Contrive LED Catalog 2016
-
Upload
sonu-goyal -
Category
Documents
-
view
121 -
download
2
Transcript of Contrive LED Catalog 2016
Annant Enersol Pvt. Ltd. (A Contrive Group Company) G1 – 231, Kuber Industrial Area, Ranpur Kota – 325003 (Raj.)
www.annant.com; [email protected]; +91-9672992544, 9672994444 Page 1
Products Designed and Developed by IIT Mumbai Alumni
“Conservation doesn’t cost anything, but saves everything”
Annant Enersol Pvt. Ltd. (A Contrive Group Company) G1 – 231, Kuber Industrial Area, Ranpur Kota – 325003 (Raj.)
www.annant.com; [email protected]; +91-9672992544, 9672994444 Page 2
Company Introduction
Annant Enersol is a clean & green energy solution provider company with the focus on energy
efficient LED based lighting system, solar PV system and energy conservation. The company
envisages a green future by embracing green technology that contributes towards reducing carbon
emission. It is promoting energy efficient and green products under the brand name "Contrive".
The company is a part of Contrive Group (an ISO 9001:2008 certified company), one of the leading
industrial automation and energy efficient solutions provider in the state of Rajasthan. Since year
2001, Contrive is providing 24x7 services to all type of process plants and original equipment
manufacturers, such as cement, power, mining & minerals, textile and many more. On the
experience of the parent company, Annant Enersol is deploying innovative strategies, systems and
technologies to revolutionize LED based lighting, solar power and energy conservation.
Our products follow industry norms & international quality standards and are designed to cater the
needs of residential, commercial as well as industrial customers. We are MNRE empanelled vendor
for On-grid and small Solar PV Systems.
Our products and services include, but not limited to:
LED Lights
o Indoor: Bulb, Tube Light, PLL, Panel Light o Outdoor: Street Light, Flood Light o Industrial: Bay Light, Flame Proof and Weather Proof Lights (Well Glass, Flood Light,
Clean Room Fitting) o Retrofitting: Lights can be customized for retrofitting as per customer specifications,
e.g., FLP Well Glass, PLL etc.
Solar PV Systems
o Solar Street Light o Rooftop Solar PV System (On & Off grid) o Solar Irrigation System
Design, Consultancy & Manufacturing
o Complete lighting design & consultancy for all applications such as home, multi-storey building, show-room, godown, shed, shop floor, petrol pump, blast room, paint room, spray booth, street, garden etc.
o Complete electrical design & consultancy for all type of buildings starting from transformer to electrical appliances.
o Design & manufacturing of all type of electrical panels, like PCC, MCC, JB, APFC, AMF, etc.
Annant Enersol Pvt. Ltd. (A Contrive Group Company) G1 – 231, Kuber Industrial Area, Ranpur Kota – 325003 (Raj.)
www.annant.com; [email protected]; +91-9672992544, 9672994444 Page 3
LED Products – Indoor
Bulb
Applications o Home, Office, Institute, College, Hotel, Hospital, Common Area
Installation o Retrofit for conventional B22 bulb holders
Model No. Electrical
Parameters CCT (K)
LED Luminous Efficacy (Lm/W)
CRI
CLL-BULB 5W 5W/ 90-275VAC 6000-6500 > 120 > 75
CLL-BULB 7W 7W/ 90-275VAC 6000-6500 > 120 > 75
CLL-BULB 9W 9W/ 90-275VAC 6000-6500 > 120 > 75
Slim Panel Down Light
Applications o Home, Office, Institute, College, Hotel, Restaurant, Hospital, Show Room, Shopping
Mall, Common Area
Installation o Retrofit for standard CFL/ halogen down light fixtures
Model No. Dimension Electrical
Parameters CCT (K)
LED Luminous Efficacy (Lm/W)
CRI
CLL-SPDL 6W SQ & RD - 4"
Cutout 6W/ 90-275VAC 3000-6500 > 120 > 75
CLL-SPDL 12W SQ & RD - 6"
Cutout 12W/ 90-275VAC 3000-6500 > 120 > 75
CLL-SPDL 15W SQ & RD - 6"
Cutout 15W/ 90-275VAC 3000-6500 > 120 > 75
Annant Enersol Pvt. Ltd. (A Contrive Group Company) G1 – 231, Kuber Industrial Area, Ranpur Kota – 325003 (Raj.)
www.annant.com; [email protected]; +91-9672992544, 9672994444 Page 4
Surface Panel Down Light
Applications o Home, Office, Institute, College, Hotel, Restaurant, Hospital, Show Room, Shopping
Mall, Common Area
Installation o Retrofit for standard CFL/ halogen down light fixtures
Model No. Dimension Electrical
Parameters CCT (K)
LED Luminous Efficacy (Lm/W)
CRI
CLL-SFDL 6W SQ & RD - 5" 6W/ 90-275VAC 3000-6500 > 120 > 75
CLL-SFDL 12W SQ & RD - 7" 12W/ 90-275VAC 3000-6500 > 120 > 75
CLL-SFDL 18W SQ & RD - 7" 18W/ 90-275VAC 3000-6500 > 120 > 75
Tube Light/ PL Lamp
Applications o Home, Office, Institute, College, Hotel, Hospital, Show Room , Shopping Mall,
Common Area
Installation o Retrofit for standard T8 TFL, PLL and wall mount in T5.
