CIRCUIT Protection 32 CIRCUIT PROTECTION Ctec Residual Current Circuit Breaker Ctec Ordering Scheme Ctec Poles 2, 4 2 Rated Current 2 pole : 25, 40, 63, 80, 100A 4 pole : 25, 40, 63A Residual Current Sensitivity 010 = 10mA 030 = 30mA 100 = 100mA 300 = 300mA 500 = 500mA 030 63 Ctec RCCB Technical Specificaon The Ctec range provides stylish and cost effective residual current (earth leak) fault protection in both 2 and 4 poles. Note the Ctec RCCB device does not provide overload or short circuit protection and should be used in conjunction with a miniature circuit breaker (Gtec or Jtec). EN 61008-1 EN 61008-2-1 Up to 100A Number of poles 2 or 4 Rated Voltage (Un) 110, 230, 400 V Frequency 50 / 60Hz Max. Operating Voltage Vn + 10% Residual Current Sensitivity 10, 30, 100, 300, 500 mA Current Rating 2 pole: 25, 40, 63, 80, 100A 4 pole: 25, 40, 63A Ambient Temperature -5°C to +40°C Electrical Life 6000 Switching Operations

Transcript of CIRCUIT EN 61008-1 EN 61008-2-1 CIRCUIT · CIRCUIT. Protection 32. CIRCUIT. PROTECTION. Ctec....

Page 1: CIRCUIT EN 61008-1 EN 61008-2-1 CIRCUIT · CIRCUIT. Protection 32. CIRCUIT. PROTECTION. Ctec. Residual Current Circuit Breaker. Ctec Ordering Scheme. Ctec. Poles. 2, 4. 2. Rated Current.

CIRC

UIT

Pro

tect

ion

32

CIRCUIT PROTECTION

Ctec Residual Current Circuit Breaker

Ctec Ordering Scheme

Ctec

Poles2, 4

2

RatedCurrent

2 pole : 25, 40, 63, 80, 100A 4 pole : 25, 40, 63A

Residual CurrentSensitivity

010 = 10mA030 = 30mA

100 = 100mA300 = 300mA500 = 500mA

03063

Ctec RCCB Technical Specification

The Ctec range provides stylish and cost effective residual current (earth leak) fault protection in both 2 and 4 poles.

Note the Ctec RCCB device does not provide overload or short circuit protection and should be used in conjunction with a miniature circuit breaker (Gtec or Jtec).

EN 61008-1EN 61008-2-1

Up to 100A

Number of poles 2 or 4

Rated Voltage (Un) 110, 230, 400 V

Frequency 50 / 60Hz

Max. Operating Voltage Vn + 10%

Residual Current Sensitivity 10, 30, 100, 300, 500 mA

Current Rating 2 pole: 25, 40, 63, 80, 100A 4 pole: 25, 40, 63A

Ambient Temperature -5°C to +40°C

Electrical Life 6000 Switching Operations

Page 2: CIRCUIT EN 61008-1 EN 61008-2-1 CIRCUIT · CIRCUIT. Protection 32. CIRCUIT. PROTECTION. Ctec. Residual Current Circuit Breaker. Ctec Ordering Scheme. Ctec. Poles. 2, 4. 2. Rated Current.

CTEC RCCBs

33

CIRCUIT PROTECTION

Ctec Residual Current Circuit Breaker

Ctec Ordering Scheme

Ctec

Poles2, 4

2

RatedCurrent

2 pole : 125A4 pole : 100, 125A

Residual CurrentSensitivity

010 = 10mA030 = 30mA

100 = 100mA300 = 300mA500 = 500mA

030100

Ctec RCCB Technical Specification

The Ctec High current versions provide residual current protection for circuits with loads upto 125A.

Note the Ctec RCCB device does not provide overload or short circuit protection and should be used in conjunction with a miniature circuit breaker (Gtec or Jtec).

100A - 125A

Number of poles 2 or 4

Rated Voltage (Un) 110, 230, 400 V

Frequency 50 / 60Hz

Max. Operating Voltage Vn + 10%

Residual Current Sensitivity 10, 30, 100, 300, 500 mA

Current Rating 2 pole: 125A 4 pole: 100, 125A

Ambient Temperature -5°C to +40°C

Electrical Life 6000 Switching Operations