DESIGN CRITERIA AND LOAD COMPUTATION
Proposed Project: Construction of Two-Storey Staff Housing
Location: Quezon City
Owner: DPWH-Region IV-A
I. Materials:
a. Concrete f’c = 20.7 MPa (3,000 psi at 28 days)
b. Steel Reinforcement fy = 275 MPa (40,000 psi)
c. Structural Steel Shapes : fy = 248 MPa (36,000 psi)
II. Codes & Specifications:
a. National Building Code of the Philippines
b. Implementing Rules and Regulations, NBCP
c. National Structural Code of the Philippines 2001 (NSCP C101-01)
III. Loads:
a. Earthquake Load Zone IV – UBC 1997 STAAD Generated Load
b. Wind load Zone II V = 200 kph
c. Roofing Dead Load:
1. Roof Sheeting = 0.10 kPa
2. Purlins @ 0.70 meter o.c. x 0.03 kN/m = 0.043 kPa
3. Ceiling = 0.25 kPa
4. Truss selfweight = 0.50 kPa (estimated)
d. Floor Dead Load (Superimposed)
1. Floor finish = 1.20 kPa
2. Ceiling and utilities = 0.60 kPa
3. Exterior masonry walls (150mm) = 3.60 kPa
4. Exterior masonry walls with large opening = 2.40 kPa
5. Interior masonry walls (100mm) = 2.50 kPa
Page 1 of 3
6. Movable Partition allowance = 1.0 kPa
e. Floor Live Load = 1.9 kPa
f. Corridor and Stair Live Load = 4.8 kPa
g. Roof Live Load = 4.8 kPa
IV. DEAD LOAD COMPUTATIONS (Superimposed)– Ground Floor Framing
Ground Beams will serve as Tie Beams / Intermediate Column Support
and therefore shall carry only it’s own weight.
Walls will be carried by wall footings.
V. DEAD LOAD COMPUTATIONS (Superimposed) – 2ND, Floor Framing
a. For 6.25m x 5.0 Two Way Slab
LS = {1.8 kPa x 5.0.m/3} {3.0 –(5.0m/6.25m)2}/2 = 3.54 kN/m
SS = 1.8 kPa x 5.0m/3 = 3.0 kN/m
b. For 6.25m x 4.0 Two Way Slab
LS = {1.8 kPa x 4.0m/3} {3.0 –(4.0m/6.25m)2}/2 = 3.11 kN/m
SS = 1.8 kPa x 4.0m/3 = 2.40 kN/m
c. For 5.0m x 2.5 Two Way Slab
LS = {1.8 kPa x 2.5m/3} {3.0 –(2.5m/5.0m)2}/2 = 2.06 kN/m
SS = 1.8 kPa x 2.5m/3 = 1.50 kN/m
d. For 4.0m x 2.5 Two Way Slab
LS = {1.8 kPa x 2.5m/3} {3.0 –(2.5m/4.0m)2}/2 = 1.96 kN/m
SS = 1.8 kPa x 2.5m/3 = 1.50 kN/m
e. For Beams carrying Exterior walls
W = 3.6kPa x 2.50m high = 9.0 kN/m
f. For Beams carrying Exterior walls with wide opening
W = 2.4kPa x 2.50m high = 6.0 kN/m
g. For Beams carrying Interior walls
W = 2.5kPa x 2.5m high ave. = 6.25 kN/m
h. For beams carrying balcony railings, say 1.1 m high
W = 2.5 kN/m x 1.1m = 2.75 kN/m
i. For Beams carrying Stairs
Page 2 of 3
VI. DEAD LOAD COMPUTATIONS (Superimposed) – Roof Framing
a. 6.25 + 2.5m Truss Span,
Roof beam load =0.90kPa x 8.75/2 m = 3.94 kN/m
VII. LIVE LOAD COMPUTATIONS – 2ND, Floor Framing
wLL = 1.90 kPa – computer generated
a. For Beams carrying Stairs
VIII. ROOF LIVE LOAD COMPUTATIONS – Roof Framing
b. 6.25 + 2.5m Truss Span
Roof load =1.0kPa x 8.75/2 m = 4.38 kN/m
Refer to STAAD PRINTOUT for design and analysis results.
Prepared by:
NOLI E. PALAD M.PICE M.ASEP M.CCMECivil/Structural EngineerPRC # 20659PTR # 2725146Issued on Jan. 11, 2010Issued at Norzagaray, BulacanTIN # 183-328-567
Page 3 of 3
6.12kN/m2
4.2kN/m2
3.0m
13.04 kN/m
11.20 kN/m1.4 m
4.80kN/m2
4.8kN/m2
3.0m
10.56 kN/m
10.56 kN/m1.4 m