Commissioning Sral Xd-pdh

42
Li dC i i i P d Line-up and Commissioning Procedure SRALXD-PDH Bandung, Sept 2008, TI Department Bandung, Sept 2008, TI Department 1 © Nokia Siemens Networks Presentation / Author / Date For internal use

Transcript of Commissioning Sral Xd-pdh

Page 1: Commissioning Sral Xd-pdh

Li d C i i i P dLine-up and Commissioning Procedure SRALXD-PDH

Bandung, Sept 2008, TI DepartmentBandung, Sept 2008, TI Department

1 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Page 2: Commissioning Sral Xd-pdh

Microwave Band Frequency

RF Bands (GHz) 4 5 6 7 8 10 5 13 15 18 23 26 28 32 41 583811

Trunk Radio (SRT Family)• NxSTM 1 (AP/CC)

RF Bands (GHz) 4 5 6 7 8 10.5 13 15 18 23 26 28 32 41 583811

Backbone SRT 1FNxSTM 1 (AP/CC)

Access and Mobile Radio (SRA & SRAL families)• STM 1 (HD/ND) (SRA Family)

Backbone- SRT 1F

SRA 4-Family

• NxE1 (SRA XD Family)

TMN

SRA L / SRAL XD

N tVi NME S it

SRAL XD-Family

• NMSNetViewer NME Suite

2 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 3: Commissioning Sral Xd-pdh

Tools and Test Instruments

LAPTOP / PC : WINDOWS 2000, XP Internet Explorer 6 MS Office xlsInternet Explorer 6, MS Office xls.LCT Engine Engine 6.0 or higher+PLUG IN----for SRALXD match with SVR-XDLCT CABLE (db9 to db 9 – pin to pin).RJ45 –Lan Cable “cross type””Analog Multimeter (suggested) or Digital

MultimeterPDH i l A l E1 T t 64KbPDH signal Analyzer –E1 Tester, 64Kbps Tester,

3 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 4: Commissioning Sral Xd-pdh

SRAL XDFamily OverviewFamily Overview

ODU HD/HPODU ND

• 16 TCM High Density• 4 CPM Normal Density• 4 QAM High Performance

IDU SingleBoard

• No Frequency Diversity

IDU Plug-in• Full set of configurations

(1+1 HSBY 1+1 FD etc)q y yNo 2x(1+0) / AD repeater

(1+1 HSBY, 1+1 FD, etc)

4 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 5: Commissioning Sral Xd-pdh

IDU Type

.

5 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 6: Commissioning Sral Xd-pdh

.

6 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 7: Commissioning Sral Xd-pdh

Installation

7 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 8: Commissioning Sral Xd-pdh

External Connection

8 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 9: Commissioning Sral Xd-pdh

External E1 Tributary 120 Ohm type

9 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 10: Commissioning Sral Xd-pdh

Alarm Input –Output : Should be connected to ENVA alarm in Repeater site & Grounding must be Installed before XD Switch ON.

10 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 11: Commissioning Sral Xd-pdh

Check Coax-Feeder Cable& Insertion of Memory Key

.

11 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 12: Commissioning Sral Xd-pdh

WARNING Installation Problem!! Water Infiltration

.

12 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 13: Commissioning Sral Xd-pdh

Q LAN, V LAN : connection (See DCN PLAN!!)

.

13 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 14: Commissioning Sral Xd-pdh

How to created Dial Up for SRAL XD

.

14 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 15: Commissioning Sral Xd-pdh

ACTIVATION SRALXD

Step Activation :1. Log In (Use LCT 6.0 with Plug in SRALXD )g ( g )2. By LCT LOCAL CHECK > Physical check.3. Alignment Software.( If any Software not yet align)4. Configure SRAL base on LB –Link Budget data, • System-Freq-Tx Power, Capacity ,etc (both site)5. Adjust Antenna (Pointing). Reach RX level Calculation (+/-4dB).6. Test Loop back (Local Loop & Remote Loop ) for All E1.6. Test Loop back (Local Loop & Remote Loop ) for All E1.7. Hop Test -Switching Test. (for 1+1 type)

15 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 16: Commissioning Sral Xd-pdh

Log in

O MAPOpen MAP:1. LocalAuto or LNeTnmpE

16 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 17: Commissioning Sral Xd-pdh

Log in Password

LOG In, User Admin UserUser: Admin UserPassword: sysmanager

17 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 18: Commissioning Sral Xd-pdh

Physical alarm Check !

.

18 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 19: Commissioning Sral Xd-pdh

Aligned Software- Alarm!

