Cross Connection Control Cross Connections ….. are they effecting your Water System? Gander, Newfoundland March 26, 2003 Barry MacNabb Plumbing Inspector City of Fredericton

Transcript of Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross...

Page 1: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Cross Connection Control

Cross Connections …..

are they effecting your Water System?

Gander, NewfoundlandMarch 26, 2003

Barry MacNabbPlumbing InspectorCity of Fredericton

Page 2: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Topics to be discussed…

• What is a Cross Connection?

• Why is this an issue

• What to look for

• Cross Connection cases in Atlantic Canada

• Hazard Classifications

• Cross Connection Programs…what’s needed

Page 3: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Introduction

What is a Cross Connection?

…any actual or potential connection between a potable water system and any source of pollutionor contamination. By-pass arrangements, jumper connections, removable sections, swivel or change-over devices, or any other temporary or permanentarrangements through which backflow may occur…

Page 4: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

IIs this a Cross Connection?

Page 5: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and
Page 6: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and
Page 7: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and
Page 8: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Potential Cross-Connection

Water service

Sewer Line

Water line directly connected to the sewer in order to run water to prevent freezing

Page 9: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Why is Cross Connection an issue?

•One of the greatest risks to potable waterquality.

•Puts potable water into contact with non-potablesubstances

•Range from invisible and harmless to deadly poisons

Page 10: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Why is Cross Connection an issue?

The result of a Cross Connection

• May cause only a complaint about the aesthetics of the water

• Public will definitely lose confidence in your watersystem

Page 11: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Why is Cross Connection an issue?

•May cause severe illness

•May cause slow or quick death from poisonor disease

•40% of waterborne illness is caused byCross Connections/line breaks

Page 12: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

What to look for….

Page 13: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

What to look for…

Everyone sees Cross Connections every daybut in actual fact, they don’t see them….

•Hoses dangling in sinks.

•Dispensing units connected to water supply.

•Apparatus which boosts water pressure greaterthan supply pressure.

•Check everything which is water supplied.

Page 14: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and
Page 15: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Two types of Backflow

•Backsiphonage

•Backpressure

What to look for….

Page 16: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

•high withdrawals

•watermain breaks

•system or plumbing shutdowns

•suction due to booster pumps

Backsiphonage

Page 17: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and
Page 18: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and
Page 19: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and
Page 20: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and
Page 21: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and
Page 22: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

What is this doing to your system?What is this doing to your system?

Page 23: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and
Page 24: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and
Page 25: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Backpressure

•Pumps

•Boilers

•Compressed gases

Page 26: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and
Page 27: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and
Page 28: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and
Page 29: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Documented Cases in Atlantic Canada

•Coffee Shop

•Office Building

•Restaurant

•University Campus Building

Page 30: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Coffee Shop

•Soap/Chemical Dispenser

•Coffee Machine

•Lawsuit filed…..unknown cash settlement

Page 31: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and
Page 32: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and
Page 33: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Coffee Shop Conclusion

Loss of customer confidence in stores abilityto ensure good product. Loss of confidence in the Utilities Water System.

•Customer settled out of court for an undisclosedamount. $$$$$$$$

•Owner upgraded all his shops to conform to present Plumbing Code

Page 34: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Office Building

•Cooling Tower and Photo Developer

•Building had fluctuating water pressure

•Faulty valve…system drained to replace valve

When system re-energized, contaminantsentered water system and was found in watercoolers, sinks and washrooms

Page 35: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and
Page 36: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and
Page 37: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and
Page 38: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and
Page 39: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Office Building Conclusion

Plumber actually initiated the Cross Connectionwhen he drained the system down and replaced valve

•Local Union threatened to take employer tocourt for possible illness of employees

•Building vacated for three working days

•Insurance company required that all buildings to be surveyed and Backflow Preventersinstalled (pollution exclusion clause)

Page 40: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Restaurant

•CO2 pump on Post-Mix Soda Dispenser

•Coffee Machines on same water line

With no Backflow Preventer installed and theCO2 pushed into copper water line to coffee machines which reacted to form

Page 41: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and
Page 42: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and
Page 43: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Restaurant…Conclusion

When CO2 reacted with the copper it formeda brownish foam head on the coffee and changedthe flavor to a very bitter taste

•Department of Health ordered a complete surveyof the Restaurant for Cross Connections

•Patrons never regained confidence in the management of Restaurant and it eventually closed

Page 44: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

University Campus Building

•Plumbing Contractor installing Backflow Preventeron domestic water service

•Glycol cooled compressor on a Deep Freeze condensing Unit

Page 45: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and
Page 46: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

University Campus Building

Plumbing Contractor drained down portion of buildingto install Backflow Preventer but did not check what may possibly backsiphon into the system.Completed installation and re-energized system.Didn’t realize that when system drained, he allowedall the Glycol from the compressor to enter the potablewater system.

Page 47: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and
Page 48: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

6Deep freeze condensing unit with Ethylene Glycol exchanger. This unit has a direct connection to the domestic water line. RP to be installed.

