DBC 3 - RIGHT HAND KITCHEN
DRFT
40 PSF LIVE LOAD30 PSF LIVE LOAD20 PSF LIVE LOAD20 PSF2000 PSF100 MPH EXPOSURE B
CODE:FLOORSSLEEPING AREASROOFUNINHABITABLE ATTICASSUMED SOIL BEARINGWIND
PLAN RELEASE / REVISIONS
ENGINEERING DESIGN LOADS
REV. DATE REVISION DESCRIPTION
2012 NC RESIDENTIAL BUILDING CODE
01/14/2014 INITIAL PRELIMINARY DRAWING JDM
JDS CONSULTING & DESIGN, PLLCENGINEERING, BUILDING DESIGN, & CONSTRUCTIONCONSULTING SERVICES8600 "D" JERSEY COURTRALEIGH, NC 27617FIRM LIC. NO: P-0961;PROJECT REFERENCE: SDH140023
ENGINEERING OF RECORD
ARCH PLAN VERSION
NOTE1. ENGINEER'S SEAL APPLIES TO STRUCTURAL COMPONENTS ONLY. ENGINEER'S SEAL DOES NOT CERTIFY DIMENSIONAL ACCURACY OR ARCHITECTURAL LAYOUT INCLUDING ROOF GEOMETRY. JDS CONSULTING & DESIGN, PLLC ASSUMES NO LIABILITY FOR CHANGES MADE TO THESE PLANS BY OTHERS, OR FOR CONSTRUCTION METHODS, OR FOR ANY DEVIATION FROM THE PLANS. ENGINEER TO BE NOTIFIED PRIOR TO CONSTRUCTION IN ANY DISCREPANCIES ARE NOTED ON THE PLANS.
2. ALL CONSTRUCTION, WORKMANSHIP, MATERIAL QUALITY AND SELECTION SHALL BE IN ACCORDANCE WITH THE NORTH CAROLINA STATE BUILDING CODE - RESIDENTIAL CODE 2012 EDITION FROM THE 2009 INTERNATIONAL RESIDENTIAL CODE (IRC). DIMENSIONS SHALL GOVERN OVER SCALE AND CODE SHALL GOVERN OVER DIMENSIONS.
3. THESE PLANS ARE ISSUED FOR A CONDITIONAL ONE USE FOR THE LOT OR ADDRESS SPECIFIED ON THE TITLE BLOCK. PLANS MUST HAVE SIGNED SEAL AND BE CONSTRUCTED ON SPECIFIC LOT OR ADDRESS TO BE VALID.
STRUCTURAL PLANS FOR:
01/22/2014 INITIAL STRUCTURAL SETUP PLS01/23/2014 STRUCTURAL LAYOUT FROM I-JOISTS PLANS PLS01/28/2014 STRUCTURAL REVIEW WTS02/21/2014 GLAZING CALCULATIONS, BUILDING HEIGHTS NOTED, UPDATED FOUNDATIONS GES /WTS02/26/2014 REVISE ELEVATION FOR SLAB FOUNDATION GES
JC
ON
SU
LTIN
G
DE
SIG
NDS
CLIENT:
PROJECT:
LOCATION:
ALL DESIGNS REMAIN THEINTELLECTUAL PROPERTY OF
JDS CONSULTING & DESIGN.ANY UNAUTHORIZED USE OR
DUPLICATION IS STRICTLYPROHIBITED. JDS CONSULTING& DESIGN IS NOT LIABLE FOR
CHANGES MADE TO PLANS DUETO CONSTRUCTION METHODS
OR ANY CHANGES TO PLANSMADE IN THE FIELD BY
CONTRACTOR OR BY OTHERS.DRAWINGS ARE PROVIDED TOCLIENT FOR A CONDITIONAL
ONE TIME USE ONLY.CONDITIONAL USE IS SPECIFIED
FOR THE LOT NUMBER ORPROPERTY HEREIN.
JDS CONSULTING & DESIGN, PLLC8600 'D' JERSEY CT
RALEIGH, NC 27617919.480.1075
MATERIALS
1. 1. INTERIOR / TRIMMED FRAMING LUMBER SHALL BE #2 SPRUCE PINE FIR (SPF) WITHTHE FOLLOWING DESIGN PROPERTIES:
Fb = 875 PSI Fv = 70 PSI E = 1.4E6 PSI
2. FRAMING LUMBER EXPOSED TO WEATHER OR IN CONTACT WITH THE GROUND,CONCRETE, OR MASONRY SHALL BE PRESSURE TREATED #2 SOUTHERN YELLOWPINE (SYP) WITH THE FOLLOWING DESIGN PROPERTIES:
Fb = 975 PSI Fv = 95 PSI E = 1.6E6 PSI
3. LVL STRUCTURAL MEMBERS TO BE LAMINATED VENEER LUMBER WITH THEFOLLOWING MINIMUM DESIGN PROPERTIES:
Fb = 2600 PSI Fv = 285 PSI E = 1.9E6 PSI
4. PSL STRUCTURAL MEMBERS TO BE PARALELL STRAND LUMBER WITH THEFOLLOWING MINIMUM DESIGN PROPERTIES:
Fb = 2900 PSI Fv = 290 PSI E = 2.0E6 PSI
5. LSL STRUCTURAL MEMBERS TO BE LAMINATED STRAND LUMBER WITH THEFOLLOWING MINIMUM DESIGN PROPERTIES:
Fb = 2250 PSI Fv = 400 PSI E = 1.55E6 PSI
6. STRUCTURAL STEEL WIDE FLANGE BEAMS SHALL CONFORM TO ASTM A36. Fy = 50KSI
7. REBAR SHALL BE DEFORMED STEEL CONFORMING TO ASTM A615 GRADE 60.
8. SEE TABLE R602.3(1) FOR STRUCTURAL MEMBER FASTENING REQUIREMENTS.
9. POURED CONCRETE TO BE MINIMUM 3000 PSI AT 28 DAYS. MATERIALS USED TOPRODUCE CONCRETE SHALL COMPLY WITH THE APPLICABLE STANDARDS LISTED INACI 318 OR ASTM C 1157.
10. CONCRETE LOCATED PER TABLE R301.2(1) SHALL BE AIR ENTRAINED PER TABLER402.2.
11. MASONRY UNITS SHALL CONFORM TO ACI 530/ASCE 5/TMS 402 AND MORTAR SHALLCOMPLY WITH ASTM C 270.
CONCRETECONTINUOUSDOUBLEDIAMETERDOUBLE JOISTDOUBLE STUD POCKETEACHFLAT PLATEFOOTINGHANGERLAMINATED VENEER LUMBERMANUFACTURERNOT TO SCALEON CENTERPRESSURE TREATEDRAFTER SUPPORTSTUD COLUMNSTUD POCKETTRIPLE JOISTTYPICALUNLESS NOTED OTHERWISEEXTRA JOIST
ABBREVIATIONS
CONCCONTDBLDIAMDJDSPEAFL PTFTGHGRLVLMFTRNTSOCPTRSSCSPTJTYPUNOXJ
ENGINEER GENERAL NOTES
1. ENGINEER'S SEAL APPLIES TO STRUCTURAL COMPONENTS ONLY. ENGINEER'SSEAL DOES NOT CERTIFY DIMENSIONSAL ACCURACY OR ARCHITECTURAL LAYOUTINCLUDING ROOF GEOMETRY. JDS CONSULTING & DESIGN, PLLC ASSUMES NOLIABILITY FOR CHANGES MADE TO THESE PLANS BY OTHERS, OR FORCONSTRUCTION METHODS, OR FOR ANY DEVIATION FROM THE PLANS. ENGINEERTO BE NOTIFIED PRIOR TO CONSTRUCTION IF ANY DISCREPANCIES ARE NOTED ONTHE PLANS.
2. ALL CONSTRUCTION, WORKMANSHIP, MATERIAL QUALITY AND SELECTION SHALLBE IN ACCORDANCE WITH THE NORTH CAROLINA STATE BUILDING CODE -RESIDENTIAL CODE 2012 EDITION FROM THE 2009 INTERNATIONAL RESIDENTIALCODE (IRC). DIMENSIONS SHALL GOVERN OVER SCALE AND CODE SHALL GOVERNOVER DIMENSIONS.
3. THESE PLANS ARE ISSUED FOR A CONDITIONAL ONE TIME USE FOR THE LOT ORADDRESS SPECIFIED ON THE TITLE BLOCK. PLANS MUST HAVE SIGNED SEAL ANDBE CONSTRUCTED ON SPECIFIED LOT OR ADDRESS TO BE VALID.
CONSTRUCTION
1. IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ALL DIMENSIONS PRIOR TOCONSTRUCTION. FURTHERMORE CONTRACTOR IS ULTIMATELY RESPONSIBLE FORCONSTRUCTION MEANS, METHODS, AND SAFETY ON SITE. NOTIFY JDS CONSULTING& DESIGN, PLLC IMMEDIATELY IF DISCREPANCIES ON PLAN EXIST.
2. ALL INTERIOR AND EXTERIOR BEARING HEADERS TO BE MINIMUM (2) 2x6 #2 SPF WITH(1) JACK AND (1) KING STUD AT EACH END U.N.O.
3. ALL ENGINEERED WOOD PRODUCTS (LVL, PSL, LSL, ETC.) SHALL BE INSTALLED WITHCONNECTIONS PER MANUFACTURER SPECIFICATIONS.
4. ALL STEEL BEAMS TO BE SUPPORTED AT EACH END WITH A MIN. BEARING LENGTHOF 3 1/2" AND FULL FLANGE WIDTH. BEAMS MUST BE ATTACHED AT EACH END WITHA MINIMUM OF FOUR 16d NAILS OR TWO 1/2" x 4" LAG SCREWS U.N.O.
5. ALL BEAMS TO BE CONTINUOUSLY SUPPORTED LATERALLY AND SHALL BEAR FULLWIDTH ON THE SUPPORTING WALLS OR COLUMNS INDICATED WITH A MINIMUM OFTHREE STUDS U.N.O.
6. SOLID BLOCKING TO BE PROVIDED AT ALL POINT LOADS THROUGH FLOOR LEVELSTO THE FOUNDATION OR TO OTHER STRUCTURAL COMPONENTS.
7. ENGINEERED WOOD FLOOR SYSTEMS AND ROOF TRUSS SYSTEMS TO BE PROVIDEDFOR REVIEW AND COORDINATED WITH THE ENGINEER OF RECORD. INSTALLATIONTO BE IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. ROOF TRUSSDRAWINGS TO BE SIGNED AND SEALED BY THE MANUFACTURER AND REVIEWED BYTHE ENGINEER OF RECORD PRIOR TO CONSTRUCTION.
8. STEEL FLITCH BEAMS TO BE BOLTED TOGETHER USING (2) ROWS OF 1/2" DIAM.BOLTS (ASTM 307) WITH WASHERS PLACED UNDER THE THREADED END OF THEBOLT. BOLTS TO BE SPACED AT 24" o.c. (MAX), AND STAGGERED TOP AND BOTTOMOF BEAM (2" EDGE DISTANCE), WITH TWO BOLTS TO BE LOCATED AT 6" FROM EACHEND OF FLITCH BEAM.
9. BRICK LINTELS TO BE 3 1/2 x 3 1/2 x 1/4 STEEL ANGLE FOR UP TO 6'-0" SPAN AND 6 x 4x 5/16 STEEL ANGLE FOR SPANS GREATER THAN 6'-0" AND UP TO 10'-0" U.N.O.
10. BRICK LINTELS AT SLOPED AREAS TO BE 4 x 3 1/2 x 1/4 STEEL ANGLE WITH 16d NAILSIN 3/16" HOLES IN 4" ANGLE LEG AT 12" o.c. TO TRIPLE RAFTER. WHEN THE SLOPEEXCEEDS 4:12 A MINIMUM OF 3 x 3 x 1/4 PLATES SHALL BE WELDED AT 24" o.c. ALONGTHE STEEL ANGLE.
11. ATTACH PORCH COLUMNS TO SLAB/FDN WALL USING ABA -OR- ABE SIMPSON POSTBASES TO FIT COLUMN SIZES CALLED ON PLAN -OR- ANY OTHER COLUMNCONNECTION WITH 500# UPLIFT.
11. ATTACH PORCH COLUMNS TO UPPER PORCH BANDS USING AC -OR- BC SIMPSONPOST CAPS TO FIT COLUMN SIZES CALLED ON PLAN -OR- ANY OTHER COLUMNCONNECTION WITH 500# UPLIFT.
12. ALL METAL HANGERS, STRAPS, AND HOLD-DOWNS TO BE SIMPSON STRONG-TIE OREQUIV.
LIVE LOAD (PSF) 40 30 20 10 20 40 40 60 50 40 200
DESIGN LOADS
TABLE R301.5DWELLING UNITSSLEEPING ROOMSATTICS WITH STORAGEATTICS WITHOUT STORAGEROOF SNOWSTAIRSDECKSEXTERIOR BALCONIESPASSENGER VEHICLE GARAGESFIRE ESCAPESGUARDRAILS AND HANDRAILS
DEAD LOAD (PSF) 10 10 10 10 10 10 10 10 -- 10 --
TABLE R301.2(4) - DESIGN POSITIVE AND NEGATIVE PRESSURE FOR DOORS AND WINDOWFOR A MEAN ROOF HEIGHT OF 35 FEET OR LESS SHALL BE 25 PSF
TABLE R301.2(2) - COMPONENT AND CLADDING LOADS FOR A BUILDING LOCATED INEXPOSURE B
ROOF VALUES BOTH POSITIVE AND NEGATIVE SHALL BE DESIGNED BASED ON ROOF PITCHES AND MEAN ROOF HEIGHT AS FOLLOWS: MEAN ROOF HEIGHT ROOF PITCH 0-30 FT 35 FT 40 FT 0:12 TO 2.25:12 45.4 PSF 47.7 PSF 49.5 PSF 2.25:12 TO 7:12 34.8 PSF 36.5 PSF 37.9 PSF 7:12 TO 12:12 21.0 PSF 22.1 PSF 22.9 PSF
WALL CLADDING SHALL BE DESIGNED FOR A 24.1 PSF POSITIVE AND NEGATIVE PRESSURE
SITE WORK & FOUNDATION
1. MINIMUM ALLOWABLE SOIL BEARING CAPACITY IS ASSUMED TO BE 2000 PSF. IT ISTHE CONTRACTOR'S RESPONSIBILITY TO VERIFY SOIL BEARING CAPACITY IFUNSATISFACTORY CONDITIONS EXIST AND NOTIFY ENGINEER SO THAT THENECESSARY STRUCTURAL MODIFICATIONS CAN BE MADE.
2. CONCRETE AND MASONRY FOUNDATION WALLS TO BE SELECTED ANDCONSTRUCTED IN ACCORDANCE WITH THE PROVISIONS OF SECTION R404 OR INACCORDANCE WITH ACI 318, NCMA TR68-A, OR ACI 530/ASCE 5/TMS 402.
3. FOOTINGS, FOUNDATIONS, WALLS, AND SLABS SHALL NOT BE PLACED ON MARINECLAY, PEAT OR ANY OTHER ORGANIC MATERIAL.
4. MASONRY AND POURED CONCRETE WALL REINFORCEMENT TO BE INACCORDANCE WITH TABLES R404.1.1 (1 THROUGH 4) OF THE NORTH CAROLINARESIDENTIAL CODE.
