Dynatel Diagnostic Testing...

28
269 269 Test, Measurement and Facilities Locating 3 Dynatel Diagnostic Testing Equipment Subscriber Loop Products 900 Series 270 Subscriber Loop Tester 946DSP 279 Qualification Test Sets 949 and 950 ADSL 284 Advanced Modular System 965AMS 288 How to Search this Catalog This digital catalog provides you with two quick ways to find the products and information you’re looking for. Just point and click on the bookmarks to the left or the labeled sections of the table of contents. You can also use the “search” function built into Adobe Acrobat to jump directly to any text reference in this document. Acrobat “Search” function instructions: 1. Press CONTROL + F 2. When the dialog box appears, type in the word or words you are looking for and press ENTER. 3. Depending on your version of Acrobat, it will either take you directly to the first instance found, or display a list of pages where the text can be found. In the latter, click on the link to the pages provided. How to Search the 3M Website 3M Solutions Tool The solutions tool is designed to show you the breadth of the 3M product line and allow you to drill into specific categories to identify solutions. To use this free Internet support tool, visit: http://www.3M.com/Telecom.

Transcript of Dynatel Diagnostic Testing...

Page 1: Dynatel Diagnostic Testing Equipmentmultimedia.3m.com/mws/media/357585O/3m-test-and-measurement... · Dynatel™ Diagnostic Testing Equipment ... enhance technician productivity by

269269

Test, Measurement and Facilities Locating

3Dynatel™ Diagnostic Testing Equipment

Subscriber Loop Products 900 Series 270

Subscriber Loop Tester 946DSP 279

Qualification Test Sets 949 and 950 ADSL 284

Advanced Modular System 965AMS 288

How to Search this CatalogThis digital catalog provides you with two quick ways to find the products and information you’re looking for. Just point and click on the bookmarks to the left or the labeled sections of the table of contents. You can also use the “search” function built into Adobe Acrobat to jump directly to any textreference in this document.

Acrobat “Search” function instructions:1. Press CONTROL + F2. When the dialog box appears, type in the word or words you are

looking for and press ENTER.3. Depending on your version of Acrobat, it will either take you directly

to the first instance found, or display a list of pages where the text can be found. In the latter, click on the link to the pages provided.

How to Search the 3M Website3M Solutions ToolThe solutions tool is designed to show you the breadth of the 3M product lineand allow you to drill into specific categories to identify solutions. To use this free Internet support tool, visit: http://www.3M.com/Telecom.

Page 2: Dynatel Diagnostic Testing Equipmentmultimedia.3m.com/mws/media/357585O/3m-test-and-measurement... · Dynatel™ Diagnostic Testing Equipment ... enhance technician productivity by

270 www.3MTelecommunications.com 800-426-8688

3M™ Dynatel™ Subscriber Loop Test Products900 Series

Rugged and portable for harsh environments, Dynatel 900 series test sets offer the right mix of

functions, from loop diagnostic routines to fault locating, transmission testing and combination

test/terminal capabilities.

Subscriber Loop Analyzer965DSP

The 965DSP analyzer is a microprocessor-controlled integrated test set that provides full-

featured POTS, wideband and DSL-specific testing. The functions include fault location and

repair verification on twisted-pair and drop cables (utilizing capacitance bridge, resistance

bridge and Time Domain Reflectometer (TDR) functions).

The 965DSP analyzer executes a wide range of individual tests, or performs automatic test

routines to categorize and sectionalize problems. The hand-held set is housed in a lightweight,

ergonomically designed case for portability and ease of handling. It is weather-resistant and

weighs only 4.3 pounds (1.95 kg) with battery, test leads and soft case.

Page 3: Dynatel Diagnostic Testing Equipmentmultimedia.3m.com/mws/media/357585O/3m-test-and-measurement... · Dynatel™ Diagnostic Testing Equipment ... enhance technician productivity by

271

Test, M

easure

ment a

nd

Facilitie

s L

ocatin

g —

Dia

gnostic

Testin

g E

quip

ment

PRODUCT REFERRAL GENERATOR

Accessories and Replacement Parts . . . . . . . . . . pg. 282

Subscriber Loop Analyzer965DSP/SA

The 965DSP/SA subscriber loop analyzer delivers all the

multi-function capabilities of the 965DSP tester and provides a

spectrum analyzer and E, F and G noise-weighted filters. Wideband

noise measurements are made with the E (ISDN/ISDL), F (HDSL) and G

(ADSL) filters. The spectrum analyzer test function enables the

operator to view the DSL frequency spectrum and identify spectral

interferers such as crosstalk noise generated by other services.

Subscriber Loop Analyzers965DSP/ADSL and 965DSP/SA/ADSL

The 965DSP/ADSL and 965DSP/SA/ADSL subscriber loop analyzers

feature an Alcatel™ MTK-20150 modem chipset in the proven 965DSP

platform. The 965DSP/ADSL tester provides active ADSL testing to

address the growing number of residential and business ADSL

customers. It delivers all the multi-function capabilities of the 965DSP

tester plus the testing functions of the ADSL modem.

The 965DSP/SA/ADSL test set adds comprehensive DSL parametric

measurements to this integrated solution. Extended loss measurement

ranges, spectrum analyzer and E, F and G filtered wideband noise

measurements complete this comprehensive family of rugged

loop testers.

The units are weather resistant and weigh only three pounds (4.5 lbs.

with test leads and soft case). Preserving the rugged dependability of

all Dynatel products, the ADSL option incorporates a durable “spacer”

element to the current 965DSP molded plastic case to permit easy and

robust expansion of the ADSL circuit board.

Far End Device II

Designed to provide remote controlled far end testing assistance

during subscriber loop testing, the far end device II is a companion to the

Dynatel 965DSP family of subscriber loop analyzers where the “one

person out” concept has been implemented. The FED device can

enhance technician productivity by connecting to the far end of a cable

pair to enable diagnostic testing from the near end using the DTMF

signaling capability of the 965DSP, 965DSP/SA, 965DSP/ADSL and

965DSP/SA/ADSL test sets.

3M™ DYNATEL™ SUBSCRIBER LOOP TEST PRODUCTS 900 SERIES

Page 4: Dynatel Diagnostic Testing Equipmentmultimedia.3m.com/mws/media/357585O/3m-test-and-measurement... · Dynatel™ Diagnostic Testing Equipment ... enhance technician productivity by

272

Subscriber Loop Tester 945DSP

The Dynatel 945DSP subscriber loop tester is a microprocessor-

controlled test set that provides full-featured POTS testing. The tester

performs a wide range of voice band tests to analyze problems on

twisted-pair cables. Weather-resistant and weighing only 1 pound,

the hand-held 945DSP test set is housed in a lightweight case for

portability and ease of handling.

KIT CONTENTS

SUBSCRIBER LOOP TEST PRODUCTS 900 SERIES

PRODUCT DESCRIPTION 965DSP 965DSP/SA 965DSP/ADSL 965DSP/SA/ADSL 945DSP

Standard Accessories

Analyzer • • • • •

Nickel metal hydride battery pack • • • •

AC adapter • • • •

Specified test cables • • • • •

Alkaline battery holder • • • •

Conductor strap • • • •

Wire gauge • • • •

Self-test circuit board • • • •

Instruction manual • • • • •

ADSL modem Optional Optional • •

Spectrum analyzer Optional • Optional •

Specified batteries 4 alkaline AA

1030 conductor gauge 054007-31253 054007-31253 054007-31253 054007-31253 054007-31253

Alkaline battery holder/adapter 051138-57685 051138-57685 051138-57685 051138-57685 —

110/220 VAC adapter 051138-58628 051138-58628 051138-58628 051138-58628 —

Softcase (model 1151) 051138-87178 051138-87178 051138-87178 051138-87178 051141-04458

Nickel metal hydride battery pack 051138-57686 051138-57686 051138-57686 051138-57686 —

1144 black/red test lead, 051138-57648 051138-57648 051138-57648 051138-57648 051138-57648alligator, bed-of-nails

1142 blue/yellow test lead, 051138-57649 051138-57649 051138-57649 051138-57649 —alligator, bed-of-nails

1143 green test lead, 051138-57650 051138-57650 051138-57650 051138-57650 051138-57650alligator, bed-of-nails

Shorting strap, alligator 051138-58529 051138-58529 051138-58529 051138-58529 —

Optional Accessories

Black/red test lead, 4 mm banana 051138-57608 051138-57608 051138-57608 051138-57608 —

Blue/yellow test lead, 4mm banana 051138-57610 051138-57610 051138-57610 051138-57610 —

Green test lead, 4mm banana 051138-57612 051138-57612 051138-57612 051138-57612 —

Shorting strap, 4 mm banana 051138-58532 051138-58532 051138-58532 051138-58532 —

