Datasheet solids – Big-Bag-Filling Device BFA-02-Hygienic · BFA-02-Hygienic solids solutions...

4
Datasheet solids – Big-Bag-Filling Device BFA-02-Hygienic solids solutions group www.solids.eu O:\SST-Solids Components\3. solids Befülleinrichtungen\04_BFA-02-Hygienic\DA_BFA-02-Hygienic_EN_200917.doc Seite 1 von 4 Operating conditions: Permissible operating pressure: atmospheric Max. temperature:40°C Max/min ambient temperature: -10°C T 40°C Bulk solid data: Particle size: powders, granules till lumpy, every hardness Fluidity: for products from free flowing up to difficult flowing Type Width x Depth (mm) Height (mm) Big Bag Dimensions: Width x Depth x Height (incl. loops) Weight BFA1200Y02 1600 x 1600 2700 max. 1200 x 1200 x 2200 mm min. 800 x 800 x 1500 mm 400 kg Basical version: Hygienic design for food, pharmaceutical, cosmetic und chemical industry Construction free from dead zones and gaps Easy to clean, accessible from 3 sides Surfaces in contact with the product: Ra < 0,8 μm (sheet metal), weldings inside polished Ra < 0,8 μm, outside Ra < 3,0 μm Outside Pickled or brushed and passivated According to EU regulations, Machinery Directive, EHEDG guidelines and DIN1672-2 Big-bag-filling head with nozzle for dust-thight docking of the big-bag inlet tube, welded steel construction, made of stainless steel 1.4306 (DIN) / 304L (AISI), dust-tight docking with inflatable collar incl. pneumatic installation Outlet for imposing of the big-bag inlet tube, diameter of the big-bag inlet tube 350 mm 1 aspiration connection DN 80 for on-site dust extraction 4 hooks for big-bag loops, adjustable to the position of the loops Frame made of square tube of carbon steel With weighing frame and 4 weighing modules made of stainless steel, equipped with load cells for max. big-bag-weight 1800 kg Lower frame support made of carbon steel Surface treatment of carbon steel parts: Chemical stripped, primer 40 μm zinc phosphate, top coat 40 μm 2-component polyurethane, RAL5012 blue approval: MIGSA SST H. Linder Date: Sign: Date: Sign: Date: Sign: Preliminary modifications reserved

Transcript of Datasheet solids – Big-Bag-Filling Device BFA-02-Hygienic · BFA-02-Hygienic solids solutions...

Page 1: Datasheet solids – Big-Bag-Filling Device BFA-02-Hygienic · BFA-02-Hygienic solids solutions group O:\SST-Solids Components\3. solids Befülleinrichtungen\04_BFA-02-Hygienic\DA_BFA-02-Hygienic_EN_200917.doc

Datasheet

solids – Big-Bag-Filling Device BFA-02-Hygienic

solids solutions group www.solids.eu

O:\SST-Solids Components\3. solids Befülleinrichtungen\04_BFA-02-Hygienic\DA_BFA-02-Hygienic_EN_200917.doc Seite 1 von 4

� Operating conditions:

� Permissible operating pressure: atmospheric � Max. temperature:40°C � Max/min ambient temperature: -10°C ≤ T ≤ 40°C � Bulk solid data: Particle size: powders, granules till lumpy, every hardness

Fluidity: for products from free flowing up to difficult flowing

Type Width x Depth

(mm) Height (mm)

Big Bag Dimensions: Width x Depth x Height (incl. loops)

Weight

BFA1200Y02 1600 x 1600 2700 max. 1200 x 1200 x 2200 mm

min. 800 x 800 x 1500 mm 400 kg

Basical version:

� Hygienic design for food, pharmaceutical, cosmetic und chemical industry Construction free from dead zones and gaps Easy to clean, accessible from 3 sides Surfaces in contact with the product: Ra < 0,8 µm (sheet metal), weldings inside polished Ra < 0,8 µm, outside Ra < 3,0 µm Outside Pickled or brushed and passivated According to EU regulations, Machinery Directive, EHEDG guidelines and DIN1672-2

� Big-bag-filling head with nozzle for dust-thight docking of the big-bag inlet tube, welded steel construction, made of stainless steel 1.4306 (DIN) / 304L (AISI), dust-tight docking with inflatable collar incl. pneumatic installation

� Outlet for imposing of the big-bag inlet tube, diameter of the big-bag inlet tube 350 mm

� 1 aspiration connection DN 80 for on-site dust extraction

� 4 hooks for big-bag loops, adjustable to the position of the loops

� Frame made of square tube of carbon steel � With weighing frame and 4 weighing modules

made of stainless steel, equipped with load cells for max. big-bag-weight 1800 kg

