DISCONNECTING EARTHING DEVICE 6x-Ø15 · aks 26/03/2019 sheet 4 of 16 note: 1. all dimensions in mm...
Transcript of DISCONNECTING EARTHING DEVICE 6x-Ø15 · aks 26/03/2019 sheet 4 of 16 note: 1. all dimensions in mm...
DT.
D
C
STATUS
REV./ ALT.
REF. NO. DESCRIPTION
APPD. BY DATE
SUPERSEDES
LW70020 SHEET 1
SUPERSEDED BY
REF :-
SCALE :- 1 : 1
APPROVED BY :-
( FOR D. G. )
SWITCH BOARD CABINET - S1 SPEC I84
(SWITCH BOARD CABINET - S1 FOR LHB AC - EOG TYPE COACHES)
RDSO/PE/SK/AC/0205-2019 (Rev. 0)
AD
AKS
26/03/2019
SHEET 1 OF 16
NOTE:
1. ALL DIMENSIONS IN MM
2. FOR UNTOLERANCED DIMENSIONS REFER MDG0008
RESEARCH DESIGN STANDERDS ORGANISATION LUCKNOW
1280
85
1180
23
1095
71
8
600 20
100
600
475
15
90
6
6
18
50
85
622
10
0
55269215
B
B
A
A
12
3
10
0
105
5
15
23
40
0400
95
95
552
155
0±0.5
16
23±0
.5
8x-Ø
15
28
5±0
.5
68
9±0
.5
30 182 330 50 135 50 325
200±0.5 495±0.5 495±0.5
55
0
60
0
50
1280 1.61.6
Ø
1
5
6
x
-
Ø
1
5
LIFTING HOOK
TOP COVER
20
SPACE FOR
FUTURE USE
DISCONNECTING
&
EARTHING DEVICE
CC
SECTION B-B SECTION A-A
SECTION C-C
30
DRAIN PIPE
DRAIN PIPE
50
14
DRAIN PIPE
RC FILTER
MCB'S FOR
CAPACITOR BANK
EARTHING BUSH M8
(Ø20x15, 4 Nos.)
DT.
D
C
STATUSREV./ ALT.
REF. NO. DESCRIPTION
APPD. BY DATE
SUPERSEDED BY
REF :-
SCALE :- 1 : 1
APPROVED BY :-
( FOR D. G. )
AD
AKS
SHEET 2 OF 16
26/03/2019
FRAME COMPLETE SWITCH BOARD CABINET - S1 SPEC I84
( SWITCH BOARD CABINET - S1 FOR LHB AC - EOG TYPE COACHES)
DRG NO. RDSO/PE/SK/AC/0205-2019 (Rev. - 0)
RESEARCH DESIGN STANDERDS ORGANISATION LUCKNOW
SUPERSEDES
LW70020 SHEET 2
1850
1280
A
A
CC
B
B 600
SECTION A-A
200±0.5 495±0.5 495±0.5
SECTION C-C
580
600
480
200
SECTION B-B
1280
285±0.5
689±0.5
1623±0.5
1550±0.5
1850
430
30
250
50
3030
SECTION D-D
5625013550325
1280
50
600
150
6
x
-
Ø
1
5
200±0.5495±0.5 495±0.5
100
50
90
RC FILTER
222
69
340
719
380 185 375
173
32
445
238
280
110
106
106
480
55
STOPER BKT. FOR
PUSH LOCK
100
595 30
30
525
1850
1050
50
688
65
1250±0.5
LED LIGHT FOR CUBICLE
STOPER BKT. FOR
PUSH LOCK
520
650
50
MCB'S FOR
CAPACITOR BANK
30
550
25
SPACE FOR
FUTURE USE
DISCONNECTING
&
EARTHING DEVICE
MMR
NOTE:
1. ALL DIMENSIONS IN MM
2. FOR UNTOLERANCED DIMENSIONS REFER MDG0008
DISCONNECTING
&
EARTHING DEVICE
D
D
SPACE FOR
FUTURE USE
PG 29 (10 Nos.) FOR
POWER & CONTROL CABLE
WELD NUT
600
SWITCH BOARD CABINET - S1 SPEC I84
(SWITCH BOARD CABINET - S1 FOR LHB AC - EOG TYPE COACHES)
DT.
