COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

44
COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF SURVEY REPORT For: LA HABRA HIGH SCHOOL AQUATICS FACILITY 801 HIGHLANDER AVENUE, LA HABRA CALIFORNIA, 90631 Presented To: FULLERTON JOINT UNION HIGH SCHOOL DISTRICT 1051 WEST BASTANCHURY ROAD FULLERTON, CALIFORNIA 92833 Presented By: 1322 Bell Avenue, Suite 1N Tustin, California 92780 Phone: 714-247-0024 Fax: 714-247-0025 Bainbridge Project # 20027913.12 March 11, 2020

Transcript of COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

Page 1: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF SURVEY REPORT

For:

LA HABRA HIGH SCHOOL AQUATICS FACILITY

801 HIGHLANDER AVENUE, LA HABRA CALIFORNIA, 90631

Presented To:

FULLERTON JOINT UNION HIGH SCHOOL DISTRICT 1051 WEST BASTANCHURY ROAD FULLERTON, CALIFORNIA 92833

Presented By:

1322 Bell Avenue, Suite 1N Tustin, California 92780 Phone: 714-247-0024 Fax: 714-247-0025

Bainbridge Project # 20027913.12

March 11, 2020

Page 2: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

March 11, 2020 Ms. Kate Kwon Assistant Construction Projects Manager Fullerton Joint Union High School District 1051 West Bastanchury Road Fullerton, California 92833 RE: Phase 1 – Comprehensive Asbestos and Lead-Based Paint XRF Survey Report for

the La Habra High School – Aquatics Facility located at 801 Highlander Avenue, La Habra California, 90631

Dear Ms. Kwon: At the request of the Fullerton Joint Union High School District (FJUHSD), Bainbridge Environmental Consultants, Inc. (Bainbridge) conducted a comprehensive asbestos and lead-based paint XRF survey at La Habra High School – Aquatics Facility for the upcoming/scheduled Pool Alteration Project located at the above-mentioned address. This document has been prepared for the sole use of Fullerton Joint Union High School District, their authorized agents, and any State, or local agencies involved in this project. No other party should rely on the information contained herein without prior written consent of Bainbridge. Thank you for the opportunity to be of service. Please do not hesitate to call us with any questions. We look forward to assisting you in the future. Sincerely, Bainbridge Environmental Consultants, Inc.

Karlin Cisco Director of Operations CAC # 16-5626 CDPH LRC I/A #00003694 Bainbridge Project #: 20027913.12 KC/bb

Page 3: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

Fullerton Joint Union High School District Bainbridge Environmental Consultants, Inc. La Habra High School – Aquatics Facility Comprehensive Asbestos and Lead-Based Paint XRF Survey Report March 11, 2020

Page 3

TABLE OF CONTENTS

Section

1.0 Asbestos Survey/Investigation 1.1 Asbestos Findings 1.2 Asbestos Recommendations 1.3 Disclaimer And Limitations For Asbestos Related Projects

2.0 Lead-Based Paint XRF Testing of Painted Surfaces 2.1 Lead-based Paint XRF Findings 2.2 Lead-based Paint Recommendations 2.3 Disclaimer And Limitations For Lead-Based Paint and Components

Appendices

A. ASBESTOS FIELD DATA AND LABORATORY RESULTS B. LEAD-BASED PAINT XRF FIELD DATA AND ANALYTICAL RESULTS C. ASBESTOS AND LEAD-BASED PAINT INSPECTOR’S STATE CERTIFICATIONS D. ASBESTOS AND LEAD-BASED PAINT XRF SAMPLE LOCATION DRAWINGS E. SURVEY PHOTOGRAPHS

Page 4: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

Fullerton Joint Union High School District Bainbridge Environmental Consultants, Inc. La Habra High School – Aquatics Facility Comprehensive Asbestos and Lead-Based Paint XRF Survey Report March 11, 2020

Page 4

1.0 Asbestos Survey/Investigation

Marco Silva, DOSH Certified Site Surveillance Technician (CSST) #19-6694, under the direction of Karlin Cisco, DOSH Certified Asbestos Consultant (CAC) #16-5626, of Bainbridge, performed the comprehensive survey activities and collected the suspect asbestos-containing building material bulk samples for laboratory analysis at La Habra High School – Aquatics Facility located at 801 Highlander Avenue, La Habra, California 90631. The survey was performed on the dates of March 3 & 4, 2020, in addition to a client acceptance walk conducted on March 6, 2020. Our comprehensive asbestos survey consisted of bulk sampling and collection of suspect asbestos-containing materials scheduled to be impacted during the upcoming/scheduled pool alteration project. This report reviews and summarizes the findings outlined in the attached asbestos bulk sample log and laboratory analysis report. During this inspection, several criteria including bulk sampling were used to properly assess areas investigated. Visual and tactile assessments of suspect asbestos-containing building materials provided the basis for these criteria and allowed the inspector to group the materials into homogenous areas. Bainbridge conducted the asbestos bulk sampling of the subject Aquatics Facility in compliance with the following Federal, State, and Local regulations: Code of Federal Regulations (CFR): • 40 CFR Part 763 - Asbestos Containing Materials In Schools. • 29 CFR 1910.1001 - Occupational Exposure to Asbestos, Tremolite, Anthophyllite/Actinolite • 29 CFR 1910.1101 - Asbestos • 29 CFR 1910.1200 - Hazard Communication • 29 CFR 1910.20 - Access to Employee Exposure and Medical Records • 29 CFR 1910.132 - General Requirements – Personal Protective Equipment • 29 CFR 1910.133 - Eye and Face Protection • 29 CFR 1910.134 - Respiratory Protection • 29 CFR 1910.145 - Specifications for Accident Prevention, Signs and Tags • 29 CFR 1910.1101 - Asbestos Standard for construction Industry • 40 CFR 61 - Sub-part A General Conditions • 40 CFR 61 - Sub-part M National Emission Standards for Asbestos • 40 CFR 61.152 - Standard for Waste Disposal for Manufacturing, Demolition, Renovation,

Spraying and Fabrication Operations. U.S. Environmental Protection Agency (EPA): • Publication No. 560/5-85-024 - Guidance for Controlling Asbestos-Containing Materials in

Buildings.

Title 8 California Code of Regulations (CCR): • Section 1529 - Asbestos • Section 5208 - General Industry Safety Orders South Coast Air Quality Management (SCAQMD): • Rule 1403- Asbestos Emissions from Demolition/Renovation Activities.

