Complex Techniques

• Hydrometry

• Whole-Body Counting and Neutron Activation Analysis

• Dual Energy X-Ray Absorptiometry

• Imaging Techniques

Page 2: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Hydrometry

• Water is the most abundant of the constituents of the body.

• It makes up 70-75% of weight at birth, but less than 40% in obese adults.

Page 3: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Hydrometry

Dilution Principle

• States that the volume of the compartment is equal to the amount of tracer added to the compartment divided by the concentration of the tracer in that compartment.

Page 4: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Hydrometry

• With this method, the concentration of either hydrogen or oxygen isotopes in biological fluids (e.g., saliva, plasma, and urine) after equilibration is measured and used to estimate total body water.

Page 5: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Hydrometry

• The tracers used in the in-vivo dilution do not behave in an ideal manner.

• Thus, measurement of TBW in-vivo requires careful attention to these deviations from the basic assumptions underlying the dilution principle.

Page 6: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Hydrometry

Precision of total body water

• The precision of the total body water measurement is dependent on the analytical method as well as the dose of tracer administered to the subject.

Page 7: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Hydrometry

• In general, mass spectrometric methods have been the most precise.– Using two isotopes the precision is 1 - 2%.– Using other analytical methods the precision is

between 2 - 4%.

Page 8: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Hydrometry

• Procedural variations such as the physiological fluid selected for sampling, equilibration time, the estimated correction factor for the isotropic dilution space, and the method selected for assaying the labeled water may all contribute to an increased technical error.

Page 9: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Whole-Body Counting

• Scintillation detectors were developed in the early 1950’s.

• They measure the body’s natural potassium as well as other radioactivity in the body.

Page 10: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Whole-Body Counting

• In 1958, Kulwich, Feinstein, and Anderson correlated natural potassium concentration with fat free mass.

Page 11: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Whole-Body Counting

• There are an estimated 75 counters in the US.

• There are more than 180 whole-body counters worldwide.

• Two-thirds of these perform body potassium measurements in humans.

Page 12: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Whole-Body Counting

• Potassium is naturally distributed in three isotopic states.

• The isotope 40K is radioactive.

Page 13: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Whole-Body Counting

• Gamma rays from 40K are high-energy gammas, many of which exit the body and can be easily detected by external counting

• The smaller the subject, the lower the 40K content and thus the weaker gamma signal.

Page 14: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Whole-Body Counting

• Factors such as age, fitness, or restricted mobility due to surgery or illness do not tend to affect the precision of total body potassium measurements.

• The 40K signal is natural and continuous, therefore the measurement can be interrupted as necessary, until counting is completed.

Page 15: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Whole-Body Counting

The three requirements for 40K whole body-counting include:

• Efficient gamma-ray detectors that can be placed close to the subject.

• Shielding for these detectors to reduce the natural background radiation levels (cosmic rays, radioactive contaminants in construction materials)

Page 16: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Whole-Body Counting

• Computer-based instruments that enable identification of the unique gamma rays.

Page 17: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Whole-Body Counting

Precision:

• For whole-body counters, precision is in the range of 2-5% for adults.

• In infants and very young children, accurate measurements have been difficult to obtain. The precision is only 8-12% for 40 minute sample times.

Page 18: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Whole-Body Counting

• Cost depends on age range of the population being examined.

• Total cost for an adult whole-body counter is $10,000-15,000.

• Cost of a special shielded room starts at $80,000.

• These are just start-up costs.

Page 19: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Neutron Activation Analysis

• IVNAA measures 11 elements from nuclear reactions.

• Protein, mineral, and fat can be estimated from these elements:– Carbon = Lipid– Nitrogen = Protein– Calcium = Bone

Page 20: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Neutron Activation Analysis

• IVNNA use a whole-body counter.

• It delivers a moderate beam of fast neutrons to the subject.

• Atoms of target elements capture these neutrons.

• This creates an unstable isotope.

Page 21: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Neutron Activation Analysis

• Unstable isotopes produce gamma rays when returning to a stable state.

• Gamma rays are measured:– energy level identifies the element– the activity indicates its abundance.

Page 22: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Prompt-Gamma Activation Analysis

• The isotope gets very excited with the added neurons.

• This lasts only a fraction of a nanosecond before it returns to a stable state.

• It is therefore measured simultaneously as the neutrons are exposed to the isotope.

Page 23: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Neutron Activation Analysis

Disadvantages:

• Radiation exposure.

• Must be performed by medical personnel

• Cost $30,000 - $300,000.

Page 24: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Ultrasound

• Uses high frequency sound waves that are produced by a piezoelectric crystal in a transducer.

Page 25: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Ultrasound

• A common source of error is the occurrence of multiple echoes from connective tissue layers within the SAT, particularly over the abdomen.

Page 26: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Ultrasound

• The disadvantages of ultrasound, in comparison with calipers, are its greater expense and lesser portability.

• Careful site location is also crucial.

