ECOAQUARIUS - GRANDI IMPIANTI
Septic tanks are primary treatment unit based on anaerobic process.
have wide application in new construction of sewage treatment plants
or in the up-grading of existing facilities as part of pre-treatment for
roughing the pollution load of sewage. Septic tanks work like a trap
for coarse solids (especially when there are not gridirons, always
recommended) and they remove organic materials and suspended
solids.
fermentation (i.e. in the absence of oxygen) which is precisely "septic
mode".
to concentrate, in the first room, sedimentation of the sludge, in an calm area, and to
let flotation of substances that, for their minor specific gravity, tend to float on the surface.
In the following room, we get a progressive clarification of wastewater.
All compartments are sized to achieve a biological stabilization of organic
sediments(fermentation or anaerobic digestion) and a good balance between BOD5,
Nitrogen and Phosphorus.
An over-sizing of septic tanks, therefore, may cause an unbalance of these factors,
producing adverse effects on the purification process and a consistent reduction of
following secondary treatment of sewage.
Telcom’s septic tanks are made in LLDPE (Linear Low Density Polyethylene) material
completely recyclable. They present manhole for inspection and removal of sludge, a
waste inlet and a outlet with a rubber seal, for clarified water, a vent for expulsion of
biogas produced.
PRIMARY TREATEMENTS
Telcom’s septic tanks are normally sized for 200 liters per E.I. (equivalent inhabitant), but whenyou design this device at the beginning of a treatment system for activated sludge, you haveto scale to 100 liters per E.I.
1
For Telcom’s septic tanks sized for 100 litres per E.I. you have to provide a standard emptying 2-3times/year.
For Telcom’s septic tanks sized for 200 litres per E.I. you have to provide a standard emptying 1-2times/year.
SEPTIC TANKS
-
-
-
50
60
75
85
90
100
125
150
175
200
225
250
30
50
60
100
120
150
170
180
200
250
300
350
400
450
500
ECOVSV3000
ECOVSV5000
ECOVSV6000
VS10000
VS12000
VS15000
VS17000
VS18500
VS20000
VS25000
VS30000
VS35000
VS40000
VS45000
VS50000
3107
5110
5993
10000
12000
15000
17000
18500
20000
25000
30000
35000
40000
45000
50000
146
184
185
225
225
225
225
225
225
225
225
225
225
225
225
146
184
185
320
370
452
502
543
584
716
848
980
1112
1244
1376
219
229
257
235
235
235
235
235
235
235
235
235
235
235
235
1*
1*
1*
2
2
2
2
2
2
3
4
4
5
5
6
125
160
160
160
160
160
160
160
160
160
160
160
160
160
160
192
197
224
204
204
204
204
204
204
204
204
204
204
204
204
188
193
220
200
200
200
200
200
200
200
200
200
200
200
200
hi(cm)
hu(cm)
E.I.sized for 200 lt.
E.I.sized
for 100 lt.
VOLUME TOTALE(litri)
ARTICOLO
2
FUNCTIONAL DETAILS
SUSPENDED BIOMASS PLANTS
“A” Zone – EQUALIZATION - DENITRIFICATION
This section is designed to equalize the hydraulic load and to make as homogeneous as possible,
the incoming pollutant load in the wastewater plant. Sudden loading peaks (shock loads) should
produce, indeed, negative results on purifying efficiency because micro-organisms do not adapt
their selves quickly to the changes of their environment. But, in the same compartment, properly
dimensioned, the correct recirculation of activated sludge, coming from the oxidation and secondary
sedimentation, realize an anoxic (i.e. without oxygen) environment, that produce denitrification
of wastewater and reduce nitrogen values in its various oxidized forms or in gas.
“B” zone - OXIDATION
In this compartment you can find the oxidative phase of process. Sewage is here subjected to an
intensive treatment by an intense artificial ventilation and this environment is very rich with oxygen.
In this way physical and chemical, specially biologic, reactions produce their effects and degrade
the organic pollutant load. The high microbial concentrations present in the oxidation section
responsible for the purification of wastewater, are made possible by the continuous recirculation
of activated sludge settled in the next section (room of sedimentation).
“C” Zone - SEDIMENTATION
In the sedimentation room, due to calm of water, there is the separation and precipitation of
sludge which is then recirculated by an pneumatic extractor (air-lift), to equalization and
oxidation compartment (see OXIDATION).
The clarified and purified wastewater is sent to the next phase of treatment, if
provided by the designer. Only the sludge produced in excess
from depurative process (excess sludge)
must be periodically
r e m o v e d
from the
plant.
Telcom’s SUSPENDED BIOMASS plants: they are biologic-based systems purification which use
activated sludge with a strong aeration.
The degradation of organic parts and suspended solids present in the sewage occurs through the
action of bacteria that feed their selves by pollutants, purifying, in this way, the wastewater. An
intense artificial ventilation ensures a good proliferation of those bacteria that form colonies as
"flakes of mud" typical for suspended biomass.
