Direct Fired, Electric, Indirect Fired, Radiant ...

9
HEATING Call 888-777-2700 for rates and reservations 20 HEATING Direct Fired, Electric, Indirect Fired, Radiant + Speciality, Flameless, Self-Contained, and Hydronic Surface

Transcript of Direct Fired, Electric, Indirect Fired, Radiant ...

Page 1: Direct Fired, Electric, Indirect Fired, Radiant ...

HEA

TIN

G

Call 888-777-2700 for rates and reservations20

HEATING Direct Fired, Electric, Indirect Fired, Radiant + Speciality,

Flameless, Self-Contained, and Hydronic Surface

Page 2: Direct Fired, Electric, Indirect Fired, Radiant ...

HercRentals.com

HEATIN

G

21

HEATING

HEAT APPLICATION GUIDE

ELECTRIC SELF-CONTAINED

HYDRONIC SURFACEDIRECT

FLAMELESS

INDIRECT

Portable Electric Heaters Industrial Electric Heaters

Portable electric heaters provide safe, fast, dry, odorless heat for enclosed spaces. Available in ranges from 1.6 kW to 150 kW. Ideal for job sites or offices, where 100% dry heat and flameless operations are required.

Advantages• 100% clean, dry heat - no moisture • No exhaust - can be used in confined spaces• No need for gas line or propane• Quiet operation

Applications• Heating for contractors and special events• Emergency situations - heat loss, thawing of frozen pipes

Self-Contained units have a built in generator for easy start up. Tow to the site and start it up!

Advantages• Powerful - provides clean, safe, reliable air• Ducting long distances with minimal loss of pressure or temperature• Push-button controls make units easy to use• Flameless options are also available• Built-in generator

Applications• Ground thawing• Cold weather concrete warming/curing• Pre-pour warming• Ground frost prevention• Multi-zone layout: create higher return temps for a quicker more-effective thaw• Other heat applications for extreme cold

Trailer mounted hydronic heaters are self-contained so they can operate in remote job sites. Powerful burners heat up fluid that is pumped through 5/8 inch hose (the heating circuit) up to 3,000 ft in length.

Advantages• Long run times, maximized efficiency• Closed-loop system: vertically or sideways• On-board fuel heater• Spill containment and safety shut down sensors

Applications• Ground thawing• Cold weather concrete warming/curing• Pre-pour warming• Ground frost prevention• Higher return temps for a quicker thaw

Direct fired portable heaters are generally used in farms, warehouses, garages and construction sites. Proper ventilation of the heated area is necessary.

Advantages• Kerosene and propane forced air heaters are portable and easy to operate• Extends heat into wide areas for a comfortable work environment in the harshest conditions

Applications• Farms, workshops, warehouses, garages and construction sites with proper ventilation

Flameless heaters provide highly efficient heated air output with unprecedented safety in portable DOT-approved trailer mounted packages. These heaters are capable of ducting long distances with minimal loss of air pressure or outlet temperature.

Advantages• Ideal for potentially volatile applications where "no open flame" is a requirement• Develop very high CFM and static pressure to maximize heat delivery• Engine driven

Applications• Oil and Gas• Mining• Construction• Restoration

Portable indirect fired heaters operate like a mobile furnace with a fan forcing air over a heat exchanger where internal combustion occurs and fumes are exhausted through a stack.

Advantages• 100% clean, dry heat with no open flame• Exhaust vented outside• Flexible fuel options: oil, diesel, propane (LP), natural gas (NG), or dual fuel (LP/NG)

Applications• Safe for use around people and animals• Emergency situations: heating system is under repair or drying applications• Special events: ducting allows units to be placed outside and away from tents or temporary structures with warm air ducted into interior areas

Page 3: Direct Fired, Electric, Indirect Fired, Radiant ...

HEA

TIN

G

Call 888-777-2700 for rates and reservations22

DIRECT FIRED

MI-T-M/MH-0150-LMTO

FLAGRO/F-1500T

• 150,000 BTU propane forced air • Adjustable thermostat • Requires (1) 100 lb. LP cylinder

• 1,500,000 BTU LP or natural gas forced air• High and low fire output heat capacity• Fuel selector valve to change fuel supply LP/NG

MI-T-M/MH-0190-0M10

• 190,000 BTU kerosene forced air • Fuel gauge • 13 gallon on-board fuel tank

MI-T-M/MH-0375-LM10

• 375,000 BTU propane forced air• Adjustable thermostat • Requires (2) 100 lb. LP cylinders

FLAGRO/FMA-2300

• 2,300,000 BTU LP or natural gas forced air• Mild weather stat: to prevent heating in mild weather• Requires 230V 3PH 35A for fan operation

Not for use in residential living

areas or inadequately ventilated areas. Must

be plugged into an approved standard electrical outlet for

operation.

