DRAWING INDEX A000 - A1 COVER FSP 1 TITLE SHEET FSP 2 ...€¦ · 10/17/2017  · a105 - a1 roof...

13
A1 KEY PLAN MOONEY STREET BA N K E R D R I V E B R I D GE P A R K A V E NU E MOONEY STREET LONGSHORE STREET LONGSHORE STREET MIXED USE BUILDING TYPE 09/26/2017 DRAWING INDEX A000 - A1 COVER A001 - A1 DRAWING INDEX FSP 1 TITLE SHEET FSP 2 EXISTING CONDITIONS FSP 3 OVERALL PLAN FSP 4 SITE PLAN FSP 5 GRADING & UTILITY PLAN LANDSCAPE PLAN A100 - A1 SITE PLAN A101 - A1 FIRST FLOOR PLAN A102 - A1 SECOND FLOOR PLAN A103 - A1 THIRD FLOOR PLAN A104 - A1 FOUTH FLOOR PLAN A105 - A1 ROOF PLAN A301 - A1 SOUTH ELEVATION A302 - A1 WEST ELEVATION A303 - A1 NORTH ELEVATION A304 - A1 EAST ELEVATION A305 - A1 BUILDING SECTION A306 - A1 3D IMAGE - NORTHWEST VIEW A307 - A1 3D IMAGE - SOUTHEAST VIEW A308 - A1 3D ELEVATIONS A501 - A1 WALL SECTION - SOUTH A502 - A1 WALL SECTION - WEST A503 - A1 WALL SECTION - NORTH A503 - A1 WALL SECTION - EAST STONE DETAILS ALUM. COMPOSITE METAL A001-A1 DRAWING INDEX

Transcript of DRAWING INDEX A000 - A1 COVER FSP 1 TITLE SHEET FSP 2 ...€¦ · 10/17/2017  · a105 - a1 roof...

Page 1: DRAWING INDEX A000 - A1 COVER FSP 1 TITLE SHEET FSP 2 ...€¦ · 10/17/2017  · a105 - a1 roof plan a301 - a1 south elevation a302 - a1 west elevation a303 - a1 north elevation

A1

KEY PLAN

MOONEY STREET

BA

NK

ER

DR

IVE

BR

IDG

E P

AR

K A

VE

NU

E

MOONEY STREET

LONGSHORE STREET

LONGSHORE STREET

MIXED USE BUILDING TYPE 09/26/2017

DRAWING INDEX

A000 - A1 COVERA001 - A1 DRAWING INDEXFSP 1 TITLE SHEETFSP 2 EXISTING CONDITIONSFSP 3 OVERALL PLANFSP 4 SITE PLANFSP 5 GRADING & UTILITY PLAN

LANDSCAPE PLANA100 - A1 SITE PLANA101 - A1 FIRST FLOOR PLANA102 - A1 SECOND FLOOR PLANA103 - A1 THIRD FLOOR PLANA104 - A1 FOUTH FLOOR PLANA105 - A1 ROOF PLANA301 - A1 SOUTH ELEVATIONA302 - A1 WEST ELEVATIONA303 - A1 NORTH ELEVATIONA304 - A1 EAST ELEVATIONA305 - A1 BUILDING SECTIONA306 - A1 3D IMAGE - NORTHWEST VIEWA307 - A1 3D IMAGE - SOUTHEAST VIEWA308 - A1 3D ELEVATIONSA501 - A1 WALL SECTION - SOUTHA502 - A1 WALL SECTION - WESTA503 - A1 WALL SECTION - NORTHA503 - A1 WALL SECTION - EAST

STONE DETAILSALUM. COMPOSITE METAL

A001-A1DRAWING INDEX

Page 2: DRAWING INDEX A000 - A1 COVER FSP 1 TITLE SHEET FSP 2 ...€¦ · 10/17/2017  · a105 - a1 roof plan a301 - a1 south elevation a302 - a1 west elevation a303 - a1 north elevation

FIRST FLOOR

100'-0"

SECOND FLOOR

116'-0"

THIRD FLOOR

130'-0"

FOURTH FLOOR

144'-0"

ROOF

158'-0"

WALL PANEL SYSTEM(COLOR B)

1

A305-A1

14'-0

"14

'-0"

