33-126 NEMA Contactors & StartersStarters — Non-reversing and Reversing
Cutler-Hammer
A200 Line
January 2001Vol. 2, Ref. No. [0142]
Size 3 Starter
Product Selection —Non-reversing, Sizes 00-9When Ordering SpecifyOrder by Catalog Number from Table33-191, plus Suffix for coil voltages,verifying usage of appropriate sizes.
HeatersEnter heaters as separate item bylisting Catalog Number from tables,Pages 33-148 - 33-149, as requiredper starter.
Table 33-191. Non-reversing Starters Selection<
Size Amps Max. UL Horsepower1-Phase115V 230V
3-Phase208V 240V 480V 600V
2 Poles®OpenCatalogNumber®
PriceU.SS
3 PolesOpenCatalogNumber®
PriceU.S. $
Sizes 00-600
011-1/2
234
56
918
27
36
45
90
135
270
540
1/31
2
3
7-12
—
—
—
—
—
—
—
—
—
—
—
—
—
1-1/2
37-1/2
—
1025
40
75
150
1-1/23
7-1/2
—
153050
100
200
2
5
10
—
25
50100200400
25
10—
2550
100200400
A200MABRA200MOBRA200M1BRA200MDBRA200M2BR————
193.
217.
279.
330.
505.
—
—
—
—
A200MAC_A200MOC_A200M1C_—A200M2C.A200M3C.A200M4C.A200M5C_A200M6C.
193.242.279.
—505.820.
1,870.4,565.
10,840.Sizes 7- 97®8®9®
81012152250
———
———
200400
—
300
450
800
600
9001600
600900—
———
———
A200M7C,A200M8C,A200M9C_ ®
16,100.24,100.38,900.
'i> For ambient compensated overload relay with auto-reset, add Suffix D.® Sizes 7-9 use rectifier with DC coil.S Single-phase with one single-pole overload relay.£' For Size 9, only available coil voltage is 120V.
Table 33-192. Coils for Sizes 00-6Coil Volts and Hz Code Suffix
120/60 or 110/50200 - 208/60240/60480/60600/60
ACB
WXE
Table 33-193. Coils for Sizes 7,8 and 9 ©Coil Volts and Hz Code Suffix
110 -120/50 or 60220 - 240/50 or 60440 - 480/50 or 60600/60
JWXE
® For Size 9, only available coil voltage is120V.
Factory Modifications..... Page 33-133Modification Kits,Accessories............ Pages33-133-33-135
Dimensions.............. Page 33-123Discount Symbol......... 1CD1
F:T*N For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.201.01.T.E
Cutler-HammerJanuary 2001Vol. 2, Ref No. [0137]
NEMA Contactors & StartersStarters — Non-reversing and Reversing 33-121
A200 Line
ContentsDescription
Starters — Non-reversing andReversing . . . . . . . . . . . . . . .
Product Description —Sizes 00-4............
Product Description —Sizes 5-9. . . . . . . . . . . . .
Features and Benefits ....Instructional Leaflets . . . . .Dimensions and
Shipping Weights . . . . . .Product Selection —
Non-reversing,Sizes 00 -9 . . . . . . . . . . . .
Product Selection —Reversing,Sizes 00-9. . . . . . . . . . . .
Starters — Two-Speed......Technical D a t a . . . . . . . . . . . . .Factory Modifications.......Accessories and Field
Modification Kits . . . . . . . . .Renewal Parts . . . . . . . . . . . .
Page
33-121
33-121
33-12133-12233-122
33-123
33-126
33-12733-12833-12933-133
33-13333-136
Size 1 Starter
Product Description —Sizes 00-4GeneralMagnetic starters are used for full-voltage, across-the-line starting andstopping of squirrel cage motors. Theycan be operated locally or remotely bymanual or automatic pilot devices.
NEMA Sizes 00-4;Three-Phase, 1-1/2 -100 hpThese starters use Class A201 contac-tors as described on Page 33-115.Contactor features are enhancedthrough the ability to provide positivemotor protection in the form of severaltypes of overload relays. See Pages33-141-33-149
Type B Overload Relay, Manual Reset OnlySupplied as standard on Class A200and A900 starters (two-speed). The bi-metallic overload relay offers ambientcompensation and trip-to-test feature(relay contact status check) as stan-dard. In addition, an isolated normally-open contact is available in kit form forcustomer mounting. Type B overloadrelays are manual reset only.