Page 5: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

Fullerton Joint Union High School District Bainbridge Environmental Consultants, Inc. La Habra High School – Aquatics Facility Comprehensive Asbestos and Lead-Based Paint XRF Survey Report March 11, 2020

Page 5

1.1 Asbestos Findings A total of sixty (60) bulk samples were collected for laboratory analysis. Some of these samples were separated [by the laboratory] by individual layers to determine a more accurate analysis. Therefore, the total number of the samples analyzed was seventy-one (71). All samples collected were submitted under the chain of custody protocol to LA Testing Laboratories Inc., located in Huntington Beach, California 92649. LA Testing is certified with the NVLAP registration (code: 101384-0) and approved for asbestos bulk sample analysis in the State of California. The sample analysis was performed by EPA Polarized Light Microscopy (PLM) coupled with dispersion staining, method 600/R-93/116, July 1993. All PLM analyses are derived from a calibrated visual estimate unless otherwise noted. The following materials were inaccessible for testing and determined to be presumed asbestos-containing materials (PACM) at >1%: Aquatics Facility: Presumed Asbestos-Containing Materials

In the event that other suspect building materials (not included in this survey report) are discovered and have the potential to be impacted or disturbed during construction, renovation and/or demolition activities; those suspect building materials will be considered asbestos-containing materials until a State Certified, Asbestos Consultant is retained to determine asbestos content of those materials. Federal regulations define asbestos-containing material (ACM) as any material that contains more than one percent (>1%) asbestos. State Cal/OSHA-California Labor Code, Section 6501.8 defines “asbestos containing construction material (ACCM)” as any manufactured construction material that contains more than one tenth of one percent (>0.1%) asbestos by weight.

Sample No.

Sample Location

Sample Description Color Material

Condition

Friable Non-

Friable

Material Location

Approx. Quantity

Laboratory Results

PACM- 61. Inside Pool Pool Basin

Plaster White Good Non-Friable

Pool Basin throughout

Pool

1,000 Sq. Ft.

PACM/ >1% ACM

(Inaccessible for Testing)

PACM – 62. Pool Trim Concrete

Coping Multi Good Non-Friable

Concrete Coping

around Pool Trim

250 Sq. Ft.

PACM/ >1% ACM

(Inaccessible for Testing)

Page 6: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

Fullerton Joint Union High School District Bainbridge Environmental Consultants, Inc. La Habra High School – Aquatics Facility Comprehensive Asbestos and Lead-Based Paint XRF Survey Report March 11, 2020

Page 6

1.2 Asbestos Recommendations Based on the available information gathered during the performance of this survey and its conclusions, Bainbridge recommends the following:

• Identified presumed and/or asbestos-containing materials must be removed prior to the scheduled demolition activities in adherence with South Coast Air Quality Management District (SCAQMD) regulations (Rule 1403).

• Bainbridge recommends the preparation of project specifications for the removal of

identified presumed and/or asbestos-containing materials and/or Cal/OSHA regulated asbestos-containing construction materials (samples greater than .1% asbestos), as necessary. A State of California Certified Asbestos Consultant should be retained to properly document, inspect, and monitor the removal of any identified and/or assumed asbestos-containing materials. This is to ensure adherence to applicable State and Federal regulations and for the safety of building occupants in the vicinity of the abatement areas.

• Bainbridge recommends that a Cal/OSHA registered and State licensed abatement

contracting company perform the abatement of the above-mentioned presumed and/or asbestos-containing materials. Any asbestos related work must be conducted in accordance with all applicable Federal, State, and local regulations. Firms performing the asbestos-related work must follow proper engineering practices and must use state-of-the-art techniques as outlined in Bainbridge’s Asbestos Abatement Project Specifications Section 02080 – Asbestos Abatement.

1.3 Disclaimer and Limitations for Asbestos Related Projects This document is prepared for the sole use of the Fullerton Joint Union High School District and its authorized representatives and any agencies directly involved in this project. No other party should rely on the information contained herein without prior written consent of Bainbridge. The information in this report or portions thereof may be required to be included in notifications to employees, contractors or other visitors to the building. The Fullerton Joint Union High School District or its agents shall not use this report as a specification or work plan for any of the work suggested or recommended in the report. This report is based upon conditions and practices observed at the property and information made available to Bainbridge. This report does not identify all hazards or unsafe practices, nor does it indicate that other hazards or unsafe practices exist at the premises. The conclusions and summary presented in this report are based on a review of pertinent regulations, and guidelines or requirements commonly followed by industry standards, data collected during the site inspection, and information provided by the Fullerton Joint Union High School District, their clients, agents, and representatives. The work has been conducted in an objective and unbiased manner and in accordance with generally accepted professional practice for this type of work. Bainbridge believes the data and analysis to be accurate and relevant but cannot accept responsibility for the accuracy or completeness of available documentation or possible withholding of information by other parties. Any observations of asbestos containing materials represent the conditions at the specified locations and times of the site inspection survey only.

Page 7: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

Fullerton Joint Union High School District Bainbridge Environmental Consultants, Inc. La Habra High School – Aquatics Facility Comprehensive Asbestos and Lead-Based Paint XRF Survey Report March 11, 2020

Page 7

2.0 Lead-Based Paint XRF Testing of Painted Surfaces Marco Silva, CDPH Certified Lead-Related Construction, Sampling Technician, under the direction of Karlin Cisco, CDPH Certified Lead-Related Construction, Inspector Assessor of Bainbridge, performed the comprehensive survey activities and collected the lead-based paint XRF readings at La Habra High School - Aquatics Facility located at 801 Highlander Avenue, La Habra, California 90631. The purpose of the survey was to identify any suspect lead-containing building materials that are scheduled to be impacted or disturbed during an upcoming/scheduled pool alteration project. The survey was performed on the date of March 4, 2020 and consisted of collection of XRF readings of suspect lead-based painted building materials in the Aquatics Facility. This report reviews and summarizes the findings outlined in the attached lead-based paint XRF sampling log with analytical results. Bainbridge conducted the lead-based paint survey of the subject Aquatics Facility in compliance with the following Federal, State, and Local regulations: • 24 CFR Part 35.80-35.98 and 35.3120(b) – U.S. Department of Housing and Urban

Development (HUD) • Toxic Substances Control Act (TOSCA) Section 406 • 40 CFR 745.103 – Environmental Protection Agency (EPA) • Title 17 Section 35000 – Code of California Regulations • Cal/OSHA Title 8 Section 1532.1 – California Occupational Safety and Health Administration • Cal/OSHA Title 8 Section 5194 – California Occupational Safety and Health Administration Currently, the State of California, the U.S. Department of Housing and Urban Development (HUD), and the Environmental Protection Agency (EPA) define lead-based paint as paint or other surface coating with lead content equal to or greater than 1.0 milligrams per square centimeter (mg/cm2), 0.5% by weight, and/or 5,000 parts per million (ppm) lead on the surface area. XRF Paint Readings: XRF measurements were collected. Bainbridge conducted this comprehensive survey using a Viken PB200i Analyzer, X-ray Fluorescence (XRF) detector. All survey activities and XRF measurements were performed in accordance with the United States Department of Housing and Urban Development’s guidance document, entitled “Guidelines for the Evaluation and Control of Lead-based Paint Hazards in Housing: Chapter 7 Lead-based paint inspection”. The XRF Lead Sampling Logs are provided as an attachment to this survey/inspection report. These logs tabulate each individual test, sample taken throughout the subject areas and describes the test location, the component to which the paint is applied, condition, color and lead content in milligrams per square centimeter and the result. In the event that other materials are found to be similar or homogenous to the materials sampled, those similar or homogenous materials will be considered lead-containing materials. Prior to bid, contractor is responsible for field verification of those materials, their quantities and measurements.