D
C
STATUSREV./ ALT.
REF. NO. DESCRIPTION
APPD. BY DATE
SUPERSEDES
RDSO/PE/SK/AC/0191-2015
SHEET 1 OF 5
SUPERSEDED BY
REF :-
SCALE :- 1 : 1
APPROVED BY :-
( FOR D. G. )
MOUNTING PLATE - RIGHT SWITCH BOARD CABINET - S1 SPEC I84
(SWITCH BOARD CABINET - S1 FOR LHB AC - EOG TYPE COACHES)
DRG NO. RDSO/PE/SK/AC/0205-2019 (Rev. 0)
AD
AKS
26/03/2019
SHEET 3 OF 16
NOTE:
1. ALL DIMENSIONS IN MM.
2. FOR UNTOLERANCED DIMENSIONS REFER MDG0008.
3. EDGE PROTECTION SLEEVE PROVIDE ON ALL CUTOUT
RESEARCH DESIGN STANDERDS ORGANISATION LUCKNOW
1098
107158 185 216 235
100
2
58
1
2
63
1
1048
F45
F46
F47
F48
F49
F44
120 120 120 120 120 120 120 120
25 =
=
12
5
16
4
22
88
0
1048
1098
PG 29 (8 Hole)
PG 29
(2 Hole)
ME
TA
LIC
E
ND
C
LA
MP
A
T
BO
TH
S
ID
E O
F C
ON
NE
CT
OR
POLYCARBONATE SHEET
10
0
STUDS FOR FIXING
M8x200(04 Nos.) POLYCARBONATE SHEET
2003
S. NO.
AS PER REF.
DRG.
REVISED DIM.
REMARKS
1.
A
129.00 107.00
RMPU CONTACTOR HAVE BEEN SHIFTED TO
UPPER AREA K41 K42 CONTACTOR HAVE
BEEN SHIFTED TO LOWER AREA TO AVOID
CRISS CROSS OF CABLES
2. B 181.50 158.00
3. C 160.00 185.00
4. D 195.00 216.00
5. E 1100.00 1098.00
6. F 1050.00 1048.00FOR EASILY FITMENT OF PLATE
FOR EASILY FITMENT OF PLATE
DT.
D
C
STATUSREV./ ALT.
REF. NO. DESCRIPTION
APPD. BY DATE
SUPERSEDED BY
REF. :
SCALE :- 1 : 1
APPROVED BY :-
( FOR D. G. )
MOUNTING PLATE - LEFT SWITCH BOARD CABINET - S1 SPEC I84
(SMART SWITCH BOARD CABINET - S1 FOR LHB AC - EOG TYPE COACHES)
DRG NO. RDSO/PE/SK/AC/0205-2019 (Rev. 0)
AD
AKS
26/03/2019
SHEET 4 OF 16
NOTE:
1. ALL DIMENSIONS IN MM
2. FOR UNTOLERANCED DIMENSIONS REFER MDG0008.
3. EDGE PROTECTION SLEEVE PROVIDE ON ALL CUTOUT
RESEARCH DESIGN STANDERDS ORGANISATION LUCKNOW
SUPERSEDES
RDSO/PE/SK/AC/0191-2015
SHEET 2 OF 5
105 160 186 219 235
1048
1098
10
0
F 42
F 43
= 120 120 120 120 120 120 120 120 =
=1
25
12
51
25
12
5=
2
75
12
87
5
27
100
63
1
58
1
PG 29 (8 Hole)
PG 29
(1 Hole)
ME
TA
LIC
E
ND
C
LA
MP
A
T
BO
TH
S
ID
E O
F C
ON
NE
CT
OR
1048
200
POLYCARBONATE SHEET
STUDS FOR FIXING
M8x200(04 Nos.)