14'-0

"16

'-0"

14'-0

"

3 5/8" CALCIUM SILICATEMANUFACTUREREDSTONE VENEER

IG-1: 1" EXTERIORINSULATED GLAZING

IG-2: 1" EXTERIORINSULATED SPANDRELGLAZING

STAINLESS STEELRAILING WITH GLASS

INFILL PANELS

3 5/8" CALCIUM SILICATEMANUFACTURERED

STONE VENEER

IG-2: 1" EXTERIORINSULATED SPANDREL

GLAZING

WALL PANEL SYSTEM(COLOR B)

IG-2: 1" EXTERIORINSULATED SPANDREL

GLAZING

UNITIZED GLAZEDALUMINUM CURTAIN

WALL SYSTEM

6'-11 1/8" 29'-10 15/16" 6'-1 3/8" 31'-10 1/4"7'-1 15/16"28'-4 1/2"

72'-0

"

A1 FIRST FLOOR

19' - 6"

A1

KEY PLAN

MOONEY STREET

BA

NK

ER

DR

IVE

BR

IDG

E P

AR

K A

VE

NU

E

MOONEY STREET

LONGSHORE STREET

LONGSHORE STREET

MIXED USE BUILDING TYPE 09/26/2017

ELEVATION 1/16" = 1'-0"

SCHEMATIC SOUTH10 16' 32' 40'

1/16" = 1'-0"

A301-A1SOUTH ELEVATION

STREET FACADETRANSPARENCY

1st StoryStory Area:Transparency:Required:Provided:

2,082 sf345 sf

70%17%

VERTICAL FACADE DIVISIONS

(45' OR LESS REQUIRED)

Calcium Silicate Masonry UnitsGlassAluminum Composite Metal

Misc. Elements

Material Primary/Secondary Area (SF) Percentage Required

PrimaryPrimaryPrimary

Trim

825 sf4,720 sf2,345 sf

10.5%59.8%29.7%

7,890 sf 100.0% 80%

000 sf

000 sf 0% <20%

0%

Overall Area of South Elevation:Area of Windows/Doors:Net Area of Elevation:

FACADE MATERIALS

8,060 sf 170 sf7,890 sf

Y

Y

2nd StoryStory Area:Transparency:Required:Provided:

1,698 sf698 sf

30%41%

3rd StoryStory Area:Transparency:Required:Provided:

4th StoryStory Area:Transparency:Required:Provided:

1,698 sf698 sf

30%41%

1,698 sf698 sf

30%41%

Page 3: DRAWING INDEX A000 - A1 COVER FSP 1 TITLE SHEET FSP 2 ...€¦ · 10/17/2017  · a105 - a1 roof plan a301 - a1 south elevation a302 - a1 west elevation a303 - a1 north elevation

FIRST FLOOR

100'-0"

SECOND FLOOR

116'-0"

THIRD FLOOR

130'-0"

T/O FOOTING

96'-0"

FOURTH FLOOR

144'-0"

ROOF

158'-0"

3 5/8" CALCIUM SILICATEMANUFACTURERED

STONE VENEER

WALL PANEL FASCIA/TRIM PANEL SYSTEM.

(COLOR C)

WALL PANEL SYSTEM(COLOR B)

IG-1: 1" EXTERIORINSULATED GLAZING

3 5/8" CALCIUM SILICATEMANUFACTUREREDSTONE VENEER

9'-10 1/4" 39'-8 3/16" 39'-11 3/8" 10'-0 5/8" 57'-6 7/8" 9'-3 15/16" 10'-8 1/8" 7'-7 1/4" 12'-2 5/8" 8'-7 5/16"

72'-0

"

16'-0

"

1

A502-A1

1

A504-A1

A1 FIRST FLOOR

19' - 6"

A1

KEY PLAN

MOONEY STREET

BA

NK

ER

DR

IVE

BR

IDG

E P

AR

K A

VE

NU

E

MOONEY STREET

LONGSHORE STREET

LONGSHORE STREET

MIXED USE BUILDING TYPE 09/26/2017

ELEVATION 1/16" = 1'-0"

SCHEMATIC WEST1A302-A1WEST ELEVATION

0 16' 32' 40'

1/16" = 1'-0"