“A” zoneSeptic Tank
3
MODULAR PLANTSMod. EQ + FA
COMPACT PLANTSMod. EQFA
“A” zone “B” zone “C” zone
“B” zone “C” zone
4
Primary treatement
EQFA
SUSPENDED BIOMASS PLANTS
306090
120
E. I. Volume Totale(litri)
ARTICOLO
EQFA13500EQFA23500EQFA33500EQFA43500
13500235003850043500
225225225225
411675939
1203
235235235235
3579
160160160160
204204204204
200200200200
5000100001500020000
5000100001500020000
CARATTERISTICHE MANUFATTOCARATTERISTICHE PROGETTUALI
TABELLA 3 - Categoria 2
306090
120150180
E. I. Volume Totale(litri)
ARTICOLO
EQFA12000EQFA18500EQFA28500
EQFA33500BEQFA43500BEQFA50000B
120001850028500335004350050000
225225225225225225
370543807939
12031376
235235235235235235
34679
10
160160160160160160
204204204204204204
200200200200200200
35005000
10000100001350015000
50001000015000200002500030000
CARATTERISTICHE MANUFATTOCARATTERISTICHE PROGETTUALI
TABELLA 3 - Categoria 1
EQFA system are compact plants based on Suspended Biomass. The are able to treat sewagecoming from different type of structures/houses, as below shown. These categories are identifiedaccording to the time of their production of sewage. We consideredfor first category when the production time of sewage is during 16hours/day, the second when there the production time is 8 hours/day.EQFA system are complete with a standard cabinet with any electricalequipment necessary to manage the system
“C” zone“A” zone “B” zone
VOLUME TOTALEEQUALIZZAZIONE
DENITRIFICAZIONE(litri)
VOL. TOT.OSSIDAZIONE
(litri)
VOLUME TOTALEEQUALIZZAZIONE
DENITRIFICAZIONE(litri)
VOL. TOT.OSSIDAZIONE
(litri)
Zona A Zona B
Zona A Zona B
Long Action System SUSPENDED BIOMASS
CATEGORY 1Production Time : 16 hours
RESIDENCES
AIRPORTS
TRADE CENTER
DEPARTMENTS STORES
HOTELS
COMMERCIAL ACTIVITIES (STORE)
BARRACKS
COLLEGES
HOSPITALS
CAMPING
TOURIST VILLAGES
SPORTING CLUBS
5
*Nota: in caso di Scarichi SEPARATI rivolgersi al nostro Ufficio Tecnico.
Vasca contatto
Pozzetto fiscale
TRATTAMENTOPRIMARIO
ECOVSV3000ECOVSV6000
VS10000VS12000
ECO CLO 300ECO CLO 500ECO CLO 750ECO CLO1000
VASCACONTATTOCLORAZIONE
CHIARIFICAZIONE
POZZETTOFISCALE
POZ100 GIPOZ100 GIPOZ100 GIPOZ300 GI
3500350035003500
0,790,9
2,182,18
220220380380
TRATTAMENTOPRIMARIO
ECOVSV3000ECOVSV6000
VS10000VS12000VS15000VS18500
ECO CLO 300ECO CLO 500ECO CLO 750ECO CLO1000ECO CLO1500ECO CLO1500
VASCACONTATTOCLORAZIONE
CHIARIFICAZIONE
POZZETTOFISCALE
POZ100 GIPOZ100 GIPOZ100 GIPOZ300 GIPOZ300 GIPOZ300 GI
350035003500350050005000
0,790,9
2,182,182,182,88
220220380380380380
ne
VOL. TOT.SEDIMENTAZIONE
SECONDARIA(litri)
Potenza TOT.installata
(KW)
TENSIONE(V)
VOL. TOT.SEDIMENTAZIONE
SECONDARIA(litri)
Potenza TOT.installata
(KW)
TENSIONE(V)
Zona C
Zona C
ACCESSORI A RICHIESTA PER SCARICHI CONGIUNTI*
ACCESSORI A RICHIESTA PER SCARICHI CONGIUNTI*
COMPACT PLANTS
TO DISCHARGE
TO RUNNING WATERS
CATEGORY 2Production time : 8 hours
BARS
RESTAURANTS
CINEMAS
INDUSTRIAL BUILDINGS
SERVICE STATIONS
FAST FOODS
RESTORANTS
OFFICES
SCHOOLS
PUBLICK PARKS
SWIMMING POOLS
STADIUM
6
Primary treatment
EQFA
SUSPENDED BIOMASS PLANTS
25507095
120145
E. I.Volume Totale
(litri)ARTICOLO
EQFA12000EQFA18500
EQFA23500BEQFA33500BEQFA40000
EQFA50000B
120001850023500335004000050000
225225225225225225
370543675939
11121376
235235235235235235
34578
10
160160160160160160
204204204204204204
200200200200200200
350050005000
100001000015000
50001000015000200002500030000
CARATTERISTICHE MANUFATTOCARATTERISTICHE PROGETTUALI
TABELLA 4 - Categoria 1
25507095
120
E. I. ARTICOLO
EQFA13500EQFA23500EQFA28500EQFA38500EQFA50000
1350023500285003850050000
225225225225225
411675807
10711376
235235235235235
3568
10
160160160160160
204204204204204
200200200200200
500010000100001500020000
500010000150002000025000
CARATTERISTICHE MANUFATTOCARATTERISTICHE PROGETTUALI
TABELLA 4 - Categoria 2
EQFA system are compact plants based on Suspended Biomass. The are able to treat sewagecoming from different type of structures/houses, as below shown. These categories are identifiedaccording to the time of their production of sewage. We consideredfor first category when the production time of sewage is during16 hours/day, the second when there the production time is 8hours/day.EQFA system are complete with a standard cabinet with anyelectrical equipment necessary to manage the system.