3
S. NO.
AS PER REF.
DRG.
REVISED DIM.
REMARKS
1.
A
120.00 120.00
RMPU CONTACTOR HAVE BEEN SHIFTED TO
UPPER AREA K43 K44 CONTACTOR HAVE
BEEN SHIFTED TO LOWER AREA TO AVOID
CRISS CROSS OF CABLES
2. B 200.00 H 120.00
3. C 200.00 H 120.00
4. D 200.00 H 120.00
5. E 200.00 H 120.00
6. F 124.00 H 120.00FOR EASILY FITMENT OF PLATE
FOR EASILY FITMENT OF PLATE
DT.
D
C
STATUS
REV./ ALT.
REF. NO. DESCRIPTION
APPD. BY DATE
SUPERSEDED BY
REF :-
SCALE :- 1 : 1
APPROVED BY :-
( FOR D. G. )
MPCB / MCB HOLDER - LEFT SWITCH BOARD CABINET - S1 SPEC I84
(SWITCH BOARD CABINET - S1 FOR LHB AC - EOG TYPE COACHES)
DRG NO. RDSO/PE/SK/AC/0205-2019 (Rev. 0)
AD
AKS
26/03/2019
SHEET 5 OF 16
575
DESIGNATED LABLE
METALIC END CLAMP AT
BOTH SIDE OF MCB / MPCB
22
HINGES
PVC CABLE ALLEY / DUCT
70
50
30
50
222
F 17 F 18 F 19 F 16 F 20
F 2 F 9 F 11 F 12 F 13
F 14
F 1 F 3 F 5 F 6 F 7 F 15F 8 F 92
16
140
40
==
DIN RAIL
30
30
8
NOTE:
1. ALL DIMENSIONS IN MM
2. FOR UNTOLERANCED DIMENSIONS REFER MDG0008
3. EDGE PROTECTION SLEEVE PROVIDE ON ALL CUTOUT.
8146
95
40
250 2520
CHANEL FOR CABLE ALLEY MTG.
40
30
RESEARCH DESIGN STANDERDS ORGANISATION LUCKNOW
SUPERSEDES
RDSO/PE/SK/AC/0191-2015
SHEET 3 OF 5
3
COMPUTER GENERATED
DESIGNATED LABLE
DIN RAIL
22
PVC CABLE ALLEY
METALIC END CLAMP AT
BOTH SIDE OF MCB / MPCB
HINGES
30
50
30
50
222
F 25F 24 F 26 F 27 F 28 F 29 F 30 F 31 F 32 F 33 F 34 F 35
F 39 F 40 F 41
F 98 F 99 F 100
F 58 F 59 F 36 F 37 F 38
F 97
525
16
140
==
40
30
30
146
DT.
D
C
STATUS
REV./ ALT.
REF. NO. DESCRIPTION
APPD. BY DATE
SUPERSEDED BY
REF :-
SCALE :- 1 : 1
APPROVED BY :-
( FOR D. G. )
CONNECTING BLOCKS - RIGHT (X-1.2) SWITCH BOARD CABINET - S1 SPEC I84
(SWITCH BOARD CABINET - S1 FOR LHB AC - EOG TYPE COACHES)
AD
AKS
26/03/2019
SHEET 6 OF 16
NOTE:
1. ALL DIMENSIONS IN MM
2. FOR UNTOLERANCED DIMENSIONS REFER MDG0008.
3. EDGE PROTECTION SLEEVE PROVIDE ON ALL CUTOUT
4. MCB F`64 F165 F166 F167 F168 F169 FOR CCTV AUTOMATIC SLIDING DOOR INFOTAINMENT
LED LIGHT SPARE SHALL BE FITTED AT SUITABLE LOCATION IN SBC
210 25
40
95
25
CHANEL CABLE ALLEY MTG.
