Issue Date: Valid Until: Reference №: 07 Mar 06 Mar T1128/ Signatory: for P R Di Chief E National Measurement Office | Stanton Avenue Tel +44 (0)20 8943 7272 | Fax +44 (0)20 8943 72 NMO is an Executive Agency of the Departmen EC Type-Approva UK 2707 Revision Issued by the: National Measuremen Notified Body Number In accordance with the re Regulations 2000 (SI 2000 Directive 2009/23/EC, this E NCR Corporation 2651 Satellite Blvd Duluth Georgia 30096 USA In respect of a Class III N 7876-2000 scanner/scale a Max 13.995 kg or Min 0.100 kg e = 0.005 kg The necessary data (princ for identification purposes descriptive annex to this ce This revision replaces earlie rch 2014 rch 2024 /0050 ixon Executive 0135 e | Teddington | TW11 0JZ | United Kingdom 270 | Web www.bis.gov.uk/nmo nt for Business, Innovation & Skills NAWI (indicator) Re al Certificate n 8 nt Office r 0126 equirements of the Non-Automatic Weig 0/3236) which implement, in the United K EC Type-Approval Certificate has been is Non-Automatic Weighing Instrument desi and having the following characteristics: 9.995 kg cipal characteristics, alterations, securing s and conditions (when applicable) are ertificate. er versions of this certificate UK 2707 V(0)a ev. 4 19 February 2013 ghing Instruments Kingdom, Council ssued to: ignated the NCR g, functioning etc) e set out in the

Transcript of EC Type-Approval Certificate UK 2707 Revision · 4 PERIPHERAL DEVICES AND INTERFACES 4.1...

Page 1: EC Type-Approval Certificate UK 2707 Revision · 4 PERIPHERAL DEVICES AND INTERFACES 4.1 Peripherals There are no peripherals approved under this certificate. 4.2 Interfaces-IBM 485

Issue Date: Valid Until: Reference №:

07 March 201406 MarchT1128/005

Signatory: for

P R DixonChief Executive

National Measurement Office | Stanton Avenue | Teddington | TW11 0JZ | United KingdomTel +44 (0)20 8943 7272 | Fax +44 (0)20 8943 7270 | Web NMO is an Executive Agency of the Department for Business, Innovation & Skills

EC Type-Approval CertificateUK 2707 Revision

Issued by the:

National Measurement OfficeNotified Body Number 0126

In accordance with the requirements of the Regulations 2000 (SI 2000Directive 2009/23/EC, this EC

NCR Corporation 2651 Satellite Blvd Duluth Georgia 30096 USA In respect of a Class III N7876-2000 scanner/scale and having the following characteristics:

Max 13.995 kg or Min 0.100 kg e = 0.005 kg

The necessary data (principal characteristics, alterations, securing, for identification purposes and conditions (when applicable) are set out in the descriptive annex to this certificate.

This revision replaces earlier versions of this

March 2014 March 2024

/0050

P R Dixon Chief Executive

0135

National Measurement Office | Stanton Avenue | Teddington | TW11 0JZ | United Kingdom Tel +44 (0)20 8943 7272 | Fax +44 (0)20 8943 7270 | Web www.bis.gov.uk/nmo

an Executive Agency of the Department for Business, Innovation & Skills NAWI (indicator) Rev. 4

Approval Certificate Revision 8

National Measurement Office Notified Body Number 0126

In accordance with the requirements of the Non-Automatic Weighing0/3236) which implement, in the United Kingdom, Council

/EC, this EC Type-Approval Certificate has been issued to:

Non-Automatic Weighing Instrument designated the and having the following characteristics:

9.995 kg

The necessary data (principal characteristics, alterations, securing, for identification purposes and conditions (when applicable) are set out in the descriptive annex to this certificate.

This revision replaces earlier versions of this certificate

UK 2707

V(0)a

(indicator) Rev. 4 19 February 2013

utomatic Weighing Instruments ) which implement, in the United Kingdom, Council

has been issued to:

nstrument designated the NCR

The necessary data (principal characteristics, alterations, securing, functioning etc) for identification purposes and conditions (when applicable) are set out in the

Page 2: EC Type-Approval Certificate UK 2707 Revision · 4 PERIPHERAL DEVICES AND INTERFACES 4.1 Peripherals There are no peripherals approved under this certificate. 4.2 Interfaces-IBM 485

2

Descriptive Annex

1 NAME AND TYPE OF INSTRUMENT

This instrument is an NCR 7876-2000 scanner/scale, Class III, mains operated, self-indicating, weight-only, Non-Automatic Weighing Instrument (Figure 1).

2 DESCRIPTION

2.1 Construction

2.1.1 Mechanical

Main features:

- Designed for flush-mounting in checkout surface, having frame extensions to support the 7876-2000 in the checkout counter.

- Steel framework supporting load cell, barcode scanner and electronics.

- NCR 7825 remote display unit.

- NCR 7876 bar code scanner.

