CHIROPODY & PODIATRY - Timesco€¦ · CHIROPODY & PODIATRY 2016. 2 T +44 (0) 1268 297 710 F +44...

14
INTERNATIONAL BROCHURE CHIROPODY & PODIATRY 2016

Transcript of CHIROPODY & PODIATRY - Timesco€¦ · CHIROPODY & PODIATRY 2016. 2 T +44 (0) 1268 297 710 F +44...

  • INTERNATIONAL BROCHURE

    CHIROPODY & PODIATRY 2016

  • 2 T +44 (0) 1268 297 710 F +44 (0) 1268 297 801 E [email protected]

    Foot Dressers 3

    Cuticle Cut ter 3

    Nail Cut ters 3-6

    Canti lever Nail Cut ters 6

    Ingrown Nail Cut ter 6

    Nail Excavators 7

    Nail Fi les 7-9

    CONTENTS

    GUARANTEE

    TIMESCO HEALTHCARE | PODIATRY INSTRUMENTS

    Nail Probes 9

    Nail Spatulas 10

    Nail Elevators 10

    Nail Curet te 10-11

    Gauze Applicators 11

    Felt Scissors 11

    Cleaning Instructions 12-13

    Timesco Healthcare have over 50 years’ experience as manufacturers of Medical instrumentation. As a Worldwide provider of Podiatry instruments, we are now an established and highly recognised supplier throughout the world . We conform to ISO 13485 and all our instruments go through a highly stringent quality control process by our dedicated Quality Control Team at our Headquarters in Basildon, Essex, England.

    Our Export Department is also based at our Headquarters in the UK. This is managed by Mr Keith McVeigh, our International Sales Manager, Mr Simon Cox who is responsible for our European Market and supported by our internal Business Support Team, led by Mr Mark Lapping and Mrs Heather Nash. Please see below the contact details for the team, who will be delighted to assist you as necessary.

    Our Podiatry instruments are covered by an extensive 5 year guarantee or 4,000 autoclave cycles.

    The respective guarantee will be the number of years or the number of autoclave cycles, whichever is sooner and is from the date of purchase. Autoclave cycles are approved to 134ºC for 3 minutes holding time or 134ºC for 18 minutes holding time. If any of Timesco’s reusable products crack, bend, deform, corrode or fail whilst being used for the intended purpose within the guarantee period, we will repair it or replace it free of charge.

    Reusable Instruments: GuaranteeNumber of autoclave

    cycles

    Reusable instruments (excluding the sections of the products listed below) 5 years 4,000

    • The cutting, shearing, grinding and rasping edges (excluding Tungsten Carbide) 1 year 800

    • The cutting, shearing, grinding and rasping edges (Tungsten Carbide) 2 years 1,600

    MR KEITH MCVEIGH International Sales Manager

    T: 00 353 860 245 004 F: +44 (0) 1268 297 803E: [email protected]

    MR SIMON COXInternational Business Manager

    T: +44 (0) 7867 551 370 F: +44 (0) 1268 297 803E: [email protected]

    MR MARK LAPPING Sales Support Manager

    T: +44 (0) 1268 297 712 F: +44 (0) 1268 297 801E: [email protected]

    MRS HEATHER NASH Export Manager

    T: +44 (0) 1268 297 735 F: +44 (0) 1268 297 803E: [email protected]

    mailto:sales%40timesco.com?subject=Enquiry%20from%20International%20Podiatry%20Brochure%20mailto:keith.mcveigh%40timesco.com?subject=Podiatry%20Brochure%20Enquirymailto:simon.cox%40timesco.com?subject=Podiatry%20Brochure%20Enquirymailto:mark.lapping%40timesco.com?subject=Podiatry%20Brochure%20Enquirymailto:heather.nash%40timesco.com?subject=Podiatry%20Brochure%20Enquiry

  • 33T +44 (0) 1268 297 710 F +44 (0) 1268 297 801 E [email protected]

    FOOT DRESSERS, CUTICLE CUTTERS & NAIL CUTTERS

    • 9” (23cm) • Plastic Handle • Emery Coating• Single Patient Use

    • 8” (20cm) • Steel

    10.795.20 TIMESCO FOOT DRESSER 10.790.20 STEEL FOOT DRESSER

    • 7” (18cm) • Cardboard• Single Patient Use• Pack of 100

    *Colour may vary

    10.795.10 EMERY DRESSER

    10.155.40 CUTICLE CUTTER/TISSUE NIPPER

    • 4” (10cm) • Double Spring

    10.180.50 NAIL CUTTER, STRAIGHT

    • 4” (10cm) • Straight • Double Spring • Grooved Handles

    mailto:sales%40timesco.com?subject=Enquiry%20from%20International%20Podiatry%20Brochure%20

  • 4 T +44 (0) 1268 297 710 F +44 (0) 1268 297 801 E [email protected]