A. PER R404.1.3, TABLES ASSUME THAT WALLS HAVEPERMANENT LATERAL SUPPORT AT THE TOP AND BOTTOM.
B. WALL REINFORCING SHALL BE PLACED ACCORDING TOFOOTNOTE (c) OF THE TABLES (REINFORCING IS NOTCENTERED IN WALL).
C. FOUNDATION DRAINS ARE ASSUMED AT ALL WALLS PERR405.
5. THE CONCRETE PROPERTIES SHALL BE AS FOLLOWS:FOR MINIMUM STRENGTH:FOOTINGS: 3000 PSI @ 28 DAYSWALLS: 3000 PSI @ 28 DAYSINTERIOR SLAB ON GRADE: 3000 PSI @ 28 DAYSGARAGE SLAB ON GRADE: 3500 PSI @ 28 DAYS (5% AIR-ENTRAINED)EXTERIOR SLAB ON GRADE: 3500 PSI @ 28 DAYS (5% AIR ENTRAINED)
6. ALL CONCRETE SLABS ON GRADE SHALL BE MINIMUM OF 4" THICK ON 6 MILPOLYETHYLENE FILM OR SEALED LAPS SYSTEM WITH 6X6 WWF AT MID SLAB.
7. FILL UNDER SLABS AND FOOTINGS SHALL BE APPROVED BACKFILL MATERIAL AT95% COMPACTION IN 6" LAYERS.
8. DO NOT BACKFILL AGAINST THE FOUNDATION WALLS UNTIL THE FIRST FLOORSUBFLOOR IS IN PLACE.
9. WHERE CONDITIONS DEVELOP REQUIRING CHANGES IN EXCAVATIONS,K SUCHCHANGES SHALL BE MADE AS DIRECTED BY THE GEO-TECHNICAL ENGINEER.
10. REINFORCING STEEL SHALL BE INTERMEDIATED GRADE NEW BILLET DEFORMEDBARS CONFORMING TO ASTM A 615. WELDED WIRE FABRIC SHALL CONFORM TOASTM A-185.
11. ALL REINFORCING BARS WHICH INTERCEPT PERPENDICULAR ELEMENTS SHALLTERMINATE IN HOOKS, PLACED TWO (2) INCHES CLEAR FROM OUTER FACE OF THEELEMENT.
12. THE CONTRACTOR SHALL NOTIFY THE BUILDING OFFICIAL OR APPROVED ENTITYAT LEAST FORTY-EIGHT (48) HOURS PRIOR TO EACH CONCRETE POUR. NOCONCRETE SHALL BE PLACED UNTIL ALL REINFORCING HAS BEEN INSTALLED BYTHE CONTRACTOR AND INSPECTED BY THE BUILDING OFFICIAL.
13. SEE FOUNDATION PLAN, DETAILS AND TYPICAL WALL SECTION FORREINFORCEMENT QUANTITIES AND SIZES.
14. WOOD SILL PLATES TO BE ANCHORED TO THE FOUNDATION WITH 1/2" ANCHORBOLTS WITH MINIMUM 7" EMBEDMENT SPACED A MAXIMUM OF 6'-0" o.c.(3'-0" FORBASEMENT WALLS) AND WITHIN 12" FROM THE ENDS OF EACH PLATE SECTION.INSTALL MIN. (2) ANCHOR BOLTS PER SECTION.
15. THE UNSUPPORTED HEIGHT OF SOLID MASONRY PIERS SHALL NOT EXCEED TENTIMES THEIR LEAST DIMENSION. UNFILLED HOLLOW PIERS MAY BE USED IF THEUNSUPPORTED HEIGHT IS NOT MORE THAN FOUR TIMES THEIR LEAST DIMENSION.
16. CENTERS OF PIERS TO BEAR IN THE MIDDLE THIRD OF THE FOOTINGS, ANDGIRDERS SHALL CENTER IN THE MIDDLE THIRD OF THE PIERS.
17. ALL FOOTINGS TO HAVE MINIMUM 2" PROJECTION ON EACH SIDE OF FOUNDATIONWALLS.
18. PROTECTIVE COVERAGE FOR REINFORCING STEEL SHALL BE AS FOLLOWS:FOOTING 3"SLAB 3/4"BEAMS & COLUMNS 2"WALLS (INT. FACE) 1"WALLS (EXT. FACE 2"WIRE MESH TO BE PLACED AT MID-DEPTH OF THE SLAB.
19. ALL FOOTING EXCAVATIONS SHALL BE INSPECTED BY THE BUILDING OFFICIALPRIOR TO THE PLACING OF ANY CONCRETE. THE BUILDING OFFICIAL SHALL BEGIVEN NOTICE FOR THE OBSERVATIONS.
20. USE BRICK PATTERN FORMS ON ALL EXPOSED CONCRETE FOUNDATION WALLS.
MISC. / SPECIAL NOTES SECTION
ROOF TRUSS SYSTEM (IF USED)TRUSS LAYOUT AND PLACEMENT BYMANUFACTURER TO COINCIDE WITHTHE SUPPORT LOCATIONS SHOWN.TRUSS PROFILES SHALL BE SEALED BYTHE TRUSS MANUFACTURER. TRUSSPLANS SHALL BE PROVIDED FORREVIEW AND COORDINATED WITH THEENGINEER OF RECORD AS REQUIREDBY THE BUILDING CODE OFFICIALS.INSTALLATION SHALL BE INACCORDANCE WITH THEMANUFACTURER'S INSTRUCTIONS.
adhered to during the construction.
General Notes and SpecificationsGeneral Notes are acknowledged and shall be
GENERAL NOTES
1. ALL WORK PERFORMED SHALL COMPLY WITH THESE GENERAL NOTES UNLESSOTHERWISE NOTED ON PLANS.
2. ALL WORK INCLUDING ALL STRUCTURAL, HVAC, ELECTRICAL AND OTHER SHALLBE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE NATIONAL, STATE ANDLOCAL CODE REGULATIONS.
3. CONTRACTOR TO VERIFY AND COORDINATE ALL THE CONDITIONS ANDDIMENSIONS AT THE SITE BEFORE BEGINNING OF CONSTRUCTION. ANYDISCREPANCIES OR OMISSIONS SHALL BE REPORTED IMMEDIATELY.
4. ALL WORK IS TO BE PERFORMED IN A PROFESSIONAL MANNER AND INACCORDANCE WITH STANDARD PRACTICE AND SHALL BE IN STRICT COMPLIANCEWITH THE MANUFACTURE'S SPECIFICATIONS AND/OR RECOMMENDATIONS.
5. ALL DIMENSIONS SHOULD BE READ OR CALCULATED AND NEVER SCALED.6. THE GENERAL AND SUB-CONTRACTORS SHALL CAREFULLY EXAMINE THE
DRAWINGS, INSPECT THE SITE AND ACQUAINT THEMSELVES WITH ALL GOVERNINGORDINANCES, LAWS, ECT. AND OTHERWISE FAMILIARIZE THEMSELVES WITH ALLMATTERS WHICH MAY AFFECT PERFORMANCE OF THE WORK.
7. ALL PRE-FAB MATERIALS, EQUIPMENT, FIXTURES AND ECT SHALL BE INSTALLEDPER MANUFACTURER INSTRUCTIONS AND REQUIREMENTS.
8. PRE-FAB FLOOR AND ROOF TRUSSES SHALL BE DESIGNED FOR LOADS REQ'D BYENGINEER
9. EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CHILDREN CAN OPEN THEDOOR FROM INSIDE.
10. EVERY BATHROOOM DOOR LOCK SHALL BE DESIGNED TO PERMIT OPENING DOORFROM THE OUTSIDE IN AN EMERGENCY. THE OPENING DEVICE SHALL BE READILYACCEPTABLE TO ANYONE OUTSIDE THE DOOR.
11. PENETRATIONS OF ANY FIRE/SMOKE BARRIER SHALL BE FILLED WITH MATERIALCAPABLE OF MAINTAINING FIRE/SMOKE RESISTANT OR PROTECTION BYAPPROVED DEVICE FOR SUCH PURPOSES AS REQUIRED.
BUILDING CODES
1. NORTH CAROLINA RESIDENTIAL CODE 2012 EDITION2. INTERNATIONAL RESIDENTIAL CODE 2009 EDITIONS3. CONSTRUCTION CLASSIFICATION TYPE: 5B
MASONRY
1. SOLID MASONRY WALLS TO HAVE "DUR-O-WALL" (OR APPROVED EQUAL)GALVANIZED TRUSS TIES AT MINIMUM 16" o.c. VERTICALLY BELOW GRADE AND 8"O.C. VERTICALLY ABOVE GRADE.
2. BRICK VENEER WALLS TO HAVE NON-CORROSIVE METAL TIES AT 16" O.C.VERTICALLY AND HORIZONTALLY.
3. PROVIDE FLASHING AT THE TOP, BOTTOM, AND SIDES OF ALL OPENING AND BASEWITH WEEP HOLES AT 24" O.C.
4. PROVIDE AT LEAST 8" OF SOLID MASONRY UNDER CONCENTRATED LOADINGCONDITIONS.
5. MORTAR TO CONFORM TO ASTM C270, TYPE N.
METALS
1. STRUCTURAL STEEL SHALL CONFORM TO THE REQUIREMENTS OF THE 9TH SECTIONOF A.I.S.C. MANUAL OF STEEL CONSTRUCTION. STRUCTURAL STEEL SHALLCONFORM TO ASTM A-36. STEEL FOR PIPE COLUMNS SHALL BE EQUIVALENTCAPACITY AND WELD ABILITY TO ASTM A-501. ALL WELDING SHALL BE INACCORDANCE TO THE AMERICAN WELDING SOCIETY CLOSE AND BE PERFORMED BYWELDERS QUALIFIED IN ACCORDANCE WITH AWS PROCEDURES. ELECTRODESSHALL CONFORM TO ASTM A-5.20 E70 SERIES.
2. STEEL COLUMNS, LINTELS, BEAMS, AND RAILINGS SHALL HAVE A SHOP COST OFRUST INHIBITING PAINT.
2.1. GUAGUE ADJUSTABEL AND FIXED STEEL COLUMNS ARE CONSTRUCTED OFCARBON STEEL WITH A MINIMUM YEILD STRENGTH OF 33KSI AND ULTIMATESTRENGTH OF 45 KSI IN ACCORDANCE WITH ASTM 500 AND MANUFACTURED BYTHE MARSHALL STAMPING COMPANY IN ACCORDANCE WITH IRC REPORT NO.88-78 AND HAVE MINIMUM 8"x4"x1/4" BEARING AND CAP PLATES UNLESS NOTEDOTHERWISE. SCREW JACK SHOULD BE ENCASED IN CONCRETE OR TACKWELDED AFTER INSTALLATION. EACH COLUMN SHOULD BE DESIGNED WITH THECAPACITY RATING AND WITHSTAND COMPRESSION LOADS AS NOTED ON PLAN.
3. ALL FASTENERS IN EXTERIOR DECKS SHALL BE GALVANIZED.4. ANCHOR BOLTS SHALL BE 1/2" DIAMETER x 16" LONG GALVANIZED (SEE DRAWING
FOR PLACEMENT AND SPACING).5. FILCH BEAMS SHALL HAVE A MINIMUM Fb = 1000 PSI, E = 1,300,000 PSI WITH 2 ROWS
1/2" BOLTS, 16" O.C. TOP AND 32" O.C. AT BOTTOM UNLESS OTHERWISE NOTED.6. JOIST HANGERS SHALL BE USED TO SUPPORT ALL PURLINS, JOISTS, AND BEAMS
NOT FRAMED OVER SUPPORTING MEMBERS.7. JOIST HANGERS SHALL BE "TECO" UNLESS OTHERWISE NOTED OR AN APPROVED
EQUAL.8. MACHINE BOLT AND CARRIAGE BOLT HOLES IN WOOD SHALL BE DRILLED 1/16"
LARGER THAN DIAMETER OF BOLT.9. LAG SCREWS SHALL BE SQUARE HEAD, OF STRUCTURAL GRADE STEEL, BE PLACED
WITH WASHERS UNDER THE HEAD.10. BOLTS IN WOOD FRAMING SHALL BE STANDARD MACHINE BOLTS WITH STANDARD
MALLEABLE IRON WASHERS OR STEEL PLATE WASHERS.11. STEEL PLATE WASHER SIZES SHALL BE AS FOLLOWS:
1/2" 2-1/4"x5/16"5/8" 2-1/4"x5/16"3/4" 2-3/8"x5/16"
LINTEL SIZES SHALL BE PER THE LINTEL SCHEDULE SHOWN ON THE BRICK LINTELDETAIL, UNLESS OTHERWISE NOTED.
WOOD
1. ALL JOINTS, AND RAFTERS SHALL BE, UNLESS OTHERWISE NOTED, SPF NO 2 ORBETTER.
2. ALL EXTERIOR LUMBER AND LUMBER IN CONTACT WITH MASONRY AND CONCRETESHALL BE PRESSURE PRESERVATIVE TREATED IN ACCORDANCE WITH AWPASTANDARDS.
3. ALL NAILING SHALL COMPLY WITH IRC CODE, AND ALL STATE AND LOCAL BUILDINGCODES.
4. BUILT-UP BEAMS OR JOISTS FORMED BY A MULTIPLE OF 3-PLY OR LESS 2XMEMBERS SHALL BE CONNECTED W/ 16d NAILS AT 8" O.C.
5. BUILD UP AT BEAMS FORMED BY 3-PLY OF LAMINATED VENEER LUMBER SHALL BEFASTENED W/ 3 ROWS 16d NAILS AT 12" O.C. ON EACH SIDE OR PERMANUFACTURER'S RECOMMENDATION.
6. BLOCK SOLID AT ALL BEARING SUPPORTS WHERE ADEQUATE LATERAL SUPPORTISN'T OTHERWISE PROFICED.
7. WHEN FRAMING END TO END JOISTS SHALL BE SECURED TOGETHER BY SIMPSONOR BETTER METAL STRAPS AS REQ'D.
8. ALL RAFTERS AND JOISTS FRAMING FROM OPPOSITE SIDES SHALL LAP AT LEASTSIX (6) INCHES AND BE SPIKED TOGETHER.
9. DO NOT ALTER SIZES OF MEMBERS NOTED WITHOUT APPROVAL.10. NO STRUCTURAL MEMBER SHALL BE OMITTED, NOTCHED, CUT, BLOCKED, OUT OR
RELOCATED WITHOUT PROPR APPROVAL.11. CUTTING OF WOOD BEAMS, JOISTS AND RAFTERS SHALL BE LIMITED TO CUTS AND
BORD HOLES NOT DEEPER THAN ONE-SIXTH (1/6) THE DEPTH OF THE MEMBER ANDSHALL NOT BE LOCATED IN THE MIDDLE ON-THIRD (1/3) OF THE SPAN. NOTCHESLOCATED CLOSER TO SUPPORTS THAN 3 TIMES THE DEPTH. HOLES BORED OR CUTINTO JOIST SHALL NOT BE CLOSER THAN TWO (2) INCHES TO THE TOP OR BOTTOMOF THE HOISTS AND THE DIAMETER OF THE HOLE SHALL NOT EXCEED ONE-THIRD(1/3) THE DEPTH OF THE JOIST.