Type A Overload Relay, Manualor Automatic ResetThis is an optional overload relay,offering the capability of field conver-sion to automatic reset. It is availableas an ambient compensated or non-compensated type.
Non-reversing StartersNon-reversing starters are supplied asopen devices. All starters are suppliedwith a normally-open holding circuitinterlock.
Class A200 starters are available as ULlisted or recognized components, aswell as with CSA certification.
Reversing StartersFor reversing applications (ClassA210), a starter and a contactor electri-cally and mechanically interlocked aresupplied on a common baseplate.Reversing starters are used to start,stop and reverse AC squirrel cagemotors and for primary control ofreversing wound-rotor motors.
For plugging or inching, when opera-tions exceed five times per minute,decreased horsepower ratings inaccordance with NEMA Standard ICS2-321 are recommended.
Two-Speed Starters, A900sFor across-the-line starting of two-speed constant hp, constant torqueand variable torque squirrel cagemotors, two-speed starters (ClassA900) are available. These startersconsist of two starters, one for eachmotor speed, mechanically and electri-cally interlocked and wired for manualspeed selection by means of pushbut-tons. Auxiliary relays may be added toprovide automatic acceleration ordeceleration.
Starters for two-speed, two indepen-dent winding motors consist of two-,three- or four-pole starters electricallyand mechanically interlocked. Startersfor two-speed, single reconnectablewinding motors consist of one three-pole and one five-pole starter mechan-ically and electrically interlocked.
Size 5 Starter
Product Description —Sizes 5-9NEMA Sizes 5-9;Three-Phase 75 to 1600 hpNon-reversing (Class A200), andreversing (Classes A210, A250) fullvoltage starters are used for across-the-line starting of squirrel cage induc-tion motors. They are used withmotors rated above 50 hp at 230V, andabove 100 hp at 460 through 600V.
Sizes 5 and 6 starters use Class A201contactors as described on Page 33-1 1 6 . In addition to standard motorstarters, special application devicesare available: Sizes 5 and 6 starterswith integrally rectified AC to DC coilsfor applications where low voltageproblems are prevalent are available.
Class A200 starters are UL listedand recognized and also carry CSAcertification.
Front Removable Parts — All operat-ing parts can be removed quickly andeasily from the front. Straight-throughwiring and conveniently located con-nection points for external wires andcables minimize installation time.
Type B Block Type Thermal OverloadRelay — Dependable overload protec-tion is assured by these snap-action,manual reset relays. Automatic resetType A relays are available as anoption.
Technical Data Pages 33-129-33-132
CAT.201.01.T.E For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog E:T«N
33-132 NEMA Contactors & StartersTechnical DataA200 Line
Cutler-HammerJanuary 2001
Vol. 2, Ret No. [01481
Combination RatingsTable 33-209. Combination Ratings — Sizes 00-2Short-CircuitProtective Device(SCPD)
Max.RatingSCPD
Circuit BreakerInterruptingRating
Short-CircuitWithstand CapabilityCurrent Voltage
Sizes 00,0,1Class H FuseClass J FuseClass R FuseClass T FuseMagnetic Only®Type CB £
Thermal/Mag.Type CB 3)
Magnetic OnlyTypeCB + CL®Thermal/Mag.Type CLB ®
60A60A60A60A30A
50A
30A
BOA
—
Marked HMCP
65.000A25,OOOA
100.000A35.000A
HMCP +Current Limiter150,OOOA
5,OOOA100.000A100.000A100,OOOA100.000A50.000A65.000A25.000A
100.000A35.000A
100,OOOA
100.000A
600V600V600V600V480V600V480V600V480V600V600V
480V
Size 2Class H FuseClass J FuseClass R FuseClass T FuseMagnetic Only ©Type CB ®
Thermal/Mag.Type CB 'S
Magnetic OnlyTypeCB + CL®Thermal/Mag.Type CLB ®
100A100A100A100A50A
90A
BOA
50A
—
Marked HMCP
65.000A25.000A
100.000A35.000A
HMCP +Current Limiter150,OOOA
5,OOOA100.000A100.000A100,OOOA100,OOOA50.000A65.000A25,OOOA
100.000A35,OOOA
100,000 A
100.000A
600V600V600V600V480V600V480V600V480V600V600V
480V
® Instantaneous Adjustable Trip.® Circuit Breaker.® Inverse Time Circuit Breaker.® Instantaneous Adjustable Trip with Current Limiting Attachment.® Inverse Time with Built-in Current Limiting Attachment.
