

PORTATA MEDIAORARIA

Long Action System SUSPENDED BIOMASS

E. I. E. I.

11

Page 13: Eco Aquarius Big Plants 2009

NOTE: to ensure all outlet limits, you have to insure a constant flow duringall the day, because this plant cannot elaborate shock loads over averageloads as shown in following table.

400004850060000700008000097000

120000140000160000194000

350004000050000600007000080000

100000120000140000160000

500085001000010000100001700020000200002000034000

2233347779

380380380380380380380380380380

CARATTERISTICHE TECNICHE

POTENZA TOTALEinstallata

(KW)

TENSIONE(V)

VOLUME TOTALE(litri)

VOLUME TOTALEOSSIDAZIONE

(litri)

VOLUME TOTALESEDIMENTAZIONE

SECONDARIA(litri)

ACTIVE SLUDGE DIRECT FLOW

12

Page 14: Eco Aquarius Big Plants 2009

*gli ingombri di massima non comprendono gli accessori.

Primary treatement

Equalizer denitrification

SUSPENDED BIOMASS PLANTS

200250300350400500600700

30000385004500050000600007700090000

100000

21x2,526x2,523x726x722x727x7

24x1527x15

E. I.Impianto

aFanghi Attivi

EqualizzazioneDenitrificazione

MODELLICARATTERISTICHE TECNICHE

TABELLA 3 - Categoria 2

200250300350400500600700800

1000

E. I.Impianto

aFanghi Attivi

EqualizzazioneDenitrificazione

18x2,522x2,518x720x723x727x7

25x1521x1523x1528x15

18500235002500028500335004000048500570006000080000

MODELLICARATTERISTICHE TECNICHE

TABELLA 3 - Categoria 1

EQ+FA are modular plants using suspended Biomass to treat sewages coming from different typeof structures/houses, as below shown.These plants are characterized by production time of wastwater, so we consider 16 or 8 hoursfor category 1 or 2. All plants are quipped with a standard cabinet with any electrical equipmentnecessary to manage the system according to CE standard.

“A” Zone

VOLUME TOTALEEQUALIZZAZIONE

DENITRIFICAZIONE(litri)

Zona A

VOLUME TOTALEEQUALIZZAZIONE

DENITRIFICAZIONE(litri)

Zona A

Long Action System SUSPENDED BIOMASS

CATEGORY 1Production Time : 16 hours

RESIDENCES

AIRPORTS

TRADE CENTER

DEPARTMENTS STORES

HOTELS

COMMERCIAL ACTIVITIES (STORE)

BARRACKS

COLLEGES

HOSPITALS

CAMPING

TOURIST VILLAGES

SPORTING CLUBS

CATEGORY 2Production time : 8 hours

BARS

RESTAURANTS

CINEMAS

INDUSTRIAL BUILDINGS

SERVICE STATIONS

FAST FOODS

RESTORANTS

OFFICES

SCHOOLS

PUBLICK PARKS

SWIMMING POOLS

STADIUM

13

Page 15: Eco Aquarius Big Plants 2009

Final disinfection

Inspection

Suspended Biomass

TRATTAMENTOPRIMARIO

ECO CLO2000ECO CLO2000ECO CLO2500ECO CLO2500ECO CLO4000ECO CLO4000ECO CLO6000ECO CLO6000ECO CLO7500ECO CLO10000

ACCESSORI A RICHIESTA

VASCACONTATTOCLORAZIONE

CHIARIFICAZIONE

POZZETTOFISCALE

POZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GI

350004000050000600007000080000

100000120000

50008500

100001000010000170002000020000

380380380380380380380380

POZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GI

ECO CLO2000ECO CLO2000ECO CLO2500ECO CLO2500ECO CLO4000ECO CLO4000ECO CLO6000ECO CLO6000

TRATTAMENTOPRIMARIO

ACCESSORI A RICHIESTA

VASCACONTATTOCLORAZIONE

CHIARIFICAZIONE

POZZETTOFISCALE

33445688

350004000050000600007000080000

100000120000140000160000

50008500

1000010000100001700020000200002000034000

334446888

10

380380380380380380380380380380

“B” zone “C” zone

VOL. TOT.OSSIDAZIONE

(litri)

VOL. TOT.SEDIMENTAZIONE

SECONDARIA(litri)

POTENZA TOTALEinstallata

(KW)

TENSIONE(V)

Zona B Zona C

VOL. TOT.OSSIDAZIONE

(litri)

VOL. TOT.SEDIMENTAZIONE

SECONDARIA(litri)

POTENZA TOTALEinstallata

(KW)

TENSIONE(V)

Zona B Zona C

TO DISCHARGE

TO RUNNING WATERS

MODULAR PLANTS

14

Page 16: Eco Aquarius Big Plants 2009

*gli ingombri di massima non comprendono gli accessori.