12. WHERE JOIST DEPTH EXCEED TWELVE NOMINAL INCHES THERE SHALL BE NOT LESSTHAN ONE LINE OF BRIDGING IN EVERY EIGHT FEET OF SPAN IN FLOOR, ATTIC, ANDIN ROOF FRAMING. THE BRIDGING IN EVERY EIGHT FEE OF SPAN IN FLOOR, ATTIC,AND IN ROOF FRAMING. THE BRIDGING SHALL CONSIST OF NOT LESS THAN ONE BYTHREE INCH LUMBER DOUBLE NAILED AT EACH END OR EQUIVALENT METALBRACING OF EQUAL RIGIDITY
13. SUB-FLOOR TO BE 3/4" T&G PLYWOOD OR OSB PER THE PLANS.14. ALL PLYWOOD SHALL BE PINE OR EQUAL AND SHALL BE MANUFACTURED AND
GRADED IN ACCORDANCE WITH "PRODUCT STANDARD P-1-66" FOR SOFTPLYWOOD-CONSTRUCTION AND INDUSTRIAL.
15. EACH PLYWOOD/OSB SHEET SHALL BEAR THE "APA" GRADE TRADEMARK.16. ALL END JOINTS SHALL BE STAGGERED AND SHALL BUTT ALONG THE CENTER
LINES OF FRAMING MEMBERS.17. THE FACE GRAIN OF THE PLYWOOD SHALL BE LAID AT RIGHT ANGLES TO THE
JOISTS AND TRUSSES AND PARALLEL TO THE STUDS.18. NAILS SHALL BE PLACED 3/8" MINIMUM FROM THE EDGE OF THE SHEETS. THE
MINIMUM NAIL PENETRATION INTO FRAMING MEMBERS SHALL BE 1-1/2" FOR 8dNAILS AND 1-1/8" FOR 10d NAILS.
19. ALL FLOORS SHALL BE GLUED/SCREWED WITH #12 WOOD SCREWS AT 6" O.C. ONDIRECT EDGES AND AT 10" O.C. AT INTERMEDIATE.
GENERAL NOTES
20. ALL EXTERIOR BEARING WALLS SHALL BE 2X6 OR 2X4 (SPF #2 STUD GRADE) @ 16"O.C. UNLESS OTHERWISE NOTED.
21. ALL INTERIOR BEARING WALLS SHALL BE 2X4 (SPF #2 STUD GUIDE) SINGLE TOPPLATE @ 24" O.C. UNLESS OTHERWISE NOTED.
22. ALL INTERIOR NON-BEARING WALLS TO BE 2X4 (SPF #2 STUD GUIDE) SINGLE TOPPLATE @ 24" O.C. UNLESS OTHERWISE NOTED.
23. ALL BEARING WALLS TO BE 2X4 (SPF #2 STUD GUIDE) DOUBLE TOP PLATES, LAPPEDAT ALL CORNERS AND INTERSECTIONS AND STAGGER SPLICE 48" AND LOCATEOVER WALL STUDS.
24. ALL EXTERIOR CORNERS SHALL BE BRACED WITH 4X8 STRUCTURAL SHEATHING OFTHICKNESS TO MATCH THAT OF SHEATHING, OR WITH METAL BRACING OF EQUALRIGIDITY.
25. PROVIDE ADDITIONAL STUDS AT CONCENTRATED LOAD LOCATION TO MATCHNUMBER OF STUDS ABOVE THE EXTEND TO FOUNDATION.
26. NOTCHES OR BORED HOLES IN STUDS OF BEARING WALLS OR PARTITIONS SHALLNOT BE MORE THAN ON-THIRD THE DEPTH OF THE STUD.
27. THE FOLLOWING JACK/SUD SCHEDULE WILL BE USED UNLESS OTHERWISE NOTED:EXTERIOR BEARING WALLS (MINIMUM UNLESS NOTED:)
ROOF ONLY 1 FLOOR FLOORSUP TO 3'-0" 1J & 1S 1J & 1S 1J & 1S3'-0" TO 5'-0" 1J & 1S 2J & 1S 2J & 2S5'-0" TO 7'-0" 2J & 1S 2J & 1S 2J & 2S7'-0" TO 9'-0" 2J & 1S 2J & 1S 2J & 2S9'-0" TO 12'-0" 2J & 1S 2J & 1S 3J & 2S
INTERIOR BEARING WALLS (MINIMUM UNLESS NOTED):UP TO 3'-0" 1J & 1S 1J & 1S3'-0" TO 6'-0" 2J & 1S 2J & 2S6'-0" TO 9'-0" 2J & 1S 3J & 2S9'-0" TO 12'-0" 3J & 1S 4J & 3S
WHERE J = JACK UNDER HEADER S = STUD NAILED TO JACK ALONG SIDE HEADERALL JACKS AND STUDS ASSUMED TO BE 2X6 OR 2X4 SPF #2 STUD GRADE OR BETTERWITH MAXIMUM WALL EIGHT OF 9'-1 1/8". ALL JACKS AND STUDS TO BE CLUED ANDNAILED W/ 16d NAILS AT 8" O.C.28. FIRE STOPPING SHALL BE PROVIDED TO CUT OFF ALL CONCEALED DRAFT
OPENINGS (BOTH VERTICAL AND HORIZONTAL) IN THE FOLLOWING LOCATIONS:28.1. IN ALL STUD WALLS AND PARTITIONS INCLUDING FURRED SPACES AT FLOOR
AND CEILING LEVELS AND NOT MORE THAN 10' APART28.2. BETWEEN STAIR STRINGERS AT TIP AND BOTTOM AND BETWEEN STUDS IN LINE
WITH STAIR RUN.28.3. FIRE STOPS, WHEN OF WOOD, SHALL BE 2" NOMINAL THICKNESS & MAY BE
MADE OF GYPSUM BOARD, CEMENT, MINERAL WOOL OR OTHERNONCOMBUSTIBLE MATERIAL.
28.4. SPACES BETWEEN CHIMNEYS AND WOOD FRAMING SHALL BE FILLED WITHLOOSE NONCOMBUSTIBLE MATERIAL (2" MINIMUM THICKNESS).
29. ROOF TRUSS MANUFACTURER TO SUPPLY SHOP DRAWINGS AND ERECTIONDRAWINGS AND MUST BE SEALED BY A PROFESSIONAL ENGINEER REGISTERED INTHE GOVERNING JURISDICTION. FLOOR TRUSS MANUFACTURER TO SUPPLYCONNECTION AND BEARING DETAILS, BRIDGING, AND BRACING DETAILS WITHNOMINAL DIMENSIONS, TRUSS CONFIGURATIONS LUMBER GRADE AND SPECIES ANDMAGNITUDES OF FORCE IN ALL MEMBERS.
30. TRUSS DIAGRAMS SHOW DESIGN INTENT ONLY. TRUSS MANUFACTURER TO VERIFYALL SPANS, DIMENSIONS, PITCHES, ECT. AND SUBMIT SHOP DRAWINGS TO THEDESIGNER PRIOR TO FABRICATION.
31. WOOD ROOF TRUSSES TO BE INSTALLED BY MANUFACTURER'S INSTRUCTIONS.32. WOOD ROOF TRUSSES TO BE BRACED IN ACCORDANCE WITH IRC.33. FLOOR TRUSS MANUFACTURER TO SUPPLY SHOP DRAWINGS AND ERECTION
DRAWINGS AND MUST BE SEALED BY A PROFESSIONAL ENGINEER REGISTERED INTHE GIVERNING JURISDICTION. FLOOR TRUSS MANUFACTURER TO SUPPLYCONNECTION AND BEARING DETAILS, BRIDGING AND BRACING DETAILS WITHNOMINAL DIMENSIONS, TRUSS CONFIGURATIONS, LUMBER GRADE AND SPECIESAND MAGNITUDE OF FORCE IN ALL MEMBERS.
34. BAND BOARD: 2X4 CONTINUOUS U.N.O.35. FLOOR TRUSSES SHALL BE DESIGNED TO ACCOMMODATE HVAC DUCT LAYOUT AS
REQ'D.36. FLOOR TRUSSES SHALL BE DESIGNED TO LIMIT DEFLECTION TO L/480 LIVE LOAD OR
FOR A DEAD LOAD OF 16 PSF WHICH EVER IS GREATER EXCEPT IN ROOMSCONSISTING OF DIFFERENT LENGTHS OF WHICH THE DEFLECTION OF THESHORTEST SPAN SHALL GOVERN.
37. "I"-JOIST MANUFACTURER TO SUPPLY SHOP DRAWINGS AND ERECTION DRAWINGSAND MUST BE SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THEGOVERNING JURISDICTION, FLOOR JOIST MANUFACTURER TO SUPPLY CONNECTIONAND BEARING DETAILS, BRIDGING AND BRACING DETAILS, NOMINAL DIMENSIONSAND JOIST LAYOUT CONFIGURATIONS.
38. PROVIDE SOLID MATERIAL, 1 1/4" MIN. AT ALL BAND BOARDS, END CONDITIONS, ANDRING JOISTS AS RECOMMENDED BY THE MANUFACTURER.
39. FLOOR JOISTS SHALL BE DESIGNED TO LIMIT DEFLECTION TO L/480 LIVE LOADEXCEPT IN ROOMS CONSISTING OF DIFFERENT LENGTH SPANS OF WHICH THEDEFLECTION OF THE SHORTEST SPAN SHALL GOVERN.
40. PROVIDE 2X4 CRIPPLES AT ALL INTERIOR BEARING CONDITIONS.
THERMAL AND MOISTURE PROTECTION1. ONE COAT OF ASPHALT EMULSION SHALL BE APPLIED TO ALL BELOW GRADE
WALLS AT BASEMENT CONDITIONS. WHEN HABITABLE SPACE OCCURS BELOWGRADE PROVIDE AN ADDITIONAL 6 MIL POLYETHYLENE MOISTURE RETARDANT ONTHE EXTERIOR.
2. FIBERGLASS SHINGLES (20YR MIN) SHALL BE INSTALLED OVER 1 LAYER OF 15# OR30# ASPHALT SATURATED FELT.
3. ALL FLASHING TO BE OF THE APPROVED CORROSION-RESISTIVE TYPE AND SHALLBE PROVIDED WHEN EXTERIOR PORCHES, DECKS, OR STAIRS ATTACH TO A WALLOR FLOOR ASSEMBLY OR WOOD-FRAMED CONSTRUCTION. FLASH AND CAULKWOOD BEAMS AND OTHER PROJECTIONS THROUGH EXTERIOR WALLS OR ROOF.
4. ALL FLASHING, COUNTER FLASHING, AND COPING WHEN OF METAL SHALL BE OFNOT LESS THAN NO 26 US GAUGE APPROVED CORROSION RESISTANT METAL.
5. PROVIDE METAL FLASHING ABOVE ALL WINDOWS, DOORS, AND CAPITALS.6. PROVIDE EAVE FLASHING AND DRIP EDGE FLASHING AT THE ROOF EDGES.7. PROVIDE CONTINUOUS RIDGE AND EAVE VENTILATION WITH A TITAL NET FREE
VENTILATING AREA OF NOT LESS THAN 1 TO 150 OF THE AREA OF THE SPACE TO BEVENTILATED. PROVIDE A MINIMUM OF 1" SPACE BETWEEN THE ROOF SHEATHINGAND THE INSULATION.
8. ENCLOSE ATTIC TRUSS SPECIES AND ENCLOSED FOR RAFTERS SHALL HAVE CROSSVENTILATION FOR EACH SEPARATE SPACE WITH SCREENED VENTILATING OPENINGSPROTECTED AGAINST THE ENTRANCE OF MOISTURE AND RAIN IN ACCORDANCEWITH THE IRC.
9. INSTALL E.I.F.S IN STRICT ACCORDANCE TO THE MANUFACTURERS SPECIFICATIONSAND INSTALLATION INSTRUCTIONS. IT IS THE RESPONSIBILITY OF THE INSTALLATIONCONTRACTOR TO INSURE THAT ALL FLASHING IS IN PLACE TO PREVENT THE ENTRYOF WATER OR MOISTURE.
10. THE FOLLOWING INSULATION SCHEDULE WILL BE USED UNLESS OTHERWISE NOTED:SILL PLATE 1/2" FIBERGLASSPERIMETER R-8 CLOSED CELL EXTRUDED POLYSTYRENEFOUNDATION WALL R-11 FLAME SPREAD BATT (FULL HEIGHT)EXTERIOR WALL R-15 BATTFLOOR AND SOFFIT R-19FLAT CEILING R-38 BATT OR BLOWNCATHEDRAL CEILING R-38 BATTPROVIDE BUFFERS (INSULATION STOPS) FOR CONTINUOUS VENTILATION CHANNELS AS REQ'D
DOORS & WINDOWS
1. ALL WINDOWS SHALL HAVE INSULATING GLASS.2. SIZES INDICATED ON PLANS ARE NOMINAL ONLY. BUILDER TO CONSULT WITH
WINDOW MANUFACTURER TO DETERMINE EXACT SIZES, ROUGH OPENINGS, ECT3. EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE OPERABLE WINDOW OR
EXTERIOR DOOR APPROVED FOR EMERGENCY EGRESS OR RESCUE.4. WHERE WINDOWS ARE PROVIDED AS MEANS OF EGRESS OR RESCUE THEY SHALL
HAVE A SILL HEIGHT OF NOT MORE THAN 44" ABOVE THE FLOOR.5. ALL EGRESS OR RESCUE WINDOWS FROM SLEEPING ROOMS MUST HAVE A MINIMUM
NET CLEARN OPENING OF 5.7 SQ FT. THE MINIMUM NET CLEAR OPENING HEIGHTDIMENSION SHALL BE 22". THE MINIMUM NET CLEAR OPENING WIDTH SHALL BE 20".
6. THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FORTHE PURPOSES OF GLAZING AND SHALL BE TEMPERED GLASS:
6.1. GLAZING IN ALL DOORS6.2. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR
WHERE THE NEAREST VERTICAL EDGE IS WITHIN A 24" ARC OF THE DOOR IN ACLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60" ABOVE THEFLOOR OR WALKING SURFACE
6.3. GLAZING INDOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNA,STEAM ROOMS, BATHTUBS, AND SHOWERS. GLAZING IN ANY PART OF ABUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EDGEOF THE GLAZING IS LESS THAN 60" ABOVE THE DRAIN INLET.
6.4. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE WINDOWS THAT MEETS ALL OFTHE FOLLOWING CONDITIONS:
6.4.1. EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQ FT.6.4.2. BOTTOM EDGE LESS THAN 18" ABOVE THE FLOOR6.4.3. TOP EDGE GREATER THAN 36" ABOVE THE FLOOR6.4.4. ONE OR MORE WALKING SURFACES WITHIN 36" HORIZONTALLY OF THE
GLAZING.6.5. ALL GLAZING IN RAILINGS REGARDLESS OF AN AREA OR HEIGHT ABOVE
WALKING SURFACE INCLUDED ARE STRUCTURAL BALUSTER PANELS AND NONSTRUCTURAL IN-FILL PANELS.
6.6. EXCEPTIONS: THE FOLLOWING PRODUCTS, MATERIALS, AND USES ARE EXEMPTFROM THE ABOVE HAZARDOUS LOCATIONS:
6.6.1. OPENINGS IN DOORS THROUGH WHICH A 3" SPHERE IS UNABLE TO PASS6.6.2. LEADED GLASS PANELS6.6.3. FACETED AND DECORATIVE GLASS
FINISHES
1. ALL GYPSUM WALL BOARD SHALL BE INSTALLED AND FASTENED WITH GLUE ANDSCREW IN ACCORDANCE WITH THE PROVISIONS OF THE IRC CODE, LATEST EDITION,STATE AND LOCAL CODES.
