CH 2800 CH 3000 - Hauraki District · ch 329 ch 400 ch 600 ch 800 ch 1000 ch 1200 ch 1400 ch 1600...
Transcript of CH 2800 CH 3000 - Hauraki District · ch 329 ch 400 ch 600 ch 800 ch 1000 ch 1200 ch 1400 ch 1600...
270
280
290
300
310
320
320320
330
330
330
340350
360360
360
370
380
390
400
410
420
420
420
420
420
430
440
450
460
470
480
260 270
280
290
300 310
320 330 340
350
360
370
38039
0
400
410
420430
440450
460
200
200
210
210
210
210
210
210220
220
230
230
240
240
250
250
260
260260
260
270
270270
270
280
280
290
290
230
240
250 260
260
260
260260
270
280 280280
29029029030030
0
300
310
320
330330330340
340
340
340340
350
350
350350350350
350
360360
360
370
380
390
400410
420430
430430
440
440
440
450460
300 310
430 430
440
440 440450450
450
460460
460470480480
250
TURBINE 20EASTING:484412.40NORTHING:736013.03
TURBINE 18EASTING:484027.58
NORTHING:736439.35
TURBINE 19EASTING:484423.16NORTHING:736382.64
CH 0
CH 200
CH 40
0
CH 60
0CH
624
CH 0
CH 200
CH 400
CH 600
CH
200
CH 329
CH 400
CH 600
CH 800
CH 1000
CH 1200
CH 1400
CH 1600
CH 1800
CH 2000
CH 2200 C
H 2400
CH 2600
C
C
EXISTING SLOPE TRIANGLE GREATER THAN 25°
PROPOSED ROAD 7
PROPOSED ROAD 8
PROPOSED ROAD 9
PROPOSED ROAD 10
PROPOSED ROAD 7
TEKTUS Consultants LtdPO Box 80212 Green Bay
Auckland 0643 NZp. 09 827 1191
m. 021 1434 874www.tektus.nz
VENTUS ENERGY (NZ) LTD10/215 ROSEDALE ROAD, ALBANYAUCKLAND 0632
SYNERGY POSITIONING SYSTEMS LTD3/52 ARRENWAY DRIVE, ALBANY,AUCKLAND 0632
KAIMAI WIND FARMROTOKOHU ROAD, PAEROA
PRELIMINARY CIVIL ENGINEERINGDRAWINGS
A RESOURCE CONSENT JT 15.06.18
1. FOR INFORMATION PURPOSES ONLY.2. BOUNDARIES, CONTOURS AND OTHER BASE INFORMATIONSHOWN IS INDICATIVE ONLY AND PRIMARILY INFORMED BYAERIAL LIDAR SURVEY BY SYNERGY POSITIONING SYSTEMS LTDIN APRIL 2016.3. COORDINATES SHOWN ARE IN TERMS OF MT EDEN 2000CIRCUIT AND LEVELS ARE RELATIVE TO THE AUCKLAND 1946VERTICAL DATUM.4. THE PROPOSED ROAD ALIGNMENT, TURBINE PLATFORMS,AND OVERALL EARTHWORKS ARE BASED ON AN INDICATIVEROAD ALIGNMENT AND REMAIN SUBJECT TO DETAILED DESIGN.5.VOLUME ESTIMATES BASED ON COMPARISON OF EXISTING &PROPOSED SURFACE LEVELS & DO NOT ACCOUNT FORSUBGRADE CUT, BULKING OR COMPACTION FACTORS.OVERALL AREA & VOLUME ESTIMATES INCLUDE 20%CONTINGENCY FOR ADDITIONAL EARTHWORKS IF NECESSARYTHROUGH DETAILED DESIGN.
