c00287657

154
application notes HP OpenView Storage Management Appliance software Event code definitions Product Version: 2.1 Third Edition (January 2005) Part Number: AA-RTDKC-TE This document describes the event codes in notification messages generated by the HP OpenView Storage Management Appliance software 2.1. Additional information and other HP OpenView documentation are available at http://h18006.www1.hp.com/products/sanworks/managementappliance .

Transcript of c00287657

Page 1: c00287657

application notes

HP OpenViewStorage Management Appliance

softwareEvent code definitions

Product Version: 2.1

Third Edition (January 2005)

Part Number: AA-RTDKC-TE

This document describes the event codes in notification messages generated by the HP OpenView Storage Management Appliance software 2.1.

Additional information and other HP OpenView documentation are available at http://h18006.www1.hp.com/products/sanworks/managementappliance.

Page 2: c00287657

2 Event code definitions application notes

© 2002-2005 Hewlett-Packard Company Development Company, L.P.

Hewlett-Packard Company makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.

This document contains proprietary information, which is protected by copyright. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of Hewlett-Packard. The information contained in this document is subject to change without notice.

Compaq Computer Corporation is a wholly-owned subsidiary of Hewlett-Packard Company.

All product names mentioned herein may be trademarks of their respective companies.

Hewlett-Packard Company shall not be liable for technical or editorial errors or omissions contained herein. The information is provided “as is” without warranty of any kind and is subject to change without notice. The warranties for Hewlett-Packard Company products are set forth in the express limited warranty statements accompanying such products. Nothing herein should be construed as constituting an additional warranty.

Printed in the U.S.A.

Storage Management Appliance software Event code definitions application notesThird Edition (January 2005)Part Number: AA-RTDKC-TE

Page 3: c00287657

About this document

3Event code definitions application notes

About this documentThis document lists and describes the event codes displayed by the HP OpenView Storage Management Appliance. It covers the following topics:

■ Introduction, page 4

■ Storage Management Appliance event codes, page 5

■ Storage Management Appliance audit codes, page 7

■ NetApp Filer event codes, page 10

■ HP StorageWorks and McData switch event codes, page 12

■ HP StorageWorks SAN and Brocade switch event codes, page 14

■ Cisco MDS switch event codes, page 16

■ HSG Element Manager event codes, page 27

■ Command View EVA event codes, page 34

Intended audienceThis document is intended for customers using the Storage Management Appliance software 2.1. It has been developed for use by storage and system administrators who are experienced with:

■ Managing storage area networks (SANs)

■ Running a Storage Management Appliance

Related documentationRefer to the following documentation for more information about the Storage Management Appliance software:

■ HP OpenView Storage Management Appliance software update installation card

■ HP OpenView Storage Management Appliance software user guide

■ HP OpenView Storage Management Appliance software release notes

■ HP OpenView Storage Management Appliance software online help

Additional documentation, including white papers and best-practices documents, is available from the HP website at http://h18006.www1.hp.com/products/sanworks/managementappliance/documentation.html.

Page 4: c00287657

Introduction

4 Event code definitions application notes

Introduction The Storage Management Appliance can generate notification messages to any number of users in response to events. A notification message, which includes the source of the event, date, time, event code, and event description, can be sent to a standard e-mail address or to an e-mail pager address. This document provides a list of the events logged by the Storage Management Appliance.

The events are presented in tables, with one table for each application or vendor.

Each table contains the following columns:

■ Event ID—Numeric code that identifies the event specific to the event’s source.

■ Event Code—Hexadecimal code that identifies an event type in notification messages and in the Storage Management Appliance Event Log or Audit Log.

■ Severity—Single-digit code indicating the event severity or potential impact on Storage Management Appliance operations. (See Table 1 for more information.)

■ Description—Text describing the event. Event details are provided by the source of the event. In this document, event details are expressed as %1, %2, and so on.

Table 1 describes the event severity codes.

Table 1: Event Severity Codes

Event Severity Code Name Description

0 Unknown Severity cannot be determined.1 Other Can be one of several possible severity

conditions. Refer to the event code description for details.

2 Information Event is generally part of normal operation. 3 Warning Further action is optional.4 Minor Further action is required but the situation is not

considered serious. 5 Major Action should be taken immediately. 6 Critical Action required to avoid a significant impact on

operations. 7 Fatal An error occurred and no action can be taken to

avoid or mitigate the immediate impact.

Page 5: c00287657

Storage Management Appliance event codes

5Event code definitions application notes

Storage Management Appliance event codesThe Storage Management Appliance’s core services—discovery, event notification, and automation—generate the events listed in Table 2. The system records these events in the Storage Management Appliance Event Log.

Table 2: Storage Management Appliance Event Codes

Event ID Event Code Severity Description202 880A00CA 2 Discovery %1 started.

203 880A00CB 2 Discovery %1 completed.

204 880A00CC 2 New device found: %1.

205 880A00CD 2 Device %1 unreachable for %2 day(s).

206 880A00CE 2 Device %1 unreachable for %2 week(s).

408 880A0198 3 Notification for user %1 has been disabled. This user was the sole recipient of event notifications from %2.

700 880A02BC 2 Received a SNMP Trap from %1. The enterprise OID is %2, GenericTrap is %3, SpecificTrap is %4.

701 880A02BD 3 The Management Appliance event log is 80% full.

702 880A02BE 6 The Management Appliance event log is full.

703 880A02BF 3 The Management Appliance audit log is 80% full.

704 880A02C0 6 The Management Appliance audit log is full.

800 880A0320 7 Automation Manager experienced the following abnormal operation: %1.

801 880A0321 7 Automation Manager experienced the following database failure: %1.

802 880A0322 2 Event process %1 ran in policy %2 on Management Appliance %3 completed with state %4. Process started on %5 and ended on %6 with %7 return code. Policy finished with status: %8.

803 880A0323 2 Event process %1 ran in policy %2 triggered on an event %3 logged by %4.

804 880A0324 3 Event process %1 ran in policy %2 on Management Appliance %3 completed with state %4. Process started on %5 and ended on %6 with %7 return code. Policy finished with status: %8.

805 880A0325 2 Action process %1 ran in policy %2 on Management Appliance %3 completed with state %4. Process started on %5 and ended on %6 with %7 return code. Policy finished with status: %8.

806 880A0326 3 Action process %1 ran in policy %2 on Management Appliance %3 completed with state %4. Process started on %5 and ended on %6 with %7 return code. Policy finished with status: %8.

807 880A0327 2 %1 policy has been submitted successfully.

808 880A0328 2 Event process %1 in policy %2 was satisfied when the %3 value of enterprise OID %4 was received in a SNMP Trap.

1014 880A03F6 2 %1 service started.

Page 6: c00287657

Storage Management Appliance event codes

6 Event code definitions application notes

1015 880A03F7 2 %1 service stopped.

1016 880A03F8 2 %1 service: Handler not installed.

1017 880A03F9 2 %1 service: Bad service request.

Table 2: Storage Management Appliance Event Codes (Continued)

Event ID Event Code Severity Description

Page 7: c00287657

Storage Management Appliance audit codes

7Event code definitions application notes

Storage Management Appliance audit codesThe Storage Management Appliance generates audits in response to most user-initiated activities. Activities such as creating or running a discovery generate audits that are recorded in the Storage Management Appliance Audit Log. Table 3 describes the Storage Management Appliance audit codes.

Table 3: Storage Management Appliance Audit Codes

Event ID Event Code Severity Description100 8C0A0064 2 Installation of %1 on appliance %2.

101 8C0A0065 2 Removal of %1 from appliance %2.

150 8C0A0096 2 Deletion of %1 device.

151 8C0A0097 2 Launch of %1 URL.

152 8C0A0098 2 Modification of %1 device.

207 8C0A00CF 2 Creation of discovery named %1.

208 8C0A00D0 2 Deletion of discovery named %1.

209 8C0A00D1 2 Modification of discovery named %1.

210 8C0A00D2 2 Enabling of schedule for discovery named %1.

211 8C0A00D3 2 Disabling of schedule for discovery named %1.

212 8C0A00D4 2 Discovery named %1 requested to start.

213 8C0A00D5 2 Discovery named %1 requested to stop.

300 8C0A012C 2 Creation of remote access entry for Host: %1, Application: %2, Domain Name: %3, Username: %4.

301 8C0A012D 2 Modification of remote access entry for Host: %1, Application: %2, Domain Name: %3, Username: %4.

302 8C0A012E 2 Deletion of remote access entry for Host: %1, Application: %2, Domain Name: %3, Username: %4.

303 8C0A012F 2 Modification of %1 license.

304 8C0A0130 2 Creation of %1 license.

305 8C0A0131 2 Deletion of %1 license.

306 8C0A0132 2 Modification of %1 license.

307 8C0A0133 2 Download of %1 license.

308 8C0A0134 2 Clearing of %1 license.

309 8C0A0135 2 Download of event log.

310 8C0A0136 2 Clearing of event log.

311 8C0A0137 2 Modification of event log properties.

312 8C0A0138 2 Acknowledgement of events in the event log.

400 8C0A0190 2 Deletion of user %1.

401 8C0A0191 2 Importing of user %1.

402 8C0A0192 2 Creation of user %1.

403 8C0A0193 2 Changing password for user %1.

404 8C0A0194 2 Modification of user %1 properties.

405 8C0A0195 2 Modification of user %1 notification properties for the following devices: %2.

406 8C0A0196 2 Transfer of user %1 notification settings to user %2.

Page 8: c00287657

Storage Management Appliance audit codes

8 Event code definitions application notes

407 8C0A0197 2 Deletion of notification settings from user %1 and transferred to user %2.

500 8C0A01F4 2 Starting backup to network share %1.

501 8C0A01F5 2 Completion of backup operation that was started to network share %1. See %2 file on Management Appliance %3 for details.

502 8C0A01F6 2 Cancellation of backup operation that was started to network share %1. See %2 file on Management Appliance %3 for details.

600 8C0A0258 2 Starting restore operation from network share %1.

601 8C0A0259 2 Completion of restore operation that was started to network share %1. See %2 file on Management Appliance %3 for details.

602 8C0A025A 2 Cancellation of restore operation that was started from network share %1. See %2 file on Management Appliance %3 for details.

603 8C0A025B 2 Clearing of backup log %1.

604 8C0A025C 2 Clearing of restore log %1.

605 8C0A025D 2 Clearing of notification log %1.

900 8C0A0384 2 Starting %1.

901 8C0A0385 2 Stopping %1.

904 8C0A0388 2 Changing date/time to %1.

905 8C0A0389 2 Changing time zone to %1.

906 8C0A038A 2 Modification of SNTP time server - Enabled: %1, Server:%2, Frequency:%3.

950 8C0A03B6 2 Launching of HSV element manager.

951 8C0A03B7 2 Launching of HSG Element Manager.

952 8C0A03B8 2 Launching of VersaStor.

953 8C0A03B9 2 Launching of Automation.

954 8C0A03BA 2 Launching of Management Agents.

960 8C0A03C0 2 Launching of Network View.

961 8C0A03C1 2 Launching of Secure Path Manager.

962 8C0A03C2 2 Launching of Continuous Access.

963 8C0A03C3 2 Launching of Business Copy.

964 8C0A03C4 2 Launching of Storage Allocation Reporter.

965 8C0A03C5 2 Launching of Storage Provisioner.

970 8C0A03CA 2 Modification of IP address configuration.

971 8C0A03CB 2 Modification of DNS server configuration.

972 8C0A03CC 2 Modification of WINS server configuration.

980 8C0A03D4 2 Modification of Administration Web Site properties.

981 8C0A03D5 2 Modification of Global Network settings.

982 8C0A03D6 2 Modification of Telnet Administration configuration.

1000 8C0A03E8 2 Changing Management Appliance name to %1.

Table 3: Storage Management Appliance Audit Codes (Continued)

Event ID Event Code Severity Description

Page 9: c00287657

Storage Management Appliance audit codes

9Event code definitions application notes

1001 8C0A03E9 2 Changing Management Appliance membership to workgroup %1.

1002 8C0A03EA 2 Changing Management Appliance membership to domain %1.

1003 8C0A03EB 2 Shutdown of Management Appliance.

1004 8C0A03EC 2 Changing domain/workgroup membership.

1005 8C0A03ED 2 Restarting Management Appliance.

1006 8C0A03EE 2 Scheduling Management Appliance for %1.

1010 8C0A03F2 2 Configuration of Management Appliance as the first domain controller in the new forest, %1. The new domain name is %2.

1011 8C0A03F3 2 Configuration of Management Appliance as the first domain controller in a new domain tree. The name of the new domain is %1 and has trust link with %2.

1012 8C0A03F4 2 Configuration of Management Appliance as the first domain controller in a new domain. The name of the new domain is %1 and is created in %2 domain.

1013 8C0A03F5 2 Configuration of Management Appliance as an additional domain controller for the domain %1.

1020 8C0A03FC 2 Modification of notification properties for event code %1 on %2.

1021 8C0A03FD 2 Configuration of notification for the following devices: %1.

1022 8C0A03FE 2 Clearing of notification settings for the following devices: %1.

1030 8C0A0406 2 Download of audit log.

1031 8C0A0407 2 Clearing of audit log.

1032 8C0A0408 2 Modification of audit log properties.

1033 8C0A0409 2 Acknowledgement of audits in the audit log.

1040 8C0A0410 2 Trap recipient %1 added.

1041 8C0A0411 2 Trap recipient %1 removed.

1042 8C0A0412 2 SNMP properties modified.

1050 8C0A041A 2 Setting SMTP server to %1.

1055 8C0A041F 2 Logging in of user.

1056 8C0A0420 2 Logging out of user.

1057 8C0A0421 2 Locate appliance ON.

1058 8C0A0422 2 Locate appliance OFF.

1059 8C0A0423 2 Legal notice modified.

1060 8C0A0424 2 Test email sent to %1.

1061 8C0A0425 2 Test trap sent to %1.

1062 8C0A0426 2 Importing of group %1.

1063 8C0A0427 2 Unimporting of group %1.

1064 8C0A0428 2 Modification of group %1 properties.

Table 3: Storage Management Appliance Audit Codes (Continued)

Event ID Event Code Severity Description

Page 10: c00287657

NetApp Filer event codes

10 Event code definitions application notes

NetApp Filer event codesTable 4 describes the events generated by NetApp Filer devices. These events are recorded in the Storage Management Appliance Event Log. Several of the events are associated with user-defined traps, and most indicate a condition that will likely have a negative impact on operations. A small number of events indicate a return to normal operation after a period of abnormal operation.

The Storage Management Appliance supports NetApp MIB version 1.2.

Table 4: NetApp Filer Event Codes

Event ID Event Code Severity Description100 880E0064 2 An unknown trap event was received.

101 880E0065 3 A polling-style trap built by the user using the SNMP traps command on the filer.

102 880E0066 5 Disk Health Monitor reported a Disk Degraded-I/O Event.

103 880E0067 4 Disk Health Monitor reported a Disk Predictive-Failure Event.

104 880E0068 7 A user-defined trap indicating an extremely urgent situation, usually indicating that the system has failed and is shutting down.

105 880E0069 5 A user-defined trap indicating a condition that should be corrected immediately, such as a failed disk.

106 880E006A 6 A user-defined trap indicating a critical condition, such as a hard device error.

107 880E006B 5 A user-defined trap indicating an error condition, such as a mistake in a configuration file.

108 880E006C 4 A user-defined trap indicating a condition which is not an error, but which may require special handling.

109 880E006D 2 A user-defined trap meant to provide information, such as an hourly uptime message.

110 880E006E 1 A user-defined trap used for debugging purposes.

111 880E006F 7 System is shutting down because the system has been running in degraded mode for 24 hours.

112 880E0070 5 One or more disks failed.

113 880E0071 2 The failed disks have been repaired.

114 880E0072 7 Critical chassis or cpu fans have failed and the system is shutting down.

115 880E0073 5 One or more chassis fans failed.

116 880E0074 3 One or more chassis or cpu fans are in warning state.

117 880E0075 2 All fans are repaired.

118 880E0076 7 Critical power supplies or power rails failed and the system is shutting down.

119 880E0077 5 One or more redundant power supplies failed.

120 880E0078 3 One or more power supplies or power rails in warning state.

121 880E0079 2 Previously-failed power supplies or power rails have been repaired.

122 880E007A 4 CPU utilization exceeds 90 percent.

Page 11: c00287657

NetApp Filer event codes

11Event code definitions application notes

123 880E007B 2 CPU utilization has dropped back below 90 percent.

124 880E007C 5 The NVRAM battery is fully discharged.

125 880E007D 4 The charge in the NVRAM battery is low.

126 880E007E 5 A node in a Cluster FailOver configuration failed. Its partner will assume service for the failed node.

127 880E007F 5 The partner has taken over for a failed cluster node.

128 880E0080 2 A cluster node has resumed operation.

129 880E0081 5 At least one volume is more than 98 percent full.

130 880E0082 4 At least one volume is more than 95 percent full.

131 880E0083 2 All volumes are now under 95 percent full.

132 880E0084 7 System temperature is too high to continue operating. The system is shutting down.

133 880E0085 4 System temperature is too high and in the warning level.

134 880E0086 2 System temperature has returned to an acceptable value.

135 880E0087 5 A disk storage shelf reported a fault, probably due to a problem with drive placement, fans, power, or temperature.

136 880E0088 2 A previously-reported shelf fault is now corrected.

137 880E0089 7 The appliance’s overall status changed to ‘nonRecoverable’, indicating a problem so severe that the appliance is shutting down.