NON-STREET FACADETRANSPARENCY

1st StoryStory Area:Transparency:Required:Provided:

3,425 sf97 sf15%3%

VERTICAL FACADE DIVISIONS

(45' OR LESS REQUIRED) - WAIVER REQUIRED FOR THIS ELEVATION

Calcium Silicate Masonry UnitsGlassAluminum Composite Metal

Misc. Elements

Material Primary/Secondary Area (SF) Percentage Required

PrimaryPrimaryPrimary

Trim

1,835 sf7,480 sf3,140 sf

14.7%60.1%25.2%

12,455 sf 100% 80%

000 sf

000 sf 0% <20%

0%

Overall Area of West Elevation:Area of Windows/Doors:Net Area of Elevation:

FACADE MATERIALS

12,545 sf 90 sf12,455 sf

Y

Y

2nd StoryStory Area:Transparency:Required:Provided:

2,214 sf983 sf

15%44%

3rd StoryStory Area:Transparency:Required:Provided:

4th StoryStory Area:Transparency:Required:Provided:

2,205 sf983 sf

15%45%

2,205 sf983 sf

15%45%

Page 4: DRAWING INDEX A000 - A1 COVER FSP 1 TITLE SHEET FSP 2 ...€¦ · 10/17/2017  · a105 - a1 roof plan a301 - a1 south elevation a302 - a1 west elevation a303 - a1 north elevation

FIRST FLOOR

100'-0"

SECOND FLOOR

116'-0"

THIRD FLOOR

130'-0"

T/O FOOTING

96'-0"

FOURTH FLOOR

144'-0"

ROOF

158'-0"

3 5/8" CALCIUM SILICATEMANUFACTUREREDSTONE VENEER

1

A305-A1

3 5/8" CALCIUM SILICATEMANUFACTUREREDSTONE VENEER

IG-1: 1" EXTERIORINSULATED GLAZING

IG-2: 1" EXTERIORINSULATED SPANDRELGLAZING

UNITIZED GLAZEDALUMINUM CURTAIN WALLSYSTEM

36'-1" 38'-7 1/2" 26'-1 1/2" 10'-0"

71'-9

"

1

A503-A1

A1 FIRST FLOOR

19' - 6"

A1

KEY PLAN

MOONEY STREET

BA

NK

ER

DR

IVE

BR

IDG

E P

AR

K A

VE

NU

E

MOONEY STREET

LONGSHORE STREET

LONGSHORE STREET

MIXED USE BUILDING TYPE 09/26/2017

ELEVATION 1/16" = 1'-0"

SCHEMATIC NORTH1A303-A1NORTH ELEVATION

0 16' 32' 40'

1/16" = 1'-0"

STREET FACADETRANSPARENCY

1st StoryStory Area:Transparency:Required:Provided:

1,762 sf320 sf

70%18%

VERTICAL FACADE DIVISIONS

(45' OR LESS REQUIRED)

Calcium Silicate Masonry UnitsGlassAluminum Composite Metal

Concrete & Misc. Elements

Material Primary/Secondary Area (SF) Percentage Required Met?

PrimaryPrimaryPrimary

Secondary

245 sf4,370 sf2,045 sf

3.7%65.0%30.4%

6,660 sf 99.1% 80%

60 sf

60 sf 0.9% <20%

0.9%

Overall Area of North Elevation:Area of Windows/Doors:Net Area of Elevation:

FACADE MATERIALS

6,730 sf 50 sf6,680 sf

Y

Y

2nd StoryStory Area:Transparency:Required:Provided:

1,418 sf585 sf

30%41%

3rd StoryStory Area:Transparency:Required:Provided:

4th StoryStory Area:Transparency:Required:Provided:

1,418 sf585 sf

30%41%

1,418 sf585 sf

30%41%

Page 5: DRAWING INDEX A000 - A1 COVER FSP 1 TITLE SHEET FSP 2 ...€¦ · 10/17/2017  · a105 - a1 roof plan a301 - a1 south elevation a302 - a1 west elevation a303 - a1 north elevation

FIRST FLOOR

100'-0"

SECOND FLOOR

116'-0"

THIRD FLOOR

130'-0"

T/O FOOTING

96'-0"