- Interface for POS connection.

- Remote power supply module.

2.1.3 Load cell

The load cell is a Flintec Type SP12-30, or NCR Part № 497-0429309 or 497-0438405.

2.1.4 Power supply

The remote power supply unit is an AcBel model API-8545 NCR P/N 497-0411207 and provides regulated dc voltages of +5 V, +12 V and -12 V to the weighing modules and to the bar code scanner.

2.1.4 Analogue circuitry

The analogue signal from the load cell is amplified, filtered and digitised.

2.1.5 Digital circuitry

Main features:

- Computational values from the EEPROM and weight data and from the scale board are processed by a micro-computer (5802965SA50) for continuous weight display and upon request, transmission of weight to the POS/PC terminal.

- EEPROM contains configuration data including span, zero and linearity settings.

Page 3: EC Type-Approval Certificate UK 2707 Revision · 4 PERIPHERAL DEVICES AND INTERFACES 4.1 Peripherals There are no peripherals approved under this certificate. 4.2 Interfaces-IBM 485

3

2.1.6 Display

The weight display is provided by either a dual or single head NCR 7825 remote display. The display consists of an LCD panel with seven segments, each 9.5 mm high. The two digits furthest to the right are used to show the unit of weight (Figure 2).

2.2 Operation

Main features:

- Upon power up, diagnostic routines are run to check the correct functioning of the instrument.

- Before display or transmission to the POS interface, the weight data is checked for stability. Stability is considered to have been achieved if the previous two readings are within ±0.2 e of the present reading. The instrument is then only considered to be unstable if the difference between the present reading and the previous reading becomes greater than 1 e.

- Digital hysteresis is applied to reduce display flicker, and adds or subtracts 0.1 e depending on the direction of weighing.

- Automatic zero tracking occurs at gross zero indicated weight, and is only applied over the balance range of 4% of capacity.

3 TECHNICAL DATA

3.1 Technical characteristics

3.1.1 Power supply 110-120 V or 220-240 V ac 50/60 Hz.

4 PERIPHERAL DEVICES AND INTERFACES

4.1 Peripherals

There are no peripherals approved under this certificate.

4.2 Interfaces

- IBM 485 - USB - RS 232 - ICL MDL

4.2.1 Using the above mentioned interfaces the non-automatic weighing instrument may be connected to any compatible point of sale device (POS) if the device has a Test Certificate issued by a Notified Body appointed to certify instruments according to paragraph 1 of annex II of the EC Directive 2009/23/EC on Non-Automatic Weighing Instruments.

Page 4: EC Type-Approval Certificate UK 2707 Revision · 4 PERIPHERAL DEVICES AND INTERFACES 4.1 Peripherals There are no peripherals approved under this certificate. 4.2 Interfaces-IBM 485

4

5 APPROVAL CONDITIONS

This certificate is issued subject to the following conditions:

5.1 Legends and Inscriptions

5.1.1 The instrument and remote display bears the following legends:

Max Min e = Class III

5.1.2 The instrument shall bear the following legends:

CE marking Verification mark Green M Serial number Manufacturers mark or name Certificate number Special temperature limits (10 ºC to 40 ºC)

The markings and inscriptions shall fulfil the requirements of Paragraph 1 of Annex IV of the Directive 2009/23/EC.

6 LOCATION OF SEALS

6.1 A lead wire or paper seal is used to secure a cover protecting the calibration switch, which is housed in a compartment underneath the load receptor (Figure 3).

6.2 A 30 mm x 30 mm adhesive plate is provided for an inspector's mark.

Components that may not be dismantled or adjusted by the user will be secured by either a wire and lead seal or tamper evident label and securing mark. The securing mark may be either:

- a mark of the manufacturer and/or manufacturer’s representative, or - an official mark of a verification officer.

7 LOCATION OF CE MARKING

The CE marking is located on the data plate. The data plate is placed on the right front support flange (Figure 4).

Page 5: EC Type-Approval Certificate UK 2707 Revision · 4 PERIPHERAL DEVICES AND INTERFACES 4.1 Peripherals There are no peripherals approved under this certificate. 4.2 Interfaces-IBM 485

5

8 ALTERNATIVES

8.1 Having an extended weighing receptor attachment. An additional vertical weighing receptor constructed from stainless steel and glass is attached to the sub platter. The vertical weighing receptor is part of the “live” weight receptor and enables oversized goods to be weighed (Figure 5).

8.2 Having the 7876-8000 scanner scale, the 7876-8000 has the same component parts as the 7876-2000. In addition, the sub-platter and framework have been lowered to accommodate a Sensormatic Electronic Article Surveillance (EAS) security tag deactivation antenna that may be fitted underneath the load receptor (Figure 6).

8.3 Having the 7876-5000 scanner scale, the 7876-5000 has the same component parts as the 7876-2000 except it has a shorter base container section being 39.4 cm long (Figure 7).