DRG NO. RDSO/PE/SK/AC/0205-2019 (Rev. 0)
RESEARCH DESIGN STANDERDS ORGANISATION LUCKNOW
SUPERSEDES
RDSO/PE/SK/AC/0191-2015
SHEET 4 OF 5
DT.
D
C
STATUS
REV./ ALT.
REF. NO. DESCRIPTION
APPD. BY DATE
SUPERSEDES
LW70020 SHEET 7
SUPERSEDED BY
REF :-
SCALE :- 1 : 1
APPROVED BY :-
( FOR D. G. )
DOOR COMPLETE - LEFT SWITCH BOARD CABINET - S1 SPEC I84
(SWITCH BOARD CABINET - S1 FOR LHB AC - EOG TYPE COACHES)
DRG NO. RDSO/PE/SK/AC/0205-2019 (Rev. 0)
AD
AKS
26/03/2019
SHEET 7 OF 16
RESEARCH DESIGN STANDERDS ORGANISATION LUCKNOW
540
266
322
25 49
36
25
547.5
547.5
100
100
270
320
20
35
614 12
20
10
614
2
P3P2P1
S1 S2
S12
S13
S14
6767 50
5067
67
45
90
11511511470 90
CODIFICATION CHART
FOR
CONTACTORS & MPCB, MCB'S
DETAILS
Ø
2
2
.5
POLYCARBONATE SHEET
28
40
EARTHING BUSH M8X12
NOTE:
1. ALL DIMENSIONS IN MM.
2. FOR UNTOLERANCED DIMENSIONS REFER MDG0008.
PUSH LOCK
PUSH LOCK
DT.
D
C
STATUS
REV./ ALT.
REF. NO. DESCRIPTION
APPD. BY DATE
SUPERSEDES
LW70020 SHEET 8
SUPERSEDED BY
REF :-
SCALE :- 1 : 1
APPROVED BY :-
( FOR D. G. )
DOOR COMPLETE - RIGHT SWITCH BOARD CABINET - S1 SPEC I84
(SWITCH BOARD CABINET - S1 FOR LHB AC - EOG TYPE COACHES)
AD
AKS
26/03/2019
SHEET 8 OF 16
FRONT SIDE VIEW
1095
544
240
470
30
501
30
200
2549
300
100
120
52
30
30
==
MA
IN
L
OC
K
PUSH LOCK
POLYCARBONATE TRANSPARENTSHEET 3.0 MM THK.
POLYCARBONATE TRANSPARENTSHEET 3.0 MM THK.
POLYCARBONATE TRANSPARENTSHEET 3.0 MM THK.
A
A
45 MAX.
20
35 MAX.
SECTION A-A
450
54
54
67 38 67 38 6768
207
111
4668
85
80
70
70
70
70
60
46686868
460
55
74.5
74.5
86.5
9.5
10 MIN.
25
28
40
40
36
BACK SIDE VIEW
EARTHING BUSH M8x12
P8 P9 P10
S3 S4
S5
H6
H9
H7
S10 S9 S8
H1H2H3
H4H5H8
H10H-SP
H-SP
S6S7
SPACE FOR AC CONTROLLER PANEL
(CUT OUT SIZE 130X430 MM)
CU
T O
UT
S
IZ
E F
OR
PU
MP
C
ON
TR
OLE
R
(190x130 M
M)
PUSH LOCK
79
3
20
POLYCARBONATE SHEET
NOTE:
1. ALL DIMENSIONS IN MM
2. FOR UNTOLERANCED DIMENSIONS REFER MDG0008.
S. NO.
AS PER REF.
DRG.
REVISED DIM.
REMARKS
1.
