March 26, 2014
Melanie A. Bachman Connecticut Siting Council 10 Franklin Square New Britain, CT 06051
RE: T-Mobile-Exempt Modification - Crown Site BU: 876313 T-Mobile Site ID: CT11453C Located at: 1394 Route 322, Southington, CT 06410
Dear Ms. Bachman:
This letter and exhibits are submitted on behalf of T-Mobile. T-Mobile is making modifications to certain existing sites in its Connecticut system in order to implement their Modernization technology. Please accept this letter and exhibits as notification, pursuant to § 16-50j-73 of the Regulations of Connecticut State Agencies (“R.C.S.A.”), of construction that constitutes an exempt modification pursuant to R.C.S.A. § 16-50j-72(b)(2). In compliance with R.C.S.A. § 16-50j-73, a copy of this letter is being sent to Mr. Garry Brumback, Town Manager for Town of Southington.
T-Mobile plans to modify the existing wireless communications facility owned by Crown Castle and located at 1394 Route 322, Southington, CT 06410. Attached are a compound plan and elevation depicting the planned changes (Exhibit-1), and documentation of the structural sufficiency of the structure to accommodate the revised antenna configuration (Exhibit-2). Also included is a power density table report reflecting the modification to T-Mobile’s operations at the site (Exhibit-3).
The changes to the facility do not constitute a modification as defined in Connecticut General Statutes (“C.G.S.”) § 16-50i(d) because the general physical characteristics of the facility will not be significantly changed. Rather, the planned changes to the facility fall squarely within those activities explicitly provided for in the R.C.S.A. § 16-50j-72(b)(2).
1. The proposed modifications will not result in an increase in the height of the existingtower. T-Mobile’s replacement antennas will be located at the same elevation on theexisting tower.
2. There will be no proposed modifications to the ground and no extension ofboundaries.
3. The proposed modifications will not increase noise levels at the facility by sixdecibels or more.
Crown Castle 3530 Toringdon Way Suite 300 Charlotte, NC 28277
Tel: 704-405-6600
www.crowncastle.com
Melanie A. Bachman March 26, 2014 Page 2
4. The operation of the replacement antennas will not increase radio frequency (RF)emissions at the facility to a level at or above the Federal CommunicationsCommission (FCC) adopted safety standard. A cumulative General Power Densitytable report for T-Mobile’s modified facility is included as Exhibit-3.
5. A Structural Modification Report confirming that the tower and foundation cansupport Sprint’s proposed modifications is included as Exhibit-2.
For the foregoing reasons, T-Mobile respectfully submits the proposed modifications to the above-reference telecommunications facility constitutes an exempt modification under R.C.S.A. § 16-50j-72(b)(2). Please send approval/rejection letter to Attn: Donna Neal.
Sincerely,
Jeff Barbadora Real Estate Specialist
Enclosure
Tab 1: Exhibit-1: Compound plan and elevation depicting the planned changes Tab 2: Exhibit-2: Structural Modification Report Tab 3: Exhibit-3: General Power Density Table Report (RF Emissions Analysis Report)
cc: Mr. Garry Brumback, Town Manager Town of Southington 75 Main Street Southington, CT 06489
tnxTower Report - version 6.1.4.1
Date: March 11, 2014
Patrick Byrum Paul J Ford and CompanyCrown Castle 250 E. Broad Street, Suite 6003530 Toringdon Way, Suite 300 Columbus, OH 43215Charlotte, NC 28277 614.221.6679704.405.6532 [email protected]
Subject: Structural Analysis Report
Carrier Designation: T-Mobile Co-LocateCarrier Site Number: CT11453CCarrier Site Name: Sounthington - Sprint
Crown Castle Designation: Crown Castle BU Number: 876313Crown Castle Site Name: West Johnson Ave. Burnt HouseCrown Castle JDE Job Number: 260413Crown Castle Work Order Number: 724001Crown Castle Application Number: 217362 Rev. 0
Engineering Firm Designation: Paul J Ford and Company Project Number: 37513-0756 R4
Site Data: 1394 Meriden Waterbury Tpk, SOUTHINGTON, Hartford County, CTLatitude 41° 33' 51.39'', Longitude -72° 53' 30.7''160 Foot - Monopole Tower
Dear Patrick Byrum,
Paul J Ford and Company is pleased to submit this “Structural Analysis Report” to determine the structuralintegrity of the above mentioned tower. This analysis has been performed in accordance with the Crown CastleStructural ‘Statement of Work’ and the terms of Crown Castle Purchase Order Number 624714, in accordancewith application 217362, revision 0.
The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis wehave determined the tower stress level for the structure and foundation, under the following load case, to be:
LC4.7: Modified Structure w/ Existing + Reserved + Proposed Equipment Sufficient CapacityNote: See Table I and Table II for the proposed and existing/reserved loading, respectively.
The structural analysis was performed for this tower in accordance with the requirements of the 2005Connecticut Building Code and the TIA/EIA-222-F Structural Standards for Steel Antenna Towers and AntennaSupporting Structures using a fastest mile wind speed of 80 mph with no ice, 37.6 mph with 1 inch ice thicknessand 50 mph under service loads.
All modifications and equipment proposed in this report shall be installed in accordance with the referenceddrawings for the determined available structural capacity to be effective.
We at Paul J Ford and Company appreciate the opportunity of providing our continuing professional services toyou and Crown Castle. If you have any questions or need further assistance on this or any other projectsplease give us a call.
Respectfully submitted by:
Bob Koors, E.I.Structural Designer
March 11, 2014160 Ft Monopole Tower Structural Analysis CCI BU No 876313Project Number 37513-0756 R4, Application 217362, Revision 0 Page 2
tnxTower Report - version 6.1.4.1
TABLE OF CONTENTS
1) INTRODUCTION
2) ANALYSIS CRITERIATable 1 - Proposed Antenna and Cable InformationTable 2 - Existing and Reserved Antenna and Cable Information
3) ANALYSIS PROCEDURETable 3 - Documents Provided3.1) Analysis Method3.2) Assumptions
4) ANALYSIS RESULTSTable 4 – Section Capacity (Summary)Table 5 - Tower Component Stresses vs. Capacity4.1) Recommendations
5) APPENDIX ATNX Tower Output
6) APPENDIX BBase Level Drawing
7) APPENDIX CAdditional Calculations
March 11, 2014160 Ft Monopole Tower Structural Analysis CCI BU No 876313Project Number 37513-0756 R4, Application 217362, Revision 0 Page 3
tnxTower Report - version 6.1.4.1
1) INTRODUCTION
This tower is a 161 ft Monopole tower designed by SUMMIT in August of 1998.The tower was originally designed for a wind speed of 90 mph per TIA/EIA-222-F.
2) ANALYSIS CRITERIA
The structural analysis was performed for this tower in accordance with the requirements of the 2005Connecticut Building Code and the TIA/EIA-222-F Structural Standards for Steel Antenna Towers and AntennaSupporting Structures using a fastest mile wind speed of 80 mph with no ice, 37.6 mph with 1 inch ice thicknessand 50 mph under service loads.
Table 1 - Proposed Antenna and Cable Information
MountingLevel (ft)
CenterLine
Elevation(ft)
Numberof
AntennasAntenna
Manufacturer Antenna ModelNumberof FeedLines
FeedLine
Size (in)Note
127.0 128.0
3 ericsson ERICSSON AIR 21 B2AB4P w/ Mount Pipe
1 1-5/8 -3 ericsson ERICSSON AIR 21 B4AB2P w/ Mount Pipe
3 ericsson KRY 112 144/1
Table 2 - Existing and Reserved Antenna and Cable Information
MountingLevel (ft)
CenterLine
Elevation(ft)
Numberof
AntennasAntenna
Manufacturer Antenna ModelNumberof FeedLines
FeedLine
Size (in)Note
157.0158.0
3 ericsson RRUS-11 - - 2
1 andrew SBNH-1D6565C w/ MountPipe
612
1-5/83/83/4
1
3 ericsson RRUS-11
3 kathrein 800 10121 w/ Mount Pipe
1 kmwcommunications
AM-X-CD-16-65-00T-RETw/ Mount Pipe
6 powerwavetechnologies LGP21401
1 powerwavetechnologies
P65-17-XLH-RR w/ MountPipe
1 raycap DC6-48-60-18-8F
157.0 1 tower mounts Side Arm Mount [SO 101-3]
148.0 148.0
3 rfs celwave APXVSPP18-C-A20 w/Mount Pipe
3 1-1/4 23 rfs celwave IBC1900BB-13 rfs celwave IBC1900HG-2A1 tower mounts Platform Mount [LP 712-1] - - 1
March 11, 2014160 Ft Monopole Tower Structural Analysis CCI BU No 876313Project Number 37513-0756 R4, Application 217362, Revision 0 Page 4
tnxTower Report - version 6.1.4.1
MountingLevel (ft)
CenterLine
Elevation(ft)
Numberof
AntennasAntenna
Manufacturer Antenna ModelNumberof FeedLines
FeedLine
Size (in)Note
146.0 146.0
3 alcatel lucent 800MHz 2X50W RRHW/FILTER
- - 26 alcatel lucent PCS 1900MHz 4x45W-65MHz
1 tower mounts Side Arm Mount [SO 103-3]
138.0
142.0 1 lucent KS24019-L112A
121
1-5/81/2 1
138.0
3 antel BXA-171063-12BF-EDIN-X w/ Mount Pipe
3 antel BXA-70063-6CF-EDIN-2w/ Mount Pipe
6 antel LPA-80063-6CF-EDIN-2w/ Mount Pipe
6 rfs celwave FD9R6004/2C-3L1 tower mounts Platform Mount [LP 712-1]
127.0128.0
3 andrew ONEBASE TWIN DUALDUPLEX TMA
6 1-5/8 34 ems wireless RR65-19-02DPL5 w/
Mount Pipe6 remec S20057A-1
3 rfs celwave APX16DWV-16DWV-S-E-ACU w/ Mount Pipe
127.0 1 tower mounts Platform Mount [LP 712-1] 12 1-5/8 1
119.0 119.03 andrew HBX-6516DS-VTM w/
Mount Pipe 61
1-5/83/8 1
1 tower mounts T-Arm Mount [TA 602-3]
48.050.0 1 lucent KS24019-L112A
1 1/2 148.0 1 tower mounts Side Arm Mount [SO 701-
1]Notes:1) Existing Equipment2) Reserved Equipment3) Equipment To Be Removed
3) ANALYSIS PROCEDURE
Table 3 - Documents Provided
Document Remarks Reference Source
4-GEOTECHNICAL REPORTS Goodkind & O'Dea, 08/27/1998 1529743 CCISITES4-TOWER FOUNDATION
DRAWINGS/DESIGN/SPECS PJF, 29298-582, 08/27/1998 1633746 CCISITES
4-TOWER MANUFACTURERDRAWINGS PJF, 29298-582, 08/27/1998 2134246 CCISITES
4-TOWER REINFORCEMENTDESIGN/DRAWINGS/DATA GPD, 2012775.876313.01 3348783 CCISITES
FAB DRAWINGS SABRE, 11/13/2013 - PJF
March 11, 2014160 Ft Monopole Tower Structural Analysis CCI BU No 876313Project Number 37513-0756 R4, Application 217362, Revision 0 Page 5
tnxTower Report - version 6.1.4.1
3.1) Analysis Method
tnxTower (version 6.1.4.1), a commercially available analysis software package, was used to create athree-dimensional model of the tower and calculate member stresses for various loading cases.Selected output from the analysis is included in Appendix A.
3.2) Assumptions
1) Monopole was fabricated and installed in accordance with the manufacturer's specifications.2) Monopole has been properly maintained in accordance with manufacturer's specifications.3) The configuration of antennas, transmission cables, mounts and other appurtenances are as
specified in Tables 1 and 2 and the referenced drawings.4) Monopole was modified in conformance with the referenced modification drawings.5) Monopole will be reinforced in conformance with the referenced Sabre fab drawings.
This analysis may be affected if any assumptions are not valid or have been made in error. Paul JFord and Company should be notified to determine the effect on the structural integrity of the tower.
4) ANALYSIS RESULTS
Table 4 - Section Capacity (Summary)Section
No. Elevation (ft) ComponentType Size Critical
Element P (K) SF*P_allow(K)
%Capacity Pass / Fail
L1 160 - 148.5 Pole TP10x10x0.349 1 -1.189 296.209 52.3 Pass
L2 148.5 - 148 Pole TP23x10x0.349 2 -1.192 296.209 52.3 Pass
L3 148 - 111 Pole TP28.994x23x0.25 3 -10.360 1071.395 81.6 Pass
L4 111 - 105.25 Pole TP29.4254x27.8865x0.3125 4 -11.917 1385.720 84.1 Pass
L5 105.25 -76.75 Pole TP34.042x29.4254x0.4446 5 -16.587 2087.545 86.6 Pass
L6 76.75 - 70.75 Pole TP34.3889x32.4643x0.375 6 -19.126 2104.700 99.1 Pass
L7 70.75 - 43 Pole TP38.884x34.3889x0.5356 7 -24.945 2940.038 89.1 Pass
L8 43 - 27.25 Pole TP40.6856x37.0028x0.6528 8 -32.685 3475.731 90.1 Pass
L9 27.25 - 7.375 Pole TP43.9053x40.6856x0.647 9 -39.493 4093.163 85.9 Pass
L10 7.375 - 0 Pole TP45.1x43.9053x0.661 10 -42.184 4578.148 79.9 Pass
Summary
Pole (L6) 99.1 Pass
Rating = 99.1 Pass
March 11, 2014160 Ft Monopole Tower Structural Analysis CCI BU No 876313Project Number 37513-0756 R4, Application 217362, Revision 0 Page 6
tnxTower Report - version 6.1.4.1
Table 5 - Tower Component Stresses vs. Capacity – LC4.7
Notes Component Elevation (ft) % Capacity Pass / Fail
1 Anchor Rods 0 95.7 Pass1 Base Plate 0 86.4 Pass
1 Base FoundationSteel 0 79.1 Pass
1,2 Base FoundationSoil Interaction 0 87.7 Pass
Structure Rating (max from all components) = 99.1%
Notes:1) See additional documentation in “Appendix C – Additional Calculations” for calculations supporting the % capacity
consumed.2) Foundation Analysis Notes: According to the procedures prescribed and agreed to by the Crown Castle Engineering
Foundation Committee, held in January 2010, the existing caisson foundation was analyzed using the methodology inthe software ‘PLS-Caisson’ (Version 8.10, or newer, by Power Line Systems, Inc.). Per the methods in PLS-Caisson,the soil reactions of cohesive soils are calculated using 8CD independent of the depth of the soil layer. The depth ofsoil to be ignored at the top of the caisson is the geotechnical report’s recommendation, or the greater of the frost depthof the site or half of the caisson diameter.
4.1) Recommendations
Reinforce monopole in conformance with the referenced fab drawings.
