Development and tests of a large area CsI-TGEM-based RICH...

48
Development and tests of a large area CsI-TGEM-based RICH prototype G. Bencze 1,2 , A. Di Mauro 1 , P. Martinengo 1 , L. Mornar 1 , D. Mayani Paras 3 , E. Nappi 4 , G. Paic 1,3 , V. Peskov 1,3 1 CERN, Geneva, Switzerland 2 KFKI Research. Inst. for Part and Nucl. Phys., Hungary 3 UNAM, Mexico city, Mexico 4 INFN Bari, Bari, Italy

Transcript of Development and tests of a large area CsI-TGEM-based RICH...

Page 1: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

Development and tests of a large area CsI-TGEM-based

RICH prototype

G. Bencze1,2, A. Di Mauro1, P. Martinengo1, L. Mornar1, D. Mayani

Paras3, E. Nappi4,

G. Paic1,3, V. Peskov1,31CERN, Geneva, Switzerland

2KFKI Research. Inst. for Part and Nucl. Phys., Hungary3UNAM, Mexico city, Mexico

4INFN Bari, Bari, Italy

Page 2: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

The VHMPID should be able to identify, on a track-by-

track basis, protons enabling to study the leading particles composition in jets (correlated with the π0 and /or γ

energies deposited in the electromagnetic calorimeter).

In the framework of the ALICE upgrade program we are investigating the possibilityto build a new RICH detector allowing to extend the particle identification for hadrons up to 30GeV/c .It is called VHMPID.

(HMPID)

Page 3: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

The suggested detector will consist of a gaseous radiator (for

example, CF4

orC4

F10

) and a planar gaseous photodetector

The key element of the VHMPIDis a planar photodetectorC4

F10

Page 4: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

There are two options for planar photodetectors

which are currently under evaluation:

TGEMs/RETGEMs

MWPC (similar to one used in ALICE RICH)

C4

F10

For TGEM see :

L. Periale et al., NIM A478,2002,377, S. Chalem et al., NIM A558, 2006, 475

or

Page 5: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

The aim

of this work is to build a CsI-TGEM based RICH

prototype, perform it beam test and compare to the MWPC

approach

Page 6: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

TGEM

100mm

Thickness: 0.45 mmHole d: 0.4 mmRims: 10 μmPitch: 0.8 mmActive area: 77%

TGEM is a hole-type gaseous multiplier based on standard printed circuit boardsfeaturing a combination of mechanical drilling (by a CNC drilling machine) and etching techniques.

Page 7: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

The operation principle of the CsI

coated triple

TGEM (CsI

-TGEM)

Holes

TGEMs

have several attractive features compared to ordinary GEMs:1) ~10 times higher gains 2) robustness-

capability to withstand sparks without being destroyed3) it is a self-

supporting mechanical structure making their use convenient in large detectors

Avalanches

Page 8: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

CsI-TGEMs, have some advantages, over MWPC for example:

CsI-TGEM can operate in badly quenched gases as well as in gases in which are strong UV emitters. This allows to achieve high gains without feedback

problems. This also opens a possibility to use them in unflammable

gases or if necessary

using windowless detectors (as in PHENIX)

In some experiments, if necessary CsI-TGEMs, can operate in “handron blind mode”

with zero and even reversed electric field in the drift region which allows strongly suppress the ionization signal from charged particles (PHENIX)

Page 9: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

Design of the CsI-TGEM based RICH prototype

Page 10: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

Pad plain(each pad 8x8mm)

TGEMs

CsI

Drift mesh

333

~60

11

Electronics

Beam particles

Cherenkovlight

C6

F14 radiator

PC

Acquisition

Page 11: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

135

The top view of the RICH prototype (from the electronics side)

Feethroughts RETGEM supporting flame

Cherenkovring

TGEMs

4

3

1

2

5

6

Page 12: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

View from the back plane

Page 13: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

CsI

side

Page 14: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

Drift meshes (three independent grids)

Page 15: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

Voltage dividers

There was a possibility to independently observe analog signals from any of electrodes of any TGEM and if necessary individually optimize voltages on any TGEM

Page 16: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

Six triple TGEMs

were assembled using a glow box inside the RICH prototypes gas

chamber.

Page 17: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

Extra windows

Front view

The RICH prototype has windows in front of each triple TGEM allowing to irradiate the detectors ether with the radioactive sources such as 55Fe or 90Sr or with he UV light from a Hg lamp

Page 18: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

Laboratory tests

Page 19: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

Before the installation to the RICH detector, each TGEMwas individually tested in a separate small gas chamber.

In these tests we mainly identified the maximum achievable gains when the detectors were irradiated with the 55Fe source and with the UV light.

Page 20: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

Summary of single

TGEMs performance

Page 21: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

Det#1, Ne+10%CF4, 18/2, 06.04.11

1

100

10000

1000000

525 575 625 675

Volatge drop across the TGEM (V)

Gai

nDet#2

1

100

10000

1000000

560 580 600 620 640 660

Voltage drop across TGEM (V)

Gai

n

Det#3

1100

100001000000

580 600 620 640 660 680

Voltage drop acros TGEM (V)

Gai

n

Det#6,Ne+10%CF4

1100

100001000000

580 600 620 640 660 680

Voltage drop across TGEM

Gai

n

Typical results of gas gain measurements for triple CsI-TGEMs

Measurements were performed when the detectors were simultaneously irradiated with55Fe and UV light and 90Sr source

Gains in the range 3105-106

were achieved

Page 22: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

Stability?