2. ALL EDGES AND ENDS OF GYPSUM WALLBOARD SHALL OCCUR ON THE FRAMINGMEEMBERS EXCEPT THOSE EDGES WHICH ARE PERPENDICULAR TO THE FRAMINGMEMBERS. ALL EDGES OF GYPSUM WALLBOARD SHALL BE IN MODERATE CONTACTEXCEPT IN CONCEALED SPACES WHERE FIRE RESISTING CONSTRUCTION ISN'TREQUIRED.
3. PROVIDE MOISTURE RESISTANT DRYWALL AT ANY WET WALL AREA LIKE LAUNDRY,ECT.
4. PROVIDE CEMENT BOARD "DUROROCK" AT ALL TUBS AND SHOWERS WALLS &CEILING AND ALSO ANY FLOOR OR WALL AREAS WHICH WILL RECIEVED CERAMICTILES OR MARBLE.
5. THE GARAGE SHALL BE SEPARATED FROM THE LIVING SPACE BY 5/8" TYPE XGYPSUM WALL BOARD
6. ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS AND SOFFITSPROTECTED ON THE ENCLOSED SIDE WITH 1/2" DRYWALL.
7. PAINT SHALL BE APPLIED ACCORDING TO THE FOLLOWING:CEILINGS LATEX FLAT 1 COAT PRIMER & 1 FINISH COATWALLS LATEX FLAT 1 COAT PRIMER & 1 FINISH COATINTERIOR TRIM LATEX 1 COAT PRIMER & 2 FINISH COATSEXTERIOR TRIM: EXTERIOR LATEX 1 SHOP COAT PRIMER AND 2 FINISH COATS
SEMI GLOSSSPECIALTIES
1. PREFAB FIREPLACES, SELECTED BY THE OWNER, SHALL BE U.L. APPROVED AND BEINSTALLED PER THE IRC CODE, THEIR LISTING AND THE MANUFACTURESINSTRUCTIONS.
1. 1R/1S CLOSET SHELVES @ 68" AFF2. 2R/1S CLOSET SHELVES @ 42" & 84" AFF3. LOCATE DBL TOWEL BARS @ 38" AFF4. SET 18" TOWEL BARS @ 24" ABOVE VANITY.5. THE MAXIMUM RISER HEIGHT SHALL BE 8 1/4" AND A MINIMUM TREAD WIDTH OF 9"6. STAIRWAYS SHALL NOT BE LESS THAN 36" CLEAR WIDTH & HEADROOM OF NOT LESS
THAN 6'-8". THE MINIMUM WIDTH AT THE HANDRAIL SHALL NOT BE LESS THAN 32"WITH HAND RAIL ON ONE SIDE AND 28" WITH A HAND RAIL ON BOTH.
7. ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS AND SOFFITSPROTECTED ON THE ENCLOSED SIDE WITH 1/2" DRYWALL.
8. PORCHES, BALCONIES, OR RAISED FLOOR SURFACES LOCATED MORE THAN 30"ABOVE THE FLOOR IN HEIGHT.
9. OPEN SIDES OF STAIRS WITH A TOTAL RISE OF MORE THAN 30" AFF OR GRADESHALL HAVE GUARDRAILS NOT LESS THAN 34" IN HEIGHT MEASURED VERTICALLYFROM THE NOSING OF THE TREADS.
10. REQUIRED GUARDRAILS ON OPEN SIDES OF STAIRWAYS, RAISED FLOOR AREAS,BALCONIES, AND PORCHES SHALL HAVE INTERMEDIATE RAILS OR ORNAMENTALCLOSURES WHICH WILL NOT ALLOW PASSAGE OF AN OBJECT 4" IN DIAMETER.
11. EXCEPTION: THE TRIANGULAR OPENINGS FORMED BY THE RISER, TREAD ANDBOTTOM RAIL OF A GUARD AT THE OPEN SIDE OF A STAIRWAY MAY BE OF SUCH ASIZE THAT A SPHERE 6" IN DIAMETER CANNOT PASS THROUGH..
JC
ON
SU
LTIN
G
DE
SIG
NDS
CLIENT:
PROJECT:
LOCATION:
ALL DESIGNS REMAIN THEINTELLECTUAL PROPERTY OF
JDS CONSULTING & DESIGN.ANY UNAUTHORIZED USE OR
DUPLICATION IS STRICTLYPROHIBITED. JDS CONSULTING& DESIGN IS NOT LIABLE FOR
CHANGES MADE TO PLANS DUETO CONSTRUCTION METHODS
OR ANY CHANGES TO PLANSMADE IN THE FIELD BY
CONTRACTOR OR BY OTHERS.DRAWINGS ARE PROVIDED TOCLIENT FOR A CONDITIONAL
ONE TIME USE ONLY.CONDITIONAL USE IS SPECIFIED
FOR THE LOT NUMBER ORPROPERTY HEREIN.
JDS CONSULTING & DESIGN, PLLC8600 'D' JERSEY CT
RALEIGH, NC 27617919.480.1075
9'-1
"M
AIN
CLG
. HG
T.8'
-1 1
/2"
UPP
ER C
LG. H
GT.
7'-4
"W
IND
OW
HG
T6'
-8"
WIN
DO
W H
GT.
FRONT ELEVATION - ASCALE: 1/4" = 1'-0"
LEFT ELEVATION - ASCALE: 1/4" = 1'-0"
REAR ELEVATION - ASCALE: 1/4" = 1'-0"
RIGHT ELEVATION - ASCALE: 1/4" = 1'-0"
1212
1212
1212
4" CORNERBOARDS
4" WOOD TRIMTYPICAL
6" FRIEZE w/ 2"REVEAL
6" FASCIA BOARD
HORIZONTAL SIDINGTYPICAL
8x8 WOOD COL.w/ BASE & CAP.
STEPS TO GRADE
RAIL AS REQ'D
MASONRYFOUNDATION W/PARGE FINISH
412
4" CORNERBOARDS
HORIZONTAL SIDINGTYPICAL
8x8 WOOD COL.w/ BASE & CAP.
RAIL AS REQ'D
4x4 DECORATIVEPOST
8" TRIM BOARDw/ 2" CAP 6x6 POST
(SEE STRUCT)
8x8 WOOD COL.w/ BASE & CAP.
RAIL AS REQ'D
8" TRIM BOARDw/ 2" CAP
8" TRIM BOARDw/ 2" CAP
4" CORNERBOARDSTYPICAL
6x6 POST(SEE STRUCT)
8x8 WOOD COL.w/ BASE & CAP.
RAIL AS REQ'D
8" TRIM BOARDw/ 2" CAP
8" TRIM BOARDw/ 2" CAP
4" CORNERBOARDSTYPICAL
ASPHALT SHINGLES OVER 30#FELT OVER 1/2" osb OVERTRUSSES - PER ROOF PLAN
ASPHALT SHINGLES OVER 30#FELT OVER 1/2" osb OVER
TRUSSES - PER ROOF PLAN
1/6 x 3/0 LOUVERED ATTIC VENTw/ 4" WOOD SURROUND
1/6 x 3/0 LOUVERED ATTIC VENTw/ 4" WOOD SURROUND
ASPHALT SHINGLES OVER 30#FELT OVER 1/2" osb RETURN
(TYPICAL)
412
4" CORNERBOARDS
HORIZONTAL SIDINGTYPICAL
8x8 WOOD COL.w/ BASE & CAP.
RAIL AS REQ'D
MASONRYFOUNDATION W/PARGE FINISH
4x4 DECORATIVEPOST
4" CORNERBOARDS
4" WOOD TRIMTYPICAL
6" FRIEZE w/ 2"REVEAL
6" FASCIA BOARD
ASPHALT SHINGLES OVER 30#FELT OVER 1/2" osb OVERTRUSSES - PER ROOF PLAN
MASONRYFOUNDATION W/PARGE FINISH
8" TRIM BOARDw/ 2" CAP
1212
1212
ridge vent
ridge vent
ASPHALT SHINGLES OVER 30#FELT OVER 1/2" CDX OVERTRUSSES - PER ROOF PLAN
1'- 4
"
30'-1
1/2
"
GLAZING CALCULATIONS - eLEVATION A1ST FLOOR = 62 SF OF GLAZING2ND FLOOR = 50 SF OF GLAZINGGLAZING AREA TOTAL = 112 SFtotal EXTERIOR WALL AREA = 2088 SFPERCENT OF GLAZING = 5.36%
JC
ON
SU
LTIN
G
DE
SIG
NDS
CLIENT:
PROJECT:
LOCATION:
ALL DESIGNS REMAIN THEINTELLECTUAL PROPERTY OF
JDS CONSULTING & DESIGN.ANY UNAUTHORIZED USE OR
DUPLICATION IS STRICTLYPROHIBITED. JDS CONSULTING& DESIGN IS NOT LIABLE FOR
CHANGES MADE TO PLANS DUETO CONSTRUCTION METHODS
OR ANY CHANGES TO PLANSMADE IN THE FIELD BY
CONTRACTOR OR BY OTHERS.DRAWINGS ARE PROVIDED TOCLIENT FOR A CONDITIONAL
ONE TIME USE ONLY.CONDITIONAL USE IS SPECIFIED
FOR THE LOT NUMBER ORPROPERTY HEREIN.
JDS CONSULTING & DESIGN, PLLC8600 'D' JERSEY CT
RALEIGH, NC 27617919.480.1075
FIRST FLOOR PLANSCALE: 1/4" = 1'-0"
First Floor HeatedSecond Floor HeatedTotal HeatedRear deckPorch
732 Sq.Ft. 754 Sq.Ft.1486 Sq.Ft. 60 Sq.Ft. 132 Sq.Ft.
SECOND FLOOR PLAN - ASCALE: 1/4" = 1'-0"
8' CEILING
BEDRM 3
LINEN
DN
8' CEILING
BEDRM 2
8' CEILING
MASTER
WIC
CLOSETCLOSET
8' CEILING
M. BATH
8' CEILING
BATH
3/0x5/0
3/0x5/0 3/0x5/0
2/4
2/82/8
2/4
2/0
2/6 2/6
22'-0"
8'-4"8'-4"
36'-0
"
5'-4"
5'-9"10'-6"5'-9"
12'-1
1/2
"8'
-3 1
/2"
2'-1
1"12
'-8"
10'-10"11'-2"
12'-6
1/2
"
5'-6 1/2"13'-0"
8'-3 1/2" 5'-1 1/2" 8'-7"
upt=9
"
9' CEILING
FAMILY
9' CEILING
DINING9' CEILING
KITCHEN
DWSINK
RANG
ER
EFG
WASH DRY
BENCH9' CEILING
MUD RM
9' CEILING
PWDRCOV'D PR.
FRONT PORCH
3/0
12
LITE
3/0x5/0
2/8 FR 2/4
3/0x5/0
22'-0"
14'-0"8'-0"
36'-0
"6'
-0"
42'-0
"
4'-0" 4'-0" 10'-5" 3'-7"
6'-0
"28
'-6"42'-0
"
7'-6
"
5'-9"8'-10 1/4"4'-1 1/4"
3'-9"18'-3"
15'-5
"13
'-1"
12'-1
1/2
"3'
-9"
12'-4
"7'
-9 1
/2"
4'-9 1/2" 12'-0 1/2"
2/0
2/02/0 2/0
2/43'-5 1/2"
1/6
3/0x5/0
5' TUB/SHR
PREFABFIREPLACE w/FLUSH HEARTH
8x8 WOOD COL.w/ BASE & CAP.
8x8 WOOD COL.w/ BASE & CAP.
STEPS TO GRADE
RAIL AS REQ'D
DN
COATS
STAIR RAKE
3/6 C.O.
2'-7" 2'-7"
8' CEILING
MASTER
8' CEILING
M. BATH
3/0x5/0
2/4
5'-9"5'-9"
4'-6 1/2"13'-0"2/4
3'-5 1/2"
3/0x5/03/0x5/0
5'-3"5'-3"
1'-0"
3'-4
"
SECOND FLOOR PLAN - BSCALE: 1/4" = 1'-0"
5'-3
1/2
"9'
-9 1
/2"
6'-1
"
8'-0
"
45°6'-6"
1'-9 1/2"
1'-9
"
3'-8
1/2
"3'
-9 1
/2"
10'-6"10'-6"
6"
6"CLCL CL
DSP
45°
4'-6 1/2"
3'-8
"
17 r
r=7
.4"
t=9"
r=7.4"17 r
ceilingabove
1. walls drawn @ 3 1/2" widths2. set windows @ 7'-4" a.f.f. u.n.o.
1. walls drawn @ 3 1/2" widths2. set windows @ 6'-8" a.f.f. u.n.o.
3/0x5/0
3'-3 1/2"
22'-0"
2'-3
1/2
"
GLAZING CALCULATIONS - eLEVATION A1ST FLOOR = 62 SF OF GLAZING2ND FLOOR = 50 SF OF GLAZINGGLAZING AREA TOTAL = 112 SFtotal EXTERIOR WALL AREA = 2088 SFPERCENT OF GLAZINZING = 5.36%
JC
ON
SU
LTIN
G
DE
SIG
NDS
CLIENT:
PROJECT:
LOCATION:
ALL DESIGNS REMAIN THEINTELLECTUAL PROPERTY OF
JDS CONSULTING & DESIGN.ANY UNAUTHORIZED USE OR
DUPLICATION IS STRICTLYPROHIBITED. JDS CONSULTING& DESIGN IS NOT LIABLE FOR
CHANGES MADE TO PLANS DUETO CONSTRUCTION METHODS
OR ANY CHANGES TO PLANSMADE IN THE FIELD BY
CONTRACTOR OR BY OTHERS.DRAWINGS ARE PROVIDED TOCLIENT FOR A CONDITIONAL
ONE TIME USE ONLY.CONDITIONAL USE IS SPECIFIED
FOR THE LOT NUMBER ORPROPERTY HEREIN.
JDS CONSULTING & DESIGN, PLLC8600 'D' JERSEY CT
RALEIGH, NC 27617919.480.1075
CRAWL SPACE VENTILATION
THE MINIMUM NET AREA OF VENTILATION OPENINGS SHALLNOT BE LESS THAN 1 SQUARE FOOT FOR EACH 150 SQUAREFEET OF UNDERFLOOR SPACE AREA AND ONE SUCH OPENINGSHALL BE WITHIN 3 FEET OF EACH CORNER OF THE BUILDING
EXCEPTION: THE TOTAL AREA OF VENTILATION MAY BEREDUCED TO 1/1500 OF THE UNDERFLOOR AREA WHERE THEGROUND SURFACE IS TREATED WITH AN APPROVED VAPORRETARDER MATERIAL AND THE REQUIRED OPENINGS AREPLACED SO AS TO PROVIDE CROSS-VENTILATION
SQ FT OF CRAWL SPACE AREA / 150 =
SQ FT OF NET FREE AREA REQUIRED
CRAWL SPACE VENTILATION
THE MINIMUM NET AREA OF VENTILATION OPENINGS SHALLNOT BE LESS THAN 1 SQUARE FOOT FOR EACH 150 SQUAREFEET OF UNDERFLOOR SPACE AREA AND ONE SUCH OPENINGSHALL BE WITHIN 3 FEET OF EACH CORNER OF THE BUILDING
EXCEPTION: THE TOTAL AREA OF VENTILATION MAY BEREDUCED TO 1/1500 OF THE UNDERFLOOR AREA WHERE THEGROUND SURFACE IS TREATED WITH AN APPROVED VAPORRETARDER MATERIAL AND THE REQUIRED OPENINGS ARE
SQ FT OF CRAWL SPACE AREA / 150 =732
4.88 SQ FT OF NET FREE AREA REQUIRED
ROOF RAFTER SUPPORT
DOUBLE RAFTER / DOUBLE JOIST
STRUCTURAL BEAM / GIRDER
WINDOW / DOOR HEADER
POINT LOAD TRANSFER
POINT LOAD FROM ABOVE BEARING ON BEAM / GIRDER
BEAM & POINT LOAD LEGEND:
14'-0"8'-0"
22'-0"
7'-6
"28
'-6"
6'-0
"
42'-0
"
36'-0
"6'
-0"
42'-0
"
CRAWLSPACE FOUNDATION PLAN - ASCALE: 1/4" = 1'-0"
CRAWLSPACE FOUNDATION PLAN - BSCALE: 1/4" = 1'-0"
7'-0"
6'-11"8'-2"
PIERS16"x16" BRICK w/8" SOLID CAP ON30"x30"x10" CONCFOOTING(TYPICAL)
ALL GIRDERS(2) 1 3/4"x9 1/4"LVL (TYPICALU.N.O.)