[

[

HEATING

MAKE MODEL TYPE CFM BTU HEATING AREA FUEL TANK CONSUMPTION RUN TIME VOLTAGE DIMENSIONS (LWH) WEIGHT (DRY) CAT-CLASS

MI-T-M MH-0150-LMTO Propane 400 150,000 3,800 sq ft 100 gal external 6.9 lbs/hr 18 hrs 120V 25.1" x 8" x 15.4" 23 lbs 715-0430

MI-T-M MH-0190-0M10 Kerosene 630 190,000 4,000 sq ft13 gal on

board1.42 gal / hr 9.1 hrs 120V 42" x 24" x 26" 58 lbs 715-0450

MI-T-M MH-0375-LM10 Propane 1,500 375,000 9,000 sq ft (2) 100 gal external 17.4 lb/hr 11.5 hrs 120V 34" x 12.6" x 18.5" 41 lbs 715-0460

Flagro F-1500T LP/NG 7,000 1,500,000 19,000 sq ft External 16.24 gal LP / 1500 CFH

Depends on tank cap 115V 61" x 29" x 38" 314 lbs 715-0550

Flagro FMA-2300 LP/NG 15,000 2,300,000 30,000 sq ft External 25.11 gal LP / 2300 CFH

Depends on tank cap

230 Volt / 3PH / 35 Amp

96" x 47" x 51" 1,900 lbs 715-0560

Page 4: Direct Fired, Electric, Indirect Fired, Radiant ...

HercRentals.com

HEATIN

G

23

HEATING

ELECTRIC

CAMPO/ED1.5E

CAMPO/EB18E

• 5,100 BTU• 13 AMPS• Input power required: 120V 13.5A 1PH

• 65,000 BTU• Built in thermostat control • Input power required 208/240 V 1PH 86A

or 3 PH 50 A

CAMPO/EB6/9E

CAMPO/EB60E

• BTU 20,500/30,700 dual output• Keep second point• Input power required 24.5A/36.5A 1PH

• 205,000 - 136,500 BTU dual output• Recirculating capabilities • Input power required: 240/480V 144/72A 3PH

PHOENIX/FIREBIRD COMPACT 20

FOSTORIA /SALAMANDER FES-1548-3E

• 20,000 BTU max output • Remote thermostat • Generate 5,000 BTU per each 120V 12 Amp 1PH

• 102,390 BTU • 3-position switch: Off/Thermostat control• Continuous on fan-only operation • Input power required: 480V 36A 3PH

DRY HEATDoes NOT Add Moisture to the environment

MAKE MODEL CAPACITY CFM BTU/HOUR HEATING AREA VOLTAGE PHASE AMP RATING DIMENSIONS (LWH) WEIGHT CAT-CLASS

Campo EB1.5E 1.5 kW 125 5,100 50 sq ft 120v 1PH 13A 10.88" x 8.33" x 12.27" 13 lbs 715-0010

Dewalt DXH165 1.65 kW 135 5,630 50 sq ft 115v 1PH 13.5A 14.5" x 11" x 13.5" 14 lbs 715-0010

Phoenix FIREBIRD COMPACT 20 5-20 kW 250 20,000 300 sq ft 120v 1PH 12A-48A 13" x 12.5" x 26" 35 lbs 715-0020

Campo EB6/9E 6-9 kW 55020,500 /

30,700750 sq ft 240v 1PH 24.5A/36.5A 23.5" x 13.5" x 17" 45 lbs 715-0030

Dewalt DXH1000TS 7-10 kW 35023,884 /

34,121300 sq ft 240v 1PH 30A 25.3" x 14.6" x 17.7" 37 lbs 715-0030

Fostoria FES-1524-3E 15 kW 800 51,195 2,000 sq ft 240v 3PH 36A 23.2" x 21.4" x 39" 65 lbs 715-0040