Primary Treatement

Equalizer denitrification

SUSPENDED BIOMASS PLANTS

170200250300350400500600700800

A.E.Impianto

aFanghi Attivi

EqualizzazioneDenitrificazione

17x2,521x2,518x719x722x726x7

23x1527x1523x1525x15

15000185002350025000285003350040000485005700060000

MODELLICARATTERISTICHE TECNICHE

TABELLA 4 - Categoria 1

170200250300350400500600700

A.E.Impianto

aFanghi Attivi

EqualizzazioneDenitrificazione

22x2,523x2,522x724x727x724x7

23x1525x1529x15

2850030000385004500050000600007700090000

100000

MODELLICARATTERISTICHE TECNICHE

TABELLA 4 - Categoria 2

“A” zone

Zona A

VOS

VOLUME TOTALEEQUALIZZAZIONE

DENITRIFICAZIONE(litri)

Zona A

VO

VOLUME TOTALEEQUALIZZAZIONE

DENITRIFICAZIONE(litri)

EQ+FA are modular plants using suspended Biomass to treat sewages coming from different typeof structures/houses, as below shown.These plants are characterized by production time of wastwater, so we consider 16 or 8 hoursfor category 1 or 2. All plants are quipped with a standard cabinet with any electrical equipmentnecessary to manage the system according to CE standard.

Long Action System SUSPENDED BIOMASS

CATEGORY 1Production Time : 16 hours

RESIDENCES

AIRPORTS

TRADE CENTER

DEPARTMENTS STORES

HOTELS

COMMERCIAL ACTIVITIES (STORE)

BARRACKS

COLLEGES

HOSPITALS

CAMPING

TOURIST VILLAGES

SPORTING CLUBS

CATEGORY 2Production time : 8 hours

BARS

RESTAURANTS

CINEMAS

INDUSTRIAL BUILDINGS

SERVICE STATIONS

FAST FOODS

RESTORANTS

OFFICES

SCHOOLS

PUBLICK PARKS

SWIMMING POOLS

STADIUM

15

Page 17: Eco Aquarius Big Plants 2009

Final disinfection

inspection

Suspended Biomass

TRATTAMENTOPRIMARIO

ECO CLO1500ECO CLO2000ECO CLO2000ECO CLO2500ECO CLO2500ECO CLO4000ECO CLO4000ECO CLO6000ECO CLO6000ECO CLO7500

ACCESSORI A RICHIESTA

VASCACONTATTOCLORAZIONE

CHIARIFICAZIONE

POZZETTOFISCALE

POZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GI

350004000050000600007000080000

100000120000140000160000

50008500

1000010000100001700020000200002000034000

334445778

10

380380380380380380380380380380

350004000050000600007000080000100000120000140000

50008500

10000100001000017000200002000020000

334446888

380380380380380380380380380

ECO CLO1500ECO CLO2000ECO CLO2000ECO CLO2500ECO CLO2500ECO CLO4000ECO CLO4000ECO CLO6000ECO CLO6000

POZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GI

TRATTAMENTOPRIMARIO

ACCESSORI A RICHIESTA

VASCACONTATTOCLORAZIONE

CHIARIFICAZIONE

POZZETTOFISCALE

Zona B

VOL. TOT.OSSIDAZIONE

(litri)

VOL. TOT.OSSIDAZIONE

(litri)

“B” zone “C” zone

Zona C

VOL. TOT.SEDIMENTAZIONE

SECONDARIA(litri)

POTENZA TOTALEinstallata

(KW)

TENSIONE(V)

Zona B Zona C

VOL. TOT.SEDIMENTAZIONE

SECONDARIA(litri)