138 880E008A 6 The appliance’s overall status changed to ‘critical’, indicating a problem that needs immediate attention.

139 880E008B 4 The appliance’s overall status changed to ‘nonCritical’, indicating a problem that needs attention.

140 880E008C 2 The appliance’s overall status returned to normal.

141 880E008D 2 Cold Start.

142 880E008E 2 Warm Start.

143 880E008F 2 Link Down: %1.

144 880E0090 2 Link Up: %1.

145 880E0091 2 Authorization failure.

146 880e0092 2 EGP Peer down: %1.

Table 4: NetApp Filer Event Codes (Continued)

Event ID Event Code Severity Description

Page 12: c00287657

HP StorageWorks and McData switch event codes

12 Event code definitions application notes

HP StorageWorks and McData switch event codesTable 5 describes events generated by HP StorageWorks switches and McData switches. These events are recorded in the Storage Management Appliance Event Log. Many of the events have several possible states, and each state has an associated severity code.

The Storage Management Appliance supports the following StorageWorks and McData MIB versions:

■ 1.9 for the ED-5000 series

■ 1.10 for the EF-6000 series

■ 1.0 for the ES-1000 series

Table 5: HP StorageWorks and McData Switch Event Codes

Event ID Event Code Possible States Severity Description100 880C0064 N/A 2 An unknown trap event was received.

101 880C0065 onlineofflinetestingfaultyunknown

25270

B_Port Index %2 changed state to %1.%n.A es1000PortBportScn is generated whenever a B_Port changes its operational state.

102 880C0066 onlineofflinetestingfaultyunknown

25270

H_Port Index %2 changed state to %1.%n.A es1000PortHportScn is generated whenever a H_Port changes its operational state.

103 880C0067 activeupdatebusyfailedunknown

2270

Component Code %2 has changed state to %1.%n. A es1000CompScn is generated whenever a COMPONENT status changes its operational state.

104 880C0068 onlineofflinetestingfaultyunknown

25270

Port Index %2 changed state to %1.%nAn ed5000PortScn(1) is generated whenever a Fc_Port changes its operational state.

105 880C0069 activebackupupdatebusyfailedunknown

23270

FRU Code %2 has changed state to %1.%n.An ed5000FruScn(2) is generated whenever a FRU status changes its operational state.

106 880C006A onlineofflinetestingfaultyunknown

25270

Port Index %2 changed state to %1.%n.An ef6000PortScn(1) is generated whenever a Fc_Port changes its operational state.

107 880C006B activebackupupdatebusyfailedunknown

23270

FRU Code %2 has changed state to %1.%n.An ef6000FruScn(2) is generated whenever a FRU status changes its operational state.

Page 13: c00287657

HP StorageWorks and McData switch event codes

13Event code definitions application notes

108 880C006C N/A 2 Device WWN: %1 currently attached to Port %2 has either successfully connected or is currently being rejected due to a Port Binding violation.%n.An ef6000PortBindingViolation(3) is generated whenever the switch detects that a port binding violation occurs.

109 880C006D N/A 2 Threshold Alert.%nef6000PortIndex: %1%nef6000TAIndex: %2%nAn ef6000ThresholdAlert(4) is generated whenever a threshold alert occurs.

113 880C0071 informational 2 Cold Start.

115 880C0073 informational 2 Warm Start.

117 880C0075 warning 3 Link Down: %1.

119 880C0077 informational 2 Link Up: %1.

121 880C0079 warning 3 Authorization failure.

123 880C007B warning 3 EGP Peer down: %1.

Table 5: HP StorageWorks and McData Switch Event Codes (Continued)

Event ID Event Code Possible States Severity Description

Page 14: c00287657

HP StorageWorks SAN and Brocade switch event codes

14 Event code definitions application notes

HP StorageWorks SAN and Brocade switch event codesTable 6 describes the events generated by HP StorageWorks SAN switches and Brocade switches. These events are recorded in the Storage Management Appliance Event Log. Many of these events have several possible states, and each state has an associated severity code.

The Storage Management Appliance supports the StorageWorks SAN and Brocade MIB version 4.0.

Table 6: StorageWorks SAN and Brocade Switch Event Codes

Event ID Event Code Possible States Severity Description100 88020064 informational 2 An unknown trap event was received.

101 88020065 okfaultyunknown

250

Switch is faulty.Faulty reason: %1%nSSN: %2%nGroupName: %3%nGroupType: %4%nGroup MemPosition: %5%nA swFault(1) is generated whenever the diagnostics detects a fault with the switch.

103 88020067 unknownfaultybelow minimumnormalabove maximumabsent

057252

%5 is currently in state %1%n.SSN: %7%nGroupName: %3%nGroupType: %8%nGroup MemPosition: %9%nA swSensorScn(2) is generated whenever an environment sensor changes its operational state. For instance, a fan stops working. The VarBind in the Trap Data Unit shall contain the corresponding instance of the sensor status, sensor index, sensor type, sensor value (reading) and sensor information. Note that the sensor information contains the type of sensor and its number in textual format.

105 88020069 unknownonlineofflinetestingfaulty

02527

Port Index %2 changed state to %1%n.SSN: %3%nGroupName: %3%nGroupType: %5%nGroup MemPosition: %6%nA swFCPortScn(3) is generated whenever an FC_Port changes its operational state. For instance, the FC_Port goes from on-line to offline. The VarBind in the Trap Data Unit shall contain the corresponding instance of the FC_Port's operational status and index.

Page 15: c00287657

HP StorageWorks SAN and Brocade switch event codes

15Event code definitions application notes

107 8802006B criticalerrorwarninginformationaldebug

55322

Event %1: %2 (severity level %3) - %5%nSSN: %6%nGroupName: %7%nGroupType: %8%nGroupMemPosition: %9%nThis trap is generated when an event whose level at or below swEventTrapLevel occurs.

109 8802006D informationalnormalfaulty

227

Fabric Watch has generated an event. %n.Threshold %3 in Class/Area %1 at index %2 has generated event %7 with %5 on %6.%n.This event is %8%n.SSN: %9%nGroupName: %10%nGroupType: %11%nGroupMemPosition: %12%nTrap sent by Fabric Watch to notify of an event.

111 8802006F informational 2 A track change has generated a trap.%1%n.SSN: %2GroupName: %3GroupType: %4GroupMemPosition: %5%nTrap sent for tracking login/logout/config changes.

113 88020071 informational 2 Cold Start.

115 88020073 informational 2 Warm Start.

117 88020075 warning 3 Link Down: %1.

119 88020077 informational 2 Link Up: %1.

121 88020079 informational 3 Authorization failure.

123 8802007B informational 3 EGP Peer down: %1.

Table 6: StorageWorks SAN and Brocade Switch Event Codes (Continued)

Event ID Event Code Possible States Severity Description

Page 16: c00287657

Cisco MDS switch event codes

16 Event code definitions application notes

Cisco MDS switch event codesTable 7 describes events generated by Cisco switches. These events are recorded in the Storage Management Appliance Event Log. Many of the events have several possible states, and each state has an associated severity code.

The Storage Management Appliance (SMA) supports the following Cisco MDS Switches:

■ Cisco MDS 9509

■ Cisco MDS 9506

■ Cisco MDS 9216

■ Cisco MDS 9216A

■ Cisco MDS 9216i

■ Cisco MDS 9120

■ Cisco MDS 9140

The Storage Management Appliance supports the following Cisco MDS 9000 Family MIBs:

■ CISCO-CONFIG-COPY-MIB: Copy features and support

■ CISCO-DM-MIB: Domain Management functions

■ CISCO-ENTITY-FRU-CONTROL-MIB: FRU support MIB

■ CISCO-ENTITY-SENSOR-MIB: Sensor support MIB

■ CISCO-EXT-SCSI-MIB: Extensions to the SCSI MIB

■ CISCO-FC-FE-MIB: Fibre Element management

■ CISCO-FCPING-MIB: Fibre Channel Ping management

■ CISCO-FCS-MIB: Fabric Configuration Server (FCS) management

■ CISCO-FCTRACEROUTE-MIB: Fibre Channel Trace Route functions

■ CISCO-FLASH-MIB: Flash functions and support

■ CISCO-FSPF-MIB: Fabric Shortest Path First (FSPF) functions

■ CISCO-HC-ALARM-MIB: High Capacity Alarm management

■ CISCO-ISCSI-MIB: iSCSI MIB

■ CISCO-NS-MIB: Name Server management

■ CISCO-RF-MIB: Redundancy Framework support

■ CISCO-RSCN-MIB: Registered State Change Notification (RSCN) management

■ CISCO-SCSI-MIB: Cisco version of the SCSI support MIB

■ CISCO-SYSLOG-MIB: System log configuration

■ CISCO-SYSTEM-EXT-MIB: System Extension MIB

■ CISCO-SYSTEM-MIB: System MIB

■ CISCO-VIRTUAL-NW-IF-MIB: Virtual Network Interface Management

■ CISCO-VSAN-MIB: VSAN parameters

■ CISCO-WWNMGR-MIB: World Wide Name (WWN) Manager functions

■ CISCO-ZS-MIB: Zoning Server functions

Page 17: c00287657

Cisco MDS switch event codes

17Event code definitions application notes

Note: You should install HP OpenView Storage Management Appliance software 2.1 Service Pack 2 if you have Cisco MDS 9000 Series Multilayer SAN switches in your SAN and would like to manage their events using the Storage Management Appliance software 2.1 event notification system. For more information, go to the following URL:http://h18006.www1.hp.com/products/sanworks/softwaredrivers/managementappliance/v21-sp2.html.

Table 7: Cisco MDS Switch Event Codes

Event ID Event Code Severity Description1 880D0001 2 ccCopyServerAddress: %1

ccCopyFileName: %2ccCopyState: %3ccCopyTimeStarted: %4ccCopyTimeCompleted: %5ccCopyFailCause: %6A ccCopyCompletion trap is sent at the completion of a config-copy request. The ccCopyFailCause is not instantiated, and hence not included in a trap, when the ccCopyState is success

2 880D0002 3 vsanIndex of the VSAN on which the condition happened: %1cffFcFeElementName: %2If a Domain ID is not configured or assigned on a VSAN, then the switch may isolate E_ports on that VSAN. The conditions are:- If the Domain Manager is enabled on the local switch and its request for a configured static Domain ID is rejected or no other Domain ID is assigned, then the E_ports are isolated.- If the domain manager is not enabled and if a static Domain ID is not configured on the VSAN, then the switch will isolate all of its E_ports on the VSAN.

3 880D0003 3 vsanIndex of the VSAN on which the switch became the Principal Switch: %1WWN of the switch which became the Principal Switch: %2This notification indicates that the sending switch has become the new Principal Switch on a VSAN. This notification is sent soon after its election as the new Principal Switch, i.e., upon expiration of a Principal Switch selection timer which is equal to twice Fabric Stability Timeout value (F_S_TOV).

Page 18: c00287657

Cisco MDS switch event codes

18 Event code definitions application notes

4 880D0004 2 vsanIndex of the VSAN: %1This notification is sent whenever a switch sends or receives a Build Fabric (BF) or a ReConfigure Fabric (RCF) message on a VSAN.A switch can receive or issue a BuildFabric (BF) or a ReConfigureFabric (RCF) message under following conditions: - A new link causes two disjoint fabrics in a VSAN to merge into one fabric. The sent/received message is BF if the Domain ID lists on the disjoint fabric does not overlap and it is RCF if they overlap. - An upsteam principal ISL which connects to Principal switch and other switches in a VSAN fails. BF is issued to see if there is an alternative path to the Principal Switch. If not paths exit, then an RCF is issued. - A switch asks for a different set of Domain IDs than the currently assigned list, the Principal switch would issue an RCF.

5 880D0005 2 cefcModuleOperStatus: %1cefcModuleStatusLastChangeTime: %2This notification is generated when the value of cefcModuleOperStatus changes. It can be utilized by an NMS to update the status of the module it is managing.

6 880D0006 2 cefcFRUPowerOperStatus: %1cefcFRUPowerAdminStatus: %2This notification is generated when the value of cefcModuleOperStatus changes. It can be utilized by an NMS to update the status of the module it is managing.

7 880D0007 2 entPhysicalContainedIn: %1The cecfFRUInserted notification indicates that a FRU was inserted. The varbind for this notification indicates the entPhysicalIndex of the inserted FRU, and the entPhysicalIndex of the FRU's container.

8 880D0008 3 entPhysicalContainedIn: %1The cefcFRURemoved notification indicates that a FRU was removed. The varbind for this notification indicates the entPhysicalIndex of the removed FRU, and the entPhysicalIndex of the FRU's container.

Table 7: Cisco MDS Switch Event Codes

Event ID Event Code Severity Description

Page 19: c00287657

Cisco MDS switch event codes

19Event code definitions application notes

9 880D0009 2 entPhysicalClass: %1entPhysicalVendorType: %2 entPhysicalName: %3entPhysicalModelName: %4cefcPhysicalStatus: %5The cefcUnrecognizedFRU notification indicates that a FRU was inserted whose product ID is not supported. The varbind for this notification indicates the entPhysicalIndex of the inserted FRU, the entPhysicalClass this FRU belongs to, the entPhysicalVendorType of this FRU, the entPhysicalName of the FRU, the entPhysicalModelName of the inserted FRU, and the cefcPhysicalStatus telling the reason code for sending this notification.

10 880D000A 2 cefcFanTrayOperStatus: %1This notification is generated when the value of cefcModuleOperStatus changes.

11 880D000B 2 entSensorThresholdValue: %1entSensorValue: %2The sensor value crossed the threshold listed in entSensorThresholdTable. This notification is generated once each time the sensor value crosses the threshold. The agent implementation guarantees prompt, timely evaluation of threshold and generation of this notification.

12 880D000C 2 ciscoExtScsiLunDiscStatus: %1This notification is generated whenever a Lun discovery cycle is completed.

13 880D000D 2 fcTrunkIfOperStatus: %1fcTrunkIfOperStatusCause: %2fcTrunkIfOperStatusCauseDescr: %3This notification is generated by the agent whenever the fcTrunkifOperStatus object for this trunk interface is about to enter the down state from some other state. This other state is indicated by the included value of fcTrunkifOperStatus.

14 880D000E 2 fcTrunkIfOperStatus: %1fcTrunkIfOperStatusCause: %2fcTrunkIfOperStatusCauseDescr: %3This notification is generated by the agent whenever the fcTrunkifOperStatus object for one of its trunk interfaces has left the down state and transitioned into some other state. This other state is indicated by the included value of fcTrunkifOperStatus.

15 880D000F 2 fcIfElpNbrNodeName: %1fcIfElpNbrPortName: %2fcIfElpRejectReasonCode: %3fcIfElpRejectReasonCodeExpl: %4This notification is generated by the agent whenever this interface received a ELP request and rejected it.

Table 7: Cisco MDS Switch Event Codes

Event ID Event Code Severity Description

Page 20: c00287657

Cisco MDS switch event codes

20 Event code definitions application notes

16 880D0010 2 fcPingAddress: %1fcPingTxPackets: %2fcPingRxPackets: %3This notification is generated whenever a sequence of pings is complete and the corresponding instance of fcPingTrapOnCompletion object has been set to 'true'.

17 880D0011 2 fcsRejReasonCode: %1fcsRejReasonCodeExplanation: %2This notification is generated by the Fabric Configuration Server on this switch whenever it rejects a Fabric Configuration Server request. The Fabric Configuration Server should update the fcsRejReasonCode and fcsRejReasonCodeExplanation objects with the corresponding reason code and reason code explanation before sending the notification.

18 880D0012 2 fcsVsanDiscoveryName: %1This notification is generated by the Fabric Configuration Server when a discovery cycle specified by fcsVsanDiscoveryList2k, fcsVsanDiscoveryList4k and fcsVsanDiscoveryName is completed.

19 880D0013 2 fcTraceRouteTargetAddr: %1fcTraceRouteOperStatus: %2This notification is generated whenever a trace route test is completed and the corresponding instance of fcTraceRouteTrapOnCompletion is set to 'true'.The agent is encouraged to append, at the end of this notification's varbindlist, one varbind for each hop of the traced route. Each such appended varbind would contain an instance of fcTraceRouteHopsHopAddr object. If the number of varbinds required would cause the notification to approach it's maximum size, the number of instances of fcTraceRouteHopsHopAddr will be truncated suitably."

20 880D0014 2 ciscoFlashCopyStatus: %1A ciscoFlashCopyCompletionTrap is sent at the completion of a flash copy operation if such a trap was requested when the operation was initiated.

21 880D0015 2 ciscoFlashPartitioningStatus: %1A ciscoFlashPartitioningCompletionTrap is sent at the completion of a partitioning operation if such a trap was requested when the operation was initiated.

22 880D0016 2 ciscoFlashMiscOpStatus: %1A ciscoFlashPartitioningCompletionTrap is sent at the completion of a partitioning operation if such a trap was requested when the operation was initiated.

Table 7: Cisco MDS Switch Event Codes

Event ID Event Code Severity Description

Page 21: c00287657

Cisco MDS switch event codes

21Event code definitions application notes

23 880D0017 2 ciscoFlashDeviceIndex: %1A ciscoFlashPartitioningCompletionTrap is sent at the completion of a partitioning operation if such a trap was requested when the operation was initiated.

24 880D0018 2 ifIndex: %1notifyVsanIndex: %2fspfDomainId: %3fspfIfNbrDomainId: %4fspfIfNbrState: %5fspfIfPrevNbrState: %6This notification signifies that there has been a change in the state of FSPF neighbors. This is generated when the FSPF state regresses (e.g., goes from Full to init or Down) or progresses (e.g., from any state to Full) to a terminal state. The value of 'fspfIfNbrState' is the state of the neighbor after the change.