Fostoria FES-1548-3E 15 kW 800 51,195 2,000 sq ft 480v 3PH 18A 23.2" x 21.4" x 39" 65 lbs 715-0045

Campo EB18E 18 kW 1200 65,000 1,500 sq ft 208/240v 1PH - 3PH 1PH 86A/3PH 50A 35.5" x 17.5" x 20" 120 lbs 715-0046

Dewalt DXH2003TS 20 kW 60068,242 /

44,3571,200 sq ft 240v 3PH 28A / 42A 29.5" x 16.5" x 21" 35 lbs 715-0050

Fostoria FES-3048-3A 30 kW 1,100 102,390 2,000 sq ft 480v 3PH 36A 23.3" x 22" x 39" 83 lbs 715-0060

Campo EB60E 60 kW 4,500205,000 /

136,5005,000 sq ft 240/480v 3PH 144A/240v 72A/480v 51.5" x 22" x 35.5" 300 lbs 715-0070

Campo EB150E480V 150 kW 14,500 512,000 15,000 sq ft 480v 3PH 87/138/196A/480v 68" x 31.5" x 56" 950 lbs 715-0245

Page 5: Direct Fired, Electric, Indirect Fired, Radiant ...

HEA

TIN

G

Call 888-777-2700 for rates and reservations24

HEATING

INDIRECT FIRED

CAMPO/EB200D

CAMPO/EB600G

• 175,000 BTU oil fired • Ductable up to 150 ft supply, 50 ft return • 40 gallon on-board fuel tank

• 575,000 BTU LP/NG fired • Ductable up to 150 ft Supply, 50 ft Return• NG/LP easy switchover valve

CAMPO/EB400D

• 396,000 BTU LP or natural gas fired • Ductable up to 150 ft supply, 50 ft return • 42 gallon on-board fuel tank

CAMPO/EB600D

• 588,000 BTU oil fired • Ductable up to 150 ft supply, 50 ft return • 42 gallon on-board fuel tank

CAMPO/BLAZE 1000G/D CAMPO/BLAZE 2000G/D

• 1,000,000 BTU LP/NG fired or oil fired • Ductable up to 400 ft • Diesel burner kit available

• 2,000,000 BTU LP/NG fired or oil fired • Ductable up to 200 ft • Diesel burner kit available

MAKE MODEL FUEL TYPE BTU/HOUR HEATING AREA CFM/SP FUEL TANK CONSUMPTION RUN TIME VOLTAGE DIMENSIONS

(LWH)WEIGHT (DRY) CAT-CLASS

Campo EB200D Diesel/K1 175,000 5,000 sq ft 3,250 / 3" 40 gal 1.25 gal/hr 32 hrs 120V 48.5” x 30.6” x 65” 250 lbs 715-0610

Flagro FVO-200RC Diesel/K1 200,000 4,700 sq ft 1,500 / 3" 23 gal 1.5 gal/hr 15 hrs 115V 53.5" x 27" x 39.5" 280 lbs 715-0610

Campo EB200G LP/NG 175,000 4,700 sq ft 3,250 / 3" External 1.9 gal LP/4.8 gal NG

depends on tank cap. 120V 48.5” x 30.6” x 65” 400 lbs 715-0615

Flagro FVNP-200RC LP/NG 200,000 4,700 sq ft 1,500 / 3" External 2.18 gal LP/200 CFH NG

depends on tank cap. 115V 51.5" x 27" x 43.5" 330 lbs 715-0615

Campo EB400D Diesel/K1 396,000 7,000 sq ft 5,500 / 3" 42 gal 2.82 gal/hr 14.9 hrs 115V 76.7” x 31” x 57.6” 550 lbs 715-0620

Flagro FVO-400RC Diesel/K1 390,000 10,000 sq ft 4,000 / 3" 42 gal 2.75 gal/hr 14 hrs 115V 70" x 29" x 54" 455 lbs 715-0620

Campo EB400G LP/NG 399,000 7,000 sq ft 5,500 / 3" External 4.46 gal LP/11.16 gal NG

depends on tank cap. 115V 76.7” x 31” x 57.6” 550 lbs 715-0630

Flagro FVNP-400RC LP/NG 390,000 10,000 sq ft 4,000 / 3" External 4.25 gal LP / 390 CFH NG

depends on tank cap. 115V 70" x 29" x 49" 470 lbs 715-0630

Campo EB600D Diesel/K1 588,000 12,000 sq ft 5,500 / 3" 42 gal 4.2 gal/hr 10 hrs 120V 76.7" x 31" x 57.6" 600 lbs 715-0631

