Cryogenic Pressure Vessels: Progress and Plans · PDF fileCryogenic Pressure Vessel workshop,...

17
Cryogenic Pressure Vessel workshop, LLNL, February 15, 2011, p. 1 Cryogenic Pressure Vessels: Progress and Plans Salvador Aceves, Gene Berry, Francisco Espinosa, Ibo Matthews, Guillaume Petitpas, Tim Ross, Ray Smith, Vernon Switzer Lawrence Livermore National Laboratory February 15, 2011 This presentation does not contain any proprietary or confidential information

Transcript of Cryogenic Pressure Vessels: Progress and Plans · PDF fileCryogenic Pressure Vessel workshop,...

Page 1: Cryogenic Pressure Vessels: Progress and Plans · PDF fileCryogenic Pressure Vessel workshop, LLNL, February 15, 2011, p. 1 Cryogenic Pressure Vessels: Progress and Plans Salvador

Cryogenic Pressure Vessel workshop, LLNL, February 15, 2011, p. 1

Cryogenic Pressure Vessels:Progress and Plans

Salvador Aceves, Gene Berry,Francisco Espinosa, Ibo Matthews,

Guillaume Petitpas, Tim Ross,Ray Smith, Vernon Switzer

Lawrence Livermore National LaboratoryFebruary 15, 2011

This presentation does not contain any proprietary or confidential information

Page 2: Cryogenic Pressure Vessels: Progress and Plans · PDF fileCryogenic Pressure Vessel workshop, LLNL, February 15, 2011, p. 1 Cryogenic Pressure Vessels: Progress and Plans Salvador

Cryogenic Pressure Vessel workshop, LLNL, February 15, 2011, p. 2

The cryogenic pressure vessel concept has evolved from thermodynamic analysis into manufacture and demonstration

1998: thermodynamics2000: DOT/ISO testing 2004: demonstration

2007-2009: compact vessels 2010: para-ortho H2 conversion 2011: LH2 pump

Page 3: Cryogenic Pressure Vessels: Progress and Plans · PDF fileCryogenic Pressure Vessel workshop, LLNL, February 15, 2011, p. 1 Cryogenic Pressure Vessels: Progress and Plans Salvador

Cryogenic Pressure Vessel workshop, LLNL, February 15, 2011, p. 3

LLNL has refined three generations of cryogenic vessels exceeding 2015 storage targets fueled with 70g/L liquid H2

323 L, 10.4 kgLH2

235 L, 10.4 kgLH2

DOE 2010 targets

DOE 2015 targets

UltimateTargets

493 L, 9.5 kgLH2

Page 4: Cryogenic Pressure Vessels: Progress and Plans · PDF fileCryogenic Pressure Vessel workshop, LLNL, February 15, 2011, p. 1 Cryogenic Pressure Vessels: Progress and Plans Salvador

Cryogenic Pressure Vessel workshop, LLNL, February 15, 2011, p. 4

H2 Temperature

H2 Pressure

H2 massHeat input

Drop in apparent heat flux due to para-ortho conversion

App

aren

t hea

t flu

x [W

]

In a month long dormancy experiment, para-ortho conversionreduced heat transfer by half between days 12 and 24

%Ortho –H2

Page 5: Cryogenic Pressure Vessels: Progress and Plans · PDF fileCryogenic Pressure Vessel workshop, LLNL, February 15, 2011, p. 1 Cryogenic Pressure Vessels: Progress and Plans Salvador

Cryogenic Pressure Vessel workshop, LLNL, February 15, 2011, p. 5

July 13th

Experimental tests have been run over a wide range of conditions (temperature, density, vacuum quality)

December 20thFinal vacuum regeneration October 20th

refueling

Page 6: Cryogenic Pressure Vessels: Progress and Plans · PDF fileCryogenic Pressure Vessel workshop, LLNL, February 15, 2011, p. 1 Cryogenic Pressure Vessels: Progress and Plans Salvador

Cryogenic Pressure Vessel workshop, LLNL, February 15, 2011, p. 6

Para-ortho conversion became significant at ~75 K and extended dormancy by ~5 days for 70-90% full 151 L vessel

Presenter
Presentation Notes
Here are shown the highest densities for which para-ortho conversion has been observed. 60 and then 50, a density that allows complete conversion before reaching the rated pressure
Page 7: Cryogenic Pressure Vessels: Progress and Plans · PDF fileCryogenic Pressure Vessel workshop, LLNL, February 15, 2011, p. 1 Cryogenic Pressure Vessels: Progress and Plans Salvador

Cryogenic Pressure Vessel workshop, LLNL, February 15, 2011, p. 7

Para-ortho conversion became significant at ~75 K and extended dormancy by ~5 days for 70-90% full 151 L vessel

75 K

75 K

Presenter
Presentation Notes
Here are shown the highest densities for which para-ortho conversion has been observed. 60 and then 50, a density that allows complete conversion before reaching the rated pressure
Page 8: Cryogenic Pressure Vessels: Progress and Plans · PDF fileCryogenic Pressure Vessel workshop, LLNL, February 15, 2011, p. 1 Cryogenic Pressure Vessels: Progress and Plans Salvador

Cryogenic Pressure Vessel workshop, LLNL, February 15, 2011, p. 8

In both industrial and laboratory environments,low heat transfer requires < 1 mTorr vacuum quality

LaboratoryVertical MLI sheets

No penetrationsNo supports

No trapped residual gasesNo layer pinching

IndustrialHorizontal pipeline

sagging

Source: NASA. Performance characterization of perforated multilayer insulation blankets, Fesmire, Augustynowicz, DarveThermal performance of cryogenic piping multilayer insulation in actual field installations. Fesmire, Augustynowicz

