DATASHEET$FORTIMESCO$EES$$ … ·...

2
TIMESCO HEALTHCARE LTD., 3 Carnival Park, Carnival Close, Basildon, Essex, UK. T: +44 (0)1268 297 700, F: +44 (0)1268 297 800, E: [email protected], www.timesco.com, www.timescoees.com DATA SHEET FOR TIMESCO EES ION AND SHAKERSCOPE REUSABLE HANDLES & ION, ION R AND SHAKERSCOPE ENGINES. ION AND SHAKERSCOPE REUSABLE HANDLES Guaranteed for 10 years or a minimum of 500 autoclave cycles at up to 134° C for up to 18 minutes. Fully autoclaveable PSU Handle No moving or mechanical parts, to eliminate fitting issues and maintenance and repair costs. Stainless Steel over molded metal head for a secure fit, fully compatible with ISO 7376 Green fitting fibre optic laryngoscope blades. Sealed Optical Glass lens Internally keyed metal head to ensure only the right engine fits into each handle – SHAKERSCOPE Engine in SHAKERSCOPE Handle, ION engine in ION Handle. Over molded Silicon button to prevent fluid and dirt ingress to engine. Replaceable coloured Orings for department coding Indelible laser etched marking on handles. The following solutions are approved for use with ION and SHAKERSCOPE reusable Handles; please refer to the respective manufacturers guidelines for use. Aseptisol ®, Bleach Solutions 10%, Cavicide®, Envirocide®, Cidex®, Lysetol® FF, Hydrogen Peroxide 3%, Isopropyl Alcohol 70%, ManuKlenz ®,Phenols 2%, Puristeril Plus®, Quaternaries, SaniCloth® HB, Sporotal® 100, Super SaniCloth®. SINGLE USE SKIN HANDLE World’s only fully enclosed single use handle to work with kinetic, dry cell and rechargeable options. No moving or mechanical parts, to eliminate fitting issues and maintenance and repair costs. Fully compatible with ISO 7376 Green fitting fibre optic laryngoscope blades. Over molded silicon button to prevent fluid or dirt ingress to engine. Silicon button enlarged to cover any potential LED light flare from engine. Over molded Stainless Steel hook pin for strength. Will not break under normal use, built to exceed excessive pressure. Integral sealed plastic lens so engine is fully protected form cross infection. Internally keyed head will accept all engines; SHAKERSCOPE, ION & ION R. Secure fit end cap to protect the engine from cross infection. Visually clear to allow identification of internal engine and instructions for use. Clearly marked single use. Supplied in a compact box of 25 handles in individual polybags.

Transcript of DATASHEET$FORTIMESCO$EES$$ … ·...

         

TIMESCO  HEALTHCARE  LTD.,  3  Carnival  Park,  Carnival  Close,  Basildon,  Essex,  UK.      T:  +44  (0)1268  297  700,    F:  +44  (0)1268  297  800,    E:  [email protected],    www.timesco.com,    www.timesco-­‐ees.com  

DATA  SHEET  FOR  TIMESCO  EES    ION  AND  SHAKERSCOPE  REUSABLE  HANDLES    &  ION,  ION  R  AND  SHAKERSCOPE  ENGINES.      ION  AND  SHAKERSCOPE  REUSABLE  HANDLES  

 Guaranteed  for  10  years  or  a  minimum  of  500  autoclave  cycles  at  up  to  134°  C  for  up  to  18  minutes.  Fully  autoclaveable  PSU  Handle  No  moving  or  mechanical  parts,  to  eliminate  fitting  issues  and  maintenance  and  repair  costs.    Stainless  Steel  over  molded  metal  head  for  a  secure  fit,  fully  compatible  with  ISO  7376  Green  fitting  fibre  optic  laryngoscope  blades.  Sealed  Optical  Glass  lens  Internally  keyed  metal  head  to  ensure  only  the  right  engine  fits  into  each  handle  –  SHAKERSCOPE  Engine  in  SHAKERSCOPE  Handle,  ION  engine  in  ION  Handle.  Over  molded  Silicon  button  to  prevent  fluid  and  dirt  ingress  to  engine.  Replaceable  coloured  O-­‐rings  for  department  coding  Indelible  laser  etched  marking  on  handles.      

The  following  solutions  are  approved  for  use  with  ION  and  SHAKERSCOPE  reusable  Handles;  please  refer  to  the  respective  manufacturers  guidelines  for  use.    Aseptisol  ®,  Bleach  Solutions  10%,  Cavicide®,  Envirocide®,  Cidex®,  Lysetol®  FF,  Hydrogen  Peroxide  3%,  Isopropyl  Alcohol  70%,  Manu-­‐Klenz  ®,Phenols  2%,  Puristeril  Plus®,  Quaternaries,  Sani-­‐Cloth®  HB,  Sporotal®  100,  Super  Sani-­‐Cloth®.      