Campo EB600G LP/NG 575,000 12,000 sq ft 5,500 / 3" External 6.39 gal LP/16.08 gal NG

depends on tank cap. 120V 76.7” x 31” x 57.6” 600 lbs 715-0632

Campo BLAZE 1000G LP/NG 1,000,000 20,000 sq ft 13,500 / 6.5" External 11.17 gal LP / 27.92 gal NG

depends on tank cap.

208/240V 1PH or 3PH 111” x 33.3” x 50” 2,000 lbs 715-0660

Campo BLAZE 2000G LP/NG 2,000,000 40,000 sq ft 16,000 / 6.5" External 22.34 gal LP / 55.84 gal NG

depends on tank cap.

208/240V 1PH or 3PH 144” x 33.3” x 67” 2,950 lbs 715-0695

Page 6: Direct Fired, Electric, Indirect Fired, Radiant ...

HercRentals.com

HEATIN

G

25

HEATING

INDUSTRIAL ELECTRIC

MAKE MODEL CAPACITY BTU CFM / SP VOLTAGE PHASE AMP RATING DIMENSIONS (LWH) WEIGHT CAT-CLASS

CAPS PHUH-ONN-150KEONN 150 kW 512,000 8,000/5 in 480V 3PH 206A 96" x 48" x 50.6" 2,500 lbs 715-0240

Campo Blaze 150E 150 kW 500,000 14,500 / 6.5 in 480V 3PH 196A 68" x 31.5" x 56" 950 lbs 715-0240

CAMPO/BLAZE 150E

• 500,000 BTU w/ 6.5" static pressure for ducting up to 200-feet • Fits through a 36" door • Input power required: 480V 87/138/196A 3PH

CAPS/150 kW

• 150 kW with (4) stages of heating capacity control• 1×20 in supply air & 1×20 in return air • 10 HP motor requires 480V 3PH 206A

MAKE MODEL HEAT OUTPUT POWER SOURCE FUEL TYPE DIMENSIONS (LWH) CAT-CLASS

Val6 KBE5L 118,000/100,000 BTU 120V Diesel/Kerosene 29.2" x 28" x 36.5" 715-0435

Val6 DayStar 51,200 BTU 120V Diesel/Kerosene 22.8" x 12.2" x 23.4" 715-0408

VAL6/KBE5L VAL6/DAYSTAR

• Radiant heat not affected by wind• Radiant heat penetrates evenly and directly onto surfaces• High and low output control

• Radiant heat not affected by wind• Radiant heat penetrates evenly and directly onto surfaces• High and low output control

RADIANT + SPECIALITY

Page 7: Direct Fired, Electric, Indirect Fired, Radiant ...

HEA

TIN

G

Call 888-777-2700 for rates and reservations26

HEATING

FLAMELESS HEATERS

WACKER/HIF 690

• 658,000 BTU output • CFM up to 3,778 • Single axle trailer, 110% fluid containment

WACKER/HIF 1200

MAC/550F MAC/750F MAC/950F

• 1,200,000 BTU output • Ductable up to 200 ft • Single axle trailer, 110% fluid containment

• 440,000 BTU output • Adjustable CFM 1,400 - 3,500 • Single axle trailer, 110% fluid containment

• 512,400 BTU output • Adjustable CFM 2,650 - 5,500 • Dual axle trailer, 110% fluid containment

• 994,000 BTU output • Adjustable CFM 3,000 - 6,000 • Dual axle trailer, 110% fluid containment

MAKE MODEL BTU CFM/SP FUEL TANK CONSUMPTION RUN TIME DIMENSIONS (LWH) WEIGHT CAT-CLASS

Wacker HIF690 457,667 3,778/5” 100 3.3 gal/hr 30 hrs 155" x 67" x 80" 3,230 lbs 715-1210

Wacker HIF1200 1,204,000 6,500/4” 206 8.6 gal/hr 23 hrs 158" x 70" x 93" 4,340 lbs 715-1240

MAC 550F 550,000 3,500/5” 125 2.6 gal/hr 40 hrs 176" x 72" x 82" 3,800 lbs 715-1210

MAC 750F 750,000 5,500/5” 165 3.55 gal/hr 46 hrs 192" x 72" x 85" 5,720 lbs 715-1220

MAC 950F 950,000 6,000/5” 165 5.4 gal/hr 30 hrs 192" x 72" x 85" 5,650 lbs 715-1230

Page 8: Direct Fired, Electric, Indirect Fired, Radiant ...