Install RP

Page 49: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

University Campus BuildingConclusion…

•Entire Building had to be flushed and sampledfor a minimum period of 48 hours until the Department of Health was satisfied the waterwas clear of all pollutants.

•All staff and students were not permitted in building until samples were clear.

•Building was surveyed for other Cross Connections.

Page 50: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Other Cross Connections found at CampusBuilding…

Standpipe for Fire Hose Cabinets

Page 51: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Make-up line for cooling tower and glycol loop

Other Cross Connections foundat Campus Building…

Page 52: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Growth Chambers using water for humidification

Other Cross Connections found atCampus Building..

Page 53: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Hazard Classifications

•Minor Hazard

•Moderate Hazard

•Severe Hazard

Page 54: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Minor Hazard…

Any cross connection or potential cross connectionthat constitutes only a nuisance, with no possibility of any health hazard.

•Cooking kettles•Flexible showerheads with hose•Steam tables•Distillers

Page 55: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Moderate Hazard..

Any minor hazard that has a low probabilityof becoming a severe hazard….

•Basin or Bathtub•Clothes Washer•Potato Peeler•Elementary School

Page 56: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Severe Hazard…

Any cross connection or potential cross connection involving any substance that could be a dangerto health

•Bedpan Washer•Hospital•Morgue•Cooling Tower•Pressure Washer•Boat Marina

Page 57: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

How to start a Cross ConnectionControl Program…

Establish Authority

This can be done with Provincial Legislationto provide the necessary authority to carry out the functions of the program

Page 58: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and
Page 59: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Prepare a By-Law

Generally integrated into the Water andSewer By-Law, as the Utility is the body who will be administering the Program.Within By-Law, it must be determined who is responsible for the installation, maintenanceand testing costs of the Backflow Preventers.Generally becomes the responsibility of the owner of the premises.

Page 60: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Put teeth in your By-Law

…No owner or other person shall connect,cause to be connected, or allow to remainconnected, any piping, fixture, fitting, container, or appliance in a manner which, under any circumstance, could allow water, waste water, or any other substance toenter the Municipal Water System.

Page 61: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Put teeth in your By-Law

…if a condition is found to exist, which in theopinion of the Director of Engineering and Public Works is contrary to subsection (1) hereof, the Director may either shut off theservice or services, or give notice to the customer to correct the fault within a specifiedperiod…

Page 62: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Other crucial sections to By-Law

•Criteria for testing

•Criteria for Licensing Certified Testers

•Enforcement

•Installation Requirements

•Criteria for Maintenance and Repair

•Reference documents used to select, install and test Backflow Preventers

Page 63: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Documents needed

Documents to be utilized and referenced

•CSA B64.10-01, CSA B64.10-01.1-Standardfor the Selection, Installation, Maintenanceand Field Testing of Backflow Preventers

•National Plumbing Code of Canada, Latest Edition

Page 64: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and
Page 65: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and
Page 66: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Staff Training

•Have both inside and outside staff trained byan accredited Cross Connection Control facility(A.W.W.A. or A.C.W.W.A.)

•Courses range from Awareness,Testersto Surveyors

•Gives staff the knowledge and credibility to properly manage and maintain a Cross Connectionprogram

Page 67: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Have all Premises Surveyed

All buildings that are connected to yourdistribution system. Using the CSA Standardand the National Plumbing Code you can determine what is required for Premise, Zone, and Point of Use protection.

Have devices installed and tested which would complete the first step in your program.

Page 68: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and
Page 69: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Catalogue the Devices

To manage the testing requirements forBackflow Preventers installed throughoutyour Distribution System, you can manually record, customize your current computer systemor purchase a program which will assist you innotifying owners when devices must be tested.(TheCSA Standard states, testable Backflow Preventersmust be tested at least annually by a Certified Tester.

Page 70: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and
Page 71: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and
Page 72: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Sample Long Range Plan

•Legislation

•By-Law

•Staff Training

Public Education Program (continuous)

Page 73: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Sample Long Range Plan Continued…

•Survey Buildings for Premise Isolation (domestic)•Survey and retrofit Municipal Buildings•Develop retrofit Strategy for Private Sector•Contact and enforce Severe Hazard Building Owners•Contact and enforce Moderate Hazard Building Owners•Contact and enforce Minor Hazard Building Owners•New building enforcement (continuous)•Begin retrofitting Sprinkler Systems on all buildings•Enforce annual testing of Backflow Preventers

Page 74: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Long Range Plan Conclusion

This sample plan has an estimated activitytimeline of approximately 6 years.

The order in which it is written is from Municipalities which have an active CrossConnection Control Program, but some of the items listed can be changed around to suit any water purveyors needs.

Page 75: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Protection?

•Protect the Public

•Protect your investment

Page 76: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

Something to think about…

A Cross Connection Program providesthe necessary completeness to a Water Quality Plan. It fits in besideSource protection, Treatment, DistributionSystem Maintenance and Monitoring.

Page 77: Cross Connection Control Cross Connections ….. are …€¦ · Introduction What is a Cross Connection? …any actual or potential connection between a potable water system and

The End

Questions?