POTENZA TOTALEinstallata

(KW)

TENSIONE(V)

MODULAR PLANTS

TO DISCHARGE

TO LANDS FOR

IRRIGATION

16

Page 18: Eco Aquarius Big Plants 2009

WARNINGS

MORE: it is dangerous water with a pH values higher than 9.5 and less than 5.5 and with an amount

of dissolved oxygen always below to 2 mg / l. parameters of nitrogen output will conform when the sewage input observe ratio of 10% approx.

to BOD5; parameters of phosphorus output will conform when the sewage input observe the ratio of 5%

to BOD5; the parameters of non-biodegradable input already comply with the legislation laws because

they biologically degraded. be considered hazardous to nitrification of the sewage of the following ranges/substances:

SCARICOTAB. III

SCARICOTAB. IV

SCARICOTAB. III

SCARICOTAB. IV

ZINCOARSENICOFENOLICROMO TOT.SOLFURINICHEL

0,50,50,52,012

0,50,050,11,00,50,2

FLUOROPIOMBOCLORURIRAMETENSIOATTIVINON BIODEGRADABILI

10,12000,10,5

60,2

12000,12

THE EFFLUENT OF OUR PLANTS WILL RESPECT ENVIRONMENTAL STANDARDS AND LIMITSOF POLLUTANT, ONLY IF:

supplied data for project are responding to the real situation; Installation and maintenance are performed regularly and correctly according to the manual

and Technical Annex; the wastewater produced is domestic wastwater or comparable to it; in the plant are not introduced bactericides, ammonia, chlorine or any product harmful to

the bacterial flora or with deleterious affect on the cleaning action; washing water and rainwater are not conveyed to the plant such as solid coarse (nappies,

plastic bags, etc..) that could damage or cause any part of obstructions; to the wastewater treatment plant is unable to work with concentrations that exceed the

following limits (in mg / l) for the following substances:

RANGE[mg/l]

NICHELCROMO

0,25 - 3,00,25

PARAMETRORANGE[mg/l]

PARAMETRO

RAMEZINCO

0,1 - 0,53

THE MANUFACTURER RESERVES THE RIGHT TO MAKE CHANGES AND/OR IMPROVEMENTS IN DESIGNS &DIMENSIONS WITHOUT NOTICE AND WITHOUT INCURRING OBLIGATION. THE MEASURES OF SPACE AREEXPRESSED IN CENTIMETERS WITH TOLERANCE OF ± 1%, HAVE THE CAPACITY TOLERANCE ± 10%.

17

Page 19: Eco Aquarius Big Plants 2009

This warranty, attached to the instruction booklet or manual technical Telcom SpA provides withthe purchase of its products, is additional and not substitute any other right which protect theconsumer / purchaser of the product, leaving the rights of the latter holds under the Italian DLGS2.02.2002 nr. 24, witch has implemented in Italy Directive 1999/44/EC on guarantees forconsumer goods.1) I hereby guarantee Telcom S.p.A. guarantees the product against any defects in material orworkmanship for a period of 24 months from the date of original purchase. Each containermanufactured by Telcom S.p.A. is subjected to testing, however, could suffer damage due tostorage or transport, for which from time to time be determined responsibility: it is for this reasonthat the Telcom SpA advise the consumer / purchaser of container to verify its integrity prior toits installation and use.2) If during the warranty period, there were defects in materials or workmanship (the original dateof purchase), the Telcom SpA will repair or (at the discretion of Telcom SpA) to replace theproduct or its defective parts in the terms and conditions below, at no charge to the cost of laboror of parts, a provided that the unit under the guarantees received from the factory Telcom SpAto expense of consumers.3) Telcom S.p.A. disclaims any liability for loss or damage to goods, services,including economic loss or intangible - the price paid for the product - the loss of profits, revenue,data, use or enjoyment of this or any other associated products - loss or damageindirect, or caused to others due to the defect found, incidental or consequential. This appliesto loss or damage under any legal theory, including negligence and other acts tort, breach ofcontract, express or implied warranty and strict liability.4) Assistance under warranty will be performed only if the defective product will be presentedwithin the time provided by law together with the sales invoice or receipt for tax purposes inoriginal.5) The Telcom S.p.A. reserves the right to refuse intervention guarantees the absence of suchdocuments.6) This guarantee will cease if the indication of the model or serial number reported on the producthave been modified, deleted, removed or made illegible.7) This warranty does not cover the costs and risks associated with the transportation of yourproduct to Telcom S.p.A.Are excluded from this Warranty:a) The expression of periodic maintenance and repair or replacement of parts due to wear andwear;b) damage or defects resulting from use, improper handling or use of the product for purposesother thannormal, ie that given in the instruction manual or technical manual;c) damage by misuse of the product, misuse BREAKFAST:

incorrect installation or use of the product for purposes other than those provided or failure tocomply with instructionsTelcom S.p.A. the installation and use;

improper maintenance of the product, not in accordance with the instructions Telcom SpA thecorrectmaintenance;

installation or use of the product does not comply with technical standards and safety in thecountrywhich the product is installed or used, and the rules worked out in the booklet instructions.

WARRANTY

18

Page 20: Eco Aquarius Big Plants 2009

ACCESSORI

E/SOFFIANTEA CANALE LATERALE BISTADIO

Completa di silenziatore in aspirazionee mandata e valvola di sicurezza.

E/POMPA DI SOLLEVAMENTO

COMPRESSORE LINEARE A MEMBRANA

Bassa rumorosità Basso consumo

MISCELA BATTERICO ENZIMATICA

Appositamente formulata per l’innesco o ilripristino dell’attività batterica nei sistemidi depurazione biologica di acque reflue.

19

Page 21: Eco Aquarius Big Plants 2009

ACCESSORI

TORRETTA Cod. INPOZ 550 GR

dimensioni [cm] L=68, P=68, H=60

POZZETTO GRIGLIATORE Cod. POZ 550 GR

dimensioni [cm] L=68, P=68, H=60

GUARNIZIONEGuarnizione doppio labbro

Cod.: Guarnizione Ø 100 mm Cod.: Guarnizione Ø 125 mm Cod.: Guarnizione Ø 160 mm Cod.: Guarnizione Ø 200 mm Cod.: Guarnizione Ø 250 mm Cod.: Guarnizione Ø 315 mm

POZZETTO GREZZO Cod.: POZ 100GR

Chiusino Ø320 mm dimensioni [cm]: 48x48x75H capacità 100 litri

Cod.: POZ 300GR Chiusino Ø420 mm dimensioni [cm]: 73x73x82H capacità 300 litri

Pozzetto: Per le esigenze impiantistiche è stato realizzato un pozzettomonolitico a otto facce, che trova il suo impiego nella realizzazionedelle diverse soluzioni proposte: esso può fungere da pozzetto diispezione, come pozzetto di confluenza/ripartizione, oppure comepozzetto di manovra. La particolare forma consente con facilità direalizzare il collegamento con direzione a 45° o multipli.