Video training tape 054007-71941 — — — —

Cigarette lighter adapter 051138-57744 051138-57744 051138-57744 051138-57744 —

IR adapter cable 051138-58764 051138-58764 051138-58764 051138-58764 —

Far End Device FED II 1342 with alligator clips 051138-87639 051138-87639 051138-87639 051138-87639 —

Far End Device FED II 1343 051138-87640 051138-87640 051138-87640 051138-87640 —(bed-of-nails test clips)

Far End Device FED II 1344 (single needle) 051138-89794 051138-89794 051138-89794 051138-89794 —

3M™ DYNATEL™ SUBSCRIBER LOOP TEST PRODUCTS 900 SERIES

Page 5: Dynatel Diagnostic Testing Equipmentmultimedia.3m.com/mws/media/357585O/3m-test-and-measurement... · Dynatel™ Diagnostic Testing Equipment ... enhance technician productivity by

273

Test, M

easure

ment a

nd

Facilitie

s L

ocatin

g —

Dia

gnostic

Testin

g E

quip

ment

FEATURES

3M™ DYNATEL™ SUBSCRIBER LOOP TEST PRODUCTS 900 SERIES

FEATURES 965DSP 965DSP-B 965DSP/SA 965DSP/ADSL 965DSP/SA/ADSL 945DSP

Resistance fault locate • • • • •

Open fault locate • • • • • •

Load coil count • • • • • Optional

Longitudinal balance • • • • • •

Caller Identification (CID) • • • • •

Split fault locate • • • •

Voltage measurement • • • • • •

Tone source • • • • • •

Current measurement • • • • • •

Ohms measurement • • • • • •

Soak test • • • • • •

Ohms-to-distance conversion • • • • •

Loss measurement • • • • • •

Noise measurement • • • • • •

Ringers count • • • • • Optional

Self-test and self-calibration • • • • •

Wideband noise/loss for • •ISDN and xDSL

Line prequalification tests for • • • • •basic rate ISDN service

TDR • • • •

IR port (communication port) • • • • •

Stored results internal memory • • • • •

Communications craft set • • • • •

Measurement units Feet, meters, Feet, meters, Feet, meters, Feet, meters, Feet, meters, Feet, meters,Fahrenheit, Fahrenheit, Fahrenheit, Fahrenheit, Fahrenheit, Fahrenheit,

Celsius Celsius Celsius Celsius Celsius Celsius

Graphic display (backlit) • • • • • •

Auto diagnostic DC testing (loop) • • • • •

Auto diagnostic AC testing • • • • •(transmission)

High insulation resistance test • • • • •

Resistance difference and • • • • •loop resistance

Spectrum analyzer Optional • • Optional •(includes E, F, G noise filters)

Fast kick test • • • • •

Onboard operating instructions • • • • •

ADSL active modem testing Optional Optional Optional • •

Page 6: Dynatel Diagnostic Testing Equipmentmultimedia.3m.com/mws/media/357585O/3m-test-and-measurement... · Dynatel™ Diagnostic Testing Equipment ... enhance technician productivity by

274 www.3MTelecommunications.com 800-426-8688

ORDERING INFORMATION

3M™ DYNATEL™ SUBSCRIBER LOOP TEST PRODUCTS 900 SERIES

965DSP-A 965DSP-B 965DSP-A/SA 965DSP-A/ADSL 965DSP-A/SA/ADSL 945DSP

Packaging 1/cs. 1/cs. 1/cs. 1/cs. 1/cs. 1/cs.

Minimum order 1 each 1 each 1 each 1 each 1 each 1 each

Nickel metal hydride batteries, bed-of-nails clips 051138-57603 051138-58643 051138-88358 051115-14490 051115-14488 —

Nickel metal hydride batteries, bed-of-nails clips and 3M DynatelFar End Device 1343 051138-89791 051138-89790 051115-14740 — 051115-18506 —

Nickel metal hydride batteries, bed-of-nails clips and AC/DC chargers — — 051115-16144 — — —

Nickel metal hydride batteries, bed-of-nails clips, AC/DC chargers and1343 far end device — — 051115-16143 — — —

Nickel metal hydride batteries, 4mm banana plugs and multi-language 051138-70088 051138-87781 051138-87782 051115-14492 051115-14493 —

Nickel metal hydride batteries and single-needle clips — — — 051115-14491 051115-14489 —

Bed-of-nails clips/c-message weighting — — — — — 051115-104452

Bed-of-nails clips/c-message weighting,w/ soak, ringers and load count — — — — — 051115-17989

Page 7: Dynatel Diagnostic Testing Equipmentmultimedia.3m.com/mws/media/357585O/3m-test-and-measurement... · Dynatel™ Diagnostic Testing Equipment ... enhance technician productivity by

275

Test, M

easure

ment a

nd

Facilitie

s L

ocatin

g —

Dia

gnostic

Testin

g E

quip

ment

ELECTRICAL SPECIFICATIONS

3M™ DYNATEL™ SUBSCRIBER LOOP ANALYZER 965DSP (A, B AND SA)

MAIN FUNCTIONS RANGE RESOLUTION ACCURACY

Voltage (DC) 0 to 99.9 V 0.1 V 1% ± 0.5 V100 to 300 V 1 V 3%

Voltage (AC) 0 to 99.9 V 0.1 V 1% ± 0.5 V100 to 250 V 1 V 3%

Current 0 to 59.9 mA 0.1 mA 1% ± 0.3 mA60 to 110 mA 0.1 mA 2%

Resistance and soak test 0 to 9999 Ω 1 Ω 1% ± 5 Ωwith CO voltage 0 to 9999 Ω 1 Ω 1% ± 50 Ω

10 k to 99.9 kΩ 0.1 kΩ 1%100 k to 999 kΩ 1 kΩ 3% 1 M to 9.9 MΩ 0.1 MΩ 3% 10 M to 99 MΩ 1 MΩ 5% 100 M to 990 MΩ 10 MΩ 10%

Opens (no noise) 0 to 3,000 ft. (0 to 1000 m) 1 ft. (1 m) 1% ± 3 ft. (1 m)3,000 to 10,000 ft. (1 km to 3 km) 1 ft. (1 m) 3%10,000 to 50,000 ft. (3 km to 15 km) 10 ft. (10 m) 5%50,000 to 100,000 ft. (15 km to 30 km) 100 ft. (100 m) 10%

RFLFault range 0 to 20 MΩ — —Resistance to 0 to 99.99 Ω RTS 0.01 Ω 0.1% of RTS ± 0.01 Ωfault (no noise) 100 to 999.9 Ω RTS 0.1 Ω 0.2% of RTS ± 0.01 Ω

1 kΩ to 7 kΩ RTS 1.0 Ω 1.0% of RTS ± 0.01 Ω

Loss (and frequency)with 600 Ω Zin -40 to +10 dBm, 200 to 20kHz 0.1 dB, 1Hz, 1kHz 0.5 dB, 1%with 135 Ω Zin -50 to +2 dBm, 20 k to 1200 kHz 0.1 dB, kHz 2 dB, 1%

Noise metallic 0 to 50 dBrnc (-90 to -40 dBm0p) 1 dB 2 dB

Noise to ground 40 to 100 dBrnc (-50 to 10 dBm0p) 1 dB 2 dB

Longitudinal balance 0 to 70 dB 1 dB 2 dB70 to 85 dB 1 dB —

Tone outputID 200 to 1000 Hz, fixed level — —Precision - 600 Ω Zout 200 to 9999 Hz, -20 to +1 dBm 1 Hz, 0.1 dB 1% Hz, 0.2 dB

10 k to 19.99 kHz, -20 to +1 dBm 1 Hz, 0.1 dB 2% Hz, 1 dBWideband - 135 Ω Zout 20 k to 1200 kHz, 0 dBm 1 kHz 1 dB

Dial mode DTMF, Pulse — —

TDRUnder typical conditions a 100, 200, 500, 1,000, 2,000 1 ft. (1 m) 0.6% range500 ft bridge tap can be seen 5,000, 10,000, 20,000, 30,000 ft,at 18,000 ft on a 20,000 ft (30, 60, 150, 300, 600, 1,50024 AWG cable. (150 m bridge 3,000, 6,000, 10,000 m)tap at 5500 m on a 6000 m 0.5 mm cable).