5nd DownLoad

4nd DownLoad

3nd DownLoad

First DownLoad

2Nd DownLoad

Check The Menu Software Bank.(Red-Alarm):has to be Down Load.1. Down Load “One by ONE!!” (NOT in paralel time).2. Never Un-plug LCT Cable during Down Load.3. Never Switch OFF IDU during Down Load.4 Make sure Baterey Laptop & DC IDU enough Power (min 30 Minute)!!

19 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

4. Make sure Baterey Laptop & DC IDU enough Power (min 30 Minute)!!5. Down Load software start form (Bottom to Up see arrow direction)

Page 20: Commissioning Sral Xd-pdh

Alligment Software -Done

ALL GREEN….Normal Condition.

20 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

NB: FPGA =Field Programmable Gate Array

Page 21: Commissioning Sral Xd-pdh

SET – SYSTEM Type (1+0 or 1+1 HSBY or 1+1 etc)

Double Click :Ch h S Pl Li k B dChange the System as Plan-Link Budget

21 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 22: Commissioning Sral Xd-pdh

Ex: After Change the System

Ex : 1+1 HSBYEx : 1+1 HSBY

22 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 23: Commissioning Sral Xd-pdh

Change the Capacity-as Plan(NDB)

Change the Capacity:

23 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 24: Commissioning Sral Xd-pdh

Set The Frequency …..& TX Power…See LB(link budget)g )

Double Click to Set The Frequency,

Double Click to Set The Frequency,

Insert Frequency Value (KHz)

24 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 25: Commissioning Sral Xd-pdh

SET the TX Activation ON…

SET Activation ON : Mean ODU startTransmit RF Power

25 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 26: Commissioning Sral Xd-pdh

SET Switching Type (only for 1+1 setting).

Reference Set Switching Type :

Revertive: 1+1 HSBY Mounting Un -Balance)

Unrevertive :Using“Mounting Balance”

26 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 27: Commissioning Sral Xd-pdh

Set IP Adress- Call Implementation Manager or Regional Äcces Planner if IP not available!g

Mandatory IP Address MUST BE SET: DO NOT Leave as default!!y- Test Ping from NE to GNE

27 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 28: Commissioning Sral Xd-pdh

After Set Tx, Freq, Cap, (both Site) Alignments/Pointing ! – Kiri Kanan Atas Bawah!g g

Multimeter

28 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 29: Commissioning Sral Xd-pdh

Cross Connection

.

29 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 30: Commissioning Sral Xd-pdh

RX & TX Switch Menu

. FOR TX Switch : Not Hitless

FOR RX Switch=Hitless

1 = BB2, 2=BB2

Local=Same as TXODUonlineEX: Status Data : TX on ODU 1

30 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions. EX: Status Data : RX on ODU 1

Page 31: Commissioning Sral Xd-pdh

R- interface must be set IP – for remote Log in

.

Set NE parameter , (Set R interface to IP)I t t!! FOR GNE Sit S DCN S t RiP Sil t

31 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Important!!: FOR GNE Site See DCN – Set RiP Silent Enable- For Other site “Set as Default”

Page 32: Commissioning Sral Xd-pdh

LED Summary

.

32 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 33: Commissioning Sral Xd-pdh

Interference Check

.

33 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 34: Commissioning Sral Xd-pdh

Performance

.

34 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 35: Commissioning Sral Xd-pdh

1. Inventory – attached at ATP Document

,

35 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 36: Commissioning Sral Xd-pdh

UPGRADE LICENSE

.

Availability of SRALXD can be Configured

Insert License number to Upgrade License

36 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 37: Commissioning Sral Xd-pdh

Example : DCN Plan

37 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 38: Commissioning Sral Xd-pdh

SEE GNE -5 (Connected by UC-User Channel)

38 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 39: Commissioning Sral Xd-pdh

See IP: 10.63.232.79at site 101069 ! ….GNE-5 not in BSC Site!!

39 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 40: Commissioning Sral Xd-pdh

Example – GNE (Gateway Network Element)

40 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 41: Commissioning Sral Xd-pdh

Reset –Hop Setting

41 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Nokia Siemens Networks is expected to start operations in Q1 2007, subject to regulatory approvals and the closing conditions.

Page 42: Commissioning Sral Xd-pdh

CONFIDENTIAL- Silahkan share ke tam yang membutuhkan ☺

Hatur Nuhun Thank You!42 © Nokia Siemens Networks Presentation / Author / DateFor internal use

Hatur Nuhun -Thank You!