Electrical properties of various gas mixtures for active target
detector applicationDaniel Yates
Advisor: Dr. Rogachev
![Page 2: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev](https://reader034.fdocuments.net/reader034/viewer/2022050414/5f8ac633a48d60674f1a78f8/html5/thumbnails/2.jpg)
Texas Active Target (TexAT)● New active target detector under development by Rogachev
Group● Time projection chamber (TPC) setup● Gases will be used with TexAT
○ Target of beam○ Active medium for tracking
● Will be used for detailed, precise 3-D trackreconstructions from reactions of gases and rare isotope beams
2
![Page 3: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev](https://reader034.fdocuments.net/reader034/viewer/2022050414/5f8ac633a48d60674f1a78f8/html5/thumbnails/3.jpg)
Motivation● TexAT will rely on simulations for gas properties:
○ Drift Velocity○ Gas Gain
● Verification of simulators needed to provide uncertainties in track reconstruction
● Quantifying accuracy of Garfield++ drift simulation package
3
![Page 4: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev](https://reader034.fdocuments.net/reader034/viewer/2022050414/5f8ac633a48d60674f1a78f8/html5/thumbnails/4.jpg)
Approach● Testing four potential target gases for TexAT
○ He+4%CO₂○ He+10%CO₂○ Methane○ Isobutane
● TPC with applied electric field and proportional counters● 5.4MeV alpha particles ionize gas, electrons drift and
undergo Townsend avalanche near wires● Alphas hit Si detector causing timing trigger on wires● Use timing values to determine drift velocity
4
![Page 5: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev](https://reader034.fdocuments.net/reader034/viewer/2022050414/5f8ac633a48d60674f1a78f8/html5/thumbnails/5.jpg)
Setup● Voltage applied to field cage
surrounding TPC● Mesh 3mm above wires
○ e⁻ undergo avalanche in region
● Si detector with 6-slit mask across from alpha source○ Defines alpha tracks
5
![Page 6: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev](https://reader034.fdocuments.net/reader034/viewer/2022050414/5f8ac633a48d60674f1a78f8/html5/thumbnails/6.jpg)
Data Interpretation● Apply cut around alpha
energy deposits ● Ensures only timing
signals from alphas, not from outside noise
61 Channel = .6mV
![Page 7: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev](https://reader034.fdocuments.net/reader034/viewer/2022050414/5f8ac633a48d60674f1a78f8/html5/thumbnails/7.jpg)
Data Interpretation● Fit gaussians to wire
timing, use means to determine drift time
● Drift velocity can be calculated from drift time
● Averaged drift velocity of all 5 wires
7 1 Channel = .25ns
![Page 8: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev](https://reader034.fdocuments.net/reader034/viewer/2022050414/5f8ac633a48d60674f1a78f8/html5/thumbnails/8.jpg)
Simulations● Using Garfield++¹ drift
simulation package● Drifting e⁻ in same gas,
pressure, and E-field● Drifting every .5cm up to
10cm above floor● Outputs drift velocity,
timing and position resolutions
8 [1] <http://garfieldpp.web.cern.ch/garfieldpp/>
![Page 9: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev](https://reader034.fdocuments.net/reader034/viewer/2022050414/5f8ac633a48d60674f1a78f8/html5/thumbnails/9.jpg)
Results: Helium+CO₂
● 5% systematic uncertainty shown in error bars○ mainly from uncertainty
in E-Field and pressure/temperature
● Exp/Sims:○ He+4%CO₂: 1.12○ He+10%Co₂: 1.07
● Sims slightly underestimate drift velocity
9
![Page 10: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev](https://reader034.fdocuments.net/reader034/viewer/2022050414/5f8ac633a48d60674f1a78f8/html5/thumbnails/10.jpg)
Results: Methane
● Best fit of all gases● Exp/Sims: 1.02● Deviations start to occur
at higher E/P values
10
![Page 11: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev](https://reader034.fdocuments.net/reader034/viewer/2022050414/5f8ac633a48d60674f1a78f8/html5/thumbnails/11.jpg)
Results: Isobutane
● Systematic deviation apparent in Isobutane
● Experimental data is 18% higher on average
11
![Page 12: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev](https://reader034.fdocuments.net/reader034/viewer/2022050414/5f8ac633a48d60674f1a78f8/html5/thumbnails/12.jpg)
Conclusion● Garfield underestimates drift velocities of He+CO₂ mixtures
by 7-12%● Methane had only 2% deviation between experimental and
simulation values● Isobutane exhibited a systematic deviation from simulation
data○ Requires further testing with higher pressures and
different geometry
12
![Page 13: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev](https://reader034.fdocuments.net/reader034/viewer/2022050414/5f8ac633a48d60674f1a78f8/html5/thumbnails/13.jpg)
Moving Forward● Further testing of Isobutane gas● Energy gains
○ Analyze data and run simulations● Track reconstruction of alphas and electrons
13
● Special Thanks:○ Dr. Rogachev○ Dr. Koshchiy○ Dr. Uberseder○ Rogachev Group
![Page 14: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev](https://reader034.fdocuments.net/reader034/viewer/2022050414/5f8ac633a48d60674f1a78f8/html5/thumbnails/14.jpg)
14
![Page 15: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev](https://reader034.fdocuments.net/reader034/viewer/2022050414/5f8ac633a48d60674f1a78f8/html5/thumbnails/15.jpg)
Results● Both He/CO₂ mixtures
exhibited similar drift velocities and deviations from simulations
● 5% systematic deviation in error bars
● Exp/Sims:○ He4%CO₂: 1.15○ He10%CO₂: 1.10
15
![Page 16: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev](https://reader034.fdocuments.net/reader034/viewer/2022050414/5f8ac633a48d60674f1a78f8/html5/thumbnails/16.jpg)
Results● Methane matched
best of all gases● Exp/Sims: 1.03● Some deviations at
lower pressure
16
![Page 17: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev](https://reader034.fdocuments.net/reader034/viewer/2022050414/5f8ac633a48d60674f1a78f8/html5/thumbnails/17.jpg)
Evidence for Field Distortion● Wires are consistent with
external alpha source● Deviations increase closer
to source
17
![Page 18: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev](https://reader034.fdocuments.net/reader034/viewer/2022050414/5f8ac633a48d60674f1a78f8/html5/thumbnails/18.jpg)
Evidence for Field Distortion● Individual wires are
compact● Wires spread when alpha
source is moved inside
18
![Page 19: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev](https://reader034.fdocuments.net/reader034/viewer/2022050414/5f8ac633a48d60674f1a78f8/html5/thumbnails/19.jpg)
● Surrounding pressures
● With 1.5% air in mixture
19