Pulse width 5 nS, 34 nS, 235 nS, 1600 nS — Fixed valuesVelocity input 0.50 to 0.99 (150 to 299 m/µs) 0.01 (1 m/µs) —Modes Single trace, dual trace, — —

differential, memory, crosstalk, peak

Auto-tests Same specifications as full tests See above See above

SA Functions (ISDN/IDSL, HDSL, ADSL)

ISDN (2B1Q)Link test Active/inactive — —Error test (US and Canada only) Near-end and far-end block errors 1 block error 1 block errorDSL Loss (and frequency) -75 to +5 dBm, 20 kHz to 1200 kHz 1 dB 1 dBwith 100 Ω or 135 Ω ZinNoise (with E, F, and G filters)Metallic with100 Ω/135 Ω Zin +10/+20/+30 to +90 dBrn 1 dB 2 dBLongitudinal with 10 kΩ Zin +40/+50/+60 to + 120 dBrn 1 dB 2 dB

Wideband Spectrum Analyzer

Range 10 kHz to 1.8 MHz — —5 spans from 120kHz to 2 MHz — —Dynamic range -90 to +10 dBm — —Frequency resolution 1% of span — —Input impedance 135Ω

Page 8: Dynatel Diagnostic Testing Equipmentmultimedia.3m.com/mws/media/357585O/3m-test-and-measurement... · Dynatel™ Diagnostic Testing Equipment ... enhance technician productivity by

276 www.3MTelecommunications.com 800-426-8688

SPECIFICATIONS

3M™ DYNATEL™ SUBSCRIBER LOOP ANALYZER 965DSP (A, B AND SA)

PHYSICAL SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS

Size H x W x D in. (cm) 10.3 x 4.7 x 3.2 (26.2 x 12 x 8.1) Operating temperature 0° to 140°F (-18 to 60°C)

Net weight lbs. (kg) 4.3 (1.95) with battery Storage temperature -40° to 165°F (-40 to 75°C)and soft case

Shipping weight lbs. (kg) 7.8 (3.54) Humidity 0 to 95%, non-condensing

Material GE Xenoy

ACCESSORIES DESCRIPTION

Test leads U.S. – 5 ft. (1.5 m) test leads with 2 mm gold-plated banana plugs on one end and chrome-plated alligator clips on other end (black/red, blue/yellow, green)European – 5 ft. (1.5 m) test leads with 2 mm gold-plated banana plugs on one end and 4 mm gold-plated bananaplugs on other end (black/red, blue/yellow, green)

RFL strap U.S. – 1.5 ft. (0.5 m) with alligator clips on endsEuropean – 1.5 ft. (0.5 m) with banana plugs on ends

AC/DC battery charger 100-250 VAC (50/60 Hz) input; 12 VDC (1 A) output. For charging only. Do not operate when using charger.

Soft case Heavy-duty fabric case for unit and test leads

Battery holder Plastic holder for 6 AA (LR6) batteries

Battery pack Custom 1.5 amp-hour nickel metal hydride

TOOLBOX FUNCTIONS RANGE RESOLUTION ACCURACY

Load coil count 0 to 5 1 ±1

Ohms/distance calculator 0 to 9999 ohms 0.01 Ω —0 to 99999 ft (0 to 30 km) 1 ft (0.1 m) —

Caller ID (U.S. and Canada only) Date, time, number, name — —Carrier level -4 to -32 dBm 1 dBm 2 dBm

Self-calibrate Pass/fail — —

Loop resistance 0 to 99.9 Ω 0.01 Ω 0.1% ± 0.01 Ω100 to 999.9 Ω 0.1 Ω 0.2% ± 0.01 Ω1000 to 7000 Ω 1 Ω 1.0% ± 0.01 Ω

Resistance difference 0 to 99.99 Ω 0.01 Ω 1% of loop resistance ± 0.01 Ω

Ground resistance 5 to 500 Ω 1 Ω 1% ± 1 Ω

K-TestLoop resistance 0 to 7K Ω __ __Fault ratio (Fault Res1) > twice (Fault Res2) __ __Resistance to fault 0 to 99 Ω 0.01 Ω 5%(no noise) 100 to 999 Ω 0.1 Ω 5%

1K to 3.5K Ω 1 Ω 5%

Stored results (Autotest and TDR) 100 results of each, minimum — —

Ringers 0.0 to 4.0 0.1 ringer equivalent General specifications

GENERAL SPECIFICATIONS

Ruggedness Survives 5 ft. (1.5 m) drop in soft case

Water-resistance Splashproof; may be used in light to moderate rain

Standards Meets FCC part 15, class A: Digital Devices for the US, and EN55022 (radiated emissions), EN55024-2 (electrostatic discharge), EN55024-3 (radiated immunity) EN55024-4 (transient immunity) and IEC1010 (product safety) for Europe. Built to ISO9001 certification for manufacturing facilities. Built to Bellcore (Telcordia Technologies) TSY000078 manufacturing methods. Meets UL50 Rain Test.

Language English and multi-languages

Units Feet or meters, Fahrenheit or Celsius, dBrnC or dBm0p, m/uS or Vp

Battery life Rechargeable battery pack, 12 hours typical usage (no backlight), 4 hours typical (with backlight); typical usage defined as 30 minutes on, 30 minutes off

Charging time Minimum 2.5 hours from low to full

Keypad 24-key membrane keypad with tactile feedback

Display in. (cm) 2.5 x 2.5 (74 x 74), 192 by 192 pixel resolution, backlight

Note: Routine calibration is not recommended or required.

Page 9: Dynatel Diagnostic Testing Equipmentmultimedia.3m.com/mws/media/357585O/3m-test-and-measurement... · Dynatel™ Diagnostic Testing Equipment ... enhance technician productivity by

277

Test, M

easure

ment a

nd

Facilitie

s L

ocatin

g —

Dia

gnostic

Testin

g E

quip

ment

SPECIFICATIONS

3M™ DYNATEL™ SUBSCRIBER LOOP ANALYZER 965DSP SERIES WITH ADSL MODEM

PHYSICAL SPECIFICATIONS

Size H x W x D in. (cm) 10.3 x 4.6 x 3.75 (26.2 x 11.7 x 9.5)

Net weight lbs. (kg) with soft case and test leads 4.5 (2)

Shipping weight lbs. (kg) 8 (3.6)

ENVIRONMENTAL SPECIFICATIONS

Operating temperature 0˚ to 140˚ F (-18˚ to 60˚ C)

Storage temperature -40˚ to 165˚ F (-40˚ to 75˚ C)

Humidity 0 to 95%, non-condensing

Vibration Random 3-axis vibration for 20 minutes

Water resistance Meets UL50 Rain Test

Shock 10 drops on corners and sides from 30 in. (without soft case) and 10 drops on corners and sides from 60 in. (with soft case)

Safety IEC950

OPERATIONAL SPECIFICATIONS

Product will incorporate all the features of the 965DSP and/or 965DSP/SA subscriber loop analyzers at the accuracy currently specified for these products (see 965DSP family product documentation). ADSL datalink capability is limited to link synchronization. No ‘PING’ or data application capability is provided. Modem will initiate a connection with the far-end under operator command. Status messages indicating link progress will be returned.

ANSI/ITU standards supported ITU G.992.2 (G.Lite), ITU G.992.1 (G.DMT), ANSI T1.413 Issue 2

ADSL modes ANSI, G.DMT, G.Lite, MultiMode

Reach Designed to synchronize at distances from 0 ft. to 18,000 ft.

Statistics Actual and maximum upstream and downstream connect ratesUpstream and downstream percent used ADSL line capacityUpstream and downstream noise marginUpstream and downstream signal attenuationUpstream and downstream power levelsModem manufacturer identification (ANSI mode only)Upstream and downstream FEC, CRC, and HEC countsAlarm codes including LOS, LOF, LCD and LOMGraphical display of bits-per-bin count for the DMT signal

Operating modes Captured – Modem auto-disconnects from the far-end after statistics gatheredContinuous – Modem gathers statistics for up to ten minutes

Page 10: Dynatel Diagnostic Testing Equipmentmultimedia.3m.com/mws/media/357585O/3m-test-and-measurement... · Dynatel™ Diagnostic Testing Equipment ... enhance technician productivity by

278 www.3MTelecommunications.com 800-426-8688

SPECIFICATIONS

3M™ DYNATEL™ SUBSCRIBER LOOP TESTER 945DSP

MEASUREMENT FUNCTION RANGE RESOLUTION ACCURACY ±

Size H X W X D in. (cm) 7.5 x 4 x 1.5 (19 x 10.2 x 3.8)Cord length ft. (m) 5 (1.5)

Net weight lbs. (kg) 1 (.5)

Shipping weight lbs. (kg) 1.5 (0.7)

Operating temperature -30° to 140° F (-34° to 60° C)

Storage temperature -40° to 140° F (-40° to 60° C)

Relative humidity 0 to 95%

Display in. (cm) 2.25 x 1.25 (5.7 x 3.2)

AC voltage 0 to 75 V 1.0 V ±1 V75 to 250 V 1.0 V ±3 V

DC voltage 0 to ±100 V 1.0 V ±1 V±100 to ±350 V 1.0 V ±3 V

DC current 0 to ±110 mA 1.0 mA ±2 mA

Resistance 0 to 999Ω 1Ω ±5 Ω or 3%1kΩ to 9.9KΩ 100Ω ±3%

10kΩ to 999KΩ 1 kΩ ±3%1MΩ to 9.9MΩ 100kΩ ±3%10MΩ to 30MΩ 1 MΩ ±10%

Noise metallic (with C-message weighting*) 0 to 60 dBrnc 1 dB ±2 dB

Noise to ground (with C-message weighting*) 40 to 100 dBrnc 1 dB ±2 dB

Opens 0-9999 ft. 1 ft. ±20 ft., ±5%10k to 20k ft. 1k ft. ±5%0 to 6000 m 1 m ±6 m, ±5%

Ground resistance 0 – 50 Ohm 1Ω ±3 Ω

Loop loss -50 to +10 dBm 1 dB ±1 dB

Frequency during loss,single frequency only 200 to 5,000 Hz 1 Hz ±3 Hz

Longitudinal balance 0 to 65 dB 1 dB ±2 dB

Tone outputID 577.5 HzPrecision - 600 ΩZout 404,1004,2804Hz 0 ±.5 dBm

Power source 4 - Disposable Alkaline (AA or LR6) but will accept user provided Ni-Cad or NiMH batteries with user provided external charger

Typical battery life Alkalines: 40 hours of typical use, 15 hours continuous

Over voltage protection 450 VDC, 250 VAC Between any leads to protect the internal circuit.

