Catalog PSS
-
Upload
franco-kalcich -
Category
Documents
-
view
252 -
download
2
description
Transcript of Catalog PSS
2
1. ELECTRONIC TRANSFORMERS
HR SMPS 3003 4
HR SMPS 4206 5
2. AC-DC Power Supply General Purpose
Single Output 7 - 16
Dual Output 17 - 18
Triple Output 19 - 21
Quad Output 22 - 23
3. Din-Rail Power Supply
HDA Series 25 - 30
HDR Series 31
4. LED Driver
LED Driver Constant Current 33 - 38
LED Driver Constant Voltage 40 - 43
5. Open Frame Power Supply
Single Output Open Frame 45 - 48
3
4
Input AC Voltage Range 90-264Vac
Line Frequency 50 – 60Hz
Input Power no load ≤ 0.3W max. at 230Vac
Max Power out 3W at 230Vac
Output Ripple < 200mVpp
Efficiency Typ. ≥ 70%
Rise Time Output Voltage 3 sec max. at 80%
Output over current protection No damage shall occur. Self recovering when condition is removed
Output short circuit protection No damage shall occur. Self recovering when condition is removed
Hi-pot test 4500Vdc; 3sec; 5mA
DC- insulation resistance 10MΩ minimum at 500Vdc
* TEMPERATURE CHARACTERISTICS
1.- Storage ambient temperature: -30°C ~ +70°C
2.- Operating ambient temperature: 0°C ~ +60°C
3.- Storage Humidity: 10% ~ 95%
4.- Operating Humidity: 10% ~ 90%
* MAXIMUM WORKING TEMPERATURE
Ambient Temperature: ta 60ºC
Thermal Class : B (130°C)
SAFETY: According to EN 60950
EN 60335
EN 61558-2-17
EMC According to EN 55022
EN 55014
EN 61000-4-X
RoHS According to Directive 2002/95/CE.
Reference Output Voltage Output Current
3,3 V 0,9 A 3003103
5 V 0,6 A 3003105
9 V 0,33 A 3003109
12 V 0,25 A 3003112
15 V 0,2 A 3003115
18 V 0,16 A 3003118
24 V 0,12 A 3003124
5
Input AC Voltage Range 90-264Vac
Line Frequency 50 – 60Hz
Input Power no load ≤ 0.3W max. at 230Vac
Max Power out 6W at 230Vac
Output Ripple < 200mVpp
Efficiency Typ. ≥ 70%
Rise Time Output Voltage 3 sec max. at 80%
Output over current protection No damage shall occur. Self recovering when condition is removed
Output short circuit protection No damage shall occur. Self recovering when condition is removed
Hi-pot test 4500Vdc; 3sec; 5mA
DC- insulation resistance 10MΩ minimum at 500Vdc
* TEMPERATURE CHARACTERISTICS
1.- Storage ambient temperature: -30°C ~ +70°C
2.- Operating ambient temperature: 0°C ~ +60°C
3.- Storage Humidity: 10% ~ 95%
4.- Operating Humidity: 10% ~ 90%
* MAXIMUM WORKING TEMPERATURE
Ambient Temperature: ta 60ºC
Thermal Class : B (130°C)
SAFETY: According to EN 60950
EN 60335
EN 61558-2-17
EMC According to EN 55022
EN 55014
EN 61000-4-X
RoHS According to Directive 2002/95/CE.
Reference Output Voltage Output Current
4206105 5 V 1,2 A
4206109 9 V 0,66 A
4206112 12 V 0,5 A
4206115 15 V 0,4 A
4206118 18 V 0,33 A
4206124 24 V 0,25 A
6
7
Input Voltage Range 85-364VAC; 120-370VDC
Input Frequency 47-63Hz
Inrush Current Cold Start, 15A/115VAC, 25A/230VAC
Output Adjustment Range ±10% Rated Output Voltage
Line Regulation ≤5%
Output Over Load Protection 110%~150% Hiccup Mode, Auto-recovery
Output Over Voltage Protection 115%~135% Rated-Output Voltage
Output Short Circuit Protection Hiccup Mode, Auto-recovery
Rise, Hold Up Time 50mS, 20mS at Full Load (typical)
Hi-pot Isolation I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG:0.5KVAC
Operating Temperature Range 0ºC to +50ºC @ 100%, -10ºC@80%,+60ºC@60% Load
Storage Temperature Range -40ºC to +85ºC, 0 to 95%RH (Non-Condensing)
Safety Standards UL60950-1 TUV EN60950-1
EN55022 class B, EN61000-3-2,3 EMC standards
EN61000-4-2,3,4,5,6,8,11,ENV50204
Cooling Method Free Air Cooling Convenction
Weight 0.39 Kg/pcs
Universal Input 85 to 264 VAC
EMI Meets EN55022(CISPR22) Class B
Low Power Consumption
Approvals: UL/CUL/TUV/CB/CE
Protections: Over Load/Over Voltage/Short Circuit
100% Full Load High Temperature Burn-in Test
2 Years Warranty
Product model DC Output Load Regulation R&N Efficiency
HR S-25F-5 5V, 0~5A 1% 50mV 73%
HR S-25F-12 12V, 0~2.1A 0.5% 100mV 77%
HR S-25F-15 15V, 0~1.7A 0.5% 100mV 78%
HR S-25F-24 24V, 0~1.1A 0.5% 100mV 81%
8
Input Voltage Range 85~264VAC; 120~370VDC
Input Frequency 47-63Hz
Inrush Current Cold Start, 15A/115VAC, 25A/230VAC
Output Adjustment Range ±10% Rated Output Voltage
Line Regulation ≤0.5%
Output Over Load Protection 105%~150% Hiccup Mode, Auto-recovery
Output Over Voltage Protection 115%~135% Rated-Output Voltage
Output Short Circuit Protection Hiccup Mode, Auto-recovery
Rise, Hold Up Time 50mS, 20mS at Full Load (typical)
Hi-pot Isolation I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG:0.5KVAC
Operating Temperature Range 0ºC to +50ºC @ 100%, -10ºC@80%,+60ºC@60% Load
Storage Temperature Range -40ºC to +85ºC, 0 to 95%RH (Non-Condensing)
Safety Standards UL60950-1 TUV EN60950-1
EN55022 class B, EN61000-3-2,3 EMC standards
EN61000-4-2,3,4,5,6,8,11,ENV50204
Cooling Method Free Air Cooling Convenction
Weight 0.44 Kg/pcs
Universal Input 85 to 264 VAC
EMI Meets EN55022(CISPR22) Class B
Low Power Consumption
Approvals: UL/CUL/TUV/CB/CE
Protections: Over Load/Over Voltage/Short Circuit
100% Full Load High Temperature Burn-in Test
2 Years Warranty
Product model DC Output Load Regulation R&N Efficiency
HR S-40F-5 5V, 0~8A 1% 75mV 74%
HR S-40F-12 12V, 0~3.5A 0.5% 100mV 78%
HR S-40F-15 15V, 0~2.8A 0.5% 100mV 79%
HR S-40F-24 24V, 0~1.8A 0.5% 100mV 81%
9
Input Voltage Range 85~264VAC; 120~370VDC
Input Frequency 47-63Hz
Inrush Current Cold Start, 25A/115VAC, 50/230VAC
Output Adjustment Range ±10% Rated Output Voltage
Line Regulation ≤0.5%
Output Over Load Protection 105%~150% Hiccup Mode, Auto-recovery
Output Over Voltage Protection 115%~135% Rated-Output Voltage
Output Short Circuit Protection Hiccup Mode, Auto-recovery
Rise, Hold Up Time 50mS, 20mS at Full Load (typical)
Hi-pot Isolation I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC
Operating Temperature Range 0ºC to +45ºC @ 100%, -10ºC@80%,+60ºC@60% Load
Storage Temperature Range -40ºC to +85ºC, 0 to 95%RH (Non-Condensing)
Safety Standards UL60950-1 TUV EN60950-1
EN55022 class B, EN61000-3-2,3 EMC standards
EN61000-4-2,3,4,5,6,8,11,ENV50204
Cooling Method Free Air Cooling Convenction
Weight 0.51 Kg/pcs
Universal Input 85 to 264 VAC
EMI Meets EN55022(CISPR22) Class B
Low Power Consumption
Approvals: UL/CUL TUV/CB/CE
Protections: Over Load/Over Voltage/Short Circuit
100% Full Load High Temperature Burn-in Test
2 Years Warranty
Product model DC Output Load Regulation R&N Efficiency
HR S-60F-5 5V, 0~12A 1% 100mV
73%
HR S-60F-12 12V, 0~5A 1% 120mV 77%
HR S-60F-15 15V, 0~4A 0.5% 150mV
78%
HR S-60F-24 24V, 0~2.5A 0.5% 150mV 81%
10
Input Voltage Range 88~132VAC; 176~264VAC Selectable By Switch
Input Frequency 47-63Hz
Inrush Current Cold Start, 25A/115VAC, 50A/230VAC
Output Adjustment Range ±10% Rated Output Voltage
Line Regulation ≤0.5%
Output Over Load Protection 105%~150% Hiccup Mode, Auto-recovery
Output Over Voltage Protection 115%~135% Rated-Output Voltage
Output Short Circuit Protection Hiccup Mode, Auto-recovery
Rise, Hold Up Time 50mS, 20mS at Full Load (typical)
Hi-pot Isolation I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC
Operating Temperature Range 0ºC to +50ºC @ 100%, -10ºC@80%,+60ºC@60% Load
Storage Temperature Range -40ºC to +85ºC, 0 to 95%RH (Non-Condensing)
Safety Standards UL60950-1 TUV EN60950-1
EN55022 class B, EN61000-3-2,3 EMC standards
EN61000-4-2,3,4,5,6,8,11,ENV50204
Cooling Method Free Air Cooling Convenction
Weight 0.65 Kg/pcs