March 11, 2014160 Ft Monopole Tower Structural Analysis CCI BU No 876313Project Number 37513-0756 R4, Application 217362, Revision 0 Page 7
tnxTower Report - version 6.1.4.1
APPENDIX A
TNXTOWER OUTPUT
March 11, 2014160 Ft Monopole Tower Structural Analysis CCI BU No 876313Project Number 37513-0756 R4, Application 217362, Revision 0 Page 8
tnxTower Report - version 6.1.4.1
Tower Input Data
There is a pole section.This tower is designed using the TIA/EIA-222-F standard.The following design criteria apply:
4) Tower is located in Hartford County, Connecticut.5) Basic wind speed of 80 mph.6) Nominal ice thickness of 1.0000 in.7) Ice thickness is considered to increase with height.8) Ice density of 56.000 pcf.9) A wind speed of 38 mph is used in combination with ice.10) Temperature drop of 50.000 °F.11) Deflections calculated using a wind speed of 50 mph.12) A non-linear (P-delta) analysis was used.13) Pressures are calculated at each section.14) Stress ratio used in pole design is 1.333.15) Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are
not considered.
OptionsConsider Moments - Legs Distribute Leg Loads As Uniform Treat Feedline Bundles As CylinderConsider Moments - Horizontals Assume Legs Pinned Use ASCE 10 X-Brace Ly Rules
Escalate Ice Bypass Mast Stability Checks Offset Girt At Foundation
Include Bolts In Member Capacity Autocalc Torque Arm Areas Poles
Secondary Horizontal Braces Leg Sort Capacity Reports By Component Always Use Sub-Critical FlowUse Diamond Inner Bracing (4 Sided) Triangulate Diamond Inner Bracing Use Top Mounted SocketsAdd IBC .6D+W Combination Use TIA-222-G Tension Splice
Capacity Exemption
Tapered Pole Section GeometrySection Elevation
ft
SectionLength
ft
SpliceLength
ft
Numberof
Sides
TopDiameter
in
BottomDiameter
in
WallThickness
in
BendRadius
in
Pole Grade
L1 160.000-148.500
11.500 0.000 Round 10.0000 10.0000 0.3490 A53-B-35(35 ksi)
L2 148.500-148.000
0.500 0.000 Round 10.0000 23.0000 0.3490 A53-B-35(35 ksi)
L3 148.000-111.000
37.000 3.750 18 23.0000 28.9940 0.2500 1.0000 A607-60(60 ksi)
L4 111.000-105.250
9.500 0.000 18 27.8865 29.4254 0.3125 1.2500 A607-60(60 ksi)
L5 105.250-76.750
28.500 4.250 18 29.4254 34.0420 0.4446 1.7785 Reinf 56.20 ksi(56 ksi)
L6 76.750-70.750 10.250 0.000 18 32.4643 34.3889 0.3750 1.5000 A607-65(65 ksi)
L7 70.750-43.000 27.750 5.000 18 34.3889 38.8840 0.5356 2.1425 Reinf 57.60 ksi(58 ksi)
L8 43.000-27.250 20.750 0.000 18 37.0028 40.6856 0.6528 2.6113 Reinf 52.39 ksi(52 ksi)
L9 27.250-7.375 19.875 0.000 18 40.6856 43.9053 0.6470 2.5880 Reinf 57.61 ksi(58 ksi)
March 11, 2014160 Ft Monopole Tower Structural Analysis CCI BU No 876313Project Number 37513-0756 R4, Application 217362, Revision 0 Page 9
tnxTower Report - version 6.1.4.1
Section Elevation
ft
SectionLength
ft
SpliceLength
ft
Numberof
Sides
TopDiameter
in
BottomDiameter
in
WallThickness
in
BendRadius
in
Pole Grade
L10 7.375-0.000 7.375 18 43.9053 45.1000 0.6610 2.6438 Reinf 61.40 ksi(61 ksi)
Tapered Pole PropertiesSection Tip Dia.
inAreain2
Iin4
rin
Cin
I/Cin3
Jin4
It/Qin2
win
w/t
L1 10.0000 10.5815 123.3587 3.4144 5.0000 24.6717 246.7174 5.2876 0.0000 010.0000 10.5815 123.3587 3.4144 5.0000 24.6717 246.7174 5.2876 0.0000 0
L2 10.0000 10.5815 123.3587 3.4144 5.0000 24.6717 246.7174 5.2876 0.0000 023.0000 24.8349 1593.1275 8.0093 11.5000 138.5328 3186.2550 12.4100 0.0000 0
L3 23.3548 18.0521 1180.3983 8.0762 11.6840 101.0269 2362.3498 9.0278 3.6080 14.43229.4413 22.8084 2380.8169 10.2041 14.7290 161.6420 4764.7665 11.4063 4.6629 18.652
L4 28.9335 27.3500 2627.2035 9.7888 14.1663 185.4539 5257.8639 13.6776 4.3580 13.94629.8793 28.8763 3092.0742 10.3351 14.9481 206.8541 6188.2170 14.4409 4.6289 14.812
L5 29.8793 40.8992 4339.8228 10.2882 14.9481 290.3262 8685.3560 20.4535 4.3963 9.88834.5672 47.4145 6761.7480 11.9271 17.2933 391.0031 13532.393
323.7117 5.2088 11.715
L6 33.7754 38.1943 4968.8541 11.3917 16.4919 301.2913 9944.2464 19.1008 5.0537 13.47734.9194 40.4851 5917.6117 12.0749 17.4696 338.7380 11843.009
920.2464 5.3925 14.38
L7 34.9194 57.5537 8333.2168 12.0179 17.4696 477.0130 16677.3986
28.7823 5.1097 9.54
39.4838 65.1957 12112.9519
13.6137 19.7531 613.2186 24241.8423
32.6040 5.9009 11.017
L8 38.4747 75.3190 12573.3508
12.9042 18.7974 668.8866 25163.2460
37.6667 5.3635 8.216
41.3132 82.9499 16795.1455
14.2116 20.6683 812.6055 33612.3906
41.4828 6.0117 9.209
L9 41.3132 82.2223 16652.6748
14.2137 20.6683 805.7123 33327.2617
41.1190 6.0219 9.307
44.5826 88.8342 21001.7795
15.3567 22.3039 941.6201 42031.1937
44.4256 6.5886 10.183
L10 44.5826 90.7203 21433.8505
15.3517 22.3039 960.9921 42895.9042
45.3688 6.5641 9.931
45.7957 93.2267 23259.8697
15.7759 22.9108 1015.2360 46550.3454
46.6222 6.7743 10.249
TowerElevation
ft
GussetArea
(per face)
ft2
GussetThickness
in
Gusset GradeAdjust. FactorAf
Adjust.Factor
Ar
Weight Mult. Double AngleStitch BoltSpacing
Diagonalsin
Double AngleStitch BoltSpacing
Horizontalsin
L1 160.000-148.500
1 1 1
L2 148.500-148.000
1 1 1
L3 148.000-111.000
1 1 1
L4 111.000-105.250
1 1 1
L5 105.250-76.750
1 1 1
L6 76.750-70.750
1 1 1
L7 70.750-43.000
1 1 1
L8 43.000-27.250
1 1 1
L9 27.250-7.375
1 1 1
L10 7.375-0.000
1 1 1
March 11, 2014160 Ft Monopole Tower Structural Analysis CCI BU No 876313Project Number 37513-0756 R4, Application 217362, Revision 0 Page 10
tnxTower Report - version 6.1.4.1
Feed Line/Linear Appurtenances - Entered As Round Or FlatDescription Face
orLeg
AllowShield
ComponentType
Placement
ft
TotalNumber
NumberPer Row
ClearSpacing
in
Width orDiamete
rin
Perimeter
in
Weight
klf
**
Feed Line/Linear Appurtenances - Entered As AreaDescription Face
orLeg
AllowShield
ComponentType
Placement
ft
TotalNumber
CAAA
ft2/ft
Weight
klfLDF7-50A(1-5/8'') C No Inside Pole 157.000 - 0.000 6 No Ice
1/2'' Ice1'' Ice2'' Ice4'' Ice
0.0000.0000.0000.0000.000
0.0010.0010.0010.0010.001
FB-L98B-002-75000(3/8'')
C No Inside Pole 157.000 - 0.000 1 No Ice1/2'' Ice1'' Ice2'' Ice4'' Ice
0.0000.0000.0000.0000.000
0.0000.0000.0000.0000.000
WR-VG86ST-BRD(3/4)
C No Inside Pole 157.000 - 0.000 2 No Ice1/2'' Ice1'' Ice2'' Ice4'' Ice
0.0000.0000.0000.0000.000
0.0010.0010.0010.0010.001
**HB114-1-08U4-M5J(1
1/4'')C No Inside Pole 148.000 - 0.000 3 No Ice
1/2'' Ice1'' Ice2'' Ice4'' Ice
0.0000.0000.0000.0000.000
0.0010.0010.0010.0010.001
**AL7-50(1 5/8) C No Inside Pole 138.000 - 0.000 12 No Ice
1/2'' Ice1'' Ice2'' Ice4'' Ice
0.0000.0000.0000.0000.000
0.0010.0010.0010.0010.001
LDF4-50A(1/2'') C No Inside Pole 138.000 - 0.000 1 No Ice1/2'' Ice1'' Ice2'' Ice4'' Ice
0.0000.0000.0000.0000.000
0.0000.0000.0000.0000.000
**LDF7-50A(1-5/8'') C No Inside Pole 127.000 - 0.000 7 No Ice
1/2'' Ice1'' Ice2'' Ice4'' Ice
0.0000.0000.0000.0000.000
0.0010.0010.0010.0010.001
LDF7-50A(1-5/8'') C No CaAa (Out OfFace)
127.000 - 0.000 4 No Ice1/2'' Ice1'' Ice2'' Ice4'' Ice
0.0000.0000.0000.0000.000
0.0010.0020.0040.0110.030
LDF7-50A(1-5/8'') C No CaAa (Out OfFace)
127.000 - 0.000 1 No Ice1/2'' Ice1'' Ice2'' Ice4'' Ice
0.1980.2980.3980.5980.998
0.0010.0020.0040.0110.030
MLE Hybrid9Power/18Fiber RL 2(
1 5/8)
C No CaAa (Out OfFace)
127.000 - 0.000 1 No Ice1/2'' Ice1'' Ice2'' Ice4'' Ice
0.0000.0000.0000.0000.000
0.0010.0020.0040.0100.029
March 11, 2014160 Ft Monopole Tower Structural Analysis CCI BU No 876313Project Number 37513-0756 R4, Application 217362, Revision 0 Page 11
tnxTower Report - version 6.1.4.1
Description Faceor
Leg
AllowShield
ComponentType
Placement
ft
TotalNumber
CAAA
ft2/ft
Weight
klf**
FXL-1873( 1 5/8'') C No CaAa (Out OfFace)
119.000 - 0.000 5 No Ice1/2'' Ice1'' Ice2'' Ice4'' Ice
0.0000.0000.0000.0000.000
0.0010.0020.0040.0100.030
860 10033(3/8) C No CaAa (Out OfFace)
119.000 - 0.000 1 No Ice1/2'' Ice1'' Ice2'' Ice4'' Ice
0.0000.0000.0000.0000.000
0.0000.0010.0020.0060.021
**LDF4-50A(1/2'') C No Inside Pole 48.000 - 0.000 1 No Ice
1/2'' Ice1'' Ice2'' Ice4'' Ice
0.0000.0000.0000.0000.000
0.0000.0000.0000.0000.000
**Step Bolts C No CaAa (Out Of
Face)148.000 - 0.000 1 No Ice
1/2'' Ice1'' Ice2'' Ice4'' Ice
0.0620.1630.2630.4630.862
0.0010.0020.0030.0080.024
**1 1/4'' Flat
ReinforcementC No CaAa (Out Of
Face)106.750 - 0.000 1 No Ice
1/2'' Ice1'' Ice2'' Ice4'' Ice
0.2080.3190.4310.6531.097
0.0000.0000.0000.0000.000
**1 1/4'' Flat
ReinforcementC No CaAa (Out Of
Face)49.500 - 24.500 1 No Ice
1/2'' Ice1'' Ice2'' Ice4'' Ice
0.2080.3190.4310.6531.097
0.0000.0000.0000.0000.000
**LDF7-50A(1-5/8'') C No CaAa (Out Of
Face)119.000 - 0.000 1 No Ice
1/2'' Ice1'' Ice2'' Ice4'' Ice
0.1980.2980.3980.5980.998
0.0010.0020.0040.0110.030
**
Feed Line/Linear Appurtenances Section AreasTowerSectio
n
TowerElevation
ft
Face AR
ft2
AF
ft2
CAAAIn Face
ft2
CAAAOut Face
ft2
Weight
KL1 160.000-148.500 A
BC
0.0000.0000.000
0.0000.0000.000
0.0000.0000.000
0.0000.0000.000
0.0000.0000.052
L2 148.500-148.000 ABC
0.0000.0000.000
0.0000.0000.000
0.0000.0000.000
0.0000.0000.000
0.0000.0000.003
L3 148.000-111.000 ABC
0.0000.0000.000
0.0000.0000.000
0.0000.0000.000
0.0000.0007.064
0.0000.0000.777
L4 111.000-105.250 ABC
0.0000.0000.000
0.0000.0000.000
0.0000.0000.000
0.0000.0002.949
0.0000.0000.185
L5 105.250-76.750 ABC
0.0000.0000.000
0.0000.0000.000
0.0000.0000.000
0.0000.00019.005
0.0000.0000.918
L6 76.750-70.750 ABC
0.0000.0000.000
0.0000.0000.000
0.0000.0000.000
0.0000.0004.001
0.0000.0000.193
March 11, 2014160 Ft Monopole Tower Structural Analysis CCI BU No 876313Project Number 37513-0756 R4, Application 217362, Revision 0 Page 12
tnxTower Report - version 6.1.4.1
TowerSectio
n
TowerElevation
ft
Face AR
ft2
AF
ft2
CAAAIn Face
ft2
CAAAOut Face
ft2
Weight
KL7 70.750-43.000 A
BC
0.0000.0000.000
0.0000.0000.000
0.0000.0000.000
0.0000.00019.859
0.0000.0000.894
L8 43.000-27.250 ABC
0.0000.0000.000
0.0000.0000.000
0.0000.0000.000
0.0000.00013.784
0.0000.0000.510
L9 27.250-7.375 ABC
0.0000.0000.000
0.0000.0000.000
0.0000.0000.000
0.0000.00013.826
0.0000.0000.643
L10 7.375-0.000 ABC
0.0000.0000.000
0.0000.0000.000
0.0000.0000.000
0.0000.0004.918
0.0000.0000.239
Feed Line/Linear Appurtenances Section Areas - With IceTowerSectio
n
TowerElevation
ft
Faceor
Leg
IceThickness
in
AR
ft2
AF
ft2
CAAAIn Face
ft2
CAAAOut Face
ft2
Weight
KL1 160.000-148.500 A
BC
1.203 0.0000.0000.000
0.0000.0000.000
0.0000.0000.000
0.0000.0000.000
0.0000.0000.052
L2 148.500-148.000 ABC
1.198 0.0000.0000.000
0.0000.0000.000
0.0000.0000.000
0.0000.0000.000
0.0000.0000.003
L3 148.000-111.000 ABC
1.178 0.0000.0000.000
0.0000.0000.000
0.0000.0000.000
0.0000.00021.433
0.0000.0001.570
L4 111.000-105.250 ABC
1.153 0.0000.0000.000
0.0000.0000.000
0.0000.0000.000
0.0000.0007.405
0.0000.0000.537
L5 105.250-76.750 ABC
1.129 0.0000.0000.000
0.0000.0000.000
0.0000.0000.000
0.0000.00045.460
0.0000.0002.551
L6 76.750-70.750 ABC
1.101 0.0000.0000.000
0.0000.0000.000
0.0000.0000.000
0.0000.0009.570
0.0000.0000.537
L7 70.750-43.000 ABC
1.067 0.0000.0000.000
0.0000.0000.000
0.0000.0000.000
0.0000.00045.742
0.0000.0002.345
L8 43.000-27.250 ABC
1.007 0.0000.0000.000
0.0000.0000.000
0.0000.0000.000
0.0000.00031.334
0.0000.0001.333
L9 27.250-7.375 ABC
1.000 0.0000.0000.000
0.0000.0000.000
0.0000.0000.000
0.0000.00030.779
0.0000.0001.574
L10 7.375-0.000 ABC
1.000 0.0000.0000.000
0.0000.0000.000
0.0000.0000.000