“A” zone “B” zone
VOLUME TOTALEEQUALIZZAZIONE
DENITRIFICAZIONE(litri)
VOL. TOT.OSSIDAZIONE
(litri)
Zona A Zona B
VOLUME TOTALEEQUALIZZAZIONE
DENITRIFICAZIONE(litri)
VOL. TOT.OSSIDAZIONE
(litri)
Zona A Zona B
Long Action System SUSPENDED BIOMASS
CATEGORY 1Production Time : 16 hours
RESIDENCES
AIRPORTS
TRADE CENTER
DEPARTMENTS STORES
HOTELS
COMMERCIAL ACTIVITIES (STORE)
BARRACKS
COLLEGES
HOSPITALS
CAMPING
TOURIST VILLAGES
SPORTING CLUBS
7
*Nota: in caso di Scarichi SEPARATI rivolgersi al nostro Ufficio Tecnico.
Final disinfection
Inspection
TRATTAMENTOPRIMARIO
ECOVSV3000ECOVSV5000ECOVSV6000
VS10000VS12000VS15000
ECO CLO 300ECO CLO 500ECO CLO 750ECO CLO1000ECO CLO1500ECO CLO1500
ACCESSORI A RICHIESTA PER SCARICHI CONGIUNTI*
VASCACONTATTOCLORAZIONE
CHIARIFICAZIONE
POZZETTOFISCALE
POZ100 GIPOZ100 GIPOZ100 GIPOZ100 GIPOZ300 GIPOZ300 GI
350035003500350050005000
0,790,9
2,182,182,182,88
220220380380380380
TRATTAMENTOPRIMARIO
ECO CLO 300ECO CLO 500ECO CLO 750ECO CLO1000ECO CLO1500
VASCACONTATTOCLORAZIONE
CHIARIFICAZIONE
POZZETTOFISCALE
POZ100 GIPOZ100 GIPOZ100 GIPOZ100 GIPOZ300 GI
35003500350035005000
0,790,9
2,182,182,18
220220380380380
ECOVSV3000ECOVSV5000ECOVSV6000
VS10000VS12000
ACCESSORI A RICHIESTA PER SCARICHI CONGIUNTI*
TO DISCHARGE
TO LANDS FOR
IRRIGATION
COMPACT PLANTS
“C” zone
VOL. TOT.SEDIMENTAZIONE
SECONDARIA(litri)
Potenza TOT.installata
(KW)
TENSIONE(V)
Zona C
VOL. TOT.SEDIMENTAZIONE
SECONDARIA(litri)
Potenza TOT.installata
(KW)
TENSIONE(V)
Zona C
CATEGORY 2Production time : 8 hours
BARS
RESTAURANTS
CINEMAS
INDUSTRIAL BUILDINGS
SERVICE STATIONS
FAST FOODS
RESTORANTS
OFFICES
SCHOOLS
PUBLICK PARKS
SWIMMING POOLS
STADIUM
8
SUSPENDED BIOMASS PLANTS
EQ15000EQ18500EQ23500EQ25000EQ28500EQ30000EQ33500EQ38500EQ40000EQ45000EQ48500EQ50000
ARTICOLO
EQUALIZZATORI
ABITANTI EQUIVALENTITABELLA 3 - Categoria 2
170200250300350---
400---
500---
600---
------------
170200---
250---
300---
350
---200250300350---
400---
500---
600---
---------------
200---
250---
300---
350
ABITANTI EQUIVALENTITABELLA 3 - Categoria 1
ABITANTI EQUIVALENTITABELLA 4 - Categoria 1
ABITANTI EQUIVALENTITABELLA 4 - Categoria 2
CATEGORY 1Production Time : 16 hours
RESIDENCES
AIRPORTS
TRADE CENTER
DEPARTMENTS STORES
HOTELS
COMMERCIAL ACTIVITIES (STORE)
BARRACKS
COLLEGES
HOSPITALS
CAMPING
TOURIST VILLAGES
SPORTING CLUBS
9
150001850023500250002850030000335003850040000450004850050000
225225225225225225225225225225225225
452543675716807848939
10711203124412951376
235235235235235235235235235235235235
160160160160160160160160160160160160
204204204204204204204204204204204204
200200200200200200200200200200200200
0,60,60,60,60,60,60,60,60,60,60,60,6
220220220220220220220220220220220220
CARATTERISTICHE TECNICHE
VOLUME TOTALE(litri)
POTENZA TOTALEinstallata
(KW)
TENSIONE(V)
EQUALIZER DEVICE
CATEGORY 2Production time : 8 hours
BARS
RESTAURANTS
CINEMAS
INDUSTRIAL BUILDINGS
SERVICE STATIONS
FAST FOODS
RESTORANTS
OFFICES
SCHOOLS
PUBLICK PARKS
SWIMMING POOLS
STADIUM
10
*Accessories are not included in dimensions table.