A
33.0 49.0FOR EASILY FITMENT OF PUSH LOCK
2. B 483.0 470.0FOR EASILY FITMENT OF PUSH LOCK
3. C 21.0 45.0 REQUIRED FOR SYMMETRY OF LHS MPCB PLATE
4. D 40.0 28.0FOR EASILY FITMENT OF PUSH LOCK
5. E 25.0 40.0
FOR PROPER LOCKING ARRANGEMENT OF PUSH LOCK
6. F 20.0 10.0FOR EASILY TIGHTENING OF HINGE SCREW
7. G 40.0 25.0
FOR PROPER LOCKING ARRANGEMENT OF PUSH LOCK
8. H 21.0 36.0 FOR PROPER LOCKING ARRANGEMENT OF PUSH LOCK
9. I 52.0 54.0DUE TO EDGE PROTECTION SLEEVE
10. J 75.0 73.0
DUE TO EDGE PROTECTION SLEEVE
A
B
C
D
E
F
G
H
I
I
73
J
DRG NO. RDSO/PE/SK/AC/0205-2019 (Rev. 0)
RESEARCH DESIGN STANDERDS ORGANISATION LUCKNOW
EL/7.1.108/ SBC LOCK POSITION STANDARISED
244
2
DT.
D
C
STATUS
REV./ ALT.
REF. NO. DESCRIPTION
APPD. BY DATE
SUPERSEDES
LW70020 SHEET 9
SUPERSEDED BY
REF :-
SCALE :- 1 : 1
APPROVED BY :-
( FOR D. G. )
DOOR COMPLETE (BOTTOM) - LEFT SWITCH BOARD CABINET - S1 SPEC I84
(SWITCH BOARD CABINET - S1 FOR LHB AC - EOG TYPE COACHES)
DRG NO. RDSO/PE/SK/AC/0205-2019 (Rev. 0)
AD
AKS
26/03/2019
SHEET 9 OF 16
2
582100
718
460
====
20
100
100
684
100 582
14
284
MA
IN
LO
CK
STIFFNER
20
40
20
HINGE
A
1.6
20
LO
CK
IN
G R
OD
22
10
30
DETAIL - A
8
50
STAINLESS STEEL
STIFFNER
NOTE:
1. ALL DIMENSIONS IN MM.
2. FOR UNTOLERANCED DIMENSIONS REFER MDG0008.
7373
6
20
20
1.6
EARTHING BUSH
M8x12 (Ø20x12)
1.6
1.6
127
RESEARCH DESIGN STANDERDS ORGANISATION LUCKNOW
64
DT.
D
C
STATUS
REV./ ALT.
REF. NO. DESCRIPTION
APPD. BY DATE
SUPERSEDED BY
REF :-
SCALE :- 1 : 1
APPROVED BY :-
( FOR D. G. )
DOOR COMPLETE (BOTTOM) - RIGHT SWITCH BOARD CABINET - S1 SPEC I84
(SWITCH BOARD CABINET - S1 FOR LHB AC - EOG TYPE COACHES)
AD
AKS
26/03/2019
SHEET 10 OF 16
718
100
100
MAIN LOCK
AA
DO
OR
LO
CK
IN
G R
OD
544
20
40
552
20
20
20
SECTION A-A
HINGE
A
=
=
262
EARTHING BUSH
M8x12 (Ø20x12)
STIFFNER
10
22
1.6
30
DETAIL A
1.6
STAINLESS STEEL
STIFFNER
NOTE:
1. ALL DIMENSIONS IN MM
2. FOR UNTOLERANCED DIMENSIONS REFER MDG0008
1.6
107
107
70
73
= 73 = 73
6
20
BACK VIEW
DRG NO. RDSO/PE/SK/AC/0205-2019 (Rev. 0)
RESEARCH DESIGN STANDERDS ORGANISATION LUCKNOW
SUPERSEDES
LW70020 SHEET 10
20
30
20
DT.
D
C
STATUS
REV./ ALT.