25 880D0019 2 cHcAlarmVariable: %1cHcAlarmSampleType: %2cHcAlarmAbsValue: %3cHcAlarmValueStatus: %4cHcAlarmRisingThreshAbsValueLo: %5cHcAlarmRisingThreshAbsValueHi: %6cHcAlarmRisingThresholdValStatus: %7cHcAlarmRisingEventIndex: %8The SNMP notification that is generated when a high capacity alarm entry crosses its rising threshold and generates an event that is configured for sending SNMP traps.The cHcAlarmEntry object instances identified in the OBJECTS clause are from the entry that causes this notification to be generated.

26 880D001A 2 cHcAlarmVariable: %1cHcAlarmSampleType: %2cHcAlarmAbsValue: %3cHcAlarmValueStatus: %4cHcAlarmFallingThreshAbsValueLo: %5cHcAlarmFallingThreshAbsValueHi: %6cHcAlarmFallingThrsholdValStatus: %7cHcAlarmFallingEventIndex: %8The SNMP notification that is generated when a high capacity alarm entry crosses its falling threshold and generates an event that is configured for sending SNMP traps.The cHcAlarmEntry object instances identified in the OBJECTS clause are from the entry that causes this notification to be generated.

Table 7: Cisco MDS Switch Event Codes

Event ID Event Code Severity Description

Page 22: c00287657

Cisco MDS switch event codes

22 Event code definitions application notes

27 880D001B 2 cIscsiIntrLoginFailures: %1cIscsiIntrLastFailureType: %2cIscsiIntrLastTgtFailureName: %3cIscsiIntrLastTgtFailureAddrType: %4cIscsiIntrLastTgtFailureAddr: %5This trap is sent when a login is failed by a initiator.The implementation of this trap should not send more than 3 notifications of this type in any 10 second time span.

28 880D001C 2 cIscsiInstSsnFailures: %1cIscsiInstLastSsnFailureType: %2cIscsiInstLastSsnRmtNodeName: %3Sent when an active session is failed by either the initiator or the target.The implementation of this trap should not send more than 3 notifications of this type in any 10 second time span.

29 880D001D 2 fcNameServerPortName: %1fcNameServerRejectReasonCode: %2fcNameServerRejReasonCodeExp: %3This notification is generated by the Name Server whenever it rejects a registration request. The Name Server should update the 'fcNameServerRejectReasonCode' and 'fcNameServerRejReasonCodeExp' objects with the corresponding reason code and reason code explanation before sending the notification. These two objects are also included along with the notification to provide the reason for the reject.

30 880D001E 2 notifyVsanIndex: %1This notification is generated by the Name Server when the Name Server cannot allocate space for a new entry.

31 880D001F 2 cRFStatusUnitId: %1sysUpTime: %2cRFStatusLastSwactReasonCode %3A SWACT notification is sent by the newly active redundant unit whenever a switch of activity occurs. In the case where a SWACT event may be indistinguishable from a reset event, a network management station should use this notification todifferentiate the activity.sysUpTime is the same sysUpTime defined in the RFC-1213 MIB.

32 880D0020 2 cRFStatusUnitId: %1cRFStatusUnitState: %2cRFStatusPeerUnitId: %3cRFStatusPeerUnitState: %4A progression notification is sent by the active redundant unit whenever its RF state changes or the RF state of the peer unit changes.To avOID a flurry of notifications for all state transitions, notifications will only be sent for transitions to the following RF states: standbyCold, standbyHot, active, activeExtraload.

Table 7: Cisco MDS Switch Event Codes

Event ID Event Code Severity Description

Page 23: c00287657

Cisco MDS switch event codes

23Event code definitions application notes

33 880D0021 2 rscnElsRejReasonCode: %1rscnNotifyFcId: %2This notification is generated by the RSCN module on this switch whenever it rejects a SCR or RSCN request.The RSCN module should update the rscnElsRejReasonCode object with the corresponding reason code before sending the notification. The rscnScrFcId object indicates the FC-ID of the sender of the request that was rejected.

34 880D0022 2 rscnIlsRejReasonCode: %1rscnNotifyFcId: %2This notification is generated by the RSCN module on this switch whenever it rejects a SW_RSCN request.The RSCN module should update the rscnIlsRejReasonCode object with the corresponding reason code before sending the notification.The rscnScrFcId object contains the FC-ID of the sender of the request that was rejected.

35 880D0023 2 ciscoScsiTgtDeviceStatus: %1A notification will be generated for each occurrence of the abnormal status (e.g., if the SCSI target device's current status is abnormal) providing that the SCSI instance's value of ciscoScsiInstNotifEnable is enabled. An SNMP agent implementing the SCSI MIB should not send more than three SCSI identical notifications in any 10-second period.

36 880D0024 2 ciscoScsiLuStatus: %1A notification will be generated each time that ciscoScsiLuStatus will change providing that the SCSI instance's value of ciscoScsiInstScsiNotificationsEnable is enabled.An SNMP agent implementing the SCSI MIB should not send more than three SCSI identical notifications in any 10-second period.

37 880D0025 2 clogHistFacility: %1clogHistSeverity: %2clogHistMsgName: %3clogHistMsgText: %4clogHistTimestamp: %5When a syslog message is generated by the device a clogMessageGenerated notification is sent. The sending of these notifications can be enabled/disabled via the clogNotificationsEnabled object.

38 880D0026 2 cseHaRestartReason: %1cseHaRestartService: %2cseHaRestartStateless: %3A service restart notification is generated whenever a service (or a process) on the 'active' supervisor is restarted.

Table 7: Cisco MDS Switch Event Codes

Event ID Event Code Severity Description

Page 24: c00287657

Cisco MDS switch event codes

24 Event code definitions application notes

39 880D0027 2 csyClockDateAndTime: %1A clock changed notification is generated when the current local date and time for the system has been manually changed. The value of csyClockDateAndTime reflects new date and time.

40 880D0028 2 virtualNwIfIndex: %1ifName: %2This notification is generated by the agent whenever an virtual interface is created in the, 'virtualNwIfTable'. Note that this notification is generated only when a new entry is added to the table and not for any modifications to an existing entry.

41 880D0029 2 virtualNwIfIndex: %1This notification is generated by the agent whenever an virtual interface is deleted from the 'virtualNwIfTable'.

42 880D002A 2 notifyVsanIndex: %1vsanAdminState: %2vsanOperState: %3A state change notification is generated whenever vsanOperState is changed. The index and both states of the VSAN after the change, are included as variables in the notification.

43 880D002B 2 wwnmType1AvailableWwns: %1A WWN shortage notification is generated whenever the number of available Type 1 WWNs 'wwnmType1AvailableWwns' reduces to either 20% or 10% or 0% of the maximum number of Type 1 WWNs 'wwnmType1MaxWwns'. After a shortage event is generated for a threshhold (say 20%), another such event will not be generated until after an availability event (see wwnmType1WwnAvailableNotify) is generated for the same threshold.

44 880D002C 2 wwnmType1AvailableWwns: %1An availability notification is generated whenever the number of available Type 1 WWNs (wwnmType1AvailableWwns) increases to either 25% or 15% or 5% of the maximum number of Type 1 WWNs (wwnmType1MaxWwns) after a wwnmType1WwnShortageNotify notification has been generated for either 20% or 10% or 5% respectively.

Table 7: Cisco MDS Switch Event Codes

Event ID Event Code Severity Description

Page 25: c00287657

Cisco MDS switch event codes

25Event code definitions application notes

45 880D002D 2 wwnmTypeOtherAvailableWwns: %1A WWN shortage notification is generated whenever the number of available Type Other WWNs 'wwnmTypeOtherAvailableWwns' reduces to either 20% or 10% or 0% of the maximum number of Type Other WWNs 'wwnmTypeOtherMaxWwns'.After a shortage event is generated for a threshhold (say 20%), another such event will not be generated until after an availability event (see wwnmType1WwnAvailableNotify) is generated for the same threshold.

46 880D002E 2 wwnmTypeOtherAvailableWwns: %1An availability notification is generated whenever the number of available Type Other WWNs (wwnmTypeOtherAvailableWwns) increases to either 25% or 15% or 5% of the maximum number of Type Other WWNs (wwnmTypeOtherMaxWwns) after a wwnmTypeOtherWwnShortageNotify notification has been generated for either 20% or 10% or 5% respectively.

47 880D002F 2 zoneMemberFormat: %1zoneMemberID: %2zoneServiceRejReasonCode: %3zoneServiceRejReasonCodeExp: %4This notification is generated whenever the local Zone Server rejects a registration request. The Zone Server should update the zoneServiceRejReasonCode and zoneServiceRejReason-CodeExp objects with the corresponding reason code and reason code explanation before sending the notification.The zoneMemberType and zoneMemberID identify the source of the request.

48 880D0030 3 zifIndex: %1zoneMergeFailureVSANNum: %2This notification is generated whenever there is a zone merge failure.If all VSANs on a link have a zone-merge failure at the same time, then just one notification is generated in which zoneMergeFailureVSANNum object has a zero value.

Table 7: Cisco MDS Switch Event Codes

Event ID Event Code Severity Description

Page 26: c00287657

Cisco MDS switch event codes

26 Event code definitions application notes

49 880D0031 2 zifIndex: %1zoneMergeSuccessVSANNum: %2This notification is generated whenever a zone merge happens successfully.If all VSANs on a link have a zone-merge success at the same time, then just one notification is generated in which zoneMergeSuccessVSANNum object has a zero value.

50 880D0032 2 zoneDefaultZoneBehaviour: %1An authenticationFailure trap signifies that the SNMPv2 entity, acting in an agent role, has received a protocol message that is not properly authenticated. While all implementations of the SNMPv2 must be capable of generating this trap, the snmpEnableAuthenTraps object indicates whether this trap will be generated.

51 880D0033 2 cIscsiTgtLoginFailures: %1cIscsiTgtLastFailureType: %2cIscsiTgtLastIntrFailureName: %3 cIscsiTgtLastIntrFailureAddrType: %4cIscsiTgtLastIntrFailureAddr: %5This trap is sent when a login is failed by a target.The implementation of this trap should not send more than 3 notifications of this type in any 10 second time span.

Table 7: Cisco MDS Switch Event Codes

Event ID Event Code Severity Description

Page 27: c00287657

HSG Element Manager event codes

27Event code definitions application notes

HSG Element Manager event codesThe HSG Element Manager is an application provided with the Storage Management Appliance that you use to configure and monitor HSG80/60 storage elements. The HSG Element Manager generates events that help users understand the status of both the manager application and the storage elements. The system records these events in the Storage Management Appliance Event Log.

Note: Using the Storage Management Appliance to monitor an active HSG80 controller in Data Replication Manager (DRM) mode is not supported. The events in Table 8 that pertain to DRM are marked with an asterisk (*). These events are not captured by the Storage Management Appliance.

Table 8: HSG Element Manager Event Codes

Event ID Event Code Severity Description6001 88011771 2 HSGSubsystem object created.6002 88011772 2 Sense Data found.6003 88011773 2 %1 state changed to online.6004 88011774 5 %1 state changed to offline.6005 88011775 2 %1 container state changed to good.6006 88011776 5 %1 container state changed to failed.6007 88011777 2 %1 container state changed to Reconstructing.6008 88011778 2 %1 container state changed to Initializing.6009 88011779 3 %1 container state changed to Reduced.6010 8801177A 2 %1 state changed to good. %2.6011 8801177B 5 %1 state changed to failed. %2.6012 8801177C 7 No controllers found.6013 8801177D 3 New controller %1 found.6014 8801177E 4 Other controller %1 unreachable.6015 8801177F 3 Other controller %1 reachable.6016 88011780 2 Controller %1 Cache Battery state changed to good.6017 88011781 3 Controller %1 Cache Battery state changed to low.6018 88011782 5 Controller %1 Cache Battery state changed to bad.6019 88011783 2 Controller %1 Cache state changed to good.6020 88011784 5 Controller %1 Cache state changed to bad.6021 88011785 5 Controller %1 Cache state changed to invalid.6022 88011786 4 Failed to refresh HSGSubsystem.6023 88011787 4 Failed to refresh Virtual Disks.6024 88011788 4 Failed to refresh Storage Sets.6025 88011789 4 Failed to refresh Devices.6026 8801178A 4 Failed to refresh Host Connections.6027 8801178B 4 Failed to rescan HSGSubsystem.

Page 28: c00287657

HSG Element Manager event codes

28 Event code definitions application notes

6028 8801178C 7 Striped Mirror set modification. Members do not match.

6029 8801178D 7 Too few mirrorset members for striped mirror set.6030 8801178E 7 Mirrorset already a member.6031 8801178F 7 STL Exception generated. %16032 88011790 7 Unknown system Exception generated. %16033 88011791 7 HSG Exception generated. %16034 88011792 7 Invalid Controller Pointer6035 88011793 7 Invalid Container Pointer. %16036 88011794 3 Device not found. %16037 88011795 3 %1 not found.6038 88011796 3 Storage Set not found.6039 88011797 3 Host Connection not found.6040 88011798 4 Test Unit Ready failed.6041 88011799 2 Virtual Disk %1 deleted.6042 8801179A 2 Virtual Disk %1 created.6043 8801179B 2 Device %1 added.6044 8801179C 2 Device %1 deleted.6045 8801179D 3 Host Connection %1 went offline.6046 8801179E 2 Host Connection %1 went online.6047 8801179F 3 Invalid parameter was found in request. %1.6048 880117A0 7 Invalid Storage Set type found. %1. 6049 880117A1 4 Attempt to create virtual disk failed. %1. 6050 880117A2 4 Attempt to modify virtual disk failed. %1. 6051 880117A3 4 Attempt to delete virtual disk failed. %1. 6052 880117A4 4 Attempt to modify device failed. %1. 6053 880117A5 4 Attempt to modify Controller failed. %1. 6054 880117A6 4 Attempt to modify Host Connection failed. %1. 6055 880117A7 4 Attempt to delete Host Connection failed. %1. 6056 880117A8 4 Attempt to rename Host Connection failed. %1. 6057 880117A9 4 Snapshot: %1 not created.6058 880117AA 2 Snapshot: %1 created.6059 880117AB 2 Virtual Disk modified. %1 6060 880117AC 2 %1 modified. 6061 880117AD 2 Controller modified. %16062 880117AE 2 Host Connection %1 modified. 6063 880117AF 2 Host connection %1 has been renamed to %2.6064 880117B0 2 Host Connection %1 deleted.

Table 8: HSG Element Manager Event Codes (Continued)

Event ID Event Code Severity Description

Page 29: c00287657

HSG Element Manager event codes

29Event code definitions application notes

6065 880117B1 4 Attempt to rescan storage failed. %1. 6066 880117B2 4 Attempt to Delete Storage Set failed. %1. 6067 880117B3 4 Attempt to Delete Device failed. %1. 6068 880117B4 2 Virtual disk: %1, %2 member removed.6069 880117B5 4 Attempt to remove a member from a Virtual Disk

failed. %1.6070 880117B6 7 Invalid Device Pointer. %1. 6071 880117B7 4 Attempt to remove Failed Set member failed. %1. 6072 880117B8 4 Attempt to add member to Spare Set failed. %1. 6073 880117B9 4 Attempt to remove member from Spare Set failed.

%1. 6074 880117BA 6 EMU state now invalid. %1. 6075 880117BB 2 EMU state now valid. %1. 6076 880117BC 6 Power supply has gone bad. %1. 6077 880117BD 2 Power supply is now good. %1. 6078 880117BE 6 Fan has gone bad. %1. 6079 880117BF 2 Fan is now good. %1. 6080 880117C0 6 High Temperature detected. %1. 6081 880117C1 2 Temperature is within optimal range. %1. 6082 880117C2 6 Airflow is bad. %1. 6083 880117C3 2 Airflow is now good. %1. 6084 880117C4 2 EMU is present. 6085 880117C5 6 EMU is no longer present. 6086 880117C6 7 Cabinet %1 went offline. 6087 880117C7 2 Cabinet %1 went online. 6088 880117C8 6 Master cabinet has no controller installed. %1.6089 880117C9 2 Master cabinet has controller installed. %1. 6090 880117CA 2 Controller present but present in slave cabinet. %1.6091 880117CB 2 Master cabinet has controller installed. %1.6092 880117CC 6 UPS has gone bad. %1. 6093 880117CD 2 UPS is now good. %1. 6094 880117CE 6 Shelf is bad. %1.6095 880117CF 2 Shelf is good. %1.6096 880117D0 6 Voltage has gone bad. %1.6097 880117D1 2 Voltage is now good. %1.6098 880117D2 3 Other controller failed.6099 880117D3 2 Other controller now good.6100 880117D4 6 Communication with subsystem has gone down. %.6101 880117D5 2 Regained communication to subsystem.