SUSPENDED BIOMASS PLANTS
ARTICOLO
FANGHI ATTIVI A PORTATA DIRETTA
170200250300350400500600700800
200250300350400500600700800
1000
11x2,514x2,5
8x710x711x714x78x15
10x1511x1514x15
160160160160160160160160160160
TABELLA 4 TABELLA 3
1,41,72,12,52,93,34,25,05,86,7
1,72,12,52,93,34,25,05,86,78,3
160160160160160160160160160160
Active sludge direct flow plants are equipped with electrical blower and/or compressor. Switchunit, on demand.
PORTATA MEDIAORARIA
PORTATA MEDIAORARIA
Long Action System SUSPENDED BIOMASS
E. I. E. I.
11
NOTE: to ensure all outlet limits, you have to insure a constant flow duringall the day, because this plant cannot elaborate shock loads over averageloads as shown in following table.
400004850060000700008000097000
120000140000160000194000
350004000050000600007000080000
100000120000140000160000
500085001000010000100001700020000200002000034000
2233347779
380380380380380380380380380380
CARATTERISTICHE TECNICHE
POTENZA TOTALEinstallata
(KW)
TENSIONE(V)
VOLUME TOTALE(litri)
VOLUME TOTALEOSSIDAZIONE
(litri)
VOLUME TOTALESEDIMENTAZIONE
SECONDARIA(litri)
ACTIVE SLUDGE DIRECT FLOW
12
*gli ingombri di massima non comprendono gli accessori.
Primary treatement
Equalizer denitrification
SUSPENDED BIOMASS PLANTS
200250300350400500600700
30000385004500050000600007700090000
100000
21x2,526x2,523x726x722x727x7
24x1527x15
E. I.Impianto
aFanghi Attivi
EqualizzazioneDenitrificazione
MODELLICARATTERISTICHE TECNICHE
TABELLA 3 - Categoria 2
200250300350400500600700800
1000
E. I.Impianto
aFanghi Attivi
EqualizzazioneDenitrificazione
18x2,522x2,518x720x723x727x7
25x1521x1523x1528x15
18500235002500028500335004000048500570006000080000
MODELLICARATTERISTICHE TECNICHE
TABELLA 3 - Categoria 1
EQ+FA are modular plants using suspended Biomass to treat sewages coming from different typeof structures/houses, as below shown.These plants are characterized by production time of wastwater, so we consider 16 or 8 hoursfor category 1 or 2. All plants are quipped with a standard cabinet with any electrical equipmentnecessary to manage the system according to CE standard.
“A” Zone
VOLUME TOTALEEQUALIZZAZIONE
DENITRIFICAZIONE(litri)
Zona A
VOLUME TOTALEEQUALIZZAZIONE
DENITRIFICAZIONE(litri)
Zona A
Long Action System SUSPENDED BIOMASS
CATEGORY 1Production Time : 16 hours
RESIDENCES
AIRPORTS
TRADE CENTER
DEPARTMENTS STORES
HOTELS
COMMERCIAL ACTIVITIES (STORE)
BARRACKS
COLLEGES
HOSPITALS
CAMPING
TOURIST VILLAGES
SPORTING CLUBS
CATEGORY 2Production time : 8 hours
BARS
RESTAURANTS
CINEMAS
INDUSTRIAL BUILDINGS
SERVICE STATIONS
FAST FOODS
RESTORANTS
OFFICES
SCHOOLS
PUBLICK PARKS
SWIMMING POOLS
STADIUM
13
Final disinfection
Inspection
Suspended Biomass
TRATTAMENTOPRIMARIO
ECO CLO2000ECO CLO2000ECO CLO2500ECO CLO2500ECO CLO4000ECO CLO4000ECO CLO6000ECO CLO6000ECO CLO7500ECO CLO10000
ACCESSORI A RICHIESTA
VASCACONTATTOCLORAZIONE
CHIARIFICAZIONE
POZZETTOFISCALE
POZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GI
350004000050000600007000080000
100000120000
50008500
100001000010000170002000020000
380380380380380380380380
POZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GI
ECO CLO2000ECO CLO2000ECO CLO2500ECO CLO2500ECO CLO4000ECO CLO4000ECO CLO6000ECO CLO6000
TRATTAMENTOPRIMARIO
ACCESSORI A RICHIESTA
VASCACONTATTOCLORAZIONE
CHIARIFICAZIONE
POZZETTOFISCALE
33445688
350004000050000600007000080000
100000120000140000160000
50008500
1000010000100001700020000200002000034000
334446888
10
380380380380380380380380380380
“B” zone “C” zone
VOL. TOT.OSSIDAZIONE
(litri)
VOL. TOT.SEDIMENTAZIONE
SECONDARIA(litri)
POTENZA TOTALEinstallata
(KW)
TENSIONE(V)
Zona B Zona C
VOL. TOT.OSSIDAZIONE
(litri)
VOL. TOT.SEDIMENTAZIONE
SECONDARIA(litri)
POTENZA TOTALEinstallata
(KW)
TENSIONE(V)
Zona B Zona C
TO DISCHARGE
TO RUNNING WATERS
MODULAR PLANTS
14
*gli ingombri di massima non comprendono gli accessori.