20

Page 22: Eco Aquarius Big Plants 2009

Tabella 3Prima Colonna

Tabella 4Tabella 3Seconda

REFERRING TABLES

Attached notes to Tables 3 and 4Annex 5 of Part Three -

D. Lgs. n° 152/06and subsequent modifications:

(*) The limits for discharge into the sewer systemare mandatory in the absence of limits set by thearea or in the absence of a final treatment able tomeet the emission limits the final discharge. Differentlimits set by manager must be made to comply withthe stated in footnote 2 to Table 5 on substancesdangerous.1) For watercourses, the maximum variation betweenaverage temperatures of any section of the coursewater upstream and downstream from the point ofrelease must not exceed 3° C. At least half of anysection downstream such variation shall not exceed1° C. For lakes, the temperature of the exhaustexceed 30 ° C and the temperature is raised. Bodycontainer must not exceed3° C over 50 meters away from the point of release.In the artificial channels, the maximum value averagetemperature of any section must not exceed 35° C,the condition that is conditional on the consent ofthe person who manages the channel. For the seaand the areas of the mouth water courses are notsignificant, the temperature exhaust must not exceed35 ° C and the increase the temperature of thecontainer must not in no case exceed 3 ° C above1000 meters distance from the point of release. Itmust also be ensure environmental compatibility ofthe discharge container with the body and preventedthe formation of thermal barriers at the mouth ofthe rivers.2) As for waste water discharges the urban limitsare indicated in Table 1 and, for sensitive areas,including those in Table 2. As Concerning the dischargeof industrial waste water with destination to sensitiveareas the concentration of total phosphorus and totalnitrogen must be respectively 1 and 10 mg / L.3) These limits do not apply to the discharge intothe sea, in accordingly zones mouth waters aretreated as marine coastal areas, provided that atleast on half of a any section downstream of thedischarge are not disturbed the natural variations inthe concentration of sulfates or chlorides.4) In the authorization of the exhaust for thetreatment of urban waste water by the competentauthority will set the limit appropriate in relationto the environmental situation and health and hygieneof the water body and the receptor practice. Werecommend a limit of no more than 5000 cfu/100mL.5) The toxicity test is required. In addition to theessay on Daphnia magna, may be carried out testsacute toxicity to Ceriodaphnia dubia, Selenastrumcapricornutum, bacteria or organisms bioluminescentisuch as Artemia salina, discharges to water or saltother bodies that will be among those listed underItem 4 of this Annex. In the case of run multipletests to consider the toxicity worst result. The positiveresult of test toxicity does not determine the directapplication of penalties provided for in Title V, alsodetermines the obligation in-depth analyticalinvestigation of the Research the causes of toxicityand their removal.

Saggio di tossicitàacuta (5)

Azoto totaleBerillioVanadio

Composti organiciaromatici totali

Composti organiciazotati totali

Pesticidi totali(esclusi i fosforati)

tra cui:- aldrin

- dieldrin- endrin- isodrin

Solventi clorurati

Escherichia coli (4)

Sostanze

pHTemperatura

Colore

Odore

5 (comeO2)

AlluminioArsenico

BarioBoro

CadmioCromo totale

Cromo VIFerro

ManganeseMercurioNichelPiomboRame

SelenioStagnoZinco

Solfuri (come H S)

3)

CloruriFluoruri

(come NH4)

Grassi e olianimali/vegetali

FenoliAldeidi

Solventi organiciaromatici

Solventi organiciazotati

BOD

COD

Cloro attivo libero

Solfiti (come SO

Solfati (come SO4)

Idrocarburi totali

Tensioattivi totaliPesticidi fosforati

Materiali grossolani

Solidi sospesi totali

Cianuri totali(come CN)

Azoto ammoniacale

Azoto nitroso(come N)

Azoto nitrico(come N)

Fosforo totale(come P)

mg/Lmg/Lmg/L

mg/L

mg/L

mg/L

mg/L

mg/L

mg/Lmg/Lmg/Lmg/Lmg/Lmg/Lmg/Lmg/Lmg/Lmg/Lmg/Lmg/Lmg/Lmg/Lmg/Lmg/L

mg/L

mg/Lmg/L

mg/L

mg/L

mg/Lmg/L

mg/L

mg/L

mg/L

mg/L

mg/L

mg/Lmg/Lmg/L

mg/L

mg/L

mg/Lmg/L

mg/L

mg/Lmg/Lmg/Lmg/Lmg/L

UFC/100mL

≤ 0,01≤ 0,01≤ 0,002≤ 0,002

≤ 1

nota

Unità diMisura Scarico in acque

superficialiScarico in pubblica

fognatura (*)

