Determination of vacuum pump operational efficiency

18
Determination of Determination of Vacuum Pump Vacuum Pump Operational Efficiency Operational Efficiency [email protected], March 2014 1 By: D K Singhal [email protected]

description

Vacuum pump, efficiency, operation, seal water, air flow, gauge vacuum, mmHg

Transcript of Determination of vacuum pump operational efficiency

Page 1: Determination of vacuum pump operational efficiency

Determination of Determination of Vacuum Pump Vacuum Pump

Operational EfficiencyOperational Efficiency

[email protected], March 2014

1

By:

D K Singhal

[email protected]

Page 2: Determination of vacuum pump operational efficiency

Why to CheckWhy to Check

� Is vacuum pump sufficient for our need?

� Do we need to change the vacuum pump, or relocation may be tried?

[email protected], March 2014

2

Page 3: Determination of vacuum pump operational efficiency

Existing TrendsExisting Trends

� No standard available information on efficiency determination on operational conditions.

� Standard methods use standard conditions, which generally are entirely different than the mill environment.

[email protected], March 2014

3

Page 4: Determination of vacuum pump operational efficiency

No Flow VacuumNo Flow Vacuum

� This is also called as “peak vacuum” of the pump.

� Some mills check the level of vacuum developed with inlet valves closed.

� A drop in gauge vacuum is considered a drop in vacuum pump efficiency.

[email protected], March 2014

4

pump efficiency.

� Yet, if you are operating at low vacuum levels, the result obtained by this may be misleading.

Page 5: Determination of vacuum pump operational efficiency

Wet & Dry OperationWet & Dry Operation

� Routine tests account only for dry air.

� The air is sucked in at 100% RH with some entrained water. When the pressure of the same increases in the vacuum pump, some of

[email protected], March 2014

5

same increases in the vacuum pump, some of the water vapor (moisture) condenses. So, at exhaust side, you get slightly lesser airflow.

� Also, at inlet during normal operation due to water evaporation, you get lower gauge reading.

5

Page 6: Determination of vacuum pump operational efficiency

Points to RememberPoints to Remember

� Exhaust airflow reduces with increase in vacuum.

� An old vacuum may give (almost) same airflow as rated at low vacuum levels, but at high vacuum levels, capacity reduces rapidly.

[email protected], March 2014

6

reduces rapidly.

� Seal water consumption may be high at such conditions.

Page 7: Determination of vacuum pump operational efficiency

Typical Pump DataTypical Pump Data

� Take a look at a typical data supplied by a manufacturer.

mmHg Inlet Flow Capacity Loss

0 3000 0.0

50 2990 10.0

[email protected], March 2014

77

50 2990 10.0

100 2970 30.0

200 2940 60.0

300 2900 100.0

400 2800 200.0

500 2700 300.0

600 2400 600.0

660 2040 960.0Data Supplied Calculated

Page 8: Determination of vacuum pump operational efficiency

DeDe--rating at Increased Vacuumrating at Increased Vacuum

� For normal operating ranges between 200mmHG and 500mmHg, the capacity drop can be linearly correlated with vacuum level.

300.0

350.0

[email protected], March 2014

88

y = 0.82x - 122R2 = 0.9689

0.0

50.0

100.0

150.0

200.0

250.0

300.0

0 100 200 300 400 500 600

Cap

acit

y D

rop

Vacuum Level, mmHG

Page 9: Determination of vacuum pump operational efficiency

Why does the vacuum reduce?Why does the vacuum reduce?

• The drop of capacity is mainly due to two reasons-

▫ At higher vacuum level, some part of exhaust air gets short circuited to inlet air, no matter how good is sealing. Furthermore, some part of sealing water gets evaporated due to vacuum. This process increases as the vacuum pump gets

[email protected], March 2014

9

to vacuum. This process increases as the vacuum pump gets older due to wear and tear.

▫ At higher vacuum levels, there is a lot of moisture in process air to be handled. This moisture condenses in vacuum pump, and exhaust volume is lower than expected. Due to this, dry checking of vacuum pump is generally not satisfactory to process persons.

9

Page 10: Determination of vacuum pump operational efficiency

What to Check?What to Check?