11 7
/8"
I-JO
ISTS
BY
MA
NU
FAC
TUR
ER11
7/8
" I-J
OIS
TS B
Y M
AN
UFA
CTU
RER
6'-11"
STEP FOOTING
2" X 10" PT BAND SECURED TOHOUSE W/ 5
8" THRU BOLTS @ 20" O.C.
TYPICALCONC FOOTINGON 16"x16"x8"6"x6" PT POST
11'-0" 11'-0"
22'-0"
TYPICAL
TYPICAL
2x6
@ 1
6"#2
SYP
PT
4X4 P.T.POST TOHOUSE FTG.
2x8
@ 1
6" o
.c.
#2 S
YP P
T
CONC FOOTINGON 20"x20"x8"6"x6" PT POST
14'-0"8'-0"
22'-0"
7'-6
"28
'-6"
6'-0
"
42'-0
"
36'-0
"6'
-0"
42'-0
"
7'-0"7'-0"
6'-11"8'-2"
15'-6
3/4
"12
'-9 1
/2"
7'-7
3/4
"
FOUNDATION WALLS8" CMU BLOCK -or- 4"BRICK & 4" BLOCKWITH 8" SOLID CAP ON16"x8" CONTINUOUSCONCRETE FOOTING
PIERS16"x16" BRICK w/8" SOLID CAP ON30"x30"x10" CONCFOOTING(TYPICAL)
ALL GIRDERS(2) 1 3/4"x9 1/4"LVL (TYPICALU.N.O.)
MIN. 18"x24"ACCESS DOOR;32"x24" MIN. w/MECH. IN CRAWL(FIELD LOCATE)
11 7
/8"
I-JO
ISTS
BY
MA
NU
FAC
TUR
ER11
7/8
" I-J
OIS
TS B
Y M
AN
UFA
CTU
RER
6'-11"
STEP FOOTING
2" X 10" PT BAND SECURED TOHOUSE W/ 58" THRU BOLTS @ 20" O.C.
TYPICALCONC FOOTINGON 16"x16"x8"6"x6" PT POST
11'-0" 11'-0"
22'-0"
TYPICAL
TYPICAL
2x6
@ 1
6"#2
SYP
PT
4X4 P.T.POST TOHOUSE FTG.
2x8
@ 1
6" o
.c.
#2 S
YP P
T
CONC FOOTINGON 20"x20"x8"6"x6" PT POST
FOUNDATION WALLS8" CMU BLOCK -or- 4"BRICK & 4" BLOCKWITH 8" SOLID CAP ON16"x8" CONTINUOUSCONCRETE FOOTING
(3) 1
3/4
" x
11 7
/8"
LVL
7'-0"
15'-6
3/4
"12
'-9 1
/2"
7'-7
3/4
"
MIN. 18"x24"ACCESS DOOR;32"x24" MIN. w/MECH. IN CRAWL(FIELD LOCATE)
(3) 1
3/4
" x
11 7
/8"
LVL
JC
ON
SU
LTIN
G
DE
SIG
NDS
CLIENT:
PROJECT:
LOCATION:
ALL DESIGNS REMAIN THEINTELLECTUAL PROPERTY OF
JDS CONSULTING & DESIGN.ANY UNAUTHORIZED USE OR
DUPLICATION IS STRICTLYPROHIBITED. JDS CONSULTING& DESIGN IS NOT LIABLE FOR
CHANGES MADE TO PLANS DUETO CONSTRUCTION METHODS
OR ANY CHANGES TO PLANSMADE IN THE FIELD BY
CONTRACTOR OR BY OTHERS.DRAWINGS ARE PROVIDED TOCLIENT FOR A CONDITIONAL
ONE TIME USE ONLY.CONDITIONAL USE IS SPECIFIED
FOR THE LOT NUMBER ORPROPERTY HEREIN.
JDS CONSULTING & DESIGN, PLLC8600 'D' JERSEY CT
RALEIGH, NC 27617919.480.1075
FIRST FLOOR CEILING FRAMING PLAN - ASCALE: 1/4" = 1'-0"
FIRST FLOOR CEILING FRAMING PLAN - BSCALE: 1/4" = 1'-0"
2SC
3SC
2SC
4X4 P.T. POSTor EQUIV., TYP. (3) 2"x8" TYPICAL
2SC
4X4 P.T. POSTor EQUIV., TYP.
2SC(2) 2X8
(1) 1
6" L
VL F
LUSH
PORCH BEAMSTO BEAR INWALL FRAMINGTYPICAL (2) 2"x8" CONTINUOUS
16" I-JOISTS LPI-32 @ 24" O.C.
16" I-JOISTS LPI-32 @ 24" O.C.
DJ
XJ
XJ
XJ
2SC
3SC
2SC
4X4 P.T. POSTor EQUIV., TYP. (3) 2"x8" TYPICAL
2SC
4X4 P.T. POSTor EQUIV., TYP.
2SC(2) 2X8
(1) 1
6" L
VL F
LUSH
PORCH BEAMSTO BEAR INWALL FRAMINGTYPICAL (2) 2"x8" CONTINUOUS
16" I-JOISTS LPI-32 @ 24" O.C.
XJ
XJ
XJ
SJSJ
ROOF RAFTER SUPPORT
DOUBLE RAFTER / DOUBLE JOIST
STRUCTURAL BEAM / GIRDER
WINDOW / DOOR HEADER
POINT LOAD TRANSFER
POINT LOAD FROM ABOVE BEARING ON BEAM / GIRDER
BEAM & POINT LOAD LEGEND:
STRUCTURAL FRAMING NOTES
1. ALL FRAMING TO BE #2 SPF MINIMUM.
2. ALL BEARING HEADERS TO BE (2) 2"x 6"SUPPORTED W/ MIN. (1) JACK AND (1) KINGEACH END U.NO.
3. ALL NON BEARING HEADERS TO BE (2)2"x4'U.NO.
4. PROVIDE CONTINOUS BLOCKING THROUGHSTRUCTURE FOR ALL POINT LOADS.
5. ALL HANGERS AND CONNECTORS SPEC'D ARETO BE SIMPSON STRONG TIE OR EQUIVALENT.
6. ALL BEAMS SPEC'D ARE MINIMUM SIZES ONLY.LARGER MEMBERS MAY SUBSTITUTED ASNEEDED FOR EASE OF CONSTRUCTION.
7. ALL EXTERIOR WALLS TO BE FULLY SHEATHEDWITH 7/16" OSB
8. FRONT PORCH COLUMNS TO BE MIN. 4X4 PTATTACHED AT TOP AND BOTTOM USINGSIMPSON (OR EQUIV) COLUMN BASE OR SSTA24 BRACKETS. TRIM OUT PER BUILDER.
9. REAR PORCH COLUMNS TO BE MIN. 4X4 PTATTACHED AT BOTTOM USING SIMPSON (OREQUIV) ABA44 AND AT TOP USING CS 16STRAPPING (12" MIN.) TO PORCH HEADER/BAND.
10. WHEN A 4 PLY LVL IS USED ATTACH WITH (1) 1/2" Ø BOLT 12" O.C. STAGGERED TOP AND BOTTOM, 1 1/2" MIN. FROM ENDS.
16" I-JOISTS LPI-32 @ 24" O.C.
2x10FOR HEAD HIGH
16" I-JOISTS LPI-32 @ 24" O.C.
DJ
16" I-JOISTS LPI-32 @ 24" O.C.
2x10FOR HEAD HIGH
16" I-JOISTS LPI-32 @ 24" O.C.16" I-JOISTS LPI-32 @ 24" O.C.
JC
ON
SU
LTIN
G
DE
SIG
NDS
CLIENT:
PROJECT:
LOCATION:
ALL DESIGNS REMAIN THEINTELLECTUAL PROPERTY OF
JDS CONSULTING & DESIGN.ANY UNAUTHORIZED USE OR
DUPLICATION IS STRICTLYPROHIBITED. JDS CONSULTING& DESIGN IS NOT LIABLE FOR
CHANGES MADE TO PLANS DUETO CONSTRUCTION METHODS
OR ANY CHANGES TO PLANSMADE IN THE FIELD BY
CONTRACTOR OR BY OTHERS.DRAWINGS ARE PROVIDED TOCLIENT FOR A CONDITIONAL
ONE TIME USE ONLY.CONDITIONAL USE IS SPECIFIED
FOR THE LOT NUMBER ORPROPERTY HEREIN.
JDS CONSULTING & DESIGN, PLLC8600 'D' JERSEY CT
RALEIGH, NC 27617919.480.1075
MATERIALS
1. 1. INTERIOR / TRIMMED FRAMING LUMBER SHALL BE #2SPRUCE PINE FIR (SPF) WITH THE FOLLOWING DESIGNPROPERTIES:
Fb = 875 PSI Fv = 70 PSI E = 1.4E6 PSI
2. FRAMING LUMBER EXPOSED TO WEATHER OR IN CONTACTWITH THE GROUND, CONCRETE, OR MASONRY SHALL BEPRESSURE TREATED #2 SOUTHERN YELLOW PINE (SYP)WITH THE FOLLOWING DESIGN PROPERTIES:
Fb = 975 PSI Fv = 95 PSI E = 1.6E6 PSI
3. LVL STRUCTURAL MEMBERS TO BE LAMINATED VENEERLUMBER WITH THE FOLLOWING MINIMUM DESIGNPROPERTIES:
Fb = 2600 PSI Fv = 285 PSI E = 1.9E6 PSI
4. PSL STRUCTURAL MEMBERS TO BE PARALELL STRANDLUMBER WITH THE FOLLOWING MINIMUM DESIGNPROPERTIES:
Fb = 2900 PSI Fv = 290 PSI E = 2.0E6 PSI
5. LSL STRUCTURAL MEMBERS TO BE LAMINATED STRANDLUMBER WITH THE FOLLOWING MINIMUM DESIGNPROPERTIES:
Fb = 2250 PSI Fv = 400 PSI E = 1.55E6 PSI
6. STRUCTURAL STEEL WIDE FLANGE BEAMS SHALLCONFORM TO ASTM A36. Fy = 50 KSI
7. REBAR SHALL BE DEFORMED STEEL CONFORMING TOASTM A615 GRADE 60.
8. SEE TABLE R602.3(1) FOR STRUCTURAL MEMBERFASTENING REQUIREMENTS.
9. POURED CONCRETE TO BE MINIMUM 3000 PSI AT 28 DAYS.MATERIALS USED TO PRODUCE CONCRETE SHALL COMPLYWITH THE APPLICABLE STANDARDS LISTED IN ACI 318 ORASTM C 1157.
10. CONCRETE LOCATED PER TABLE R301.2(1) SHALL BE AIRENTRAINED PER TABLE R402.2.
11. MASONRY UNITS SHALL CONFORM TO ACI 530/ASCE 5/TMS402 AND MORTAR SHALL COMPLY WITH ASTM C 270.
CONCRETECONTINUOUSDOUBLEDIAMETERDOUBLE JOISTDOUBLE RAFTERDOUBLE STUD POCKETEACHEACH ENDFLAT PLATEFOOTINGHANGERJACK STUD COLUMNKING STUD COLUMNLAMINATED VENEER LUMBERMANUFACTURERNOT TO SCALEON CENTERPRESSURE TREATEDRAFTER SUPPORTSTUD COLUMNSTUD POCKETTRIPLE JOISTTRIPLE RAFTERTYPICALUNLESS NOTED OTHERWISEEXTRA JOIST
ABBREVIATIONS
CONCCONTDBLDIAMDJDRDSPEAEEFL PTFTGHGRJSKSLVLMFTRNTSOCPTRSSCSPTJTRTYPUNOXJ
GENERAL NOTES
1. ENGINEER'S SEAL APPLIES TO STRUCTURAL COMPONENTSONLY. ENGINEER'S SEAL DOES NOT CERTIFY DIMENSIONSALACCURACY OR ARCHITECTURAL LAYOUT INCLUDING ROOFGEOMETRY. JDS CONSULTING & DESIGN, PLLC ASSUMES NOLIABILITY FOR CHANGES MADE TO THESE PLANS BY OTHERS,OR FOR CONSTRUCTION METHODS, OR FOR ANY DEVIATIONFROM THE PLANS. ENGINEER TO BE NOTIFIED PRIOR TOCONSTRUCTION IF ANY DISCREPANCIES ARE NOTED ON THEPLANS.
2. ALL CONSTRUCTION, WORKMANSHIP, MATERIAL QUALITY ANDSELECTION SHALL BE IN ACCORDANCE WITH THE NORTHCAROLINA STATE BUILDING CODE - RESIDENTIAL CODE 2012EDITION FROM THE 2009 INTERNATIONAL RESIDENTIAL CODE(IRC). DIMENSIONS SHALL GOVERN OVER SCALE AND CODESHALL GOVERN OVER DIMENSIONS.
3. THESE PLANS ARE ISSUED FOR A CONDITIONAL ONE TIME USEFOR THE LOT OR ADDRESS SPECIFIED ON THE TITLE BLOCK.PLANS MUST HAVE SIGNED SEAL AND BE CONSTRUCTED ONSPECIFIED LOT OR ADDRESS TO BE VALID.
CONSTRUCTION
1. IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ALLDIMENSIONS PRIOR TO CONSTRUCTION. FURTHERMORECONTRACTOR IS ULTIMATELY RESPONSIBLE FORCONSTRUCTION MEANS, METHODS, AND SAFETY ON SITE.NOTIFY JDS CONSULTING & DESIGN, PLLC IMMEDIATELY IFDISCREPANCIES ON PLAN EXIST.
2. ALL INTERIOR AND EXTERIOR BEARING HEADERS TO BEMINIMUM (2) 2x6 #2 SPF WITH (1) JACK AND (1) KING STUD ATEACH END U.N.O.
3. ALL ENGINEERED WOOD PRODUCTS (LVL, PSL, LSL, ETC.) SHALLBE INSTALLED WITH CONNECTIONS PER MANUFACTURERSPECIFICATIONS.
4. ALL STEEL BEAMS TO BE SUPPORTED AT EACH END WITH A MIN.BEARING LENGTH OF 3 1/2" AND FULL FLANGE WIDTH. BEAMSMUST BE ATTACHED AT EACH END WITH A MINIMUM OF FOUR16d NAILS OR TWO 1/2" x 4" LAG SCREWS U.N.O.