Page 27: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Ultrasound

• Its advantages over the measurement of skinfold thickness in the obese are now recognized more widely.

Page 28: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Dual Energy X-Ray Absorptiometry (DEXA)

• DEXA was originally developed to estimate bone mineral content.

• DEXA estimation of body fat is based on the attenuation of two energy x-rays through the body.

Page 29: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

DEXA

• From each x-ray, DEXA software provides an estimation of the ratio of fat and lean tissue in each computerized pixel.

Page 30: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.
Page 31: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

DEXA

Femoral Neck Lumbar Spine

Page 32: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

DEXA

• To perform a DEXA reading, subjects lie in a prone position for approximately 12 minutes for an x-ray scan from head to toe.

Page 33: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

DEXA

• This technology is attractive because it can be used to assess regional body composition as well.

• Additionally, this method requires virtually no effort on the part of the participant and does not depend on technician skill.

Page 34: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

DEXA

Applicability:

• DEXA is applicable through low radiation exposure.– Radiation levels are 100 times less than

common x-ray.

Page 35: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

DEXA

Disadvantages:

• Can not be used during pregnancy.

• Special software required for infants.

Page 36: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

DEXA

Advantages:

• All ages are included.

• Low radiation as compared to common x-rays.

• Food or fluid intake have little affect on results.

• DEXA is approved for research in USA.

Page 37: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

DEXAEquipment:• Hologic QDR (1988)

– Uses alternately pulsed x-ray beams.

• Lunar DPX (1990)– Sends rays from beneath person and measures energy

sent through them.

• Norland XR (1993)– Uses dynamic filtration which adjusts to patient

thickness.

Page 38: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

DEXA

Summary

• There is general agreement that some of the new DEXA software programs offer precise measurement of body composition.

• With additional studies, it is very possible that DEXA may become the new “gold” standard of body fat assessment.

Page 39: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

DEXA

Summary

• However, more validation studies are needed to determine the affect of various conditions such as hydration levels and disease state.

Page 40: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Imaging Techniques

• New technologies have allowed researchers to measure body composition in ways that were once impossible:– Computer assisted tomography (CAT scan)– Magnetic resonance imaging (MRI)

Page 41: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Computer Assisted Tomography

• A radiological technique that is commonly used for diagnostic purposes.

• Cross sectional areas of adipose tissue, muscle and bone can be measured with CT scans at any body site.

Page 42: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Computer Assisted Tomography

Basic Principles:

• An x-ray tube and detectors are located at opposite poles of a large ring.

• Tube rotates around the table

• Subject lies with arm stretched above their head.

• Computer generates image from attenuated beams to recognize tissues.

Page 43: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Computer Assisted Tomography

Precision:

• Adipose tissue from CT correlated high (r = 0.98) with chemically extracted lipid mass in rats.

• Difference between measurements of total AT volume is about 0.6%.

Page 44: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Computed Tomography and BC

• CT is an accurate technique for the assessment of body composition, and it does not rely on assumptions such as the constancy of either the density or the water content of fat free mass.

Page 45: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Computed Tomography and BC

• The most important application of CT in the field of body composition has been to the measurement of abdominal VAT.

Page 46: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Magnetic Resonance Imaging

• Based on the interaction between nuclei (proton) of hydrogen atoms and the magnetic fields generated and controlled by the instrumentation of the MRI system.

Page 47: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

MRI

• The MRI field strength is 10,000 times stronger than that of earth.

• Protons tend to align with the magnetic field.

• A pulsed radio frequency (RF) field is applied to body tissues causing protons to absorb energy.

Page 48: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

MRI

• RF field is turned off, protons return to original position and release energy absorbed.

Page 49: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

MRI

• MRI data acquisition is programmed to take advantage of specific proton density and relaxation times (rate at which absorbed energy is released) to contrast between AT and skeletal muscle.

Page 50: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

MRI

Limitations:

• Time required to obtain quality images approximately 8 minutes for the abdominal region.

• Motion caused by respiration and cardiac function decrease image quality.

Page 51: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

MRI

Accuracy

• Only one report compared MRI measurements of AT with those derived by dissection of human cadavers.

• Found mean of 6% difference in VAT of 3 cadavers.

Page 52: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

MRI and BC

• Because multiple images can be obtained without any known health risks to the subject, MRI is well suited for assessment of whole body AT distribution.

Page 53: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

MRI and BC

• There have been several groups using a multi-slice protocol to evaluate whole body AT distribution.

Page 54: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

MRI and BC

• MRI is useful for discrimination between VAT and SAT accumulation.

Page 55: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

MRI and Whole-Body Lean Tissue

• Whole body lean tissue from MRI in obese men and women can be predicted with an accuracy of 3.6% and 6.5% respectively.

Page 56: Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Summary

• Need for further validation of CT and MRI.

• Tools of choice for precise measurements of SAT and VAT

• VAT assessment is critical in assessment of health risks.