Vibration Random 3-axis vibration at 12.5Grms for 20 minutes

Rain proof/splash proof Meets UL50, rain test

Shock 10 drops on corners and sides from 30 in. without the soft case and 10 drops from 60 in. in soft case

EMI/EMC Meets FCC part 15, Class A: Digital Devices for the US, and EN55022 (radiated emissions), EN55024-2 (electrostatic discharge), EN55024-3 (radiated immunity),

EN55024-4 (transient immunity) and IEC1010 (product safety) for Europe.

Keypad ON/OFF switch, numeric key pads, which also function as the function keys.

Function keys V (voltage), mA (loop current/ground resistance), Ω (resistance/soak test), OPENS, TONE, DB, AUTO Cal. Two non-testing function keys are ‘*’ and ‘#’.

*Psophometric filter is available as a special order.

Page 11: Dynatel Diagnostic Testing Equipmentmultimedia.3m.com/mws/media/357585O/3m-test-and-measurement... · Dynatel™ Diagnostic Testing Equipment ... enhance technician productivity by

279

Test, M

easure

ment a

nd

Facilitie

s L

ocatin

g —

Dia

gnostic

Testin

g E

quip

ment

3M™ DYNATEL™ SUBSCRIBER LOOP TESTER 946DSP

The 946DSP subscriber loop tester has all the features of the current

945DSP tester with the following additions specific to acceptance

testing of new telephone installations:

The ability to count up to 5 load coils, auto-test: V (T,R,Gnd), mA,

Ground Resistance, Ohms (T,R,Gnd), Opens (T,R,Gnd), Load Coil

Count, Noise, PI, LB and Loss (up to 10 frequencies), storage of up to

10 full sets of test results including the ability to review any of the 10

results in the field on the 946DSP, and upload stored results to a PC

using an adapter cable.

FUNCTION DESCRIPTION

Voltage (V) Detects and measures the presence of central office or foreign DC and AC voltages on R-T, R-G and T-G.

Current (mA) Measures DC loop current.

Ground resistance When measuring mA, press the set up key to measure and display the

ground path resistance (when supported by the switch).

Resistance test Measures conductor and insulation resistance up to 30 megohms. Accurate readings in the presence of foreign voltage. Full autoranging.

Insulation soak test Monitors the leakage resistance from the test leads to ground and indicates changes in the insulation resistance over time in the presence of high voltage. Increasing resistance is an indication of a wet fault and decreasing resistance is an indication of oxidation, which is breaking down and becoming more conductive.

Opens Measures the open length of tip, ring or cable pair at distances up to 100,000 ft, (30 km).

Tone Provides 577 Hz ID tone for conductor identification, and 404, 1004 and 2804 Hz precision tones for determining circuit loss.

Loss Measures voiceband loss up to 5KHz, displaying frequency and level.

Noise Measures circuit noise and power influence, and displays calculated balance. C-Message Weighting is used in the U.S. and Canada, and a Psophometric Filter where ITU (CCITT) Standards are used.

Longitudinal balance This test provides active measurement of line balance.

Dial key Allows storage of 10-14 digit numbers for testing of active lines.

Load coils Counts up to 5 load coils on an unterminated pair.

Result summary screen This screen shows the results from last V, mA, Ground Resistance, Ohms, Opens, Load Coil Count, Noise, PI, LB and Loss test in a tabular form for easy analysis. If desired, these results can then be saved to one of 10 result storage locations.

Result storage Storage will be provided for 10 sets of results. Each set will include a 10 digit numeric identifier and the following measurements: V (T-R), V (T-G), V (R-G), mA, Ground Resistance, Ohms (T-R), Ohms (T-G), Ohms (R-G), Open Length (T-R), Open Length (T-G), Open Length (R-G), Load Coil Count, Noise, Power Influence, Longitudinal Balance and Loss at up to 10 different frequencies.

Result review Means will be provided to review any result set on the screen of the 946DSP.

Result upload Results can be uploaded to a PC through the test leads using an adapter and pc software provided with the unit.

Page 12: Dynatel Diagnostic Testing Equipmentmultimedia.3m.com/mws/media/357585O/3m-test-and-measurement... · Dynatel™ Diagnostic Testing Equipment ... enhance technician productivity by

280 www.3MTelecommunications.com 800-426-8688

ELECTRICAL SPECIFICATIONS

3M™ DYNATEL™ SUBSCRIBER LOOP TESTER 946DSP

FUNCTION RANGE RESOLUTION ACCURACY* TEST LEADS

Voltage (AC) 0 to 75 VAC 1 V ±1 V R-T, R-G, T-G

75 to 250 VAC 1 V ±3 V R-T, R-G, T-G

Voltage (DC) 0 to ± 100 V 1 V ±1V R-T, R-G, T-G

±100 to ±350V 1 V ±3V R-T, R-G, T-G

Loop current (DC) 0 to ±110 mA 1 mA ±2m A R-T (Zin = 430 Ω)

Loop resistance 0 to 999 Ω 1Ω ± 5 Ω or 3% R-T, R-G, T-G

Leakage resistance 1kΩ to 9.9kΩ 10 Ω ± 3% R-T, R-G, T-Gand insulation soak 10kΩ to 99.9kΩ 100 Ω ± 3% R-T, R-G, T-G

100kΩ to 999kΩ 1kΩ ± 3% R-T, R-G, T-G1MΩ to 9.9MΩ 100kΩ ± 3% R-T, R-G, T-G10MΩ to 30MΩ 1MΩ ± 10% R-T, R-G, T-G

Loop loss -50 to +10 dBm 1 dB ±1 dB R-T (Zin=600)

200 to 5000 Hz

Noise metallic with 0 to 60 dBrnc 1 dB ±2 dB R-T (Zin=600)C-message weighting**

Noise to ground with 40 to 100 dBrnc 1 dB ±2 dB R and T-G(Zin=100K)C-message weighting**

Opens 0 to 9,999 ft. 1 ft. ± 20 ft. ±5% Ring, tip, mutual

10,000 to 99,999 ft 100ft +/- 5%(0 to 9,999 m) (1 m) ( ± 6m, ±5%)

(10,000 to 30,000m) (100m) (+/- 5%)

Frequency during loss, 200 to 5,000 Hz 1 Hz ±3 Hz R-Tsingle frequency only

Longitudinal balance 0 to 65 dB 1 dB ±2 dB TR-G

Ground resistance 0 to 50 Ω 1 Ω ± 3 Ω

Load coils Count 0,1,2,3,4 or >4 coils +/- 1 coil

Note: First load must be >3000’ from the unit and 3000’ of cable must extend beyond the last load coil for an accurate count

*Percent of reading

**C-message specification has additional frequency dependent tolerance. Refer to “Subscriber Loop Transmission Test Set Specification”, Bell System PUB 55020, January 1982.

OUTPUT FREQUENCY AMPLITUDE ATTACHMENT REMARKS

ID tone 577.5 Hz 8 Vpp R-T Squarewave, interrupted Precision tone 404,1004, 0 ±0.5 dBm R-T 600Ω source, continuous

2804 Hz sinewave. <10%THD

Page 13: Dynatel Diagnostic Testing Equipmentmultimedia.3m.com/mws/media/357585O/3m-test-and-measurement... · Dynatel™ Diagnostic Testing Equipment ... enhance technician productivity by

281

Test, M

easure

ment a

nd

Facilitie

s L

ocatin

g —

Dia

gnostic

Testin

g E

quip

ment

PHYSICAL SPECIFICATIONS3M™ DYNATEL™ SUBSCRIBER LOOP TESTER 946DSP

SIZE WEIGHT SHIPPING DISPLAY(H X W X D) IN. (CM) (INCLUDING BATTERIES) WEIGHT SIZE

946DSP (7.5"H x 4"W x 1.5"D ) 1 lb. with battery and soft case 1.5 lbs (0.7 kg) 2.25" x 1.25" 19 cm x 10.2 cm x 3.8 cm (0.5 kg) (5.7 cm x 3.2 cm)

ENVIRONMENTAL SPECIFICATIONSSUBSCRIBER LOOP TESTER 946DSP

Operating temperature 0° to 140°F (-17° to 60°C)

Storage temperature -40° to 140°F (-40° to 60°C)

Humidity 0 to 95%

Vibration Random 3-axis vibration at 12.5 Grms for 20 minutes

Rain proof/splash proof Meets UL50, Rain test

EMI/EMC Meets FCC part 15, Class A: Digital Devices for the US, and EN55022 (radiated emissions), EN55024-2 (electrostatic discharge), EN55024-3 (radiated immunity), EN55024-4 (transient immunity) and IEC1010 (product safety) for Europe.