Reflui cherecapitanosul suolo

6-810

Assenti

25

20

100

10,05100,5

1 -

20,2

0,20,10,1

0,0023

0,5

0,20,5

0,5

500

2001

2

5

0,10,5

0,5

diluizione 1:20

Non deve esserecausa di molestie

Assenti

≤ 80

≤ 40

≤ 160

≤ 1≤ 0,5≤ 20≤ 2

≤ 0,02≤ 2

≤ 0,2≤ 2≤ 2

≤ 0,005≤ 2

≤ 0,2≤ 0,1≤ 0,03≤ 10≤ 0,5

≤ 0,5

≤ 0,2≤ 1

≤ 1

≤ 1000

≤ 1200

≤ 6

≤ 10

≤ 15

≤ 0,6

≤ 20

≤ 20

≤ 5≤ 0,5≤ 1

≤ 0,2

≤ 0,1

≤ 2≤ 0,10

≤ 0,05

diluizione 1:40

Non deve esserecausa di molestie

assenti

≤ 200

≤ 250

≤ 500

≤ 2,0≤ 0,5

-≤ 4

≤ 0,02≤ 4

≤ 0,20≤ 4≤ 4

≤ 0,005≤ 4

≤ 0,3≤ 0,4≤ 0,03

-≤ 1,0

≤ 1,0

≤ 0,3≤ 2

≤ 2

≤ 1000

≤ 1200

≤ 12

≤ 10

≤ 30

≤ 0,6

≤ 30

≤ 40

≤ 10≤ 1≤ 2

≤ 0,4

≤ 0,2

≤ 4≤ 0,10

≤ 0,05

≤ 0,01≤ 0,01≤ 0,002≤ 0,002

≤ 2

5,5 – 9,5

Non percettibile con Non percettibile con

- nota

150,10,1

0,01

0,01

Il campione non èaccettabile quando,dopo 24 ore, il numerod e g l i o r g a n i s m iimmobili è uguale omaggiore del 50% deltotale.

Il campione non èaccettabile quando,dopo 24 ore, il numerod e g l i o r g a n i s m iimmobili è uguale omaggiore del 80% deltotale.

Il campione non èaccettabile quando,dopo 24 ore, il numerod e g l i o r g a n i s m iimmobili è uguale omaggiore del 50% deltotale.

5,5 – 9,5SAR

2

0,01

(1) (1)

(2) (2)

(comeO2)(2) (2)

(2) (2)

(3) (3)

(3) (3)

(2) (2)

(2) (2)

(2) (2)

(2) (2)

(4) (4)

(5) (5)

(5) (5)

Attached notes to Tables 3 and 4 Annex 5 of Part Three -D. Lgs. n° 152/06 and subsequent modifications:

21

Page 23: Eco Aquarius Big Plants 2009

REFERRING CONTACT PERSON

THE MANUFACTURER RESERVES THE RIGHT TO MAKE CHANGES AND/OR IMPROVEMENTS IN DESIGNS &DIMENSIONS WITHOUT NOTICE AND WITHOUT INCURRING OBLIGATION. THE MEASURES OF SPACE AREEXPRESSED IN CENTIMETERS WITH TOLERANCE OF ± 1%, HAVE THE CAPACITY TOLERANCE ± 10%.

Technological innovationand cutting-edge choiches

We were the first to realize the potential ofrotational, to become leaders industry with 19 plantsCarousel, 450 employees, plants in Europe, America,Asia for an extension total of 54 000 m2 covered.Industrial and innovative technologies are integralpart of our way of doing business. But the decisivefactor of our business success is the love for ourwork, with great passion which our staff followedall the steps of production process, from creationto print hand finishing of products. We have awarehouse of the largest in the world, with over 20000 m2 covered and a simultaneous capacity loadequal to eighteen trucks. We have establishedbusiness contacts in the five continents and multiplejoint ventures. Experience and a solid foundation togrow.

ISO 9001 / 14001 Certified Company

The ISO 9000 and ISO 14000 standards are whichvoluntary organizations can choose to join, andproviding a set of criteria to be met, the order toseek and ensure that its actions in field of qualitymanagement (ISO 9001) and environmental (ISO14001) is in compliance with stricter operationalprocedures. Companies that choose to adhere tothese rules volunteers are screened on a regularbasis by a third entity certificate, which guaranteesthe conformity of these systems managementstandards international. Adherence to these standardsensures a supply side certain qualitative anddocumented, and a production compatible, from anenvironmental point of view, with the territory. ISO9001 and 14001 identify the seriousness and qualityTelcom acquired in thirty years of experience.Obtaining the certification UNI EN ISO 14001 is anofficial recognition of the policy respect of theterritory sought by Telcom SpA and is a constantincentive to improve.

Light weight and shockproof

Recyclables Materials

Heat and frost resistant

Resistent to every weather conditions

Easy to install

Easier storage and transport

Good Value: best ratio price/duration.

7 GOOD REASONS TO CHOSETHERMOPLASTIC WASTE-WATER

TREATEMENT SYSTEMS

QUALITY AND CERTIFICATIONS

22

Page 24: Eco Aquarius Big Plants 2009

Print: T

LC

OM

CO

MM

ER

CIA

L D

EP

T. -

2009