AC Input Range Selectable By Switch
EMI Meets EN55022(CISPR22) Class B
Low Power Consumption
Approvals: UL/CUL/ TUV/CB/CE
Protections: Over Load/Over Voltage/Short Circuit
100% Full Load High Temperature Burn-in Test
2 Years Warranty
Product model DC Output Load Regulation R&N Efficiency
HR S-100F-5 5V, 0~20A 1% 75mV 77%
HR S-100F-7.5 7.5V, 0~13.5 1% 100mV 79%
HR S-100F-12 12V, 0~8.3A 0.5% 120mV 81%
HR S-100F-15 15V, 0~6.8A 0.5% 120mV 82%
HR S-100F-24 24V, 0~4.2A 0.5% 150mV 84%
HR S-100F-48 48V, 0~2.2A 0.5% 150mV 85%
11
Input Voltage Range 88~132VAC/ 176~264VAC Selectable By Switch
Input Frequency 47-63Hz
Inrush Current Cold Start, 30A/115VAC, 50A/230VAC
Output Adjustment Range ±10% Rated Output Voltage
Line Regulation ≤0.5%
Output Over Load Protection 105%~150% Shut Off, AC Recycle To Re-Start
Output Over Voltage Protection 115%~145% Rated-Output Voltage
Output Short Circuit Protection Shut Off, AC Recycle To Re-Start
Rise, Hold Up Time 50mS, 20mS at Full Load (typical)
Hi-pot Isolation I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG:0.5KVAC
Operating Temperature Range 0ºC to +50ºC @ 100%, -10ºC@80%,+60ºC@60% Load
Storage Temperature Range -40ºC to +85ºC, 0 to 95%RH (Non-Condensing)
Safety Standards UL60950-1 TUV EN60950-1
EN55022 class B, EN61000-3-2,3 EMC standards
EN61000-4-2,3,4,5,6,8,11,ENV50204
Cooling Method Free Air Cooling Convenction
Weight 0.8 Kg/pcs
AC Input Range Selectable By Switch
EMI Meets EN55022(CISPR22) Class B
Low Power Consumption
Approvals: UL/CUL/ TUV/CB/CE
Protections: Over Load/Over Voltage/Short Circuit
100% Full Load High Temperature Burn-in Test
2 Years Warranty
Product model DC Output Load Regulation R&N Efficiency
HR S-150F-3.3 3.3V,0~30A 1.5% 100mV 72%
HR S-150F-5 5V,0~30A 1% 100mV 78%
HR S-150F-7.5 7.5V,0~20A 1% 100mV 80%
HR S-150F-9 9V,0~16.5A 1% 100mV 80%
HR S-150F-12 12V,0~12.5A 0.5% 120mV 82%
HR S-150F-13.5 13.5V,0~11A 0.5% 120mV 83%
HR S-150F-15 15V,0~10A 0.5% 150mV 84%
HR S-150F-24 24V,0~6.5A 0.5% 150mV 85%
HR S-150F-27 27V,0~5.6A 0.5% 200mV 86%
HR S-150F-48 48V,0~3.1A 0.5% 200mV 87%
12
Input Voltage Range 88~132VAC/ 176~264VAC Selectable By Switch
Input Frequency 47-63Hz
Inrush Current Cold Start, 25A/115VAC, 50A/230VAC
Output Adjustment Range ±10% Rated Output Voltage
Line Regulation ≤0.5%
Output Over Load Protection 105%~150% Hiccup Mode, Auto-recovery
Output Over Voltage Protection 115%~145% Rated-Output Voltage
Output Short Circuit Protection Hiccup Mode, Auto-recovery
Rise, Hold Up Time 50mS, 20mS at Full Load (typical)
Hi-pot Isolation I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG:0.5KVAC
Operating Temperature Range -10⁰C to +40⁰C @ 100%, -20⁰C@80%,+60⁰C@60% Load
Storage Temperature Range -40⁰C to +85⁰C, 0 to 95%RH (Non-Condensing)
Safety Standards UL60950-1
EN55022 class B, EN61000-3-2,3 EMC standards
EN61000-4-2,3,4,5,6,8,11,ENV50204
Cooling Method Free Air Cooling Convenction
Weight 0.95 Kg/pcs
AC Input Range Selectable By Switch
EMI Meets EN55022(CISPR22) Class B
Low Power Consumption
Approvals: UL/CUL/CE
Protections: Over Load/Over Voltage/Over Temp./Short
Circuit
100% Full Load High Temperature Burn-in Test
2 Years Warranty
Product model DC Output Load Regulation R&N Efficiency
HR S-210F-5 5V, 0~40V 1% 75mV 79%
HR S-210F-7.5 7.5V, 0~27V 1% 100mV 82%
HR S-210F-12 12V, 0~17V 0.5% 120mV 83%
HR S-210F-13.5 13.5V, 0~15V 0.5% 120mV 84%
HR S-210F-15 15V, 0~14V 0.5% 120mV 85%
HR S-210F-24 24V, 0~8.8V 0.5% 150mV 87%
HR S-210F-27 27V, 0~7.8V 0.5% 150mV 87%
HR S-210F-36 36V, 0~5.8V 0.5% 200mV 88%
HR S-210F-48 48V, 0~4.4V 0.5% 200mV 88%
13
Input Voltage Range 88~132VAC/ 176~264VAC Selectable By Switch
Input Frequency 47-63Hz
Inrush Current Cold Start, 15A/115VAC, 30A/230VAC
Output Adjustment Range ±10% Rated Output Voltage
Line Regulation ≤0.5%
Output Over Load Protection 105%~135% Hiccup Mode, Auto-recovery
Output Over Voltage Protection 115%~145% Rated-Output Voltage
Output Short Circuit Protection Hiccup Mode, Auto-recovery
Rise, Hold Up Time 50mS, 20mS at Full Load (typical)
Hi-pot Isolation I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG:0.5KVAC
Operating Temperature Range 0ºC to +40ºC @ 100%, -10ºC@80%,+60ºC@60% Load
Storage Temperature Range -40ºC to +85ºC, 0 to 95%RH (Non-Condensing)
Safety Standards UL60950-1
EMC standards EN55022 class B, EN61000-3-2,3
EN61000-4-2,3,4,5,6,8,11,ENV50204
Cooling Method Forced Air Cooling By Built-in DC Fan, Cooling Fan ON/OFF
Weight 1.08 Kg/pcs
AC Input Range Selectable By Switch
EMI Meets EN55022(CISPR22) Class B
Low Power Consumption
Approvals: UL/CUL/CE
Protections: Over Load/Over Voltage/Over Temp./Short Circuit
100% Full Load High Temperature Burn-in Test
2 Years Warranty
Product model DC Output Load Regulation R&N Efficiency
HR S-320F-5 5V, 0~50A 1% 100mV 78%
HR S-320F-7.5 7.5V, 0~36A 1% 100mV 81%
HR S-320F-12 12V, 0~25A 0.5% 120mV 83%
HR S-320F-13.5 13.5V, 0~22A 0.5% 120mV 84%
HR S-320F-15 15V, 0~20A 0.5% 150mV 85%
HR S-320F-24 24V, 0~12.5A 0.5% 150mV 87%
HR S-320F-27 27V, 0~11A 0.5% 150mV 87%
HR S-320F-36 36V, 0~8.3A 0.5% 200mV 88%
HR S-320F-48 48V, 0~6.5A 0.5% 200mV 88%
14
Input Voltage Range 88~264VAC; 120~370VDC
Input Frequency 47-63Hz
Inrush Current Cold Start, 25A/115VAC, 50A/230VAC
Output Adjustment Range ±10% Rated Output Voltage
Line Regulation ≤0.5%
Output Over Load Protection 105%~135% Hiccup Mode, Auto-recovery
Output Over Voltage Protection 115%~145% Rated-Output Voltage
Output Short Circuit Protection Hiccup Mode, Auto-recovery
Rise, Hold Up Time 50mS, 20mS at Full Load (typical)
Hi-pot Isolation I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG:0.5KVAC
Operating Temperature Range -10ºC to +50ºC @ 100%, -20ºC@80%,+65ºC@50% Load
Storage Temperature Range -40ºC to +85ºC, 0 to 95%RH (Non-Condensing)
Safety Standards UL60950-1
EMC standards EN55022 class B, EN61000-3-2,3
EN61000-4-2,3,4,5,6,8,11,ENV50204
Cooling Method Forced Air Cooling By Built-in DC Fan, Cooling Fan ON/OFF Auto Control
Weight 1.1 Kg/pcs
Universal AC Input 88 to 264VAC
PF>0.98@115VAC;PF>0.95@230VAC
EMI Meets EN55022(CISPR22) Class B
Low Power Consumption
Approvals: UL/CUL/ TUV/CB/CE
Protections: Over Load/Over Voltage/Over Temp./Short Circuit
100% Full Load High Temperature Burn-in Test
2 Years Warranty
Product model DC Output Load Regulation R&N Efficiency
HR SP-320F-3.3 3.3, 0~55A 1.5% 100mV 74%
HR SP-320F-5 5, 0~55A 1% 100mV 79%
HR SP-320F-7.5 7.5, 0~40A 1% 100mV 83%
HR SP-320F-12 12, 0~25A 0.5% 120mV 86%
HR SP-320F-13.5 13.5, 0~22A 0.5% 120mV 86%
HR SP-320F-15 15, 0~20A 0.5% 120mV 86%
HR SP-320F-24 24, 0~13A 0.5% 150mV 87%
HR SP-320F-27 27, 0~11.7A 0.5% 150mV 88%
HR SP-320F-48 48, 0~6.7A 0.5% 200mV 89%
15
Input Voltage Range 180~260VAC
Input Frequency 47-63Hz
Inrush Current Cold Start, 15A/115VAC, 30A/230VAC
Output Adjustment Range ±3% Rated Output Voltage By Potential Meter; 20% to 100% By External Control 1V to 5VDC
Line Regulation ≤0.5%
Output Over Load Protection 105%~135% Hiccup Mode, Auto-recovery
Output Over Voltage Protection 115%~145% Rated-Output Voltage
Output Short Circuit Protection Hiccup Mode, Auto-recovery
Rise, Hold Up Time 50mS, 20mS at Full Load (typical)
Hi-pot Isolation I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG:0.5KVAC
Operating Temperature Range 0ºC to +40ºC @ 100%, -10ºC@80%,+60ºC@60% Load
Storage Temperature Range -40ºC to +85ºC, 0 to 95%RH (Non-Condensing)
