Micro Motion® Certified Bunker Measurement Solution Vessel Operator Guide for Marine Bunkering
Barge Captain of Bunker Tanker
Chief Engineerof Vessel
BEF
OR
E B
UN
KER
ING
DU
RIN
G B
UN
KER
ING
AFT
ER B
UN
KER
ING
3. Both Barge Captain and Chief Engineer must check the flowmeter display to confirm the totalizer value is “0” and no alarms are displayed.
4. If totalizer is not “0” then print a ticket
1. Check that the pressure in the bunker line is “0” and bunker line is empty
Series 3000 Transmitter
In addition: Monitor the drive gain trend on the BunkerLink profile. If the drive gain is increasing and exceeds 75%, take action to reduce aeration
It is normal for drive gain to exceed 75% at the beginning and end of the bunker delivery, as lines are being filled or cleared
In order to meet certification measurement requirements ensure the aeration limit reads below 100%, at the end of bunker. It is important to monitor the metering diagnostics. Watch for “aeration present” and trends in drive gain.
1. If aeration is present, take action to reduce the aeration. For example, add backpressure
Aeration Present: If it displays “YES”, there is air in the line right now. This diagnostic is on the BunkerLink profile screen and transmitter display
2. Check that all permanent seals are in and all sight glasses are clean
5. Take steps to minimize amount of air through the flowmeter before the delivery begins
6. Connect BunkerLink 20 minutes before transfer begins
7. Open the bunker Manifold
MC-001708 ©2013 Emerson Process Management. All rights reserved.
For more information, please contact your local Micro Motion Marine Sales Representative.
Manifold
4. Check to see the BDN value is within company acceptable limits
1. If the pressure doesn’t read “0”, vent the bunker line
2. Check that all sight glasses are clean, verify pressure reading is “0” and that seals are intact
3. A passing ticket is a valid custody transfer measurement
PASS!*Approved Measurement*
50.4979
243%
YES
50.4979
243%
YES
*Approved Measurement*Micro Motion, Inc, Emerson Process Management
Mass in Vacuum 1725.27 t
OIML 0.5% Class: Pass
OIML R117-1 accuracy: PassMID Certificate #: T 1234
IMPORTANT: Attach this ticket to BDN Report
Displayed when the ticket passes
Measurement criteria pass/fail displayed here
Transferred mass displayed here
5. If required by your company, return to the corporate office the following documents: Copy of BDN, Bunker Ticket and Bunker profile report, Data file
Supplier Information:
Receiving Vessel Information:
Delivery Information:
Supplier’s Representative Date Signed
Receiving Vessel Representative Date Signed
BDN
Bunker Profile Mass Flow Rate
File Connection Help
Monitor Diagnostic Info History
Mass Flow Rate
Mass Total
Mass Inventory
Drive Gain
mTon/hr
mTon
mTon
%
550.1325
50.49
35,659.93
100
Density
Temperature Drive Gain
600
0
1040
960
40
20
9 10
Tem
p (°C
)M
ass
Flow
Rat
e
Density (Kg/m3)
100
Time
0
Drive Gain (%
)
Liquid Detector
Elasped Time: 00:04:23Alerts Events
Wet
Actual Density
API Density
Temperature
% Max Aeration Limit
kg/m3
kg/m3
°C
%
973.69
976.16
38.6
243
Aeration Present Yes
BunkerLink