FOURTH FLOOR

144'-0"

ROOF

158'-0"

72'-0

"

10'-3 1/2" 56'-1 1/8" 70'-0"

1

A504-A1

A1 FIRST FLOOR

19' - 6"

A1

KEY PLAN

MOONEY STREET

BA

NK

ER

DR

IVE

BR

IDG

E P

AR

K A

VE

NU

E

MOONEY STREET

LONGSHORE STREET

LONGSHORE STREET

MIXED USE BUILDING TYPE 09/26/2017

ELEVATION 1/16" = 1'-0"

SCHEMATIC EAST1A304-A1EAST ELEVATION

0 16' 32' 40'

1/16" = 1'-0"

NON-STREET FACADETRANSPARENCY

1st StoryStory Area:Transparency:Required:Provided:

2,723 sf861 sf

15%32%

VERTICAL FACADE DIVISIONS

(45' OR LESS REQUIRED) - WAIVER REQUIRED FOR THIS ELEVATION

Calcium Silicate Masonry UnitsGlassAluminum Composite Metal

Misc. Elements

Material Primary/Secondary Area (SF) Percentage Required

PrimaryPrimaryPrimary

Trim

465 sf8,475 sf5,310 sf

3.3%52.1%44.6%

14,250 sf 100.0% 80%

0 sf

0 sf 0% <20%

0%

Overall Area of East Elevation:Area of Windows/Doors:Net Area of Elevation:

FACADE MATERIALS

Y

Y

2nd StoryStory Area:Transparency:Required:Provided:

2,882 sf1,220 sf

15%42%

3rd StoryStory Area:Transparency:Required:Provided:

4th StoryStory Area:Transparency:Required:Provided:

14,245 sf 0 sf14,245 sf

2,882 sf1,220 sf

15%42%

2,882 sf1,220 sf

15%42%

Page 6: DRAWING INDEX A000 - A1 COVER FSP 1 TITLE SHEET FSP 2 ...€¦ · 10/17/2017  · a105 - a1 roof plan a301 - a1 south elevation a302 - a1 west elevation a303 - a1 north elevation

A1

KEY PLAN

MOONEY STREET

BA

NK

ER

DR

IVE

BR

IDG

E P

AR

K A

VE

NU

E

MOONEY STREET

LONGSHORE STREET

LONGSHORE STREET

MIXED USE BUILDING TYPE 09/26/2017

A306-A1NORTHWEST VIEW

Page 7: DRAWING INDEX A000 - A1 COVER FSP 1 TITLE SHEET FSP 2 ...€¦ · 10/17/2017  · a105 - a1 roof plan a301 - a1 south elevation a302 - a1 west elevation a303 - a1 north elevation

A1

KEY PLAN

MOONEY STREET

BA

NK

ER

DR

IVE

BR

IDG

E P

AR

K A

VE

NU

E

MOONEY STREET

LONGSHORE STREET

LONGSHORE STREET

MIXED USE BUILDING TYPE 09/26/2017

A307-A1SOUTHEAST VIEW

Page 8: DRAWING INDEX A000 - A1 COVER FSP 1 TITLE SHEET FSP 2 ...€¦ · 10/17/2017  · a105 - a1 roof plan a301 - a1 south elevation a302 - a1 west elevation a303 - a1 north elevation

FIR

ST

FLO

OR

100'-0"

SE

CO

ND

FLO

OR

116'-0"

TH

IRD

FLO

OR

130'-0"

TH

IRD

FLO

OR

120'-0"

FO

UR

TH

FLO

OR

144'-0"

RO

OF

158'-0"

R.2

R.3

IG-1

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

GLA

ZIN

G

3 5/

8" C

ALC

IUM

SIL

ICA

TE

MA

NU

FA

CT

UR

ER

ED

ST

ON

E V

EN

EE

R

3 5/

8" C

ALC

IUM

SIL

ICA

TE

MA

NU

FA

CT

UR

ER

ED

ST

ON

E V

EN

EE

R

ST

AIN

LES

S S

TE

EL

RA

ILIN

G W

ITH

GLA

SS

INF

ILL

PA

NE

LS

ST

AIN

LES

S S

TE

EL

RA

ILIN

G W

ITH

GLA

SS

INF

ILL

PA

NE

LS

WA

LL P

AN

EL

SY

ST

EM

(CO

LOR

B)