SINGLE  USE  SKIN  HANDLE    World’s  only  fully  enclosed  single  use  handle  to  work  with  kinetic,  dry  cell  and  rechargeable  options.  No  moving  or  mechanical  parts,  to  eliminate  fitting  issues  and  maintenance  and  repair  costs.    Fully  compatible  with  ISO  7376  Green  fitting  fibre  optic  laryngoscope  blades.  Over  molded  silicon  button  to  prevent  fluid  or  dirt  ingress  to  engine.  Silicon  button  enlarged  to  cover  any  potential  LED  light  flare  from  engine.  Over  molded  Stainless  Steel  hook  pin  for  strength.  Will  not  break  under  normal  use,  built  to  exceed  excessive  pressure.  Integral  sealed  plastic  lens  so  engine  is  fully  protected  form  cross  infection.  Internally  keyed  head  will  accept  all  engines;  SHAKERSCOPE,  ION  &  ION  R.  Secure  fit  end  cap  to  protect  the  engine  from  cross  infection.  Visually  clear  to  allow  identification  of  internal  engine  and  instructions  for  use.  Clearly  marked  single  use.  

 Supplied  in  a  compact  box  of  25  handles  in  individual  polybags.            

     

 

 

         

TIMESCO  HEALTHCARE  LTD.,  3  Carnival  Park,  Carnival  Close,  Basildon,  Essex,  UK.      T:  +44  (0)1268  297  700,    F:  +44  (0)1268  297  800,    E:  [email protected],    www.timesco.com,    www.timesco-­‐ees.com  

ION  DRY  CELL  Engine    Guaranteed  for  10  years.  A  typical  constant  LED  output  of  43,000  Lux  LED  life  cycle  of  500  hours  (over  30,000  intubations  or  16  years)*  Expected  battery  life  on  one  set  of  batteries  of  over  350  hours  (over  21,000  intubations  or  up  to  10  years)*  Requires  2  C  size  batteries,  we  recommend  alkaline  batteries.  Optimum  operating  temperature  range  is  dictated  by  the  Alkaline  battery  but  this  should  typically  be  between  -­‐20°C  and  +60°C.  Unique  locator  pin  to  ensure  insertion  only  in  ION  Reusable  handles  and  Single  Use  Skin  Handles.  Engine  will  flash  once  every  5  seconds  when  there  is  less  than  1  hour  of  battery  life  remaining.    Engine  will  flash  once  every  2  seconds  when  there  is  less  than  15  minutes  of  battery  life.  Engine  will  not  switch  on  if  there  is  less  than  5  minutes  of  battery  life.  Engine  will  switch  off  automatically  after  10  minutes  to  save  battery  life  if  left  on.                                                                                Patent  protected  behavior  mode  and  operating  cycles.    

 

ION  R  LITHIUM  RECHARGEABLE  Engine    Guaranteed  for  7  years.  Lithium  Ion  battery  life  cycle  of  typically  1,000  recharge  cycles.  A  typical  constant  LED  output  of  43,000  Lux  LED  life  cycle  of  500  hours  (over  30,000  intubations  or  16  years)*  Fully  charged  in  a  Timesco  ION  R  Charger  in  1  hour.  The  battery  and  not  the  handle  is  charged  in  the  charger  to  prevent  cross  infection  from  a  contaminated  handle.  Expected  battery  life  on  one  charge  of  over  41  hours  (over  2,500  intubations  or  up  to  12  months)*  The  World’s  only  rechargeable  system  made  for  single  use  handles.  Optimum  operating  temperature  range  between  -­‐20°C  and  +60°C.  Unique  locator  pin  to  ensure  insertion  only  in  ION  Reusable  handles  and  Single  Use  Skin  Handles.  Engine  will  flash  once  every  5  seconds  when  there  is  less  than  1  hour  of  battery  life  remaining.    Engine  will  flash  once  every  2  seconds  when  there  is  less  than  15  minutes  of  battery  life.  Engine  will  not  switch  on  if  there  is  less  than  5  minutes  of  battery  life.  

Engine  will  switch  off  automatically  after  10  minutes  to  save  battery  life  if  left  on.                                                                                 Patent  protected  behavior  mode  and  operating  cycles.      

SHAKESCOPE  KINETIC  ENERGY  Engine    Guaranteed  for  10  years.  The  World’s  only  kinetically  powered  laryngoscope/diagnostic  handle  system.  Shake  for  30  seconds  for  3  minutes  of  light.  A  typical  constant  LED  output  of  20,000  Lux  LED  life  cycle  of  500  hours  (over  30,000  intubations  or  16  years)*  Optimum  operating  temperature  range  between  -­‐20°C  and  +50°C.  Unique  locator  pin  to  ensure  insertion  only  in  SHAKERSCOPE  Reusable  handles  and  Single  Use  Skin  Handles.  Engine  will  flash  once  every  2  seconds  when  there  is  less  than  1  minute  of  battery  life  remaining.    Engine  will  flash  once  every  seconds  when  there  is  less  than  15  seconds  of  battery  life.  Engine  will  not  switch  on  if  there  is  less  than  3  minutes  of  battery  life.  Engine  will  hold  at  least  90%  of  its  charge  after  1  month  at  20°C.      Patent  protected  behavior  mode,  kinetic  system  and  operating  cycles.    

 *  Assuming  a  usage  time  of  1  minute  per  intubation,  5  intubations  per  day,  seven  days  per  week,  every  week  and  based  on  Alkaline  batteries  used  at  an  ambient  temperature  of  20°C.