Table 8: HSG Element Manager Event Codes (Continued)

Event ID Event Code Severity Description

Page 30: c00287657

HSG Element Manager event codes

30 Event code definitions application notes

*6102 880117D6 4 Attempt to create Remote Copy Set failed. %1.*6103 880117D7 2 Remote copy set: %1 created. *6104 880117D8 4 Attempt to Delete Remote Copy Set failed. %1.6105 880117D9 2 RCS: %1 deleted.*6106 880117DA 4 Attempt to modify Remote Copy Set failed. %1.6107 880117DB 2 %1 RCS has been modified.6108 880117DC 3 No Modifications were made. %1.*6109 880117DD 3 Attempt to set failsafe on Remote Copy Set failed. %1.*6110 880117DE 4 Attempt to Delete Association failed. %1.*6111 880117DF 4 Attempt to create Association failed. %1.6112 880117E0 2 Association: %1 created.6113 880117E1 2 Association: %1 not deleted. *6114 880117E2 4 Attempt to modify Association failed. %1.*6115 880117E3 2 %1 Association has been modified.6116 880117E4 2 Name is in use.6117 880117E5 4 %1 unable to add to spare set.6118 880117E6 2 Item is already used.6119 880117E7 2 Device %1 added to Spare Set.6120 880117E8 2 Device %1 removed from Spare Set.6121 880117E9 2 Device removed from Failed Set.6122 880117EA 4 Attempt to expand Virtual Disk failed. %16123 880117EB 2 Virtual Disk expanded.6124 880117EC 2 %1 Virtual Disk not expandable.6125 880117ED 4 Incomplete Concatset modify: %1.6126 880117EE 2 Storage Set modified. 6127 880117EF 4 Attempt to modify Chunksize failed.6128 880117F0 7 HSGSubsystem Assertion.6129 880117F1 4 Codeload failed. %1.6130 880117F2 3 Codeload Error. %1.6131 880117F3 2 Top Controller is rebooting.6132 880117F4 2 Bottom Controller is rebooting.6133 880117F5 2 Both Controllers are rebooting.6134 880117F6 4 Could not locate top controller.6135 880117F7 4 Could not locate bottom controller.6136 880117F8 2 Operating state is normal. %1.6137 880117F9 6 Operating state is failed. %1.6138 880117FA 4 Operating state is impaired. %1.6139 880117FB 2 Top controller is done rebooting.

Table 8: HSG Element Manager Event Codes (Continued)

Event ID Event Code Severity Description

Page 31: c00287657

HSG Element Manager event codes

31Event code definitions application notes

6140 880117FC 2 Bottom controller is done rebooting.6141 880117FD 2 Both controllers are done rebooting.6142 880117FE 4 Reboot of controller failed. %1.6143 880117FF 2 SCSI command did not complete. %1.6144 88011800 2 EMU modified. 6145 88011801 4 EMU modify failed. *6146 88011802 2 Unit is an Association Log Device.6147 88011803 2 Unit is an RCS Initiator.6148 88011804 2 Unit has been expanded.6149 88011805 2 Unit has no preferred path.6150 88011806 2 Unit is transportable.6151 88011807 2 Unit is a Snapshot.6152 88011808 2 Unit writeback cache is disabled.6153 88011809 2 Unit storage container is partitioned.6154 8801180A 2 Incompatible storage container type.6155 8801180B 2 No peer to peer configuration.6156 8801180C 2 Unit is in Failed state.6157 8801180D 2 Unit has too few devices.6158 8801180E 2 Unit not in correct state.6159 8801180F 2 Unit is used by another configuration.6160 88011810 2 Unit is a Snapshot source.6161 88011811 2 Subsystem firmware does not support snapshots.6162 88011812 2 Subsystem does not have peer to peer support

enabled.6163 88011813 2 HSGSubsystem Miscellaneous info. 6164 88011814 2 Mirror cache is not enabled.6165 88011815 2 Controller cache size is too small.6166 88011816 3 HSGSubsystem Unknown Status. 6167 88011817 3 Subsystem has the maximum number of snapshots. 6168 88011818 4 Not enough available physical disks or unused

stripes. 6169 88011819 3 Reached maximum physical disk count. 6170 8801181A 4 Virtual Disk is a target. 6171 8801181B 2 Initialize container failed. %1. 6172 8801181C 2 Initialized container successfully. %1. 6173 8801181D 4 No available containers. 6174 8801181E 2 Reservation mutex check failed. 6175 8801181F 7 Container not found. %1. 6176 88011820 2 %1 Used by name list.

Table 8: HSG Element Manager Event Codes (Continued)

Event ID Event Code Severity Description

Page 32: c00287657

HSG Element Manager event codes

32 Event code definitions application notes

*6177 88011821 2 Unable to disable the PPRCMode.6178 88011822 4 Add VD member failed. %1.6179 88011823 2 Virtual Disk: %1, added member %2 successfully.6180 88011824 2 Check VirtualDisk not in REDUCE state or

Replacement policy not NONE or not available physical disks.

6181 88011825 2 Rejected because of reservation. %1. 6182 88011826 4 Need ACS firmware revision 8.7 for management

lockdown.6183 88011827 2 Virtual disk %1 has been reserved by %2. 6184 88011828 2 A virtual disk has been unreserved. %1.6185 88011829 2 Virtual disk reservation failure. %1. 6186 8801182A 2 Management lock down change. %1. 6187 8801182B 2 No available disks. 6188 8801182C 2 Maximum number of members. 6189 8801182D 2 Replacement policy must be NOPOLICY. 6190 8801182E 2 Raidset must be in reduced state. 6191 8801182F 2 Code patch %1-%2 is Successfully loaded on %3

controller.7001 88011B59 6 HSGSubsystem API has lost comm to Subsystem. %1.7002 88011B5A 4 HSGSubsystem API has returned controller error text.

%1.7003 88011B5B 4 HSGSubsystem API has received Invalid show this

output.7004 88011B5C 4 HSGAPI::getAllControllers: Invalid SHOW OTHER

output.7005 88011B5D 4 Invalid SHOW UNIT output %1.7006 88011B5E 4 HSGSubsystem API has received Invalid show storage

output. %1.7007 88011B5F 4 Invalid SHOW DEV FULL output.7008 88011B60 4 HSGSubsystem API has received Invalid show

connection output. %1.7009 88011B61 3 HSGSubsystem API received modification request but

no changes were found. %1.7010 88011B62 3 HSGSubsystem API received delete request but no

changes were found. %1.7011 88011B63 3 HSGSubsystem API invalid CLI syntax or incomplete

CLI command error (Last Status). %1.7012 88011B64 2 HSGSubsystem API has returned controller warning

text.7013 88011B65 2 HSGSubsystem API This controller rebooting.7014 88011B66 2 HSGSubsystem API Other controller rebooting.7015 88011B67 2 HSGSubsystem API Both controllers rebooting.

Table 8: HSG Element Manager Event Codes (Continued)

Event ID Event Code Severity Description

Page 33: c00287657

HSG Element Manager event codes

33Event code definitions application notes

7016 88011B68 4 HSGAPI::getAllAssociations: Invalid SHOW AllAssociations output %1.

*7017 88011B69 4 HSGSubsystem API has received Invalid show Remote Copy. %1.

7018 88011B6A 4 HSGSubsystem API Setting Host connection failure.7019 88011B6B 4 HSGAPI::getAutospare, Invalid SHOW FAILEDSET

output.7020 88011B6C 3 Comm path switched. %1.7021 88011B6D 3 Unable to switch comm path. %1.7022 88011B6E 3 Last Status.8204 8801200C 7 A spurious interrupt was detected during the

execution of a Subsystem Built-In Self Test.8205 8801200D 7 An unrecoverable error was detected during

execution of the HOST PORT Subsystem Test. The system will not be able to communicate with the host.

8206 8801200E 7 An unrecoverable error was detected during execution of the UART/DUART Subsystem Test. This will cause the console to be unusable. This will cause failover communications to fail.

8207 8801200F 7 An unrecoverable error was detected during execution of the FX Subsystem Test.

8301 8801206D 7 An unrecoverable error was detected during execution of the PCI9060ES Test.

8302 8801206E 7 An unrecoverable error was detected during execution of the Device Port Subsystem Built-In Self Test. One or more of the device ports on the controller module has failed; some/all of the attached storage is no longer accessible via this controller.

8303 8801206F 7 Deletion of component failed.8304 88012070 2 A component location has been updated.8305 88012071 2 A component name has been updated.8306 88012072 6 HSG not communicating.8307 88012073 2 HSG is communicating.8308 88012074 3 Log approaching max size, prior entries removed.8309 88012075 2 New HSG found.

Table 8: HSG Element Manager Event Codes (Continued)

Event ID Event Code Severity Description

Page 34: c00287657

Command View EVA event codes

34 Event code definitions application notes

Command View EVA event codesCommand View EVA is an application provided with the Storage Management Appliance that you use to configure and monitor HSV110 Array Controllers. Command View EVA generates controller events and management agent events that help users understand the status of both the manager application and the storage elements.

The Storage Management Appliance supports HSV MIB versions 2.0a, 2.1, and 3.0.

Controller eventsTable 9 describes the events generated by the HSV Controller. These events are logged in the Storage Management Appliance Event Log. You can use the Software Component ID (SWC ID) and Event Number (Evt. No.) codes to correlate events recorded in the HSV Controller Event Log of Command View EVA with events recorded in the Storage Management Appliance Event Log.

Table 9: Command View EVA Event Codes: Controller Events

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

100 88030064 3 0 0 Storage Cell: %1 Event ID: %2 Description: Unrecognized Controller event generated.

256 88030100 2 1 0 Storage Cell: %1 Event ID: %2 Description: During Executive Services initialization the system time value was set to the value contained in the time field. The action field contains one of the following codes which describes the condition that caused the time value to be chosen: 0 = TOY clock unavailable; time reset to default date and time. 1 = TOY clock time value was less than or equal to the last known time value previously stored in nonvolatile memory; time reset to default date and time. 2 = EDC was bad for last known time value previously stored in nonvolatile memory; time reset to default date and time. 3 = TOY clock not running; time reset to default date and time. 4 = TOY clock time value believed to be accurate; time set to TOY clock time value.

257 88030101 2 1 1 Storage Cell: %1 Event ID: %2 Description: The system time value was set to the value contained in the time field by a call to the EXEC$SET_TIME service. As part of setting the time in a dual HSV controller configuration, the times are synchronized. The action field contains one of the following codes which describes the action taken: 0 = The time was set to the time value on this HSV controller. 1 = The master HSV controller requested the slave HSV controller to set it’s time to the time value. 2 = The slave HSV controller set the local time to the time value. 3 = The HSV controller’s TOY clock was set to the time value.

768 88030300 2 3 0 Storage Cell: %1 Event ID: %2 Description: The HSV controller identified in the node_name field has failed in communicating with the Cabinet (Rack) Bus Interface Controller.

Page 35: c00287657

Command View EVA event codes

35Event code definitions application notes

769 88030301 6 3 1 Storage Cell: %1 Event ID: %2 Description: The physical disk drive identified by the device field has been rendered inoperable. If the flags.quorum_disk flag is nonzero, the physical disk drive is the Storage System Quorum disk identified in the quorum_sequence field. If the flags.inq_state flag is nonzero, the content of the inq_data and capacity fields is valid. If the rss_flags.member_abnormal flag is nonzero, the content of the member_state field is valid. The rack_num field will not be valid until a future release. The reason_code field contains a code giving the reason the physical disk drive has been rendered inoperable: 0x001 = CS IO failure 0x002 = Scrubber IO failure 0x003 = Attempt to set CBIT on normal drive 0x004 = Attempt to set CBIT on merging drive 0x100 = The Target Discovery Service Descriptor retry count has been exceeded 0x101 = Inoperable for Bad Block Replacement 0x102 = The soft error count has been exceeded 0x103 = The number of exchange timeouts permitted was exceeded 0x104 = Communication with drive has failed an excessive number of times 0x105 = The number of retries has been exceeded 0x106 = Medium/Hardware Errors encountered on this physical disk drive 0x107 = The number of Directed LIP’s has surpassed the threshold 0x200 = Smart event from a physical disk drive not in Storage System 0x201 = Smart event from a physical disk drive not a Volume 0x202 = Smart event from a physical disk drive not a RSS 0x203 = Failure predicted from physical disk drive 0x204 = Can’t read from physical disk drive from the poll 0x205 = Failure predicted from physical disk drive while deleting Disk Group 0x206 = physical disk drive forced inoperative from maintenance command for temporary POID 0x207 = physical disk drive forced inoperative from maintenance command for POID 0x208 = Bad block recovery failed or can’t read FPAB 0x209 = Failure to remove volume from Storage System 0x20A = Failure to update metadata.

770 88030302 3 3 2 Storage Cell: %1 Event ID: %2 Description: The physical disk drive identified in the node_name field will not be used because the maximum number of physical disk drives already exist in the current Storage System.

771 88030303 2 3 3 Storage Cell: %1 Event ID: %2 Description: A HSV controller has begun booting. That controller is identified in the node_name field. Note that in this case the content of the scell_tag field is undefined.

772 88030304 2 3 4 Storage Cell: %1 Event ID: %2 Description: The HSV controller identified in the node_name field has finished the process of bringing the Storage System, identified in the scell_tag field, online.

773 88030305 2 3 5 Storage Cell: %1 Event ID: %2 Description: The HSV controller identified in the node_name field has been joined into the Storage System.

774 88030306 2 3 6 Storage Cell: %1 Event ID: %2 Description: The HSV controller identified in the node_name field has been ousted from the Storage System identified in the scell_tag field.

775 88030307 2 3 7 Storage Cell: %1 Event ID: %2 Description: The HSV controller identified in the node_name field is now the Storage System, identified in the scell_tag field, master.

776 88030308 2 3 8 Storage Cell: %1 Event ID: %2 Description: The HSV controller identified in the node_name field has been brought into the Storage System identified in the scell_tag field.

1024 88030400 6 4 0 Storage Cell: %1 Event ID: %2 Description: HSV controller operation was terminated due to an unrecoverable event detected by either software or hardware or due to an action initiated via the Storage System Management Interface.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 36: c00287657

Command View EVA event codes

36 Event code definitions application notes

1025 88030401 6 4 1 Storage Cell: %1 Event ID: %2 Description: An HSV controller has sent a last gasp message prior to terminating operation. The terminated HSV controller is identified in the lter.terminating_ctrlr field. The lter.termination_event.u.value field contains the termination cause (i.e., termination code). The lter.termination_event.termination_location field contains the termination location. The lter.termination_time field contains the termination date and time. The lter.seq field contains the index of the HSV controller’s Last Termination Event Array element assigned to the termination event. The lter.sw_version, lter.baselevel_id, and lter.ctrlr_model_id fields identify the software level and controller model information. The lter.uptime field contains a value that represents the number of seconds the HSV controller has executed functional code since its first power up. Note that the reporting_ctrlr header field identifies the HSV controller that received the last gasp message. All other header fields reflect information supplied by the terminating controller.

1026 88030402 6 4 2 Storage Cell: %1 Event ID: %2 Description: A machine check occurred while a termination event was being processed. The post-termination operation being performed at the time the event occurred can be derived from the lter.reuea_index field. Note: The lteihd and lter fields may not describe the event that caused the HSV controller to terminate operation depending on how far termination processing got before the machine check occurred.

1027 88030403 6 4 3 Storage Cell: %1 Event ID: %2 Description: An unexpected event occurred while a termination event was being processed. The value contained in the uei.type field describes the event as follows: 0 = Unrecognized Unexpected Event code. 1 = Power failure before initialization could complete. 2 = Recursive termination before initialization could complete. 3 = Terminated during the first part post-termination preparation. 4 = Terminated during the load of the G3 Glue registers. 5 = Terminated during the second part post-termination preparation. 6 = Terminated during event report block load. 7 = Terminated during initialization of all hardware components and software data structures in preparation for restart. 8 = Terminated during execution of an unrecognized post-termination operation (premature). 9 = Power failure during execution of a post-termination operation. A = No good entries found in Termination Event Array. (Note that this condition is expected following the first boot of a newly manufactured HSV controller. In that case this event can be safely ignored; no action is necessary.) B = The EDC of one or more Termination Event Array entries is bad. C = Termination Event Array entry control block revision is different. D = Termination Event Array entry information block revision is different. E = Termination Event Array entry up time value is greater than the system’s up time value. F = Termination Event Array entry up time value is less than the previous entry’s up time value. 10= Termination Event Array entry sequence number value is less than the previous entry’s sequence number value. 11= Detected an unrecognized dump/restart control code. 12= Failed to terminate the entity dump loop. 13= Unexpected dump entity size. 14= Unexpected Event Log Packet processing stage code. 15= Number of Termination Parameters supplied not equal to maximum allowed as required. The post-termination operation being performed at the time the unexpected event occurred is contained in the uei.pto field. Note: The lteihd and lter fields may not describe the event that caused the HSV controller to terminate operation depending on how far termination processing got before the unexpected event occurred.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 37: c00287657

Command View EVA event codes

37Event code definitions application notes

1028 88030404 2 4 4 Storage Cell: %1 Event ID: %2 Description: The Storage System Event Log validation completed successfully. The content of the cinfo.scelcbi.status field, the cinfo.scelcbi structure, and the minfo.scelmi structure show the validated state of the Storage System Event Log. The meaning of the status value contained in the cinfo.scelcbi.status field is as follows: 0 = No problems found. Note: The content of the ainfo fields, cinfo.sctelcbi structure, and minfo.sctelmi structure is undefined.

1029 88030405 2 4 5 Storage Cell: %1 Event ID: %2 Description: The Storage System Event Log validation failed. The content of the cinfo.scelcbi.status field, the cinfo.scelcbi structure, and the minfo.scelmi structure show the state of the Storage System Event Log at the time of the failure. The content and state of the Storage System Event Log have been initialized to their initial operational settings. The meaning of the status value contained in the cinfo.scelcbi.status field is as follows: 1 = Cookie value is not as expected. 2 = Event data overflows the buffer. 3 = Event data size is not a multiple of 4 bytes, is less than the minimum, or is greater than the maximum. 4 = Event Information Packet type is greater than the maximum. 5 = Event information size is not a multiple of 4 bytes, is less than the minimum, is greater than the maximum, doesn’t match the Event Information Packet type size, or when combined with the entry header size doesn’t equal the entry size. 6 = Event code is zero. 7 = Event is out of sequence. 8 = Dead space area at the end of a partially packed buffer contains a nonzero value. 9 = An event data block containing a nonzero value was found after end of event data was detected. A = Sequence number reset flag not set as expected. B = The event log contains no entries. C = Event data block read failed during maintenance verification. D = Event data block read failed during maintenance completion. E = Event data block erase failed during maintenance completion. F = Control block read failed during maintenance verification. 17= The event log was destroyed and prepared for re-initialization. Note: The content of the ainfo fields, cinfo.sctelcbi structure, and minfo.sctelmi structure is undefined.