0.0000.00010.982
0.0000.0000.584
Feed Line Center of PressureSection Elevation
ft
CPX
in
CPZ
in
CPXIcein
CPZIcein
L1 160.000-148.500 0.0000 0.0000 0.0000 0.0000L2 148.500-148.000 0.0000 0.0000 0.0000 0.0000L3 148.000-111.000 -0.2392 0.1381 -0.5740 0.3314L4 111.000-105.250 -0.5501 0.3176 -1.0370 0.5987L5 105.250-76.750 -0.6918 0.3994 -1.2376 0.7145L6 76.750-70.750 -0.7005 0.4044 -1.2692 0.7328L7 70.750-43.000 -0.7555 0.4362 -1.3438 0.7759L8 43.000-27.250 -0.8971 0.5179 -1.5550 0.8978
March 11, 2014160 Ft Monopole Tower Structural Analysis CCI BU No 876313Project Number 37513-0756 R4, Application 217362, Revision 0 Page 13
tnxTower Report - version 6.1.4.1
Section Elevation
ft
CPX
in
CPZ
in
CPXIcein
CPZIcein
L9 27.250-7.375 -0.7537 0.4351 -1.3515 0.7803L10 7.375-0.000 -0.7342 0.4239 -1.3373 0.7721
Discrete Tower LoadsDescription Face
orLeg
OffsetType
Offsets:Horz
LateralVert
ftftft
AzimuthAdjustmen
t
°
Placement
ft
CAAAFront
ft2
CAAASide
ft2
Weight
K
Side Arm Mount [SO 101-3]
C None 0.0000 157.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
7.5008.90010.30013.10018.700
7.5008.90010.30013.10018.700
0.2520.3330.4140.5760.900
800 10121 w/ Mount Pipe A From Face 4.0000.0001.000
0.0000 157.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
6.0336.7147.2998.50011.044
4.9486.0226.8108.45912.102
0.0720.1230.1810.3210.728
800 10121 w/ Mount Pipe B From Face 4.0000.0001.000
0.0000 157.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
6.0336.7147.2998.50011.044
4.9486.0226.8108.45912.102
0.0720.1230.1810.3210.728
800 10121 w/ Mount Pipe C From Face 4.0000.0001.000
0.0000 157.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
6.0336.7147.2998.50011.044
4.9486.0226.8108.45912.102
0.0720.1230.1810.3210.728
AM-X-CD-16-65-00T-RETw/ Mount Pipe
A From Face 4.0000.0001.000
0.0000 157.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
8.4989.1499.76711.03113.679
6.3047.4798.36810.17914.024
0.0740.1390.2120.3850.874
DC6-48-60-18-8F B From Face 4.0000.0001.000
0.0000 157.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
2.5672.7983.0383.5434.658
2.5672.7983.0383.5434.658
0.0190.0410.0670.1290.299
P65-17-XLH-RR w/ MountPipe
B From Face 4.0000.0001.000
0.0000 157.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
11.82312.59413.37514.94018.334
9.05610.61912.20514.69719.643
0.0940.1810.2780.5061.144
SBNH-1D6565C w/ MountPipe
C From Face 4.0000.0001.000
0.0000 157.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
11.55612.22312.89314.29117.428
9.71511.18612.59414.86919.618
0.0970.1850.2840.5141.148
(2) LGP21401 A From Face 4.0000.0001.000
0.0000 157.000 No Ice1/2''Ice
1'' Ice2'' Ice
1.2881.4451.6111.9692.788
0.2330.3130.4030.6081.121
0.0140.0210.0300.0550.135
March 11, 2014160 Ft Monopole Tower Structural Analysis CCI BU No 876313Project Number 37513-0756 R4, Application 217362, Revision 0 Page 14
tnxTower Report - version 6.1.4.1
Description Faceor
Leg
OffsetType
Offsets:Horz
LateralVert
ftftft
AzimuthAdjustmen
t
°
Placement
ft
CAAAFront
ft2
CAAASide
ft2
Weight
K
4'' Ice(2) LGP21401 B From Face 4.000
0.0001.000
0.0000 157.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
1.2881.4451.6111.9692.788
0.2330.3130.4030.6081.121
0.0140.0210.0300.0550.135
(2) LGP21401 C From Face 4.0000.0001.000
0.0000 157.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
1.2881.4451.6111.9692.788
0.2330.3130.4030.6081.121
0.0140.0210.0300.0550.135
RRUS-11 A From Face 4.0000.0001.000
0.0000 157.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
3.2493.4913.7414.2685.426
1.3731.5511.7382.1383.042
0.0480.0680.0920.1500.310
RRUS-11 B From Face 4.0000.0001.000
0.0000 157.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
3.2493.4913.7414.2685.426
1.3731.5511.7382.1383.042
0.0480.0680.0920.1500.310
RRUS-11 C From Face 4.0000.0001.000
0.0000 157.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
3.2493.4913.7414.2685.426
1.3731.5511.7382.1383.042
0.0480.0680.0920.1500.310
RRUS-11 A From Face 4.0000.0001.000
0.0000 157.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
3.2493.4913.7414.2685.426
1.3731.5511.7382.1383.042
0.0480.0680.0920.1500.310
RRUS-11 B From Face 4.0000.0001.000
0.0000 157.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
3.2493.4913.7414.2685.426
1.3731.5511.7382.1383.042
0.0480.0680.0920.1500.310
RRUS-11 C From Face 4.0000.0001.000
0.0000 157.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
3.2493.4913.7414.2685.426
1.3731.5511.7382.1383.042
0.0480.0680.0920.1500.310
**Platform Mount [LP 712-1] C None 0.0000 148.000 No Ice
1/2''Ice
1'' Ice2'' Ice4'' Ice
24.53029.94035.35046.17067.810
24.53029.94035.35046.17067.810
1.3351.6461.9562.5773.820
APXVSPP18-C-A20 w/Mount Pipe
A From Face 4.0000.0000.000
0.0000 148.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
8.4989.1499.76711.03113.679
6.9468.1279.02110.84414.851
0.0830.1510.2270.4060.909
APXVSPP18-C-A20 w/Mount Pipe
B From Face 4.0000.0000.000
0.0000 148.000 No Ice1/2''Ice
8.4989.1499.767
6.9468.1279.021
0.0830.1510.227
March 11, 2014160 Ft Monopole Tower Structural Analysis CCI BU No 876313Project Number 37513-0756 R4, Application 217362, Revision 0 Page 15
tnxTower Report - version 6.1.4.1
Description Faceor
Leg
OffsetType
Offsets:Horz
LateralVert
ftftft
AzimuthAdjustmen
t
°
Placement
ft
CAAAFront
ft2
CAAASide
ft2
Weight
K
1'' Ice2'' Ice4'' Ice
11.03113.679
10.84414.851
0.4060.909
APXVSPP18-C-A20 w/Mount Pipe
C From Face 4.0000.0000.000
0.0000 148.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
8.4989.1499.76711.03113.679
6.9468.1279.02110.84414.851
0.0830.1510.2270.4060.909
IBC1900BB-1 A From Face 4.0000.0000.000
0.0000 148.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
1.1271.2731.4271.7612.534
0.5330.6470.7701.0411.688
0.0220.0300.0390.0650.147
IBC1900BB-1 B From Face 4.0000.0000.000
0.0000 148.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
1.1271.2731.4271.7612.534
0.5330.6470.7701.0411.688
0.0220.0300.0390.0650.147
IBC1900BB-1 C From Face 4.0000.0000.000
0.0000 148.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
1.1271.2731.4271.7612.534
0.5330.6470.7701.0411.688
0.0220.0300.0390.0650.147
IBC1900HG-2A A From Face 4.0000.0000.000
0.0000 148.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
1.1271.2731.4271.7612.534
0.5330.6470.7701.0411.688
0.0220.0300.0390.0650.147
IBC1900HG-2A B From Face 4.0000.0000.000
0.0000 148.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
1.1271.2731.4271.7612.534
0.5330.6470.7701.0411.688
0.0220.0300.0390.0650.147
IBC1900HG-2A C From Face 4.0000.0000.000
0.0000 148.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
1.1271.2731.4271.7612.534
0.5330.6470.7701.0411.688
0.0220.0300.0390.0650.147
(2) 2.375'' OD x 6' MountPipe
A From Face 4.0000.0000.000
0.0000 148.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
1.4251.9252.2943.0604.702
1.4251.9252.2943.0604.702
0.0250.0360.0510.0930.234
(2) 2.375'' OD x 6' MountPipe
B From Face 4.0000.0000.000
0.0000 148.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
1.4251.9252.2943.0604.702
1.4251.9252.2943.0604.702
0.0250.0360.0510.0930.234
(2) 2.375'' OD x 6' MountPipe
C From Face 4.0000.0000.000
0.0000 148.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
1.4251.9252.2943.0604.702
1.4251.9252.2943.0604.702
0.0250.0360.0510.0930.234
**Side Arm Mount [SO 103- C None 0.0000 146.000 No Ice 9.500 9.500 0.224
March 11, 2014160 Ft Monopole Tower Structural Analysis CCI BU No 876313Project Number 37513-0756 R4, Application 217362, Revision 0 Page 16
tnxTower Report - version 6.1.4.1
Description Faceor
Leg
OffsetType
Offsets:Horz
LateralVert
ftftft
AzimuthAdjustmen
t
°
Placement
ft
CAAAFront
ft2
CAAASide
ft2
Weight
K
3] 1/2''Ice
1'' Ice2'' Ice4'' Ice
11.80014.10018.70027.900
11.80014.10018.70027.900
0.3170.4100.5960.968
(2) PCS 1900MHz 4x45W-65MHz
A From Face 4.0000.0000.000
0.0000 146.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
2.7092.9483.1953.7164.862
2.6112.8473.0923.6084.744
0.0600.0830.1100.1730.347
(2) PCS 1900MHz 4x45W-65MHz
B From Face 4.0000.0000.000
0.0000 146.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
2.7092.9483.1953.7164.862
2.6112.8473.0923.6084.744
0.0600.0830.1100.1730.347
(2) PCS 1900MHz 4x45W-65MHz
C From Face 4.0000.0000.000
0.0000 146.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
2.7092.9483.1953.7164.862
2.6112.8473.0923.6084.744
0.0600.0830.1100.1730.347
800MHz 2X50W RRHW/FILTER
A From Face 4.0000.0000.000
0.0000 146.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
2.4012.6132.8333.3004.337
2.2542.4602.6753.1324.148
0.0640.0860.1110.1720.338
800MHz 2X50W RRHW/FILTER
B From Face 4.0000.0000.000
0.0000 146.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
2.4012.6132.8333.3004.337
2.2542.4602.6753.1324.148
0.0640.0860.1110.1720.338
800MHz 2X50W RRHW/FILTER
C From Face 4.0000.0000.000
0.0000 146.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
2.4012.6132.8333.3004.337
2.2542.4602.6753.1324.148
0.0640.0860.1110.1720.338
****
Platform Mount [LP 712-1] C None 0.0000 138.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
24.53029.94035.35046.17067.810
24.53029.94035.35046.17067.810
1.3351.6461.9562.5773.820
(2) LPA-80063-6CF-EDIN-2 w/ Mount Pipe
A From Face 4.0000.0000.000
0.0000 138.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
10.74511.41212.04513.34116.054
10.70011.96712.94814.96319.208
0.0520.1450.2470.4801.095
(2) LPA-80063-6CF-EDIN-2 w/ Mount Pipe
B From Face 4.0000.0000.000
0.0000 138.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
10.74511.41212.04513.34116.054
10.70011.96712.94814.96319.208
0.0520.1450.2470.4801.095
(2) LPA-80063-6CF-EDIN-2 w/ Mount Pipe
C From Face 4.0000.0000.000
0.0000 138.000 No Ice1/2''Ice
1'' Ice
10.74511.41212.04513.341
10.70011.96712.94814.963
0.0520.1450.2470.480
March 11, 2014160 Ft Monopole Tower Structural Analysis CCI BU No 876313Project Number 37513-0756 R4, Application 217362, Revision 0 Page 17
tnxTower Report - version 6.1.4.1
Description Faceor
Leg
OffsetType
Offsets:Horz
LateralVert
ftftft
AzimuthAdjustmen
t
°
Placement
ft
CAAAFront
ft2
CAAASide
ft2
Weight
K
2'' Ice4'' Ice
16.054 19.208 1.095
BXA-70063-6CF-EDIN-2w/ Mount Pipe
A From Face 4.0000.0000.000
0.0000 138.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
7.9698.6099.21610.45913.066
5.8016.9537.8199.60113.366
0.0420.1030.1710.3350.804
BXA-70063-6CF-EDIN-2w/ Mount Pipe
B From Face 4.0000.0000.000
0.0000 138.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
7.9698.6099.21610.45913.066
5.8016.9537.8199.60113.366
0.0420.1030.1710.3350.804
BXA-70063-6CF-EDIN-2w/ Mount Pipe
C From Face 4.0000.0000.000
0.0000 138.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
7.9698.6099.21610.45913.066
5.8016.9537.8199.60113.366
0.0420.1030.1710.3350.804
BXA-171063-12BF-EDIN-Xw/ Mount Pipe
A From Face 4.0000.0000.000
0.0000 138.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
5.0375.5926.1137.1779.449
5.2976.4707.3609.16212.966
0.0390.0850.1380.2710.675
BXA-171063-12BF-EDIN-Xw/ Mount Pipe
B From Face 4.0000.0000.000
0.0000 138.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
5.0375.5926.1137.1779.449
5.2976.4707.3609.16212.966
0.0390.0850.1380.2710.675