8.4 An additional vertical weighing receptor constructed from plastic and glass is attached to the sub platter. The vertical weighing receptor is part of the “live” weight receptor and enables oversized goods to be weighed (Figure 8).

8.5 Having a different rear plastic tower (Figure 9) with a window to allow a retailer to add a logo. The framework and the mounting of the main circuit board are slightly modified, and there is a new section added to the rear to house optics.

8.6 Having the data plate placed on the H-bar (scale load receiving element) and visible through the clear plastic contamination plate (Figure 10).

8.7 An alternative gross, primary, live weight indication may also be provided on the NCR 7401, NCR 7402, NCR 7342, NCR 7343 or NCR 7346 touch screen display with weight information conforming to the minimal numeric height requirements of 9.5 mm and the "kg" unit indication. Also the Max, Min and e = information must be shown near the weight indication.

8.8 An alternative gross, primary, live weight indication may also be provided on the NCR 7456 or NCR 7457 using a Customer’s Information Display (CID) which is a CRT or Flat Screen Monitor with weight information conforming to the minimal numeric height requirements of 9.5 mm and the "kg" unit indication. Also the Max, Min and e = information must be shown near the weight indication.

9 ILLUSTRATIONS

Figure 1 7876-2000 scanner/scale Figure 2 NCR 7825 dual and single head remote display Figure 3 Location of seal Figure 4 Location of data plate Figure 5 Extended weighing receptor attachment Figure 6 7876-8000 scanner scale with Sensormatic EAS security tag

deactivation antenna Figure 7 7876-5000 scanner/scale Figure 8 Extended plastic weighing receptor attachment Figure 9 Alternative rear tower and framework Figure 10 Alternative location of data plate

Page 6: EC Type-Approval Certificate UK 2707 Revision · 4 PERIPHERAL DEVICES AND INTERFACES 4.1 Peripherals There are no peripherals approved under this certificate. 4.2 Interfaces-IBM 485

6

CERTIFICATE HISTORY

Issue № Date Description

UK 2707 22 March 2004 Type approval first issued.

UK 2707 Revision 1 11 June 2004 Creation of Section 8.1.

UK 2707 Revision 2 16 June 2004 Creation of Section 8.2.

UK 2707 Revision 3 27 October 2004 Creation of Section 8.3 and 8.4.

UK 2707 Revision 4 18 March 2005 Creation of Section 8.5.

UK 2707 Revision 5 21 October 2005 Creation of Section 8.6.

UK 2707 Revision 6 24 March 2006 Creation of Section 8.7.

UK 2707 Revision 7 18 May 2006 Creation of Section 8.8. Addition of NCR 7346 to Section 8.7.

UK 2707 Revision 8 07 March 2014 Certificate renewed for a further 10 years.

Page 7: EC Type-Approval Certificate UK 2707 Revision · 4 PERIPHERAL DEVICES AND INTERFACES 4.1 Peripherals There are no peripherals approved under this certificate. 4.2 Interfaces-IBM 485

7

Figure 1 7876-2000 scanner/scale

Figure 2 NCR 7825 dual and single head remote display

Page 8: EC Type-Approval Certificate UK 2707 Revision · 4 PERIPHERAL DEVICES AND INTERFACES 4.1 Peripherals There are no peripherals approved under this certificate. 4.2 Interfaces-IBM 485

8

Figure 3 Location of seal

Figure 4 Location of data plate

Page 9: EC Type-Approval Certificate UK 2707 Revision · 4 PERIPHERAL DEVICES AND INTERFACES 4.1 Peripherals There are no peripherals approved under this certificate. 4.2 Interfaces-IBM 485

9

Figure 5 Extended weighing receptor attachment

Figure 6 7876-8000 scanner scale with Sensormatic EAS security tag deactivation antenna

Page 10: EC Type-Approval Certificate UK 2707 Revision · 4 PERIPHERAL DEVICES AND INTERFACES 4.1 Peripherals There are no peripherals approved under this certificate. 4.2 Interfaces-IBM 485

Figure 7

10

Figure 7 7876-5000 scanner/scale

39.4 cm long

39.4 cm long

Page 11: EC Type-Approval Certificate UK 2707 Revision · 4 PERIPHERAL DEVICES AND INTERFACES 4.1 Peripherals There are no peripherals approved under this certificate. 4.2 Interfaces-IBM 485

11

Figure 8 Extended plastic weighing receptor attachment

Page 12: EC Type-Approval Certificate UK 2707 Revision · 4 PERIPHERAL DEVICES AND INTERFACES 4.1 Peripherals There are no peripherals approved under this certificate. 4.2 Interfaces-IBM 485

Figure 9

Figure 10

Crown Copyright 2014 NATIONAL WEIGHTS AND MEASURES LABORATORYDepartment for Business, Innovation & Skills

12

9 Alternative rear tower and framework

Figure 10 Alternative location of data plate

NATIONAL WEIGHTS AND MEASURES LABORATORY for Business, Innovation & Skills