� Lower frame support made of carbon steel � Surface treatment of carbon steel parts: Chemical

stripped, primer 40 µm zinc phosphate, top coat 40 µm 2-component polyurethane, RAL5012 blue

approval: MIGSA SST H. Linder

Date:

Sign:

Date:

Sign:

Date:

Sign:

Preliminary modifications reserved

Page 2: Datasheet solids – Big-Bag-Filling Device BFA-02-Hygienic · BFA-02-Hygienic solids solutions group O:\SST-Solids Components\3. solids Befülleinrichtungen\04_BFA-02-Hygienic\DA_BFA-02-Hygienic_EN_200917.doc

Datasheet

solids – Big-Bag-Filling Device BFA-02-Hygienic

solids solutions group www.solids.eu

O:\SST-Solids Components\3. solids Befülleinrichtungen\04_BFA-02-Hygienic\DA_BFA-02-Hygienic_EN_200917.doc Seite 2 von 4

Options:

1. Big-bag-filling head made of stainless steel 1.4404 (DIN) / 316L (AISI)

2. Big-bag-filling head made of stainless steel 1.4571 (DIN) / 316Ti (AISI)

3. Docking unit electropolished

4. Frame galvanized

5. Frame made of stainless steel 1.4306 (DIN) / 304L (AISI)

6. ---

7. Lower frame support galvanized

8. Lower frame support made of stainless steel 1.4306(DIN) / 304L (AISI)

9. Frame, load cells and raising cylinder for max. big-bag-weight 2000 kg

10. Another outlet diameter for imposing of the big-bag inlet tube, diameter of the big-bag inlet tube >350 mm

11. 4 suspension hooks for big-bag loops,

pivoting pneumatically

12. 2 suspension hooks for big-bag loops,

moving pneumatically

13. Vibrating table for compacting the product and displacing the air, based on air suspensions/lifting bellows, vibration drive with 2 vibration motors 230/400V IP65

Page 3: Datasheet solids – Big-Bag-Filling Device BFA-02-Hygienic · BFA-02-Hygienic solids solutions group O:\SST-Solids Components\3. solids Befülleinrichtungen\04_BFA-02-Hygienic\DA_BFA-02-Hygienic_EN_200917.doc

Datasheet

solids – Big-Bag-Filling Device BFA-02-Hygienic

solids solutions group www.solids.eu

O:\SST-Solids Components\3. solids Befülleinrichtungen\04_BFA-02-Hygienic\DA_BFA-02-Hygienic_EN_200917.doc Seite 3 von 4

14. Table for lifting the big-bag and for different big-bag heights, hydraulically activated, max. 2000 kg

15. Roll conveyor integrated in the filling station for bringing in / moving out of pallets before and after the filling, with gearboxmotor and photoelectric barrier

16. Stopper for the exact position of the empty

pallets, pneumatically activated

17. Pallet centering for empty pallets, pneumatically activated

18. Opening in the roll conveyor for the vibrating table

19. Pneumatic installation for inflating the big-

bag incl. safety valve and pressure sensor

20. Control of the aspiration with 2 butterfly valves incl. piping and weighing decoupling

21. Earthing gripper for the big-bag and earthing connections for the filling station

Page 4: Datasheet solids – Big-Bag-Filling Device BFA-02-Hygienic · BFA-02-Hygienic solids solutions group O:\SST-Solids Components\3. solids Befülleinrichtungen\04_BFA-02-Hygienic\DA_BFA-02-Hygienic_EN_200917.doc

Datasheet

solids – Big-Bag-Filling Device BFA-02-Hygienic

solids solutions group www.solids.eu

O:\SST-Solids Components\3. solids Befülleinrichtungen\04_BFA-02-Hygienic\DA_BFA-02-Hygienic_EN_200917.doc Seite 4 von 4

22. Welding device devided from the station for the inliner-inlet, Ex-free, temperature controlled, complete with temperature-indication (adjustable), with pneumatically movable welding rails

23. In the station integrated welding device for the inliner-inlet, not usable for products with dust explosion danger, temperature controlled, complete with temperature-indication (adjustable), with pneumatically movable welding rails

24. Safety related protection of the moving area of the lifting table

25. Control box made of stainless steel with pneumatic installation of the pilot-valves incl. tubes to the pneumatic drives

26. Calibratable evaluation electronics for

assembly in the control box

27. Suitable for zone 20 inside, zone 22 outside according to ATEX 2014/34/EU, not valid for the welding device

28. Suitable for zone 20 inside, zone 21 outside according to ATEX 2014/34/EU, not valid for the welding device

Related documents: 3D-Part: Type.step (example: BFA1200Y02. Step) 2D-planning drawing: Type.dxf (example: BFA1200Y02. dxf) Selection criteria: SG-BFA Pricelist: PL- BFA-02-Hygienic Drawing numbers list: Draw-No-List_BFA-02-Hygienic