Safety Standards UL60950-1
EMC standards EN55022 class B, EN61000-3-2,3
EN61000-4-2,3,4,5,6,8,11,ENV50204
Cooling Method Forced Air Cooling By Built-in DC Fan, Cooling Fan ON/OFF Auto Control
Weight 1.08 Kg/pcs
PF>0.98@230VAC
EMI Meets EN55022(CISPR22) Class B
Low Power Consumption
Approvals: UL/CUL/ TUV/CB/CE
Forced air Cooling By Built-in DC fan
Built-in Remote Sense Function
Built-in Remote ON/OFF Control
Built-in Power Good Signal Output
Can adjust From 20% to 100% Output Voltage By External Control 1V to 5VDC
Protections: Over Load/Over Voltage/Over Temp./ Short Circuit
100% Full Load High Temperature Burn-in Test
2 years Warranty
Product model DC Output Load Regulation R&N Efficiency
HR SP-600F-5 5V, 0~100A 1% 100mV 80%
HR SP-600F-12 12V, 0~50A 0.5% 120mV 84%
HR SP-600F-15 15V, 0~40A 0.5% 150mV 85%
HR SP-600F-24 24V, 0~25A 0.5% 200mV 89%
HR SP-600F-48 48V, 0~12A 0.5% 400mV 90%
16
Input Voltage Range 180~260VAC
Input Frequency 47-63Hz
Inrush Current Cold Start, 60A/230VAC
Output Adjustment Range ±3% Rated Output Voltage By Potential Meter; 20% to 100% By External Control 1V to 5VDC
Line Regulation ≤0.5%
Output Over Load Protection 105%~115% Current Limiting, Delay Shutdown
Output Over Voltage Protection 110%~135% Rated-Output Voltage
Output Short Circuit Protection Delay Shutdown
Rise, Hold Up Time 250mS, 20mS at Full Load (typical)
Hi-pot Isolation I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG:0.5KVAC
Operating Temperature Range -10ºC to +50ºC @ 100%, -20ºC@80%,+65ºC@50% Load
Storage Temperature Range -40ºC to +85ºC, 0 to 95%RH (Non-Condensing)
Safety Standards UL60950-1, TUV EN60950-1
EMC standards EN55022 class B, EN61000-3-2,3
EN61000-4-2,3,4,5,6,8,11,ENV50204
Cooling Method Forced Air Cooling By Built-in DC Fan, Cooling Fan ON/OFF Auto Control
Weight 2.5 Kg/pcs
PF>0.98@230VAC
EMI Meets EN55022(CISPR22) Class B
Low Power Consumption
Approvals: UL/CUL/ TUV/CB/CE
Forced air Cooling By Built-in DC fan
Built-in Remote Sense Function
Built-in Remote ON/OFF Control
Built-in Power Good Signal Output
Can adjust From 20% to 100% Output Voltage By External Control 1V to 5VDC
Protections: Over Load/Over Voltage/Over Temp./ Short Circuit
100% Full Load High Temperature Burn-in Test
2 years Warranty
Product model DC Output Load Regulation R&N Efficiency
HR SP-800F-12 12V, 0~66A 0.5% 120mV 85%
HR SP-800F-15 15V, 0~53A 0.5% 150mV 86%
HR SP-800F-24 24V, 0~33A 0.5% 200mV 89%
HR SP-800F-48 48V, 0~16A 0.5% 400mV 90%
17
Input Voltage Range 85-364VAC; 120-370VDC
Input Frequency 47-63Hz
Inrush Current Cold Start 25A/115VAC, 50A/230VAC
Output Adjustment Range CH1: -5%-+10% Rated Output Voltage
Line Regulation ≤0.5%
Output Over Load Protection 105%~150% Hiccup Mode, Auto-recovery
Output Over Voltage Protection CH1: 115%~135% Rated Output Voltage
Output Short Circuit Protection Hiccup Mode, Auto-recovery
Rise, Hold Up Time 50mS, 20mS at Full Load (Typical)
Hi-pot Isolation I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG:0.5KVAC
Operating Temperature Range 0 ºC to +45 ºC @ 100%, -10ºC@80%,+60ºC@60% Load
Storage Temperature Range -40ºC to +85ºC, 0 to 95%RH (Non-Condensing)
Safety Standards UL60950-1 TUV EN60950-1
EN55022 class B, EN61000-3-2,3 EMC standards
EN61000-4-2,3,4,5,6,8,11,ENV50204
Cooling Method Free Air Cooling Convenction
Weight 0.54 Kg/pcs
Universal Input 85 to 264 VAC
EMI Meets EN55022(CIPR22)
Low Power Consumption
Approvals: UL/ CUL / TUV / CB / CE
Protections: Over Load /Over Voltage / Short Circuit
100% Full Load High Temperature Burn in Test
2 Years Warranty
Product model DC Output Load Regulation R&N Efficiency Max Output
HR D-60F-A
5V, 0.3~6A 1% 75mV
74% 56W 12v, 0.2~4A 6% 120mV
HR D-60F-B
5V, 0.3~6A 1% 75mV
77% 58W 24V, 0.2~ 2.2A 5% 150mV
18
Input Voltage Range 88~132VAC/176~264VAC Selectable By Switch
Input Frequency 47-63Hz
Inrush Current Cold Start, 30A/115VAC,50A/230VAC
Output Adjustment Range CH1: -5%~+10% Rated Output Voltage
Line Regulation ≤0.5%
Output Over Load Protection 105%~135% AC recycle To Re-start
Output Over Voltage Protection CH1: 115%~135% Rated Output Voltage
Output Short Circuit Protection Shut Off, AC recycle Tor Re-Start
Rise, Hold Up Time 50mS, 20mS at Full Load (Typical)
Hi-pot Isolation I/P-O/P: 3KVAC, I/P-FG 1.5KVAC, O/P-FG: 0.5KVAC
Operating Temperature Range 0ºC to +50ºC @100%, -10ºC@80%, +60ºC@60% Load
Storage Temperature Range -40ºC to +85ºC, 0 to 95%RH (Non-Condensing)
Safety Standards UL60950-1, TUV EN60950-1
EMC standards EN55022 class B, EN61000-3-2,3
EN61000-4-2,3,4,5,6,8,11,ENV50204
Cooling Method Free Air Cooling Convenction
Weight 0.82 Kg/pcs
AC Input Range Selectable By Switch
EMI Meets EN55022(CISPR22) Class B
LOW Power Consumption
Approvals: UL/CUL/TUV/CB/CE
Protections: Over Load/Over Voltage/Short Circuit
100% Full Load High Temperature Burn-in Test
2 Years Warranty
Product model DC Output Load Regulation R&N Efficiency Max Output
HR D-120F-A
5V, 2~12A 1% 50mV
78% 120W 12V, 0.5~5A 6% 100mV
HR D-120F-B
5V, 2~10A 1% 50mV
80% 126W 24, 0.4~4A 7% 150mV
19
Universal Input 85 to 264 VAC
EMI Meets EN550022(CISPR22) Class B
Low Power Consumption
Approvals: UL/CUL/ TUV/CB/CE
Protections: Over Load/Over Voltage/ Short Circuit
100% Full Load High Temperature Burn-in Test
2 years Warranty
Product model DC Output Load Regulation R&N Efficiency Max Output
HR T-40F-A
5V, 0.6~5A 1% 75mV
72% 42W 12V, 0.2~3A 6% 120mV
-5V, 0.1~1A 8% 100mV
HR T-40F-B
5V, 0.6~5A 1% 75mV
72% 45W 12V, 0.2~3A 6% 120mV
-12V, 0.1~1A 8% 120mV
HR T-40F-C
5V, 0.6~5A 1% 75mV
45W 72% 15V, 0.2~2A 6% 120mV
-15V, 0.1~1A 6% 120mV
Input Voltage Range 85~264VAC: 120~370VDC
Input Frequency 47-63Hz
Inrush Current Cold Start, 15A/115VAC, 25A/230VAC
Output Adjustment Range CH1: -5%~+10% Rated Output Voltage
Line Regulation ≤0.5%
Output Over Load Protection 105%~150% Hiccup Mode, Auto-recovery
Output Over Voltage Protection 115%~135% Rated-Output Voltage
Output Short Circuit Protection Hiccup Mode, Auto-recovery
Rise, Hold Up Time 50mS, 20mS at Full Load (typical)
Hi-pot Isolation I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG:0.5KVAC
Operating Temperature Range 0ºC to +50ºC @ 100%, -10ºC@80%,+60C@60% Load
Storage Temperature Range -40ºC to +85ºC, 0 to 95%RH (Non-Condensing)
Safety Standards UL60950-1 TUV EN60950-1
EMC standards EN55022 class B, EN61000-3-2,3
EN61000-4-2,3,4,5,6,8,11,ENV50204
Cooling Method Free Air Cooling Convenction
Weight 0.44 Kg/pcs
20
Universal Input 85 to 264 VAC
EMI Meets EN55022(CISPR22) Class B
Low Power Consumption
Approvals: UL/CUL/ TUV/CB/CE
Protections: Over Load/Over Voltage/Over Temp./ Short Circuit
100% Full Load High Temperature Burn-in Test
2 years Warranty
Product model DC Output Load Regulation R&N Efficiency Max Output
HR T-60F-A
5V, 0.5~7A 1% 75mV
73% 58W 12V, 0.2~3.5A 6% 100mV
-5V, 0~1A 6% 100mV
HR T-60F-B
5V, 0.5~7A 1% 75mV
77% 61W 12V, 0.2~3.5A 6% 100mV
-12V, 0~1A 6% 100mV
HR T-60F-C
5V, 0.5~7A 1% 75mV
77% 63W 15V, 0.2~3A 6% 100mV
-15V, 0~1A 6% 100mV
Input Voltage Range 88~264VAC; 120-370VDC
Input Frequency 47-63Hz
Inrush Current Cold Start, 25A/115VAC, 50A/230VAC
Output Adjustment Range CH1: -5%~+10% Rated Output Voltage
Line Regulation ≤0.5%
Output Over Load Protection 105%~150% Shut Off, AC recycle To Re-Start
Output Over Voltage Protection CH1: 115%~135% Rated-Output Voltage
