Construction Plan Review
Construction plans will require approval by the local regulatory authority.
Benefits of a regulatory review: Ensures design meets regulatory
requirements Ensures safe flow of food May save time and money Ensures contractors are constructing the
facility correctly Ensures approved equipment is being used
11-2
Facility Design
A well-designed kitchen will address: Workflow
o It must keep food out of the temperature danger zone as much as possible
o It must limit the number of times foodis handled
11-3
Facility Design
A well-designed kitchen will address: Contamination
o The risk of cross-contamination must be minimizedo Place equipment to prevent splashing or spillage from one piece of equipment
to another Equipment accessibility
o Place equipment so staff can easily clean the facility and all equipment
11-4
Material Selection for Interior Construction
Flooring must be: Smooth Durable Nonabsorbent Easy to clean
For use in these areas: Walk-in coolers Prep and food-storage Dishwashing Restrooms Dressing and locker rooms
11-5
Material Selection for Interior Surfaces
Coving: Curved, sealed edge placed
between the floor and wall Eliminates sharp corners or gaps that are
hard to clean Must be glued tightly to the
wall to o Eliminate hiding places for pestso Protect the wall from moisture
11-6
Interior Walls and Ceilings
Materials must be: Smooth Nonabsorbent Durable Easy to clean
11-7
Handwashing Stations
Handwashing stations must be conveniently located and are required in: Restrooms or directly next to them Food-prep areas Service areas Dishwashing areas
Handwashing sinks must be used only for handwashing.
11-8
Handwashing Stations
Handwashing stations must have:
Hot and cold running water
Soap A way to dry hands
Garbage container Signage
11-9
Equipment Standards
Look for the NFS mark when purchasing equipment: Ensures food equipment surfaces are
o Nonabsorbento Smootho Corrosion resistanto Easy to cleano Durableo Resistant to damage
11-10
Dishwashing Machines
Dishwashers must be installed: So they are reachable and conveniently
located In a way that keeps utensils, equipment,
and other food-contact services from becoming contaminated
Following manufacturer’s instructions
11-11
Dishwashing Machines
When selecting dishwashers make sure: The detergents and sanitizers used are
approved by the local regulatory authority They have the ability to measure water
temperature, water pressure, and cleaning and sanitizing chemical concentration
Information about the correct settings is posted on the machine
11-12
Three-Compartment Sinks
Purchase sinks large enough to accommodate large equipment and utensils.
11-13
Floor-mounted equipment must be either: Mounted on legs at least six inches
(15 centimeters) high Sealed to a masonry base
11-14
Installing and Maintaining Equipment
Tabletop equipment should be either: Mounted on legs at least four inches
(10 centimeters) high Sealed to the countertop
11-15
Installing and Maintaining Equipment
Installing and Maintaining Equipment
Once equipment has been installed: It must be maintained regularly Only qualified people should maintain it Set up a maintenance schedule with your
supplier or manufacturer Check equipment regularly to make sure
it is working correctly
11-16
Water Supply
Acceptable sources of drinkable water: Approved public water mains Regularly tested and maintained private sources Closed, portable water containers Water transport vehicles
11-17
11-18
Plumbing
Cross-connection: Physical link between safe water and dirty water from
o Drains o Sewers o Other wastewater sources
Plumbing
Backflow: Reverse flow of contaminants through
a cross-connection into the drinkable water supply
Backsiphonage: A vacuum created in the plumbing system
that sucks contaminants back into the water supply o Can occur when high water use in one area
of the operation creates a vacuum o A running hose in a mop bucket can lead
to backsiphonage
11-19
Vacuum breaker
Backflow prevention methods:
Air gap
11-20
Plumbing
Sewage
If there is a backup of sewage in the operation: The affected area should be closed right away The problem must be corrected The area must be thoroughly cleaned
If the backup is a significant risk to food safety: Service must be stopped The local regulatory authority must be notified
11-21
Lighting
Consider the following when installing and maintaining lighting: Different areas of the facility have different
lighting intensity requirements Local jurisdictions usually require prep areas to
be brighter than other areas All lights should have shatter-resistant lightbulbs
or protective covers Replace burned out bulbs with correct size bulbs
11-22
Ventilation systems: Must be cleaned and maintained to prevent
grease and condensation from building up on walls and ceilingso Follow manufacturer’s recommendationso Meet local regulatory requirements
11-23
Ventilation
Garbage
Garbage: Remove from prep areas as quickly
as possible o Be careful not to contaminate food and
food-contact surfaces Clean the inside and outside of containers
frequentlyo Clean them away from food-prep and
storage areas
11-24
Garbage
Indoor containers must be: Leak proof, waterproof, and pest proof Easy to clean Covered when not in use
Designated storage areas: Store waste and recyclables separately
from food and food-contact surfaces Storage must not create a nuisance or a
public health hazard
11-25
Garbage
Outdoor containers must: Be placed on a smooth, durable,
nonabsorbent surfaceo Asphalt or concrete
Have tight-fitting lids Be covered at all times Have their drain plugs in place
11-26