Primary Treatement
Equalizer denitrification
SUSPENDED BIOMASS PLANTS
170200250300350400500600700800
A.E.Impianto
aFanghi Attivi
EqualizzazioneDenitrificazione
17x2,521x2,518x719x722x726x7
23x1527x1523x1525x15
15000185002350025000285003350040000485005700060000
MODELLICARATTERISTICHE TECNICHE
TABELLA 4 - Categoria 1
170200250300350400500600700
A.E.Impianto
aFanghi Attivi
EqualizzazioneDenitrificazione
22x2,523x2,522x724x727x724x7
23x1525x1529x15
2850030000385004500050000600007700090000
100000
MODELLICARATTERISTICHE TECNICHE
TABELLA 4 - Categoria 2
“A” zone
Zona A
VOS
VOLUME TOTALEEQUALIZZAZIONE
DENITRIFICAZIONE(litri)
Zona A
VO
VOLUME TOTALEEQUALIZZAZIONE
DENITRIFICAZIONE(litri)
EQ+FA are modular plants using suspended Biomass to treat sewages coming from different typeof structures/houses, as below shown.These plants are characterized by production time of wastwater, so we consider 16 or 8 hoursfor category 1 or 2. All plants are quipped with a standard cabinet with any electrical equipmentnecessary to manage the system according to CE standard.
Long Action System SUSPENDED BIOMASS
CATEGORY 1Production Time : 16 hours
RESIDENCES
AIRPORTS
TRADE CENTER
DEPARTMENTS STORES
HOTELS
COMMERCIAL ACTIVITIES (STORE)
BARRACKS
COLLEGES
HOSPITALS
CAMPING
TOURIST VILLAGES
SPORTING CLUBS
CATEGORY 2Production time : 8 hours
BARS
RESTAURANTS
CINEMAS
INDUSTRIAL BUILDINGS
SERVICE STATIONS
FAST FOODS
RESTORANTS
OFFICES
SCHOOLS
PUBLICK PARKS
SWIMMING POOLS
STADIUM
15
Final disinfection
inspection
Suspended Biomass
TRATTAMENTOPRIMARIO
ECO CLO1500ECO CLO2000ECO CLO2000ECO CLO2500ECO CLO2500ECO CLO4000ECO CLO4000ECO CLO6000ECO CLO6000ECO CLO7500
ACCESSORI A RICHIESTA
VASCACONTATTOCLORAZIONE
CHIARIFICAZIONE
POZZETTOFISCALE
POZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GI
350004000050000600007000080000
100000120000140000160000
50008500
1000010000100001700020000200002000034000
334445778
10
380380380380380380380380380380
350004000050000600007000080000100000120000140000
50008500
10000100001000017000200002000020000
334446888
380380380380380380380380380
ECO CLO1500ECO CLO2000ECO CLO2000ECO CLO2500ECO CLO2500ECO CLO4000ECO CLO4000ECO CLO6000ECO CLO6000
POZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GIPOZ300 GI
TRATTAMENTOPRIMARIO
ACCESSORI A RICHIESTA
VASCACONTATTOCLORAZIONE
CHIARIFICAZIONE
POZZETTOFISCALE
Zona B
VOL. TOT.OSSIDAZIONE
(litri)
VOL. TOT.OSSIDAZIONE
(litri)
“B” zone “C” zone
Zona C
VOL. TOT.SEDIMENTAZIONE
SECONDARIA(litri)
POTENZA TOTALEinstallata
(KW)
TENSIONE(V)
Zona B Zona C
VOL. TOT.SEDIMENTAZIONE
SECONDARIA(litri)
POTENZA TOTALEinstallata
(KW)
TENSIONE(V)
MODULAR PLANTS
TO DISCHARGE
TO LANDS FOR
IRRIGATION
16
WARNINGS
MORE: it is dangerous water with a pH values higher than 9.5 and less than 5.5 and with an amount
of dissolved oxygen always below to 2 mg / l. parameters of nitrogen output will conform when the sewage input observe ratio of 10% approx.