BXA-171063-12BF-EDIN-Xw/ Mount Pipe
C From Face 4.0000.0000.000
0.0000 138.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
5.0375.5926.1137.1779.449
5.2976.4707.3609.16212.966
0.0390.0850.1380.2710.675
KS24019-L112A C From Face 4.0000.0004.000
0.0000 138.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
0.1560.2250.3020.4840.951
0.1560.2250.3020.4840.951
0.0050.0070.0090.0180.056
(2) FD9R6004/2C-3L A From Face 4.0000.0000.000
0.0000 138.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
0.3670.4510.5430.7551.281
0.0850.1360.1960.3430.740
0.0030.0050.0090.0200.063
(2) FD9R6004/2C-3L B From Face 4.0000.0000.000
0.0000 138.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
0.3670.4510.5430.7551.281
0.0850.1360.1960.3430.740
0.0030.0050.0090.0200.063
(2) FD9R6004/2C-3L C From Face 4.0000.0000.000
0.0000 138.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
0.3670.4510.5430.7551.281
0.0850.1360.1960.3430.740
0.0030.0050.0090.0200.063
**Platform Mount [LP 712-1] C None 0.0000 127.000 No Ice
1/2''24.53029.940
24.53029.940
1.3351.646
March 11, 2014160 Ft Monopole Tower Structural Analysis CCI BU No 876313Project Number 37513-0756 R4, Application 217362, Revision 0 Page 18
tnxTower Report - version 6.1.4.1
Description Faceor
Leg
OffsetType
Offsets:Horz
LateralVert
ftftft
AzimuthAdjustmen
t
°
Placement
ft
CAAAFront
ft2
CAAASide
ft2
Weight
K
Ice1'' Ice2'' Ice4'' Ice
35.35046.17067.810
35.35046.17067.810
1.9562.5773.820
ERICSSON AIR 21 B2AB4P w/ Mount Pipe
A From Face 4.0000.0001.000
0.0000 127.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
6.8257.3477.8638.92611.175
5.6426.4807.2578.86412.293
0.1120.1690.2330.3830.807
ERICSSON AIR 21 B2AB4P w/ Mount Pipe
B From Face 4.0000.0001.000
0.0000 127.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
6.8257.3477.8638.92611.175
5.6426.4807.2578.86412.293
0.1120.1690.2330.3830.807
ERICSSON AIR 21 B2AB4P w/ Mount Pipe
C From Face 4.0000.0001.000
0.0000 127.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
6.8257.3477.8638.92611.175
5.6426.4807.2578.86412.293
0.1120.1690.2330.3830.807
ERICSSON AIR 21 B4AB2P w/ Mount Pipe
A From Face 4.0000.0001.000
0.0000 127.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
6.8157.3377.8538.91611.165
5.6336.4727.2488.85412.280
0.1120.1690.2320.3830.806
ERICSSON AIR 21 B4AB2P w/ Mount Pipe
B From Face 4.0000.0001.000
0.0000 127.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
6.8157.3377.8538.91611.165
5.6336.4727.2488.85412.280
0.1120.1690.2320.3830.806
ERICSSON AIR 21 B4AB2P w/ Mount Pipe
C From Face 4.0000.0001.000
0.0000 127.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
6.8157.3377.8538.91611.165
5.6336.4727.2488.85412.280
0.1120.1690.2320.3830.806
KRY 112 144/1 A From Face 4.0000.0001.000
0.0000 127.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
0.4080.4970.5940.8151.359
0.2040.2730.3510.5330.999
0.0110.0140.0190.0320.082
KRY 112 144/1 B From Face 4.0000.0001.000
0.0000 127.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
0.4080.4970.5940.8151.359
0.2040.2730.3510.5330.999
0.0110.0140.0190.0320.082
KRY 112 144/1 C From Face 4.0000.0001.000
0.0000 127.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
0.4080.4970.5940.8151.359
0.2040.2730.3510.5330.999
0.0110.0140.0190.0320.082
**T-Arm Mount [TA 602-3] C None 0.0000 119.000 No Ice
1/2''Ice
1'' Ice2'' Ice4'' Ice
11.59015.44019.29026.99042.390
11.59015.44019.29026.99042.390
0.7740.9901.2061.6392.503
March 11, 2014160 Ft Monopole Tower Structural Analysis CCI BU No 876313Project Number 37513-0756 R4, Application 217362, Revision 0 Page 19
tnxTower Report - version 6.1.4.1
Description Faceor
Leg
OffsetType
Offsets:Horz
LateralVert
ftftft
AzimuthAdjustmen
t
°
Placement
ft
CAAAFront
ft2
CAAASide
ft2
Weight
K
2.375'' OD x 6' Mount Pipe A From Face 4.0000.0000.000
0.0000 119.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
1.4251.9252.2943.0604.702
1.4251.9252.2943.0604.702
0.0250.0360.0510.0930.234
2.375'' OD x 6' Mount Pipe A From Face 4.0000.0000.000
0.0000 119.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
1.4251.9252.2943.0604.702
1.4251.9252.2943.0604.702
0.0250.0360.0510.0930.234
2.375'' OD x 6' Mount Pipe A From Face 4.0000.0000.000
0.0000 119.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
1.4251.9252.2943.0604.702
1.4251.9252.2943.0604.702
0.0250.0360.0510.0930.234
HBX-6516DS-VTM w/Mount Pipe
A From Face 4.0000.0000.000
0.0000 119.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
3.5983.9984.4355.3687.361
3.2413.9144.5645.9148.877
0.0290.0620.1010.1990.504
HBX-6516DS-VTM w/Mount Pipe
B From Face 4.0000.0000.000
0.0000 119.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
3.5983.9984.4355.3687.361
3.2413.9144.5645.9148.877
0.0290.0620.1010.1990.504
HBX-6516DS-VTM w/Mount Pipe
C From Face 4.0000.0000.000
0.0000 119.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
3.5983.9984.4355.3687.361
3.2413.9144.5645.9148.877
0.0290.0620.1010.1990.504
**KS24019-L112A A From Face 4.000
0.0002.000
0.0000 48.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
0.1560.2250.3020.4840.951
0.1560.2250.3020.4840.951
0.0050.0070.0090.0180.056
Side Arm Mount [SO 701-1]
C None 0.0000 48.000 No Ice1/2''Ice
1'' Ice2'' Ice4'' Ice
0.8501.1401.4302.0103.170
1.6702.3403.0104.3507.030
0.0650.0790.0930.1210.177
**
Tower Pressures - No IceGH = 1.690
SectionElevation
ft
z
ft
KZ qz
ksf
AG
ft2
Face
AF
ft2
AR
ft2
Aleg
ft2
Leg%
CAAAIn
Faceft2
CAAAOut
Faceft2
March 11, 2014160 Ft Monopole Tower Structural Analysis CCI BU No 876313Project Number 37513-0756 R4, Application 217362, Revision 0 Page 20
tnxTower Report - version 6.1.4.1
SectionElevation
ft
z
ft
KZ qz
ksf
AG
ft2
Face
AF
ft2
AR
ft2
Aleg
ft2
Leg%
CAAAIn
Faceft2
CAAAOut
Faceft2
L1 160.000-148.500
154.250 1.554 0.025 9.583 ABC
0.0000.0000.000
9.5839.5839.583
9.583 100.00100.00100.00
0.0000.0000.000
0.0000.0000.000
L2 148.500-148.000
148.217 1.536 0.025 0.688 ABC
0.0000.0000.000
0.6880.6880.688
0.688 100.00100.00100.00
0.0000.0000.000
0.0000.0000.000
L3 148.000-111.000
128.978 1.476 0.024 80.157 ABC
0.0000.0000.000
80.15780.15780.157
80.157 100.00100.00100.00
0.0000.0000.000
0.0000.0007.064
L4 111.000-105.250
108.110 1.404 0.023 13.877 ABC
0.0000.0000.000
13.87713.87713.877
13.877 100.00100.00100.00
0.0000.0000.000
0.0000.0002.949
L5 105.250-76.750
90.654 1.335 0.022 75.368 ABC
0.0000.0000.000
75.36875.36875.368
75.368 100.00100.00100.00
0.0000.0000.000
0.0000.000
19.005L6 76.750-
70.75073.733 1.258 0.021 16.913 A
BC
0.0000.0000.000
16.91316.91316.913
16.913 100.00100.00100.00
0.0000.0000.000
0.0000.0004.001
L7 70.750-43.000
56.591 1.167 0.019 84.722 ABC
0.0000.0000.000
84.72284.72284.722
84.722 100.00100.00100.00
0.0000.0000.000
0.0000.000
19.859L8 43.000-
27.25035.032 1.017 0.017 51.565 A
BC
0.0000.0000.000
51.56551.56551.565
51.565 100.00100.00100.00
0.0000.0000.000
0.0000.000
13.784L9 27.250-
7.37517.186 1 0.016 70.052 A
BC
0.0000.0000.000
70.05270.05270.052
70.052 100.00100.00100.00
0.0000.0000.000
0.0000.000
13.826L10 7.375-
0.0003.671 1 0.016 27.351 A
BC
0.0000.0000.000
27.35127.35127.351
27.351 100.00100.00100.00
0.0000.0000.000
0.0000.0004.918
Tower Pressure - With IceGH = 1.690
SectionElevation
ft
z
ft
KZ qz
ksf
tZ
in
AG
ft2
Face
AF
ft2
AR
ft2
Aleg
ft2
Leg%
CAAAIn
Faceft2
CAAAOut
Faceft2
L1 160.000-148.500
154.250 1.554 0.006 1.2033 11.890 ABC
0.0000.0000.000
11.89011.89011.890
11.890 100.00100.00100.00
0.0000.0000.000
0.0000.0000.000
L2 148.500-148.000
148.217 1.536 0.006 1.1975 0.787 ABC
0.0000.0000.000
0.7870.7870.787
0.787 100.00100.00100.00
0.0000.0000.000
0.0000.0000.000
L3 148.000-111.000
128.978 1.476 0.005 1.1777 87.420 ABC
0.0000.0000.000
87.42087.42087.420
87.420 100.00100.00100.00
0.0000.0000.000
0.0000.000
21.433L4 111.000-
105.250108.110 1.404 0.005 1.1530 15.005 A
BC
0.0000.0000.000
15.00515.00515.005
15.005 100.00100.00100.00
0.0000.0000.000
0.0000.0007.405
L5 105.250-76.750
90.654 1.335 0.005 1.1289 80.730 ABC
0.0000.0000.000
80.73080.73080.730
80.730 100.00100.00100.00
0.0000.0000.000
0.0000.000
45.460L6 76.750-
70.75073.733 1.258 0.005 1.1013 18.042 A
BC
0.0000.0000.000
18.04218.04218.042
18.042 100.00100.00100.00
0.0000.0000.000
0.0000.0009.570
L7 70.750-43.000
56.591 1.167 0.004 1.0669 89.656 ABC
0.0000.0000.000
89.65689.65689.656
89.656 100.00100.00100.00
0.0000.0000.000
0.0000.000
45.742L8 43.000-
27.25035.032 1.017 0.004 1.0072 54.366 A
BC
0.0000.0000.000
54.36654.36654.366
54.366 100.00100.00100.00
0.0000.0000.000
0.0000.000
31.334L9 27.250-
7.37517.186 1 0.004 1.0000 73.364 A
B0.0000.000
73.36473.364
73.364 100.00100.00
0.0000.000
0.0000.000
March 11, 2014160 Ft Monopole Tower Structural Analysis CCI BU No 876313Project Number 37513-0756 R4, Application 217362, Revision 0 Page 21
tnxTower Report - version 6.1.4.1
SectionElevation
ft
z
ft
KZ qz
ksf
tZ
in
AG
ft2
Face
AF
ft2
AR
ft2
Aleg
ft2
Leg%
CAAAIn
Faceft2
CAAAOut
Faceft2
C 0.000 73.364 100.00 0.000 30.779L10 7.375-
0.0003.671 1 0.004 1.0000 28.580 A
BC
0.0000.0000.000
28.58028.58028.580
28.580 100.00100.00100.00
0.0000.0000.000
0.0000.000
10.982
Tower Pressure - ServiceGH = 1.690
SectionElevation
ft
z
ft
KZ qz
ksf
AG
ft2
Face
AF
ft2
AR
ft2
Aleg
ft2
Leg%
CAAAIn
Faceft2
CAAAOut
Faceft2
L1 160.000-148.500
154.250 1.554 0.010 9.583 ABC
0.0000.0000.000
9.5839.5839.583
9.583 100.00100.00100.00
0.0000.0000.000
0.0000.0000.000
L2 148.500-148.000
148.217 1.536 0.010 0.688 ABC
0.0000.0000.000
0.6880.6880.688
0.688 100.00100.00100.00
0.0000.0000.000
0.0000.0000.000
L3 148.000-111.000
128.978 1.476 0.009 80.157 ABC
0.0000.0000.000
80.15780.15780.157
80.157 100.00100.00100.00
0.0000.0000.000
0.0000.0007.064
L4 111.000-105.250
108.110 1.404 0.009 13.877 ABC
0.0000.0000.000
13.87713.87713.877
13.877 100.00100.00100.00
0.0000.0000.000
0.0000.0002.949
L5 105.250-76.750
90.654 1.335 0.009 75.368 ABC
0.0000.0000.000
75.36875.36875.368
75.368 100.00100.00100.00
0.0000.0000.000
0.0000.000
19.005L6 76.750-
70.75073.733 1.258 0.008 16.913 A
BC
0.0000.0000.000
16.91316.91316.913
16.913 100.00100.00100.00
0.0000.0000.000
0.0000.0004.001
L7 70.750-43.000
56.591 1.167 0.007 84.722 ABC
0.0000.0000.000
84.72284.72284.722
84.722 100.00100.00100.00
0.0000.0000.000
0.0000.000
19.859L8 43.000-
27.25035.032 1.017 0.007 51.565 A
BC
0.0000.0000.000
51.56551.56551.565
51.565 100.00100.00100.00
0.0000.0000.000
0.0000.000
13.784L9 27.250-
7.37517.186 1 0.006 70.052 A
BC
0.0000.0000.000
70.05270.05270.052
70.052 100.00100.00100.00
0.0000.0000.000
0.0000.000
13.826L10 7.375-
0.0003.671 1 0.006 27.351 A
BC
0.0000.0000.000
27.35127.35127.351
27.351 100.00100.00100.00
0.0000.0000.000
0.0000.0004.918
Load CombinationsComb.
No.Description
1 Dead Only2 Dead+Wind 0 deg - No Ice3 Dead+Wind 30 deg - No Ice4 Dead+Wind 60 deg - No Ice5 Dead+Wind 90 deg - No Ice6 Dead+Wind 120 deg - No Ice7 Dead+Wind 150 deg - No Ice8 Dead+Wind 180 deg - No Ice9 Dead+Wind 210 deg - No Ice10 Dead+Wind 240 deg - No Ice11 Dead+Wind 270 deg - No Ice12 Dead+Wind 300 deg - No Ice13 Dead+Wind 330 deg - No Ice
March 11, 2014160 Ft Monopole Tower Structural Analysis CCI BU No 876313Project Number 37513-0756 R4, Application 217362, Revision 0 Page 22
tnxTower Report - version 6.1.4.1
Comb.No.