CO

NC

RE

TE

TO

PP

ING

-S

LOP

E T

O D

RA

INS

IG-2

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

SP

AN

DR

EL

GLA

ZIN

G

PR

E-F

INIS

HE

D M

ET

AL

CO

PIN

G

? 2" P

ER

IME

TE

R A

ND

UN

DE

R S

LAB

INS

ULA

TIO

N

CO

NC

RE

TE

FO

UN

DA

TIO

NW

ALL

- S

EE

ST

RU

CT

UR

AL

DR

AW

ING

S

3'-3" 3'-0" 7'-6" 3'-6" 3'-0" 7'-6" 3'-6" 3'-0" 7'-6" 3'-6" 3'-0" 2'-6" 7'-0" 3'-6"

IG-2

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

SP

AN

DR

EL

GLA

ZIN

G

IG-1

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

GLA

ZIN

G

IG-1

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

GLA

ZIN

G

IG-2

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

SP

AN

DR

EL

GLA

ZIN

G

IG-2

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

SP

AN

DR

EL

GLA

ZIN

G

IG-2

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

SP

AN

DR

EL

GLA

ZIN

G

IG-1

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

GLA

ZIN

G

IG-1

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

GLA

ZIN

G

IG-2

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

SP

AN

DR

EL

GLA

ZIN

G

UN

ITIZ

ED

GLA

ZE

DA

LUM

INU

M C

UR

TA

IN W

ALL

SY

ST

EM

UN

ITIZ

ED

GLA

ZE

DA

LUM

INU

M C

UR

TA

IN W

ALL

SY

ST

EM

3'-6"

WA

LL P

AN

EL

SY

ST

EM

(CO

LOR

B)

GLA

ZE

D A

LUM

INU

MC

UR

TA

IN W

ALL

SY

ST

EM

A1 F

IRS

T F

LO

OR

19' -

6"

KEY PLAN

MOONEY STREET

BA

NK

ER

DR

IVE

BR

IDG

E P

AR

K A

VE

NU

E

MOONEY STREET

LONGSHORE STREET

LONGSHORE STREET

MIXED USE BUILDING TYPE 09/26/20170 4' 8' 10'6'

1/4" = 1'-0"

A501-A1WALL SECTION -SOUTH

Page 9: DRAWING INDEX A000 - A1 COVER FSP 1 TITLE SHEET FSP 2 ...€¦ · 10/17/2017  · a105 - a1 roof plan a301 - a1 south elevation a302 - a1 west elevation a303 - a1 north elevation

FIR

ST

FLO

OR

100'-0"

SE

CO

ND

FLO

OR

116'-0"

TH

IRD

FLO

OR

130'-0"

TH

IRD

FLO

OR

120'-0"

1

FO

UR

TH

FLO

OR

144'-0"

RO

OF

158'-0"

1.3

3 5/

8" C

ALC

IUM

SIL

ICA

TE

MA

NU

FA

CT

UR

ER

ED

ST

ON

E V

EN

EE

R

IG-1

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

GLA

ZIN

G

IG-1

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

GLA

ZIN

G

WA

LL P

AN

EL

FA

SC

IA /T

RIM

PA

NE

L S

YS

TE

M. (

CO

LOR

C)

IG-2

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

SP

AN

DR

EL

GLA

ZIN

G

IG-1

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

GLA

ZIN

G

IG-2

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

SP

AN

DR

EL

GLA

ZIN

G

IG-2

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

SP

AN

DR

EL

GLA

ZIN

G

IG-1

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

GLA

ZIN

G

IG-2

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

SP

AN

DR

EL

GLA

ZIN

G

IG-2

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

SP

AN

DR

EL

GLA

ZIN

G

PR

E-F

INIS

HE

D M

ET

AL

CO

PIN

G

ST

AIN

LES

S S

TE

EL

RA

ILIN

G W

ITH

GLA

SS

INF

ILL

PA

NE

LS

WA

LL P

AN

EL

SY

ST

EM

(CO

LOR

B)