Page 8: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

Fullerton Joint Union High School District Bainbridge Environmental Consultants, Inc. La Habra High School – Aquatics Facility Comprehensive Asbestos and Lead-Based Paint XRF Survey Report March 11, 2020

Page 8

2.1 Lead-Based Paint XRF Findings XRF Testing: A total of sixty (60) XRF readings were collected. The field data and results of the XRF testing are included in Appendix B of this report. As a result of lead-based paint XRF testing, the following materials were determined to contain lead-based paint: Aquatics Facility: Lead-Based Paint XL No Side Bldg Room Source Substrate Color

Results Positive Negative

Approx. Quantity mg/cm2

30 A Aquatic Facility

Pool Area Pool Trim Concrete Red 2.1 Positive 7

Sq. Ft.

31 C Aquatic Facility

Pool Area Pool Trim Concrete Red 1.4 Positive See

XL No 30

35 B Aquatic Facility

Pool Area

Pool Interior

Wall Lining Concrete White 1.0 Positive 5,929

Sq. Ft.

36 B Aquatic Facility

Pool Area

Pool Interior

Wall Lining Concrete White 9.0 Positive See

XL No 35

37 C Aquatic Facility

Pool Area

Pool Interior

Wall Lining Concrete White 3.8 Positive See

XL No 35

38 D Aquatic Facility

Pool Area

Pool Interior

Wall Lining Concrete White 8.8 Positive See

XL No 35

39 D Aquatic Facility

Pool Area

Pool Interior

Wall Lining Concrete White 8.7 Positive See

XL No 35

40 A Aquatic Facility

Pool Area

Pool Interior

Wall Lining Concrete White 8.1 Positive See

XL No 35

In the event that other suspect building materials (not included in this survey report) are discovered and have the potential to be impacted or disturbed during demolition activities; those suspect building materials will be considered lead-containing materials until a State Certified, Inspector/Assessor is retained to determine lead content of those materials.

Page 9: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

Fullerton Joint Union High School District Bainbridge Environmental Consultants, Inc. La Habra High School – Aquatics Facility Comprehensive Asbestos and Lead-Based Paint XRF Survey Report March 11, 2020

Page 9

2.2 Lead-Based Paint Recommendations Based on the available information gathered during the performance of this survey and its conclusions, Bainbridge recommends the following:

• The removal of the identified lead-based paint components from the subject aquatics facility prior to the demolition activities. Bainbridge recommends the utilization of a State licensed lead abatement contracting company to remove, transport and dispose of the identified lead-containing waste in according to applicable Federal and State regulations.

• The Occupational Safety and Health Administration (OSHA) promulgated legislation (29 CFR 1926.62 and 8 CCR1532.1) entitled "Lead Exposure in Construction Industry", requires that any job that may potentially expose workers to any concentration of lead (i.e., >0.01 mg/cm2) be monitored by the employer to determine workers eight-hour time weighted average (TWA) exposure to lead.

2.3 Disclaimer and Limitations for Lead-Based Paint and Components This document is prepared for the sole use of Fullerton Joint Union High School District and its authorized representatives and any agencies directly involved in this project. No other party should rely on the information contained herein without prior written consent of Bainbridge. The information in this report or portions thereof may be required to be included in notifications to employees, contractors or other visitors to the aquatics facility. Fullerton Joint Union High School District or its agents shall not use this report as a project specification or work plan for any of the work suggested or recommended in the report. This report is based upon conditions and practices observed at the property and information made available to Bainbridge. This report does not identify all hazards or unsafe practices, nor does it indicate that other hazards or unsafe practices exist at the premises. This inspection and assessment was planned, developed, and patterned after HUD Guidelines Chapter 7 Lead-based paint inspection. Bainbridge utilized state-of-the-art practices and techniques in accordance with regulatory standards while performing this inspection. Bainbridge’s evaluation of the relative risk of exposure to lead identified during this inspection is based on conditions observed at the time of the inspection. Bainbridge cannot be responsible for changing conditions that may alter the relative exposure risk or for future changes in accepted methodology. The conclusions and summary presented in this report are based on a review of pertinent regulations, and guidelines or requirements commonly followed by industry standards, data collected during the site inspection, and information provided by the District, their clients, agents, and representatives The work has been conducted in an objective and unbiased manner and in accordance with generally accepted professional practice for this type of work. Bainbridge believes the data and analysis to be accurate and relevant but cannot accept responsibility for the accuracy or completeness of available documentation or possible withholding of information by other parties.

Page 10: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

Fullerton Joint Union High School District Bainbridge Environmental Consultants, Inc. La Habra High School – Aquatics Facility Comprehensive Asbestos and Lead-Based Paint XRF Survey Report March 11, 2020

Page 10

Any observations of lead-based paint and lead containing materials represent the conditions at the specified locations and times of the site inspection survey only. The selection of sample areas was limited to accessible areas of the subject aquatics facility.

Page 11: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

Fullerton Joint Union High School District Bainbridge Environmental Consultants, Inc. La Habra High School – Aquatics Facility Comprehensive Asbestos and Lead-Based Paint XRF Survey Report March 11, 2020

Page 11

APPENDIX A

ASBESTOS FIELD DATA AND LABORATORY RESULTS

Page 12: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

1322 Bell Avenue, Suite 1N Tel (714) 247-0024 Tustin, CA 92780 1 of 5 Fax (714) 247-0025

Sample No.

Sample Location

Sample Description Color Material

Condition Friable

Non-Friable Material Location

Approx. Quantity

Laboratory Results

1. Co-Gen 260 - East Plaster White Good Non-Friable Plaster throughout Co-Gen 260

500 Sq. Ft.

None Detected

2. Co-Gen 260 - South Plaster White Good Non-Friable See Above Included Above

None Detected

3. Co-Gen 260 - East Plaster White Good Non-Friable See Above Included Above

None Detected

4. Co-Gen 260 - West Concrete Wall White Good Non-Friable Concrete Walls &

Ceiling throughout Co-Gen 260

900 Sq. Ft.

None Detected

5. Co-Gen 260 - Ceiling Concrete Ceiling White Good Non-Friable See Above Included Above

None Detected

6. Co-Gen 260 - North Concrete Wall White Good Non-Friable See Above Included Above

None Detected

7. Co-Gen 260 - South Concrete Floor White Good Non-Friable Concrete Floor

throughout Co-Gen 260

450 Sq. Ft.

None Detected

8. Co-Gen 260 - South Concrete Floor White Good Non-Friable See Above Included Above

None Detected

9. Co-Gen 260 - Center Concrete Floor White Good Non-Friable See Above Included Above

None Detected

10. Co-Gen 260 - South Fiberglass Pipe Insulation Pink Good Friable

Fiberglass Pipe Insulation

throughout Co-Gen 260

300 Sq. Ft.

None Detected

Client: FJUHSD Bainbridge Project #: 20027913.13

Project Name: La Habra High School – Aquatics Facility Inspector/Sampler: Marco Silva

Address: 801 Highlander Avenue Date Sampled: 3/4 & 3/5/2020

La Habra, California 90631

ASBESTOS BULK SAMPLE LOG

Page 13: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

ASBESTOS BULK SAMPLE LOG FJUHSD – La Habra High School – Aquatics Facility - 801 Highlander Avenue, La Habra, California 90631

1322 Bell Avenue, Suite 1N Tel (714) 247-0024 Tustin, CA 92780 2 of 5 Fax (714) 247-0025

Sample No.