Description
14 Dead+Ice+Temp15 Dead+Wind 0 deg+Ice+Temp16 Dead+Wind 30 deg+Ice+Temp17 Dead+Wind 60 deg+Ice+Temp18 Dead+Wind 90 deg+Ice+Temp19 Dead+Wind 120 deg+Ice+Temp20 Dead+Wind 150 deg+Ice+Temp21 Dead+Wind 180 deg+Ice+Temp22 Dead+Wind 210 deg+Ice+Temp23 Dead+Wind 240 deg+Ice+Temp24 Dead+Wind 270 deg+Ice+Temp25 Dead+Wind 300 deg+Ice+Temp26 Dead+Wind 330 deg+Ice+Temp27 Dead+Wind 0 deg - Service28 Dead+Wind 30 deg - Service29 Dead+Wind 60 deg - Service30 Dead+Wind 90 deg - Service31 Dead+Wind 120 deg - Service32 Dead+Wind 150 deg - Service33 Dead+Wind 180 deg - Service34 Dead+Wind 210 deg - Service35 Dead+Wind 240 deg - Service36 Dead+Wind 270 deg - Service37 Dead+Wind 300 deg - Service38 Dead+Wind 330 deg - Service
Maximum Member ForcesSectio
nNo.
Elevationft
ComponentType
Condition Gov.Load
Comb.
Force
K
Major AxisMoment
kip-ft
Minor AxisMoment
kip-ftL1 160 - 148.5 Pole Max Tension 11 0.000 -0.000 0.000
Max. Compression 14 -3.553 -0.597 -0.025Max. Mx 5 -1.190 -32.779 0.103Max. My 8 -1.193 0.051 -32.383Max. Vy 11 -3.594 32.483 -0.103Max. Vx 8 3.567 0.051 -32.383
Max. Torque 2 -0.881L2 148.5 - 148 Pole Max Tension 1 0.000 0.000 0.000
Max. Compression 14 -3.599 -0.594 -0.027Max. Mx 5 -1.223 -34.580 0.109Max. My 8 -1.227 0.049 -34.170Max. Vy 11 -3.615 34.284 -0.110Max. Vx 8 3.587 0.049 -34.170
Max. Torque 2 -0.881L3 148 - 111 Pole Max Tension 1 0.000 0.000 0.000
Max. Compression 14 -24.117 1.188 -0.199Max. Mx 11 -10.361 498.610 -0.436Max. My 2 -10.368 -0.124 497.097Max. Vy 11 -19.510 498.610 -0.436Max. Vx 8 19.480 0.844 -496.970
Max. Torque 2 -0.881L4 111 - 105.25 Pole Max Tension 1 0.000 0.000 0.000
Max. Compression 14 -26.565 1.782 -0.535Max. Mx 11 -11.918 687.591 -0.591Max. My 2 -11.925 -0.147 685.666Max. Vy 11 -20.273 687.591 -0.591Max. Vx 8 20.243 1.040 -685.634
Max. Torque 6 0.240L5 105.25 -
76.75Pole Max Tension 1 0.000 0.000 0.000
Max. Compression 14 -33.450 3.832 -1.703Max. Mx 11 -16.588 1204.981 -1.039Max. My 8 -16.592 1.626 -1202.178Max. Vy 11 -22.404 1204.981 -1.039Max. Vx 8 22.374 1.626 -1202.178
Max. Torque 6 0.219
March 11, 2014160 Ft Monopole Tower Structural Analysis CCI BU No 876313Project Number 37513-0756 R4, Application 217362, Revision 0 Page 23
tnxTower Report - version 6.1.4.1
Section
No.
Elevationft
ComponentType
Condition Gov.Load
Comb.
Force
K
Major AxisMoment
kip-ft
Minor AxisMoment
kip-ftL6 76.75 -
70.75Pole Max Tension 1 0.000 0.000 0.000
Max. Compression 14 -37.099 4.726 -2.214Max. Mx 11 -19.127 1439.569 -1.232Max. My 8 -19.131 1.879 -1436.406Max. Vy 11 -23.294 1439.569 -1.232Max. Vx 8 23.265 1.879 -1436.406
Max. Torque 15 0.153L7 70.75 - 43 Pole Max Tension 1 0.000 0.000 0.000
Max. Compression 14 -44.849 6.739 -3.368Max. Mx 11 -24.945 1989.583 -1.678Max. My 8 -24.948 2.469 -1985.614Max. Vy 11 -25.058 1989.583 -1.678Max. Vx 8 25.029 2.469 -1985.614
Max. Torque 8 -0.231L8 43 - 27.25 Pole Max Tension 1 0.000 0.000 0.000
Max. Compression 14 -54.681 8.653 -4.417Max. Mx 11 -32.685 2528.320 -2.078Max. My 8 -32.686 3.042 -2523.578Max. Vy 11 -26.699 2528.320 -2.078Max. Vx 8 26.670 3.042 -2523.578
Max. Torque 8 -0.383L9 27.25 -
7.375Pole Max Tension 1 0.000 0.000 0.000
Max. Compression 14 -63.101 10.381 -5.416Max. Mx 11 -39.493 3070.915 -2.484Max. My 8 -39.493 3.588 -3065.471Max. Vy 11 -27.893 3070.915 -2.484Max. Vx 8 27.865 3.588 -3065.471
Max. Torque 8 -0.486L10 7.375 - 0 Pole Max Tension 1 0.000 0.000 0.000
Max. Compression 14 -66.408 11.056 -5.806Max. Mx 11 -42.184 3278.196 -2.637Max. My 8 -42.184 3.793 -3272.493Max. Vy 11 -28.315 3278.196 -2.637Max. Vx 8 28.287 3.793 -3272.493
Max. Torque 8 -0.525
Maximum ReactionsLocation Condition Gov.
LoadComb.
VerticalK
Horizontal, XK
Horizontal, ZK
Pole Max. Vert 14 66.408 -0.001 0.000Max. Hx 11 42.194 28.300 -0.011Max. Hz 2 42.194 -0.011 28.272Max. Mx 2 3270.778 -0.011 28.272Max. Mz 5 3274.178 -28.300 0.011
Max. Torsion 2 0.524 -0.011 28.272Min. Vert 11 42.194 28.300 -0.011Min. Hx 5 42.194 -28.300 0.011Min. Hz 8 42.194 0.011 -28.272Min. Mx 8 -3272.493 0.011 -28.272Min. Mz 11 -3278.196 28.300 -0.011
Min. Torsion 8 -0.525 0.011 -28.272
Tower Mast Reaction SummaryLoad
CombinationVertical
K
Shearx
K
Shearz
K
OverturningMoment, Mx
kip-ft
OverturningMoment, Mz
kip-ft
Torque
kip-ft
March 11, 2014160 Ft Monopole Tower Structural Analysis CCI BU No 876313Project Number 37513-0756 R4, Application 217362, Revision 0 Page 24
tnxTower Report - version 6.1.4.1
LoadCombination
Vertical
K
Shearx
K
Shearz
K
OverturningMoment, Mx
kip-ft
OverturningMoment, Mz
kip-ft
Torque
kip-ftDead Only 42.195 -0.000 0.000 0.834 1.943 0.000Dead+Wind 0 deg - No Ice 42.194 0.011 -28.272 -3270.778 0.240 -0.524Dead+Wind 30 deg - No Ice 42.195 14.162 -24.494 -2833.968 -1637.986 -0.403Dead+Wind 60 deg - No Ice 42.195 24.518 -14.148 -1636.850 -2836.765 -0.175Dead+Wind 90 deg - No Ice 42.194 28.300 -0.011 -0.916 -3274.178 0.100Dead+Wind 120 deg - No Ice 42.195 24.507 14.129 1635.499 -2834.998 0.349Dead+Wind 150 deg - No Ice 42.195 14.143 24.483 2833.921 -1634.913 0.504Dead+Wind 180 deg - No Ice 42.194 -0.011 28.272 3272.493 3.793 0.525Dead+Wind 210 deg - No Ice 42.195 -14.162 24.494 2835.678 1642.014 0.404Dead+Wind 240 deg - No Ice 42.195 -24.518 14.148 1638.563 2840.785 0.175Dead+Wind 270 deg - No Ice 42.194 -28.300 0.011 2.637 3278.196 -0.101Dead+Wind 300 deg - No Ice 42.195 -24.507 -14.129 -1633.773 2839.024 -0.350Dead+Wind 330 deg - No Ice 42.195 -14.143 -24.483 -2832.197 1638.945 -0.505Dead+Ice+Temp 66.408 0.001 -0.000 5.806 11.056 -0.000Dead+Wind 0deg+Ice+Temp
66.408 -0.001 -8.575 -1023.522 11.470 -0.375
Dead+Wind 30deg+Ice+Temp
66.408 4.292 -7.426 -885.537 -504.139 -0.280
Dead+Wind 60deg+Ice+Temp
66.408 7.435 -4.287 -508.642 -881.649 -0.110
Dead+Wind 90deg+Ice+Temp
66.408 8.585 0.001 6.126 -1019.860 0.089
Dead+Wind 120deg+Ice+Temp
66.408 7.436 4.289 520.834 -881.868 0.264
Dead+Wind 150deg+Ice+Temp
66.408 4.294 7.427 897.565 -504.519 0.369
Dead+Wind 180deg+Ice+Temp
66.408 0.001 8.575 1035.328 11.028 0.375
Dead+Wind 210deg+Ice+Temp
66.408 -4.292 7.426 897.342 526.634 0.280
Dead+Wind 240deg+Ice+Temp
66.408 -7.435 4.287 520.448 904.141 0.110
Dead+Wind 270deg+Ice+Temp
66.408 -8.585 -0.001 5.684 1042.351 -0.089
Dead+Wind 300deg+Ice+Temp
66.408 -7.436 -4.289 -509.022 904.364 -0.265
Dead+Wind 330deg+Ice+Temp
66.408 -4.294 -7.427 -885.755 527.018 -0.369
Dead+Wind 0 deg - Service 42.195 0.004 -11.072 -1283.731 1.325 -0.204Dead+Wind 30 deg - Service 42.195 5.546 -9.592 -1112.206 -641.906 -0.157Dead+Wind 60 deg - Service 42.195 9.601 -5.540 -642.150 -1112.562 -0.068Dead+Wind 90 deg - Service 42.195 11.083 -0.004 0.165 -1284.361 0.039Dead+Wind 120 deg -Service
42.195 9.597 5.533 642.667 -1111.866 0.136
Dead+Wind 150 deg -Service
42.195 5.539 9.588 1113.232 -640.701 0.196
Dead+Wind 180 deg -Service
42.195 -0.004 11.072 1285.451 2.716 0.204
Dead+Wind 210 deg -Service
42.195 -5.546 9.592 1113.891 645.926 0.157
Dead+Wind 240 deg -Service
42.195 -9.602 5.541 643.890 1116.636 0.068
Dead+Wind 270 deg -Service
42.195 -11.083 0.004 1.556 1288.399 -0.039
Dead+Wind 300 deg -Service
42.195 -9.597 -5.533 -640.965 1115.941 -0.136
Dead+Wind 330 deg -Service
42.195 -5.539 -9.588 -1111.475 644.722 -0.196
Solution Summary
LoadComb.
Sum of Applied Forces Sum of Reactions% ErrorPX
KPYK
PZK
PXK
PYK
PZK
1 0.000 -42.195 0.000 0.000 42.195 -0.000 0.000%2 0.011 -42.195 -28.277 -0.011 42.194 28.272 0.011%
March 11, 2014160 Ft Monopole Tower Structural Analysis CCI BU No 876313Project Number 37513-0756 R4, Application 217362, Revision 0 Page 25
tnxTower Report - version 6.1.4.1
LoadComb.
Sum of Applied Forces Sum of Reactions% ErrorPX
KPYK
PZK
PXK
PYK
PZK
3 14.162 -42.195 -24.494 -14.162 42.195 24.494 0.000%4 24.518 -42.195 -14.148 -24.518 42.195 14.148 0.000%5 28.305 -42.195 -0.011 -28.300 42.194 0.011 0.011%6 24.508 -42.195 14.129 -24.507 42.195 -14.129 0.000%7 14.143 -42.195 24.484 -14.143 42.195 -24.483 0.000%8 -0.011 -42.195 28.277 0.011 42.194 -28.272 0.011%9 -14.162 -42.195 24.494 14.162 42.195 -24.494 0.000%10 -24.518 -42.195 14.148 24.518 42.195 -14.148 0.000%11 -28.305 -42.195 0.011 28.300 42.194 -0.011 0.011%12 -24.508 -42.195 -14.129 24.507 42.195 14.129 0.000%13 -14.143 -42.195 -24.484 14.143 42.195 24.483 0.000%14 0.000 -66.408 0.000 -0.001 66.408 0.000 0.001%15 -0.001 -66.408 -8.576 0.001 66.408 8.575 0.001%16 4.292 -66.408 -7.426 -4.292 66.408 7.426 0.000%17 7.435 -66.408 -4.287 -7.435 66.408 4.287 0.000%18 8.586 -66.408 0.001 -8.585 66.408 -0.001 0.001%19 7.436 -66.408 4.289 -7.436 66.408 -4.289 0.000%20 4.294 -66.408 7.428 -4.294 66.408 -7.427 0.000%21 0.001 -66.408 8.576 -0.001 66.408 -8.575 0.001%22 -4.292 -66.408 7.426 4.292 66.408 -7.426 0.000%23 -7.435 -66.408 4.287 7.435 66.408 -4.287 0.000%24 -8.586 -66.408 -0.001 8.585 66.408 0.001 0.001%25 -7.436 -66.408 -4.289 7.436 66.408 4.289 0.000%26 -4.294 -66.408 -7.428 4.294 66.408 7.427 0.000%27 0.004 -42.195 -11.074 -0.004 42.195 11.072 0.005%28 5.546 -42.195 -9.593 -5.546 42.195 9.592 0.001%29 9.602 -42.195 -5.541 -9.601 42.195 5.540 0.001%30 11.085 -42.195 -0.004 -11.083 42.195 0.004 0.005%31 9.598 -42.195 5.533 -9.597 42.195 -5.533 0.001%32 5.539 -42.195 9.588 -5.539 42.195 -9.588 0.001%33 -0.004 -42.195 11.074 0.004 42.195 -11.072 0.005%34 -5.546 -42.195 9.593 5.546 42.195 -9.592 0.001%35 -9.602 -42.195 5.541 9.602 42.195 -5.541 0.001%36 -11.085 -42.195 0.004 11.083 42.195 -0.004 0.005%37 -9.598 -42.195 -5.533 9.597 42.195 5.533 0.001%38 -5.539 -42.195 -9.588 5.539 42.195 9.588 0.001%
Non-Linear Convergence ResultsLoad
CombinationConverged? Number
of CyclesDisplacement
ToleranceForce
Tolerance1 Yes 6 0.00000001 0.000000012 Yes 16 0.00010997 0.000137743 Yes 22 0.00000001 0.000133404 Yes 22 0.00000001 0.000132685 Yes 16 0.00010995 0.000104216 Yes 22 0.00000001 0.000132327 Yes 22 0.00000001 0.000133008 Yes 16 0.00010997 0.000130999 Yes 22 0.00000001 0.0001327810 Yes 22 0.00000001 0.0001336811 Yes 16 0.00010993 0.0001049212 Yes 22 0.00000001 0.0001330713 Yes 22 0.00000001 0.0001322014 Yes 11 0.00000001 0.0000407615 Yes 19 0.00000001 0.0001018916 Yes 20 0.00000001 0.0000827317 Yes 20 0.00000001 0.0000828818 Yes 19 0.00000001 0.0001015119 Yes 20 0.00000001 0.0000841620 Yes 20 0.00000001 0.0000837821 Yes 19 0.00000001 0.0001028922 Yes 20 0.00000001 0.0000860823 Yes 20 0.00000001 0.0000860324 Yes 19 0.00000001 0.00010353
March 11, 2014160 Ft Monopole Tower Structural Analysis CCI BU No 876313Project Number 37513-0756 R4, Application 217362, Revision 0 Page 26
tnxTower Report - version 6.1.4.1
25 Yes 20 0.00000001 0.0000848826 Yes 20 0.00000001 0.0000851727 Yes 16 0.00011676 0.0000560928 Yes 19 0.00000001 0.0000802129 Yes 18 0.00000001 0.0001483130 Yes 16 0.00011676 0.0000532331 Yes 18 0.00000001 0.0001480132 Yes 19 0.00000001 0.0000800133 Yes 16 0.00011676 0.0000558734 Yes 18 0.00000001 0.0001488435 Yes 19 0.00000001 0.0000806236 Yes 16 0.00011675 0.0000534137 Yes 19 0.00000001 0.0000800738 Yes 18 0.00000001 0.00014789
Maximum Tower Deflections - Service WindSection
No.Elevation
ft
Horz.Deflection
in
Gov.Load
Comb.