15.06.18 JT JT
T15022 A
LEGENDEXISTING PARCEL BOUNDARY
JACKSON PROPERTY BOUNDARY
ROTOKOHU FARMS PROPERTY BOUNDARY
DENIZE BROTHERS PROPERTY BOUNDARY
HDC/MPDC TERRITORIAL BOUNDARY
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
PROPOSED MAJOR CONTOUR
PROPOSED MINOR CONTOUR
EXTENT OF EARTHWORK
PROPOSED TURBINE LOCATION
EXISTING TRANSPOWER NATIONALGRID LINES
PROPOSED ROAD CENTER LINE ANDEDGE OF CARRIAGEWAY
EXISTING FENCE
INDICATIVE QUARRY SITE
INDICATIVE CLEANFILL SITE
EXISTING CULVERT
PROPOSED UPGRADED CULVERT
STREAM (WRC REGIONAL MAP)
PP
RESOURCE CONSENT
C
Q
250-5
1:5000
EROSION AND SEDIMENT CONTROLOVERVIEW DETAIL PLAN SHEET 5
16.10.18
ADDITIONAL PLAN FOR S92 RESPONSE LT 16.10.18
LT
25°
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
42042
0420
420
430
440
450
460
470
480
330 340
350
360
370
38039
0
400
410
420430
440450
460
320
330
330
330
340
350
360
370
380
390
400
410
420
430
440
440
440
450
460
470 48
0
420420
430
430
430
430
430
430
440
440
440
440
450
450
46047048
0
490
490500
500
420
430
430
43044
0
440
440
450
450
450
450
45046
0
460
470
470470
470
480
480
480480
440
450
460
470
TURBINE 20EASTING:484412.40NORTHING:736013.03
TURBINE 24EASTING:485345.86
NORTHING:735060.70
TURBINE 22EASTING:485205.70
NORTHING:735845.84
TURBINE 23EASTING:485388.88
NORTHING:735566.94
TURBINE 21EASTING:484943.93NORTHING:736153.72
CH 0
CH 44
CH 0
CH
200
CH 329
CH 2600
CH 2800
CH 3000
CH 3200
CH 3400
CH 3600
CH 3800
CH 4000
CH 4200
CH 4400
CH
4600
CH
4636
ASSEMBLY AREA 3 (100x30)EASTING:485093.05NORTHING:736109.06
CH 0CH 20
CH 40CH 60
CH 80CH 100
CH 120CH 140
CC
C
C
C
C
EXISTING SLOPE TRIANGLE GREATER THAN 25°PROPOSED ROAD 7
PROPOSED ROAD 7
PROPOSED ROAD 7
PROPOSED ROAD 10
INDICATIVE SUBSTATIONPLATFORM
EXISTING TRANSPOWERNATIONAL GRID LINES
TEKTUS Consultants LtdPO Box 80212 Green Bay
Auckland 0643 NZp. 09 827 1191
m. 021 1434 874www.tektus.nz
VENTUS ENERGY (NZ) LTD10/215 ROSEDALE ROAD, ALBANYAUCKLAND 0632
SYNERGY POSITIONING SYSTEMS LTD3/52 ARRENWAY DRIVE, ALBANY,AUCKLAND 0632
KAIMAI WIND FARMROTOKOHU ROAD, PAEROA
PRELIMINARY CIVIL ENGINEERINGDRAWINGS
A RESOURCE CONSENT JT 15.06.18
1. FOR INFORMATION PURPOSES ONLY.2. BOUNDARIES, CONTOURS AND OTHER BASE INFORMATIONSHOWN IS INDICATIVE ONLY AND PRIMARILY INFORMED BYAERIAL LIDAR SURVEY BY SYNERGY POSITIONING SYSTEMS LTDIN APRIL 2016.3. COORDINATES SHOWN ARE IN TERMS OF MT EDEN 2000CIRCUIT AND LEVELS ARE RELATIVE TO THE AUCKLAND 1946VERTICAL DATUM.4. THE PROPOSED ROAD ALIGNMENT, TURBINE PLATFORMS,AND OVERALL EARTHWORKS ARE BASED ON AN INDICATIVEROAD ALIGNMENT AND REMAIN SUBJECT TO DETAILED DESIGN.5.VOLUME ESTIMATES BASED ON COMPARISON OF EXISTING &PROPOSED SURFACE LEVELS & DO NOT ACCOUNT FORSUBGRADE CUT, BULKING OR COMPACTION FACTORS.OVERALL AREA & VOLUME ESTIMATES INCLUDE 20%CONTINGENCY FOR ADDITIONAL EARTHWORKS IF NECESSARYTHROUGH DETAILED DESIGN.