1030 88030406 6 4 6 Storage Cell: %1 Event ID: %2 Description: Event reports were lost due to an insufficient supply of Event Log Packets on the HSV controller that is the Storage System Master. The ainfo.events_not_reported field shows the number of event reports lost.Note: The content of the ainfo.quiesce_type field, ainfo.remote_event field cinfo.sctelcbi structure, and minfo.sctelmi structure is undefined.

1031 88030407 6 4 7 Storage Cell: %1 Event ID: %2 Description: Event reports were lost due to an insufficient supply of Event Log Packets on the HSV controller that is not the Storage System Master. The ainfo.events_not_reported field shows the number of event reports lost. Note: The content of the ainfo.quiesce_type field, ainfo.remote_event field cinfo.sctelcbi structure, and minfo.sctelmi structure is undefined.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 38: c00287657

Command View EVA event codes

38 Event code definitions application notes

1032 88030408 2 4 8 Storage Cell: %1 Event ID: %2 Description: The Storage System Termination Event Log has become inaccessible. The content of the cinfo.sctelcbi.status field, the cinfo.sctelcbi structure, and the minfo.sctelmi structure show the current state of the Storage System Termination Event Log. The meaning of the status value contained in the cinfo.sctelcbi.status field is as follows: F = Control block read failed during maintenance verification. 10= Control block write failed during maintenance verification. 11= Event data block write failed during maintenance update. 12= Control block write failed during maintenance completion. 13= Storage System Termination Event Log related send was unsuccessful or the master found that the Storage System Termination Event Log is inaccessible. 16= Event data block read failed during retrieval request. Note: The content of the ainfo fields, cinfo.scelcbi structure, and minfo.scelmi structure is undefined.

1033 88030409 2 4 9 Storage Cell: %1 Event ID: %2 Description: The Storage System Termination Event Log validation completed successfully. The content of the cinfo.sctelcbi.status field, the cinfo.sctelcbi structure, and the minfo.sctelmi structure show the validated state of the Storage System Termination Event Log. The meaning of the status value contained in the cinfo.sctelcbi.status field is as follows: 0 = No problems found. Note: The content of the ainfo fields, cinfo.scelcbi structure, and minfo.scelmi structure is undefined.

1034 8803040a 2 4 a Storage Cell: %1 Event ID: %2 Description: The Storage System Termination Event Log validation failed. The content of the cinfo.sctelcbi.status field, the cinfo.sctelcbi structure, and the minfo.sctelmi structure show the state of the Storage System Termination Event Log at the time of the failure. The meaning of the status value contained in the cinfo.sctelcbi.status field is as follows: F = Control block read failed during maintenance verification. 10= Control block write failed during maintenance verification. 11= Event data block write failed during maintenance update. 12= Control block write failed during maintenance completion. 13= Storage System Termination Event Log related send was unsuccessful or the master found that the Storage System Termination Event Log is inaccessible. 16= Event data block read failed during retrieval request. 17= The log was destroyed and prepared for re-initialization. Note: The content of the ainfo fields, cinfo.scelcbi structure, and minfo.scelmi structure is undefined.

1035 8803040b 2 4 b Storage Cell: %1 Event ID: %2 Description: The Storage System Termination Event Log has been updated with the termination event information obtained from the HSV controller that is not the Storage System Master. The content of the cinfo.sctelcbi.status field, the cinfo.sctelcbi structure, and the minfo.sctelmi structure show the updated state of the Storage System Termination Event Log. The meaning of the status value contained in the cinfo.sctelcbi.status field is as follows: 0 = No problems found. Note: The content of the ainfo fields, cinfo.scelcbi structure, and minfo.scelmi structure is undefined.

1036 8803040c 6 4 c Storage Cell: %1 Event ID: %2 Description: The Fault Manager on the Storage System Master received an invalid Event Information Packet from the remote Fault Manager. The header information from the invalid Event Information Packet is contained in the ainfo.remote_event field. Note: The content of the ainfo.quiesce_type field, ainfo.events_not_reported field, cinfo.scelcbi structure, cinfo.sctelcbi structure, minfo.scelmi structure, and minfo.sctelmi structure is undefined.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 39: c00287657

Command View EVA event codes

39Event code definitions application notes

1037 8803040d 2 4 d Storage Cell: %1 Event ID: %2 Description: The Fault Manager operation was made quiescent. If the ainfo.quiesce_type field is equal to 0, the operation was performed on both HSV controllers. If the ainfo.quiesce_type field is equal to 1, the operation was performed only on the HSV controller that is not the Storage System Master. Note: The content of the ainfo.events_not_reported field, cinfo.scelcbi structure, cinfo.sctelcbi structure, minfo.scelmi structure, and minfo.sctelmi structure is undefined.

1038 8803040e 6 4 e Storage Cell: %1 Event ID: %2 Description: An HSV controller sent a last gasp message prior to terminating operation with an indication that the HSV controller identified in the lter.terminating_ctrlr field should also terminate operation.

1039 8803040f 2 4 f Storage Cell: %1 Event ID: %2 Description: This HSV controller sent its termination event information to the HSV controller that is the Storage System Master. The content of the cinfo.sctelcbi.status field, the cinfo.sctelcbi structure, and the minfo.sctelmi structure show the updated state of the Storage System Termination Event Log. The meaning of the status value contained in the cinfo.sctelcbi.status field is as follows: 0 = No problems found. Note: The content of the ainfo fields, cinfo.scelcbi structure, and minfo.scelmi structure is undefined.

1040 88030410 6 4 10 Storage Cell: %1 Event ID: %2 Description: Event reports were lost due to an insufficient supply of ISR Event Log Packets on the HSV controller that is the Storage System Master. The ainfo.events_not_reported field shows the number of event reports lost. Note: The content of the ainfo.quiesce_type field, ainfo.remote_event field cinfo.sctelcbi structure, and minfo.sctelmi structure is undefined.

1041 88030411 6 4 11 Storage Cell: %1 Event ID: %2 Description: Event reports were lost due to an insufficient supply of ISR Event Log Packets on the HSV controller that is not the Storage System Master. The ainfo.events_not_reported field shows the number of event reports lost. Note: The content of the ainfo.quiesce_type field, ainfo.remote_event field cinfo.sctelcbi structure, and minfo.sctelmi structure is undefined.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 40: c00287657

Command View EVA event codes

40 Event code definitions application notes

1536 88030600 6 6 0 Storage Cell: %1 Event ID: %2 Description: A physical disk drive has reported that it has exceeded its failure prediction threshold. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The location of the physical disk drive is determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The command issued to the physical disk drive is contained in the cmd field. The sense data obtained from the physical disk drive as a result of the failure prediction threshold exceeded error is contained in the error field. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

1537 88030601 3 6 1 Storage Cell: %1 Event ID: %2 Description: A Fibre Channel port on the HSV controller has failed to respond. The identity of the affected Fibre Channel port is contained in the cerp_id field. The HSV controller internal Fibre Channel port number of the affected Fibre Channel port is contained in the port field. The peb array contains the port event block information. The peq_frz_prod_index field contains the index to the port event block in use when the Tachyon chip entered the frozen state. The peq_prod_index field contains the index to the next port event block. The peq_cons_index field contains the index to the next port event block to be acted upon. The failure_cause field contains the internal routing value as follows: 1 - Excessive exchange timeouts on loop 2 - Excessive link errors on loop 3 - Exhausted Link Down retries on loop with signal 4 - Exhausted Link Down retries on loop with loss of signal 5 - Excessive link inits on loop without completing device discovery.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 41: c00287657

Command View EVA event codes

41Event code definitions application notes

1538 88030602 2 6 2 Storage Cell: %1 Event ID: %2 Description: A physical disk drive has reported a check condition error. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The location of the physical disk drive is determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The command issued to the physical disk drive is contained in the cmd field. The sense data obtained from the physical disk drive as a result of the check condition error is contained in the error field. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 42: c00287657

Command View EVA event codes

42 Event code definitions application notes

1539 88030603 3 6 3 Storage Cell: %1 Event ID: %2 Description: An exchange sent to a physical disk drive or another HSV controller via the mirror port or a Fibre Channel port has timed out. The identity of the intended recipient is contained in the device field. The Fibre Channel port over which the frame was sent is identified in the cerp_id field. The HSV controller internal Fibre Channel port number over which the frame was sent is contained in the port field. The arbitrated loop physical address of the intended recipient is contained in the al_pa field. The missing_port and missing_cerp_id fields are unused. The location of the intended recipient is determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. Note that the content of the rack_num field will not be valid until a future release. The number of timeouts detected is contained in the num_times field. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 43: c00287657

Command View EVA event codes

43Event code definitions application notes

1540 88030604 3 6 4 Storage Cell: %1 Event ID: %2 Description: Work was unexpectedly sent to this HSV controller by a physical disk drive or another HSV controller. This HSV controller did not originate the work. The identity of the sender is contained in the device field. The Fibre Channel port over which the unexpected work was received is identified in the cerp_id field. The HSV controller internal Fibre Channel port number over which the unexpected work was received is contained in the port field. The arbitrated loop physical address of the sender is contained in the al_pa field. The location of the sender is determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. Note that the content of the rack_num field will not be valid until a future release. The hdr_cdb field contains the command descriptor block and Fibre Channel header information associated with the unexpected work.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 44: c00287657

Command View EVA event codes

44 Event code definitions application notes

1541 88030605 3 6 5 Storage Cell: %1 Event ID: %2 Description: Work has been sent to a physical disk drive or another HSV controller via the mirror port but it did not respond. The identity of the intended target is contained in the device field. The Fibre Channel port over which the work was sent is identified in the cerp_id field. The HSV controller internal Fibre Channel port over which the work was sent is contained in the port field. The arbitrated loop physical address of the intended target is contained in the al_pa field. The location of the intended target is determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The command issued to the intended target is contained in the cmd field. Note that in this case the content of the error field is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 45: c00287657

Command View EVA event codes

45Event code definitions application notes

1543 88030607 3 6 7 Storage Cell: %1 Event ID: %2 Description: A Target Discovery Service Descriptor exchange sent to a physical disk drive has timed out. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The location of the physical disk drive is determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The command issued to the physical disk drive is contained in the cmd field. Note that in this case the content of the error field is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

1544 88030608 2 6 8 Storage Cell: %1 Event ID: %2 Description: An excessive number of link errors were detected on a HSV controller’s Fibre Channel port. The identity of the affected Fibre Channel port is contained in the cerp_id field. The HSV controller internal Fibre Channel port number of the affected Fibre Channel port is contained in the port field. This is an informational event triggered by the occurrence of an excessive number of Tachyon chip link status errors detected within a particular link status error type. The number of occurrences of each link status error type is contained in a separate type-specific field (e.g., loss_of_signal, bad_rx_char, etc.). The HSV controller checks each of its Fibre Channel port’s for excessive link status errors periodically.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 46: c00287657

Command View EVA event codes

46 Event code definitions application notes

1545 88030609 6 6 9 Storage Cell: %1 Event ID: %2 Description: A physical disk drive has reported numerous failure prediction threshold exceeded errors. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The missing_port and missing_cerp_id fields are unused. The location of the physical disk drive is determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The num_times field is the number of failure prediction threshold exceeded errors reported by the physical disk drive in the previous minute. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 47: c00287657

Command View EVA event codes

47Event code definitions application notes

1546 8803060a 2 6 a Storage Cell: %1 Event ID: %2 Description: A physical disk drive has reported numerous check condition errors. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The missing_port and missing_cerp_id fields are unused. The location of the physical disk drive is determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The num_times field is the number of check condition errors reported by the physical disk drive in the previous minute. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 48: c00287657

Command View EVA event codes

48 Event code definitions application notes

1547 8803060b 3 6 b Storage Cell: %1 Event ID: %2 Description: A non-data exchange sent to a physical disk drive has timed out. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The location of the physical disk drive is determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The command issued to the physical disk drive is contained in the cmd field. Note that in this case the content of the error field is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 49: c00287657

Command View EVA event codes

49Event code definitions application notes

1548 8803060c 2 6 c Storage Cell: %1 Event ID: %2 Description: A loop switch has been detected on a Fibre Channel port. The identity of the Fibre Channel port is contained in the cerp_id field. The HSV controller internal Fibre Channel port number is contained in the port field. Note that in this case the content of the device, al_pa, rack_num, dencl_num, bay, fed_class and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The missing_port and missing_cerp_id fields are unused. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

1549 8803060d 2 6 d Storage Cell: %1 Event ID: %2 Description: The location of a physical disk drive previously reported as unknown is now known. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The missing_port and missing_cerp_id fields are unused. The location of the physical disk drive is contained in the rack_num, dencl_num, and bay fields. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of fed_class, al_pa and num_times fields are undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 50: c00287657

Command View EVA event codes

50 Event code definitions application notes

1550 8803060e 6 6 e Storage Cell: %1 Event ID: %2 Description: A Drive Enclosure Environmental Monitoring Unit requested a code update but the code update could not be found, so the update was not performed. The identity of the affected Drive Enclosure Environmental Monitoring Unit is contained in the device field. The Fibre Channel port used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the cerp_id field. The HSV controller internal Fibre Channel port number used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the port field. The missing_port and missing_cerp_id fields are unused. The location of the Drive Enclosure Environmental Monitoring Unit is contained in the rack_num and dencl_num fields. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the al_pa, bay, fed_class and num_times field is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

1551 8803060f 6 6 f Storage Cell: %1 Event ID: %2 Description: The Drive Enclosure Environmental Monitoring Unit is able to communicate with a physical disk drive but this HSV controller is unable to communicate with that physical disk drive on the Fibre Channel bus. The identity of the Drive Enclosure Environmental Monitoring Unit is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The missing_port and missing_cerp_id fields are unused. The location of the physical disk drive is contained in the rack_num, dencl_num, and bay fields. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the al_pa, fed_class and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 51: c00287657

Command View EVA event codes

51Event code definitions application notes

1552 88030610 6 6 10 Storage Cell: %1 Event ID: %2 Description: A Drive Enclosure Environmental Monitoring Unit is unable to communicate with this HSV controller. The Drive Enclosure Environmental Monitoring Unit identified in the device field has stopped communicating with the HSV controller. The Fibre Channel port used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the cerp_id field. The HSV controller internal Fibre Channel port number used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the port field. The missing_port and missing_cerp_id fields are unused. The location of the Drive Enclosure Environmental Monitoring Unit is contained in the rack_num and dencl_num fields. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the bay, al_pa, fed_class and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

1554 88030612 2 6 12 Storage Cell: %1 Event ID: %2 Description: The retry count for a task assigned to a Drive Enclosure Environmental Monitoring Unit has been exhausted. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The peb array contains the task list that was intended to be sent to the Drive Enclosure Environmental Monitoring Unit. The peq_frz_prod_index field contains the task that was being retried. The peq_prod_index field contains the drive enclosure where the physical disk drive used to communicate with the Drive Enclosure Environmental Monitoring Unit is located. The peq_cons_index field identifies the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) used to communicate with the physical disk drive that was used to communicate with the Drive Enclosure Environmental Monitoring Unit. The failure_cause field contains the bay where the physical disk drive used to communicate with the Drive Enclosure Environmental Monitoring Unit.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 52: c00287657

Command View EVA event codes

52 Event code definitions application notes

1555 88030613 2 6 13 Storage Cell: %1 Event ID: %2 Description: A Drive Enclosure Environmental Monitoring Unit is able to communicate with this HSV controller. The identity of the Drive Enclosure Environmental Monitoring Unit is contained in the device field. The Fibre Channel port used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the cerp_id field. The HSV controller internal Fibre Channel port number used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the port field. The missing_port and missing_cerp_id fields are unused. The location of the Drive Enclosure Environmental Monitoring Unit is contained in the rack_num and dencl_num fields. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the bay, fed_class and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

1556 88030614 6 6 14 Storage Cell: %1 Event ID: %2 Description: There are too many drive enclosures attached to a Fibre Channel port. The Fibre Channel port with too many drive enclosures attached to the HSV controller is contained in the cerp_id field. Note that in this case the content of the bay, fed_class, rack_num, dencl_num and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The missing_port and missing_cerp_id fields are unused. The location of the physical disk drive is determined by the content of the dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 53: c00287657

Command View EVA event codes

53Event code definitions application notes

1557 88030615 6 6 15 Storage Cell: %1 Event ID: %2 Description: The cable connected to the I/O module is attached to the wrong Fibre Channel port. The Fibre Channel port incorrectly attached to the HSV controller is contained in the cerp_id field. Note that in this case the content of the missing_port, missing_cerp_id, bay, fed_class, rack_num, dencl_num and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

1558 88030616 6 6 16 Storage Cell: %1 Event ID: %2 Description: A HSV controller does not have an address on the enclosure address bus. The HSV controller location cannot be identified. Note that in this case the content of the missing_port, missing_cerp_id, bay, fed_class, rack_num, dencl_num, al_pa, device, cerp_id, port, enclosures array and num_times fields is undefined.