Tilt
°
Twist
°L1 160 - 148.5 47.342 35 2.6948 0.0108L2 148.5 - 148 40.941 35 2.5595 0.0022L3 148 - 111 40.673 35 2.5583 0.0021L4 114.75 - 105.25 24.057 35 2.0900 0.0003L5 105.25 - 76.75 20.053 35 1.9071 0.0003L6 81 - 70.75 11.554 35 1.4264 0.0002L7 70.75 - 43 8.682 35 1.2116 0.0002L8 48 - 27.25 3.968 35 0.7664 0.0001L9 27.25 - 7.375 1.265 35 0.4490 0.0001
L10 7.375 - 0 0.090 35 0.1173 0.0000
Critical Deflections and Radius of Curvature - Service WindElevation
ft
Appurtenance Gov.Load
Comb.
Deflection
in
Tilt
°
Twist
°
Radius ofCurvature
ft157.000 Side Arm Mount [SO 101-3] 35 45.644 2.6468 0.0077 5140148.000 Platform Mount [LP 712-1] 35 40.673 2.5583 0.0022 4441146.000 Side Arm Mount [SO 103-3] 35 39.605 2.5515 0.0020 6916138.000 Platform Mount [LP 712-1] 35 35.384 2.4861 0.0014 6005127.000 Platform Mount [LP 712-1] 35 29.801 2.3221 0.0007 3674119.000 T-Arm Mount [TA 602-3] 35 25.980 2.1727 0.0004 286148.000 KS24019-L112A 35 3.968 0.7664 0.0001 3686
Maximum Tower Deflections - Design WindSection
No.Elevation
ft
Horz.Deflection
in
Gov.Load
Comb.
Tilt
°
Twist
°L1 160 - 148.5 120.059 11 6.8374 0.0274L2 148.5 - 148 103.855 11 6.4931 0.0054L3 148 - 111 103.177 11 6.4901 0.0053L4 114.75 - 105.25 61.079 11 5.3064 0.0007L5 105.25 - 76.75 50.925 11 4.8432 0.0007L6 81 - 70.75 29.360 10 3.6243 0.0006L7 70.75 - 43 22.067 10 3.0794 0.0005L8 48 - 27.25 10.090 10 1.9486 0.0004L9 27.25 - 7.375 3.216 10 1.1420 0.0002
L10 7.375 - 0 0.230 10 0.2983 0.0001
March 11, 2014160 Ft Monopole Tower Structural Analysis CCI BU No 876313Project Number 37513-0756 R4, Application 217362, Revision 0 Page 27
tnxTower Report - version 6.1.4.1
SectionNo.
Elevation
ft
Horz.Deflection
in
Gov.Load
Comb.
Tilt
°
Twist
°
Critical Deflections and Radius of Curvature - Design WindElevation
ft
Appurtenance Gov.Load
Comb.
Deflection
in
Tilt
°
Twist
°
Radius ofCurvature
ft157.000 Side Arm Mount [SO 101-3] 11 115.762 6.7152 0.0197 2112148.000 Platform Mount [LP 712-1] 11 103.177 6.4901 0.0055 1821146.000 Side Arm Mount [SO 103-3] 11 100.472 6.4728 0.0052 2830138.000 Platform Mount [LP 712-1] 11 89.782 6.3076 0.0037 2431127.000 Platform Mount [LP 712-1] 11 75.639 5.8932 0.0017 1479119.000 T-Arm Mount [TA 602-3] 11 65.956 5.5155 0.0010 114948.000 KS24019-L112A 10 10.090 1.9486 0.0004 1454
Compression Checks
Pole Design DataSection
No.Elevation
ft
Size L
ft
Lu
ft
Kl/r Fa
ksi
A
in2
ActualPK
Allow.PaK
RatioPPa
L1 160 - 148.5 (1) TP10x10x0.349 11.500 0.000 0.0 21.000 10.5815 -1.189 222.212 0.005L2 148.5 - 148 (2) TP23x10x0.349 0.500 0.000 0.0 21.000 10.5815 -1.192 222.212 0.005L3 148 - 111 (3) TP28.994x23x0.25 37.000 0.000 0.0 36.000 22.3263 -10.360 803.747 0.013L4 111 - 105.25
(4)TP29.4254x27.8865x0.312
59.500 0.000 0.0 36.000 28.8763 -11.917 1039.550 0.011
L5 105.25 - 76.75(5)
TP34.042x29.4254x0.4446 28.500 0.000 0.0 33.720 46.4429 -16.587 1566.050 0.011
L6 76.75 - 70.75(6)
TP34.3889x32.4643x0.375 10.250 0.000 0.0 39.000 40.4851 -19.126 1578.920 0.012
L7 70.75 - 43 (7) TP38.884x34.3889x0.5356 27.750 0.000 0.0 34.560 63.8187 -24.945 2205.580 0.011L8 43 - 27.25 (8) TP40.6856x37.0028x0.652
820.750 0.000 0.0 31.434 82.9499 -32.685 2607.450 0.013
L9 27.25 - 7.375(9)
TP43.9053x40.6856x0.647 19.875 0.000 0.0 34.566 88.8342 -39.493 3070.640 0.013
L10 7.375 - 0 (10) TP45.1x43.9053x0.661 7.375 0.000 0.0 36.840 93.2267 -42.184 3434.470 0.012
Pole Bending Design DataSection
No.Elevation
ft
Size ActualMx
kip-ft
Actualfbxksi
Allow.Fbxksi
Ratiofbx
Fbx
ActualMy
kip-ft
Actualfbyksi
Allow.Fbyksi
Ratiofby
Fby
L1 160 - 148.5(1)
TP10x10x0.349 32.785 15.946 23.100 0.690 0.000 0.000 23.100 0.000
L2 148.5 - 148(2)
TP23x10x0.349 32.777 15.942 23.100 0.690 0.000 0.000 23.100 0.000
L3 148 - 111 (3) TP28.994x23x0.25 498.750
38.650 36.000 1.074 0.000 0.000 36.000 0.000
L4 111 - 105.25(4)
TP29.4254x27.8865x0.3125
687.808
39.901 36.000 1.108 0.000 0.000 36.000 0.000
L5 105.25 -76.75 (5)
TP34.042x29.4254x0.4446
1205.425
38.569 33.720 1.144 0.000 0.000 33.720 0.000
L6 76.75 - 70.75(6)
TP34.3889x32.4643x0.375
1440.108
51.017 39.000 1.308 0.000 0.000 39.000 0.000
March 11, 2014160 Ft Monopole Tower Structural Analysis CCI BU No 876313Project Number 37513-0756 R4, Application 217362, Revision 0 Page 28
tnxTower Report - version 6.1.4.1
SectionNo.
Elevation
ft
Size ActualMx
kip-ft
Actualfbxksi
Allow.Fbxksi
Ratiofbx
Fbx
ActualMy
kip-ft
Actualfbyksi
Allow.Fbyksi
Ratiofby
Fby
L7 70.75 - 43 (7) TP38.884x34.3889x0.5356
1990.358
40.660 34.560 1.177 0.000 0.000 34.560 0.000
L8 43 - 27.25 (8) TP40.6856x37.0028x0.6528
2529.308
37.351 31.434 1.188 0.000 0.000 31.434 0.000
L9 27.25 - 7.375(9)
TP43.9053x40.6856x0.647
3072.117
39.151 34.566 1.133 0.000 0.000 34.566 0.000
L10 7.375 - 0 (10) TP45.1x43.9053x0.661 3279.475
38.763 36.840 1.052 0.000 0.000 36.840 0.000
Pole Shear Design DataSection
No.Elevation
ft
Size ActualVK
Actualfv
ksi
Allow.Fvksi
RatiofvFv
ActualT
kip-ft
Actualfvtksi
Allow.Fvtksi
Ratiofvt
Fvt
L1 160 - 148.5(1)
TP10x10x0.349 3.599 0.340 14.000 0.049 0.564 0.132 14.000 0.009
L2 148.5 - 148(2)
TP23x10x0.349 3.649 0.345 14.000 0.021 0.564 0.132 14.000 0.009
L3 148 - 111 (3) TP28.994x23x0.25 19.518 0.874 24.000 0.073 0.152 0.006 24.000 0.000L4 111 - 105.25
(4)TP29.4254x27.8865x0.31
2520.283 0.702 24.000 0.059 0.152 0.004 24.000 0.000
L5 105.25 -76.75 (5)
TP34.042x29.4254x0.4446
22.414 0.483 22.480 0.043 0.152 0.002 22.480 0.000
L6 76.75 - 70.75(6)
TP34.3889x32.4643x0.375
23.303 0.576 26.000 0.044 0.151 0.003 26.000 0.000
L7 70.75 - 43 (7) TP38.884x34.3889x0.5356
25.066 0.393 23.040 0.034 0.151 0.001 23.040 0.000
L8 43 - 27.25 (8) TP40.6856x37.0028x0.6528
26.706 0.322 20.956 0.031 0.175 0.001 20.956 0.000
L9 27.25 - 7.375(9)
TP43.9053x40.6856x0.647
27.900 0.314 23.044 0.027 0.175 0.001 23.044 0.000
L10 7.375 - 0 (10) TP45.1x43.9053x0.661 28.323 0.304 24.560 0.025 0.175 0.001 24.560 0.000
Pole Interaction Design DataSection
No.Elevation
ft
RatioPPa
Ratiofbx
Fbx
Ratiofby
Fby
RatiofvFv
Ratiofvt
Fvt
Comb.StressRatio
Allow.StressRatio
Criteria
L1 160 - 148.5(1)
0.005 0.690 0.000 0.049 0.009 0.697 1.333 H1-3+VT
L2 148.5 - 148(2)
0.005 0.690 0.000 0.021 0.009 0.697 1.333 H1-3+VT
L3 148 - 111 (3) 0.013 1.074 0.000 0.073 0.000 1.088 1.333 H1-3+VT
L4 111 - 105.25(4)
0.011 1.108 0.000 0.059 0.000 1.121 1.333 H1-3+VT
L5 105.25 -76.75 (5)
0.011 1.144 0.000 0.043 0.000 1.155 1.333 H1-3+VT
L6 76.75 - 70.75(6)
0.012 1.308 0.000 0.044 0.000 1.321 1.333 H1-3+VT
L7 70.75 - 43 (7) 0.011 1.177 0.000 0.034 0.000 1.188 1.333 H1-3+VT
L8 43 - 27.25 (8) 0.013 1.188 0.000 0.031 0.000 1.201 1.333 H1-3+VT
L9 27.25 - 7.375(9)
0.013 1.133 0.000 0.027 0.000 1.146 1.333 H1-3+VT
March 11, 2014160 Ft Monopole Tower Structural Analysis CCI BU No 876313Project Number 37513-0756 R4, Application 217362, Revision 0 Page 29
tnxTower Report - version 6.1.4.1
SectionNo.
Elevation
ft
RatioPPa
Ratiofbx
Fbx
Ratiofby
Fby
RatiofvFv
Ratiofvt
Fvt
Comb.StressRatio
Allow.StressRatio
Criteria
L10 7.375 - 0 (10) 0.012 1.052 0.000 0.025 0.000 1.065 1.333 H1-3+VT
Section Capacity TableSection
No.Elevation
ftComponent
TypeSize Critical
ElementPK
SF*PallowK
%Capacity
PassFail
L1 160 - 148.5 Pole TP10x10x0.349 1 -1.189 296.209 52.3 PassL2 148.5 - 148 Pole TP23x10x0.349 2 -1.192 296.209 52.3 PassL3 148 - 111 Pole TP28.994x23x0.25 3 -10.360 1071.395 81.6 PassL4 111 - 105.25 Pole TP29.4254x27.8865x0.3125 4 -11.917 1385.720 84.1 PassL5 105.25 - 76.75 Pole TP34.042x29.4254x0.4446 5 -16.587 2087.545 86.6 PassL6 76.75 - 70.75 Pole TP34.3889x32.4643x0.375 6 -19.126 2104.700 99.1 PassL7 70.75 - 43 Pole TP38.884x34.3889x0.5356 7 -24.945 2940.038 89.1 PassL8 43 - 27.25 Pole TP40.6856x37.0028x0.6528 8 -32.685 3475.731 90.1 PassL9 27.25 - 7.375 Pole TP43.9053x40.6856x0.647 9 -39.493 4093.163 85.9 PassL10 7.375 - 0 Pole TP45.1x43.9053x0.661 10 -42.184 4578.148 79.9 Pass
SummaryPole (L6) 99.1 Pass
RATING = 99.1 Pass
March 11, 2014160 Ft Monopole Tower Structural Analysis CCI BU No 876313Project Number 37513-0756 R4, Application 217362, Revision 0 Page 30
tnxTower Report - version 6.1.4.1
APPENDIX B
BASE LEVEL DRAWING
March 11, 2014160 Ft Monopole Tower Structural Analysis CCI BU No 876313Project Number 37513-0756 R4, Application 217362, Revision 0 Page 31
tnxTower Report - version 6.1.4.1
March 11, 2014160 Ft Monopole Tower Structural Analysis CCI BU No 876313Project Number 37513-0756 R4, Application 217362, Revision 0 Page 32
tnxTower Report - version 6.1.4.1
APPENDIX C
ADDITIONAL CALCULATIONS
Paul J Ford and Company250 E. Broad Street, Suite 600
Columbus, OH 43215Phone: 614.221.6679FAX: 614.448.4105
Job: 160' Monopole / Burnt HouseProject: PJF 37513-0756 / BU 876313Client: Crown Castle Drawn by: John J Woolley App'd:
Code: TIA/EIA-222-F Date: 03/11/14 Scale: NTSPath:
G:\TOWER\375_Crown_Castle\2013\37513-0756 BU 876313\WO 724001 BU 876313 - (7809)\37513-0756 R4_SABRE Reinforced.eriDwg No. E-1
160.0 ft
148.5 ft
111.0 ft
105.3 ft
76.8 ft
70.8 ft
43.0 ft
27.3 ft
7.4 ft
0.0 ft
REACTIONS - 80 mph WINDTORQUE 1 kip-ft
28 KSHEAR
3279 kip-ftMOMENT
42 KAXIAL
38 mph WIND - 1.0000 in ICETORQUE 0 kip-ft
9 KSHEAR
1043 kip-ftMOMENT
66 KAXIAL
Sec
tion
12
34
56
78
910
Leng
th(ft
)11
.500
0.50
037
.000
9.50
028
.500
10.2
5027
.750
20.7
5019
.875
7.37
5
Num
bero
fSid
es1
118
1818
1818
1818
18
Thic
knes
s(in
)0.