REF. NO. DESCRIPTION
APPD. BY DATE
SUPERSEDES
LW70020 SHEET 11
SUPERSEDED BY
REF :-
SCALE :- 1 : 1
APPROVED BY :-
( FOR D. G. )
ROTATING FRAME FOR SUB - RACK SWITCH BOARD CABINET - S1 SPEC I84
(SWITCH BOARD CABINET - S1 FOR LHB AC - EOG TYPE COACHES)
DRG NO. RDSO/PE/SK/AC/0205-2018 (Rev. 0)
AD
AKS
26/03/2019
SHEET 11 OF 16
NOTE:
1. ALL DIMENSIONS IN MM.
2. FOR UNTOLERANCED DIMENSIONS REFER MDG0008.
3. EDGE PROTECTION SLEEVE PROVIDE ON CUTOUT.
RESEARCH DESIGN STANDERDS ORGANISATION LUCKNOW
340
550
64
57
465
40
40
20
88
550
20
301
30
88
15
3
355
301
30
SPACE FOR
ANTI SKID DEVICE
SPACE FOR PICCU WITH
SUITABLE ARRANGEMENT
(370x260x140)
47.5
Ø
6
.
5
HINGE
EA
RT
HIN
G B
US
H M
6X
12
40
501.85
1217
480159.5
A
SECTION A-A
K1 K2
T2 T3
T4
F90
F91
F93
F94
F95
F13
F14
F40
125 AMP. FUSE
F50
F51
F52
F53
F54
F55
NE
TU
RA
L T
ER
MIN
AL
FO
R T
/R
O
UT
PU
T
Ø70
A
20
HOG CONTROL TRANSFORMER
WITH FUSE (MOUNTED ON TOP)
HOG CONTROL TRANSFORMER
WITH FUSE (MOUNTED ON TOP)
FUSE 1 AMP.
80.5
38.5
55
300
F96
55.5
242
20
430165
15
2
2
SLIDING ARRANGEMENT WITH INSULATED HANDLE
SLIDING ARRANGEMENT WITH INSULATED HANDLE
DT.
D
C
STATUS
REV./ ALT.
REF. NO. DESCRIPTION
APPD. BY DATE
SUPERSEDES
LW70020 SHEET 13
SUPERSEDED BY
APPROVED BY :-
( FOR D. G. )
BOTTOM CONTACTORS (K1 & K2) & FUSE MOUNTING PLATE - LEFT & RIGHT
SWITCH BOARD CABINET - S1 SPEC I84 (SWITCH BOARD CABINET - S1 FOR LHB AC - EOG TYPE COACHES)
AD
AKS
26/03/2019
SHEET 12 OF 16
NOTE:
1. ALL DIMENSIONS IN MM.
2. FOR UNTOLERANCED DIMENSIONS REFER MDG0008.
REMARKS
REF :-
RDSO/PE/SK/AC/0205-2019 (Rev. 0)
RESEARCH DESIGN STANDERDS ORGANISATION LUCKNOW
DT.
D
C
STATUS
REV./ ALT.
REF. NO. DESCRIPTION
APPD. BY DATE
SUPERSEDES
LW70020 SHEET 14
SUPERSEDED BY
REF :-
SCALE :- 1 : 1
APPROVED BY :-
( FOR D. G. )
FRAME FOR HVAC CONTROLLER SWITCH BOARD CABINET - S1 SPEC I84
(SWITCH BOARD CABINET - S1 FOR LHB AC - EOG TYPE COACHES)
RDSO/PE/SK/AC/0205-2019 (Rev. 0)
AD
AKS
26/03/2019
SHEET 13 OF 16
NOTE:
1. ALL DIMENSIONS IN MM
2. FOR UNTOLERANCED DIMENSIONS REFER MDG0008.
3. EDGE PROTECTION SLEEVE PROVIDE.
RESEARCH DESIGN STANDERDS ORGANISATION LUCKNOW
HEX.HD.SCREW M8X12
# HEX.HD.SCREW M4X30
PLAIN WASHER 4.3
SPRING WASHER M4
EDGE PROTECTION SLEEVE
SYMBOL OF EARTHING
100
330
346
500
AIR CONDITIONING
CONTROL PANEL
(RCF SCOPE)
AIR CONDITIONING
CONTROL PANEL
(RCF SCOPE)
07
0 12
15
1 19
0 11
10
0 19
03
0 15
0 14
STAT 1
1 13
11
1 16
06
0 18
1 1818
14
0 17
1 17
16
0 13
0 20
1 14
001
110
05
17
1 11
13
1 15
08
1 20
#
0 16
02
01
RUN
19
04
STAT 2
09
12 1 12
305
215
#
16
95
60
38
20
2
HINGES
==
DT.