Sample Location

Sample Description Color Material

Condition Friable

Non-Friable Material Location

Approx. Quantity

Laboratory Results

11. Co-Gen 260 - Center Fiberglass Pipe Insulation Yellow Good Friable See Above Included Above

None Detected

12. Co-Gen 260 - Center Fiberglass Pipe Insulation Yellow Good Friable See Above Included Above

None Detected

13. Co-Gen 260 - Center Cloth Jacket White Good Friable Cloth Jacket throughout Co-Gen 260

10 Sq. Ft.

None Detected

14. Co-Gen 260 - Center Cloth Jacket White Good Friable See Above Included Above

None Detected

15. Co-Gen 260 - Center Cloth Jacket White Good Friable See Above Included Above

None Detected

16. Co-Gen 260 - North Water Heater Tank Insulation Black Good Friable

Water Heater Tank Insulation

throughout Co-Gen 260

10 Sq. Ft.

None Detected

17. Co-Gen 260 - North Water Heater Tank Insulation Black Good Friable See Above Included

Above None

Detected

18. Co-Gen 260 - North Water Heater Tank Insulation Black Good Friable See Above Included

Above None

Detected

19. Co-Gen 260 - Exterior North Pavement Black Good Non-Friable

Pavement throughout Co-Gen 260

2,500 Sq. Ft.

None Detected

20. Co-Gen 260 - Exterior North Pavement Black Good Non-Friable See Above Included

Above None

Detected

21. Co-Gen 260 - Exterior North Pavement Black Good Non-Friable See Above Included

Above None

Detected

22. Pool Area Concrete Floor Gray Good Non-Friable Concrete Floor

throughout Pool Area

5,000 Sq. Ft.

None Detected

23. Pool Area Concrete Floor Gray Good Non-Friable See Above Included Above

None Detected

Page 14: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

ASBESTOS BULK SAMPLE LOG FJUHSD – La Habra High School – Aquatics Facility - 801 Highlander Avenue, La Habra, California 90631

1322 Bell Avenue, Suite 1N Tel (714) 247-0024 Tustin, CA 92780 3 of 5 Fax (714) 247-0025

Sample No.

Sample Location

Sample Description Color Material

Condition Friable

Non-Friable Material Location

Approx. Quantity

Laboratory Results

24. Pool Area Concrete Floor Gray Good Non-Friable See Above Included Above

None Detected

25. Pool Area - West Concrete Wall White Good Non-Friable Concrete Wall

throughout Pool Area

1,000 Sq. Ft.

None Detected

26. Pool Area - West Concrete Wall White Good Non-Friable See Above Included Above

None Detected

27. Pool Area - West Concrete Wall White Good Non-Friable See Above Included Above

None Detected

28. Pool Area - West CMU Wall Blue Good Non-Friable CMU Wall

throughout Pool Area

1,500 Sq. Ft.

None Detected

29. Pool Area - West CMU Wall Blue Good Non-Friable See Above Included Above

None Detected

30. Pool Area - West CMU Wall Blue Good Non-Friable See Above Included Above

None Detected

31. Acid Room – East Concrete Wall Gray Good Non-Friable Concrete Wall

Throughout Acid Room

375 Sq. Ft.

None Detected

32. Acid Room – East Concrete Wall Gray Good Non-Friable See Above Included Above

None Detected

33. Acid Room – East Concrete Wall Gray Good Non-Friable See Above Included Above

None Detected

34. Acid Room - Center Concrete Floor Gray Good Non-Friable Concrete Floor

Throughout Acid Room

450 Sq. Ft.

None Detected

35. Acid Room - Center Concrete Floor Gray Good Non-Friable See Above Included Above

None Detected

36. Acid Room - Center Concrete Floor Gray Good Non-Friable See Above Included Above

None Detected

Page 15: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

ASBESTOS BULK SAMPLE LOG FJUHSD – La Habra High School – Aquatics Facility - 801 Highlander Avenue, La Habra, California 90631

1322 Bell Avenue, Suite 1N Tel (714) 247-0024 Tustin, CA 92780 4 of 5 Fax (714) 247-0025

Sample No.

Sample Location

Sample Description Color Material

Condition Friable

Non-Friable Material Location

Approx. Quantity

Laboratory Results

37. Co-Gen 260 Roof - West Rolled Roofing White Good Non-Friable

Rolled Roofing throughout

Co-Gen 260 Roof

2000 Sq. Ft.

None Detected

38. Co-Gen 260 Roof - Center Rolled Roofing White Good Non-Friable See Above Included

Above None

Detected

39. Co-Gen 260 Roof - East Rolled Roofing White Good Non-Friable See Above Included

Above None

Detected

40. Co-Gen 260 Lower Roof - West Shingle Roofing Gray Good Non-Friable

Shingle Roofing throughout Co-Gen

260 Lower Roof

650 Sq. Ft.

None Detected

41. Co-Gen 260 Lower Roof - Center Shingle Roofing Gray Good Non-Friable See Above Included

Above None

Detected

42. Co-Gen 260 Lower Roof - East Shingle Roofing Gray Good Non-Friable See Above Included

Above None

Detected

43. Co-Gen 260 Roof - Center Pipe Mastic White Good Non-Friable

Pipe Mastic throughout

Co-Gen 260 Roof

35 Sq. Ft.

None Detected

44. Co-Gen 260 Roof - East Pipe Mastic White Good Non-Friable See Above Included

Above None

Detected

45. Co-Gen 260 Roof - West Pipe Mastic White Good Non-Friable See Above Included

Above None

Detected

46. Co-Gen 260 Roof - West Curb Mastic White Good Non-Friable

Curb Mastic throughout

Co-Gen 260 Roof

80 Sq. Ft.

None Detected

47. Co-Gen 260 Roof - Center Curb Mastic White Good Non-Friable See Above Included

Above None

Detected

48. Co-Gen 260 Roof - East Curb Mastic White Good Non-Friable See Above Included

Above None

Detected

49. Co-Gen 260 Roof - West HVAC Mastic White Good Non-Friable

HVAC Mastic throughout

Co-Gen 260 Roof

30 Sq. Ft.

None Detected

Page 16: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

ASBESTOS BULK SAMPLE LOG FJUHSD – La Habra High School – Aquatics Facility - 801 Highlander Avenue, La Habra, California 90631

1322 Bell Avenue, Suite 1N Tel (714) 247-0024 Tustin, CA 92780 5 of 5 Fax (714) 247-0025

Sample No.