3490
0.34
900.
2500
0.31
250.
4446
0.37
500.
5356
0.65
280.
6470
0.66
10
Soc
ketL
engt
h(ft
)3.
750
4.25
05.
000
Top
Dia
(in)
10.0
000
10.0
000
23.0
000
27.8
865
29.4
254
32.4
643
34.3
889
37.0
028
40.6
856
43.9
053
Bot
Dia
(in)
10.0
000
23.0
000
28.9
940
29.4
254
34.0
420
34.3
889
38.8
840
40.6
856
43.9
053
45.1
000
Gra
deA
53-B
-35
A60
7-60
Rei
nf56
.20
ksi
A60
7-65
Rei
nf57
.60
ksi
Rei
nf52
.39
ksi
Rei
nf57
.61
ksi
Rei
nf61
.40
ksi
Wei
ght(
K)
0.4
0.0
2.6
0.9
4.3
1.4
5.8
5.6
5.8
2.3
29.1
Side Arm Mount [SO 101-3] 157800 10121 w/ Mount Pipe 157800 10121 w/ Mount Pipe 157800 10121 w/ Mount Pipe 157AM-X-CD-16-65-00T-RET w/ MountPipe
157DC6-48-60-18-8F 157P65-17-XLH-RR w/ Mount Pipe 157SBNH-1D6565C w/ Mount Pipe 157(2) LGP21401 157(2) LGP21401 157(2) LGP21401 157RRUS-11 157RRUS-11 157RRUS-11 157RRUS-11 157RRUS-11 157RRUS-11 157Platform Mount [LP 712-1] 148APXVSPP18-C-A20 w/ Mount Pipe 148APXVSPP18-C-A20 w/ Mount Pipe 148APXVSPP18-C-A20 w/ Mount Pipe 148IBC1900BB-1 148IBC1900BB-1 148IBC1900BB-1 148IBC1900HG-2A 148IBC1900HG-2A 148IBC1900HG-2A 148(2) 2.375" OD x 6' Mount Pipe 148(2) 2.375" OD x 6' Mount Pipe 148(2) 2.375" OD x 6' Mount Pipe 148Side Arm Mount [SO 103-3] 146(2) PCS 1900MHz 4x45W-65MHz 146(2) PCS 1900MHz 4x45W-65MHz 146(2) PCS 1900MHz 4x45W-65MHz 146800MHz 2X50W RRH W/FILTER 146800MHz 2X50W RRH W/FILTER 146800MHz 2X50W RRH W/FILTER 146Platform Mount [LP 712-1] 138(2) LPA-80063-6CF-EDIN-2 w/ MountPipe
138(2) LPA-80063-6CF-EDIN-2 w/ MountPipe
138(2) LPA-80063-6CF-EDIN-2 w/ MountPipe
138BXA-70063-6CF-EDIN-2 w/ MountPipe
138BXA-70063-6CF-EDIN-2 w/ MountPipe
138BXA-70063-6CF-EDIN-2 w/ MountPipe
138BXA-171063-12BF-EDIN-X w/ MountPipe
138BXA-171063-12BF-EDIN-X w/ MountPipe
138BXA-171063-12BF-EDIN-X w/ MountPipe
138KS24019-L112A 138(2) FD9R6004/2C-3L 138(2) FD9R6004/2C-3L 138(2) FD9R6004/2C-3L 138Platform Mount [LP 712-1] 127ERICSSON AIR 21 B2A B4P w/ MountPipe
127ERICSSON AIR 21 B2A B4P w/ MountPipe
127ERICSSON AIR 21 B2A B4P w/ MountPipe
127ERICSSON AIR 21 B4A B2P w/ MountPipe
127ERICSSON AIR 21 B4A B2P w/ MountPipe
127ERICSSON AIR 21 B4A B2P w/ MountPipe
127KRY 112 144/1 127KRY 112 144/1 127KRY 112 144/1 127T-Arm Mount [TA 602-3] 1192.375" OD x 6' Mount Pipe 1192.375" OD x 6' Mount Pipe 1192.375" OD x 6' Mount Pipe 119HBX-6516DS-VTM w/ Mount Pipe 119HBX-6516DS-VTM w/ Mount Pipe 119HBX-6516DS-VTM w/ Mount Pipe 119KS24019-L112A 48Side Arm Mount [SO 701-1] 48DESIGNED APPURTENANCE LOADINGTYPE TYPEELEVATION ELEVATION
Side Arm Mount [SO 101-3] 157800 10121 w/ Mount Pipe 157800 10121 w/ Mount Pipe 157800 10121 w/ Mount Pipe 157AM-X-CD-16-65-00T-RET w/ MountPipe
157
DC6-48-60-18-8F 157P65-17-XLH-RR w/ Mount Pipe 157SBNH-1D6565C w/ Mount Pipe 157(2) LGP21401 157(2) LGP21401 157(2) LGP21401 157RRUS-11 157RRUS-11 157RRUS-11 157RRUS-11 157RRUS-11 157RRUS-11 157Platform Mount [LP 712-1] 148APXVSPP18-C-A20 w/ Mount Pipe 148APXVSPP18-C-A20 w/ Mount Pipe 148APXVSPP18-C-A20 w/ Mount Pipe 148IBC1900BB-1 148IBC1900BB-1 148IBC1900BB-1 148IBC1900HG-2A 148IBC1900HG-2A 148IBC1900HG-2A 148(2) 2.375" OD x 6' Mount Pipe 148(2) 2.375" OD x 6' Mount Pipe 148(2) 2.375" OD x 6' Mount Pipe 148Side Arm Mount [SO 103-3] 146(2) PCS 1900MHz 4x45W-65MHz 146(2) PCS 1900MHz 4x45W-65MHz 146(2) PCS 1900MHz 4x45W-65MHz 146800MHz 2X50W RRH W/FILTER 146800MHz 2X50W RRH W/FILTER 146800MHz 2X50W RRH W/FILTER 146Platform Mount [LP 712-1] 138(2) LPA-80063-6CF-EDIN-2 w/ MountPipe
138
(2) LPA-80063-6CF-EDIN-2 w/ MountPipe
138
(2) LPA-80063-6CF-EDIN-2 w/ MountPipe
138
BXA-70063-6CF-EDIN-2 w/ MountPipe
138
BXA-70063-6CF-EDIN-2 w/ MountPipe
138
BXA-70063-6CF-EDIN-2 w/ MountPipe
138
BXA-171063-12BF-EDIN-X w/ MountPipe
138
BXA-171063-12BF-EDIN-X w/ MountPipe
138
BXA-171063-12BF-EDIN-X w/ MountPipe
138
KS24019-L112A 138(2) FD9R6004/2C-3L 138(2) FD9R6004/2C-3L 138(2) FD9R6004/2C-3L 138Platform Mount [LP 712-1] 127ERICSSON AIR 21 B2A B4P w/ MountPipe
127
ERICSSON AIR 21 B2A B4P w/ MountPipe
127
ERICSSON AIR 21 B2A B4P w/ MountPipe
127
ERICSSON AIR 21 B4A B2P w/ MountPipe
127
ERICSSON AIR 21 B4A B2P w/ MountPipe
127
ERICSSON AIR 21 B4A B2P w/ MountPipe
127
KRY 112 144/1 127KRY 112 144/1 127KRY 112 144/1 127T-Arm Mount [TA 602-3] 1192.375" OD x 6' Mount Pipe 1192.375" OD x 6' Mount Pipe 1192.375" OD x 6' Mount Pipe 119HBX-6516DS-VTM w/ Mount Pipe 119HBX-6516DS-VTM w/ Mount Pipe 119HBX-6516DS-VTM w/ Mount Pipe 119KS24019-L112A 48Side Arm Mount [SO 701-1] 48
MATERIAL STRENGTHGRADE GRADEFy FyFu Fu
A53-B-35 35 ksi 58 ksiA607-60 60 ksi 75 ksiReinf 56.20 ksi 56 ksi 71 ksiA607-65 65 ksi 80 ksi
Reinf 57.60 ksi 58 ksi 72 ksiReinf 52.39 ksi 52 ksi 66 ksiReinf 57.61 ksi 58 ksi 65 ksiReinf 61.40 ksi 61 ksi 77 ksi
TOWER DESIGN NOTES1. Tower is located in Hartford County, Connecticut.2. Tower designed for a 80 mph basic wind in accordance with the TIA/EIA-222-F Standard.3. Tower is also designed for a 38 mph basic wind with 1.00 in ice. Ice is considered to
increase in thickness with height.4. Deflections are based upon a 50 mph wind.5. TOWER RATING: 99.1%
Assumptions: 1) Rod groups at corners. Total # rods divisible by 4. Maximum total # of rods = 48 (12 per Corner).2) Rod Spacing = Straight Center-to-Center distance between any (2) adjacent rods (same corner)
Site DataBU#: F
Site Name: 3279 ft-kipsApp #: 42 kips
28 kipsQty: 16
Diam: 2.25 in Anchor Rod ResultsRod Material: A615-J TIA F --> Maximum Rod Tension 186.5 Kips
Yield, Fy: 75 ksi Allowable Tension: 195.0 KipsStrength, Fu: 100 ksi Anchor Rod Stress Ratio: 95.7% Pass
Bolt Circle: 52 inAnchor Spacing: 6 in
Base Plate Results Flexural Check PL Ref. DataW=Side: 53 in Base Plate Stress: 43.2 ksi Yield Line (in):
Thick: 3 in Allowable PL Bending Stress: 50.0 ksi 29.85Grade: 50 ksi Base Plate Stress Ratio: 86.4% Pass Max PL Length:
Clip Distance: 0 in 29.85N/A - UnstiffenedStiffener Results
Configuration: Unstiffened Horizontal Weld : N/AWeld Type: ** Vertical Weld: N/A
Groove Depth: in ** Plate Flex+Shear, fb/Fb+(fv/Fv)^2: N/AGroove Angle: degrees Plate Tension+Shear, ft/Ft+(fv/Fv)^2: N/AFillet H. Weld: <-- Disregard Plate Comp. (AISC Bracket): N/AFillet V. Weld: in Pole Results
Width: in Pole Punching Shear Check: N/AHeight: inThick: inNotch: inGrade: ksi
Weld str.: ksi
Pole DataDiam: 45.1 inThick: 0.4375 in
Grade: 65 ksi# of Sides: 18 "0" IF Round
ASD ASIF: 1.333** Note: for complete joint penetration groove welds the groove depth must be exactly 1/2 the stiffener thickness for calculation purposes
Square, Stiffened / Unstiffened Base Plate, Any Rod Material - Rev. F /G
876313
Unfactored Axial, P:
3) Clear space between bottom of leveling nut and top of concrete not exceeding (1)*(Rod Diameter)
Unfactored Moment, M:TIA Revision:
Base Reactions
Stress Increase Factor
Plate Data
Stiffener Data (Welding at both sides)
Anchor Rod Data Unfactored Shear, V:
CCIplate 1.5 - Square Base F-G 1.2, Effective March 19, 2012 Analysis date: 3/11/2014
PJF job no. 37513-0756 R4 Project name 160' Monopole Page 1
foundation loads Overturning Moment = 363 ft-kTower or Pole Weight = kipsTotal Horizontal Force = kips
Overturning Moment = ft-kipsHoriz Load = 0 k
soil propertiesSafety factor against overturning =
Soil density = pcfAllowable soil bearing = ksf
Depth to water table = ft
mat dimensionsdepth to bottom of footing = ft
Footing thickness = ft 2.628 ksfFooting Width = ft
Footing Length = ftTower/Pole Center Offset = ft
Volume of concrete = yd3 Concrete strength = f'c = (ksi)Rebar = ( 44 ) #9 bars by 10.5 ft long
reinforcing steel = ( 11 ) #9 @ 12.6 in o.c. ea way top and bottom
Summary of analysis results
Overturning Moment: (Stress Ratio = 0.779 ) Rebar strength = Fy = (ksi)Calculated Overturning Moment = 363 ft-kips minimum cover over rebar = inches
Resisting Moment = 698.8 ft-kipsFactor of Safety against overturning = > 1.5 okay
Soil Bearing (Stress Ratio = 0.876 ) < CONTROLLING CRITERIANet Soil Bearing Resistance = 3 ksf
Calculated Soil Bearing Pressure = 2.628 ksf < 3 ksf okay
Bending Moment (Stress Ratio = 0.059 )Ultimate Bending Moment Resistance = 3890 ft-kips
Calculated Ultimate Bending Moment = 228 ft-kips < 3890 ft-kips okay
Bending Shear (Stress Ratio = 0.06 )Ultimate Bending Shear Resistance = 1126 kips
Calculated Ultimate Bending Shear = 68 kips < 1126 kips okay
127.05 k conc
3
31.37
11 ft x 11 ft
eccentricity = 2.857 ft127.05 k
00
7ft
6.5
ft
0 ft
0.5 ftwater tablebelow ftg
76.5
4
60
01111
31151.5
363Wt = 0 k
7
1.925
Job Number: 37513-0756 R4 Page: 1Site Number: 876313 By: RMKSite Name: Site Name Date: 3/11/2014
Unfactored Base Reactions from RISAComp. (+) Tension (-) Tower Type = Monopole DP
Moment, M = 2916.0 k-ft ACI Code = ACI 318-02Shear, V = 28.0 kips Seismic Design Category = DAxial Load, P = 42.0 kips Reference Standard = TIA/EIA-222-FAxial Load, P = 42.0 0.0 kips Use 1.3 Load Factor? YesOTM = 2930.0 0.0 k-ft @ Ground Load Factor = 1.30*Axial Load, Pu1 will be used for Soil Compression Analysis.**Axial Load, Pu2 will be used for Steel Analysis.Drilled Pier Parameters Safety FactorDiameter = 7 ft Soil Lateral Resistance = 2.00 0.75Height Above Grade = 0.5 ft Skin Friction = 2.00 0.75Depth Below Grade = 25.5 ft End Bearing = 2.00 0.75fc' = 3 ksi Concrete Wt. Resist Uplift = 1.25
Load Combinations Checked per TIA/EIA-222-FMat Ftdn. Cap Width = 11 ft 1. Ult. Skin Friction/2.00 + Ult. End Bearing/2.00
Steel Parameters Soil ParametersNumber of Bars = 20 Water Table Depth = 7.00 ftRebar Size = #11 Depth to Ignore Soil = 3.50 ftRebar Fy = 60 ksi Depth to Full Cohesion = 0 ftRebar MOE = 29000 ksi Full Cohesion Starts at? GroundTie Size = #5 Above Full Cohesion Lateral Resistance = 4(Cohesion)(Dia)(H)Side Clear Cover to Ties = 4 in Below Full Cohesion Lateral Resistance = 8(Cohesion)(Dia)(H)
Direct Embed Pole Shaft Parameters Maximum Capacity RatiosDia @ Grade = in Maximum Soil Ratio = 100.0%Dia @ Depth Below Grade = in Maximum Steel Ratio = 100.0%Number of Sides =Thickness = inFy = ksiBackfill Condition =
Define Soil LayersNote: Cohesion = Undrained Shear Strengh = Unconfined Compressive Strength / 2
Friction Ultimate Comp. Ult. Tension Ult.Thickness Unit Weight Cohesion Angle End Bearing Skin Friction Skin Friction Depth
Layer ft pcf psf degrees Soil Type psf psf psf ft1 2 110 26 Sand 22 3 120 33 Sand 53 32 115 25 Sand 6000 37456789
101112
Soil Results: OverturningDepth to COR = 17.08 ft, from Grade Shear, V = 28.00 kipsBending Moment, M = 3408.19 k-ft, from COR Resisting Shear, Va = 31.93 kipsResisting Moment, Ma = 3885.99 k-ft, from COR
Soil Results: Uplift Soil Results: CompressionUplift, T = 0.00 kips Compression, C = 42.00 kipsAllowable Uplift Cap., Ta = 153.84 kips Allowable Comp. Cap., Ca = 301.41 kips
Steel Results (ACI 318-02):Minimum Steel Area = 18.47 sq in Axial Load, P = 36.31 kips @ 6.50 ft Below GradeActual Steel Area = 31.20 sq in Moment, M = 3006.91 k-ft @ 6.50 ft Below Grade
Allowable Moment, Ma = 3801.44 k-ftAllowable Min Axial, Pa = -1296.00 kips, Where Ma = 0 k-ftAllowable Max Axial, Pa = 6369.58 kips, Where Ma = 0 k-ft
COMPRESSION RATIO = 13.9%
MOMENT RATIO = 79.1% OK
DRILLED PIER SOIL AND STEEL ANALYSIS - TIA/EIA-222-F
SHEAR RATIO = 87.7% OKMOMENT RATIO = 87.7% OK
OKUPLIFT RATIO = 0.0% OK
v4.0 - Effective: 10-18-13 (c) Copyright 2013 by Paul J. Ford and Company, all rights reserved.