    10.185.50 NAIL CUTTER, STRAIGHT10.183.50 NAIL CUTTER, STRAIGHT

    10.187.50 NAIL CUTTER, CURVED 10.188.50 NAIL CUTTER, STRAIGHT

    • 5” (13cm) • Straight • Double Spring • Grooved Handles

    • Nail Cutter 4.5” (11.5cm) • Straight • Narrow • Double Spring

    • 5” (13cm) • Curved • Double Spring• Grooved Handles

    • 5” (13cm) • Straight • Double Spring • Fine Jaw • Grooved Handles

    10.188.50

    Straight Blade

    10.1

    87.5

    0

    Curved Blade

    NAIL CUTTERS

    mailto:sales%40timesco.com?subject=Enquiry%20from%20International%20Podiatry%20Brochure%20

  • 55T +44 (0) 1268 297 710 F +44 (0) 1268 297 801 E [email protected]

    • 6” (15.5cm)• Double Spring • Grooved Handles

    10.2

    27.5

    0

    Curved Blade

    10.225.50 NAIL CUTTER, STRAIGHT

    10.225.50

    Straight Blade

    • 6” (15.5cm) • Double Spring • Grooved Handles

    10.227.50 NAIL CUTTER, CURVED

    10.188.50 NAIL CUTTER, STRAIGHT

    • 5” (13cm) • Straight • Double Spring • Fine Jaw • Grooved Handles

    NAIL CUTTERS

    10.255.50

    Straight Blade

    10.2

    75.5

    0

    Curved Blade

    • 5.5” (14cm) • Double Spring • Lock & Smooth Handles

    10.255.50 NAIL CUTTER, STRAIGHT

    • 5.5” (14cm) • Double Spring • Lock & Smooth Handles

    10.275.50 NAIL CUTTER, CURVED

    mailto:sales%40timesco.com?subject=Enquiry%20from%20International%20Podiatry%20Brochure%20

  • 6 T +44 (0) 1268 297 710 F +44 (0) 1268 297 801 E [email protected]

    10.275.65

    Straight Blade

    10.2

    75.7

    5

    Curved Blade

    • 5.5” (14cm) • Double Spring • Lock & Diamond Knurled Handles

    10.275.65 NAIL CUTTER, STRAIGHT

    • 5.5” (14cm) • Double Spring • Lock & Diamond Knurled Handles

    10.275.75 NAIL CUTTER, CURVED

    Chisel End

    10.356.50S THWAITE INGROWN NAIL CUTTER

    • 5.75” (14.5cm) • Anvil Type Chisel End • Pointed Cutting Jaw • Grooved Handles

    10.325.51 CANTILEVER NAIL CUTTER, CURVED

    • 6” (15.5cm) • Double Spring • Lock & Knurled Handles

    NAIL CUTTERS

    mailto:sales%40timesco.com?subject=Enquiry%20from%20International%20Podiatry%20Brochure%20

  • 77T +44 (0) 1268 297 710 F +44 (0) 1268 297 801 E [email protected]

    Course Cut

    • 7” (18cm) • Double Ended

    10.540.20 NAIL EXCAVATOR & FILE

    Excavator

    File

    10.560.20 BAK A NAIL FILE

    Extra Fine Cut

    • 4.75” (12cm) • Extra Small Head • Extra Fine Cut

    10.570.40 NAIL FILE 10.570.60 NAIL FILE

    Fine Cut

    • 5.5” (14cm) • Medium Head • Fine Cut

    • 5.5” (14cm)• Coarse

    NAIL EXCAVATORS & FILES

    10.520.20 NAIL EXCAVATOR 10.500.20 NAIL EXCAVATOR

    • 6.25” (16cm) • Angled • Round Head

    • 6.5” (16.5cm) • Double Ended• Swan Neck• Flat

    Angled Swan Neck

    mailto:sales%40timesco.com?subject=Enquiry%20from%20International%20Podiatry%20Brochure%20

  • T +44 (0) 1268 297 710 F +44 (0) 1268 297 801 E [email protected]

    • 6.25” (16cm) • Medium Heads • Straight/Angled• Medium Cut• Double Ended

    10.595.20 NAIL FILE

    Angled Head

    Straight Head

    10.603.20 NAIL FILE

    Medium Cut

    • 5.5” (14cm) • Small Head • Medium Cut

    NAIL FILES

    10.592.20 NAIL FILE

    Straight Head

    Curved Head

    Swan Neck Probe

    • 5.5” (14cm) • Narrow Heads • Straight/Curved • Medium Cut* Double Ended

    10.590.60 NAIL FILE 10.590.80 NAIL FILE

    • 6” (15.5cm) • Extra Fine • Medium Heads• Double Ended

    • 5.5” (14cm) • Swan Neck Probe• Double Ended

    Medium Head File

    10.590.40 NAIL FILE

    Coarse Cut

    Fine Cut

    • 6” (15.5cm) • Medium Heads • Fine/Coarse Cut• Double Ended

    mailto:sales%40timesco.com?subject=Enquiry%20from%20International%20Podiatry%20Brochure%20

