ECE R112 & R123 Conditions on the luminous flux of light ...The power consumption of the LED system...

20
ECE R112 & R123 - Conditions on the luminous flux of light sources 21/10/2014 Rapport EPI 1

Transcript of ECE R112 & R123 Conditions on the luminous flux of light ...The power consumption of the LED system...

Page 1: ECE R112 & R123 Conditions on the luminous flux of light ...The power consumption of the LED system is lower. • The minimum threshold of the luminous flux for LED modules required

ECE R112 & R123

-

Conditions on the luminous flux

of light sources

21/10/2014 Rapport EPI 1

Glukhenkiy
Text Box
Transmitted by the expert from France
Glukhenkiy
Text Box
Informal document GRE-72-25 (72nd GRE, 20-22 October 2014, agenda item 4 (i) (iv))
Page 2: ECE R112 & R123 Conditions on the luminous flux of light ...The power consumption of the LED system is lower. • The minimum threshold of the luminous flux for LED modules required

• To show that the provisions § 5.3.2.3 of Regulation R112 and §5.1.4 in R123 are useless.

• These prescriptions required a minimum luminous flux of 1000 lumen for the LED modules contributing to the principal Low beam.

• We compare the optical efficiency and the power consumption of LED LB (less than 1000 lm on the source) with two halogen LB.

Foreword

21/10/2014 GRE 71st

Page 3: ECE R112 & R123 Conditions on the luminous flux of light ...The power consumption of the LED system is lower. • The minimum threshold of the luminous flux for LED modules required

• Basic LB 1 – luminous flux of the LED

Module= 1000 Lm. ~20W

• Basic LB 2 - Luminous flux of the LED

Module = 800 Lm. ~16W

• H7 Reflector– 1500 Lm @ 13.2V. 58W

• H4 Reflector – 1020 Lm @ 13.2 V. 68W

Optical systems

21/10/2014 Nom de la réunion

Page 4: ECE R112 & R123 Conditions on the luminous flux of light ...The power consumption of the LED system is lower. • The minimum threshold of the luminous flux for LED modules required

What the driver sees

21/10/2014 Nom de la réunion

Page 5: ECE R112 & R123 Conditions on the luminous flux of light ...The power consumption of the LED system is lower. • The minimum threshold of the luminous flux for LED modules required

Basic LB 1 - Initial LED 1000 lm

21/10/2014 Nom de la réunion

Page 6: ECE R112 & R123 Conditions on the luminous flux of light ...The power consumption of the LED system is lower. • The minimum threshold of the luminous flux for LED modules required

Basic LB 2 - Reduced LED 800 lm

21/10/2014 Nom de la réunion

Page 7: ECE R112 & R123 Conditions on the luminous flux of light ...The power consumption of the LED system is lower. • The minimum threshold of the luminous flux for LED modules required

H7 LB Reflector - @13.2V

21/10/2014 Nom de la réunion

Page 8: ECE R112 & R123 Conditions on the luminous flux of light ...The power consumption of the LED system is lower. • The minimum threshold of the luminous flux for LED modules required

H4 LB Reflector - @13.2V

21/10/2014 Nom de la réunion

Page 9: ECE R112 & R123 Conditions on the luminous flux of light ...The power consumption of the LED system is lower. • The minimum threshold of the luminous flux for LED modules required

Bird’s eye view

21/10/2014 Nom de la réunion

Page 10: ECE R112 & R123 Conditions on the luminous flux of light ...The power consumption of the LED system is lower. • The minimum threshold of the luminous flux for LED modules required

Illumination on the road LED - 1000 lm LED - 800 lm H7 Reflector H4 Reflector

180m

90m

Page 11: ECE R112 & R123 Conditions on the luminous flux of light ...The power consumption of the LED system is lower. • The minimum threshold of the luminous flux for LED modules required

Synthesis

21/10/2014 Nom de la réunion

Page 12: ECE R112 & R123 Conditions on the luminous flux of light ...The power consumption of the LED system is lower. • The minimum threshold of the luminous flux for LED modules required

GRE Session March April 2014

• During the previous session (71st session) , this proposal was presented as two Informal documents by France. – 71/09 and 71/10.