1559 88030617 6 6 17 Storage Cell: %1 Event ID: %2 Description: A Drive Enclosure Environmental Monitoring Unit has detected a physical disk drive that was preventing proper loop operation. The physical disk drive has been bypassed and is ready for replacement. The location of this physical disk drive is specified by the rack_num, bay, and dencl_num fields. The rack_num field will not be valid until a future release. The identity of the Drive Enclosure Environmental Monitoring Unit is contained in the device field. The UUID of the specific physical disk drive is not identifiable. Check the fault lights of the enclosure associated with this Drive Enclosure Environmental Monitoring Unit. Note that in this case the content of the fed_class, alpa, and num_times fields are undefined.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 54: c00287657

Command View EVA event codes

54 Event code definitions application notes

1560 88030618 2 6 18 Storage Cell: %1 Event ID: %2 Description: A Drive Enclosure Environmental Monitoring Unit has begun updating its code. Do not power down this drive enclosure until the code update has completed. The identity of the Drive Enclosure Environmental Monitoring Unit is contained in the device field. The Fibre Channel port used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the cerp_id field. The HSV controller internal Fibre Channel port number used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the port field. The missing_port and missing_cerp_id fields are unused. The location of the Drive Enclosure Environmental Monitoring Unit is determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. In addition, the device field may contain all zeroes. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. Note that the content of the rack_num field will not be valid until a future release. Note also that the content of the fed_class, al_pa, and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 55: c00287657

Command View EVA event codes

55Event code definitions application notes

1561 88030619 2 6 19 Storage Cell: %1 Event ID: %2 Description: A Drive Enclosure Environmental Monitoring Unit has completed updating its code. It is now safe to power down this drive enclosure. The identity of the Drive Enclosure Environmental Monitoring Unit is contained in the device field. The Fibre Channel port used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the cerp_id field. The HSV controller internal Fibre Channel port number used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the port field. The missing_port and missing_cerp_id fields are unused. The location of the Drive Enclosure Environmental Monitoring Unit is contained in the rack_num and dencl_num fields. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the fed_class, al_pa, and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 56: c00287657

Command View EVA event codes

56 Event code definitions application notes

1562 8803061a 6 6 1a Storage Cell: %1 Event ID: %2 Description: A physical disk drive has exceeded its soft error threshold. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The location of the physical disk drive is determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num,dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the fed_class, cdb, and sense_data fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

1563 8803061b 2 6 1b Storage Cell: %1 Event ID: %2 Description: A HSV controller now has an address on the enclosure address bus. The HSV controller location has been identified. The location of the HSV controller is contained in the rack_num and dencl_num fields. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the bay, fed_class, al_pa, cerp_id, port, and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The missing_port and missing_cerp_id fields are unused. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 57: c00287657

Command View EVA event codes

57Event code definitions application notes

1564 8803061c 3 6 1c Storage Cell: %1 Event ID: %2 Description: An outbound frame targeted to a physical disk drive has timed out. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The location of the physical disk drive is determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The command issued to the physical disk drive is contained in the cmd field. Note that in this case the content of the error field is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 58: c00287657

Command View EVA event codes

58 Event code definitions application notes

1565 8803061d 3 6 1d Storage Cell: %1 Event ID: %2 Description: A Fibre Channel exchange to a physical disk drive has completed but is missing data. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The location of the physical disk drive is determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The command issued to the physical disk drive is contained in the cmd field. Note that in this case the content of the error field is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 59: c00287657

Command View EVA event codes

59Event code definitions application notes

1566 8803061e 6 6 1e Storage Cell: %1 Event ID: %2 Description: A HSV controller has detected only one port of a Fibre Channel device. This Fibre Channel device has entered the Single Port on Fibre state which should be corrected as soon as possible. The identity of the Fibre Channel device is contained in the device field. The Fibre Channel port still able to communicate with the Fibre Channel device is contained in the cerp_id field. The HSV controller internal Fibre Channel port number able to communicate with the Fibre Channel device is contained in the port field. The Fibre Channel port unable to communicate with the Fibre Channel device is contained in the missing_cerp_id field. The HSV controller internal Fibre Channel port number unable to communicate with the Fibre Channel device is contained in the missing_port field. The arbitrated loop physical address of the Fibre Channel device is contained in the al_pa field. The location of the Fibre Channel device is determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the fed_class, and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 60: c00287657

Command View EVA event codes

60 Event code definitions application notes

1567 8803061f 2 6 1f Storage Cell: %1 Event ID: %2 Description: A previously reported Fibre Channel device with only one port has been corrected and redundancy has been restored. The device is no longer in the Single Port on Fibre state. The identity of the Fibre Channel device is contained in the device field. The Fibre Channel port used to communicate with the Fibre Channel device is contained in the cerp_id field. The HSV controller internal Fibre Channel port number used to communicate with the Fibre Channel device is contained in the port field. The missing_port and missing_cerp_id fields are unused. The arbitrated loop physical address of the Fibre Channel device is contained in the al_pa field. The location of the Fibre Channel device is determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the fed_class, and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 61: c00287657

Command View EVA event codes

61Event code definitions application notes

1568 88030620 6 6 20 Storage Cell: %1 Event ID: %2 Description: An unsupported Fibre Channel device has been detected. The drive has been failed to prevent possible data corruption or system instability. The identity of the Fibre Channel device is contained in the device field. The Fibre Channel port used to communicate with the Fibre Channel device is contained in the cerp_id field. The HSV controller internal Fibre Channel port number used to communicate with the Fibre Channel device is contained in the port field. The arbitrated loop physical address of the Fibre Channel device is contained in the al_pa field. The missing_port and missing_cerp_id fields are unused. The location of the Fibre Channel device is determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the fed_class and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 62: c00287657

Command View EVA event codes

62 Event code definitions application notes

1569 88030621 2 6 21 Storage Cell: %1 Event ID: %2 Description: A Fibre Channel device with the incorrect block size has been detected. The identity of the Fibre Channel device is contained in the device field. The Fibre Channel port used to communicate with the Fibre Channel device is contained in the cerp_id field. The HSV controller internal Fibre Channel port number used to communicate with the Fibre Channel device is contained in the port field. The arbitrated loop physical address of the Fibre Channel device is contained in the al_pa field. The missing_port and missing_cerp_id fields are unused. The location of the Fibre Channel device is determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the fed_class and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 63: c00287657

Command View EVA event codes

63Event code definitions application notes

1570 88030622 2 6 22 Storage Cell: %1 Event ID: %2 Description: An unrecognized Fibre Channel physical disk drive or an old physical disk drive firmware revision has been detected by the physical disk drive firmware load process. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The bypass_reason field is invalid. The location of the physical disk drive is determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num, al_pa and bay fields is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. Note that the content of the rack_num field will not be valid until a future release. The pid field contains the SCSI Inquiry Product Identification obtained from the physical disk drive. The rev field contains the current firmware revision obtained from the physical disk drive. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 64: c00287657

Command View EVA event codes

64 Event code definitions application notes

1571 88030623 2 6 23 Storage Cell: %1 Event ID: %2 Description: A HSV controller is about to retry a failed port. The Fibre Channel port that is about to be retried is contained in the cerp_id field. The HSV controller internal Fibre Channel port number about to be retried is contained in the port field. Note that in this case the content of the bay, rack_num, fed_class, al_pa, dencl_num, device, and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The missing_port and missing_cerp_id fields are unused. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

1572 88030624 2 6 24 Storage Cell: %1 Event ID: %2 Description: A HSV controller has successfully retried a failed port. The Fibre Channel port that has been restarted is contained in the cerp_id field. The HSV controller internal Fibre Channel port number that has been restarted is contained in the port field. Note that in this case the content of the bay, rack_num, fed_class, al_pa, dencl_num, device, and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The missing_port and missing_cerp_id fields are unused. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 65: c00287657

Command View EVA event codes

65Event code definitions application notes

1573 88030625 6 6 25 Storage Cell: %1 Event ID: %2 Description: A Drive Enclosure Environmental Monitoring Unit has failed to assign a hard address to a physical disk drive on the loop. The device field contains the identity of the enclosure. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The al_pa field contains the expected AL_PA, and the num_times field contains the actual AL_PA. The missing_port and missing_cerp_id fields are unused. The location of the physical disk drive is determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. Note that the content of the rack_num field will not be valid until a future release. Note that in this case the content of the fed_class is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 66: c00287657

Command View EVA event codes

66 Event code definitions application notes

1574 88030626 6 6 26 Storage Cell: %1 Event ID: %2 Description: A Drive Enclosure Environmental Monitoring Unit has failed to assign an address to a physical disk drive on the loop. This has occurred because another physical disk drive has already obtained this AL_PA. The device field contains the identity of the enclosure. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The al_pa field contains the AL_PA that was stolen. The missing_port and missing_cerp_id fields are unused. The location of the physical disk drive is determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the fed_class and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 67: c00287657

Command View EVA event codes

67Event code definitions application notes

1575 88030627 6 6 27 Storage Cell: %1 Event ID: %2 Description: A Drive Enclosure Environmental Monitoring Unit has failed to assign address(s) to a physical disk drive on the loop. Soft addressing was detected for this enclosure. The device field contains the identity of the enclosure. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The missing_port and missing_cerp_id fields are unused. The location of the physical disk drive is determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the fed_class, al_pa, and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

1576 88030628 2 6 28 Storage Cell: %1 Event ID: %2 Description: The retry count for an OB task assigned to a Drive Enclosure Environmental Monitoring Unit has been exhausted. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The peb array contains the task list that was intended to be sent to the Drive Enclosure Environmental Monitoring Unit. The peq_frz_prod_index field contains the task that was being retried. The peq_prod_index field contains the drive enclosure where the physical disk drive used to communicate with the Drive Enclosure Environmental Monitoring Unit is located. The peq_cons_index field identifies the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) used to communicate with the physical disk drive that was used to communicate with the Drive Enclosure Environmental Monitoring Unit. The failure_cause field contains the bay where the physical disk drive used to communicate with the Drive Enclosure Environmental Monitoring Unit.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 68: c00287657

Command View EVA event codes

68 Event code definitions application notes

1577 88030629 2 6 29 Storage Cell: %1 Event ID: %2 Description: The HSV controller has sent a Basic Link Service command Abort Sequence Frame. The original work is described in this event. The identity of the intended target is contained in the device field. The Fibre Channel port over which the work was sent is identified in the cerp_id field. The HSV controller internal Fibre Channel port over which the work was sent is contained in the port field. The arbitrated loop physical address of the intended target is contained in the al_pa field. The location of the intended target is determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The command issued to the intended target is contained in the cmd field. Note that in this case the content of the error field is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 69: c00287657

Command View EVA event codes

69Event code definitions application notes

1578 8803062a 2 6 2a Storage Cell: %1 Event ID: %2 Description: The HSV controller has sent an Extended Link Service command Reinstate Recovery Qualifier. The original work is described in this event. The identity of the intended target is contained in the device field. The Fibre Channel port over which the work was sent is identified in the cerp_id field. The HSV controller internal Fibre Channel port over which the work was sent is contained in the port field. The arbitrated loop physical address of the intended target is contained in the al_pa field. The location of the intended target is determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The command issued to the intended target is contained in the cmd field. Note that in this case the content of the error field is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

1579 8803062b 6 6 2b Storage Cell: %1 Event ID: %2 Description: A physical disk drive was bypassed rendering it unusable. The physical disk drive is unusable because a Drive Enclosure Environmental Monitoring Unit bypassed a drive bay or the physical disk drive left itself bypassed. The physical disk drive is not available to the HSV controllers and will not be displayed by the HSV element manager GUI. The physical disk drive fault led will be lit to indicate that it is unusable. The Fibre Channel port over which this condition was detected is identified in the cerp_id field. The HSV controller internal Fibre Channel port over which this condition was detected is contained in the port field. The al_pa field is invalid. The location of the physical disk drive is as indicated by the content of the rack_num, dencl_num, and bay fields. Note that the content of the rack_num field will not be valid until a future release. The bypass_reason field is used to indicate how the physical disk drive was bypassed: 1 = The physical disk drive left itself bypassed 2= The Drive Enclosure Environmental Monitoring Unit bypassed the drive bay The Drive Enclosure Environmental Monitoring Unit is identified in the device field. Additionally, the content of the pid, rev, and enclosures array fields is undefined in this case.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 70: c00287657

Command View EVA event codes

70 Event code definitions application notes

1580 8803062c 2 6 2c Storage Cell: %1 Event ID: %2 Description: One or more media defects were detected on a physical disk drive. The affected physical disk drive is identified in the device field. The Fibre Channel port over which the media defect(s) was detected is identified in the cerp_id field. The HSV controller internal Fibre Channel port number over which the media defect(s) was detected is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The Logical Block Address of each media defect is contained in a separate entry of the hdr_cdb array. Only nonzero values in the hdr_cdb array entries are valid. The location of the physical disk drive is determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. Note that the content of the rack_num field will not be valid until a future release.

1581 8803062d 2 6 2d Storage Cell: %1 Event ID: %2 Description: An HSV controller issued a directed LIP to an arbitrated loop physical address. The Fibre Channel port over which the directed LIP was issued is identified in the cerp_id field. The HSV controller internal Fibre Channel port number over which the directed LIP was issued is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field.

1582 8803062e 2 6 2e Storage Cell: %1 Event ID: %2 Description: An HSV controller has detected Loop Receiver Failures. The Fibre Channel port over which the Loop Receiver Failures were detected is identified in the cerp_id field. TheHSV controller internal Fibre Channel port number over which the Loop Receiver Failures were detected is contained in the port field. The counts and the AL_PAs of the Loop Receiver Failures are contained in a separate entry of the hdr_cdb array. Only nonzero values in the hdr_cdb array entries are valid. The affected HSV controller is identified in the device field. Note that in this case the content of the al_pa, dencl_num, bay, and rack_num fields are undefined.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 71: c00287657

Command View EVA event codes

71Event code definitions application notes

1584 88030630 6 6 30 Storage Cell: %1 Event ID: %2 Description: A HSV controller has detected only one port of all Fibre Channel devices in an enclosure. These Fibre Channel devices have entered the Single Port on Fibre state which should be corrected as soon as possible. The identity of the Fibre Channel device enclosure is contained in the device field. The Fibre Channel port still able to communicate with the Fibre Channel device is contained in the cerp_id field. The HSV controller internal Fibre Channel port number able to communicate with the Fibre Channel device is contained in the port field. The Fibre Channel port unable to communicate with the Fibre Channel device is contained in the missing_cerp_id field. The HSV controller internal Fibre Channel port number unable to communicate with the Fibre Channel device is contained in the missing_port field. The al_pa amd bay fields are invalid. The location of the Fibre Channel enclosure is determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the fed_class, and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 72: c00287657

Command View EVA event codes

72 Event code definitions application notes

1585 88030631 2 6 31 Storage Cell: %1 Event ID: %2 Description: A previously reported Fibre Channel device enclosure with only one port has been corrected and redundancy has been restored. The devices in the enclosure are no longer in the Single Port on Fibre state. The identity of the Fibre Channel device enclosure is contained in the device field. The Fibre Channel port used to communicate with the Fibre Channel device enclosure is contained in the cerp_id field. The HSV controller internal Fibre Channel port number used to communicate with the Fibre Channel device is contained in the port field. The al_pa, bay, missing_port, and missing_cerp_id fields are invalid. The location of the Fibre Channel device is determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num amd dencl_num fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the fed_class, and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

1586 88030632 6 6 32 Storage Cell: %1 Event ID: %2 Description: A HSV controller has detected only one port of all Fibre Channel devices on a loop. These Fibre Channel devices have entered the Single Port on Fibre state which should be corrected as soon as possible. The device, al_pa, dencl_num, and bay fields are all invalid. The Fibre Channel port still able to communicate with the Fibre Channel device is contained in the cerp_id field. The HSV controller internal Fibre Channel port number able to communicate with the Fibre Channel device is contained in the port field. The Fibre Channel port unable to communicate with the Fibre Channel device is contained in the missing_cerp_id field. The HSV controller internal Fibre Channel port number unable to communicate with the Fibre Channel device is contained in the missing_port field.

1587 88030633 2 6 33 Storage Cell: %1 Event ID: %2 Description: A previously reported Fibre Channel loop with only one port has been corrected and redundancy has been restored. The devices on the loop are no longer in the Single Port on Fibre state. The device, al_pa, dencl_num, bay, missing_port, and missing_cerp_id fields are invalid. The Fibre Channel port used to communicate with the Fibre Channel devices is contained in the cerp_id field. The HSV controller internal Fibre Channel port number used to communicate with the Fibre Channel devices is contained in the port field.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 73: c00287657

Command View EVA event codes

73Event code definitions application notes

1792 88030700 3 7 0 Storage Cell: %1 Event ID: %2 Description: Allocation of a Virtual Disk has stalled due to insufficient space in the Disk Group caused by the failure or pulling of a physical disk drive. The tag1 field contains the identity of the Virtual Disk. The tag2 field contains the identity of the Disk Group. The values that may be found in the state field are as follows: 0 = Attempting to retry the allocation 1 = Awaiting a leveling event (a drive needs to be inserted).

1793 88030701 3 7 1 Storage Cell: %1 Event ID: %2 Description: Expansion of a Virtual Disk has stalled due to insufficient space in the Disk Group caused by the failure or pulling of a physical disk drive. The tag1 field contains the identity of the Virtual Disk. The tag2 field contains the identity of the Disk Group. The values that may be found in the state field are as follows: 0 = Attempting to retry the expansion 1 = Awaiting a leveling event (a drive needs to be inserted).