IG-1

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

GLA

ZIN

G

IG-2

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

SP

AN

DR

EL

GLA

ZIN

G

13'-9" 3'-6" 3'-0" 7'-6" 3'-6" 3'-0" 7'-6" 3'-6" 3'-0" 2'-6" 7'-0" 3'-6"

CO

NC

RE

TE

TO

PP

ING

-S

LOP

E T

O D

RA

INS

3'-3" 3'-0" 7'-6" 3'-6"

CO

NC

RE

TE

FO

UN

DA

TIO

NW

ALL

- S

EE

ST

RU

CT

UR

AL

DR

AW

ING

S

IG-2

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

SP

AN

DR

EL

GLA

ZIN

G

GLA

ZE

D A

LUM

INU

MC

UR

TA

IN W

ALL

SY

ST

EM

UN

ITIZ

ED

GLA

ZE

DA

LUM

INU

M C

UR

TA

IN W

ALL

SY

ST

EM

UN

ITIZ

ED

GLA

ZE

DA

LUM

INU

M C

UR

TA

IN W

ALL

SY

ST

EM

UN

ITIZ

ED

GLA

ZE

DA

LUM

INU

M C

UR

TA

IN W

ALL

SY

ST

EM

A1 F

IRS

T F

LO

OR

19' -

6"

KEY PLAN

MOONEY STREET

BA

NK

ER

DR

IVE

BR

IDG

E P

AR

K A

VE

NU

E

MOONEY STREET

LONGSHORE STREET

LONGSHORE STREET

MIXED USE BUILDING TYPE 09/26/20170 4' 8' 10'6'

1/4" = 1'-0"

A502-A1WALL SECTION -WEST

Page 10: DRAWING INDEX A000 - A1 COVER FSP 1 TITLE SHEET FSP 2 ...€¦ · 10/17/2017  · a105 - a1 roof plan a301 - a1 south elevation a302 - a1 west elevation a303 - a1 north elevation

FIR

ST

FLO

OR

100'-0"

SE

CO

ND

FLO

OR

116'-0"

TH

IRD

FLO

OR

130'-0"

TH

IRD

FLO

OR

120'-0"

FO

UR

TH

FLO

OR

144'-0"

RO

OF

158'-0"

HG

.7

3'-0" 7'-6" 3'-6" 3'-0" 7'-6" 3'-6" 3'-0" 7'-6" 3'-6" 3'-0" 7'-6" 3'-6" 3'-0" 13'-0"

IG-1

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

GLA

ZIN

G

IG-1

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

GLA

ZIN

G

IG-2

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

SP

AN

DR

EL

GLA

ZIN

G

WA

LL P

AN

EL

FA

SC

IA /T

RIM

PA

NE

L S

YS

TE

M. (

CO

LOR

C)

WA

LL P

AN

EL

SY

ST

EM

(CO

LOR

B)

CO

NC

RE

TE

FO

UN

DA

TIO

NW

ALL

- S

EE

ST

RU

CT

UR

AL

DR

AW

ING

S

GLA

ZE

D A

LUM

INU

MC

UR

TA

IN W

ALL

SY

ST

EM

3'-0" 2'-6" 7'-0" 3'-6"

WA

LL P

AN

EL

SY

ST

EM

(CO

LOR

B)

IG-2

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

SP

AN

DR

EL

GLA

ZIN

G

IG-1

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

GLA

ZIN

G

WA

LL P

AN

EL

SY

ST

EM

(CO

LOR

B)

IG-2

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

SP

AN

DR

EL

GLA

ZIN

G

IG-1

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

GLA

ZIN

G

WA

LL P

AN

EL

SY

ST

EM

(CO

LOR

B)

IG-2

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

SP

AN

DR

EL

GLA

ZIN

G

IG-2

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

SP

AN

DR

EL

GLA

ZIN

G

IG-2

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

SP

AN

DR

EL

GLA

ZIN

G

IG-1

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

GLA

ZIN

G

WA

LL P

AN

EL

SY

ST

EM

(CO

LOR

B)

PR

E-F

INIS

HE

D M

ET

AL

CO

PIN

G

UN

ITIZ

ED

GLA

ZE

DA

LUM

INU

M C

UR

TA

IN W

ALL

SY

ST

EM

UN

ITIZ

ED

GLA

ZE

DA

LUM

INU

M C

UR

TA

IN W

ALL

SY

ST

EM

UN

ITIZ

ED

GLA

ZE

DA

LUM

INU

M C

UR

TA

IN W

ALL

SY

ST

EM

A1 F

IRS

T F

LO

OR

19' -

6"