• Some contracting parties were reluctant to adopt such a proposal: – Possibility to design a compliant beam with

patches on the road

– Risk of low flux on the road.

• France proposes new formal documents taking into account these comments. – TRANS/WP29/GRE/2014/35 and 2014/36.

Page 13: ECE R112 & R123 Conditions on the luminous flux of light ...The power consumption of the LED system is lower. • The minimum threshold of the luminous flux for LED modules required

Characteristics of a safe low beam

• No glare.

• Good visibility distance.

• Good road illumination on the road between

25m and 50 m.

• Good width of the beam pattern.

• Not too much light on the foreground.

• Enough light on the landscape.

Page 14: ECE R112 & R123 Conditions on the luminous flux of light ...The power consumption of the LED system is lower. • The minimum threshold of the luminous flux for LED modules required

Current requirement of the regulation. (R112)

30°

Areas where the light distribution is already under control by R112.

30°

No glare zone under control by R112.

Page 15: ECE R112 & R123 Conditions on the luminous flux of light ...The power consumption of the LED system is lower. • The minimum threshold of the luminous flux for LED modules required

Requirement of the regulation, on the road

Range/visibility distance 50 – 75 m and beyond Illumination of the road

25- 50 m

Width of the beam pattern 25 m

Light on the foreground

Page 16: ECE R112 & R123 Conditions on the luminous flux of light ...The power consumption of the LED system is lower. • The minimum threshold of the luminous flux for LED modules required

Characteristics of a safe low-beam

• No glare: OK.

• Good visibility distance: OK.

• Good road illumination on the road between

25m and 50 m: OK.

• Good width of the beam pattern: OK.

• Not too much light on the foreground : OK

• Enough light on the landscape: Not covered

by the regulation.

Page 17: ECE R112 & R123 Conditions on the luminous flux of light ...The power consumption of the LED system is lower. • The minimum threshold of the luminous flux for LED modules required

Requirement of the regulation with modification

Along the line 25L-25R I > 1700 cd

30°

Flux in the area: 30L 30R / 0°D 10°D

Areas where the light distribution is already under control by R112.

30°

Page 18: ECE R112 & R123 Conditions on the luminous flux of light ...The power consumption of the LED system is lower. • The minimum threshold of the luminous flux for LED modules required

Requirement of the regulation with modification, on the road

Range/visibility distance 50 – 75 m and beyond Illumination of the road

25- 50 m

Width of the beam pattern 25 m

4,25 m

Light on the foreground

Page 19: ECE R112 & R123 Conditions on the luminous flux of light ...The power consumption of the LED system is lower. • The minimum threshold of the luminous flux for LED modules required

Characteristics of a safe low beam

• No glare: OK

• Good visibility distance: OK

• Good road illumination on the road between

25m and 50 m: OK

• Good width of the beam pattern: OK and

improved

• Enough light on the landscape: Controlled by

the regulation: OK.

Page 20: ECE R112 & R123 Conditions on the luminous flux of light ...The power consumption of the LED system is lower. • The minimum threshold of the luminous flux for LED modules required

Conclusion

• The optical efficiency of a LED systems is better than that of a Halogen

(60% versus 35%).

• The visibility distance and the light distribution of LED system with a

luminous flux lower than 1000 lumen are better than or equal to those of

Halogen headlamps.

• The power consumption of the LED system is lower.

• The minimum threshold of the luminous flux for LED modules required in R112 § 5.3.2.3. and R123 §5.1.4 should be removed.

• During the session in March 2014, some Contracting Parties were reluctant

to remove the 1,000Lm because of a risk of low luminous flux on the road

which is covered by new proposals to be discussed.