15.06.18 JT JT
T15022 A
LEGENDEXISTING PARCEL BOUNDARY
JACKSON PROPERTY BOUNDARY
ROTOKOHU FARMS PROPERTY BOUNDARY
DENIZE BROTHERS PROPERTY BOUNDARY
HDC/MPDC TERRITORIAL BOUNDARY
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
PROPOSED MAJOR CONTOUR
PROPOSED MINOR CONTOUR
EXTENT OF EARTHWORK
PROPOSED TURBINE LOCATION
EXISTING TRANSPOWER NATIONALGRID LINES
PROPOSED ROAD CENTER LINE ANDEDGE OF CARRIAGEWAY
EXISTING FENCE
INDICATIVE QUARRY SITE
INDICATIVE CLEANFILL SITE
EXISTING CULVERT
PROPOSED UPGRADED CULVERT
STREAM (WRC REGIONAL MAP)
PP
RESOURCE CONSENT
C
Q
250-6
1:5000
PROPOSED ROAD 12
TRANSMISSION TOWERS TOBE LOCATED IN THIS AREA -FINAL LOCATION SUBJECT TODETAILED DESIGN
INDICATIVE TURNING AREA
INDICATIVE LOCATION FORPROPOSED 110kV LATTICETRANSMISSION TOWER
EROSION AND SEDIMENT CONTROLOVERVIEW DETAIL PLAN SHEET 6
16.10.18
ADDITIONAL PLAN FOR S92 RESPONSE LT 16.10.18
LT
25°
160
220220
270
280
260
250
260
270
280
290160
170
180
190
200
210
220
230
240
250
260
270
280
190
200
210
220
230
240
250
260
280
290
300
310
200
200
200200
210
210
210210
210 210
220
220
220220
230
230
230
230
240
240
240
240
250
250
260
260
270
270270
270
280
280
290
290
300
300
310310
TURBINE 16EASTING:482608.80NORTHING:735269.84
ASSEMBLY AREA 2 (100x30)EASTING:483115.48NORTHING:735382.29
TURBINE 17EASTING:483065.27NORTHING:735308.18
CH 400
CH 600
CH 800
CH 1000
CH 1200
CH 1400
CH 1600
CH 1800
CH 0
CH 200CH 251
EXISTING SLOPE TRIANGLE GREATER THAN 25°
PROPOSED ROAD 8
PROPOSED ROAD 8
PROPOSED ROAD 11
TEKTUS Consultants LtdPO Box 80212 Green Bay
Auckland 0643 NZp. 09 827 1191
m. 021 1434 874www.tektus.nz
VENTUS ENERGY (NZ) LTD10/215 ROSEDALE ROAD, ALBANYAUCKLAND 0632
SYNERGY POSITIONING SYSTEMS LTD3/52 ARRENWAY DRIVE, ALBANY,AUCKLAND 0632
KAIMAI WIND FARMROTOKOHU ROAD, PAEROA
PRELIMINARY CIVIL ENGINEERINGDRAWINGS
A RESOURCE CONSENT JT 15.06.18
1. FOR INFORMATION PURPOSES ONLY.2. BOUNDARIES, CONTOURS AND OTHER BASE INFORMATIONSHOWN IS INDICATIVE ONLY AND PRIMARILY INFORMED BYAERIAL LIDAR SURVEY BY SYNERGY POSITIONING SYSTEMS LTDIN APRIL 2016.3. COORDINATES SHOWN ARE IN TERMS OF MT EDEN 2000CIRCUIT AND LEVELS ARE RELATIVE TO THE AUCKLAND 1946VERTICAL DATUM.4. THE PROPOSED ROAD ALIGNMENT, TURBINE PLATFORMS,AND OVERALL EARTHWORKS ARE BASED ON AN INDICATIVEROAD ALIGNMENT AND REMAIN SUBJECT TO DETAILED DESIGN.5.VOLUME ESTIMATES BASED ON COMPARISON OF EXISTING &PROPOSED SURFACE LEVELS & DO NOT ACCOUNT FORSUBGRADE CUT, BULKING OR COMPACTION FACTORS.OVERALL AREA & VOLUME ESTIMATES INCLUDE 20%CONTINGENCY FOR ADDITIONAL EARTHWORKS IF NECESSARYTHROUGH DETAILED DESIGN.