HercRentals.com

HEATIN

G

27

HEATING

SELF-CONTAINED

MAC/800G

CAMPO/EB1000CT

• 800,000 BTU Indirect oil fired • On-board generator and ducting capabilities• Mounted on a single axle trailer

• Remote On/Off and scheduler option• Alerts for unit operation failure and low fuel levels• Reduced footprint designed for the urban market• 42 hr run time• 7.5” of static pressure • 13,500 CFM = 400’ of ducting• Spill containment • 3 speed fan

WACKER/HI 770XHD

• 770,000 BTU Indirect oil fired • On-board generator and ducting capabilities• Mounted on a single axle trailer

NEW

CONTROL FROM ANY MOBILE DEVICE

MAKE MODEL TYPE BTU CFM/SP FUEL TANK CONSUMPTION RUN TIME DIMENSIONS (LWH) WEIGHT CAT-CLASS

Wacker HI 770XHD Diesel 770,000 4,000 / 4" 235 gal 5.5 gal/hr 40 hrs 187" x 94" x 88" 5,700 lbs 715-0810

MAC 800G Diesel 800,000 3,900 / 3" 175 gal 5.7 gal/hr 31 hrs 186" x 72" x 87" 4,620 lbs 715-0810

CAMPO EB1000CT Diesel 1,000,000 13,500 / 7.5" 300 gal 8.1 gal/hr 42 hrs 228" x 74.5" x 98" 5,200 lbs 715-0820

Page 9: Direct Fired, Electric, Indirect Fired, Radiant ...

HEA

TIN

G

Call 888-777-2700 for rates and reservations28

HEATING

HYDRONIC SURFACE HEATERS

THAWZALL/TCH250 FLEX-TEMP/FUSION 3000 WACKER/E3000

• 280,000 BTU gross input • Return temperature display for monitoring • 72 hours of runtime

• 280,000 BTU gross input • Up to 3,000 ft of hose • 105 hours of runtime

• 385,000 BTU gross input • Up to 3,000 ft of hose • Up to 140 hours of run time

MAKE MODEL TYPE BTU THAWING CAPACITY

CURING CAPACITY EFFICIENCY FUEL

TANKFUEL CONSUMPTION RUN TIME DIMENSIONS

(LWH) WEIGHT CAT-CLASS

THAWZALL TCH250 Diesel 234,000 6,000 sq ft 18,000 sq ft 82% 160 gal 1.75 gal/hr 72 hrs 170" x 84" x 96" 5,600 lbs 715-1010

Flex-Temp FUSION3000 Diesel 234,000 6,000 sq ft 18,000 sq ft 87% 170 gal 1.75 gal/hr 97 hrs 178.5" x 96" x 91" 8,295 lbs 715-1010

Wacker E3000 Diesel 385,000 6,000 sq ft 18,000 sq ft 83% 230 gal 2.75 gal/hr 140 hrs 181" x 91 "x 94" 7,190 lbs 715-1020

CAMPO/BLAZE CUBE 1200 CHINOOK

• 1,176,000 BTU Indirect oil fired • On-board generator and ducting capabilities • Mounted on a dual axle trailer

MAC/1.2G

• 1,200,000 BTU Indirect oil fired • On-board generator and ducting capabilities• Mounted on a dual axle trailer

MAKE MODEL TYPE BTU CFM/SP FUEL TANK CONSUMPTION RUN TIME DIMENSIONS (LWH) WEIGHT CAT-CLASS

MAC 1.2G Diesel 1,200,000 6,500 / 3" 270 gal 8.6 gal/hr 31 hrs 252" x 96" x 103" 7,000 lbs 715-0820

Campo BLAZE CUBE 1200 Diesel 1,176,000 13,000 / 3" 237 gal 8.5 gal/hr 28 hrs 203” x 102” x 99” 7,000 lbs 715-0820

SELF-CONTAINED