1794 88030702 2 7 2 Storage Cell: %1 Event ID: %2 Description: Leveling of capacity in a Disk Group has started. The identity of the Disk Group is contained in the tag1 field.

1795 88030703 2 7 3 Storage Cell: %1 Event ID: %2 Description: Leveling of capacity in a Disk Group has finished. The identity of the Disk Group is contained in the tag1 field.

1796 88030704 2 7 4 Storage Cell: %1 Event ID: %2 Description: A member management operation has started due to the appearance or disappearance of a physical disk drive. If available, the tag1 field contains the identity of the physical disk drive. The tag2 field contains the disk unit block in which physical disk drive resides. The values that may be found in the state field are as follows: 2 = Reconstructing 4 = Migrating 6 = Reverting.

1797 88030705 2 7 5 Storage Cell: %1 Event ID: %2 Description: A member management operation has finished. If available, the tag1 field contains the identity of the physical disk drive. The tag2 field contains the disk unit block in which the physical disk drive resides. The values that may be found in the state field are as follows: 2 = Reconstructing 4 = Migrating 6 = Reverting The status field contains one of the following values: 1 = PSEGS NONE ( Reconstruction of data was successful ) 2 = PSEGS RAID0 ( Could not reconstruct RAID0 data ) 4 = PSEGS RAID5 ( Could not reconstruct RAID5 data ) 8 = PSEGS RAID1 ( Could not reconstruct RAID1 data ).

1798 88030706 2 7 6 Storage Cell: %1 Event ID: %2 Description: A Disk Group has started changing its internal structure due to the appearance or disappearance of a Volume. The identity of the Disk Group is contained in the tag1 field. The values that may be found in the state field are as follows: 4 = Merge began 8 = Split began.

1799 88030707 2 7 7 Storage Cell: %1 Event ID: %2 Description: A Disk Group has finished changing its internal structure due to the appearance or disappearance of a volume. The identity of the Disk Group is contained in the tag1 field. The values that may be found in the state field are as follows: 4 = Merge completed 8 = Split completed.

2305 88030901 2 9 1 Storage Cell: %1 Event ID: %2 Description: The state of the Physical Disk Drive identified in the handle field has transitioned to the NORMAL state. The value.ul1 field contains the new state: 1 (NORMAL). The value.ul2 field contains the old state. The state values that may be in the value.ul2 field are as follows: 2 = Degraded 3 = Failed 4 = Not present 5 = Single Port on Fibre The enclosure number, bay number, and rack number where the Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1], attribute.value.u32[2] fields, respectively. The attribute.type field contains value 1. The rack number in the attribute.value.u32[2] field will not contain a valid value until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 74: c00287657

Command View EVA event codes

74 Event code definitions application notes

2306 88030902 2 9 2 Storage Cell: %1 Event ID: %2 Description: The state of the Volume identified in the handle field has changed. The value.ul1 field contains the new state. The value.ul2 field contains the old state. The state values that may be found in the value.ul1 and value.ul2 fields are as follows: 1 = Normal - Volume is present and operating normally 2 = Migrating - Data from this volume is being moved to other storage in this Disk Group 3 = Missing - Volume is inaccessible 4 = Reconstructing - Volume is inaccessible; redundant data is being regenerated and moved to other storage in this Disk Group 5 = Completing - This previously inaccessible volume has become accessible; data migration is being completed 6 = Reverting - This previously inaccessible volume has become accessible; data is being regenerated 7 = Failed - Volume is not being used in the Disk Group; disk errors are preventing normal usage.

2307 88030903 2 9 3 Storage Cell: %1 Event ID: %2 Description: The state of the internal Logical Disk associated with the Virtual Disk identified in the handle field has changed. The value.ul1 field contains the new state. The value.ul2 field contains the old state. The state values that may be found in the value.ul1 and value.ul2 fields are as follows: 1 = Normal 2 = Replacement delay in progress 3 = Redundancy lost, restore in progress 4 = Redundancy lost, restore stalled 5 = Failed 6 = Creation in progress 7 = Snapshot is inoperative due to lack of snapshot space 8 = Deletion in progress 9 = Capacity change in progress 10 = Inoperative due to data lost 11 = Capacity reservation in progress 12 = Capacity unreservation in progress.

2308 88030904 2 9 4 Storage Cell: %1 Event ID: %2 Description: The state of the HSV controller identified in the handle field has transitioned to the NORMAL state. The value.ul1 field contains the new state: 1 (NORMAL). The value.ul2 field contains the old state: 3 (FAILED).

2309 88030905 2 9 5 Storage Cell: %1 Event ID: %2 Description: The state of a battery assembly within the HSV controller identified in the handle field has changed. The value.ul1 field contains the new state. The value.ul2 field contains the old state. The state values that may be found in the value.ul1 and value.ul2 fields are as follows: 1 = Battery System Hold-up Time is greater than 96 hours 3 = Battery System Hold-up Time is greater than 0 and less than 96 hours 5 = Battery System Hold-up Time is zero hours.

2310 88030906 6 9 6 Storage Cell: %1 Event ID: %2 Description: The state of the Volume identified in the handle field has transitioned to the MISSING state. The value.ul1 field contains the new state: 3 (MISSING). The value.ul2 field contains the old state. The state values that may be found in the value.ul2 field are as follows: 1 = Normal - Volume is present and operating normally 2 = Migrating - Data from this volume is being moved to other storage in this Disk Group 4 = Reconstructing - Volume is inaccessible; redundant data is being regenerated and moved to other storage in this Disk Group 5 = Completing - This previously inaccessible volume has become accessible; data migration is being completed 6 = Reverting - This previously inaccessible volume has become accessible; data is being regenerated 7 = Failed - Volume is not being used in the Disk Group; disk errors are preventing normal usage.

2311 88030907 2 9 7 Storage Cell: %1 Event ID: %2 Description: The state of the Fibre Channel port identified in the attribute.value.str field and located on the rear panel of the HSV controller identified in the handle field has transitioned to the NORMAL state. The attribute.type field contains the value 4. The value.ul1 field contains the new state: 1 (NORMAL). The value.ul2 field contains the old state: 2 (FAILED). Note that the HSV controller’s internal identity of the affected Fibre Channel port is contained in the secondary_id field.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 75: c00287657

Command View EVA event codes

75Event code definitions application notes

2312 88030908 3 9 8 Storage Cell: %1 Event ID: %2 Description: The Occupancy Alarm Level threshold has been reached for the Disk Group identified in the handle field.

2313 88030909 2 9 9 Storage Cell: %1 Event ID: %2 Description: The Resource Availability state of the Volume identified in the handle field has transitioned to the SUFFICIENT state. The value.ul1 field contains the new state: 0 (SUFFICIENT). The value.ul2 field contains the old state: 1 (INSUFFICIENT).

2314 8803090a 2 9 a Storage Cell: %1 Event ID: %2 Description: The Data Availability state of the Logical Disk identified in the handle field has transitioned to the NORMAL state. The value.ul1 field contains the new state: 0 (NORMAL). The value.ul2 field contains the old state: 1 (DATA LOST).

2316 8803090c 2 9 c Storage Cell: %1 Event ID: %2 Description: The Snapclone Logical Disk identified in the handle field has completed the unsharing operation. The secondary_id field contains the noid of the associated successor internal Logical Disk.

2317 8803090d 2 9 d Storage Cell: %1 Event ID: %2 Description: The state of the Quorum Disk flag for the Volume identified in the handle field has changed. The value.ul1 field contains the new state of the Quorum Disk flag. The value.ul2 field contains the old state of the Quorum Disk flag. The state values that may be found in the value.ul1 and value.ul2 fields are as follows: 0 = Not quorum disk 1 = Quorum disk.

2318 8803090e 3 9 e Storage Cell: %1 Event ID: %2 Description: The temperature trip point for a temperature sensor located within an HSV controller has been reached. The HSV controller is identified in the handle field.

2319 8803090f 3 9 f Storage Cell: %1 Event ID: %2 Description: A temperature sensor located within the HSV controller identified in the handle field is approaching its trip point. The value.ul1 field contains the current temperature reading from that sensor in Celsius. The secondary_id field contains the temperature trip point in Celsius.

2321 88030911 2 9 11 Storage Cell: %1 Event ID: %2 Description: The Blower Present flag for the ‘1’ blower assembly located within the HSV controller identified in the handle field has transitioned from the NOT PRESENT to PRESENT state indicating that the blower has been reinstalled. The secondary_id field contains the ‘1’ blower assembly internal identifier value: 1. The value.ul1 field contains the new state of the Blower Present flag: 1 (PRESENT). The value.ul2 field contains the old state of the Blower Present flag: 0 (NOT PRESENT).

2322 88030912 6 9 12 Storage Cell: %1 Event ID: %2 Description: The ‘1’ blower located within the HSV controller identified in the handle field is running slower than the lowest acceptable speed. The secondary_id field contains the ‘1’ blower assembly internal identifier value: 1. The value.ul1 field contains the current speed of the ‘1’ blower. The value.ul2 field contains the lowest acceptable speed for the ‘1’ blower.

2323 88030913 2 9 13 Storage Cell: %1 Event ID: %2 Description: One of the voltage sensors located within the HSV controller identified in the handle field has reported a voltage that is out of range. The value.ul1 field contains the out of range voltage value. The secondary_id field contains the specific voltage threshold value (i.e., 12V, 5V, 3.3V, 2.5V or 2V). Note that the voltages are expressed in millivolts--e.g.,12.5V is expressed as 12500.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 76: c00287657

Command View EVA event codes

76 Event code definitions application notes

2324 88030914 6 9 14 Storage Cell: %1 Event ID: %2 Description: The state of the Volume identified in the handle field has transitioned to the FAILED state. The value.ul1 field contains the new state: 7 (FAILED). The value.ul2 field contains the old state. The state values that may be found in the value.ul2 fields are as follows: 1 = Normal - Volume is present and operating normally 2 = Migrating - Data from this volume is being moved to other storage in this Disk Group 3 = Missing - Volume is inaccessible 4 = Reconstructing - Volume is inaccessible; redundant data is being regenerated and moved to other storage in this Disk Group 5 = Completing - This previously inaccessible volume has become accessible; data migration is being completed 6 = Reverting - This previously inaccessible volume has become accessible; data is being regenerated.

2325 88030915 6 9 15 Storage Cell: %1 Event ID: %2 Description: An HSV controller has failed. The state of the HSV controller identified in the handle field has transitioned to the FAILED state. The value.ul1 field contains the new state: 3 (FAILED). The value.ul2 field contains the old state: 1 (NORMAL).

2327 88030917 6 9 17 Storage Cell: %1 Event ID: %2 Description: An HSV controller’s battery assembly has been removed. The Battery Present flag for battery assembly ‘1’ located within the HSV controller identified in the handle field has changed from PRESENT to NOT PRESENT indicating that the battery assembly was removed. The secondary_id field contains the battery assembly ‘1’ internal identifier value: 1. The value.ul1 field contains the new state of the Battery Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old state of the Battery Present flag: 1 (PRESENT).

2328 88030918 2 9 18 Storage Cell: %1 Event ID: %2 Description: The Battery In Use flag for battery assembly ‘1’ located within the HSV controller identified in the handle field has transitioned from the NOT IN USE to IN USE state indicating that the battery assembly is functioning properly. The secondary_id field contains the battery assembly ‘1’ internal identifier value: 1. The value.ul1 field contains the new state of the Battery In Use flag: 1 (IN USE). The value.ul2 field contains the old state of the Battery In Use flag: 0 (NOT IN USE).

2329 88030919 2 9 19 Storage Cell: %1 Event ID: %2 Description: One of the voltage sensors located within the HSV controller identified in the handle field has reported a voltage that indicates that a voltage that was previously out of range has returned to the normal range. The value.ul1 field contains the normal range voltage value. The secondary_id field contains the voltage threshold value (i.e., 12V, 5V, 3.3V, 2.5V or 2V). Note that the voltages are expressed in thousands--e.g., 12.5V is expressed as 12500.

2330 8803091a 3 9 1a Storage Cell: %1 Event ID: %2 Description: The battery assembly voltage regulator located within the HSV controller identified in the handle field is offline.

2331 8803091b 2 9 1b Storage Cell: %1 Event ID: %2 Description: The state of the Disk Group identified in the handle field has transitioned to the NORMAL state. The value.ul1 field contains the new Disk Group state: 1 (NORMAL). The value.ul2 field contains the old Disk Group state. The state values that may be found in the value.ul2 field are as follows: 2 = Disk Group with no redundancy is inoperative 3 = Disk Group with parity redundancy is inoperative 4 = Disk Group with mirrored redundancy is inoperative 5 = Disk Group with no redundancy is inoperative, marked for re-use 6 = Disk Group with parity redundancy is inoperative, marked for re-use 7 = Disk Group with mirrored redundancy is inoperative, marked for re-use.

2332 8803091c 2 9 1c Storage Cell: %1 Event ID: %2 Description: The Occupancy Alarm Level for the Disk Group identified in the handle field has returned to the normal range.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 77: c00287657

Command View EVA event codes

77Event code definitions application notes

2333 8803091d 6 9 1d Storage Cell: %1 Event ID: %2 Description: An HSV controller’s battery assembly has malfunctioned. The Battery In Use flag for battery assembly ‘1’ located within the HSV controller identified in the handle field has transitioned from the IN USE to NOT IN USE state indicating that the battery assembly has malfunctioned. The secondary_id field contains the battery assembly ‘1’ internal identifier value: 1. The value.ul1 field contains the new state of the Battery In Use flag: 0 (NOT IN USE). The value.ul2 field contains the old state of the Battery In Use flag: 1 (IN USE).

2334 8803091e 2 9 1e Storage Cell: %1 Event ID: %2 Description: The Battery Present flag for battery assembly ‘1’ located within the HSV controller identified in the handle field has changed from NOT PRESENT to PRESENT indicating that the battery assembly was reinstalled. The secondary_id field contains the battery assembly ‘1’ internal identifier value: 1. The value.ul1 field contains the new state of the Battery Present flag: 1 (PRESENT). The value.ul2 field contains the old state of the Battery Present flag: 0 (NOT PRESENT).

2335 8803091f 6 9 1f Storage Cell: %1 Event ID: %2 Description: An HSV controller’s battery assembly has been removed. The Battery Present flag for battery assembly ‘2’ located within the HSV controller identified in the handle field has changed from PRESENT to NOT PRESENT indicating that the battery assembly was removed. The secondary_id field contains the battery assembly ‘2’ internal identifier value: 2. The value.ul1 field contains the new state of the Battery Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old state of the Battery Present flag: 1 (PRESENT).

2336 88030920 2 9 20 Storage Cell: %1 Event ID: %2 Description: The Battery Present flag for battery assembly ‘2’ located within the HSV controller identified in the handle field has changed from NOT PRESENT to PRESENT indicating that the battery assembly was reinstalled. The secondary_id field contains the battery assembly ‘2’ internal identifier value: 2. The value.ul1 field contains the new state of the Battery Present flag: 1 (PRESENT). The value.ul2 field contains the old state of the Battery Present flag: 0 (NOT PRESENT).

2337 88030921 2 9 21 Storage Cell: %1 Event ID: %2 Description: The Battery In Use flag for battery assembly ‘2’ located within the HSV controller identified in the handle field has transitioned from the NOT IN USE to IN USE state indicating that the battery assembly is functioning properly. The secondary_id field contains the battery assembly ‘2’ internal identifier value: 2. The value.ul1 field contains the new state of the Battery In Use flag: 1 (IN USE). The value.ul2 field contains the old state of the Battery In Use flag: 0 (NOT IN USE).

2338 88030922 6 9 22 Storage Cell: %1 Event ID: %2 Description: An HSV controller’s battery assembly has malfunctioned. The Battery In Use flag for battery assembly ‘2’ located within the HSV controller identified in the handle field has transitioned from the IN USE to NOT IN USE state indicating that the battery assembly has malfunctioned. The secondary_id field contains the battery assembly ‘2’ internal identifier value: 2. The value.ul1 field contains the new state of the Battery In Use flag: 0 (NOT IN USE). The value.ul2 field contains the old state of the Battery In Use flag: 1 (IN USE).

2339 88030923 6 9 23 Storage Cell: %1 Event ID: %2 Description: The Blower Present flag for the ‘2’ blower assembly located within the HSV controller identified in the handle field has transitioned from the PRESENT to NOT PRESENT state indicating that the blower has been removed. The secondary_id field contains the ‘2’ blower assembly internal identifier value: 2. The value.ul1 field contains the new state of the Blower Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old state of the Blower Present flag: 1 (PRESENT).

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 78: c00287657

Command View EVA event codes

78 Event code definitions application notes

2340 88030924 2 9 24 Storage Cell: %1 Event ID: %2 Description: The Blower Present flag for the ‘2’ blower assembly located within the HSV controller identified in the handle field has transitioned from the NOT PRESENT to PRESENT state indicating that the blower has been reinstalled. The secondary_id field contains the ‘2’ blower assembly internal identifier value: 2. The value.ul1 field contains the new state of the Blower Present flag: 1 (PRESENT). The value.ul2 field contains the old state of the Blower Present flag: 0 (NOT PRESENT).

2341 88030925 6 9 25 Storage Cell: %1 Event ID: %2 Description: The ‘2’ blower located within the HSV controller identified in the handle field is running slower than the lowest acceptable speed. The secondary_id field contains the ‘2’ blower assembly internal identifier value: 2. The value.ul1 field contains the current speed of the ‘2’ blower. The value.ul2 field contains the lowest acceptable speed for the ‘2’ blower.