15.06.18 JT JT
T15022 A
LEGENDEXISTING PARCEL BOUNDARY
JACKSON PROPERTY BOUNDARY
ROTOKOHU FARMS PROPERTY BOUNDARY
DENIZE BROTHERS PROPERTY BOUNDARY
HDC/MPDC TERRITORIAL BOUNDARY
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
PROPOSED MAJOR CONTOUR
PROPOSED MINOR CONTOUR
EXTENT OF EARTHWORK
PROPOSED TURBINE LOCATION
EXISTING TRANSPOWER NATIONALGRID LINES
PROPOSED ROAD CENTER LINE ANDEDGE OF CARRIAGEWAY
EXISTING FENCE
INDICATIVE QUARRY SITE
INDICATIVE CLEANFILL SITE
EXISTING CULVERT
PROPOSED UPGRADED CULVERT
STREAM (WRC REGIONAL MAP)
PP
RESOURCE CONSENT
C
Q
250-7
1:5000
PROPOSED ROAD 11
EROSION AND SEDIMENT CONTROLOVERVIEW DETAIL PLAN SHEET 7
16.10.18
ADDITIONAL PLAN FOR S92 RESPONSE LT 16.10.18
LT
25°
WAITOKI STREAM
320
320
320
330
330
330
340
350
360
360
360
370
380
390
400
410
340
340
340340
350
350
350350350350
350
360
360
360
370
380
390
400410
420430
430 430
440
440
440
450
TURBINE 18EASTING:484027.58
NORTHING:736439.35
CH 1200
CH 1400
CH 1600
CH 1800
CH 2000
FS
FS
FS
FS
FS
FS
FS
SSF
460458462464466
LEGEND - SUPPLEMENTARYINDICATIVE CLEAN WATER/STREAM FLOWSINDICATIVE DIRTY WATER FLOWSPROPOSED SUPER SILT FENCEPROPOSED FILTER SOCKSPROPOSED DIRTY WATER DIVERSIONPROPOSED DECANTING EARTH BUNDPROPOSED SEDIMENT PITPROPOSED SEDIMENT DETENTION PONDPROPOSED GRASS BUFFER ZONEPROPOSED TURKEY NESTPROPOSED NON ERODIBLE BARRIER DAMINDICATIVE PUMPED FLOWINDICATIVE FLOW FROM PUMPINGEXISTING SLOPE TRIANGLE GREATER THAN 25°
SSF
FS
DWD
<
DEB
T
PROPOSED ROAD 7
TEKTUS Consultants LtdPO Box 80212 Green Bay
Auckland 0643 NZp. 09 827 1191
m. 021 1434 874www.tektus.nz
VENTUS ENERGY (NZ) LTD10/215 ROSEDALE ROAD, ALBANYAUCKLAND 0632
SYNERGY POSITIONING SYSTEMS LTD3/52 ARRENWAY DRIVE, ALBANY,AUCKLAND 0632
KAIMAI WIND FARMROTOKOHU ROAD, PAEROA
PRELIMINARY CIVIL ENGINEERINGDRAWINGS
A RESOURCE CONSENT JT 15.06.18
1. FOR INFORMATION PURPOSES ONLY.2. BOUNDARIES, CONTOURS AND OTHER BASE INFORMATIONSHOWN IS INDICATIVE ONLY AND PRIMARILY INFORMED BYAERIAL LIDAR SURVEY BY SYNERGY POSITIONING SYSTEMS LTDIN APRIL 2016.3. COORDINATES SHOWN ARE IN TERMS OF MT EDEN 2000CIRCUIT AND LEVELS ARE RELATIVE TO THE AUCKLAND 1946VERTICAL DATUM.4. THE PROPOSED ROAD ALIGNMENT, TURBINE PLATFORMS,AND OVERALL EARTHWORKS ARE BASED ON AN INDICATIVEROAD ALIGNMENT AND REMAIN SUBJECT TO DETAILED DESIGN.5.VOLUME ESTIMATES BASED ON COMPARISON OF EXISTING &PROPOSED SURFACE LEVELS & DO NOT ACCOUNT FORSUBGRADE CUT, BULKING OR COMPACTION FACTORS.OVERALL AREA & VOLUME ESTIMATES INCLUDE 20%CONTINGENCY FOR ADDITIONAL EARTHWORKS IF NECESSARYTHROUGH DETAILED DESIGN.