Model No. Dimension Electrical
Parameters CCT (K)
LED Luminous Efficacy (Lm/W)
CRI
CLL-T5WM 9W
Wall Mount - 2' 9W/ 90-275VAC 6000 > 130 > 75
CLL-T5WM 18W
Wall Mount - 4' 18W/ 90-275VAC 6000 > 130 > 75
CLL-T5WM 36W
Wall Mount - 4' 36W/ 90-275VAC 6000 > 130 > 75
CLL-T8RF 18W
Retrofit - 4' 18W/ 90-275VAC 6000 > 130 > 75
CLL-PLLRF 9W
Retrofit – 200mm
9W/ 90-275VAC 6000 > 130 > 75
CLL-PLLRF 18W
Retrofit – 400mm
18W/ 90-275VAC 6000 > 130 > 75
Annant Enersol Pvt. Ltd. (A Contrive Group Company) G1 – 231, Kuber Industrial Area, Ranpur Kota – 325003 (Raj.)
www.annant.com; [email protected]; +91-9672992544, 9672994444 Page 5
LED Products – Outdoor
Flood Light
Models/ Variants o 30W, 45W & 60W available in both AC and 12-48VDC options o 45o, 60o, 90o & 120o lenses are available to customize the product as per application
Applications o Façade, Spot Lighting, Shopping Mall, Playing Arena, Fitness Center, Hoarding, Display
Board, Industrial
Installation o Retrofit for standard HID lamps (HPSV/ HPMV/ MH)
Model No. Electrical
Parameters CCT (K)
LED Luminous Efficacy (Lm/W)
CRI
CLL-FLCOB 30W 30W/ 90-275VAC
or 12-48VDC 6000-6500 > 140 > 80
CLL-FLCOB 45W 45W/ 90-275VAC
or 12-48VDC 6000-6500 > 140 > 80
CLL-FLCOB 60W 60W/ 90-275VAC
or 12-48VDC 6000-6500 > 140 > 80
CLL-FLCOB 90W 90W/ 90-275VAC 6000-6500 > 140 > 80
CLL-FLCOB 120W 120W/ 90-275VAC 6000-6500 > 140 > 80
CLL-FLCOB 120W (BLUE)
120W/ 90-275VAC 6000-6500 > 140 > 80
CLL-FLCOB 150W (BLUE)
150W/ 90-275VAC 6000-6500 > 140 > 80
CLL-FLCOB 150W 150W/ 90-275VAC 6000-6500 > 140 > 80
CLL-FLCOB 180W 180W/ 90-275VAC 6000-6500 > 140 > 80
Annant Enersol Pvt. Ltd. (A Contrive Group Company) G1 – 231, Kuber Industrial Area, Ranpur Kota – 325003 (Raj.)
www.annant.com; [email protected]; +91-9672992544, 9672994444 Page 6
Street Light (Conventional & Solar PV)
Models/ Variants o Available in three variants: Slim, SMD & COB Lens o Solar street lights available in 20W, 30W, 50W & 60W with in-built dusk-to-dawn feature
Applications o Street, Garden, Campus, Parking, Highway, Industrial, Residential, Commercial
Installation o Retrofit for standard HID lamps (HPSV/ HPMV/ MH)
Model No. Electrical
Parameters CCT (K)
LED Luminous Efficacy (Lm/W)
CRI
CLL-SLSLIM 15W 15W/ 90-275VAC 6000-6500 > 140 > 80
CLL-SLSLIM 20W 20W/ 90-275VAC 6000-6500 > 140 > 80
CLL-SLSMD 20W 20W/ 90-275VAC 6000-6500 > 130 > 75
CLL-SLSMD 30W 30W/ 90-275VAC 6000-6500 > 130 > 75
CLL-SLSMD 50W 50W/ 90-275VAC 6000-6500 > 130 > 75
CLL-SLSMD 60W 60W/ 90-275VAC 6000-6500 > 130 > 75
CLL-SLSMD 90W 90W/ 90-275VAC 6000-6500 > 130 > 75
CLL-SLCOB 20W 20W/ 90-275VAC 6000-6500 > 140 > 80
CLL-SLCOB 30W 30W/ 90-275VAC 6000-6500 > 140 > 80
CLL-SLCOB 45W 45W/ 90-275VAC 6000-6500 > 140 > 80
CLL-SLCOB 60W 60W/ 90-275VAC 6000-6500 > 140 > 80
CLL-SLCOB 90W 90W/ 90-275VAC 6000-6500 > 140 > 80
CLL-SLCOB 120W 120W/ 90-275VAC 6000-6500 > 140 > 80
Annant Enersol Pvt. Ltd. (A Contrive Group Company) G1 – 231, Kuber Industrial Area, Ranpur Kota – 325003 (Raj.)