to BOD5; parameters of phosphorus output will conform when the sewage input observe the ratio of 5%
to BOD5; the parameters of non-biodegradable input already comply with the legislation laws because
they biologically degraded. be considered hazardous to nitrification of the sewage of the following ranges/substances:
SCARICOTAB. III
SCARICOTAB. IV
SCARICOTAB. III
SCARICOTAB. IV
ZINCOARSENICOFENOLICROMO TOT.SOLFURINICHEL
0,50,50,52,012
0,50,050,11,00,50,2
FLUOROPIOMBOCLORURIRAMETENSIOATTIVINON BIODEGRADABILI
10,12000,10,5
60,2
12000,12
THE EFFLUENT OF OUR PLANTS WILL RESPECT ENVIRONMENTAL STANDARDS AND LIMITSOF POLLUTANT, ONLY IF:
supplied data for project are responding to the real situation; Installation and maintenance are performed regularly and correctly according to the manual
and Technical Annex; the wastewater produced is domestic wastwater or comparable to it; in the plant are not introduced bactericides, ammonia, chlorine or any product harmful to
the bacterial flora or with deleterious affect on the cleaning action; washing water and rainwater are not conveyed to the plant such as solid coarse (nappies,
plastic bags, etc..) that could damage or cause any part of obstructions; to the wastewater treatment plant is unable to work with concentrations that exceed the
following limits (in mg / l) for the following substances:
RANGE[mg/l]
NICHELCROMO
0,25 - 3,00,25
PARAMETRORANGE[mg/l]
PARAMETRO
RAMEZINCO
0,1 - 0,53
THE MANUFACTURER RESERVES THE RIGHT TO MAKE CHANGES AND/OR IMPROVEMENTS IN DESIGNS &DIMENSIONS WITHOUT NOTICE AND WITHOUT INCURRING OBLIGATION. THE MEASURES OF SPACE AREEXPRESSED IN CENTIMETERS WITH TOLERANCE OF ± 1%, HAVE THE CAPACITY TOLERANCE ± 10%.
17
This warranty, attached to the instruction booklet or manual technical Telcom SpA provides withthe purchase of its products, is additional and not substitute any other right which protect theconsumer / purchaser of the product, leaving the rights of the latter holds under the Italian DLGS2.02.2002 nr. 24, witch has implemented in Italy Directive 1999/44/EC on guarantees forconsumer goods.1) I hereby guarantee Telcom S.p.A. guarantees the product against any defects in material orworkmanship for a period of 24 months from the date of original purchase. Each containermanufactured by Telcom S.p.A. is subjected to testing, however, could suffer damage due tostorage or transport, for which from time to time be determined responsibility: it is for this reasonthat the Telcom SpA advise the consumer / purchaser of container to verify its integrity prior toits installation and use.2) If during the warranty period, there were defects in materials or workmanship (the original dateof purchase), the Telcom SpA will repair or (at the discretion of Telcom SpA) to replace theproduct or its defective parts in the terms and conditions below, at no charge to the cost of laboror of parts, a provided that the unit under the guarantees received from the factory Telcom SpAto expense of consumers.3) Telcom S.p.A. disclaims any liability for loss or damage to goods, services,including economic loss or intangible - the price paid for the product - the loss of profits, revenue,data, use or enjoyment of this or any other associated products - loss or damageindirect, or caused to others due to the defect found, incidental or consequential. This appliesto loss or damage under any legal theory, including negligence and other acts tort, breach ofcontract, express or implied warranty and strict liability.4) Assistance under warranty will be performed only if the defective product will be presentedwithin the time provided by law together with the sales invoice or receipt for tax purposes inoriginal.5) The Telcom S.p.A. reserves the right to refuse intervention guarantees the absence of suchdocuments.6) This guarantee will cease if the indication of the model or serial number reported on the producthave been modified, deleted, removed or made illegible.7) This warranty does not cover the costs and risks associated with the transportation of yourproduct to Telcom S.p.A.Are excluded from this Warranty:a) The expression of periodic maintenance and repair or replacement of parts due to wear andwear;b) damage or defects resulting from use, improper handling or use of the product for purposesother thannormal, ie that given in the instruction manual or technical manual;c) damage by misuse of the product, misuse BREAKFAST:
incorrect installation or use of the product for purposes other than those provided or failure tocomply with instructionsTelcom S.p.A. the installation and use;
improper maintenance of the product, not in accordance with the instructions Telcom SpA thecorrectmaintenance;
installation or use of the product does not comply with technical standards and safety in thecountrywhich the product is installed or used, and the rules worked out in the booklet instructions.
WARRANTY
18
ACCESSORI
E/SOFFIANTEA CANALE LATERALE BISTADIO
Completa di silenziatore in aspirazionee mandata e valvola di sicurezza.
E/POMPA DI SOLLEVAMENTO
COMPRESSORE LINEARE A MEMBRANA
Bassa rumorosità Basso consumo
MISCELA BATTERICO ENZIMATICA
Appositamente formulata per l’innesco o ilripristino dell’attività batterica nei sistemidi depurazione biologica di acque reflue.
19
ACCESSORI
TORRETTA Cod. INPOZ 550 GR
dimensioni [cm] L=68, P=68, H=60
POZZETTO GRIGLIATORE Cod. POZ 550 GR
dimensioni [cm] L=68, P=68, H=60
GUARNIZIONEGuarnizione doppio labbro
Cod.: Guarnizione Ø 100 mm Cod.: Guarnizione Ø 125 mm Cod.: Guarnizione Ø 160 mm Cod.: Guarnizione Ø 200 mm Cod.: Guarnizione Ø 250 mm Cod.: Guarnizione Ø 315 mm
POZZETTO GREZZO Cod.: POZ 100GR
Chiusino Ø320 mm dimensioni [cm]: 48x48x75H capacità 100 litri
Cod.: POZ 300GR Chiusino Ø420 mm dimensioni [cm]: 73x73x82H capacità 300 litri
Pozzetto: Per le esigenze impiantistiche è stato realizzato un pozzettomonolitico a otto facce, che trova il suo impiego nella realizzazionedelle diverse soluzioni proposte: esso può fungere da pozzetto diispezione, come pozzetto di confluenza/ripartizione, oppure comepozzetto di manovra. La particolare forma consente con facilità direalizzare il collegamento con direzione a 45° o multipli.