Output Short Circuit Protection Shut Off, AC recycle To Re-Start
Rise, Hold Up Time 50mS, 20mS at Full Load (typical)
Hi-pot Isolation I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG:0.5KVAC
Operating Temperature Range 0ºC to +45ºC @ 100%, -10ºC@80%,+60ºC@60% Load
Storage Temperature Range -40ºC to +85ºC, 0 to 95%RH (Non-Condensing)
Safety Standards UL60950-1 TUV EN60950-1
EMC standards EN55022 class B, EN61000-3-2,3
EN61000-4-2,3,4,5,6,8,11,ENV50204
Cooling Method Free Air Cooling Convenction
Weight 0.55 Kg/pcs
21
Universal Input 85 to 264 VAC
EMI Meets EN55022(CISPR22) Class B
Low Power Consumption
Approvals: UL/CUL/ TUV/CB/CE
Protections: Over Load/Over Voltage/Short Circuit
100% Full Load High Temperature Burn-in Test
2 years Warranty
Input Voltage Range 88~132VAC/176~264VAC Selectable by Switch
Input Frequency 47-63Hz
Inrush Current Cold Start, 30A/115VAC, 50A/230VAC
Output Adjustment Range CH1: -5%~+10% Rated Output Voltage
Line Regulation ≤0.5%
Output Over Load Protection 105%~135% Shut Off, AC recycle To Re-Start
Output Over Voltage Protection CH1: 115%~135% Rated-Output Voltage
Output Short Circuit Protection Shut Off, AC recycle To Re-Start
Rise, Hold Up Time 50mS, 20mS at Full Load (typical)
Hi-pot Isolation I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG:0.5KVAC
Operating Temperature Range 0ºC to +50ºC @ 100%, -10ºC@80%,+60ºC@60% Load
Storage Temperature Range -40ºC to +85ºC, 0 to 95%RH (Non-Condensing)
Safety Standards UL60950-1 TUV EN60950-1
EMC standards EN55022 class B, EN61000-3-2,3
EN61000-4-2,3,4,5,6,8,11,ENV50204
Cooling Method Free Air Cooling Convenction
Weight 0.83 Kg/pcs
Product model DC Output Load Regulation R&N Efficiency Max Output
HR T-120F-A
5V, 2~12A 1% 75mV
77% 120W 12V, 2~12A 6% 100mV
-5V, 2~12A 6% 75mV
HR T-120F-B
5V, 2~12A 1% 75mV
77% 121W 12V, 2~12A 6% 100mV
-12V, 2~12A 6% 100mV
HR T-120F-C
5V, 2~12A 1% 75mV
76% 118W 15V, 2~12A +10%, -5% 120mV
-15V, 2~12A +10%, -5% 120mV
HR T-120F-D
5V, 2~12A 1% 75mV
80% 118W 12V, 2~12A 2~12A 6% 100mV
24V, 2~12A 6% 150mV
22
Input Voltage Range 85-364Vac: 120-370VDC
Input Frequency 47-63Hz
Inrush Current Cold Start 25A/115VAC, 50A/230VAC
Output Adjustment Range CH1: -5%~+10% Rated Output Voltage
Line Regulation ≤0.5%
Output Over Load Protection 105%~150% Hiccup Mode, Auto-recovery
Output Over Voltage Protection CH1: 115%~135% Rated Output Voltage
Output Short Circuit Protection Hiccup Mode, Auto-recovery
Rise, Hold Up Time 50mS, 20mS at Full Load (Typical)
Hi-pot Isolation I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG:0.5KVAC
Operating Temperature Range 0ºC to +45ºC @ 100%, 10ºC@80%,+60ºC@60% Load
Storage Temperature Range -40ºC to +85ºC, 0 to 95%RH (Non-Condensing)
Safety Standards UL60950-1 TUV EN60950-1
EMC standards EN55022 class B, EN61000-3-2,3
EN61000-4-2,3,4,5,6,8,11,ENV50204
Cooling Method Free Air Cooling Convenction
Weight 0.56 Kg/pcs
Universal Input 85 to 264 VAC
EMI Meets EN55022(CISPR22) Class B
Low Power Consumption
Approvals; UL/TUV/CB/CE
Protections: Over Load/ Over Voltage/ Short Circuit
100% Full Load High Temperature Burn-in Test
2 Years Warranty
Product model DC Output Load Regulation R&N Efficiency Max Output
HR Q-60F-A
5V, 0.5~8A 1% 75
71 60W 12V, 0.1~3A 6% 120
-5V, 0~1A 5% 100
-12V, 0~1A 5% 120
HR Q-60F-B
5V, 0.5~8A 1% 75
73 60W 15V, 0.1~3A +8%, -4% 120
-5V, 0~1A 5% 100
-15V, 0~1A 55 120
HR Q-60F-C
5V, 0.5~8A 1% 75
62W 76 12V, 0.1~3A 6% 120
24V, 0.1~1.5A +8%, -4% 150
-12V, 0~1A 5% 120
23
Input Voltage Range 88~132VAC/176~264VAC Selectable By Switch
Input Frequency 47-63Hz
Inrush Current Cold Start, 30A/115VAC,50A/230VAC
Output Adjustment Range CH1: -5%~+10% Rated Output Voltage
Line Regulation ≤0.5%
Output Over Load Protection 105%~135% AC recycle To Re-start
Output Over Voltage Protection CH1: 115%~135% Rated Output Voltage
Output Short Circuit Protection Shut Off, AC recycle Tor Re-Start
Rise, Hold Up Time 50mS, 20mS at Full Load (Typical)
Hi-pot Isolation I/P-O/P: 3KVAC, I/P-FG 1.5KVAC, O/P-FG: 0.5KVAC
Operating Temperature Range 0ºC to +50ºC @100%, -10ºC@80%, +60ºC@60% Load
Storage Temperature Range -40ºC to +85ºC, 0 to 95%RH (Non-Condensing)
Safety Standards UL60950-1 TUV EN60950-1
EMC standards EN55022 class B, EN61000-3-2,3
EN61000-4-2,3,4,5,6,8,11,ENV50204
Cooling Method Free Air Cooling Convenction
Weight 0.86 Kg/pcs
AC Input Range Selectable By Switch
EMI Meets EN55022(CISPR22) Class B
Low Power Consumption
Approvals: Ul/CUL/TUV/CB/CE
Protections: Over Load / Over Voltage / Short Circuit
100% Full Load High Temperature Burn-in Test
2 Years Warranty
Product model DC Output Load Regulation R & N Efficiency Max Output
HR Q-120F-B
5V, 2~12A 1% 75Mv
77% 120W 12V, 0.5~5A 6% 100Mv
-5V, 0.2~1A 6% 75Mv
-12V, 0.2~1 6% 100Mv
HR Q-120F-C
5V, 12~12A 1% 75Mv
76% 123W 15V, 0.5~5A 6% 120Mv
-5V, 0.2~1A 6% 75Mv
-15V, 0.2~1A +10%, -5% 120Mv
HR Q-120F-D
5V, 2~12A 1% 75Mv
124W 80% 12V, 0.2~5A 6% 100Mv
24V, 0.2~2A 6% 150Mv
-12V, 0.2~1A 6% 100Mv
24
25
Input Voltage Normal 100 ~ 240Vac
Operating 90~ 264Vac
Inrush Current 35A@230Vac full load cold start
Overload Protection 105% ~ 150%
Constant current limiting, auto-recovery
Over voltage protection 115% ~ 135% rated output voltage
Operating Temperature -25ºC ~ 70ºC (refer to output derating curve)
Storage temperature -40ºC ~ 85ºC
Safety standard EN60950 / UL508
MTBF 200kHrs at 25ºC
EMC standards EN55022 class B
EN61000 - 6 - 2
Withstand Voltage
I/P - O/P: 3kVac, 1 min
I/P - FG: 1.5kVac, 1 min
O/P - FG: 0.5kVac, 1 min
Weight 0.31 Kg/pcs
Universal AC input / full range
Power on indication
Air cooling
Protections: Overload / Over Voltage / Over temperature / Short Circuit
100% full load burn-in test
Size (H x W x D): 126 mm x 34 mm x 102 mm
3 Years Warranty
Product model Output Voltage Tolerance R & N Efficiency Max Watt DC adjustment range
HDA-45-5 5V, 0~5A ± 2% 50mV 81% 4W 5V ~ 5.5V
HDA-45-12 12V, 0~3.5A ± 2% 100mV 85% 45W 12V ~ 14V
HDA-45-24 24V, 0 ~ 2.0A ±2% 120mV 87% 45W 24V ~ 28V
HDA-45-48 48V, 0 ~ 1.0A ±2% 200mV 89% 45W 48V ~ 53V
26
Input Voltage Normal 100 ~ 240Vac
Operating 90~ 264Vac
Inrush Current 35A@230Vac full load cold start
Overload Protection 105% ~ 150%
Constant current limiting, auto-recovery
Over voltage protection 115% ~ 135% rated output voltage
Operating Temperature -25ºC ~ 70ºC (refer to output derating curve)
Storage temperature -40ºC ~ 85ºC
Safety standard EN60950 / UL508
MTBF 200kHrs at 25ºC
EMC standards EN55022 class B
EN61000 - 6 - 2
Withstand Voltage
I/P - O/P: 3kVac, 1 min
I/P - FG: 1.5kVac, 1 min
O/P - FG: 0.5kVac, 1 min
Weight 0.36 Kg/pcs
Universal AC input / full range
Power on indication
Air cooling
Protections: Overload / Over Voltage / Over temperature / Short Circuit
100% full load burn-in test
Size (H x W x D): 126 mm x 34 mm x 102 mm
3 Years Warranty
Product model Output Voltage Tolerance R & N Efficiency Max Watt DC adjustment range
HDA-75-5 5V, 0~5A ± 2% 50mV 82% 75W 5V ~ 5.5V
HDA-75-12 12V, 0~3.5A ± 2% 100mV 86% 75W 12V ~ 14V
HDA-75-24 24V, 0 ~ 2.0A ±2% 120mV 88% 75W 24V ~ 28V
HDA-75-48 48V, 0 ~ 1.0A ±2% 200mV 90% 75W 48V ~ 53V
27
Input Voltage Normal 100 ~ 240Vac
Operating 90~ 264Vac
Inrush Current 40A @ 230 Vac
20A @ 115Vac full load cold start
Overload Protection 105% ~ 150%
Constant current limiting, auto-recovery
Over voltage protection 120% ~ 140% rated output voltage