5. ALL BEAMS TO BE CONTINUOUSLY SUPPORTED LATERALLYAND SHALL BEAR FULL WIDTH ON THE SUPPORTING WALLS ORCOLUMNS INDICATED WITH A MINIMUM OF THREE STUDS U.N.O.
6. SOLID BLOCKING TO BE PROVIDED AT ALL POINT LOADSTHROUGH FLOOR LEVELS TO THE FOUNDATION OR TO OTHERSTRUCTURAL COMPONENTS.
7. ENGINEERED WOOD FLOOR SYSTEMS AND ROOF TRUSSSYSTEMS TO BE PROVIDED FOR REVIEW AND COORDINATEDWITH THE ENGINEER OF RECORD. INSTALLATION TO BE INACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS.ROOF TRUSS DRAWINGS TO BE SIGNED AND SEALED BY THEMANUFACTURER AND REVIEWED BY THE ENGINEER OF RECORDPRIOR TO CONSTRUCTION.
8. STEEL FLITCH BEAMS TO BE BOLTED TOGETHER USING (2)ROWS OF 1/2" DIAM. BOLTS (ASTM 307) WITH WASHERS PLACEDUNDER THE THREADED END OF THE BOLT. BOLTS TO BESPACED AT 24" o.c. (MAX), AND STAGGERED TOP AND BOTTOMOF BEAM (2" EDGE DISTANCE), WITH TWO BOLTS TO BELOCATED AT 6" FROM EACH END OF FLITCH BEAM.
9. BRICK LINTELS TO BE 3 1/2 x 3 1/2 x 1/4 STEEL ANGLE FOR UP TO6'-0" SPAN AND 6 x 4 x 5/16 STEEL ANGLE FOR SPANS GREATERTHAN 6'-0" AND UP TO 10'-0" U.N.O.
10. BRICK LINTELS AT SLOPED AREAS TO BE 4 x 3 1/2 x 1/4 STEELANGLE WITH 16d NAILS IN 3/16" HOLES IN 4" ANGLE LEG AT 12"o.c. TO TRIPLE RAFTER. WHEN THE SLOPE EXCEEDS 4:12 AMINIMUM OF 3 x 3 x 1/4 PLATES SHALL BE WELDED AT 24" o.c.ALONG THE STEEL ANGLE.
11. ATTACH PORCH COLUMNS TO SLAB/FDN WALL USING ABA -OR-ABE SIMPSON POST BASES TO FIT COLUMN SIZES CALLED ONPLAN -OR- ANY OTHER COLUMN CONNECTION WITH 500# UPLIFT.
11. ATTACH PORCH COLUMNS TO UPPER PORCH BANDS USING AC-OR- BC SIMPSON POST CAPS TO FIT COLUMN SIZES CALLED ONPLAN -OR- ANY OTHER COLUMN CONNECTION WITH 500# UPLIFT.
12. ALL METAL HANGERS, STRAPS, AND HOLD-DOWNS TO BESIMPSON STRONG-TIE OR EQUIV.
LIVE LOAD (PSF) 40 30 20 10 20 40 40 60 50 40 200
DESIGN LOADS
TABLE R301.5DWELLING UNITSSLEEPING ROOMSATTICS WITH STORAGEATTICS WITHOUT STORAGEROOF SNOWSTAIRSDECKSEXTERIOR BALCONIESPASSENGER VEHICLE GARAGESFIRE ESCAPESGUARDRAILS AND HANDRAILS
TABLE R301.2(4) - DESIGN POSITIVE AND NEGATIVE PRESSURE FORDOORS AND WINDOW FOR A MEAN ROOF HEIGHT OF 35 FEET OR LESSSHALL BE 25 PSF
TABLE R301.2(2) - COMPONENT AND CLADDING LOADS FOR A BUILDINGLOCATED IN EXPOSURE B
ROOF VALUES BOTH POSITIVE AND NEGATIVE SHALL BE DESIGNED BASED ON ROOF PITCHES AND MEAN ROOF HEIGHT AS FOLLOWS: MEAN ROOF HEIGHT ROOF PITCH 0-30 FT 35 FT 40 FT 0:12 TO 2.25:12 45.4 PSF 47.7 PSF 49.5 PSF 2.25:12 TO 7:12 34.8 PSF 36.5 PSF 37.9 PSF 7:12 TO 12:12 21.0 PSF 22.1 PSF 22.9 PSF
WALL CLADDING SHALL BE DESIGNED FOR A 24.1 PSF POSITIVE AND NEGATIVE PRESSURE
FOUNDATION
1. MINIMUM ALLOWABLE SOIL BEARING CAPACITY IS ASSUMED TO BE2000 PSF. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY SOILBEARING CAPACITY IF UNSATISFACTORY CONDITIONS EXIST.
2. CONCRETE AND MASONRY FOUNDATION WALLS TO BE SELECTED ANDCONSTRUCTED IN ACCORDANCE WITH THE PROVISIONS OF SECTIONR404 OR IN ACCORDANCE WITH ACI 318, NCMA TR68-A, OR ACI530/ASCE 5/TMS 402.
3. MASONRY AND POURED CONCRETE WALL REINFORCEMENT TO BE INACCORDANCE WITH TABLES R404.1.1 (1 THROUGH 4) OF THE NORTHCAROLINA RESIDENTIAL CODE.
A. PER R404.1.3, TABLES ASSUME THAT WALLS HAVEPERMANENT LATERAL SUPPORT AT THE TOP AND BOTTOM.
B. WALL REINFORCING SHALL BE PLACED ACCORDING TOFOOTNOTE (c) OF THE TABLES (REINFORCING IS NOTCENTERED IN WALL).
C. FOUNDATION DRAINS ARE ASSUMED AT ALL WALLS PERR405.
4. WOOD SILL PLATES TO BE ANCHORED TO THE FOUNDATION WITH 1/2"ANCHOR BOLTS WITH MINIMUM 7" EMBEDMENT SPACED A MAXIMUMOF 6'-0" o.c.(3'-0" FOR BASEMENT WALLS) AND WITHIN 12" FROM THEENDS OF EACH PLATE SECTION. INSTALL MIN. (2) ANCHOR BOLTS PERSECTION.
5. THE UNSUPPORTED HEIGHT OF SOLID MASONRY PIERS SHALL NOTEXCEED TEN TIMES THEIR LEAST DIMENSION. UNFILLED HOLLOWPIERS MAY BE USED IF THE UNSUPPORTED HEIGHT IS NOT MORE THANFOUR TIMES THEIR LEAST DIMENSION.
6. CENTERS OF PIERS TO BEAR IN THE MIDDLE THIRD OF THE FOOTINGS,AND GIRDERS SHALL CENTER IN THE MIDDLE THIRD OF THE PIERS.
7. ALL FOOTINGS TO HAVE MINIMUM 2" PROJECTION ON EACH SIDE OFFOUNDATION WALLS.
ROOF TRUSS SYSTEM (IF USED)TRUSS LAYOUT AND PLACEMENT BY MANUFACTURER TO COINCIDEWITH THE SUPPORT LOCATIONS SHOWN. TRUSS PROFILES SHALL BESEALED BY THE TRUSS MANUFACTURER. TRUSS PLANS SHALL BEPROVIDED FOR REVIEW AND COORDINATED WITH THE ENGINEER OFRECORD AS REQUIRED BY THE BUILDING CODE OFFICIALS.INSTALLATION SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'SINSTRUCTIONS.
STRUCTURAL FRAMING NOTES
1. ALL FRAMING TO BE #2 SPF MINIMUM.
2. ALL BEARING HEADERS TO BE (2) 2"x 6" SUPPORTED W/MIN. (1) JACK AND (1) KING EACH END U.NO.
3. ALL NON BEARING HEADERS TO BE (2)2"x4' U.NO.
4. PROVIDE CONTINOUS BLOCKING THROUGH STRUCTURE FORALL POINT LOADS.
5. ALL HANGERS AND CONNECTORS SPEC'D ARE TO BESIMPSON STRONG TIE OR EQUIVALENT.
6. ALL BEAMS SPEC'D ARE MINIMUM SIZES ONLY. LARGERMEMBERS MAY SUBSTITUTED AS NEEDED FOR EASE OFCONSTRUCTION.
7. ALL EXTERIOR WALLS TO BE FULLY SHEATHED WITH 7/16"OSB
8. FRONT PORCH COLUMNS TO BE MIN. 4X4 PT ATTACHED ATTOP AND BOTTOM USING SIMPSON (OR EQUIV) COLUMNBASE OR SST A24 BRACKETS. TRIM OUT PER BUILDER.
9. REAR PORCH COLUMNS TO BE MIN. 4X4 PT ATTACHED ATBOTTOM USING SIMPSON (OR EQUIV) ABA44 AND AT TOPUSING CS 16 STRAPPING (12" MIN.) TO PORCH HEADER/BAND.
SPAN STEEL ANGLE SIZE
BRICK VENEER LINTEL SCHEDULE
UP TO 42" L3-1/2"x3-1/2"x1/4" 8" (MIN. @ EACH END)
UP TO 72" L6"x4"x5/16" (LLV)
L6"x4"x5/16" (LLV) ATTACH LINTEL w/ 1/2" THRUBOLT @ 12" O.C. 3" FROM EACH ENDOVER 72"
END BEARING LENGTH
8" (MIN. @ EACH END)
**REFER TO IJOIST EQUIVALENCE CHARTON I-JOIST DETAIL SHEET FORSUBSTITUTION OF MANUFACTURER SERIES
BALLOON WALL FRAMING SCHEDULE: 100 MPH
FRAMING MEMBER SIZE MAX HEIGHT (PLATE TO PLATE)2x4 @ 16" o.c. 10' - 0"2x4 @ 12" o.c. 12' - 0"
2x6 @ 16" o.c. 15' - 0"2x6 @ 12" o.c. 17' - 9"
2x8 @ 16" o.c. 19' - 0"2x8 @ 12" o.c 22' - 0"
(2) 2x4 @ 16" o.c. 14' - 6"(2) 2x4 @ 12" o.c. 17' - 0"
(2) 2x6 @ 16" o.c. 21' - 6"(2) 2x6 @ 12" o.c. 25' - 0"
(2) 2x8 @ 16" o.c. 27' - 0"(2) 2x8 @ 12" o.c 31' - 0"
**ALL HEIGHTS ARE MEASURED SUBFLOOR TO TOP OF WALL PLATE.
**WHEN SPLIT FRAMED WALLS ARE USED FOR HEIGHTS OVER 12' THECONTRACTOR SHALL ADD MIN. 6' OF CS16 COIL STRAPPING (FULLYNAILED) CENTERED OVER THE WALL BREAK.
**FINGER JOINTED MEMBERS MAY BE USED FOR CONTINUOUS HEIGHTSWHERE TRADITIONALLY MILLED LUMBER LENGTHS ARE LIMITED.
CRAWL SPACE VENTILATION
THE MINIMUM NET AREA OF VENTILATION OPENINGS SHALLNOT BE LESS THAN 1 SQUARE FOOT FOR EACH 150 SQUAREFEET OF UNDERFLOOR SPACE AREA AND ONE SUCH OPENINGSHALL BE WITHIN 3 FEET OF EACH CORNER OF THE BUILDING
EXCEPTION: THE TOTAL AREA OF VENTILATION MAY BEREDUCED TO 1/1500 OF THE UNDERFLOOR AREA WHERE THEGROUND SURFACE IS TREATED WITH AN APPROVED VAPORRETARDER MATERIAL AND THE REQUIRED OPENINGS AREPLACED SO AS TO PROVIDE CROSS-VENTILATION
SQ FT OF CRAWL SPACE AREA / 150 =XXXX
XXXX SQ FT OF NET FREE AREA REQUIRED
STRUCTURAL ROOF NOTES
1. FRAMING SHALL BE #2 SPF OR BETTERU.N.O.
2. PROVIDE 2x4 COLLAR TIES AT 48" o.c. ATUPPER
THIRD OF RAFTERS U.N.O. ON PLAN.
3. FUR RIDGES FOR FULL RAFTERCONTACT
4. PROVIDE CONTINUOUS BLOCKINGTHROUGH STRUCTURE FOR ALL POINTLOADS.
5. DENOTES OVERFRAMED AREA
6. MIN. 7/16" OSB ROOF SHEATHING
PROVIDE 2x4 RAFTER TIES AT 16" o.c. AT 45°BETWEEN RAFTERS AND CEILING JOISTS.USE (4) 16d NAILS AT EACH CONNECTION.RAFTER TIES MAY BE SPACED AT 48" o.c. ATLOCATIONS WHERE NO KNEE WALLS AREINSTALLED.
STRUCTURAL ROOF TRUSS NOTES
1. FRAMING SHALL BE #2 SPF OR BETTERU.N.O.
2. PROVIDE CONTINUOUS BLOCKINGTHROUGH STRUCTURE FOR ALL POINTLOADS.
3. DENOTES OVERFRAMED AREA
4. MIN. 7/16" OSB ROOF SHEATHING
5. TRUSS LAYOUT AND PLACEMENT BYMANUFACTURER TO COINCIDE WITH THESUPPORT LOCATIONS SHOWN. TRUSSPROFILES SHALL BE SEALED BY THETRUSS MANUFACTURER. TRUSS PLANSSHALL BE PROVIDED FOR REVIEW ANDCOORDINATED WITH THE ENGINEER OFRECORD AS REQUIRED BY THE BUILDINGCODE OFFICIALS. INSTALLATION SHALL BEIN ACCORDANCE WITH THEMANUFACTURER'S INSTRUCTIONS.
ROOF RAFTER SUPPORT
DOUBLE RAFTER / DOUBLE JOIST
STRUCTURAL BEAM / GIRDER
WINDOW / DOOR HEADER
POINT LOAD TRANSFER
POINT LOAD FROM ABOVE BEARING ON BEAM / GIRDER
BEAM & POINT LOAD LEGEND:
ROOF SYSTEM
JC
ON
SU
LTIN
G
DE
SIG
NDS
CLIENT:
PROJECT:
LOCATION:
ALL DESIGNS REMAIN THEINTELLECTUAL PROPERTY OF
JDS CONSULTING & DESIGN.ANY UNAUTHORIZED USE OR
DUPLICATION IS STRICTLYPROHIBITED. JDS CONSULTING& DESIGN IS NOT LIABLE FOR
CHANGES MADE TO PLANS DUETO CONSTRUCTION METHODS
OR ANY CHANGES TO PLANSMADE IN THE FIELD BY
CONTRACTOR OR BY OTHERS.DRAWINGS ARE PROVIDED TOCLIENT FOR A CONDITIONAL
ONE TIME USE ONLY.CONDITIONAL USE IS SPECIFIED
FOR THE LOT NUMBER ORPROPERTY HEREIN.