  • 99T +44 (0) 1268 297 710 F +44 (0) 1268 297 801 E [email protected]

    • 5.5” (14cm) • Angled • Flat Head

    Angled

    10.710.40 NAIL PROBE

    NAIL FILES & PROBES

    10.605.20 NAIL FILE

    Medium Cut

    • 6” (15.5cm) • Medium Head • Medium Cut

    Fine Cut

    10.610.20 NAIL FILE 10.620.20 NAIL FILE

    Medium Cut

    • 4.5” (11.5cm) • Medium Head • Medium Cut

    • 5.5” (14cm) • Extra Narrow Head• Fine Cut

    Swan Neck

    • 5.5” (14cm) • Swan Neck • Flat

    • 5.5” (14cm) • Swan Neck • Flat • Fine Cut

    Swan Neck

    10.715.20 NAIL PROBE 10.716.20 NAIL PROBE

    mailto:sales%40timesco.com?subject=Enquiry%20from%20International%20Podiatry%20Brochure%20

  • T +44 (0) 1268 297 710 F +44 (0) 1268 297 801 E [email protected]

    • 6.25” (16cm) • Double Ended • Curved• Round/Point

    10.440.20 FICKLING NAIL ELEVATOR 10.445.20 FICKLING NAIL ELEVATOR

    10.470.20 NAIL ELEVATOR

    • 5.5” (14cm)

    • 5” (13cm)

    NAIL SPATULAS, PROBE WITH SPATULA & ELEVATORS

    • 4.5” (11.5cm)

    10.665.20 NAIL SPATULA 10.740.20 NAIL PROBE & SPATULA

    • 6.25” (16cm) • Double Ended

    • 5.5” (14cm) • Swan Neck • Cup

    10.718.20 NAIL PROBE

    Swan Neck

    mailto:sales%40timesco.com?subject=Enquiry%20from%20International%20Podiatry%20Brochure%20

  • 1111T +44 (0) 1268 297 710 F +44 (0) 1268 297 801 E [email protected]

    10.960.40 GAUZE APPLICATOR

    • Small Size 00

    10.960.70 GAUZE APPLICATOR

    • Large Size 0

    • 5” (13cm) • 2mm, No Hole

    • 5” (13cm) • 1.5mm, No Hole

    1mm scoop with hole 1.5mm scoop - no hole 2mm scoop - no hole

    2mm scoop with hole

    10.398.30 NAIL CURETTE

    10.396.20 NAIL CURETTE

    10.396.30 NAIL CURETTE

    • 5.5” (14cm) • Double Ended • 1mm Scoop with Hole• 2mm Scoop with Hole

    NAIL CURETTES, GAUZE APPLICATORS & FELT SCISSORS

    10.090.40 FELT SCISSORS

    • 6” (15.5cm) • Straight • Heavy • Blunt/Sharp

    mailto:sales%40timesco.com?subject=Enquiry%20from%20International%20Podiatry%20Brochure%20

  • 12 T +44 (0) 1268 297 710 F +44 (0) 1268 297 801 E [email protected]

    INSTRUCTIONS FOR RE-PROCESSING TIMESCO REUSABLE INSTRUMENTS

    The following instructions are for all Timesco reusable instruments by Timesco Healthcare, unless stated otherwise with the packaging of the product. All reusable devices are supplied non sterile and should be cleaned and sterilised before first use and after each subsequent use. These instructions are intended for use only by persons with the required specialist knowledge and training.

    WARNINGS • Follow instructions and warnings as issued by manufacturers of any decontaminants, disinfectants and cleaning agents used. Wherever

    possible avoid use of mineral acids and harsh, abrasive agents. • Do not use chemical sterilants with caustic ingredients such as: surgical scrub solutions, povidone-iodine solutions, bleach, peroxide

    solutions, Virox 3, Sporox and Cidex PA. Do not use garment or surface disinfectants.• Do not autoclave with sub standard stainless steel surgical instruments as this may cause a reaction and lead to rust or discolourisation.• No part of the process shall exceed 140º C. • Ultrasonic cleaning is not permitted, as this will cause damage to the glass fibre optic bundle.• Do not flash autoclave, this will invalidate our guarantee.• When reprocessing medical devices, handle with care, wearing protective clothing and face visors or goggles where appropriate. • Batteries must be removed from any battery operated devices before reprocessing.

    LIMITATIONS ON REPROCESSING • These reprocessing instructions will have a minimal effect on all devices, but repeated autoclaving, especially for extended periods can

    affect certain devices.

