COMMERCIAL TEST REPORT (INITIAL Validity: 31.12 - srfmtti.dacnet.nic…srfmtti.dacnet.nic.in/test...

4
Page 1 of 32 वयावसाययक परीकण यरपोरट (पार यिक) सखया@No: Machine-263/952 COMMERCIAL TEST REPORT माह@Month: January, 2019 (INITIAL) Validity: 31.12.2023 STANISH POWER SP - 1050 D POWER WEEDER िरत सरकार Government of India कृयष एव यकसान कलयाण मतालय Ministry of Agriculture and Farmers Welfare कृयष, सहकायरता एव यकसान कलयाण यविाग Department of Agriculture, Cooperation and Farmers Welfare दयकणी केत कृयष मशीनरी पयशकण एव परीकण ससथान Southern Region Farm Machinery Training and Testing Institute टैकरर नगर, गालटयदने -515 731, यिला: अनतपुर (. .) Tractor Nagar, Garladinne-515 731, District: Anantapur (A.P.) [An ISO 9001:2015 CERTIFIED INSTITUTE] Website: http://srfmtti.dacnet.nic.in/ E-mail: [email protected] Tele./FAX: 08551-286441

Transcript of COMMERCIAL TEST REPORT (INITIAL Validity: 31.12 - srfmtti.dacnet.nic…srfmtti.dacnet.nic.in/test...

Page 1: COMMERCIAL TEST REPORT (INITIAL Validity: 31.12 - srfmtti.dacnet.nic…srfmtti.dacnet.nic.in/test reports upload 2018-19/952-Stanish Power... · STANISH POWER SP – 1050 D POWER

Page 1 of 32

व्यावसाययक परीक्षण यरपोर्ट (प्रारंयिक) संख्या@No: Machine-263/952

COMMERCIAL TEST REPORT माह@Month: January, 2019

(INITIAL) Validity: 31.12.2023

STANISH POWER SP - 1050 D POWER WEEDER

िारत सरकार Government of India

कृयष एवं यकसान कल्याण मंत्रालय

Ministry of Agriculture and Farmers Welfare

कृयष, सहकायरता एवं यकसान कल्याण यविाग Department of Agriculture, Cooperation and Farmers Welfare

दयक्षणी के्षत्र कृयष मशीनरी प्रयशक्षण एवं परीक्षण संस्थान Southern Region Farm Machinery Training and Testing Institute

ट्रैक्र्र नगर, गालटयदने्न-515 731, यिला: अनंतपुर (आं. प्र.) Tractor Nagar, Garladinne-515 731, District: Anantapur (A.P.)

[An ISO 9001:2015 CERTIFIED INSTITUTE]

Website: http://srfmtti.dacnet.nic.in/

E-mail: [email protected] Tele./FAX: 08551-286441

Page 2: COMMERCIAL TEST REPORT (INITIAL Validity: 31.12 - srfmtti.dacnet.nic…srfmtti.dacnet.nic.in/test reports upload 2018-19/952-Stanish Power... · STANISH POWER SP – 1050 D POWER

Machine-

263/952

STANISH POWER SP – 1050 D

POWER WEEDER

COMMERCIAL

(ICT)

SOUTHERN REGION FARM MACHINERY TRAINING & TESTING INSTITUTE,

ANANTAPUR, (A.P.) Page 2 of 32

SANISH POWER SP - 1050 E POWER WEEDER

Report No. : Machine-263/952 Month: January Year: 2019

Government of India

Ministry of Agriculture and Farmers Welfare

Department of Agriculture, Cooperation and Farmers Welfare

Southern Region Farm Machinery Training and Testing Institute

Tractor Nagar, Garladinne-515 731, District: Anantapur (A.P.)

[An ISO 9001:2015 CERTIFIED INSTITUTE]

Telephone: 08551-286441 Fax: 08551-286441

Website: http://srfmtti.dacnet.nic.in/ E-mail: [email protected]

Manufacturer

:

M/s. Chongqing Meiqi Industry Co. Ltd.,

Chongqing Kzoor Electromechanical Co.

Ltd., China.

Applicant : M/s. Stanish Power,

Wadjai Mata Nagar, Towards Makhmalabad

Gaon Road, Next to Makhmalabad Cannel,

Panchavati, Nashik - 422 003, Maharashtra.

Page 3: COMMERCIAL TEST REPORT (INITIAL Validity: 31.12 - srfmtti.dacnet.nic…srfmtti.dacnet.nic.in/test reports upload 2018-19/952-Stanish Power... · STANISH POWER SP – 1050 D POWER

Machine-

263/952

STANISH POWER SP – 1050 D

POWER WEEDER

COMMERCIAL

(ICT)

SOUTHERN REGION FARM MACHINERY TRAINING & TESTING INSTITUTE,

ANANTAPUR, (A.P.) Page 30 of 32

17. COMMENTS & RECOMMENDATIONS

17.1 Engine Performance:

17.1.1 The maximum & rated powers were observed as 4.5 kW under natural

ambient condition against the declared value of 4.2 kW.

17.1.2 Back up torque of engine was observed as 6.60 % against the declared

value of 10 %. Therefore, this should be looked into for corrective action.

17.1.3 Specific fuel consumption of engine corresponding to maximum power

and at rated engine speed was recorded as 194 g/kWh against the declared

value of 290 g/kWh. This should be looked into for corrective action.

17.1.4 Maximum torque was observed as 15.17 Nm against the declared value of

19 Nm.

17.2 Maximum Noise at operator’s ear level was observed as 92 dB (A), which

is higher as per ILO. Therefore corrective action to reduce the noise

should also be taken.

17.3 The amplitude of mechanical vibration on most of the assemblies of the

Power Weeder was observed as higher side and to the extent of maximum

606 microns, Which is directly concerned with Operator’s Health, Safety and Comfort. Besides, it also adversely affects the useful life of the

components. In view of the above, this should be taken care for corrective

action.

17.4 The hardness of rotor blades does not conform to the requirement of IS

6690:1981 (Reaffirmed 2012).

17.5 All constituents except carbon of chemical composition of rotor blade are

conforming the requirement of IS 6690:1981 (Reaffirmed 2012). This

should be looked into for corrective action.

17.6 The applicant has declared the rated engine speed as 3000 rpm and

accordingly tested at its declared speed only. Whereas in the labeling plate

riveted on the machine, the rated rpm is mentioned as 3600 rpm. This

should be looked into for corrective action.

Page 4: COMMERCIAL TEST REPORT (INITIAL Validity: 31.12 - srfmtti.dacnet.nic…srfmtti.dacnet.nic.in/test reports upload 2018-19/952-Stanish Power... · STANISH POWER SP – 1050 D POWER