JDS CONSULTING & DESIGN, PLLC8600 'D' JERSEY CT
RALEIGH, NC 27617919.480.1075
SECOND FLOOR CEILING FRAMING PLAN - ASCALE: 1/4" = 1'-0"
SECOND FLOOR CEILING FRAMING PLAN - BSCALE: 1/4" = 1'-0"
RO
OF
TRU
SS B
Y M
AN
UFA
CTU
RER
(2) 2"x8"(2) 2"x8"
(2) 2"x8"(2) 2"x8"(2) 2"x8"
ROOF RAFTER SUPPORT
DOUBLE RAFTER / DOUBLE JOIST
STRUCTURAL BEAM / GIRDER
WINDOW / DOOR HEADER
POINT LOAD TRANSFER
POINT LOAD FROM ABOVE BEARING ON BEAM / GIRDER
BEAM & POINT LOAD LEGEND:
STRUCTURAL FRAMING NOTES
1. ALL FRAMING TO BE #2 SPF MINIMUM.
2. ALL BEARING HEADERS TO BE (2) 2"x 6"SUPPORTED W/ MIN. (1) JACK AND (1) KINGEACH END U.NO.
3. ALL NON BEARING HEADERS TO BE (2)2"x4'U.NO.
4. PROVIDE CONTINOUS BLOCKING THROUGHSTRUCTURE FOR ALL POINT LOADS.
5. ALL HANGERS AND CONNECTORS SPEC'D ARETO BE SIMPSON STRONG TIE OR EQUIVALENT.
6. ALL BEAMS SPEC'D ARE MINIMUM SIZES ONLY.LARGER MEMBERS MAY SUBSTITUTED ASNEEDED FOR EASE OF CONSTRUCTION.
7. ALL EXTERIOR WALLS TO BE FULLY SHEATHEDWITH 7/16" OSB
8. FRONT PORCH COLUMNS TO BE MIN. 4X4 PTATTACHED AT TOP AND BOTTOM USINGSIMPSON (OR EQUIV) COLUMN BASE OR SSTA24 BRACKETS. TRIM OUT PER BUILDER.
9. REAR PORCH COLUMNS TO BE MIN. 4X4 PTATTACHED AT BOTTOM USING SIMPSON (OREQUIV) ABA44 AND AT TOP USING CS 16STRAPPING (12" MIN.) TO PORCH HEADER/BAND.
10. WHEN A 4 PLY LVL IS USED ATTACH WITH (1) 1/2" Ø BOLT 12" O.C. STAGGERED TOP AND BOTTOM, 1 1/2" MIN. FROM ENDS.
JC
ON
SU
LTIN
G
DE
SIG
NDS
CLIENT:
PROJECT:
LOCATION:
ALL DESIGNS REMAIN THEINTELLECTUAL PROPERTY OF
JDS CONSULTING & DESIGN.ANY UNAUTHORIZED USE OR
DUPLICATION IS STRICTLYPROHIBITED. JDS CONSULTING& DESIGN IS NOT LIABLE FOR
CHANGES MADE TO PLANS DUETO CONSTRUCTION METHODS
OR ANY CHANGES TO PLANSMADE IN THE FIELD BY
CONTRACTOR OR BY OTHERS.DRAWINGS ARE PROVIDED TOCLIENT FOR A CONDITIONAL
ONE TIME USE ONLY.CONDITIONAL USE IS SPECIFIED
FOR THE LOT NUMBER ORPROPERTY HEREIN.
JDS CONSULTING & DESIGN, PLLC8600 'D' JERSEY CT
RALEIGH, NC 27617919.480.1075
13'
13'-14'
10'
10'-12'
WALL BRACE REQUIREMENTS
REQUIRED LINEAR FOOTAGE OF EXTERIOR BRACINGPANELS SHORT SIDE = _________
PROVIDED LINEAR FOOTAGE OF EXTERIOR BRACINGPANELS SHORT SIDE = _________
REQUIRED LINEAR FOOTAGE OF EXTERIOR BRACINGPANELS LONG SIDE = _________
PROVIDED LINEAR FOOTAGE OF EXTERIOR BRACINGPANELS LONG SIDE = _________
-MINIMUM PANEL WIDTH IS 24"-FIGURES BASED ON THE CONTINUOUS SHEATHING METHOD USING THE RECTANGLE CIRCUMSCRIBED AROUND THE FLOOR PLAN OR PORTION OF THE FLOOR PLAN. IF NO RECTANGLE IS NOTED THE STRUCTURE HAS BEEN FIGURED ALL WITHIN ONE RECTANGLE-PANELS MAY SHIFT UP TO 36" EITHER DIRECTION FOR EASE OF CONSTRUCTION (NAILING & BLOCK REQUIREMENTS STILL APPLY)-FOR ADDITIONAL WALL BRACING INFORMATION REFER TO WALL BRACE DETAIL SHEET DTWB (DTWB2 - HIGH WIND)
SIMPSON MSTA15 HOLD DOWN CAPACITY OF 970 POUNDS PERANCHOR WITH (12) 10d NAILS. STRAP TO BE LOCATED AT EDGE OFBRACED WALL PANEL.(CS16 STRAPPING MAY BE SUBSTITUTED w/SIMILAR LENGTH AND NAILING PATTERN)
24"WSP
SCALED LENGTHOF WALL PANELAT LOCATION
NUMERICALLENGTH OF PANEL
PANEL TYPE
48"WSP
24"WSP
48"WSP
24"WSP
24"WSP
24"WSP
FIRST FLOOR WALL BRACING PLAN - ASCALE: 1/4" = 1'-0"
FIRST FLOOR WALL BRACING PLAN - BSCALE: 1/4" = 1'-0"
48"WSP
48"WSP
48"WSP
48"WSP
48"WSP
24"WSP
48"WSP
48"WSP
48"WSP
48"WSP
24"WSP
48"WSP
48"WSP
48"WSP
48"GB
48"GB
48"WSP
48"WSP
24"WSP
48"WSP
48"WSP
48"WSP
48"WSP
24"WSP
JC
ON
SU
LTIN
G
DE
SIG
NDS
CLIENT:
PROJECT:
LOCATION:
ALL DESIGNS REMAIN THEINTELLECTUAL PROPERTY OF
JDS CONSULTING & DESIGN.ANY UNAUTHORIZED USE OR
DUPLICATION IS STRICTLYPROHIBITED. JDS CONSULTING& DESIGN IS NOT LIABLE FOR
CHANGES MADE TO PLANS DUETO CONSTRUCTION METHODS
OR ANY CHANGES TO PLANSMADE IN THE FIELD BY
CONTRACTOR OR BY OTHERS.DRAWINGS ARE PROVIDED TOCLIENT FOR A CONDITIONAL
ONE TIME USE ONLY.CONDITIONAL USE IS SPECIFIED
FOR THE LOT NUMBER ORPROPERTY HEREIN.
JDS CONSULTING & DESIGN, PLLC8600 'D' JERSEY CT
RALEIGH, NC 27617919.480.1075
9'
9'-10'
7'
7'-12'
WALL BRACE REQUIREMENTS
REQUIRED LINEAR FOOTAGE OF EXTERIOR BRACINGPANELS SHORT SIDE = _________
PROVIDED LINEAR FOOTAGE OF EXTERIOR BRACINGPANELS SHORT SIDE = _________
REQUIRED LINEAR FOOTAGE OF EXTERIOR BRACINGPANELS LONG SIDE = _________
PROVIDED LINEAR FOOTAGE OF EXTERIOR BRACINGPANELS LONG SIDE = _________
-MINIMUM PANEL WIDTH IS 24"-FIGURES BASED ON THE CONTINUOUS SHEATHING METHOD USING THE RECTANGLE CIRCUMSCRIBED AROUND THE FLOOR PLAN OR PORTION OF THE FLOOR PLAN. IF NO RECTANGLE IS NOTED THE STRUCTURE HAS BEEN FIGURED ALL WITHIN ONE RECTANGLE-PANELS MAY SHIFT UP TO 36" EITHER DIRECTION FOR EASE OF CONSTRUCTION (NAILING & BLOCK REQUIREMENTS STILL APPLY)-FOR ADDITIONAL WALL BRACING INFORMATION REFER TO WALL BRACE DETAIL SHEET DTWB (DTWB2 - HIGH WIND)
SIMPSON MSTA15 HOLD DOWN CAPACITY OF 970 POUNDS PERANCHOR WITH (12) 10d NAILS. STRAP TO BE LOCATED AT EDGE OFBRACED WALL PANEL.(CS16 STRAPPING MAY BE SUBSTITUTED w/SIMILAR LENGTH AND NAILING PATTERN)
24"WSP
SCALED LENGTHOF WALL PANELAT LOCATION
NUMERICALLENGTH OF PANEL
PANEL TYPE
SECOND FLOOR WALL BRACING PLAN - ASCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0"
48"WSP
48"WSP
48"WSP
24"WSP
48"WSP
48"WSP
48"WSP
48"WSP
48"WSP
24"WSP
48"WSP
48"WSP
48"WSP
48"WSP
48"WSP
48"WSP
48"WSP
24"WSP
48"WSP
48"WSP
48"WSP
48"WSP
48"WSP
SECOND FLOOR WALL BRACING PLAN - B
JC
ON
SU
LTIN
G
DE
SIG
NDS
CLIENT:
PROJECT:
LOCATION:
ALL DESIGNS REMAIN THEINTELLECTUAL PROPERTY OF
JDS CONSULTING & DESIGN.ANY UNAUTHORIZED USE OR
DUPLICATION IS STRICTLYPROHIBITED. JDS CONSULTING& DESIGN IS NOT LIABLE FOR
CHANGES MADE TO PLANS DUETO CONSTRUCTION METHODS
OR ANY CHANGES TO PLANSMADE IN THE FIELD BY
CONTRACTOR OR BY OTHERS.DRAWINGS ARE PROVIDED TOCLIENT FOR A CONDITIONAL
ONE TIME USE ONLY.CONDITIONAL USE IS SPECIFIED
FOR THE LOT NUMBER ORPROPERTY HEREIN.
JDS CONSULTING & DESIGN, PLLC8600 'D' JERSEY CT
RALEIGH, NC 27617919.480.1075
ATTIC VENTILATION
THE TOTAL NET FREE VENTILATING AREA SHALL NOT BELESS THAN 1 TO 150 OF THE AREA OF THE SPACEVENTILATED EXCEPT THAT THE TOTAL AREA IS PERMITTEDTO BE REDUCED TO 1 TO 300 PROVIDED AT LEAST 50% AND
IS PROVIDED BY VENTILATORS LOCATED IN THE UPPERPORTION OF THE SPACE TO BE VENTILATED AT LEAST 3'ABOVE EAVE OR CORNICE VENTS WITH THE BALANCE OFTHE REQUIRED VENTILATION PROVIDED BY EAVE ORCORNICE VENTS
SQUARE FEET OF ATTIC / 150 =924
6.16 SQUARE FEET OF NET FREE AREA REQUIRED
NOT MORE THAN 80% OF THE REQUIRED VENTILATING AREA
SCALE: 1/4" = 1'-0"ROOF PLAN - ASCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0"
ROOF PLAN - BSCALE: 1/4" = 1'-0"
RO
OF
TRU
SS B
Y M
AN
UFA
CTU
RER
ROOF RAFTER SUPPORT
DOUBLE RAFTER / DOUBLE JOIST
STRUCTURAL BEAM / GIRDER
WINDOW / DOOR HEADER
POINT LOAD TRANSFER
POINT LOAD FROM ABOVE BEARING ON BEAM / GIRDER
BEAM & POINT LOAD LEGEND:
JC
ON
SU
LTIN
G
DE
SIG
NDS
CLIENT:
PROJECT:
LOCATION:
ALL DESIGNS REMAIN THEINTELLECTUAL PROPERTY OF
JDS CONSULTING & DESIGN.ANY UNAUTHORIZED USE OR
DUPLICATION IS STRICTLYPROHIBITED. JDS CONSULTING& DESIGN IS NOT LIABLE FOR
CHANGES MADE TO PLANS DUETO CONSTRUCTION METHODS
OR ANY CHANGES TO PLANSMADE IN THE FIELD BY
CONTRACTOR OR BY OTHERS.DRAWINGS ARE PROVIDED TOCLIENT FOR A CONDITIONAL
ONE TIME USE ONLY.CONDITIONAL USE IS SPECIFIED
FOR THE LOT NUMBER ORPROPERTY HEREIN.
JDS CONSULTING & DESIGN, PLLC8600 'D' JERSEY CT
RALEIGH, NC 27617919.480.1075
3/4" = 1'-0"DROPPED PIER & GIRDER SECTION
1/2" = 1'-0"STEPPED DOWN CRAWL SECTION
3/4" = 1'-0"TYPICAL EXTERIOR WALL @ GARAGE
3/4" = 1'-0"
3/4" = 1'-0"FRONT PORCH SECTION
3/4" = 1'-0"CRAWL @ EXTERIOR WALL SECTION
2x6 P.T. SILL
VAPOR BARRIERCOVER w/6 MIL
R-19 BATT INSULATION
3/4" T.&G. O.S.B. DECKING
R-15 WALL ASSEMBLY
3/8" CDX SOFFIT
PER CODEANCHOR WALL
1"x4" FRIEZE
BRICK
NOTE:SLOPE GRADEAWAY FROM FTG.
8" CMU
4" CMU
JOISTSPER PLAN
END BAND
JOISTSPER PLAN
3/4" T.&G. O.S.B.
FILL CELLS
NOTE:SLOPE GRADEAWAY FROM FTG.
w/ MORTAR
DECKING
SEE PLAN FORGIRDER SIZE
OR PER PLAN
OR
PER
PLA
N
2x6 P.T. SILL
PIER PER PLAN
VAPOR BARRIERCOVER w/6 MIL
JOISTS PARALLEL TO WALL
2x6 P.T. SILL
VAPOR BARRIERCOVER w/6 MIL
3/4" T.&G. O.S.B. DECKING
R-15 WALL ASSEMBLY
PER CODEANCHOR WALL
NOTE:SLOPE GRADEAWAY FROM FTG.
8" CMU
4" CMU
BANDEND
JOISTSPER PLAN
BRICK2x6 P.T. SILL
VAPOR BARRIERCOVER w/6 MIL
R-15 WALL ASSEMBLY
PER CODEANCHOR WALL
NOTE:SLOPE GRADEAWAY FROM FTG.
8" CMU
4" CMU
JOISTSPER PLAN
BRICK
R-19 BATT INSULATION
3/4" T.&G. O.S.B. DECKING
@ LOW GRADE
OR PER PLAN
OR
PER
PLA
N
VAPOR BARRIERCOVER w/6 MIL
1/2" DIA. ANCHORBOLTS PER CODE
MIN
.
BRICK
JOISTSPER PLAN
R-15 WALL ASSEMBLY
R-19 BATT INSULATION
3/4" T.&G. O.S.B. DECKING
4" BRICK
2x SILL PLATE
2x WALL ASSEMBRY
FLUSH PIER & GIRDER SECTION
2x6 P.T. SILL
VAPOR BARRIERCOVER w/6 MIL
R-15 WALL ASSEMBLY
ANCHORS PER CODEBRICK WALL
NOTE:SLOPE GRADEAWAY FROM FTG.
8" CMU
JOISTSPER PLAN
BRICK
R-19 BATT INSULATION
3/4" T.&G. O.S.B. DECKING
BRICK VENEER ELEV.
FILL CELLS w/
PER CODEWALL
8" CMU
8" BRICK
MIN
.
'S' TYPE MORTAR
1/2" EXP. JOINT
4" CONC. SLAB
4" CMU
8" CMU
MIN
.
4" BRICK
NOTE:1/2" DRYWALL SEPARATIONF/CLG. & HEATED AREA WALLS.
NOTE:SLOPE GRADEAWAY FROM FTG.
WALL
ANCHORPER CODEANCHOR WALL
JOISTSPER PLAN
ASSEMBLY
3/4" T.&G. OSBDECKING
INSULATIONR-19 BATT
2x6 P.T. SILL
8" CMUSTEPS TO GRADE
4" CONC. SLAB FLASHING
#67-or- #57 STONE
BRICKROWLOCK w/ 3/4"PROJECTION
2x WALL
3/4" = 1'-0"1 CRAWL @ EXTERIOR WALL SECTION
JOISTS PERPENDICULAR TO WALL3/4" = 1'-0"2 CRAWL @ EXTERIOR WALL SECTION 3
5 6 7 8
9
4
STEP DOWN PER GRADE
JOISTSPER PLAN
3/4" T.&G. O.S.B.