Operating Temperature -25ºC ~ 70ºC (refer to output derating curve)
Safety standard EN60950 / UL508
MTBF 200kHrs at 25ºC
EMC standards
EN55022 class B
EN61000 - 6 - 2
EN61000 - 3 -2. 3
Withstand Voltage
I/P - O/P: 3kVac, 1 min
I/P - FG: 1.5kVac, 1 min
O/P - FG: 0.5kVac, 1 min
Weight 0.7 Kg/pcs
Universal AC input / full range
PF>0.99 @ 115 Vac, > 0.96 @ 230 Vac
High efficiency, hight reliability
Power on indication
Air cooling
Protections: Overload / Over Voltage / Over temperature / Short Circuit
100% full load burn-in test
Size (H x W x D): 124 mm x 40 mm x 118 mm
3 Years Warranty
Product model Output Voltage Tolerance R & N Efficiency DC adjustment range Max Watt
HDA-120-12 12V, 0~9A ± 2% 100mV 87% 12V ~ 14V 120W
HDA-120-24 24V, 0 ~ 5A ±2% 100mV 89% 24V ~ 28V 120W
HDA-120-48 48V, 0 ~ 2.5A ±2% 120mV 89% 48V ~ 53V 120W
28
Input Voltage Normal 100 ~ 240Vac
Operating 90~ 264Vac
Inrush Current 40A @ 230 Vac
20A @ 115Vac full load cold start
Overload Protection 105% ~ 150%
Constant current limiting, auto-recovery
Over voltage protection 120% ~ 140% rated output voltage
Operating Temperature -25ºC ~ 70ºC (refer to output derating curve)
Safety standard EN60950 / UL508
MTBF 200kHrs at 25ºC
EMC standards
EN55022 class B
EN61000 - 6 - 2
EN61000 - 3 -2. 3
Withstand Voltage
I/P - O/P: 3kVac, 1 min
I/P - FG: 1.5kVac, 1 min
O/P - FG: 0.5kVac, 1 min
Weight 0.7 Kg/pcs
Universal AC input / full range
PF>0.99 @ 115 Vac, > 0.96 @ 230 Vac
High efficiency, hight reliability
Power on indication
Air cooling
Protections: Overload / Over Voltage / Over temperature / Short Circuit
100% full load burn-in test
Size (H x W x D): 124 mm x 62 mm x 119 mm
3 Years Warranty
Product model Output Voltage Tolerance R & N Efficiency DC adjustment range Max Watt
HDA-150-12 12V, 0~13A ± 2% 100mV 88% 12V ~ 14V 150W
HDA-120-24 24V, 0 ~ 6.3A ±2% 100mV 90% 24V ~ 28V 150W
HDA-120-48 48V, 0 ~ 3.2A ±2% 120mV 91% 48V ~ 53V 150W
29
Input Voltage Normal 100 ~ 240Vac
Operating 90~ 264Vac
Inrush Current 40A @ 230 Vac
20A @ 115Vac full load cold start
Overload Protection 105% ~ 150%
Constant current limiting, auto-recovery
Over voltage protection 120% ~ 140% rated output voltage
Operating Temperature -25ºC ~ 70ºC (refer to output derating curve)
Safety standard EN60950 / UL508
MTBF 200kHrs at 25ºC
EMC standards
EN55022 class B
EN61000 - 6 - 2
EN61000 - 3 -2. 3
Withstand Voltage
I/P - O/P: 3kVac, 1 min
I/P - FG: 1.5kVac, 1 min
O/P - FG: 0.5kVac, 1 min
Weight 0.81 Kg/pcs
Universal AC input / full range
PF>0.99 @ 115 Vac, > 0.96 @ 230 Vac
High efficiency, hight reliability
Power on indication
Air cooling
Protections: Overload / Over Voltage / Over temperature / Short Circuit
100% full load burn-in test
Size (H x W x D): 124 mm x 62 mm x 119 mm
3 Years Warranty
Product model Output Voltage Tolerance R & N Efficiency DC adjustment range Max Watt
HDA-240-12 12V, 0~16A ± 2% 100mV 89% 12V ~ 14V 240W
HDA-240-24 24V, 0 ~ 10A ±2% 100mV 91% 24V ~ 28V 240W
HDA-240-48 48V, 0 ~ 5A ±2% 150mV 92% 48V ~ 53V 150W
30
Input Voltage Normal 100 ~ 240Vac
Operating 90~ 264Vac
Inrush Current 20A @ 230 Vac
12A @ 115Vac full load cold start
Overload Protection 105% ~ 150%
Constant current limiting, auto-recovery
Over voltage protection 120% ~ 140% rated output voltage
Operating Temperature -25ºC ~ 70ºC (refer to output derating curve)
Safety standard EN60950 / UL508
MTBF 200kHrs at 25ºC
EMC standards
EN55022 class B
EN61000 - 6 - 2
EN61000 - 3 -2. 3
Withstand Voltage
I/P - O/P: 3kVac, 1 min
I/P - FG: 1.5kVac, 1 min
O/P - FG: 0.5kVac, 1 min
Weight 0.94 Kg/pcs
Universal AC input / full range
PF>0.99 @ 115 Vac, > 0.96 @ 230 Vac
High efficiency, hight reliability
Power on indication
Air cooling
Protections: Overload / Over Voltage / Over temperature / Short Circuit
100% full load burn-in test
Size (H x W x D): 124 mm x 83 mm x 128 mm
3 Years Warranty
Product model Output Voltage Tolerance R & N Efficiency DC adjustment range Max Watt
HDA-480-24 24V, 0 ~ 20A ±2% 100mV 92% 24V ~ 28V 240W
HDA-480-48 48V, 0 ~ 10A ±2% 150mV 93% 48V ~ 53V 150W
31
Input Voltage Normal 100 ~ 240Vac
Operating 85 ~ 264Vac
Input Frequency 47 ~ 63Hz
Inrush Current 15A @ 100 Vac
30A @ 200 Vac
Over Voltage Protection 120% ~ 140% rated output voltage
Overload Protection > 110% hiccup mode
Hold up time 30ms typ.
Operating Temperature -10ºC ~ 70ºC
Storage Temperature -20ºC ~ 75ºC
Operating Humidity 20% ~ 90% RH, non-condensing
Storage Humidity 20% ~ 90% RH, non-condensing
Safety Standard EN60950 / UL508
MTBF 200kHrs at 25ºC
EMC standards EN55022 class B
EN61000 - 6 - 2
I/P - O/P: 3kVac, 1 min
Withstand Voltage I/P - FG: 1.5kVac, 1 min
O/P - FG: 0.5kVac, 1 min
Weight 0.26 Kg/pcs
Universal AC input / full range
Power on indication
Air cooling
Plastic case and low cost
Protections: Over Load / Over Voltage / Short Circuit / Short Circuit
Double Isolation, high security
100% full load burn-in test
Size (H x W x D): 91 mm x 71 mm x 57 mm
3 Years Warranty
Product model Output Voltage Tolerance R & N Efficiency Max Watt
HDR-60-12 12V / 5A ± 5% 50mV 86% 60W
HDR-60-24 24V / 2.5A ± 5% 50mV 86% 60W
32
33
Input Voltage Range 90~277Vac
Input Frequency 47-63Hz
Input Current 0,4A Max
Inrush Current 20A Max (Cold Start)
Set Up Time 2s Max at Nominal Line
Constant Current Precision ±5% Max
Dielectric Withstand I/P - O/P: 3750 Vac
Operating Temperature -35 ºC to 70 ºC
Derateing Linearly from 100% load at 60 ºC to 80% load at 70 ºC
Storage Temperature -40 ºC to 85ºC
Protections OLP, OVP, Short Circuit
Over Current Protections
95% - 105%
Constant Current Auto-recovery Mode
Safety Standards
UL8750,UL1310 Class2,EN61347-1,
EN61347-2-13,UL 1012, IP67
EMC standards EN55015, EN61000-3-2,3
EN61000-4-2,3,4,5,6,8,11,EN61547
Standard Output Cable UL Rated,18 - 16# AWG
Weight 0.2 Kg/pcs
Universal input.
UL1310 Class2 power unit.
Waterproof: IP67 | Cooling by free air convection.
Suitable for LED lighting and moving sign applications
Protections: Over Load / Over Voltage / Short Circuit
Built - in active PFC function. PF>0.92 for 100% load
3 Years Warranty
Product model Output Voltage Range
(VDC)
Output Max
Current
R & N
(Max)
Efficiency
(Typ.)
Max Watt PF
(Typ.)
HWP/HQP/HLP - 14 - 300mA 35 - 48V 300mA 4.0V 82 14.0W 0.9
HWP/HQP/HLP - 14 - 350mA 25 - 36V 350mA 3.0V 82 12.6W 0.9
HWP/HQP/HLP - 14 - 500mA 18 - 28V 500mA 2.5V 82 14.0W 0.9
HWP/HQP/HLP - 14 - 700mA 16 - 20V 700mA 2.0V 82 14.0W 0.9
HWP/HQP/HLP - 14 - 700mA 16 - 24V 700mA 2.0V 84 16.8W 0.92
HWP/HQP/HLP - 14 - 500mA 25 - 36 500mA 3.0V 84 18.0W 0.92
HWP/HQP/HLP - 14 - 350mA 35 - 54V 350mA 4.0V 84 18.9W 0.92
HWP/HQP/HLP - 14 - 700mA 18 - 30V 700mA 2.5V 84 21.0W 0.92
34
Input Voltage Range 90 ~ 277Vac
Input Frequency 47 ~ 63Hz
Input Current 0,6A Max
Inrush Current 20A Max (Cold Start)
Set Up Time 2s Max at Nominal Line
Constant Current Precision ±5% Max
Dielectric Withstand I/P - O/P: 3750 Vac
Operating Temperature -35 ºC to 70 ºC
Derating Linearly from 100% load at 60 ºC to 80% load at 70 ºC
Storage Temperature -40 ºC to +85ºC
Protections OTP, OLP, OVP, Short Circuit
Over Current Protections 95% - 105% Constant Current Auto-recovery Mode
Safety Standards UL8750,UL1310 Class2,EN61347-1,EN61347-2-13,UL 1012, IP67
EMC standards EN55015, EN61000-3-2,3
EN61000-4-2,3,4,5,6,8,11,EN61547
Standard Output Cable UL Rated,18 - 16# AWG
Weight 0.25 Kg/pcs
Universal input.