Sample Location

Sample Description Color Material

Condition Friable

Non-Friable Material Location

Approx. Quantity

Laboratory Results

50. Co-Gen 260 Roof - Center HVAC Mastic White Good Non-Friable See Above Included

Above None

Detected

51. Co-Gen 260 Roof - East HVAC Mastic White Good Non-Friable See Above Included

Above None

Detected

52. Co-Gen 260 Roof - North Perimeter Mastic White Good Non-Friable

Perimeter Mastic throughout

Co-Gen 260 Roof

120 Sq. Ft.

None Detected

53. Co-Gen 260 Roof - East Perimeter Mastic White Good Non-Friable See Above Included

Above None

Detected

54. Co-Gen 260 Roof - West Perimeter Mastic White Good Non-Friable See Above Included

Above None

Detected

55. Co-Gen 260 Roof - Center Vibration Damper Black Good Non-Friable

Vibration Damper throughout

Co-Gen 260 Roof

10 Sq. Ft.

None Detected

56. Co-Gen 260 Roof - East Vibration Damper Black Good Non-Friable See Above Included

Above None

Detected

57. Co-Gen 260 Roof – West Vibration Damper Black Good Non-Friable See Above Included

Above None

Detected

58. Acid Room – East Concrete Wall Green Good Non-Friable Concrete Wall

throughout Acid Room

400 Sq. Ft.

None Detected

59. Acid Room – East Concrete Wall Green Good Non-Friable See Above Included Above

None Detected

60. Acid Room – SoutH Concrete Wall Green Good Non-Friable See Above Included Above

None Detected

PACM- 61. Inside Pool Pool Basin Plaster White Good Non-Friable Pool Basin

throughout Pool 1,000 Sq. Ft.

PACM/ >1% ACM

PACM – 62. Pool Trim Concrete Coping Multi Good Non-Friable Concrete Coping

around Pool Trim 250

Sq. Ft. PACM/

>1% ACM

Page 17: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

LA Testing5431 Industrial Drive Huntington Beach, CA 92649

Tel/Fax: (714) 828-4999 / (714) 828-4944

http://www.LATesting.com / [email protected]

332004730LA Testing Order:

Customer ID: 32BAIN21

Customer PO:

Project ID:

Attention: Phone:Karlin Cisco (714) 403-7191

Fax:Bainbridge Environmental Consultants (714) 247-0025

Received Date:1322 Bell Avenue 03/07/2020 11:35 AM

Analysis Date:Suite 1N 03/10/2020

Collected Date:Tustin, CA 92780 03/04/2020

Project: La Habra HS/ Aquatic facility

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

1

332004730-0001

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Co-gen 260- East -

Plaster

2

332004730-0002

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Co-gen 260- South -

Plaster

3

332004730-0003

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Co-gen 260- East -

Plaster

4

332004730-0004

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Co-gen 260- West -

Concrete wall

5

332004730-0005

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Co-gen 260- Ceiling -

Concrete ceiling

6

332004730-0006

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Co-gen 260- North -

Concrete wall

7

332004730-0007

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Co-gen 260- South -

Concrete floor

8

332004730-0008

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Co-gen 260- South -

Concrete floor

9

332004730-0009

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Co-gen 260- Center -

Concrete floor

10

332004730-0010

None DetectedNon-fibrous (Other)12%Glass88%Silver/Pink

Fibrous

Heterogeneous

Co-gen 260- South -

Fiber glass pipe

insulation

11

332004730-0011

None DetectedNon-fibrous (Other)2%Glass98%Yellow

Fibrous

Homogeneous

Co-gen 260- Center -

Fiber glass pipe

insulation

12

332004730-0012

None DetectedNon-fibrous (Other)25%Glass75%White/Yellow

Fibrous

Heterogeneous

Co-gen 260- Center -

Fiber glass pipe

insulation

13

332004730-0013

None DetectedNon-fibrous (Other)2%Glass98%White/Purple

Fibrous

Homogeneous

Co-gen 260- Center -

Cloth jacket

14

332004730-0014

None DetectedNon-fibrous (Other)2%Glass98%White/Purple

Fibrous

Homogeneous

Co-gen 260- Center -

Cloth jacket

15

332004730-0015

None DetectedNon-fibrous (Other)2%Glass98%White/Purple

Fibrous

Homogeneous

Co-gen 260- Center -

Cloth jacket

16-Insulation 1

332004730-0016

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Co-gen 260- North -

Water heater tank

insulation

Initial report from: 03/10/2020 18:07:20

Page 1 of 5ASB_PLM_0008_0001 - 1.78 Printed: 3/10/2020 3:07 PM

Page 18: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

LA Testing5431 Industrial Drive Huntington Beach, CA 92649

Tel/Fax: (714) 828-4999 / (714) 828-4944

http://www.LATesting.com / [email protected]

332004730LA Testing Order:

Customer ID: 32BAIN21

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

16-Insulation 2

332004730-0016A

None DetectedNon-fibrous (Other)100%Black/Yellow

Non-Fibrous

Heterogeneous

Co-gen 260- North -

Water heater tank

insulation

17

332004730-0017

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Co-gen 260- North -

Water heater tank

insulation

18

332004730-0018

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Co-gen 260- North -

Water heater tank

insulation

19

332004730-0019

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Co-gen 260- Exterior

North - Pavement

20

332004730-0020

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Co-gen 260- Exterior

North - Pavement

21

332004730-0021

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Co-gen 260- Exterior

North - Pavement

22

332004730-0022

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Pool area - Concrete

floor

23

332004730-0023

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Pool area - Concrete

floor

24

332004730-0024

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Pool area - Concrete

floor

25-Concrete

332004730-0025

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Pool area - West -

Concrete wall

25-Caulk

332004730-0025A

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Pool area - West -

Concrete wall

26

332004730-0026

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Pool area - West -

Concrete wall

27

332004730-0027

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Pool area - West -

Concrete wall

28

332004730-0028

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Pool area - West -

CMU wall

29

332004730-0029

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Pool area - West -

CMU wall

30

332004730-0030

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Pool area - West -

CMU wall

31

332004730-0031

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Acid room - East -

Concrete wall

32

332004730-0032

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Acid room - East -

Concrete wall

33

332004730-0033

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Acid room - East -

Concrete wall

Initial report from: 03/10/2020 18:07:20

Page 2 of 5ASB_PLM_0008_0001 - 1.78 Printed: 3/10/2020 3:07 PM

Page 19: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

LA Testing5431 Industrial Drive Huntington Beach, CA 92649

Tel/Fax: (714) 828-4999 / (714) 828-4944

http://www.LATesting.com / [email protected]

332004730LA Testing Order:

Customer ID: 32BAIN21

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

34

332004730-0034

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Acid room - Center -

Concrete floor

35

332004730-0035

None DetectedNon-fibrous (Other)100%Tan

Non-Fibrous

Homogeneous

Acid room - Center -

Concrete floor

36

332004730-0036

None DetectedNon-fibrous (Other)100%Tan

Non-Fibrous

Homogeneous

Acid room - Center -

Concrete floor

37

332004730-0037

None DetectedNon-fibrous (Other)92%Glass8%White/Black

Fibrous

Heterogeneous

Co-gen 260 Roof -

West - Rolled roofing

38

332004730-0038

None DetectedNon-fibrous (Other)92%Glass8%White/Black

Fibrous

Heterogeneous

Co-gen 260 Roof -

Center - Rolled

roofing

39

332004730-0039

None DetectedNon-fibrous (Other)92%Glass8%White/Black

Fibrous

Heterogeneous

Co-gen 260 Roof -

East - Rolled roofing

40-Shingle

332004730-0040

None DetectedNon-fibrous (Other)92%Glass8%Gray/Black

Fibrous

Heterogeneous

Co-gen 260 Lower

Roof - West - Shingle

roofing

40-Felt

332004730-0040A

None DetectedNon-fibrous (Other)50%Cellulose50%Black

Fibrous

Heterogeneous

Co-gen 260 Lower

Roof - West - Shingle

roofing

41-Shingle

332004730-0041

None DetectedNon-fibrous (Other)92%Glass8%Gray/Black

Fibrous

Heterogeneous

Co-gen 260 Lower

Roof - Center -

Shingle roofing

41-Felt

332004730-0041A

None DetectedNon-fibrous (Other)50%Cellulose50%Black

Fibrous

Heterogeneous

Co-gen 260 Lower

Roof - Center -

Shingle roofing

42-Shingle

332004730-0042

None DetectedNon-fibrous (Other)92%Glass8%Gray/Black

Fibrous

Heterogeneous

Co-gen 260 Lower

Roof - East - Shingle

roofing

42-Felt

332004730-0042A

None DetectedNon-fibrous (Other)50%Cellulose50%Black

Fibrous

Heterogeneous

Co-gen 260 Lower

Roof - East - Shingle

roofing

43

332004730-0043

None DetectedNon-fibrous (Other)88%Cellulose

Glass

10%

2%

White/Black

Fibrous

Heterogeneous

Co-gen 260 Roof -

Center - Pipe mastic

44

332004730-0044

None DetectedNon-fibrous (Other)88%Cellulose

Glass

10%

2%

White/Black

Fibrous

Heterogeneous

Co-gen 260 Roof -

East - Pipe mastic

45

332004730-0045

None DetectedNon-fibrous (Other)88%Cellulose

Glass

10%

2%

White/Black

Fibrous

Heterogeneous

Co-gen 260 Roof -

West - Pipe mastic

46-Mastic

332004730-0046

None DetectedNon-fibrous (Other)87%Cellulose

Glass

10%

3%

White/Black

Fibrous

Heterogeneous

Co-gen 260 Roof -

West - Curb mastic

46-Shingle

332004730-0046A

None DetectedNon-fibrous (Other)90%Glass10%Gray/Black

Fibrous

Heterogeneous

Co-gen 260 Roof -

West - Curb mastic

47-Mastic

332004730-0047

None DetectedNon-fibrous (Other)87%Cellulose

Glass

10%

3%

White/Black

Fibrous

Heterogeneous

Co-gen 260 Roof -

Center - Curb mastic

47-Shingle

332004730-0047A

None DetectedNon-fibrous (Other)92%Glass8%Gray/Black

Fibrous

Heterogeneous

Co-gen 260 Roof -

Center - Curb mastic

Initial report from: 03/10/2020 18:07:20

Page 3 of 5ASB_PLM_0008_0001 - 1.78 Printed: 3/10/2020 3:07 PM

Page 20: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

LA Testing5431 Industrial Drive Huntington Beach, CA 92649

Tel/Fax: (714) 828-4999 / (714) 828-4944

http://www.LATesting.com / [email protected]

332004730LA Testing Order:

Customer ID: 32BAIN21

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

47-Felt

332004730-0047B

None DetectedNon-fibrous (Other)82%Synthetic18%Black

Fibrous

Homogeneous

Co-gen 260 Roof -

Center - Curb mastic

48-Mastic

332004730-0048

None DetectedNon-fibrous (Other)89%Cellulose

Glass

8%

3%

White/Black

Fibrous

Heterogeneous

Co-gen 260 Roof -

East - Curb mastic

48-Shingle

332004730-0048A

None DetectedNon-fibrous (Other)90%Glass10%Gray/Black

Fibrous

Heterogeneous

Co-gen 260 Roof -

East - Curb mastic

48-Insulation

332004730-0048B

None DetectedNon-fibrous (Other)40%Cellulose60%Tan

Fibrous

Homogeneous

Co-gen 260 Roof -

East - Curb mastic

49

332004730-0049

None DetectedNon-fibrous (Other)92%Cellulose8%Black

Fibrous

Homogeneous

Co-gen 260 Roof -

West - HVAC mastic

50-Mastic 1

332004730-0050

None DetectedNon-fibrous (Other)92%Cellulose8%Black

Fibrous

Homogeneous

Co-gen 260 Roof -

Center - HVAC mastic

50-Mastic 2

332004730-0050A

None DetectedNon-fibrous (Other)100%Gray/White

Non-Fibrous

Heterogeneous

Co-gen 260 Roof -

Center - HVAC mastic

51

332004730-0051

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Co-gen 260 Roof -

East - HVAC mastic

52

332004730-0052

None DetectedNon-fibrous (Other)98%Synthetic2%White/Black

Non-Fibrous

Heterogeneous

Co-gen 260 Roof -

North - Perimeter

mastic

53

332004730-0053

None DetectedNon-fibrous (Other)98%Synthetic2%White/Black

Non-Fibrous

Heterogeneous

Co-gen 260 Roof -

East - Perimeter

mastic

54

332004730-0054

None DetectedNon-fibrous (Other)98%Synthetic2%White/Black

Non-Fibrous

Heterogeneous

Co-gen 260 Roof -

West - Perimeter

mastic

55

332004730-0055

None DetectedNon-fibrous (Other)80%Synthetic20%Black

Fibrous

Homogeneous

Co-gen 260 Roof -

Center - Vibration

damper

56

332004730-0056

None DetectedNon-fibrous (Other)80%Synthetic20%Black

Fibrous

Homogeneous

Co-gen 260 Roof -

East - Vibration

damper

57

332004730-0057

None DetectedNon-fibrous (Other)80%Synthetic20%Black

Fibrous

Homogeneous

Co-gen 260 Roof -

West - Vibration

damper

58

332004730-0058

None DetectedNon-fibrous (Other)100%Gray/Green

Non-Fibrous

Heterogeneous

Acid room - East -

Concrete wall

59

332004730-0059

None DetectedNon-fibrous (Other)100%Gray/Green

Non-Fibrous

Heterogeneous

Acid room - East -

Concrete wall

60

332004730-0060

None DetectedNon-fibrous (Other)100%Gray/Green

Non-Fibrous

Heterogeneous

Acid room - South -

Concrete wall

Initial report from: 03/10/2020 18:07:20

Page 4 of 5ASB_PLM_0008_0001 - 1.78 Printed: 3/10/2020 3:07 PM

Page 21: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

LA Testing5431 Industrial Drive Huntington Beach, CA 92649

Tel/Fax: (714) 828-4999 / (714) 828-4944

http://www.LATesting.com / [email protected]

332004730LA Testing Order:

Customer ID: 32BAIN21

Customer PO:

Project ID:

Analyst(s)

Brittany Quiring (53)

Monica Luna (18)

Michael DeCavallas, Laboratory Manager

or Other Approved Signatory

EMSL maintains liability limited to cost of analysis . The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 "Interim

Method"), but augmented with procedures outlined in the 1993 ("final") version of the method. This report relates only to the samples reported above, and may not be reproduced, except in full, without

written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations . Interpretation and use of test results are the responsibility of the client. All

samples received in acceptable condition unless otherwise noted. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of

the federal government. EMSL recommends gravimetric reduction for all non -friable organically bound materials prior to analysis. Estimation of uncertainty is available on request.