20
Tabella 3Prima Colonna
Tabella 4Tabella 3Seconda
REFERRING TABLES
Attached notes to Tables 3 and 4Annex 5 of Part Three -
D. Lgs. n° 152/06and subsequent modifications:
(*) The limits for discharge into the sewer systemare mandatory in the absence of limits set by thearea or in the absence of a final treatment able tomeet the emission limits the final discharge. Differentlimits set by manager must be made to comply withthe stated in footnote 2 to Table 5 on substancesdangerous.1) For watercourses, the maximum variation betweenaverage temperatures of any section of the coursewater upstream and downstream from the point ofrelease must not exceed 3° C. At least half of anysection downstream such variation shall not exceed1° C. For lakes, the temperature of the exhaustexceed 30 ° C and the temperature is raised. Bodycontainer must not exceed3° C over 50 meters away from the point of release.In the artificial channels, the maximum value averagetemperature of any section must not exceed 35° C,the condition that is conditional on the consent ofthe person who manages the channel. For the seaand the areas of the mouth water courses are notsignificant, the temperature exhaust must not exceed35 ° C and the increase the temperature of thecontainer must not in no case exceed 3 ° C above1000 meters distance from the point of release. Itmust also be ensure environmental compatibility ofthe discharge container with the body and preventedthe formation of thermal barriers at the mouth ofthe rivers.2) As for waste water discharges the urban limitsare indicated in Table 1 and, for sensitive areas,including those in Table 2. As Concerning the dischargeof industrial waste water with destination to sensitiveareas the concentration of total phosphorus and totalnitrogen must be respectively 1 and 10 mg / L.3) These limits do not apply to the discharge intothe sea, in accordingly zones mouth waters aretreated as marine coastal areas, provided that atleast on half of a any section downstream of thedischarge are not disturbed the natural variations inthe concentration of sulfates or chlorides.4) In the authorization of the exhaust for thetreatment of urban waste water by the competentauthority will set the limit appropriate in relationto the environmental situation and health and hygieneof the water body and the receptor practice. Werecommend a limit of no more than 5000 cfu/100mL.5) The toxicity test is required. In addition to theessay on Daphnia magna, may be carried out testsacute toxicity to Ceriodaphnia dubia, Selenastrumcapricornutum, bacteria or organisms bioluminescentisuch as Artemia salina, discharges to water or saltother bodies that will be among those listed underItem 4 of this Annex. In the case of run multipletests to consider the toxicity worst result. The positiveresult of test toxicity does not determine the directapplication of penalties provided for in Title V, alsodetermines the obligation in-depth analyticalinvestigation of the Research the causes of toxicityand their removal.
Saggio di tossicitàacuta (5)
Azoto totaleBerillioVanadio
Composti organiciaromatici totali
Composti organiciazotati totali
Pesticidi totali(esclusi i fosforati)
tra cui:- aldrin
- dieldrin- endrin- isodrin
Solventi clorurati
Escherichia coli (4)
Sostanze
pHTemperatura
Colore
Odore
5 (comeO2)
AlluminioArsenico
BarioBoro
CadmioCromo totale
Cromo VIFerro
ManganeseMercurioNichelPiomboRame
SelenioStagnoZinco
Solfuri (come H S)
3)
CloruriFluoruri
(come NH4)
Grassi e olianimali/vegetali
FenoliAldeidi
Solventi organiciaromatici
Solventi organiciazotati
BOD
COD
Cloro attivo libero
Solfiti (come SO
Solfati (come SO4)
Idrocarburi totali
Tensioattivi totaliPesticidi fosforati
Materiali grossolani
Solidi sospesi totali
Cianuri totali(come CN)
Azoto ammoniacale
Azoto nitroso(come N)
Azoto nitrico(come N)
Fosforo totale(come P)
mg/Lmg/Lmg/L
mg/L
mg/L
mg/L
mg/L
mg/L
mg/Lmg/Lmg/Lmg/Lmg/Lmg/Lmg/Lmg/Lmg/Lmg/Lmg/Lmg/Lmg/Lmg/Lmg/Lmg/L
mg/L