Coil SuffixTable 33-211. Other Available Coil Voltages — AC and DC CoilsCoils
AC
DC®®®
CatalogNumberSuffix
ABC®DEGH1J
K
LM
Coil Rating(Volts/Hertz)
120/60,110/50200-208/60240/60 and 480/60440/50600/60 Hz220/50380/5024/60110-120/50 or60 Reel, to DC
220-240/50 or60 Rect. to DC
24V DC48V DC
CatalogNumberSuffix
NPQ®R®U
VwXYz
sT
Coil Rating(Volts/Hertz)
110/5048/60AC/DC Volts Specified120/60 and 240/60440-480/50 or60 Rect. to DC
110/60240/60480/60415/50277/60
125V DC250V DC
® List Price Addition for dual voltage coils. Consult Sales Office or Price List.® List Price Addition for DC coils. Consult Sales Office or Price List.® DC coils for Size 5 and 6 contactors and starters are intermittent duty
rated only. A mechanical latch is required.© DC coils. Use only on contactors originally supplied with a DC coil.© For Q suffixes "order by description" consult Technical Support Center.
Table 33-210. Combination Ratings — Sizes 3 and 4Short-CircuitProtective Device(SCPD)
Max.RatingSCPD
Circuit BreakerInterruptingRating
Short-CircuitWithstand CapabilityCurrent Voltage
Size3Class H FuseClass J FuseClass R FuseClass T FuseMagnetic Only®Type CB ®
Thermal/Mag.TypeCB®
Magnetic OnlyType CB + CL ®Thermal/Mag.TypeCLB®
60A60A60A60A
100A
150A
100A
150A
—
Marked HMCP
65.000A25,OOOA
100.000A35.000A
HMCP +Current Limiter50.000A
5.000A100.000A100.000A100.000A100.000A50.000A65.000A25.000A
100.000A35,OOOA
100.000A
100.000A
600V600V600V600V480V600V480V600V480V600V600V
480V
Size 4Class H FuseClass J FuseClass R FuseClass T FuseMagnetic Only®Type CB <i>Thermal/Mag.Type CB ®
Magnetic OnlyType CB + CL ®Thermal/Mag.Type CB + CL ®Thermal/Mag.TypeCLB®
400A400A400A400A150A
250A
150A
250A
250A
—
Marked HMCP
65.000A25.000A
100.000A35.000A
HMCP +Current Limiter200.000A
150.000A
10.000A100.000A100.000A100.000A100.000A50.000A65.000A25,OOOA
100.000A35.000A
100.000A
100.000A
100.000A
600V600V600V600V480V600V480V600V480V600V600V
600V
480V
® Instantaneous Adjustable Trip.© Circuit Breaker.® Inverse Time Circuit Breaker.® Instantaneous Adjustable Trip with Current Limiting Attachment.® Inverse Time with Built-in Current Limiting Attachment.® Inverse Time Current Limiting Breaker.
Table 33-212. Other DC Coils Available (For Q Suffix) ©Voltages
1228323437.54050
Sizes 0 & 11-to4-Pole
Size 21-to3-Pole
Style Number
1268C86G071268C86G061268C86G091268C86G161268C86G171268C86G131268C86G10
Voltages
79
96
200
300
315
125/250
Sizes 0 & 11-to4-Pole
Size 21-to3-Pole
Style Number
1268C86G081268C86G151268C86G111268C86GH1268C86G121268C86G03—
For Q suffixes "order by description" consult Technical Support Center.
F:T*N For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.201.01.T.E