Site DataBU#: F
Site Name: 3006.91 ft-kips (* Note)App #: 36.31 kips
Comp.
For M (WL) 1.3 <---- Enter FactorFor P (DL) 1.3 <---- Enter Factor Load Factor
1.30 Mu: 3908.983 ft-kips1.30 Pu: 47.203 kips
Concrete:7.0 ft
5541.8 in2 3000 psi60 ksi
Reinforcement: 29000 ksi4.00 in 0.00207
Horiz. Tie Bar Size= 5 0.0036.11 ft73.34 in 2002
111.41 in D1.56 in2 Seismic Risk = High20
As Total= 31.2 in2 Solve <-- Press Upon Completing All InputA s/ Aconc, Rho: 0.0056 0.56% (Run)
ACI 10.5 , ACI 21.10.4, and IBC 1810. Results:Min As for Flexural, Tension Controlled, Shafts: Governing Orientation Case: 1
(3)*(Sqrt(f'c)/Fy: 0.0027200 / Fy: 0.0033
Dist. From Edge to Neutral Axis: 13.64 inExtreme Steel Strain, 0.0143
Minimum Rho Check:Actual Req'd Min. Rho: 0.33% Flexural 0.900
Provided Rho: 0.56% OK
Ref. Shaft Max Axial Capacities, Max(Pn or Tn):Output Note: Negative Pu=Tension
4941.85 ft-kipsDrilled Shaft Superimposed Mu: 3908.98 ft-kips
1684.8 kips0.00 ft-kips 79.1%
Case 1 Case 2
Limiting compressive strain =
Vertical Bar Size = Seismic PropertiesBar Diameter =
Material Properties
Number of Bars =
Vert. Cage Diameter =
at Mu= Mn=
at Mu=( Mn=Pn per ACI 318 (10-2)
Seismic Design Category =
Vert. Cage Diameter =
Enter Load Factors Below:
Shaft Factored Loads
Bar Area =
Pier Properties
Pier Diameter =Concrete Comp. strength, f'c =Reinforcement yield strength, Fy =
Concrete Area =
Moment Capacity of Drilled Concrete Shaft (Caisson) for TIA Rev F or G
TIA Revision:Max. Service Shaft M:Max. Service Shaft P:
Maximum Shaft Superimposed Forces
Max Axial Force Type:
ACI 318 CodeSelect Analysis ACI Code=
Note: Shaft assumed to have ties, not spiral, transverse reinforcing
Reinforcing Modulus of Elasticity, E =Reinforcement yield strain =
876313Site Name
(*) Note: Max Shaft Superimposed Moment does not necessarilyequal to the shaft top reaction moment
Clear Cover to Tie=
Mu Mu
EQ EQ
Drilled_Shaft_Moment_Capacity, DSMC, Version 1.1 - Effective 04/01/ 2010 Analysis Date: 3/11/2014
EBI Consulting environmental | engineering | due diligence
21 B Street .
Burlington, MA 01803 .
Tel: (781) 273.2500 .
Fax: (781) 273.3311
RADIO FREQUENCY EMISSIONS ANALYSIS REPORT EVALUATION OF HUMAN EXPOSURE POTENTIAL
TO NON-IONIZING EMISSIONS
T-Mobile Existing Facility
Site ID: CT11453C
Southington (Sprint)
1394 Route 322 Southington, CT 06410
March 21, 2014
EBI Project Number: 62141636
EBI Consulting environmental | engineering | due diligence
21 B Street .
Burlington, MA 01803 .
Tel: (781) 273.2500 .
Fax: (781) 273.3311
March 21, 2014
T-Mobile USA
Attn: Jason Overbey, RF Manager
35 Griffin Road South
Bloomfield, CT 06002
Re: Emissions Values for Site: CT11453C - Southington (Sprint)
EBI Consulting was directed to analyze the proposed T-Mobile facility located at 1394 Route 322,
Southington, CT, for the purpose of determining whether the emissions from the Proposed T-Mobile
Antenna Installation located on this property are within specified federal limits.
All information used in this report was analyzed as a percentage of current Maximum Permissible
Exposure (% MPE) as listed in the FCC OET Bulletin 65 Edition 97-01and ANSI/IEEE Std C95.1. The
FCC regulates Maximum Permissible Exposure in units of microwatts per square centimeter (µW/cm2).
The number of µW/cm2 calculated at each sample point is called the power density. The exposure limit
for power density varies depending upon the frequencies being utilized. Wireless Carriers and Paging
Services use different frequency bands each with different exposure limits, therefore it is necessary to
report results and limits in terms of percent MPE rather than power density.
All results were compared to the FCC (Federal Communications Commission) radio frequency exposure
rules, 47 CFR 1.1307(b)(1) – (b)(3), to determine compliance with the Maximum Permissible Exposure
(MPE) limits for General Population/Uncontrolled environments as defined below.
General population/uncontrolled exposure limits apply to situations in which the general public may be
exposed or in which persons who are exposed as a consequence of their employment may not be made
fully aware of the potential for exposure or cannot exercise control over their exposure. Therefore,
members of the general public would always be considered under this category when exposure is not
employment related, for example, in the case of a telecommunications tower that exposes persons in a
nearby residential area.
Public exposure to radio frequencies is regulated and enforced in units of microwatts per square
centimeter (µW/cm2). The general population exposure limit for the cellular band is 567 µW/cm2, and the
general population exposure limit for the PCS band is 1000 µW/cm2. Because each carrier will be using
different frequency bands, and each frequency band has different exposure limits, it is necessary to report
percent of MPE rather than power density.
EBI Consulting environmental | engineering | due diligence
21 B Street .
Burlington, MA 01803 .
Tel: (781) 273.2500 .
Fax: (781) 273.3311
Occupational/controlled exposure limits apply to situations in which persons are exposed as a
consequence of their employment and in which those persons who are exposed have been made fully
aware of the potential for exposure and can exercise control over their exposure. Occupational/controlled
exposure limits also apply where exposure is of a transient nature as a result of incidental passage through
a location where exposure levels may be above general population/uncontrolled limits (see below), as
long as the exposed person has been made fully aware of the potential for exposure and can exercise
control over his or her exposure by leaving the area or by some other appropriate means.
Additional details can be found in FCC OET 65.
CALCULATIONS
Calculations were done for the proposed T-Mobile Wireless antenna facility located at 1394 Route 322,
Southington, CT, using the equipment information listed below. All calculations were performed per the
specifications under FCC OET 65. Since T-Mobile is proposing highly focused directional panel
antennas, which project most of the emitted energy out toward the horizon, the actual antenna pattern gain
value in the direction of the sample area was used. For this report the sample point is a 6 foot person
standing at the base of the tower
For all calculations, all equipment was calculated using the following assumptions:
1) 2 GSM channels (1935.000 MHz—to 1945.000 MHz) were considered for each sector of the
proposed installation.
2) 2 UMTS channels (2110.000 MHz to 2120.000 MHz / 2140.000 MHz to 2145.000 MHz)
were considered for each sector of the proposed installation
3) 2 LTE channels (2110.000 MHz to 2120.000 MHz / 2140.000 MHz to 2145.000 MHz) were
considered for each sector of the proposed installation
4) All radios at the proposed installation were considered to be running at full power and were
uncombined in their RF transmissions paths per carrier prescribed configuration. Per FCC
OET Bulletin No. 65 - Edition 97-01 recommendations to achieve the maximum anticipated
value at each sample point, all power levels emitting from the proposed antenna installation
are increased by a factor of 2.56 to account for possible in-phase reflections from the
surrounding environment. This is rarely the case, and if so, is never continuous.
5) For the following calculations the sample point was the top of a six foot person standing at
the base of the tower. The actual gain in this direction was used per the manufactures
supplied specifications.
6) The antenna used in this modeling is the Ericsson AIR21 for LTE, UMTS and GSM. This is
based on feedback from the carrier with regards to anticipated antenna selection. This antenna
has a 15.6 dBd gain value at its main lobe. Actual antenna gain values were used for all
calculations as per the manufacturers specifications
EBI Consulting environmental | engineering | due diligence
21 B Street .
Burlington, MA 01803 .
Tel: (781) 273.2500 .
Fax: (781) 273.3311
7) The antenna mounting height centerline of the proposed antennas is 128 feet above ground
level (AGL)
8) Emissions values for additional carriers were taken from the Connecticut Siting Council
active database. Values in this database are provided by the individual carriers themselves.
All calculation were done with respect to uncontrolled / general public threshold limits
Site ID
Site Addresss
Site Type
Antenna
Number Antenna Make Antenna Model Status Frequency Band Technology
Power
Out Per
Channel
(Watts)
Number of
Channels
Composite
Power
Antenna Gain
in direction
of sample
point (dBd)
Antenna
Height (ft)
analysis
height Cable Size
Cable Loss
(dB)
Additional
Loss ERP
Power
Density
Value
Power
Density
Percentage
1a Ericsson AIR21 B4A/B2P Active AWS - 2100 MHz LTE 60 2 120 -3.95 128 122 None 0 0 48.326044 1.16726 0.11673%
1b Ericsson AIR21 B4A/B2P Not Used - - 0 -3.95 128 122 None 0 0 0 0 0.00000%
2a Ericsson AIR21 B2A / B4P Active PCS - 1950 MHz GSM / UMTS 30 2 60 -3.95 128 122 1-5/8" 0 0 24.163022 0.58363 0.05836%
2B Ericsson AIR21 B2A / B4P Passive AWS - 2100 MHz UMTS 30 2 60 -3.95 128 122 1-5/8" 0 0 24.163022 0.58363 0.05836%
0.233%
Antenna
Number Antenna Make Antenna Model Status Frequency Band Technology
Power
Out Per
Channel
(Watts)
Number of
Channels
Composite
Power
Antenna Gain
in direction
of sample
point (dBd)
Antenna
Height (ft)
analysis
height Cable Size
Cable Loss
(dB)
Additional
Loss ERP
Power
Density
Value
Power
Density
Percentage
1a Ericsson AIR21 B4A/B2P Active AWS - 2100 MHz LTE 60 2 120 -3.95 128 122 None 0 0 48.326044 1.16726 0.11673%
1b Ericsson AIR21 B4A/B2P Not Used - - 0 -3.95 128 122 None 0 0 0 0 0.00000%
2a Ericsson AIR21 B2A / B4P Active PCS - 1950 MHz GSM / UMTS 30 2 60 -3.95 128 122 1-5/8" 0 0 24.163022 0.58363 0.05836%
28 Ericsson AIR21 B2A / B4P Passive AWS - 2100 MHz UMTS 30 2 60 -3.95 128 122 1-5/8" 0 0 24.163022 0.58363 0.05836%
0.233%
Antenna
Number Antenna Make Antenna Model Status Frequency Band Technology
Power
Out Per
Channel
(Watts)
Number of
Channels
Composite
Power
Antenna Gain
in direction
of sample
point (dBd)
Antenna
Height (ft)
analysis
height Cable Size
Cable Loss
(dB)
Additional
Loss ERP
Power
Density
Value
Power
Density
Percentage
1a Ericsson AIR21 B4A/B2P Active AWS - 2100 MHz LTE 60 2 120 -3.95 128 122 None 0 0 48.326044 1.16726 0.11673%
1b Ericsson AIR21 B4A/B2P Not Used - - 0 -3.95 128 122 None 0 0 0 0 0.00000%
2a Ericsson AIR21 B2A / B4P Active PCS - 1950 MHz GSM / UMTS 30 2 60 -3.95 128 122 1-5/8" 0 0 24.163022 0.58363 0.05836%
28 Ericsson AIR21 B2A / B4P Passive AWS - 2100 MHz UMTS 30 2 60 -3.95 128 122 1-5/8" 0 0 24.163022 0.58363 0.05836%
0.233%
6.910%
Sector total Power Density Value:
Site Composite MPE %
Total Site MPE % 47.390%
MPE %
0.700%
Sector 1
Sector 2
Sector 3
1394 Route 322, Southington, CT 06410
CT11453C - Southington (Sprint)
Monopole
Sector total Power Density Value:
Sector total Power Density Value:
Carrier
T-Mobile
AT&T 14.160%
MetroPCS 8.580%
Verizon Wireless 17.040%
Sprint
EBI Consulting environmental | engineering | due diligence
21 B Street .
Burlington, MA 01803 .
Tel: (781) 273.2500 .
Fax: (781) 273.3311
Summary
All calculations performed for this analysis yielded results that were well within the allowable limits for
general public exposure to RF Emissions.
The anticipated Maximum Composite contributions from the T-Mobile facility are 0.700% (0.233%
from each sector) of the allowable FCC established general public limit considering all three sectors
simultaneously sampled at the ground level.
The anticipated composite MPE value for this site assuming all carriers present is 47.390% of the
allowable FCC established general public limit sampled at the ground level. This is based upon values
listed in the Connecticut Siting Council database for existing carrier emissions.
FCC guidelines state that if a site is found to be out of compliance (over allowable thresholds), that
carriers over a 5% contribution to the composite value will require measures to bring the site into
compliance. For this facility, the composite values calculated were well within the allowable 100%
threshold standard per the federal government.
Scott Heffernan
RF Engineering Director
EBI Consulting
21 B Street
Burlington, MA 01803