mg/Lmg/L
mg/L
mg/L
mg/Lmg/L
mg/L
mg/L
mg/L
mg/L
mg/L
mg/Lmg/Lmg/L
mg/L
mg/L
mg/Lmg/L
mg/L
mg/Lmg/Lmg/Lmg/Lmg/L
UFC/100mL
≤ 0,01≤ 0,01≤ 0,002≤ 0,002
≤ 1
nota
Unità diMisura Scarico in acque
superficialiScarico in pubblica
fognatura (*)
Reflui cherecapitanosul suolo
6-810
Assenti
25
20
100
10,05100,5
1 -
20,2
0,20,10,1
0,0023
0,5
0,20,5
0,5
500
2001
2
5
0,10,5
0,5
diluizione 1:20
Non deve esserecausa di molestie
Assenti
≤ 80
≤ 40
≤ 160
≤ 1≤ 0,5≤ 20≤ 2
≤ 0,02≤ 2
≤ 0,2≤ 2≤ 2
≤ 0,005≤ 2
≤ 0,2≤ 0,1≤ 0,03≤ 10≤ 0,5
≤ 0,5
≤ 0,2≤ 1
≤ 1
≤ 1000
≤ 1200
≤ 6
≤ 10
≤ 15
≤ 0,6
≤ 20
≤ 20
≤ 5≤ 0,5≤ 1
≤ 0,2
≤ 0,1
≤ 2≤ 0,10
≤ 0,05
diluizione 1:40
Non deve esserecausa di molestie
assenti
≤ 200
≤ 250
≤ 500
≤ 2,0≤ 0,5
-≤ 4
≤ 0,02≤ 4
≤ 0,20≤ 4≤ 4
≤ 0,005≤ 4
≤ 0,3≤ 0,4≤ 0,03
-≤ 1,0
≤ 1,0
≤ 0,3≤ 2
≤ 2
≤ 1000
≤ 1200
≤ 12
≤ 10
≤ 30
≤ 0,6
≤ 30
≤ 40
≤ 10≤ 1≤ 2
≤ 0,4
≤ 0,2
≤ 4≤ 0,10
≤ 0,05
≤ 0,01≤ 0,01≤ 0,002≤ 0,002
≤ 2
5,5 – 9,5
Non percettibile con Non percettibile con
- nota
150,10,1
0,01
0,01
Il campione non èaccettabile quando,dopo 24 ore, il numerod e g l i o r g a n i s m iimmobili è uguale omaggiore del 50% deltotale.
Il campione non èaccettabile quando,dopo 24 ore, il numerod e g l i o r g a n i s m iimmobili è uguale omaggiore del 80% deltotale.
Il campione non èaccettabile quando,dopo 24 ore, il numerod e g l i o r g a n i s m iimmobili è uguale omaggiore del 50% deltotale.
5,5 – 9,5SAR
2
0,01
(1) (1)
(2) (2)
(comeO2)(2) (2)
(2) (2)
(3) (3)
(3) (3)
(2) (2)
(2) (2)
(2) (2)
(2) (2)
(4) (4)
(5) (5)
(5) (5)
Attached notes to Tables 3 and 4 Annex 5 of Part Three -D. Lgs. n° 152/06 and subsequent modifications:
21
REFERRING CONTACT PERSON
THE MANUFACTURER RESERVES THE RIGHT TO MAKE CHANGES AND/OR IMPROVEMENTS IN DESIGNS &DIMENSIONS WITHOUT NOTICE AND WITHOUT INCURRING OBLIGATION. THE MEASURES OF SPACE AREEXPRESSED IN CENTIMETERS WITH TOLERANCE OF ± 1%, HAVE THE CAPACITY TOLERANCE ± 10%.
Technological innovationand cutting-edge choiches
We were the first to realize the potential ofrotational, to become leaders industry with 19 plantsCarousel, 450 employees, plants in Europe, America,Asia for an extension total of 54 000 m2 covered.Industrial and innovative technologies are integralpart of our way of doing business. But the decisivefactor of our business success is the love for ourwork, with great passion which our staff followedall the steps of production process, from creationto print hand finishing of products. We have awarehouse of the largest in the world, with over 20000 m2 covered and a simultaneous capacity loadequal to eighteen trucks. We have establishedbusiness contacts in the five continents and multiplejoint ventures. Experience and a solid foundation togrow.
ISO 9001 / 14001 Certified Company
The ISO 9000 and ISO 14000 standards are whichvoluntary organizations can choose to join, andproviding a set of criteria to be met, the order toseek and ensure that its actions in field of qualitymanagement (ISO 9001) and environmental (ISO14001) is in compliance with stricter operationalprocedures. Companies that choose to adhere tothese rules volunteers are screened on a regularbasis by a third entity certificate, which guaranteesthe conformity of these systems managementstandards international. Adherence to these standardsensures a supply side certain qualitative anddocumented, and a production compatible, from anenvironmental point of view, with the territory. ISO9001 and 14001 identify the seriousness and qualityTelcom acquired in thirty years of experience.Obtaining the certification UNI EN ISO 14001 is anofficial recognition of the policy respect of theterritory sought by Telcom SpA and is a constantincentive to improve.
Light weight and shockproof
Recyclables Materials
Heat and frost resistant
Resistent to every weather conditions
Easy to install
Easier storage and transport
Good Value: best ratio price/duration.
7 GOOD REASONS TO CHOSETHERMOPLASTIC WASTE-WATER
TREATEMENT SYSTEMS
QUALITY AND CERTIFICATIONS