Samples analyzed by LA Testing Huntington Beach, CA NVLAP Lab Code 101384-0, CA ELAP 1406

Initial report from: 03/10/2020 18:07:20

Page 5 of 5ASB_PLM_0008_0001 - 1.78 Printed: 3/10/2020 3:07 PM

Page 22: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

OrderID: 332004730

Page 1 Of 9

Page 23: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

Fullerton Joint Union High School District Bainbridge Environmental Consultants, Inc. La Habra High School – Aquatics Facility Comprehensive Asbestos and Lead-Based Paint XRF Survey Report March 11, 2020

Page 12

APPENDIX B

LEAD-BASED PAINT XRF FIELD DATA AND ANALYTICAL RESULTS

Page 24: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

1322 Bell Avenue, Suite 1N Tel (714) 247-0024 Tustin, CA 92780 1 of 5 Fax (714) 247-0025

XL No Side Building Room Source Substrate Color Results Positive Approx. mg/cm2 Negative Quantity

1 N/A Calibration Calibration Calibration Wood Green 1.0 Positive Time: 5:50 am

2 N/A Calibration Calibration Calibration Wood Green 0.9 Negative Time: 5:50 am

3 N/A Calibration Calibration Calibration Wood Green 1.0 Positive Time: 5:51 am

4 A Aquatic Facility Co-Gen 260 Wall Plaster White 0.0 Negative N/A

5 B Aquatic Facility Co-Gen 260 Wall Plaster White -0.1 Negative N/A

6 C Aquatic Facility Co-Gen 260 Wall Concrete White 0.1 Negative N/A

7 D Aquatic Facility Co-Gen 260 Wall Concrete White 0.2 Negative N/A

8 D Aquatic Facility Co-Gen 260 Door Frame Metal Gray -0.1 Negative N/A

9 D Aquatic Facility Co-Gen 260 Door (Interior) Wood Blue -0.1 Negative N/A

10 D Aquatic Facility Co-Gen 260 Door (Exterior) Wood Blue 0.0 Negative N/A

11 C Aquatic Facility Co-Gen 260 Pipe Run Metal White 0.1 Negative N/A

12 C Aquatic Facility Co-Gen 260 Pipe Run Metal White 0.1 Negative N/A

13 A Aquatic Facility Co-Gen 260 Pipe Run Metal Green 0.1 Negative N/A

Client: FJUHSD Client Project #: N/A

Site: La Habra High School – Aquatics Facility Bainbridge Project #: 20027913.13

Address: 801 Highland Avenue Inspector/Sampler: Marco Silva

La Habra, California 90631 Date Sampled: 3/4/2020

Lead-Based Paint XRF Sampling Log

Page 25: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

XRF Lead-Based Paint Sampling Log

FJUHSD – La Habra High School – Aquatics Facility - 801 Highlander Avenue, La Habra, California 90631

1322 Bell Avenue, Suite 1N Tel (714) 247-0024 Tustin, CA 92780 2 of 5 Fax (714) 247-0025

XL No Side Building Room Source Substrate Color Results Positive Approx. mg/cm2 Negative Quantity

14 C Aquatic Facility Co-Gen 260 EMS Control Panel #1 Metal Gray 0.0 Negative N/A

15 C Aquatic Facility Co-Gen 260 Floor Concrete Gray 0.3 Negative N/A

16 D Aquatic Facility Co-Gen 260 (Exterior) Wall Concrete Gray/

Blue 0.1 Negative N/A

17 A Aquatic Facility Co-Gen 260 (Exterior) Wall Concrete Gray/

Blue 0.0 Negative N/A

18 B Aquatic Facility Co-Gen 260 (Exterior) Wall Concrete Gray/

Blue 0.3 Negative N/A

19 C Aquatic Facility Co-Gen 260 (Exterior) Wall Concrete Gray/

Blue 0.2 Negative N/A

20 C Aquatic Facility Acid Room Louver Metal Gray/

Blue 0.5 Negative N/A

21 C Aquatic Facility Acid Room Louver Metal Gray/

Blue 0.5 Negative N/A

22 C Aquatic Facility Acid Room Electrical Conduit Metal Gray/

Blue 0.0 Negative N/A

23 C Aquatic Facility Acid Room Electrical Conduit Metal Gray/

Blue -0.6 Negative N/A

24 C Aquatic Facility Acid Room Electrical Panel Metal Gray/

Blue 0.1 Negative N/A

25 A Aquatic Facility Acid Room Wall Concrete Green 0.8 Negative N/A

26 D Aquatic Facility Acid Room Wall Concrete Green 0.5 Negative N/A

27 B Aquatic Facility Acid Room Wall Concrete Green 0.6 Negative N/A

28 B Aquatic Facility

Pool Area Pool Trim Concrete Blue 0.2 Negative N/A

Page 26: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

XRF Lead-Based Paint Sampling Log

FJUHSD – La Habra High School – Aquatics Facility - 801 Highlander Avenue, La Habra, California 90631

1322 Bell Avenue, Suite 1N Tel (714) 247-0024 Tustin, CA 92780 3 of 5 Fax (714) 247-0025

XL No Side Building Room Source Substrate Color Results Positive Approx. mg/cm2 Negative Quantity

29 B Aquatic Facility Pool Area Pool Trim Concrete White 0.2 Negative N/A

30 A Aquatic Facility Pool Area Pool Trim Concrete Red 2.1 Positive 7

Sq. Ft.

31 C Aquatic Facility Pool Area Pool Trim Concrete Red 1.4 Positive See 30

32 C Aquatic Facility Pool Area Pool Trim Concrete Yellow 0.1 Negative N/A

33 C Aquatic Facility Pool Area Pool Trim Concrete Blue 0.4 Negative N/A

34 C Aquatic Facility Pool Area Lifeguard Chair Metal Blue 0.1 Negative N/A

35 B Aquatic Facility Pool Area Pool Interior Wall Lining Concrete White 1.0 Positive 5,929

Sq. Ft.

