V10 Drawn by Bernard 5/10/2009 Feuille 1 /1 N/D Z.I Perwez, B-1360 Perwez, Belgium Tel +32 81 26 50 80 Fax +32 81 26 50 90 Email [email protected] GB www.ocea.be Cable Junctions- Logic Simple Cables arriving from the control panel - plant room The connections between motor cable and the cables from the control panel (5 x 1.5mm² + 24VDC power supply) are to soldered and be made in a resin sealed junction box The cables must be in a manhole or chamber so that easy access is available. Water tight corrugated pipe which must go above the water level. Pipe must be fixed to the sleeve with a stainless steel color clamp. This scenario applies to paved or other types of pool surrounds. The motor cable does not exceed 3M. Avoid sharp bends in the pipes.