    INSTRUCTIONS FROM POINT OF USE • If possible, soiled devices should be placed in a holding solution (combined disinfectant/enzyme solution) immediately after use and prior to

    cleaning.

    PREPARATION FOR DECONTAMINATION • Reprocess all devices as soon as it is reasonably practical to do so. • Where necessary disassemble devices that require disassembly for adequate cleaning and reprocessing.

    CLEANING: MANUAL• Some devices cannot be effectively cleaned by a washer-disinfector, those items should be manually cleaned as follows and then cleaned

    in a washer-disinfector as below:• Using a sink dedicated for instrument cleaning (not used for hand washing), rinse excess soil from the device (water temp

    mailto:sales%40timesco.com?subject=Enquiry%20from%20International%20Podiatry%20Brochure%20

  • 1313T +44 (0) 1268 297 710 F +44 (0) 1268 297 801 E [email protected]

    STERILISATION • Either CE marked or validated vacuum autoclave operating at 134-137 ºC 2.25 bar for a minimum holding time of 3 minutes - always following

    the instructions of the machine manufacturer.• When sterilising multiple instruments in one autoclave cycle, ensure that the steriliser manufacturer’s stated maximum load is not exceeded.• Ensure all devices are dry before sterilisation. If the devices cannot be dried prior to sterilisation, then use distilled/de-ionised water in the

    final-rinse stage of cleaning.

    Timesco devices have been validated to the following steriliser cycle:Sterilising temperature 134 ºC, Sterilising time 3 minutes, 10 seconds, Normal drying time 5 minutes, Extended Drying time 15 minutes.

    STORAGE• Ensure all devices are dry before storage, and stored in dry, clean conditions at an ambient room temperature.

    ADDITIONAL INFORMATION • Other forms of cleaning (alkaline and neutral) and sterilisation (Cidex OPA, Ethylene oxide up to 65 ºC for anaesthetic devices) are permitted.

    However, always follow the instructions for use as issued by Timesco and always consult with us if in any doubt over the suitability of any processused.

    • Follow cleaning and sterilising guidelines as per HTM 2030 and HTM 2010.

    MANUFACTURER Timesco Healthcare Ltd, Timesco House, 3 Carnival Park, Carnival Close, Basildon, Essex, SS14 3WN, England. E-mail [email protected], Website www.timesco.com

    NOTE: IT IS THE RESPONSIBILITY OF THE REPROCESSOR TO ENSURE THAT THE REPROCESSING AS ACTUALLY PERFORMED USING EQUIPMENT, MATERIALS AND PERSONNEL IN THE REPROCESSING FACILITY ACHIEVE THE DESIRED RESULT. THIS REQUIRES VALIDATION AND ROUTINE MONITORING OF THE PROCESS. LIKEWISE ANY DEVIATION BY THE REPROCESSOR FROM THE INSTRUCTIONS PROVIDED MUST BE PROPERLY EVALUATED FOR EFFECTIVENESS AND POTENTIAL ADVERSE CONSEQUENCES.Virox 3, Sporox, Cidex PA, Instro-Klenz, Enzycare, Olympic Spraydry 1000 and Sprayclean 2000 are trademarks of their respective companies.

    PRODUCT GUARANTEE Timesco offer extensive guarantees across our range of reusable surgical products, users should refer to the specific guarantees provided with each product. These guarantees do not cover consumables or disposable items, fair wear and tear or any damage caused by misuse. Any alteration or marking of the product in any way will also invalidate these guarantees and the CE mark.

    RETURNING INSTRUMENTS TO TIMESCO Products returned to Timesco Healthcare Ltd must be accompanied by a decontamination certificate, which states that each instrument has been thoroughly cleaned and disinfected. Timesco reserve the right to immediately dispose of any products that are returned without evidence of adequate cleaning and disinfection. Please contact our customer services team for authorisation before returning any product as we may be able to resolve your query or arrange a replacement without the product having to be returned.

    INSTRUCTIONS FOR RE-PROCESSING TIMESCO REUSABLE INSTRUMENTS

    mailto:sales%40timesco.com?subject=Enquiry%20from%20International%20Podiatry%20Brochure%20

  • E & O.E TIMESCO HEALTHCARE LTD. APRIL 2016. REF B.F.006/ 1

    Timesco are the UK’s premier manufacturer of medical devices for

    Anaesthesia, Surgery, Podiatry and Primary Care since 1964.

    Timesco Healthcare Ltd Timesco House 3 Carnival Park Carnival Close Basildon Essex SS14 3WN England

    T +44 (0) 1268 297 700 | F +44 (0) 1268 297 800

    E [email protected] | timesco.com

    mailto:info%40timesco.com?subject=Information%20Request%20from%20International%20Podiatry%20Brochurehttp://www.timesco.com