D
C
STATUS
REV./ ALT.
REF. NO. DESCRIPTION
APPD. BY DATE
SUPERSEDES
LW70020 SHEET 11
SUPERSEDED BY
REF :-
SCALE :- 1 : 1
APPROVED BY :-
( FOR D. G. )
CONNECTING BLOCKS - RIGHT (X - 1.2), LEFT (X - 1.2), & X3 SWITCH BOARD CABINET - S1 SPEC I84
( SWITCH BOARD CABINET - S1 FOR LHB AC - EOG TYPE COACHES)
DRG NO. RDSO/PE/SK/AC/0205-2019 (Rev. 0)
AD
AKS
26/03/2019
SHEET 14 OF 16
NOTE:
1. FOR UNTOLERANCED DIMENSIONS REFER MDG0008.
RESEARCH DESIGN STANDERDS ORGANISATION LUCKNOW
EL/7.1.108/ SBC
1048
1048
250
300
= =
115.5
TERMINAL CONNECTOR
FOR BATTERY CHARGER
CONNECTING BLOCKS - RIGHT (X - 1.2)
CONNECTING BLOCKS - LEFT (X - 1.2)
CONNECTION BLOCK FOR RBC CUM EBC - X3
DT.
D
C
STATUS
REV./ ALT.
REF. NO. DESCRIPTION
APPD. BY DATE
SUPERSEDES
LW70020 SHEET 16
SUPERSEDED BY
REF :-
SCALE :- 1 : 1
APPROVED BY :-
( FOR D. G. )
CODIFICATION CHART AND NAME PLATE SWITCH BOARD CABINET - S1 SPEC I84
(SWITCH BOARD CABINET - S1 FOR LHB AC - EOG TYPE COACHES)
AD
AKS
26/03/2019
SHEET 15 OF 16
NOTE:
1. FOR UNTOLERANCED DIMENSIONS REFER MDG0008.
RDSO/PE/SK/AC/0205-2019 (Rev. 0)
RESEARCH DESIGN STANDERDS ORGANISATION LUCKNOW
750 VOLTS
DANGER
750 IN LOCAL LANGUAGE
(HINDI NUMERALS)
WHEREEVER APPLICABLE
EQUIVALENT OF VOLT
IN
LOCAL LANGUAGE
EQUIVALENT OF DANGER
IN
LOCAL LANGUAGE
200
250
505
485
DT.
D
C
STATUS
REV./ ALT.
REF. NO. DESCRIPTION
APPD. BY DATE
SUPERSEDES
LW70020 SHEET 17
SUPERSEDED BY
REF :- EL/7.1.108/ SBC
SCALE :- 1 : 1
APPROVED BY :-
( FOR D. G. )
MANUFACTURER NAME PLATE - S1 SPEC I84
(SWITCH BOARD CABINET - S1 FOR LHB AC - EOG TYPE COACHES)
DRG NO. RDSO/PE/SK/AC/0205-2019 (Rev. 0)
AD
AKS
26/03/2019
SHEET 16 OF 16
NOTE:-
1. ALL DIMENSIONS IN MM.
RESEARCH DESIGN STANDERDS ORGANISATION LUCKNOW
LOGOMANUFACTURER NAME
SPECIFICATION NO.
P.O No.
Sl. No.
YEAR MONTH
MANUFACTURER ADDRESS
10
0
150