15.06.18 JT JT
T15022 A
LEGENDEXISTING PARCEL BOUNDARY
JACKSON PROPERTY BOUNDARY
ROTOKOHU FARMS PROPERTY BOUNDARY
DENIZE BROTHERS PROPERTY BOUNDARY
HDC/MPDC TERRITORIAL BOUNDARY
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
PROPOSED MAJOR CONTOUR
PROPOSED MINOR CONTOUR
EXTENT OF EARTHWORK
PROPOSED TURBINE LOCATION
EXISTING TRANSPOWER NATIONALGRID LINES
PROPOSED ROAD CENTER LINE ANDEDGE OF CARRIAGEWAY
EXISTING FENCE
INDICATIVE QUARRY SITE
INDICATIVE CLEANFILL SITE
EXISTING CULVERT
PROPOSED UPGRADED CULVERT
STREAM (WRC REGIONAL MAP)
PP
RESOURCE CONSENT
C
Q
251-1
1:2000
EROSION AND SEDIMENT CONTROLDETAIL SHEET 1 - ACCESS TRACKESTABLISHMENT - INDICATIVE ONLY
05.10.18
ADDITIONAL PLAN FOR S92 RESPONSE LT 05.10.18
LT
ANY CULVERTS IN HEADWATERSTREAMS REQUIRE DAM ANDPUMPING OF FLOWS.FILTER SOCKS DIVERT RUNOFF FROMTRACK AWAY FROM STREAM SYSTEMS
POTENTIAL TEMPORARYSTOCKPILE LOCATION
NOTES
1. STRIP TOPSOIL AND PLACE IN LOCATIONS WITH “INDEPENDENT” EROSION AND SEDIMENTCONTROL CAN BE ESTABLISHED
2. CUT AND COVER TO BE IMPLEMENTED WHERE AS CUT AND FILL OCCURS ALONG TRACKSURFACE IT IS STABILISED PROGRESSIVELY
3. CUT AND FILL BATTERS TO BE STABILISED WITH NATURAL ROCK MATERIAL OR MULCH ANDVEGETATED
4. BELOW FILL BATTERS FILTER SOCKS TO BE STRATEGICALLY PLACED AS NECESSARY
5. EARTHWORKS TO ADVANCE NO MORE THAN 24 HOURS IN FRONT OF THE STABILISED ROADSURFACE
6. SEDIMENT PITS TO BE ESTABLISHED TO COLLECT ROAD SURFACE RUNOFF AND DISCHARGEINTO GRASS ENVIRONMENT WHERE CONTOURS ALLOW
7. ALL CULVERTS TO BE INSTALLED IN DRY PERIOD AND ANY FLOWS TEMPORARILY DAMMEDAND PUMPED TO BELOW ACCESS TRACK WORKS
8. STOCK EXCLUSION TO OCCUR DURING EARTHWORKS ACTIVITY
9. ALL PRINCIPLES AS PER ESCP SECTION 5.0 TO APPLY
10.DETAILED SSESCP TO BE ESTABLISHED PRIOR TO ANY EARTHWORKS OCCURRING
11.WRC EROSION AND SEDIMENT CONTROL GUIDELINES TO APPLY
12.MONITORING TO OCCUR AS PER ESCP SECTION 11 WITH AN ADAPTIVE CONTINUOUSIMPROVEMENT APPROACH