Page 9: Cryogenic Pressure Vessels: Progress and Plans · PDF fileCryogenic Pressure Vessel workshop, LLNL, February 15, 2011, p. 1 Cryogenic Pressure Vessels: Progress and Plans Salvador

Cryogenic Pressure Vessel workshop, LLNL, February 15, 2011, p. 9

LLNL insulation performance follows the same trend

LLNL

Source: NASA. Performance characterization of perforated multilayer insulation blankets, Fesmire, Augustynowicz, DarveThermal performance of cryogenic piping multilayer insulation in actual field installations. Fesmire, Augustynowicz

LaboratoryVertical MLI sheets

No penetrationsNo supports

No trapped residual gasesNo layer pinching

IndustrialHorizontal pipeline

sagging

Page 10: Cryogenic Pressure Vessels: Progress and Plans · PDF fileCryogenic Pressure Vessel workshop, LLNL, February 15, 2011, p. 1 Cryogenic Pressure Vessels: Progress and Plans Salvador

Cryogenic Pressure Vessel workshop, LLNL, February 15, 2011, p. 10

Experiments show viable indicated vacuum levels up to ~150 K for 4 months

Page 11: Cryogenic Pressure Vessels: Progress and Plans · PDF fileCryogenic Pressure Vessel workshop, LLNL, February 15, 2011, p. 1 Cryogenic Pressure Vessels: Progress and Plans Salvador

Cryogenic Pressure Vessel workshop, LLNL, February 15, 2011, p. 11

Most cryogenic vessels may remain colder than 150 Kdue to expansion work during hydrogen extraction

Source: BMW

Page 12: Cryogenic Pressure Vessels: Progress and Plans · PDF fileCryogenic Pressure Vessel workshop, LLNL, February 15, 2011, p. 1 Cryogenic Pressure Vessels: Progress and Plans Salvador

Cryogenic Pressure Vessel workshop, LLNL, February 15, 2011, p. 12

Experiments show viable indicated vacuum levels up to ~150 K for 4 months

Page 13: Cryogenic Pressure Vessels: Progress and Plans · PDF fileCryogenic Pressure Vessel workshop, LLNL, February 15, 2011, p. 1 Cryogenic Pressure Vessels: Progress and Plans Salvador

Cryogenic Pressure Vessel workshop, LLNL, February 15, 2011, p. 13

LH2 pump will enable rapid high density refueling even for initially warm and/or pressurized vessels

• A high pressure (up to 880 bar) LH2 pump offers rapid single phase refueling without boil-off

• Single flow refueling can be reliable and cost effective

• Pump expected ~12 months after contract, possibly 2/12

• Contract is now in procurement. To be finalized within 1-2 months

• LLNL is also responsible for basic services: electricity, phone line, concrete pad, foundation

Page 14: Cryogenic Pressure Vessels: Progress and Plans · PDF fileCryogenic Pressure Vessel workshop, LLNL, February 15, 2011, p. 1 Cryogenic Pressure Vessels: Progress and Plans Salvador

Cryogenic Pressure Vessel workshop, LLNL, February 15, 2011, p. 14

An 80 L 700 bar cryogenic vessel will be located forward of existing 151 L 350 bar vessel. Fueling both explores

scale and transient vs. steady state refueling differences

Page 15: Cryogenic Pressure Vessels: Progress and Plans · PDF fileCryogenic Pressure Vessel workshop, LLNL, February 15, 2011, p. 1 Cryogenic Pressure Vessels: Progress and Plans Salvador

Cryogenic Pressure Vessel workshop, LLNL, February 15, 2011, p. 15

We project 55% volumetric efficiency for 80 L & 700 bar cryogenic vessel design with aspect ratio ~2.5

• Capacity: 5.6-7.4 kg (L)H2 @ 1-700 bar

• Volume: 153 liters (10 L accessories)

• Weight: 90 kg total (15 kg accessories)

• 3 mm aluminum vacuum jacket 13 kg

• 80 L capacity 700 bar vessel 62 kg

Page 16: Cryogenic Pressure Vessels: Progress and Plans · PDF fileCryogenic Pressure Vessel workshop, LLNL, February 15, 2011, p. 1 Cryogenic Pressure Vessels: Progress and Plans Salvador

Cryogenic Pressure Vessel workshop, LLNL, February 15, 2011, p. 16

H2

pres

sure

(psi

)

Days parked after fueling with LH2

Fully capturing para-ortho conversion demands P > 5000 psi and/or vessel volume > 80 L

110

50% ortho-H2

87 K

100 K 100

91

82

73

64

55

46

37

29

H2

tem

pera

ture

(K)

80 L vesselInitially stores 5.6 kg H2 @ 20.3 K, 1 atm, 95% para-H2

20

Page 17: Cryogenic Pressure Vessels: Progress and Plans · PDF fileCryogenic Pressure Vessel workshop, LLNL, February 15, 2011, p. 1 Cryogenic Pressure Vessels: Progress and Plans Salvador

Cryogenic Pressure Vessel workshop, LLNL, February 15, 2011, p. 17

Summary: we will combinea high pressure LH2 pump & lighter, smaller vessel

with a comprehensive experimental strategy

• Rapid low loss refueling at higher density up to 880 bar, 90 gH2/L

• Simpler high pressure operation with single inlet/outlet line

• Realistic (warm) refueling conditions: partially full, <99% para H2

• Measure H2 temperature in addition to vessel, piping and jacket temperatures by inserting silicon diodes in vessel

• Second independent capacity measurement by weighing vessel ideally during refueling

• Aluminum jacket material to improve weight, capacity measurement, and thermal uniformity

• Determine vacuum quality intrinsic to composite wall vessels