UL1310 Class2 power unit. (Except>60Vdc)
Meet to 4kV surge (IEC61000-4-5)
Suitable for LED lighting and moving sign applications
Protections: Over Load / Over Voltage / Over Temperature / Short Circuit
Built - in active PFC function. PF>0.92 for 100% load
Cooling by free air convection
3 Years Warranty
Product model Output Voltage Range Output Max R & N Efficiency
Max Watt PF
HPE - 25 - 350mA 48 - 72V 0.35A 1.5V 85 25.2W 0.92
HPE - 25 - 500mA 33 - 50V 0.50A 2.0V 85 25.0W 0.92
HPE - 25 - 700mA 24 - 36V 0.70A 2.5V 85 25.2W 0.92
HPE - 25 - 1.05A 15 - 24V 1.05A 3.5V 85 25.2W 0.92
HPE - 25 - 1.40A 11 - 18V 1.40A 5.0V 85 25.2W 0.92
HPE - 35 - 350mA 65 - 100V 0.35A 8.0V 86 35.0W 0.95
HPE - 35 - 500mA 48 - 72V 0.5A 1.5V 86 36.0W 0.95
HPE - 35 - 700mA 33 - 50V 0.70A 2.0V 86 35.0W 0.95
HPE - 35 - 1.05A 21 - 33V 1.05A 2.5V 86 34.7W 0.95
HPE - 35 - 1.40A 15 - 24V 1.40A 3.5V 86 33.6W 0.95
HPE - 35 - 1.75A 13 - 20V 1.75A 5.0V 86 35.0W 0.95
35
Input Voltage Range 90 ~ 277Vac
Input Frequency 47 ~ 63Hz
Input Current 0,9A Max
Inrush Current 30A Max (Cold Start)
Set Up Time 2s Max at Nominal Line
Constant Current Precision ±5% Max
Dielectric Withstand I/P - O/P: 3750 Vac; I/P-FG: 1875Vac
Operating Temperature -35 ºC to 70 ºC
Derating Linearly from 100% load at 60 ºC to 80% load at 70 ºC
Storage Temperature -40 ºC to +85ºC
Protections OTP, OLP, OVP, Short Circuit
Over Current Protections 95% - 105% Constant Current Auto-recovery Mode
Safety Standards UL8750,UL1310 Class2,EN61347-1,EN61347-2-13,UL 1012, IP67
EMC standards EN55015, EN61000-3-2,3
EN61000-4-2,3,4,5,6,8,11,EN61547
Standard Output Cable UL Rated,18 - 16# AWG
Weight 0.5 Kg/pcs
Universal input.
UL1310 Class2 power unit. (Except>60Vdc).
Meet to 4kV surge (IEC61000-4-5).
Suitable for LED lighting and moving sign applications.
Protections: Over Load / Over Voltage / Over Temperature / Short Circuit.
Built - in active PFC function. PF>0.92 for 100% load.
Waterproof: IP67.
Cooling by free air convection.
3 Years Warranty.
Product model Output Voltage Range
(VDC)
Output Max
Current
R & N
(Max)
Efficiency
(Typ.)
Max Watt PF
(Typ.)
HWP - 30 - 350mA 63 - 90V 0.35A 7.0V 85 31.5W 0.92
HWP - 30 - 500mA 36 - 60V 0.50A 5.0V 85 30.0W 0.92
HWP - 30 - 700mA 30 - 48V 0.70A 4.0V 85 33.6W 0.92
HWP - 30 - 1.05A 18 - 30V 1.05A 2.5V 85 30.0W 0.92
HWP - 30 - 1.40A 15 - 24V 1.40A 2.0V 85 33.6W 0.92
HWP - 30 - 1.75A 12 - 18V 1.75A 1.5V 85 31.5W 0.92
HWP - 50 - 500mA 65 - 100V 0.50A 8.0V 88 50.0W 0.95
HWP - 50 - 700mA 45 - 72V 0.70A 6.0V 88 50.4W 0.95
HWP - 50 - 1.05mA 30 - 48V 1.05A 4.0V 88 50.4W 0.95
HWP - 50 - 1.40A 20 - 36V 1.40A 3.0V 88 50.4W 0.95
HWP - 50 - 1.75A 18 - 30V 1.75A 2.5V 88 52.5W 0.95
HWP - 50 - 2.10A 15 - 24V 2.10A 2.0V 88 50.4W 0.95
HWP - 50 - 2.80A 12 - 18V 2.80A 1.5V 88 50.4W 0.95
36
Input Voltage Range 90 ~ 277Vac
Input Frequency 47 ~ 63Hz
Input Current 1,4A Max
Inrush Current 50A Max (Cold Start)
Set Up Time 2s Max at Nominal Line
Constant Current Precision ±5% Max
Dielectric Withstand I/P - O/P: 3750 Vac; I/P-FG: 1875Vac
Operating Temperature -35 ºC to 70 ºC
Derating Linearly from 100% load at 60 ºC to 80% load at 70 ºC
Storage Temperature -40 ºC to +85ºC
Protections OTP, OLP, OVP, Short Circuit
Over Current Protections 95% - 105% Constant Current Auto-recovery Mode
Safety Standards UL8750,UL1310 Class2,EN61347-1,EN61347-2-13,UL 1012, IP67
EMC standards EN55015, EN61000-3-2,3
EN61000-4-2,3,4,5,6,8,11,EN61547
Standard Output Cable UL Rated,18 - 16# AWG
Weight 1 Kg/pcs
Universal input.
Meet to 4kV surge (IEC61000-4-5).
Suitable for LED lighting and moving sign applications.
Protections: Over Load / Over Voltage / Over Temperature / Short Circuit.
Built - in active PFC function. PF>0.92 for 100% load.
Waterproof: IP67.
Cooling by free air convection.
3 Years Warranty.
Product model Output Voltage Range
(VDC)
Output Max
Current
R & N
(Max)
Efficiency
(Typ.)
Max Watt PF
(Typ.)
HWPG - 60 - 1.05A 35 - 54V 1.05A 4.0V 90 56.7W 0.95
HWPG - 60 - 1.75A 25 - 36V 1.75A 3.0V 90 60.0W 0.95
HWPG - 60 - 2.10A 18 - 30V 2.10A 2.5V 90 60.0W 0.95
HWPG - 60 - 2.45A 16 - 24V 2.45A 2.0V 90 58.0W 0.95
HWPG - 80 - 1.40A 35 - 54V 1.40A 4.0V 90 75.6W 0.95
HWPG - 80 - 1.75A 35 - 48V 1.75A 4.0V 90 80.0W 0.95
HWPG - 80 - 2.10A 25 - 36V 2.10A 3.0V 90 75.6W 0.95
HWPG - 80 - 2.80A 18 - 30V 2.80A 2.5V 90 80.0W 0.95
HWPG - 80 - 3.20A 16 - 24V 3.20A 2.0V 90 76.8W 0.95
HWPG - 80 - 3.75A 16 - 21V 3.75A 2.0V 90 80.0W 0.95
HWPG - 100 - 1.75A 35 - 54V 1.75A 4.0V 90 94.5W 0.95
HWPG - 100 - 2.10A 35 - 48V 2.10A 4.0V 90 100.0W 0.95
HWPG - 100 - 2.45A 25 - 40V 2.45A 3.0V 90 98.0W 0.95
HWPG - 100 - 2.80A 25 - 36V 2.80A 3.0V 90 100.W 0.95
HWPG - 100 - 3.20A 18 - 30V 3.20A 2.5V 90 96.0W 0.95
HWPG - 100 - 4.20A 16 - 24V 4.20A 2.0V 90 100.0W 0.95
37
Input Voltage Range 90 ~ 277Vac
Input Frequency 47 ~ 63Hz
Input Current 2,2A Max
Inrush Current 100A Max (Cold Start)
Set Up Time 2s Max at Nominal Line
Constant Current Precision ±5% Max
Dielectric Withstand I/P - O/P: 3750 Vac; I/P-FG: 1875Vac
Operating Temperature -35 ºC to 70 ºC
Derating Linearly from 100% load at 60 ºC to 80% load at 70 ºC
Storage Temperature -40 ºC to +85ºC
Protections OTP, OLP, OVP, Short Circuit
Over Current Protections
95% - 105% Constant Current
Auto-recovery Mode
Safety Standards
UL8750,UL1310 Class2,EN61347-1,
EN61347-2-13,UL 1012, IP67
EMC standards EN55015, EN61000-3-2,3
EN61000-4-2,3,4,5,6,8,11,EN61547
Standard Output Cable UL Rated,18 - 16# AWG
Weight 1,5 Kg/pcs
Universal input.
Meet to 4kV surge (IEC61000-4-5).
Suitable for LED lighting and moving sign applications.
Protections: Over Load / Over Voltage / Over Temperature / Short Circuit.
Built - in active PFC function. PF>0.92 for 100% load.
Waterproof: IP67.
Cooling by free air convection.
3 Years Warranty.
Product model Output Voltage Range
(VDC)
Output Max
Current
R & N
(Max)
Efficiency
(Typ.)
Max Watt PF
(Typ.)