See, for example:V. Peskov et al ., JINST 5 P11004, 2010

Page 23: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

We have solved

the stability problems by constantly keeping some voltages over

TGEMs

00.20.40.60.8

11.2

0 1 2 3 4 5 6

Time (days)

Gai

n (a

rb. u

nits

)

PS. The variations above correlated to the atmospheric pressure changes

Page 24: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

QE measurements before CsI-TGEM installation into the RICH prototype

The QE value is about 16% less than in the case of the best CsI-MWPC

Page 25: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

Beam test

Page 26: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

Our proximity focusing TGEM-based RICH prototype installed at CERN T10 beam test facility(mostly ~6 GeV/c

pions)

Scintillators

Scintillators

Liquid radiator

Page 27: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

Electronics side

Page 28: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

Some results

Page 29: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

Single events display

MIP

Page 30: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

Ne+10%CH4 (overlapping events, radiator thickness 10mm)

November 2010

beam test. Noise was removed offline

Page 31: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

Ne+10%CF4 (overlapping events, rad. thickness 15 mm)

May 2011

beam test. Raw data, no noise removal

Page 32: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

Main conclusion : ~1p.e. per TGEM

Some examples of data

Page 33: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

Four triple TGEMs together

After corrections on geometry and nonuniformity of the detector response the estimated mean

total number of photoelectrons per event is about 10.2

Page 34: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

How much p.e

one can expect in “ideal conditions”: full surface (without holes) and CH4

gas:Corrections: 0.9 (extraction)x0.75=0.68

10p.e/0.68~

15pe

Page 35: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

What was achieved in the past with the CsI-MWPC (radiator 15mm)?

F. Piuz et al., NIM A433,1999, 178

Page 36: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

Overall TGEM gas gain

~1,4 x105

Radiator 15mm

Page 37: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

QE scan after the beam test

Conclusion from the scan: the QE of the CsI layer on the top of TGEMs is practically

the same

as before our tests -

about 16% less than in the case of good MWPC -

so corrected on this the total number of expected p.e. will be around 16-17-close enough to the

MWPC data

‐122 ‐97

‐72

‐56

‐31 ‐6 6

31 56 72 97

122

153

‐252.93

3.13.23.33.43.5 3.4‐

3.53.3‐3.43.2‐3.33.1‐3.23‐3.1

2.9‐3

Page 38: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

Developing the simulation program

Page 39: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for
Page 40: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

Some preliminary results of the simulation

Number of reconstructed clusters per trigger (assumption QE=0.66QE in CH4

), so ~35% accuracy

Red-experimentaldata

Blue-calculations

Page 41: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

Conclusions:

For the first time Cherenkov rings were detected with CsI- TGEMs

●The mean number of detected photoelectrons is the same as expected from estimations

Thus, preliminary It looks that TGEM is an attractive option for the ALICE VHMPID: it can operate in inflammable gases with a relatively high QE, it has a fast signals and cetera

●Of course, the final choice of the photodetector for VHMPID will be based on many considerations, for example MWPC approach has its own strong advantage: it is a well proven technology

Page 42: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

Aknowledgments:

Author would like to thank J. Van Beelen, M. Van Stenis

and M. Webber for their help

throughout this work

Page 43: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

Spare

Page 44: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

• 7 modules: •total area 11 m2

The current ALICE/HMPID Detector

See A. Di Mauro talk at his Conference

The main advantages of MWPC- it is a proven technology

First Cherenkov rings candidates at 7TeV proton-proton collisions at LHC

Page 45: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

1x101 1x102 1x103 1x104 1x105 1x106 1x1071x101

1x102

1x103

1x104

1x105

1x106

Current ModeX-ray (9keV)

Ne/CH4 (90:10)1 atm

Gai

n

Counting Rate (Hz/mm2)

Triple THGEMDouble THGEMSingle THGEM

Sparks Region

1x101 1x102 1x103 1x104 1x105 1x106 1x1071x101

1x102

1x103

1x104

1x105

1x106

Current ModeX-ray (9keV)

Ne/CF4 (90:10)1 atm

Gai

n

Counting Rate (Hz/mm2)

Triple THGEMDouble THGEMSingle THGEM

Sparks Region

Rate dependance

Triple TGEM is inside this general limit!.. So at the beam test we should not expect an unlimited gain

Page 46: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

Ne+10%CH4 raw data

1

10

100

1000

10000

600 650 700 750 800

Voltage (V)

Sign

al (m

V) 27/3

18/2 9/1

Gain10E4

The gas flow at the beam test was 27/3

Measurements with 55Fe

Page 47: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

Ne+8%CH4

110

1001000

10000

580 600 620 640 660 680 700 720

18/1.69/0.8

UVsignal

Gain 2x10E5

Measurements with 55Fe

Page 48: Development and tests of a large area CsI-TGEM-based RICH ...ndip.in2p3.fr/ndip11/AGENDA/AGENDA-by-DAY/...Author would like to thank J. Van Beelen, M. Van Stenis and M. Webber for

Ne+10%CF4, raw data

1

10

100

1000

10000

580 600 620 640 660

Volatge (V)

Sign

al (m

V) 18/2

27/3

No flow dependence in the given region