GENERAL SPECIFICATIONSSUBSCRIBER LOOP TESTER 946DSP

Batteries 4 - disposable alkaline (AA or LR6) but will accept user providedNi-Cad or NiMH batteries with user provided external charger

Battery life Alkaline: up to 25 hours continuous, dependent on temperature and use of backlight.

Dialing DTMF and pulse dialing - 10 number storage 12 hours typical use (50% on/off measures voltage)

Display Graphical LCD with universal icons

Test leads Removable red, black and green leads; 5 ft. (1.5 m)

Over voltage protection 450 VDC, 250 VAC. between any leads to protect the internal circuit

Keypad Field-rugged, waterproof membrane keypad

Function keys V (voltage), mA (loop current/ground resistance), ohms(resistance/soak test), OPENS, TONE, DB, AUTO Cal.Two non-testing function keys are ‘ * ’ and ‘#’

Note: Routine calibration is not recommended or required** Percent of reading** Psophometric filter is available as a special order

Page 14: Dynatel Diagnostic Testing Equipmentmultimedia.3m.com/mws/media/357585O/3m-test-and-measurement... · Dynatel™ Diagnostic Testing Equipment ... enhance technician productivity by

282 www.3MTelecommunications.com 800-426-8688

3M™ DYNATEL 900 SERIES SUBSCRIBER LOOP TEST PRODUCT ACCESSORIESPRODUCT NUMBER/PACKAGING INFO

1146PKG. (LBS.): 1 EACH (0.10)MIN. ORDER: 1 EACHUPC: 051138-57744

1149PKG. (LBS.): 1 EACH (0.10)MIN. ORDER: 1 EACHUPC: 051138-57685

1145PKG. (LBS.): 1 EACH (0.10)MIN. ORDER: 1 EACHUPC: 051138-58628

1148PKG. (LBS.): 1 EACH (0.44)MIN. ORDER: 1 EACHUPC: 051138-57686

1151PKG. (LBS.): 1 EACH (0.20)MIN. ORDER: 1 EACHUPC: 051138-87178

1181PKG. (LBS.): 1 EACH (3.00)MIN. ORDER: 1 EACHUPC: 051115-15090

1147PKG. (LBS.): 1 EACH (0.10)MIN. ORDER: 1 EACHUPC: 051138-58529

900-IRPKG. (LBS.): 1 EACH (0.10)MIN. ORDER: 1 EACHUPC: 051138-58764

DESCRIPTION

Cigarette Lighter AdapterFor 965DSP tester.

Alkaline Battery HolderFor 900 series tester.

Adapter 110/220 VACFor 965DSP tester.

Nickel Metal Hydride Battery PackFor 965DSP tester.

Soft Carrying CaseFor 965DSP and 965DSP/SA testers.

Soft Carrying CaseFor 965DSP/ADSL tester.

Ground Strap, Shorting, AlligatorFor 965DSP tester.

IR Adapter CableFor 900 series tester.

Page 15: Dynatel Diagnostic Testing Equipmentmultimedia.3m.com/mws/media/357585O/3m-test-and-measurement... · Dynatel™ Diagnostic Testing Equipment ... enhance technician productivity by

283

Test, M

easure

ment a

nd

Facilitie

s L

ocatin

g —

Dia

gnostic

Testin

g E

quip

ment

3M™ DYNATEL 900 SERIES SUBSCRIBER LOOP TEST PRODUCT ACCESSORIESPRODUCT NUMBER/PACKAGING INFO

1142PKG. (LBS.): 1 EACH (0.10)MIN. ORDER: 1 EACHUPC: 051138-57649

1143PKG. (LBS.): 1 EACH (0.10)MIN. ORDER: 1 EACHUPC: 051138-57650

1144PKG. (LBS.): 1 EACH (0.10)MIN. ORDER: 1 EACHUPC: 051138-57648

1342PKG. (LBS.): 1 EACH (2.00)MIN. ORDER: 1 EACHUPC: 051138-87639

1343PKG. (LBS.): 1 EACH (2.00)MIN. ORDER: 1 EACHUPC: 051138-87640

1344PKG.: 1 EACHMIN. ORDER: 1 EACHUPC: 051138-89794

1110PKG.: 1 EACHMIN. ORDER: 1 EACHUPC: 051115-13550

DESCRIPTION

Lead Test, Blue/Yellow Alligator Clip and Bed-of-NailsFor 965DSP tester.

Green Lead Test Alligator Clip and Bed-of-NailsFor 945DSP and 965DSP testers.

Black/Red Lead Test Alligator Clip and Bed-of-NailsFor 945DSP and 965DSP testers.

Far End Device IIUse with 965DSP tester with alligator clips.

Far End Device IIUse with 965DSP tester with bed-of-nails and alligator clips.

Far End Device IIWith alligator clip and long/single needle.

Test Lead with RJ45/Alligator Clip, 7 LeadsFor 1342 far end device II.

Page 16: Dynatel Diagnostic Testing Equipmentmultimedia.3m.com/mws/media/357585O/3m-test-and-measurement... · Dynatel™ Diagnostic Testing Equipment ... enhance technician productivity by

284 www.3MTelecommunications.com 800-426-8688

3M™ DYNATEL™ QUALIFICATION TEST SETS949 AND 950ADSL

The 949 and 950ADSL qualification test sets can provide a low-costsolution for POTS testing and verification of ADSL modem connectivity at customer locations.

Rugged Reliable Design

The Dynatel test sets are housed in a light-weight, hand-held casedesigned for ease-of-handling and portability. Each unit weighs less than 2.5 pounds with the rechargeable battery pack included. The Dynatel brand and its distinctive Dynatel yellow color are your assurances of rugged reliability.

ADDITIONAL POTS MEASUREMENT SPECIFICATIONS

QUALIFICATION TEST SET 950ADSL

FUNCTION RANGE RESOLUTION ACCURACY* TEST LEADS

Loop current (DC) 0 to ±110 mA 1 mA ±2mA R-T (Impedance = 430 ø)

Loop resistance 0 ohm to 999 ohms 1 ohm ± 5 ohm ± 3% R-T, R-G, T-G

Loop loss -50 to +10 dBm 1 dB ±1 dB R-T (Impedance = 600 ø)200 to 5000 Hz

Frequency during loss,single frequency only 200 to 5,000 Hz 1 Hz ±3 Hz R-T

Noise metallic withC-message weighting** 0 to 60 dBrnc 1 dB ±2 dB R-T (Impedance = 600 ø)

Noise to ground with C-message weighting** 40 to 100 dBrnc 1 dB ±2 dB R and T-G (Impedance = 100KW)

Opens 0 to 9,999 ft. 1 ft. ± 20 ft. ±5% Ring, tip, mutual10,000 to 99,999 ft 100ft +/- 5%

(0 to 9,999 m) (1 m) (± 6m, ±5%)(10,000 to 30,000m) (100m) (+/- 5%)

Longitudinal balance 0 – 65 dB 1 dB ±2 dB TR-G.

Ground resistance 0 to 50 ø 1 ø ± 3 ø

Load coils Count 0,1,2,3,4 or >4 coils +/- 1 coilNote: First load must be >3000’ from the unit and 3000’ of cable must extend beyond the last load coil for an accurate count

*Percent of reading

**C-message specification has additional frequency dependent tolerance. Refer to “Subscriber Loop Transmission Test Set Specification”, Bell System PUB 55020, January 1982.

GENERAL SPECIFICATIONS

QUALIFICATION TEST SET 950ADSL

POTS test storage 10 Sets of results, each identified with a 10 digit numeric identifier.Stored results can be viewed in the test set.

POTS auto-test Auto-test will run the following tests: V (T, R, G), mA, ground resistance, ohms (T, R, G), opens (T, R, G),load coil count, noise, PI, LB and loss (up to 10 voiceband frequencies).

Page 17: Dynatel Diagnostic Testing Equipmentmultimedia.3m.com/mws/media/357585O/3m-test-and-measurement... · Dynatel™ Diagnostic Testing Equipment ... enhance technician productivity by

285

Test, M

easure

ment a

nd

Facilitie

s L

ocatin

g —

Dia

gnostic

Testin

g E

quip

ment

3M™ DYNATEL™ QUALIFICATION TEST SETS949 AND 950ADSL

POTS and ADSL Tests

Metallic tests conducted by the 949 and 950ADSL qualification test sets include COand foreign voltage, insulation resistance, loop resistance, and longitudinal balance.