36 B Aquatic Facility Pool Area Pool Interior Wall Lining Concrete White 9.0 Positive See 35

37 C Aquatic Facility Pool Area Pool Interior Wall Lining Concrete White 3.8 Positive See 35

38 D Aquatic Facility Pool Area Pool Interior Wall Lining Concrete White 8.8 Positive See 35

39 D Aquatic Facility Pool Area Pool Interior Wall Lining Concrete White 8.7 Positive See 35

40 A Aquatic Facility Pool Area Pool Interior Wall Lining Concrete White 8.1 Positive See 35

41 B Aquatic Facility Pool Area Bleachers Wood Blue 0.1 Negative N/A

42 B Aquatic Facility Pool Area Bleachers Wood Blue 0.0 Negative N/A

43 B Aquatic Facility Pool Area Bleachers Wood Blue 0.0 Negative N/A

Page 27: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

XRF Lead-Based Paint Sampling Log

FJUHSD – La Habra High School – Aquatics Facility - 801 Highlander Avenue, La Habra, California 90631

1322 Bell Avenue, Suite 1N Tel (714) 247-0024 Tustin, CA 92780 4 of 5 Fax (714) 247-0025

XL No Side Building Room Source Substrate Color Results Positive Approx. mg/cm2 Negative Quantity

44 C Aquatic Facility Pool Area Wall Concrete White 0.2 Negative N/A

45 C Aquatic Facility Pool Area Wall Concrete White 0.3 Negative N/A

46 C Aquatic Facility Pool Area Wall Concrete White 0.2 Negative N/A

47 C Aquatic Facility Pool Area Wall Concrete White 0.4 Negative N/A

48 C Aquatic Facility Pool Area Brick & Mortar Brick Blue 0.1 Negative N/A

49 C Aquatic Facility Pool Area Brick & Mortar Brick Blue 0.1 Negative N/A

50 C Aquatic Facility Pool Area Brick & Mortar Brick Blue 0.0 Negative N/A

51 C Aquatic Facility Pool Area Brick & Mortar Brick Blue 0.3 Negative N/A

52 C Aquatic Facility Pool Area Diving Board Metal White -0.4 Negative N/A

53 C Aquatic Facility Pool Area Diving Board Metal White 0.1 Negative N/A

54 D Aquatic Facility Co-Gen 260 Roof Fascia Board Wood Blue 0.0 Negative N/A

55 D Aquatic Facility Co-Gen 260 Roof Fascia Board Metal Blue 0.1 Negative N/A

56 A Aquatic Facility Roof Rolled Roofing Wood White -0.1 Negative N/A

57 C Aquatic Facility Roof Fascia Board Concrete Blue 0.2 Negative N/A

58 N/A Calibration Calibration Calibration N/A Green 1.0 Positive Time: 9:55 am

Page 28: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

XRF Lead-Based Paint Sampling Log

FJUHSD – La Habra High School – Aquatics Facility - 801 Highlander Avenue, La Habra, California 90631

1322 Bell Avenue, Suite 1N Tel (714) 247-0024 Tustin, CA 92780 5 of 5 Fax (714) 247-0025

XL No Side Building Room Source Substrate Color Results Positive Approx. mg/cm2 Negative Quantity

59 N/A Calibration Calibration Calibration N/A Green 1.0 Positive Time: 9:56 am

60 N/A Calibration Calibration Calibration N/A Green 1.0 Positive Time: 9:56 am

-END OF REPORT-

Page 29: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

Fullerton Joint Union High School District Bainbridge Environmental Consultants, Inc. La Habra High School – Aquatics Facility Comprehensive Asbestos and Lead-Based Paint XRF Survey Report March 11, 2020

Page 13

APPENDIX C

ASBESTOS AND LEAD-BASED PAINT INSPECTOR’S STATE CERTIFICATIONS

Page 30: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

Fullerton Joint Union High School District Bainbridge Environmental Consultants, Inc. La Habra High School – Aquatics Facility Comprehensive Asbestos and Lead-Based Paint XRF Survey Report March 11, 2020

Page 14

Page 31: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

Fullerton Joint Union High School District Bainbridge Environmental Consultants, Inc. La Habra High School – Aquatics Facility Comprehensive Asbestos and Lead-Based Paint XRF Survey Report March 11, 2020

Page 15

APPENDIX D

ASBESTOS AND LEAD-BASED PAINT XRF SAMPLE LOCATION DRAWINGS

Page 32: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

Fullerton Joint Union High School District La Habra High School – Aquatic Facility

Asbestos Bulk Sample Location Drawing (Co-Gen 260 & Acid Room Samples 1-21, 31-36 & 58-60)

1322 Bell Avenue, Suite 1N, Tustin, California 92870 Tel: (714) 247-0024 Fax: (714) 247-0025

21

20

19

36 58 59 35 60

33

32 34 31

4

6

2

10 3

13 14

11 1

15 12

8

7

5

9

16, 17, 18

Page 33: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

Fullerton Joint Union High School District La Habra High School – Aquatic Facility

Asbestos Bulk Sample Location Drawing (Pool Area Samples 22-30)

1322 Bell Avenue, Suite 1N, Tustin, California 92870 Tel: (714) 247-0024 Fax: (714) 247-0025

25

23

28 30

26

29 27

24

22

Page 34: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

Fullerton Joint Union High School District La Habra High School – Aquatic Facility

Asbestos Bulk Sample Location Drawing (Roof Samples 37-57)

1322 Bell Avenue, Suite 1N, Tustin, California 92870 Tel: (714) 247-0024 Fax: (714) 247-0025

47

37 54

53

43

56 50

38

42 46

55

49

45

39

52

57

48

51

44

40 41

Page 35: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

Fullerton Joint Union High School District La Habra High School – Aquatic Facility

Lead-XRF Sample Location Drawing – Co-Gen 260 & Acid Room (For Reference Only)

1322 Bell Avenue, Suite 1N, Tustin, California 92870 Tel: (714) 247-0024 Fax: (714) 247-0025

D

C

B

A

Page 36: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

Fullerton Joint Union High School District La Habra High School – Aquatic Facility

Lead-XRF Sample Location Drawing – Pool Area (For Reference Only)

1322 Bell Avenue, Suite 1N, Tustin, California 92870 Tel: (714) 247-0024 Fax: (714) 247-0025

A

D

C

B

Page 37: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

Fullerton Joint Union High School District La Habra High School – Aquatic Facility

Lead-XRF Sample Location Drawing – Roof (For Reference Only)

1322 Bell Avenue, Suite 1N, Tustin, California 92870 Tel: (714) 247-0024 Fax: (714) 247-0025

A

D

C

B

Page 38: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

Fullerton Joint Union High School District Bainbridge Environmental Consultants, Inc. La Habra High School – Aquatics Facility Comprehensive Asbestos and Lead-Based Paint XRF Survey Report March 11, 2020

Page 16

APPENDIX E

SURVEY PHOTOGRAPHS

Page 39: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

Fullerton Joint Union High School District La Habra High School – Aquatics Facility

Survey Photographs

Page 40: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

Fullerton Joint Union High School District La Habra High School – Aquatics Facility

Survey Photographs

Page 41: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

Fullerton Joint Union High School District La Habra High School – Aquatics Facility

Survey Photographs

Page 42: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

Fullerton Joint Union High School District La Habra High School – Aquatics Facility

Survey Photographs

Page 43: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

Fullerton Joint Union High School District La Habra High School – Aquatics Facility

Survey Photographs

Page 44: COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF …

Fullerton Joint Union High School District La Habra High School – Aquatics Facility

Survey Photographs