� Obtain existing performance data on vacuum pump.

� Preferably, it should be at exhaust side, and the inlet side may be calculated as under-

y = 0.82x - 122

R2 = 0.9689

0.0

50.0

100.0

150.0

200.0

250.0

300.0

350.0

0 100 200 300 400 500 600

Vacuum Level, mmHG

Cap

acit

y D

rop

[email protected], March 2014

10

� Inlet flow = (760-mmHg)*Outlet Flow / 760

� Vacuum levels can be changed by throttling the inlet valves, while the machine clothing is running in wet condition.

Page 11: Determination of vacuum pump operational efficiency

Instruments for Flow MeasurementInstruments for Flow Measurement

� As flow is to be checked at exhaust side, a conventional vane flow anemometer can be used easily.

[email protected], March 2014

11

be used easily.� A hot wire anemometer, if

used, has to be calibrated properly at operating temperature and humidity conditions.

11

Page 12: Determination of vacuum pump operational efficiency

Instruments for Flow MeasurementInstruments for Flow Measurement

� Alternatively, a Pito Tube (Pilot Tube) connected with a differential pressure gauge can be used. But, the major problem is relative

[email protected], March 2014

12

can be used. But, the major problem is relative low accuracy in case of oversized piping or in case of high vacuum, low exhaust airflow condition.

12

Page 13: Determination of vacuum pump operational efficiency

Vacuum MeasurementVacuum Measurement

� A calibrated bourdon tube vacuum gauge can be used for better accuracy.

� A glycerin filled gauge ensures reading stability

[email protected], March 2014

13

� A glycerin filled gauge ensures reading stability with no pulsations.

� Alternatively, a mercury filled manometer can be used.

13

Page 14: Determination of vacuum pump operational efficiency

Sample CalculationsSample Calculations

� In this typical case, volumetric efficiency is reducing more at higher vacuum levels.

Vacuum Exh. Flow Inlet Flow Inlet Flow Volumetric

mmHg (Measured) (Calculated) (Design) Efficiency

0 2950 2950 3000 98%

[email protected], March 2014

14

0 2950 2950 3000 98%

50 2700 2890 2990 97%

100 2370 2729 2970 92%

200 1900 2579 2940 88%

300 1500 2478 2900 85%

400 1050 2217 2800 79%

500 650 1900 2700 70%

550 250 1188 2400 49%

600 - - - -

Page 15: Determination of vacuum pump operational efficiency

Operational EfficiencyOperational Efficiency

� As we can see that the operational efficiency is reducing rapidly with increase in vacuum levels.

� For practical purposes, the efficiency at the operational levels can be considered. For example, if the pump has to be operated at 400mmHg vacuum, the efficiency would

[email protected], March 2014

15

be operated at 400mmHg vacuum, the efficiency would be 79%.

� Or, we may consider that vacuum pump is giving 79% of the rated airflow.

Page 16: Determination of vacuum pump operational efficiency

ResultsResults

� On the basis of this analysis, we may conclude something like this-

� “This vacuum can be used for low vacuum applications such as Low-Vac boxes of wire part etc. as the efficiency is better at lower vacuum levels.”

[email protected], March 2014

16

is better at lower vacuum levels.”

� “On an 400mmHg operating vacuum, the pump has been de-rated by 21%. So, if it does not serve the process requirement, it should be replaced.”

� “If it is serving the process right now, we may replace the same with a new pump of smaller capacity and save power (same 21%).”

Page 17: Determination of vacuum pump operational efficiency

Changing the Vacuum PumpChanging the Vacuum Pump

� Many mills do not want to replace vacuum pump with a new one, as the present one is OK.

� In case, there is a drop in efficiency, please do consider the cost of electricity loss due to reduction in efficiency.

� If payback period suits you, talk to the best vacuum pump

[email protected], March 2014

17

� If payback period suits you, talk to the best vacuum pump suppliers, negotiate well, but, replace the vacuum pump at the earliest.

Page 18: Determination of vacuum pump operational efficiency

Thank You.Thank You.

[email protected], March 2014

18

Thank You.Thank You.