As a tone source, the testers are capable of generating 200Hz and 2MHz sinewave tones. Additional qualification tests include ADSL modem linkup and essential

performance measurements including connect rates, error statistics, and bin-graph. Test sets also have the capability to ping to an ISP. ADSL test results can be

saved and viewed in the unit or uploaded to a computer as needed. The 950 testset can perform a POTS autotest which can be saved and uploaded to a computer.

PRODUCT FEATURES

QUALIFICATION TEST SET

TESTS PERFORMED 949ADSL TEST SET 950ADSL TEST SET

Volts – AC and DC • •

Loop current •

Resistance test • •

Soak test •

Ground resistance •

Opens •

Loss and noise •

Longitudinal balance • •

Dial key •

Load coils •

POTS autotest •

Precision tones to 2MHz • •

ADSL connectivity • •

PING testing • •

FEATURES 949ADSL TEST SET 950ADSL TEST SET

Backlit LCD • •

RJ45 attachment for test leads • •

Rechargeable NiMH battery • •

Serial upload to PC • •

Storage for 200 ADSL results • •

Storage for 10 POTS results •

Page 18: Dynatel Diagnostic Testing Equipmentmultimedia.3m.com/mws/media/357585O/3m-test-and-measurement... · Dynatel™ Diagnostic Testing Equipment ... enhance technician productivity by

286 www.3MTelecommunications.com 800-426-8688

GENERAL SPECIFICATIONS

QUALIFICATION TEST SET 949ADSL

Size 60 mm high x 100 mm wide x 200 mm long

Weight Less than 2.5 lb. with battery

Battery NiMH 2.1 Ahr – shrink wrap pack, user replaceable through access door on back of unit

Battery life 8 hours standby (Backlite Off) + 20 full ADSL qualification testsAC/DC adapter connects to the unit through the RJ45 test lead jackThe unit cannot make measurements while powered by the AC/DC adapterAuto shutoff after 5 minutes with no activity, except during charging

Display 64 x 128 pixel, 57 mm x 31 mm viewing area with LED backlight

Test leads Red, black and green leads. 1.5 meter long. Connected to unit via RJ45 jack

Breakdown voltage 360 VDC, 250 VAC. (the unit will be damaged if exposed to voltages exceeding these limits)

Operating temperature -10°C to 60°C except for ADSL and battery charger functions0°C to 60°C ADSL functions (temperatures > 50°C performance could degrade)0°C to 50°C battery charger operation

Humidity 0 to 80% non-condensing

Rain proof/splash proof Conforms to IP42

Shock Will survive 3 foot drop to concrete

Regulatory CE / FCC

ADSL test storage 200 sets of results identified with an alphanumeric labelStored results can be viewed in the test set.

Languages English

RS232 port An RJ45 to DB9 adapter cable is provided to permit connecting the 949 and 950ADSL to a PCThe serial connection supports the following:• Upload of test results to the PC• Field software updates

ADSL MEASUREMENT SPECIFICATIONS

3M™ DYNATEL™ QUALIFICATION TEST SETS 949 AND 950ADSL

ADSL standards ANSI T1.413ITU-T G.992.2 (G.LITE)ITU-T G.992.1 (G.DMT) - Annex A

IP encapsulation LLC SNAP or VC MUX

IP transport protocols DHCPoE – IP on Ethernet over ATMDHCPoA - IP over ATMStaticIPoE – IP on Ethernet over ATMStaticIPoA - IP over ATMPPPoE - PPP over Ethernet over ATMPPPoA - PPP over ATM

PPP authentication CHAP or PAP

Line impedance 100 ohms, nominally

FUNCTION MEASUREMENT ACCURACY

ADSL status Fast rate up/down +/- 1 kbpsInterleaved rate up/down +/- 1 kbpsMax rate up/down +/- 1 kbpsMargin up/down +/- 1 dBAttenuation up/down +/- 1 dBCapacity up/down +/- 1 %

ADSL information FEC errors up/down +/- 1CRC errors up/down +/- 1HEC errors up/down +/- 1Bin graph

ADSL alarms Loss of Signal (LOS)Loss of Frame (LOF)Loss of Power (LOP)Loss of Margin (LOM)

Ping Connection time +/- 10mS

Page 19: Dynatel Diagnostic Testing Equipmentmultimedia.3m.com/mws/media/357585O/3m-test-and-measurement... · Dynatel™ Diagnostic Testing Equipment ... enhance technician productivity by

287

Test, M

easure

ment a

nd

Facilitie

s L

ocatin

g —

Dia

gnostic

Testin

g E

quip

ment

POTS MEASUREMENT SPECIFICATIONS3M™ DYNATEL™ QUALIFICATION TEST SETS 949 AND 950ADSL

FUNCTION RANGE RESOLUTION ACCURACY* TEST LEADS

AC voltage 0 to 250 VAC ± 1 V ± 2% R-T, R-G, T-G(input resistance = 1M Ohm ± 5%)

DC voltage 0 to 250 VDC ± 1 V ± 2% R-T, R-G, T-G(input resistance = 1M Ohm ± 5%)

Resistance 0 ohm to 999 ohms 1 ohm ± 5 ohm ± 3% R-T, R-G, T-G1k ohm to 9.9k ohms 10 ohms ± 3%

10k ohms to 99.9k ohms 100 ohm ± 3%10k ohms to 999k ohms 1k ohm ± 3%

1M ohm to 9.9M ohms 100k ohms ± 3%10M ohms to 30M ohms 1M ohm ± 10%

Active pair: 0 to -60 VDC R-T voltage, 600 ohm to 7k ohmsInactive pair: 0 to -90 VDC R-T voltage, 600 ohms to 1 Megohm

Longitudinal balance 0 – 65 dB 1 dB ±2 dB TR-G

Precision tone Frequency 404Hz, 1004Hz, 2804Hz (preset) Amplitude 0 ± 0.5 dBm R-TSource Impedance 600 ohms +/- 5%

Frequency 8000 – 2MHz (user settable) +/- 10% Amplitude 0 ± 0.5 dBm R-TSource Impedance 100 ohms +/- 5%

577 Hz intermittent trace tone Amplitude 5V P-P

*Percent of reading

ORDERING INFORMATIONPRODUCT NUMBER DESCRIPTION PKG. (LBS.) MIN. ORDER UPC 051115-

CE100699624 949ADSL qualification test set 1 each (3.60) 1 each 18042

CE100699632 950ADSL qualification test set w/enhanced testing capability 1 each (3.60) 1 each 18073

CE100700687 AC/DC adapter, 120VAC input 1 each 1 each 19407

CE100700695 Test leads 949/950, red/black/green 1 each 1 each 19408

CE100700711 Serial cable 1 each 1 each 19409

CE100700729 Telephone patch cord 1 each 1 each 19410

CE100700737 Soft carry case 1 each 1 each 19411

CE100700745 Rechargeable NiMH battery pack 1 each 1 each 19412

CE100700752 AC/DC adapter, 220VAC – – –

Page 20: Dynatel Diagnostic Testing Equipmentmultimedia.3m.com/mws/media/357585O/3m-test-and-measurement... · Dynatel™ Diagnostic Testing Equipment ... enhance technician productivity by

288 www.3MTelecommunications.com 800-426-8688

3M™ Dynatel™ Advanced Modular System 965AMS

The new 965AMS advanced modular system contains every feature of our previous

965 model plus a larger, brighter display that features 3M™ Vikuiti™ Display Enhancement

technology, a user-friendly icon-based interface and rugged field-swappable module.

The external modules can be shared between technicians and allows transmission testing

of a variety of OSP technologies. The platform is available with an optional ADSL2+ modem

module. Development for future modules may include such features as: VDSL2, FTTx fiber

test, VoIP, DS1, DS3 and new technologies yet to come.

Page 21: Dynatel Diagnostic Testing Equipmentmultimedia.3m.com/mws/media/357585O/3m-test-and-measurement... · Dynatel™ Diagnostic Testing Equipment ... enhance technician productivity by

289

Test, M

easure

ment a

nd

Facilitie

s L

ocatin

g —

Dia

gnostic

Testin

g E

quip

ment

The complete testing platform for all outside plant telecommunications.

This microcomputer-controlled flexible test set family provides

full-featured testing for the triple play—voice, video and data circuits.

Because it’s a Dynatel 965 series tester, the AMS model is easy to use,

requiring minimal training for testing professionals. And because

it emphasizes fault diagnosis and fault location, customer can use

the tester to assist in quick problem solving.