FILL CELLS
NOTE:SLOPE GRADEAWAY FROM FTG.
w/ MORTAR
DECKINGINSULATIONR-19 BATT
SEE PLAN FORGIRDER SIZE
OR PER PLAN
OR
PER
PLA
N
2x6 P.T. SILL
PIER PER PLAN
VAPOR BARRIERCOVER w/6 MIL
LAP JOISTS W/ BLOCKING B/T
3/4" = 1'-0"CANTILEVER CRAWL SECTION
REINF. PER PLAN
REINF. PER PLAN
6 MIL VAPOR BAR.
6 MIL VAPOR BAR.
1/2" SHEETROCK1" AIRSPACE
HOUSE WRAP
HOUSE WRAP HOUSE WRAP
HOUSE WRAP
HOUSE WRAP 1/2" SHEETROCK
1/2" SHEETROCK
1/2" SHEETROCK1/2" SHEETROCK
R-15 WALL ASSEMBLY
END BAND
PROVIDE CONT.FLASHING ANDWEEPHOLES ATMAX. 33" O.C. ASPER R703.
END BAND
WALL TIES @24" O.C. HORIZ.AND VERT.PER R703.7
24"
MIN
.
10"
2'-6"
6'-0" MIN.
4 1/
4"
8"
PER PLAN
8"
PER PLAN
1'-6
" M
IN.
20" min.
8"
1'-6
" M
IN.
8"
16"
1'-6
" M
IN.
PER PLAN
1'-6
" M
IN.
PER PLAN
1'-6
" M
IN.
10"
2'-6"
1'-6
" M
IN.
2'-0"
PER PLAN
103/4" = 1'-0"DECK ATTACHEMENT
���"d��� GAL�� BOLTS �� �ASHER � ��" O�C��OR BRICK �ENEER STRUCTURES�
���"d��� GAL�� BOLTS �� �ASHER � ��" O�C��3� ��d GAL�� NAILS � �" O�C� AND
���" GAL�� BOLT�� �ASHER
�LOOR �OIST
BAND MATERIALTREATED BAND
AS RE��DSILL �LATE
�ANCHOR NOT SHO�N�
�LOOR �OISTTREATED
�LASHING
DECKING
3"3"
MINIMUMINSULATIONR-19 BATT
MINIMUM
7/16" OSB SHEATHING 7/16" OSB SHEATHING
7/16" OSB SHEATHING
7/16" OSB SHEATHING
7/16" OSB SHEATHING
SEE PLAN
JC
ON
SU
LTIN
G
DE
SIG
NDS
CLIENT:
PROJECT:
LOCATION:
ALL DESIGNS REMAIN THEINTELLECTUAL PROPERTY OF
JDS CONSULTING & DESIGN.ANY UNAUTHORIZED USE OR
DUPLICATION IS STRICTLYPROHIBITED. JDS CONSULTING& DESIGN IS NOT LIABLE FOR
CHANGES MADE TO PLANS DUETO CONSTRUCTION METHODS
OR ANY CHANGES TO PLANSMADE IN THE FIELD BY
CONTRACTOR OR BY OTHERS.DRAWINGS ARE PROVIDED TOCLIENT FOR A CONDITIONAL
ONE TIME USE ONLY.CONDITIONAL USE IS SPECIFIED
FOR THE LOT NUMBER ORPROPERTY HEREIN.
JDS CONSULTING & DESIGN, PLLC8600 'D' JERSEY CT
RALEIGH, NC 27617919.480.1075
SIMPSON H2.5AHOLD DOWN CAPACITYOF 535 POUNDS PERANCHOR
SIMPSON H2.5AHOLD DOWN CAPACITYOF 1070 POUNDS WITHTWO ANCHORS
PLAN VIEW
TOPPLATE
TRU
SS/R
AFT
ER
NOTES:ALL HOLD DOWN VALUES ARE BASEDON SPF LUMBER AND ARE FROMSIMPSON C-2011 CATALOG
RIM BOARD
SIMPSON MSTA15HOLD DOWN
FLOOR SHEATHINGBOTTOM PLATE
(2)STUDS @ CORNER
WALL SHEATHING
SIMPSON MSTA15 HOLD DOWN CAPACITY OF 970POUNDS PER ANCHOR WITH (12) 10d NAILS.STRAP TO BE LOCATED AT EDGE OF BRACEDWALL PANEL.
A
A2
*
SIMPSON HUS26 HANGER -UPLIFT CAPACITY OF 1550POUNDS PER ANCHOR.ALLOWABEL VERTICALLOAD 2720.
K
SIMPSON H2.5AHOLD DOWN CAPACITYOF 535 POUNDS PERANCHOR
SIMPSON H2.5AHOLD DOWN CAPACITYOF 1070 POUNDS WITHTWO ANCHORS
PLAN VIEW
TOPPLATE
TRU
SS/R
AFT
ER
NOTES:ALL HOLD DOWN VALUES ARE BASEDON SPF LUMBER AND ARE FROMSIMPSON C-2011 CATALOG
RIM BOARD
SIMPSON MSTA15HOLD DOWN
FLOOR SHEATHINGBOTTOM PLATE
(2)STUDS @ CORNER
WALL SHEATHING
SIMPSON MSTA15 HOLD DOWN CAPACITY OF 970POUNDS PER ANCHOR WITH (12) 10d NAILS.STRAP TO BE LOCATED AT EDGE OF BRACEDWALL PANEL.
A
A2
*
SIMPSON HUS26 HANGER -UPLIFT CAPACITY OF 1550POUNDS PER ANCHOR.ALLOWABEL VERTICALLOAD 2720.
K
��� BRACE ATMID �ALL HEIGHT
��� ��d NAILSAT S�LICE
��� STUDS� ��" O�C�
RA�TER
��-�" MINIMUMO�ERLA�
HURRICANE CONNECTORSIM�SON H� OR E�UAL
�RA�TERS �ER�ENDICULAR TO �OISTS�
STUD �ALL
RA�TERS S�ACE TIES � ��" OC �HEN KNEE �ALL IS NOT INSTALLED�
��� RA�TER TIE ��� DEG�� � ��" OC �� ��� ��d NAILS � EACH CONNECTION
CEILING �OISTS �C��AS S�ECI�IED
��� �LATE O�ER MINIMUM ��� C��ATTACH TO EACH C� �� ��� ��d NAILS�� �LATE SHALL BE CONTINUOUS TOBEARING SU��ORT UNLESS �LOORIS SHEATHED � ITH �L��OOD�
��" LONG �MIN� ��� �LATEATTACHED TO ��� BOTTOM �LATE��� RO�S O� ��d NAILS AT �" O�C�SEE �LAN
3/4" = 1'-0"6 RAFTER KNEE WALL TIE DOWN
RA�TERS
SEE �LAN
STUD �ALL
S�ACE RA�TER TIES AT��" O�C� �HEN KNEE �ALLIS NOT INSTALLED �UNO�
��� RA�TER TIES � ��"OC �� ��� ��d NAILS ATEACH CONNECTION
CEILING �OISTSOR LOOKOUTS
KNEE �ALLAS RE��D
3/4" = 1'-0"5 RAFTER KNEE WALL TIE DOWN
3/4" = 1'-0"1 RAFTER TOP PLATE TIE DOWN
�RA�TERS �ER�ENDICULAR TO �OISTS�
STUD �ALL
RA�TERS
��� RA�TER TIE ��� DEG�� � ��" OC �� ��� ��d NAILS � EACH CONNECTION
CEILING �OISTS �C��AS S�ECI�IED
��� �LATE O�ER MINIMUM ��� C��ATTACH TO EACH C� �� ��� ��d NAILS�� �LATE SHALL BE CONTINUOUS TOBEARING SU��ORT UNLESS �LOORIS SHEATHED � ITH �L��OOD�
��" LONG �MIN� ��� �LATEATTACHED TO ��� BOTTOM �LATE��� RO�S O� ��d NAILS AT �" O�C�
3/4" = 1'-0"3 RAFTER JOIST PLATE TIE DOWN
RA�TERS��� RA�TER TIES � ��"OC �� ��� ��d NAILS ATEACH CONNECTION
3/4" = 1'-0"2 RAFTER JOIST PLATE TIE DOWN
RA�TERS
STUD �ALL
3/4" = 1'-0"4 RAFTER VAULTED CEILING TIE DOWN
3/4" = 1'-0"7 RAFTER SPLICE - ATTIC K.W.
CEILING �OISTSLOOKOUTS
��-�" O�ERLA�AT S�LICE I�
RE�UIRED
RA�TERS
ROO� BEAM AS S�ECI�IED
ROO� SU��ORT KNEE �ALL AS RE��D
��� ��d NAILS AT S�LICE
HURRICANE CONNECTORS
3/4" = 1'-0"8 ROOF BEAM
HURRICANE CLI� �H���UNLESS OTHER� ISE NOTED�
DOUBLE TO� �LATE
RA�TERS
��� RA�TER TIES � ��"OC �� ��� ��d NAILS ATEACH CONNECTION
DBL 2 X 4 TOP PLATEDBL 2 X 4 TOP PLATE
SEE BELOW FOR TIE DOWN METHOD
STUD �ALL
DBL 2 X 4 TOP PLATEDBL 2 X 4 TOP PLATE
SEE BELOW FOR TIE DOWN METHOD
STUD �ALL
JC
ON
SU
LTIN
G
DE
SIG
NDS
CLIENT:
PROJECT:
LOCATION:
ALL DESIGNS REMAIN THEINTELLECTUAL PROPERTY OF
JDS CONSULTING & DESIGN.ANY UNAUTHORIZED USE OR
DUPLICATION IS STRICTLYPROHIBITED. JDS CONSULTING& DESIGN IS NOT LIABLE FOR
CHANGES MADE TO PLANS DUETO CONSTRUCTION METHODS
OR ANY CHANGES TO PLANSMADE IN THE FIELD BY
CONTRACTOR OR BY OTHERS.DRAWINGS ARE PROVIDED TOCLIENT FOR A CONDITIONAL
ONE TIME USE ONLY.CONDITIONAL USE IS SPECIFIED
FOR THE LOT NUMBER ORPROPERTY HEREIN.
JDS CONSULTING & DESIGN, PLLC8600 'D' JERSEY CT
RALEIGH, NC 27617919.480.1075
METHOD CS-PF: CONTINUOUS PORTAL FRAME PANEL CONSTRUCTIONNTS
2
1" = 1'-0"TYPICAL EXTERIOR CORNER FRAMING FOR CONTINUOUS SHEATHING1
4'-0"
4'-0"
4'-0"
4'-0"
** IN LIEU OF THE CORNER RETURN, A HOLD-DOWN DEVICE WITHA MINIMUM UPLIFT DESIGN VALUE OF 800# SHALL BE FASTENED TOTHE CORNER STUD AND TO THE FOUNDATION OR FRAMING BELOW.
WOOD STRUCTURAL PANELSTRENGTH AXIS
TOP PLATE CONTINUITY IS REQUIRED PER R602.3.2
FASTEN HEADER TO KING STUD WITH(6) 16d SINKER NAILS (TYP)
2'-0" TO 18'-0"
EXTENT OF HEADER
3/8" MIN THICKNESS WOODSTRUCTURAL PANEL SHEATHING
FOR 12" TO 16" WING WALL WIDTHSSHEATH INTERIOR & EXTERIOR
OR MIN. 4000# WITH PONY WALLSTRAP ON BOTH SIDES OF OPENING- INSTALLED ON BACKSIDE OF WALLFOR 12" TO 16" WING WALL WIDTHS
APPLY STRAP BOTH SIDES
MIN 3"x11.25" NET HEADERHEADER SHALL OCCUR AT TOP OF WALL
ANCHOR BOLTS PERSECTION R403.1.6
(TYP)
MIN. (2) 2x4(TYP)
FOR PANEL SPLICE (IF NEEDED),PANEL EDGES SHALL BE BLOCKED,
AND OCCUR WITHIN 24" OF MID-HEIGHT.(1) ROW OF TYP. SHEATHING-TO-FRAMING
NAILS ARE REQUIRED IN EACH PANEL.
GARAGE CORNER DETAILPER FIGURE R602.10.3(4) b(TYP)
LENGTH BASED ON
FASTEN SHEATHING TO HEADER WITH 8dCOMMON NAILS IN 3" GRID PATTERN ASSHOWN AND 3" O.C. IN FRAMING AS SHOWN(STUDS AND SILLS) (TYP)
FASTEN TOP PLATE TO HEADER WITH(2) ROWS OF 16d SINKER NAILS @ 3" O.C.(TYP)
OPT. BLOCKING FORGYPSUM WALLBOARD
C) GARAGE DOOR CORNER
8d NAILS @ 6" O.C.(PANEL EDGES)
MIN. 24" WOODSTRUCTURAL PANEL**
OPT. NON-STUCTURALFILLER PANEL
16d NAILS (2)ROWS @ 24" O.C.
CONTINUOUS WOODSTRUCTURAL PANEL
GYPSUM WALLBOARD(IN ACCORDANCE
w/ CHAPTER 7)
8d NAILS @ 12" O.C.(INTERMEDIATE SUPPORTS)
CONTINUOUS WOODSTRUCTURAL PANEL
B) INSIDE CORNER DETAIL
8d NAILS @ 6" O.C.(PANEL EDGES)
MIN. 24" WOODSTRUCTURAL PANEL**
16d NAILS@ 12" O.C.
GYPSUM WALLBOARD(IN ACCORDANCE
w/ CHAPTER 7)
8d NAILS @ 12" O.C.(INTERMEDIATE SUPPORTS)
A) OUTSIDE CORNER DETAIL
8d NAILS @ 6" O.C.(PANEL EDGES)
MIN. 24" WOODSTRUCTURAL PANEL**
OPT. NON-STUCTURALFILLER PANEL
16d NAILS@ 12" O.C.
CONTINUOUS WOODSTRUCTURAL PANEL
GYPSUM WALLBOARD(IN ACCORDANCE
w/ CHAPTER 7)
8d NAILS @ 12" O.C.(INTERMEDIATE SUPPORTS)
WALL HEIGHT, ft.
PANEL LENGTH, in.
8
16
9
18
10
20
11
22
12
24
WITH 2"X2"X3/16" PLATE WASHER
4' MAX PONY WALL HEIGHT
RIM BOARD
SIMPSON MSTA15HOLD DOWN
FLOOR SHEATHINGBOTTOM PLATE
(2)STUDS @ CORNER
WALL SHEATHING
SIMPSON MSTA15 HOLD DOWN CAPACITY OF 970POUNDS PER ANCHOR WITH (12) 10d NAILS.STRAP TO BE LOCATED AT EDGE OF BRACEDWALL PANEL.
RIM BOARD
SIMPSON MSTA15HOLD DOWN
FLOOR SHEATHINGBOTTOM PLATE
(2)STUDS @ CORNER
WALL SHEATHING
SIMPSON MSTA15 HOLD DOWN CAPACITY OF 970POUNDS PER ANCHOR WITH (12) 10d NAILS.STRAP TO BE LOCATED AT EDGE OF BRACEDWALL PANEL.
MIN. 1000# HEADER-TO-JACKSTUD