www.annant.com; [email protected]; +91-9672992544, 9672994444 Page 7
LED Products – Industrial
Low/ High - Bay Light
Models/ Variants o 60o, 90o & 120o lenses are available to customize the product as per application
Applications o Factory, Shop Floor, Godown, Other Commercial Facilities
Installation o Retrofit for standard HID lamps (HPSV/ HPMV/ MH)
Model No. Electrical
Parameters CCT (K)
LED Luminous Efficacy (Lm/W)
CRI
CLL-BLCOB 60W 60W/ 90-275VAC 6000-6500 > 140 > 80
CLL-BLCOB 90W 90W/ 90-275VAC 6000-6500 > 140 > 80
CLL-BLCOB 120W 120W/ 90-275VAC 6000-6500 > 140 > 80
CLL-BLCOB 150W 150W/ 90-275VAC 6000-6500 > 140 > 80
CLL-BLCOB 180W 180W/ 90-275VAC 6000-6500 > 140 > 80
CLL-BLCOB 200W 200W/ 90-275VAC 6000-6500 > 140 > 80
CLL-BLCOB 220W 220W/ 90-275VAC 6000-6500 > 140 > 80
Well Glass
Models/ Variants o Available in weather proof and flame proof enclosures (CMRI certified) o Retrofitting is also possible in all flame proof fixtures
Applications o Chemical Plant, Cement Plant, Oil Refinery, Gas Plant, Boiler Room, Mine Shaft
Installation o Retrofit for standard HID lamps (HPSV/ HPMV/ MH)
Annant Enersol Pvt. Ltd. (A Contrive Group Company) G1 – 231, Kuber Industrial Area, Ranpur Kota – 325003 (Raj.)
www.annant.com; [email protected]; +91-9672992544, 9672994444 Page 8
Model No. Electrical
Parameters CCT (K)
LED Luminous Efficacy (Lm/W)
CRI
CLL-WPWG 15W 15W/ 90-275VAC 6000-6500 > 140 > 80
CLL-WPWG 20W 20W/ 90-275VAC 6000-6500 > 140 > 80
CLL-WPWG 30W 30W/ 90-275VAC 6000-6500 > 140 > 80
CLL-WPWG 40W 15W/ 90-275VAC 6000-6500 > 140 > 80
CLL-FLPWG 15W 15W/ 90-275VAC 6000-6500 > 140 > 80
CLL-FLPWG 20W 20W/ 90-275VAC 6000-6500 > 140 > 80
CLL-FLPWG 30W 30W/ 90-275VAC 6000-6500 > 140 > 80
CLL-FLPWG 40W 40W/ 90-275VAC 6000-6500 > 140 > 80
Solar Street Light System
Features
Solar street light system includes solar module, LED light, charge controller, dusk to
dawn controller, battery, battery enclosure and complete pole assembly & mounting
structure
Applications o Street, Garden, Campus, Parking, Highway, Industrial, Residential, Commercial
Installation o Retrofit for standard HID lamps (HPSV/ HPMV/ MH)
Model No. LED Light Power Consumption (W)
Solar Panel (W) Battery Days of
Autonomy Pole
Height (m)
CLL-SSL 20W 20 100 12V/ 60Ah 2 5
CLL-SSL 30W 30 150 12V/ 100Ah 2 5
CLL-SSL 60W 60 100 12V/ 75Ah 1 7
Annant Enersol Pvt. Ltd. (A Contrive Group Company) G1 – 231, Kuber Industrial Area, Ranpur Kota – 325003 (Raj.)
www.annant.com; [email protected]; +91-9672992544, 9672994444 Page 9
Contrive LED Light Benefits
Very low power consumption,
o up to 85% less than incandescent lamp
o up to 60% less than fluorescent lamp
Long life, up to 15 years
Flicker free, instant-on performance
No light pollution, no infrared or ultraviolet emissions
Wide operating voltage
Resistance to breakage and vibration
Rapid on-off cycling capability without detrimental effects
Good performance in cold temperatures
Environment friendly, contains no mercury or heavy metals
Repairable and recyclable
2 years warranty
Contrive LED Light Specifications & Features
High purity aluminum heat sink for better thermal dissipation
Rated life of L70 @ 50000 hrs ensures uninterrupted, maintenance free long service life
Excellent colour rendering capabilities (CRI > 70) reveals true colour of your surrounding
space
In built electrical protections like over voltage, short circuit, over loading for additional
safety precautions
Maintains power factor > 0.9
Colours available from warm white and cool white
IP 20 (indoor), IP 65/66 (outdoor) compliance
Our Valuable Customers