Autotest

The knowledge-based smart autotest function allows

automatic test of active and inactive lines with pass/fail limits. Autotest

capabilities also include expert system analysis of test results with

advice on how to repair or how to locate faults. 3M™ Dynatel Far End

Device FED II and customizable selections of tests are supported

by the autotest feature of the 965AMS platform.

External Modules

965AMS modules support special circuits technicians who work on a

variety of circuit standards during a typical day. Because the modules

are field swappable, the technicians can share them. The ADSL2+

module is currently available. The following is a list of future modem

protocols: VDSL2, FTTx fiber test and VoIP.

Rugged, Weather-Resistant Design

The hand-held 965AMS product is housed in a lightweight,

ergonomically-designed case. The weather-resistant unit weighs

only 5 lbs (2.2kg) and operates on a desktop, on the ground, in aerial

environments and underground locations.

3M™ DYNATEL™ ADVANCED MODULAR SYSTEM 965AMS

Page 22: Dynatel Diagnostic Testing Equipmentmultimedia.3m.com/mws/media/357585O/3m-test-and-measurement... · Dynatel™ Diagnostic Testing Equipment ... enhance technician productivity by

290

PHYSICAL SPECIFICATIONSSIZE (H X W X D) IN. (CM) WEIGHT (INCLUDING BATTERIES)

965AMS (includes ADSL2+ module) 11.5 x 5.75 x 3.25 (29 x 14.5 x 8.3) 5 LB (2.2 KG)

ACCESSORIESPRODUCT NAME DESCRIPTION

Test Leads Five 5-ft (1.5 m) test leads with 2 mm gold-plated banana plugs one end and chrome-plated alligator clips on other end (black/red, blue/yellow, green)Lead styles include bed of nails, no nails, spike and Canadian test leads

European Test Leads Five 5-ft (1.5 m) test leads with 2 mm gold-plated banana plugs one end and 4-mm gold-plated banana plugs on other end (black/red, blue/yellow, green)

RFL Strap 1.5 ft (0.5 m) with alligator clips on ends

AC/DC Adapter 100-250 VAC (50/60 Hz) input, 12 VDC (1 A) output Power cord with IEC socket, US cord included

ENVIRONMENTAL SPECIFICATIONSOperating temperature 0° to 140°F (-18 to 60°C)

Storage temperature -40° to 165°F (-40 to 75°C)

Moisture: rain, water and humidity proof Meets or exceeds 1P65, 1P67

FEATURES BENEFITS3M™ DYNATEL™ ADVANCED MODULAR SYSTEM 965AMS

Communications Capability to work with a PC or handheld computer supporting software upload and data downloads

Flexible architecture Supports various data modem protocols such as ADSL2+

Graphical user interface User-friendly, icon-based display of test results

Help function An internal help and tutorial provides information as needed during operation

Backlight High resolution/high contrast black and white LCD display

Vehicle power adapter Plugs into standard vehicle accessory outlet

Windows/CE operating system Provides open architecture software environment

Keyboard Allows rapid access to twelve different “blue key” functions, reducing menu levels. Also has cursors, and supports alpha-numeric entry1

Yellow and green LED lights Signal battery state and communication status

Software TDR and auto-test knowledge based systems aids technicians during test interpretation

Bright big screen Highly visible even in bright sunlight due to proprietary 3M™ Vikuiti™ brightness enhancement technology, 80% larger than 965DSP

Modular design All you need is a new module to increase test capability (no need to replace test set)

Dynatel yellow Rugged, dependable

Page 23: Dynatel Diagnostic Testing Equipmentmultimedia.3m.com/mws/media/357585O/3m-test-and-measurement... · Dynatel™ Diagnostic Testing Equipment ... enhance technician productivity by

291

Test, M

easure

ment a

nd

Facilitie

s L

ocatin

g —

Dia

gnostic

Testin

g E

quip

ment

ELECTRICAL SPECIFICATIONS3M™ DYNATEL™ ADVANCED MODULAR SYSTEM 965AMS

FUNCTION RANGE RESOLUTION ACCURACY ±

Voltage (DC) 0 to 99.9 V 0.1 V 1% ± 0.5 V100 to 300 V 1 V 3%

Voltage (AC) 0 to 99.9 V 0.1 V 1% ± 0.5 V20 to 4 KHz 100 to 250 V 1 V 3%Meter resistance 100 K or 1 M

Current 0 to 59.9 mA 0.1 mA 1% ± 0.3 mA60 to 110 mA 0.1 mA 2%

Shunt resistance 430 Ω

Resistance 0 to 9999 Ω 1 Ω 1% ± 5 ΩWith CO voltage 0 to 9999 Ω 1 Ω 1% ± 50 Ω

10 k to 99.9 kΩ 0.1 kΩ 1%100 k to 999 kΩ 1 kΩ 3%1 M to 9.9 MΩ 10 kΩ 3%10 M to 99 MΩ 0.1 MΩ 5%

100 M to 990 MΩ 1 MΩ 10%

Opens (no noise) 0 to 3,000 ft (0 to 1,000 m) 1 ft (1 m) 1% ± 3 ft (1 m)3,000 to 10,000 ft (1 km to 3 km) 1 ft (1 m) 3%

10,000 to 50,000 ft (3 km to 15 km) 10 ft (10 m) 5%50,000 to 100,000 ft (15 km to 30 km) 100 ft (100 m) 10%

RFLFault range 0 to 20 MΩ — —Resistance to 0 to 99.99 Ω RTS 0.01 Ω 0.1% of RTS ± 0.01 ΩFault (no noise) 100 to 999.9 Ω RTS 0.1 Ω 0.2% of RTS ± 0.01 Ω

1 k to 3 kΩ RTS 1.0 Ω 1.0% of RTS ± 0.01 Ω

Wet section test Loop resistance 0 to 7 kΩ — —Resistive balance 0 to 3.5 kΩ — 5%

Loop resistance 0 to 99.9 Ω 0.01 Ω 0.1% ± 0.01 Ω100 to 999.9 Ω 0.1 Ω 0.2% ± 0.01 Ω1000 to 7000 Ω 1 Ω 1.0% ± 0.01 Ω

Resistance difference 0 to 99.99 Ω 0.01 Ω 1% of loop resistance ± 0.01 Ω

Tone outputID tone 200 to 1000 Hz, fixed level 8 volt peak to peak +1 Hz Precision tone- 600 Ω Zout 200 to 9999 Hz, -20 to +1 dBm 1 Hz, 0.1 dB 1% Hz, 0.2 dB

10 k to 19.99 kHz, -20 to +1 dBm 1 Hz, 0.1 dB 2% Hz, 1 dB

Ringers 0.0 to 4.0 ringer 0.1 ringer0 to 2000 nF 10 nF

Load coil count 0 to 5 1 ±1 load coil

Ground resistance 5 to 500 Ω 1 Ω 1% ± 1 Ω

Ohms/distance calculator 0-9999 Ω 0.01 —0-99999 ft (0-30 km) 1 ft (0.1 m) —

Note: 1All resistance to fault measurement accuracies have an added factor of (2x10-8) Rf ohms (Rf=fault resistance in ohms)

Page 24: Dynatel Diagnostic Testing Equipmentmultimedia.3m.com/mws/media/357585O/3m-test-and-measurement... · Dynatel™ Diagnostic Testing Equipment ... enhance technician productivity by

292 www.3MTelecommunications.com 800-426-8688

ELECTRICAL SPECIFICATIONS (CON’T FROM PREVIOUS PAGE)3M™ DYNATEL™ ADVANCED MODULAR SYSTEM 965AMS

FUNCTIONS RANGE RESOLUTION ACCURACY

TDR *Ranges 100 ft, 200 ft, 500 ft, 1,000 ft, 1 ft (1 m) 0.3% range

2,000 ft, 5,000 ft, 10,000 ft, 20,000 ft,30,000 ft (30 m, 60 m, 150 m, 300 m,

600 m, 1.5 km, 3km, 6 km, 10 km) 5 nS, 34 nS, 135 nS, Fixed values1600 nS, 600 nS

Velocity input 0.50 to 0.99 (150 to 299 m/µs) — —

Modes Single trace, dual trace, differential, — —memory, crosstalk, Peak, memory diff.