HWP - 120 - 2.20A 35 - 54V 2.20A 360mV 93 120W 0.95
HWP - 120 - 2.50A 31 - 48V 2.50A 360mV 93 120W 0.95
HWP - 120 - 2.85A 27 - 42V 2.85A 300mV 92 120W 0.95
HWP - 120 - 3.30A 23 - 36V 3.30A 300mV 92 120W 0.95
HWP - 120 - 5.00A 15 - 24V 5.00A 240mV 91 120W 0.95
HWP - 150 - 2.80A 35 - 54V 2.80A 360mV 93 150W 0.98
HWP - 150 - 3.12A 31 - 48V 3.12A 360mV 93 150W 0.98
HWP - 150 - 3.57A 27 - 42V 3.57A 300mV 92 150W 0.98
HWP - 150 - 3.75A 26 - 40V 3.75A 300mV 92 150W 0.95
HWP - 150 - 4.16A 23 - 36V 4.16A 300mV 91 150W 0.98
HWP - 150 - 5.00A 19 - 30V 5.00A 250mV 92 150W 0.98
HWP - 150 - 6.25A 15 - 24V 6.25A 240mV 92 150W 0.98
38
Input Voltage Range 90 ~ 277Vac
Input Frequency 47 ~ 63Hz
Input Current 2,8A Max
Inrush Current 100A Max (Cold Start)
Set Up Time 2s Max at Nominal Line
Constant Current Precision ±5% Max
Dielectric Withstand I/P - O/P: 3750 Vac; I/P-FG: 1875Vac
Operating Temperature -35 ºC to 70 ºC
Derating Linearly from 100% load at 60 ºC to 80% load at 70 ºC
Storage Temperature -40 ºC to +85ºC
Protections OTP, OLP, OVP, Short Circuit
Over Current Protections 95% - 105% Constant Current
Auto-recovery Mode
Safety Standards UL8750,UL1310 Class2,EN61347-1,
EN61347-2-13,UL 1012, IP67
EMC standards EN55015, EN61000-3-2,3
EN61000-4-2,3,4,5,6,8,11,EN61547
Standard Output Cable UL Rated,18 - 16# AWG
Weight 0,5 - 1,5 Kg/pcs for different model
Universal input.
Meet to 4kV surge (IEC61000-4-5).
Suitable for LED lighting and moving sign applications.
Protections: Over Load / Over Voltage / Over Temperature / Short Circuit.
Built - in active PFC function. PF>0.92 for 100% load.
Waterproof: IP67.
Cooling by free air convection.
3 Years Warranty.
Product model Output Voltage Range
(VDC)
Output Max
Current
R & N
(Max)
Efficiency
(Typ.)
Max Watt PF
(Typ.)
HWP - 60D - 350mA 65 - 105V 350mA 6.0V 90 60W 0.95
HWP - 100D - 350mA 82 - 130V 350mA 7.5V 90 100W 0.95
HWP - 100D - 1.0A 35 - 51V 1.0A 3.0V 90 100W 0.95
HWP - 120D - 1.2A 35 -51V 1.2A 3.0V 90 120W 0.95
HWP - 150D - 350mA 100 - 160V 350mA 10.0V 90 150W 0.95
HWP - 150M - 350mA 30 - 54V 350mA 3.0V 89 150W 0.95
HWP - 200M - 350mA 30 - 54V 350mA 3.0V 89 200W 0.95
39
40
Input Voltage Range 90 ~ 277Vac
Input Frequency 47 ~ 63Hz
Input Current 1,2A Max
Inrush Current 40A Max (Cold Start)
Set Up Time 3s Max at Nominal Line
Constant Current Precision ±5% Max
Dielectric Withstand I/P - O/P: 3750 Vac; I/P-FG: 1875Vac
Operating Temperature -35 ºC to 60 ºc
Derating Linearly from 100% load at 50 ºC to 80% load at 60 ºC
Storage Temperature -40 ºC to +85ºC
Protections OTP, OLP, OVP, Short Circuit
Over Current Protections 110% - 150% Constant Current
Auto-recovery Mode
Safety Standards UL8750,UL1310 Class2,EN61347-1,
EN61347-2-13,UL 1012, IP67
EMC standards EN55015, EN61000-3-2,3
EN61000-4-2,3,4,5,6,8,11,EN61547
Standard Output Cable UL Rated,18 - 16# AWG
Weight 0,8 Kg/pcs for different model
Universal input.
Meet to 4kV surge (IEC61000-4-5).
Suitable for LED lighting and moving sign applications.
Protections: Over Load / Over Voltage / Over Temperature / Short Circuit.
Built - in active PFC function. PF>0.95 for 100% load.
UL1310 Class2 power unit.
Waterproof: IP67.
Cooling by free air convection.
3 Years Warranty.
Product model Output Voltage Range
(VDC)
Output Max
Current
R & N
(Max)
Efficiency
(Typ.)
Max Watt PF
(Typ.)
HLA - 45 - 12 12V 4.09A 150mV 83 45W 0.93
HLA - 45 - 24 24V 2.14A 250mV 85 45W 0.93
HLA - 45 - 36 36V 1.66A 250mV 85 45W 0.93
HLA - 45 - 48 48V 1.12A 250mV 85 45W 0.93
HLA - 60 - 12 12V 5.45A 150mV 85 60W 0.95
HLA - 60 - 24 24V 3.42A 250mV 87 60W 0.95
HLA - 60 - 36 36V 2.66A 250mV 87 60W 0.95
HLA - 60 - 48 48V 1.80A 250mV 87 60W 0.95
41
Input Voltage Range 90 ~ 277Vac
Input Frequency 47 ~ 63Hz
Input Current 1,2A Max
Inrush Current 40A Max (Cold Start)
Set Up Time 3s Max at Nominal Line
Constant Current Precision ±5% Max
Dielectric Withstand I/P - O/P: 3750 Vac; I/P-FG: 1875Vac
Operating Temperature -35 ºC to 70 ºc
Derating Linearly from 100% load at 50 ºC to 80% load at 70 ºC
Storage Temperature -40 ºC to +85ºC
Protections OTP, OLP, OVP, Short Circuit
Over Current Protections 110% - 150% Constant Current
Auto-recovery Mode
Safety Standards UL8750,UL1310 Class2,EN61347-1,
EN61347-2-13,UL 1012, IP67
EMC standards EN55015, EN61000-3-2,3
EN61000-4-2,3,4,5,6,8,11,EN61547
Standard Output Cable UL Rated,18 - 16# AWG
Weight 1 Kg/pcs for different model
Universal input.
Meet to 4kV surge (IEC61000-4-5).
Suitable for LED lighting and moving sign applications.
Protections: Over Load / Over Voltage / Over Temperature / Short Circuit.
Built - in active PFC function. PF>0.95 for 100% load.
UL1310 Class2 power unit.
Waterproof: IP67.
Cooling by free air convection.
3 Years Warranty.
Product model Output Voltage Range
(VDC)
Output Max
Current
R & N
(Max)
Efficiency
(Typ.)
Max Watt PF
(Typ.)
HWPV - 75 - 12 12V 6.25A 120mV 85 75W 0.95
HWPV - 75 - 24 24V 3.12A 150mV 87 75W 0.95
HWPV - 75 - 30 30V 2.50A 180mV 87 75W 0.95
HWPV - 75 - 36 36V 2.08A 200mV 87 75W 0.95
HWPV - 75 - 42 42V 1.78A 250mV 87 75W 0.95
HWPV - 75 - 48 48V 1.56A 280mV 87 75W 0.95
HWPV - 75 - 54 54V 1.38A 300mV 87 75W 0.95
42
Input Voltage Range 90 ~ 277Vac
Input Frequency 47 ~ 63Hz
Input Current 1,5A Max
Inrush Current 40A Max (Cold Start)
Set Up Time 3s Max at Nominal Line
Constant Current Precision ±5% Max
Dielectric Withstand I/P - O/P: 3750 Vac; I/P-FG: 1875Vac
Operating Temperature -35 ºC to 60 ºc
Derating Linearly from 100% load at 50 ºC to 80% load at 60 ºc
Storage Temperature -40 ºC to +85ºC
Protections OTP, OLP, OVP, Short Circuit
Over Current Protections 110% - 150% Constant Current
Auto-recovery Mode
Safety Standards UL8750,UL1310 Class2,EN61347-1,
EN61347-2-13,UL 1012, IP67
EMC standards EN55015, EN61000-3-2,3
EN61000-4-2,3,4,5,6,8,11,EN61547
Standard Output Cable UL Rated,18 - 14# AWG
Weight 1 Kg/pcs for different model
Universal input.
Meet to 4kV surge (IEC61000-4-5).
Suitable for LED lighting and moving sign applications.
Protections: Over Load / Over Voltage / Over Temperature / Short Circuit.
Built - in active PFC function. PF>0.95 for 100% load.
UL1310 Class2 power unit.
Waterproof: IP67.
Cooling by free air convection.
3 Years Warranty.
Product model Output Voltage Range
(VDC)
Output Max
Current
R & N
(Max)
Efficiency
(Typ.)
Max Watt PF
(Typ.)
ELA - 100 - 12 12V 6.67A 150mV 88 80W 0.95
ELA - 100 - 15 15V 5.33A 150mV 88 80W 0.95
ELA - 100 - 18 18V 5.00A 200mV 89 90W 0.95
ELA - 100 - 20 20V 4.80A 200mV 89 96W 0.95
ELA - 100 - 24 24V 4.00A 200mV 90 96W 0.95
ELA - 100 - 30 30V 3.20A 200mV 90 96W 0.95
ELA - 100 - 36 36V 2.66A 250mV 91 96W 0.95
ELA - 100 - 42 42V 2.28A 250mV 91 96W 0.95
ELA - 100 - 48 48V 2.00A 250mV 91 96W 0.95
43
Input Voltage Range 90 ~ 277Vac
Input Frequency 47 ~ 63Hz
Input Current 2.2A Max
Inrush Current 100A Max (Cold Start)
Set Up Time 2s Max at Nominal Line
Constant Current Precision ±5% Max
Dielectric Withstand I/P - O/P: 3750 Vac; I/P-FG: 1875Vac
Operating Temperature -35 ºC to 60 ºc
Derating Linearly from 100% load at 50 ºC to 80% load at 70 ºc
Storage Temperature -40 ºC to +85ºC
Protections OTP, OLP, OVP, Short Circuit
Over Current Protections 110% - 145% Constant Current
Auto-recovery Mode
Safety Standards UL8750,UL1310 Class2,EN61347-1,
EN61347-2-13,UL 1012, IP67
EMC standards EN55015, EN61000-3-2,3
EN61000-4-2,3,4,5,6,8,11,EN61547
Standard Output Cable UL Rated,18 - 14# AWG
Weight 1,5 Kg/pcs for different model
Universal input.
Meet to 4kV surge (IEC61000-4-5).
Suitable for LED lighting and moving sign applications.
Protections: Over Load / Over Voltage / Over Temperature / Short Circuit.
Built - in active PFC function. PF>0.95 for 100% load.
Waterproof: IP67.
Cooling by free air convection.