KEY PLAN

MOONEY STREET

BA

NK

ER

DR

IVE

BR

IDG

E P

AR

K A

VE

NU

E

MOONEY STREET

LONGSHORE STREET

LONGSHORE STREET

MIXED USE BUILDING TYPE 09/26/20170 4' 8' 10'6'

1/4" = 1'-0"

A503-A1WALL SECTION -NORTH

Page 11: DRAWING INDEX A000 - A1 COVER FSP 1 TITLE SHEET FSP 2 ...€¦ · 10/17/2017  · a105 - a1 roof plan a301 - a1 south elevation a302 - a1 west elevation a303 - a1 north elevation

FIR

ST

FLO

OR

100'-0"

SE

CO

ND

FLO

OR

116'-0"

TH

IRD

FLO

OR

130'-0"

4

FO

UR

TH

FLO

OR

144'-0"

RO

OF

158'-0"

3.9

3 5/

8" C

ALC

IUM

SIL

ICA

TE

MA

NU

FA

CT

UR

ER

ED

ST

ON

E V

EN

EE

R

CO

NC

RE

TE

FO

UN

DA

TIO

NW

ALL

- S

EE

ST

RU

CT

UR

AL

DR

AW

ING

S

CO

NC

RE

TE

FO

OT

ING

-S

EE

ST

RU

CT

UR

AL

DR

AW

ING

S

UN

ITIZ

ED

GLA

ZE

DA

LUM

INU

M C

UR

TA

IN W

ALL

SY

ST

EM

IG-1

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

GLA

ZIN

G

IG-2

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

SP

AN

DR

EL

GLA

ZIN

G

WA

LL P

AN

EL

FA

SC

IA /T

RIM

PA

NE

L S

YS

TE

M. (

CO

LOR

C)

IG-2

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

SP

AN

DR

EL

GLA

ZIN

G

IG-1

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

GLA

ZIN

G

IG-2

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

SP

AN

DR

EL

GLA

ZIN

G

IG-2

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

SP

AN

DR

EL

GLA

ZIN

G

PR

E-F

INIS

HE

D M

ET

AL

CO

PIN

G

3'-3" 3'-0" 7'-6" 3'-6" 3'-0" 7'-6" 3'-6" 3'-0" 7'-6" 3'-6" 3'-0" 2'-8" 7'-0" 3'-4"

GLA

ZE

D A

LUM

INU

MC

UR

TA

IN W

ALL

SY

ST

EM

UN

ITIZ

ED

GLA

ZE

DA

LUM

INU

M C

UR

TA

IN W

ALL

SY

ST

EM

IG-2

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

SP

AN

DR

EL

GLA

ZIN

G

IG-1

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

GLA

ZIN

G

WA

LL P

AN

EL

SY

ST

EM

(CO

LOR

B)

IG-1

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

GLA

ZIN

G

IG-2

: 1"

EX

TE

RIO

RIN

SU

LAT

ED

SP

AN

DR

EL

GLA

ZIN

G A1 F

IRS

T F

LO

OR

19' -

6"

KEY PLAN

MOONEY STREET

BA

NK

ER

DR

IVE

BR

IDG

E P

AR

K A

VE

NU

E

MOONEY STREET

LONGSHORE STREET

LONGSHORE STREET

MIXED USE BUILDING TYPE 09/26/20170 4' 8' 10'6'

1/4" = 1'-0"

A504-A1WALL SECTION -EAST

Page 12: DRAWING INDEX A000 - A1 COVER FSP 1 TITLE SHEET FSP 2 ...€¦ · 10/17/2017  · a105 - a1 roof plan a301 - a1 south elevation a302 - a1 west elevation a303 - a1 north elevation
Page 13: DRAWING INDEX A000 - A1 COVER FSP 1 TITLE SHEET FSP 2 ...€¦ · 10/17/2017  · a105 - a1 roof plan a301 - a1 south elevation a302 - a1 west elevation a303 - a1 north elevation