Loss (and frequency) -40 to +10 dBm, 200 to 3000 Hz, 0.1 dB, 1 Hz, ± 0.5 dB, 2 HzWith 600 Ω Zin -40 to +10 dBm, 3000 to 9995 Hz, 0.1 dB, 10 Hz ± 0.5 dB, 10 Hz

-40 to +10 dBm, 10 k to 19.9 kHz 1 dB, 10 Hz ± 1 dB, 20 Hz

Noise metallic 600 Ω Zin 0 to 50 dBrnc (-90 to –40 dBm0p) 1 dB ± 2 dBC and psophometric

Noise to ground 600 Ω Zin 40 to 100 dBrnc (-50 to 10 dBm0p) 1 dB ± 2 dB

Longitudinal balance 0 to 85 dB 1 dB ± 2 dB

Dial mode DTMF, Pulse Standard Standard

Caller ID (U.S. and Canada only) Date, time, number, name —Carrier level -4 to –32 dBm 1 dBm ± 2 dBm

Short range wideband specifications (without SA option)Wideband loss -50 to +2 dBm, 20 kHz to 1.2 MHz .1 dB, 100 Hz ± 2 dB, 1% Hz100, 135 Ω ZinWideband tone output–100,135 Ω Zout 0 dBm, 20 k to 2.2 MHz 1 kHz ± 1 dB at 2.2 MHz

SA wideband specificationsWideband loss -85 to +5 dBm, 20 kHz to 2.2 MHz .1 dB, 100 Hz ± 1 dB, 1%Hz100, 135 Ω Zin

Wideband noise metallic E filter 10-90 dBm 1 dB ± 2 dB100, 135 Ω Zin F filter 20-90 dBm 1 dB ± 2 dBE, F, G, and G2 filters G filter 30-90 dBm 1 dB ± 2 dB

Wideband spectral analysis 10 kHz to 2.2 MHz 0.5% of span 1%100, 135 Ω Zin – 90 dBm to +10 dBm 1dBDynamic RangeWideband tone output–100,135 Ω Zout 0 dBm, 20 k to 2.2 MHz 1 kHz ± 1 dB at 2.2 MHz

± 0.1% frequency ± 0.5 kHz

Impulse noise countingE, F, G, and G2 filters

Counting interval 1-60 minutes 1 minute ±5%

Threshold Lower limits: 30 dBrnC and E 1 dB ±1 dB (typical)40 dBrnF50 dBrnG

100 dBrn upper limitAll 30 dB higher for N to Ground

Count capacity 9999 1 —

Page 25: Dynatel Diagnostic Testing Equipmentmultimedia.3m.com/mws/media/357585O/3m-test-and-measurement... · Dynatel™ Diagnostic Testing Equipment ... enhance technician productivity by

293

Test, M

easure

ment a

nd

Facilitie

s L

ocatin

g —

Dia

gnostic

Testin

g E

quip

ment

GENERAL SPECIFICATIONSDrop test Survives 3 ft (1 m) drop onto concrete, using ASTM D4169 assurance

level I method 5276

Vibration Meets Mil 810F method 514.5

Water, dust and chemical proof Meets IP65 per IEC 529(1989) for rain and dustImmersion test IP67 0.15 m deep

Emissions Standards meet FCC part 15, class A: Digital Devices for the US, and EN55022 (radiated emissions)

Built to ISO9001/2000 certification for manufacturing facilities and TL9000 compliant

Built to ANSI/IPC A610-C manufacturing standards

Language English, Spanish, and French Canadian*

Units Feet or meters, Fahrenheit or Celsius, dBrnC or dBm0p, m/uS or Vf

Battery Rechargeable battery pack or alkaline, 9 hours typical use (50% on/off measures voltage)

Display 4.1" x 3.1"(104 x 79 mm), 320 x 240 pixel resolution, high visibility in bright sunlight due to 3M™ Vikuiti™ film technology

Stored results (All results) 100 results total of all types maximum

Note: Routine lab calibration is not recommended or required*Available late 2005

ELECTRICAL SPECIFICATIONS3M™ DYNATEL™ ADVANCED MODULAR SYSTEM 965AMS

FUNCTIONS RANGE

Filters: C and Psophometric 300 Hz – 3400 HzE filter 1 kHz – 50 kHzF filter 4.9 kHz – 245 kHzG filter 20 kHz – 1.1 MHz – 3 dB pointsG2 filter 20 kHz – 2.2 MHz

FEATURESMODEL NAME 965AMS 965AMS 965AMS 965AMS 965AMS BASIC 965AMS

BASIC TDR TDR+SA BASIC+ADSL2+ TDR+ADSL2+ SA+ADSL2+

FEATURES

Basic VOM and POTS • • • • • •

TDR • • • •

Short range wideband loss/tone • • • •

Wideband spectrum analysis + loss/tone • •

ADSL2+ modem • • •

Page 26: Dynatel Diagnostic Testing Equipmentmultimedia.3m.com/mws/media/357585O/3m-test-and-measurement... · Dynatel™ Diagnostic Testing Equipment ... enhance technician productivity by

294 www.3MTelecommunications.com 800-426-8688

FEATURES

3M™ DYNATEL™ ADVANCED MODULAR SYSTEM 965AMS

Interconnectivity All modules include

RS232 Communicates with a PC using a supplied cable

USB active synch client 1.1 Includes required USB cables

Battery charger port

Test lead connectors

Basic VOM All versions have these features

Voltage Detects and measures the presence of central office (exchange) or foreign DC or AC voltages, including ringer voltages

Current Measures DC loop current with a 430-ohm shunt

Resistance Measures conductor and insulation resistance up to 1GigaOhms

Soak test High voltage extended period resistance measurement that will expose corrosion-induced faults

Opens Locates opens at distances up to 100,000 ft. (30 km)

Resistive fault location Displays distance to fault

Special resistance Measures the loop resistance and the resistance differencebetween two conductors on a pair

Wet section test Allows RFL measurement when both wires in a pair are faulted and there is no separate good pair available

Ringers Measures and displays capacitance associated with one or more ringers and the equivalent count

Ground resistance Measures the resistance of the ground path

ID tone High power interrupted signal for tracing and identification

Kick test Rapid, fast combination of resistance, voltage and opens for quickly evaluating cable pairs

Voice band tests Noise, loss, tone, longitudinal balance, load coil counting and FED compatibility

Load coil count Indicates the presence of load coils in a loop circuit and distance to the first load coil

Loss Measures voiceband loss

Noise Measures noise metallic and noise to ground in dBrnC or dBm0p

Longitudinal balance Provides active measurement of line balance

Level trace Measures and displays the impedance of the un-terminated line as a function of frequency

Tone Provides test tones for conductor identification and transmission testing. 10 default tones, user selectable. Voiceband to 20 kHz, ID tones to 1000 Hz

Autotest Supports 3M Dynatel Far End Device FED II

Dialing Offhook, dialing capability, monitoring capability

Microphone and speaker capability Speaker has 1-watt power output for noisy environments

Caller ID functionality Displays number, name, date, and time just like the customers callbox

Wideband shortrange testing Wideband loss with limited range, wideband tone. This feature set is enabled in the basic and TDR units. Wideband loss measurements for short range orlow frequency

Test impendance 135 ohms only

Tone 20kHz to 1.2MHz at OdBm

Page 27: Dynatel Diagnostic Testing Equipmentmultimedia.3m.com/mws/media/357585O/3m-test-and-measurement... · Dynatel™ Diagnostic Testing Equipment ... enhance technician productivity by

295

Test, M

easure

ment a

nd

Facilitie

s L

ocatin

g —

Dia

gnostic

Testin

g E

quip

ment

OPTIONAL FEATURES3M™ DYNATEL™ ADVANCED MODULAR SYSTEM 965AMS

TDR Full-featured TDR with user-selectable pulse widths, length, gain zoom, filter and Vp. The TDR feature is enabled in the TDR and SA models

Single trace Provides graphical representation of events on a pair. Including expert system analysis of trace results

Dual trace Allows active comparison of two traces

Differential Displays difference between two circuits

Crosstalk Displays the crosstalk from one pair to another

Memory Allows comparison of an active trace with a trace stored in memory

Memory diff Difference between memory and live trace

Peak Displays a history of maximum and minimum values with the live trace

WideBand tests Wideband loss, wideband noise, wideband tone, spectrum analyzer this feature set is enabled in the SA models

WideBand Continuous sine wave insertion loss and noise measurements

Test impedances 100 and 135

Wideband loss Loss measurements to 2.2 MHz for pre-qualifying xDSL

Tone 20 kHz to 2.2 MHz at 0dBm

E, F, G, G2 filter Weighted noise and impulse noise counting

ORDERING INFORMATIONPRODUCT NUMBER STOCK NUMBER

965AMS-TDR/SA/ADSL2+/AC/DC/BON 80-6113-1614-4

965AMS-TDR/SA/ADSL2+/AC/DC/NN 80-6113-1660-7

KIT COMPONENTS965AMS BASIC

965AMS Basic 965AMS base unit storage bag, blue, yellow, green, red and black test leads. Conductor strap, NiMH battery pack (packed in unit), alkaline battery holder, wire gauge, self test circuit board and chain bead, 110/220V AC adapter, certificate of calibration, vehicle power adapter, instruction manual, warranty card, quick reference cards, USB cable and ethernet cable (with ASDL2 options).

For ordering information, please contact your local 3M representative.

Page 28: Dynatel Diagnostic Testing Equipmentmultimedia.3m.com/mws/media/357585O/3m-test-and-measurement... · Dynatel™ Diagnostic Testing Equipment ... enhance technician productivity by

296 www.3MTelecommunications.com 800-426-8688296