3 Years Warranty.
Product model Output Voltage Range
(VDC)
Output Max
Current
R & N
(Max)
Efficiency
(Typ.)
Max Watt PF
(Typ.)
HWPV - 120 - 24 24V 5.00A 240mV 91 120W 0.95
HWPV - 120 - 36 36V 3.30A 300mV 92 120W 0.95
HWPV - 120 - 42 42V 2.85A 300mV 92 120W 0.95
HWPV - 120 - 48 48V 2.50A 360mV 93 120W 0.95
HWPV - 120 - 54 54V 2.20A 360mV 93 120W 0.95
HWPV - 150 - 24 24V 6.25A 240mV 91 150W 0.98
HWPV - 150 - 30 30V 5.00A 250mV 92 150W 0.98
HWPV - 150 - 36 36V 4.16A 300mV 91 150W 0.98
HWPV - 150 - 40 40V 3.75A 300mV 92 150W 0.95
HWPV - 150 - 42 42V 3.57A 300mV 92 150W 0.98
HWPV - 150 - 48 48V 3.12A 360mV 93 150W 0.98
HWPV - 150 - 54 54V 2.80A 360mV 93 150W 0.98
44
45
Input Voltage Range 85~264Vac; 120~370VDC
Input Frequency 47-63Hz
Inrush Current 25A / 115Vac, 50A / 230Vac (Cold Start)
DC Output Tolerance ±2% Rated Output Voltage
Line Regulation ≤0.5%
Output Over Load Protection 105%~150% Hiccup Mode, Auto-recovery
Output Short Circuit Protection Hiccup Mode, Auto-recovery
Rise, Hold Up Time 50mS, 20mS at Full Load (Typical)
Hi-pot Isolation I/P-O/P, I/P-FG:1.5KVac, O/P-FG: 0.5KVac
Operating Temperature Range 0ºC to 45ºC @ 100%, -10ºC @80%, 60ºC @ 60% Load
Stage Temperature Range -40ºC to 85ºC, 0 to 95% RH (Non-Condensing)
Safety Standards Design Refer To UL60950-1, EN60950-1
EMC standards Design Refer To EN55022 class A
Cooling Method Free Air Cooling Convection
Weight 0.12 Kg/pcs
Universal input 85 to 264 Vac
Low Cost, High Reliability
Low Power Consumption
Built-In EMI Filter
Protections: Over Load / Short Circuit
100% Full Load High Temperature Burn-in Test
1 Years Warranty
Product model
Output Voltage Range Load
Regulation
Efficiency R & N
(Max)
HOFS - 25 - 3.3 3.3V, 0~5A 1% 66% 75 mV
HOFS - 25 - 5 5V, 0~5A 1% 74% 75mV
HOFS - 25 - 7.5 7.5V, - 0~3.3A 1% 76% 75mV
HOFS - 25 - 9 9V, 0~2.8A 1% 77% 100mV
HOFS - 25 - 12 12V, 0~2.1A 0.5% 78% 100mV
HOFS - 25 - 13.5 13.5V, 0~1.9A 0.5% 78% 100mV
HOFS - 25 - 15 15V, 0~1.7A 0.5% 78% 100mV
HOFS - 25 - 24 24V, 0~1A 0.5% 79% 100mV
HOFS - 25 - 27 27V, 0~0.9A 0.5% 100mV 79%
HOFS - 25 - 48 48V, 0~0.5A 0.5% 250mV 80%
46
Input Voltage Range 90~264Vac; 120~370VDC
Input Frequency 47-63Hz
Inrush Current 25A / 115Vac, 50A / 230Vac (Cold Start)
DC Output Tolerance ±10% Rated Output Voltage
Line Regulation ≤0.5%
Output Over Load Protection 110%~150% Hiccup Mode, Auto-recovery
Output Over Voltage Protection 115%~135% Rated Output Voltage
Output Short Circuit Protection Hiccup Mode, Auto-recovery
Rise, Hold Up Time 50mS, 20mS at Full Load (Typical)
Hi-pot Isolation I/P-O/P, I/P-FG:1.5KVac, O/P-FG: 0.5KVac
Operating Temperature Range 0ºC to 45ºC @ 100%, -10ºC @80%, 60ºC @ 60% Load
Stage Temperature Range -40ºC to 85ºC, 0 to 95% RH (Non-Condensing)
Safety Standards Design Refer To UL60950-1, EN60950-1
Design Refer To EN55022 class A EMC standards
Cooling Method Free Air Cooling Convection
Weight 0.22 Kg/pcs
Universal input 90 to 264 Vac
Low Cost, High Reliability
Low Power Consumption
Built-In EMI Filter
Protections: Over Load / Over Voltage / Short Circuit
100% Full Load High Temperature Burn-in Test
1 Years Warranty
Product model
Output Voltage Range Load
Regulation
Efficiency R & N
(Max)
HOFS - 45 - 3.3 3.3V, 0~8A 1% 69% 75mV
HOFS - 45 - 5 5V, 0~8A 1% 74% 75mV
HOFS - 45 - 7.5 7.5V, - 0~5.4A 1% 75% 75mV
HOFS - 45 - 9 9V, 0~5A 1% 76% 100mV
HOFS - 45 - 12 12V, 0~3.7A 0.5% 76% 100mV
HOFS - 45 - 13.5 13.5V, 0~3.3A 0.5% 77% 100mV
HOFS - 45 - 15 15V, 0~3A 0.5% 77% 100mV
HOFS - 45 - 24 24V, 0~1.9A 0.5% 78% 100mV
HOFS - 45 - 27 27V, 0~1.7A 0.5% 100mV 78%
HOFS - 45 - 48 48V, 0~1A 0.5% 100mV 79%
47
Input Voltage Range 90~264Vac; 120~370VDC
Input Frequency 47-63Hz
Inrush Current 20A / 115Vac, 50A / 230Vac (Cold Start)
DC Output Tolerance ±10% Rated Output Voltage
Line Regulation ≤0.5%
Output Over Load Protection 110%~150% Hiccup Mode, Auto-recovery
Output Over Voltage Protection 115%~135% Rated Output Voltage
Output Short Circuit Protection Hiccup Mode, Auto-recovery
Rise, Hold Up Time 50mS, 20mS at Full Load (Typical)
Hi-pot Isolation I/P-O/P, I/P-FG:1.5KVac, O/P-FG: 0.5KVac
Operating Temperature Range 0ºC to 45ºC @ 100%, -10ºC @80%, 60ºC @ 60% Load
Stage Temperature Range -40ºC to 85ºC, 0 to 95% RH (Non-Condensing)
Safety Standards Design Refer To UL60950-1, EN60950-1
Design Refer To EN55022 class A EMC standards
Cooling Method Free Air Cooling Convection
Weight 0.22 Kg/pcs
Universal input 90 to 264 Vac
Low Cost, High Reliability
Low Power Consumption
Built-In EMI Filter
Protections: Over Load / Over Voltage / Short Circuit
100% Full Load High Temperature Burn-in Test
1 Years Warranty
Product model
Output Voltage Range Load
Regulation
Efficiency R & N
(Max)
HOFS - 65 - 3.3 3.3V, 0~12A 1% 69% 75 mV
HOFS - 65 - 5 5V, 0~12A 1% 76% 75mV
HOFS - 65 - 7.5 7.5V, - 0~8A 1% 79% 75mV
HOFS - 65 - 9 9V, 0~7A 1% 79% 100mV
HOFS - 65 - 12 12V, 0~7A 0.5% 79% 100mV
HOFS - 65 - 13.5 13.5V, 0~4.7 0.5% 79% 100mV
HOFS - 65 - 15 15V, 0~4.2A 0.5% 79% 100mV
HOFS - 65 - 24 24V, 0~2.7A 0.5% 80% 100mV
HOFS - 65 - 27 27V, 0~2.4A 0.5% 100mV 80%
HOFS - 65 - 48 48V, 0~1.35A 0.5% 100mV 81%
48
Input Voltage Range 88~264Vac; 127~370VDC
Input Frequency 47-63Hz
Inrush Current 60A / 230Vac (Cold Start)
Leakage Current Less Than 2mA at 240Vac
DC Output Tolerance ±5% ~ +10% Rated Output Voltage
Line Regulation ≤0.5%
Output Over Load Protection 105%~150% Hiccup Mode, Auto-recovery
Output Over Voltage Protection 115%~135% Rated Output Voltage
Output Short Circuit Protection Constant Current, Auto-recovery
Rise, Hold Up Time 30mS, 28mS at Full Load (Typical)
Hi-pot Isolation I/P-O/P, I/P-FG:1.5KVac, O/P-FG: 0.5KVac
Operating Temperature Range 0ºC to 50ºC @ 100%, -10ºC @80%, 60ºC @ 60% Load
Stage Temperature Range -40ºC to 85ºC, 0 to 95% RH (Non-Condensing)
Safety Standards Design Refer To UL60950-1, EN60950-1
Design Referer To EN55022 class A EMC standards
Cooling Method Free Air Cooling Convection
Weight 0.51 Kg/pcs
Universal input 90 to 264 Vac
PF>0.98@115Vac; PF>0.95@230Vac
Low Power Consumption
Built-In EMI Filter
Protections: Over Load / Over Voltage / Short Circuit
100% Full Load High Temperature Burn-in Test
1 Years Warranty
Product model
Output Voltage Range Load
Regulation
Efficiency R & N
(Max)
HOFSP - 100 - 3.3 3.3V, 0~20A 1% 70% 100mV
HOFSP - 100 - 5 5V, 0~20A 1% 76% 100mV
HOFSP - 100 - 7.5 7.5V, - 0~13.5A 1% 77% 100mV
HOFSP - 100 - 9 9V, 0~11.2A 1% 79% 100mV
HOFSP - 100 - 12 12V, 0~8.5A 1% 80% 100mV
HOFSP - 100 - 13.5 13.5V, 0~7.5A 1% 80% 100mV
HOFSP - 100 - 15 15V, 0~6.7A 1% 81% 100mV
HOFSP - 100 - 24 24V, 0~4.2A 0.5% 84% 150mV
HOFSP - 100 - 27 27V, 0~3.8A 0.5% 150mV 84%
HOFSP - 100 - 48 48V, 0~2.1A 0.5% 250mV 84%