्यावसाययक परीषण यरपो्ट सं्या No.: IMP-458/871...

4
Page 1 of 25 वयावसाययक परीकण यरपोरट खया@ No.: IMP-458/871 COMMERCIAL TEST REPORT माह:@ Month: June, 2018 SOUTHERN AGRO BRIGHT STAR 5 FEET ROTAVATOR (Tractor Mounted, PTO Operated) भारत सरकार Government of India कृयष एव यकसान कलयाण मतालय Ministry of Agriculture and Farmers Welfare कृयष, सहकायरता एव यकसान कलयाण यवभाग Department of Agriculture, Cooperation and Farmers Welfare दयकणी केत कृयष मशीनरी पयशकण एव परीकण ससथान Southern Region Farm Machinery Training and Testing Institute टैकरर नगर, गालटयदने - 515 731, यिला: अनतपुर (. .) Tractor Nagar, Garladinne- 515 731, District: Anantapur (A.P.) [An ISO 9001:2015 CERTIFIED INSTITUTE] Website: http://srfmtti.dacnet.nic.in/ E-mail: [email protected] Tele./FAX: 08551-286441

Transcript of ्यावसाययक परीषण यरपो्ट सं्या No.: IMP-458/871...

Page 1: ्यावसाययक परीषण यरपो्ट सं्या No.: IMP-458/871 …srfmtti.dacnet.nic.in/test reports upload 2018-19... · ROTAVATOR (Tractor Mounted,

Page 1 of 25

व्यावसाययक परीक्षण यरपोर्ट सखं्या@ No.: IMP-458/871

COMMERCIAL TEST REPORT माह:@ Month: June, 2018

SOUTHERN AGRO BRIGHT STAR 5 FEET ROTAVATOR

(Tractor Mounted, PTO Operated)

भारत सरकार Government of India

कृयष एवं यकसान कल्याण मंत्रालय

Ministry of Agriculture and Farmers Welfare

कृयष, सहकायरता एवं यकसान कल्याण यवभाग Department of Agriculture, Cooperation and Farmers Welfare

दयक्षणी के्षत्र कृयष मशीनरी प्रयशक्षण एवं परीक्षण संस्थान Southern Region Farm Machinery Training and Testing Institute

ट्रैक्र्र नगर, गालटयदने्न - 515 731, यिला: अनंतपुर (आं. प्र.) Tractor Nagar, Garladinne- 515 731, District: Anantapur (A.P.)

[An ISO 9001:2015 CERTIFIED INSTITUTE]

Website: http://srfmtti.dacnet.nic.in/

E-mail: [email protected] Tele./FAX: 08551-286441

Page 2: ्यावसाययक परीषण यरपो्ट सं्या No.: IMP-458/871 …srfmtti.dacnet.nic.in/test reports upload 2018-19... · ROTAVATOR (Tractor Mounted,

IMP-

458/871

SOUTHERN AGRO BRIGHT STAR 5 FEET

ROTAVATOR (Tractor Mounted, PTO Operated)

Commercial

SOUTHERN REGION FARM MACHINERY TRAINING & TESTING INSTITUTE -

ANANTAPUR [An ISO 9001:2015 CERTIFIED INSTITUTE]

Page 2 of 25

Southern Agro Bright Star 5 Feet Rotavator

Report No. : IMP-458/871 Month: June Year: 2018

Government of India

Ministry of Agriculture and Farmers Welfare

Department of Agriculture, Cooperation and Farmers Welfare

Southern Region Farm Machinery Training and Testing Institute

Tractor Nagar, Garladinne- 515 731, District: Anantapur (A.P.) [An ISO 9001:2015 CERTIFIED INSTITUTE]

Telephone: 08551-286441 Fax: 08551-286441

Website: http://srfmtti.dacnet.nic.in/ E-mail: [email protected]

Manufacturer

:

M/s. Southern Agro Engine Private Limited,

# 24A, III phase, Industrial Estate, Guindy,

Chennai-600 032, Tamilnadu, India.

Applicant : The Manufacturer

Page 3: ्यावसाययक परीषण यरपो्ट सं्या No.: IMP-458/871 …srfmtti.dacnet.nic.in/test reports upload 2018-19... · ROTAVATOR (Tractor Mounted,

IMP-

458/871

SOUTHERN AGRO BRIGHT STAR 5 FEET

ROTAVATOR (Tractor Mounted, PTO Operated)

Commercial

SOUTHERN REGION FARM MACHINERY TRAINING & TESTING INSTITUTE -

ANANTAPUR [An ISO 9001:2015 CERTIFIED INSTITUTE]

Page 22 of 25

9. EASE OF OPERATION & ADJUSTMENTS

No difficulty was observed during the operation and adjustment of rotavator.

10. DEFECTS, BREAKDOWNS AND REPAIRS

No defect/breakdown and repair was occurred during entire period of field

& lab tests.

11. SUMMARY OF OBSERVATIONS, COMMENTS AND

RECOMMENDATION

11.1 No ingress of dust and water/mud in primary reduction gear box,

secondary reduction gear box, and rotary axle bearing cap was

observed.

11.2 Provisions for breather cap is provided in primary and secondary gearbox.

11.3 Parking stand & safety device are provided in rotavator.

11.4 Provision for oil level in primary gearbox needs to be provided.

11.5 The specification of implement hitch is not conforming in full to the IS 4468

(Pt-I):1997.

11.6 Dimensions of PIC yoke is conforming where as PIC is not conforming to IS

4931:1995. This should be looked into for corrective action.

11.7 The hardness of rotor blades at edge and shank portion do not meet, the

requirement of IS 6690:1981. This should be looked into for corrective

action.

11.8 Carbon & manganese content of rotor blades do not meet the requirement of

IS 6690:1981. This should be looked into.

11.9 Parameters of labeling plate need to be declared as per IS requirement.