2342 88030926 6 9 26 Storage Cell: %1 Event ID: %2 Description: The Blower/Power Supply Present flag for the ‘1’ blower/power supply assembly located within the HSV controller identified in the handle field has transitioned from the PRESENT to NOT PRESENT state indicating that the blower/power supply has been removed, or AC power has been removed from the power supply. The secondary_id field contains the ‘1’ blower/power supply assembly internal identifier value: 1. The value.ul1 field contains the new state of the Blower/Power Supply Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old state of the Blower/Power Supply Present flag: 1 (PRESENT).

2343 88030927 2 9 27 Storage Cell: %1 Event ID: %2 Description: The Blower/Power Supply Present flag for the ‘1’ blower/power supply assembly located within the HSV controller identified in the handle field has transitioned from the NOT PRESENT to PRESENT state indicating that the blower/power supply has been reinstalled, or AC power has been reinstalled to the power supply. The secondary_id field contains the ‘1’ blower/power supply assembly internal identifier value: 1. The value.ul1 field contains the new state of the Blower/Power Supply Present flag: 1 (PRESENT). The value.ul2 field contains the old state of the Blower/Power Supply Present flag: 0 (NOT PRESENT).

2344 88030928 6 9 28 Storage Cell: %1 Event ID: %2 Description: The Blower/Power Supply Present flag for the ‘2’ blower/power supply assembly located within the HSV controller identified in the handle field has transitioned from the PRESENT to NOT PRESENT state indicating that the blower/power supply has been removed, or AC power has been removed from the power supply. The secondary_id field contains the ‘2’ blower/power supply assembly internal identifier value: 1. The value.ul1 field contains the new state of the Blower/Power Supply Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old state of the Blower/Power Supply Present flag: 1 (PRESENT).

2345 88030929 2 9 29 Storage Cell: %1 Event ID: %2 Description: The Blower/Power Supply Present flag for the ‘2’ blower/power supply assembly located within the HSV controller identified in the handle field has transitioned from the NOT PRESENT to PRESENT state indicating that the blower/power supply has been reinstalled. or AC power has been reinstalled to the power supply. The secondary_id field contains the ‘2’ blower/power supply assembly internal identifier value: 1. The value.ul1 field contains the new state of the Blower/Power Supply Present flag: 1 (PRESENT). The value.ul2 field contains the old state of the Blower/Power Supply Present flag: 0 (NOT PRESENT).

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 79: c00287657

Command View EVA event codes

79Event code definitions application notes

2346 8803092a 6 9 2a Storage Cell: %1 Event ID: %2 Description: The ‘1’ blower/power supply located within the HSV controller identified in the handle field is running slower than the lowest acceptable speed. The secondary_id field contains the ‘1’ blower/power supply assembly internal identifier value: 1. The value.ul1 field contains the current speed of the ‘1’ blower/power supply. The value.ul2 field contains the lowest acceptable speed for the ‘1’ blower/power supply.

2347 8803092b 6 9 2b Storage Cell: %1 Event ID: %2 Description: The ‘2’ blower/power supply located within the HSV controller identified in the handle field is running slower than the lowest acceptable speed. The secondary_id field contains the ‘2’ blower/power supply assembly internal identifier value: 2. The value.ul1 field contains the current speed of the ‘2’ blower/power supply. The value.ul2 field contains the lowest acceptable speed for the ‘2’ blower/power supply.

2348 8803092c 3 9 2c Storage Cell: %1 Event ID: %2 Description: The state of a battery assembly within the HSV controller identified in the handle field has transitioned to the Battery System Hold-up Time is zero hours state. The value.ul1 field contains the new state 5: (Battery System Hold-up Time is zero hours). The value.ul2 field contains the old state. The state values that may be found in the value.ul2 field are as follows: 1 = Battery System Hold-up Time is greater than 96 hours 3 = Battery System Hold-up Time is greater than 0 and less than 96 hours 5 = Battery System Hold-up Time is zero hours.

2349 8803092d 6 9 2d Storage Cell: %1 Event ID: %2 Description: The Resource Availability state of the Volume identified in the handle field has transitioned to the INSUFFICIENT state. The value.ul1 field contains the new state: 1 (INSUFFICIENT). The value.ul2 field contains the old state: 0 (SUFFICIENT).

2350 8803092e 2 9 2e Storage Cell: %1 Event ID: %2 Description: The HSV controller identified in the handle field rejected a login attempt. The value.ul1 and value.ul2 fields contain words [0] and [1], respectively, of the World Wide Name of the host adapter that originated the rejected login attempt. The secondary_id field contains the reason for the rejection as follows: 50 = The host is already logged in 101 = Maximum number of logins is exceeded 102 = Invalid cookie was sent 106 = The password is not set on the HSV controller.

2351 8803092f 2 9 2f Storage Cell: %1 Event ID: %2 Description: The HSV controller identified in the handle field processed a Storage System Management Interface command with the result of non-success return code. The value.ul1 field contains internal the command type. The value.ul2 field contains the internal return code. The attribute.value.obj field contains the internal target and internal version of the command.

2352 88030930 2 9 30 Storage Cell: %1 Event ID: %2 Description: The HSV controller identified in the handle field has updated the physical disk drive map for the loop pair identified in the secondary_id field. The value.ul1 field contains the new internal map generation number. The value.ul2 field contains the old internal map generation number.

2353 88030931 6 9 31 Storage Cell: %1 Event ID: %2 Description: The state of the Physical Disk Drive identified in the handle field has transitioned to the DEGRADED state. The value.ul1 field contains the new state: 2 (DEGRADED). The value.ul2 field contains the old state. The state values that may be in the value.ul2 field are as follows: 1 = Normal 3 = Failed 4 = Not present 5 = Single Port on Fibre The enclosure number, bay number, and rack number where the Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1], attribute.value.u32[2] fields, respectively. The attribute.type field contains value 1. The rack number in the attribute.value.u32[2] field will not contain a valid value until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 80: c00287657

Command View EVA event codes

80 Event code definitions application notes

2354 88030932 6 9 32 Storage Cell: %1 Event ID: %2 Description: The state of the Physical Disk Drive identified in the handle field has transitioned to the FAILED state. The value.ul1 field contains the new state: 3 (FAILED). The value.ul2 field contains the old state. The state values that may be in the value.ul2 field are as follows: 1 = Normal 2 = Degraded 4 = Not present 5 = Single Port on Fibre The enclosure number, bay number, and rack number where the Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1], attribute.value.u32[2] fields, respectively. The attribute.type field contains value 1. The rack number in the attribute.value.u32[2] field will not contain a valid value until a future release.

2355 88030933 2 9 33 Storage Cell: %1 Event ID: %2 Description: The Derived Unit identified in the handle field was created. The add_handle field contains the identity of the Storage System Virtual Disk that is associated with that Derived Unit. The attribute.value.obj field contains the identity of the Virtual Disk associated with that Derived Unit.

2356 88030934 2 9 34 Storage Cell: %1 Event ID: %2 Description: The internal Logical Disk associated with the Virtual Disk identified in the handle field was created. The add_handle field contains the identity of the Disk Group where this internal Logical Disk was created. The attribute.value.u64[0] field contains the size (in blocks) of the internal Logical Disk. The attribute.value.u32[2] field contains the redundancy type of the internal Logical Disk. The attribute.type field contains the value 1. The values that may be found in the attribute.value.u32[2] field are as follows: 1 = Vraid0 2 = Vraid1 3 = Vraid5.

2357 88030935 2 9 35 Storage Cell: %1 Event ID: %2 Description: The Disk Group identified in the handle field was created. The attribute.value.u32[0] field contains the number of physical disk drives within the Disk Group. The attribute.type field contains the value 1.

2358 88030936 2 9 36 Storage Cell: %1 Event ID: %2 Description: The Physical Disk Drive identified in the handle field was discovered. The enclosure number and bay number where the Physical Disk Drive is located are contained in the attribute.value.u32[0] and attribute.value.u32[1] fields, respectively. The attribute.type field contains the value 1.

2359 88030937 2 9 37 Storage Cell: %1 Event ID: %2 Description: The Presented Unit identified in the handle field was created. The add_handle field contains the identity of the Storage System Virtual Disk that is associated with the Presented Unit. This Presented Unit is associated with the Virtual Disk identified in the attribute.value.obj.handle field. The add_handle2 field contains the associated Storage System Host path, and add_data[0] and add_data[1] contains the host LUN number.

2360 88030938 2 9 38 Storage Cell: %1 Event ID: %2 Description: The Storage System Host path identified in the handle field was created.

2361 88030939 2 9 39 Storage Cell: %1 Event ID: %2 Description: The Storage System Virtual Disk identified in the handle field was created.

2362 8803093a 2 9 3a Storage Cell: %1 Event ID: %2 Description: The Volume identified in the handle field was created. The add_handle field contains the identity of the Physical Disk Drive that is associated with the Volume. The attribute.value.u64[0] field contains the Fibre Channel node name of the associated Physical Disk Drive. The enclosure and bay number where the associated Physical Disk Drive is located are contained in the attribute.value.u32[2] and attribute.value.u32[3] fields respectively. The attribute.type field contains the value of 1.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 81: c00287657

Command View EVA event codes

81Event code definitions application notes

2363 8803093b 2 9 3b Storage Cell: %1 Event ID: %2 Description: The Derived Unit identified in the handle field was deleted. The add_handle field contains the identity of the Storage System Virtual Disk that was associated with the Derived Unit. This Derived Unit is associated with the Virtual Disk identified in the attribute.value.obj.handle field.

2364 8803093c 2 9 3c Storage Cell: %1 Event ID: %2 Description: The internal Logical Disk associated with the Virtual Disk identified in the handle field was deleted.

2365 8803093d 2 9 3d Storage Cell: %1 Event ID: %2 Description: The Disk Group identified in the handle field was deleted.

2366 8803093e 6 9 3e Storage Cell: %1 Event ID: %2 Description: The Physical Disk Drive identified in the handle field has disappeared. The enclosure number and bay number where the Physical Disk Drive was located are contained in the attribute.value.u32[0] and attribute.value.u32[1] fields, respectively. The attribute.type field contains the value 1.

2367 8803093f 2 9 3f Storage Cell: %1 Event ID: %2 Description: The Presented Unit identified in the handle field was deleted. The add_handle field contains the identity of the Storage System Virtual Disk that was associated with the Presented Unit. This Presented Unit is associated with the Virtual Disk identified in the attribute.value.obj.handle field.

2368 88030940 2 9 40 Storage Cell: %1 Event ID: %2 Description: The Storage System Host path identified in the handle field was deleted.

2369 88030941 2 9 41 Storage Cell: %1 Event ID: %2 Description: The Storage System Virtual Disk identified in the handle field was deleted. The Storage System Virtual Disk is associated with the Virtual Disk identified in the add_handle field.

2370 88030942 6 9 42 Storage Cell: %1 Event ID: %2 Description: The Snapshot Logical Disk identified in the handle field has been marked inoperative due to the Disk Group being out of space for additional storage allocation. The add_handle field contains the handle of the associated Disk Group object.

2371 88030943 2 9 43 Storage Cell: %1 Event ID: %2 Description: The HSV controller identified in the handle field has joined the Storage System. If the handle field is zero, the HSV controller identity could not be obtained due to an unexpected state transition.

2372 88030944 6 9 44 Storage Cell: %1 Event ID: %2 Description: An HSV controller has left the Storage System. The HSV controller is identified in the handle field. If the handle field is zero, the HSV controller identity could not be obtained due to an unexpected state transition.

2373 88030945 2 9 45 Storage Cell: %1 Event ID: %2 Description: A Storage System has been deleted by an HSV controller. The Storage System is identified in the handle field. The HSV controller is identified in the add_handle field. If the handle field or add_handle field is zero, the corresponding identity could not be obtained due to an unexpected state transition.

2374 88030946 2 9 46 Storage Cell: %1 Event ID: %2 Description: The Data Replication Group identified in the handle field was created.

2375 88030947 2 9 47 Storage Cell: %1 Event ID: %2 Description: The Data Replication Group identified in the handle field was deleted.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 82: c00287657

Command View EVA event codes

82 Event code definitions application notes

2376 88030948 2 9 48 Storage Cell: %1 Event ID: %2 Description: The internal Logical Disk associated with the Snapshot Virtual Disk identified in the handle field was created. The add_handle field contains the identity of the Disk Group where this internal Logical Disk was created. The attribute.value.u64[0] field contains the size (in blocks) of the reserved capacity of the internal Logical Disk. The attribute.value.u32[2] field contains the redundancy type of the internal Logical Disk. The attribute.value.u32[3] field contains the noid of the associated successor internal Logical Disk. The attribute.type field contains the value 1. The values that may be found in the attribute.value.u32[2] field are as follows: 1 = Vraid0 2 = Vraid1 3 = Vraid5.

2377 88030949 2 9 49 Storage Cell: %1 Event ID: %2 Description: The internal Logical Disk associated with the Copy of the Virtual Disk identified in the handle field was created. The add_handle field contains the identity of the Disk Group where this internal Logical Disk was created. The attribute.value.u64[0] field contains the size (in blocks) of the reserved capacity of the target Virtual Disk. The attribute.value.u32[2] field contains the redundancy type of the internal Logical Disk. The attribute.value.u32[3] field contains the noid of the associated successor internal Logical Disk. The attribute.type field contains the value 1. The values that may be found in the attribute.value.u32[2] field are as follows: 1 = Vraid0 2 = Vraid1 3 = Vraid5.

2405 88030965 2 9 65 Storage Cell: %1 Event ID: %2 Description: The Host Operating System mode of the Storage System Host identified in the handle field has changed. The old_attr.type and new_attr.type fields contain the value 1. The old_attr.value.u32[0] field contains the old Host Operating System mode. The new_attr.value.u32[0] field contains the new Host Operating System mode. The values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: 0 = Unknown 1 = User defined 2 = Unused 3 = WINNT with SecurePath 4 = VMS 5 = TRU64 UNIX 6 = Sun UNIX 7 = NetWare 8 = HP 9 = IBM 10 = LINUX 11 = SCO UNIX.

2406 88030966 2 9 66 Storage Cell: %1 Event ID: %2 Description: Time was set on the Storage System identified in the handle field.

2407 88030967 2 9 67 Storage Cell: %1 Event ID: %2 Description: The LUN of the Presented Unit identified in the handle field has changed. The old_attr.type field and the new_attr.type fields contain the value 1. The old_attr.value.u32[0..1] fields contain the value of the old LUN. The new_attr.value.u32[0..1] fields contain the value of the new LUN. The secondary_id field contains the noid portion of the handle for the Storage System Virtual Disk associated with the Presented Unit. This Presented Unit is associated with the Virtual Disk identified in the add_handle field.

2408 88030968 2 9 68 Storage Cell: %1 Event ID: %2 Description: The Device Addition Policy of the Storage System identified in the handle field has changed. The old_attr.type field and the new_attr.type fields contain the value 1. The old_attr.value.u32[0] field contains the old Device Addition Policy. The new_attr.value.u32[0] field contains the new Device Addition Policy. The policy values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: 1 = Manual policy 2 = Automatic policy.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 83: c00287657

Command View EVA event codes

83Event code definitions application notes

2409 88030969 2 9 69 Storage Cell: %1 Event ID: %2 Description: The Quiescent state of the Storage System Virtual Disk identified in the handle field has changed. The old_attr.type field and the new_attr.type fields contain the value 1. The old_attr.value.u32[0] field contains the old Quiescent state. The new_attr.value.u32[0] field contains the new Quiescent state. The state values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: 0 = Not quiescent 1 = Quiescent This Storage System Virtual Disk is associated with the Virtual Disk identified in the add_handle field.

2410 8803096a 2 9 6a Storage Cell: %1 Event ID: %2 Description: The Enabled/Disabled state of the Storage System Virtual Disk identified in the handle field has changed. The old_attr.type field and the new_attr.type fields contain the value 1. The old_attr.value.u32[0] field contains the old Enabled/Disabled state. The new_attr.value.u32[0] field contains the new Enabled/Disabled state. The state values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: 1 = Disabled 2 = Enabled This Storage System Virtual Disk is associated with the Virtual Disk identified in the add_handle field.

2411 8803096b 2 9 6b Storage Cell: %1 Event ID: %2 Description: The Cache Policy of the Storage System Virtual Disk identified in the handle field has changed. The old_attr.type field and the new_attr.type fields contain the value 1. The old_attr.value.u32[0] field contains the old Write Cache Policy. The new_attr.value.u32[0] field contains the new Write Cache Policy. The policy values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: 1 = Writethrough 2 = Writeback The old_attr.value.u32[1] field contains the old Read Cache Policy. The new_attr.value.u32[1] field contains the new Read Cache Policy. The policy values that may be found in the old_attr.value.u32[1] and new_attr.value.u32[1] fields are as follows: 1 = Read cache on 2 = Read cache off The old_attr.value.u32[2] field contains the old Cache Mirroring Policy. The new_attr.value.u32[2] field contains the new Cache Mirroring Policy. The policy values that may be found in the old_attr.value.u32[2] and new_attr.value.u32[2] fields are as follows: 1 = Mirror 2 = No mirror This Storage System Virtual Disk is associated with the Virtual Disk identified in the add_handle field.

2412 8803096c 2 9 6c Storage Cell: %1 Event ID: %2 Description: The Usage state of the Volume identified in the handle field has changed. The old_attr.value.u32[0] field contains the old Usage state. The new_attr.value.u32[0] field contains the new Usage state. The Usage state values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: 1 = Disk Group 2 = Reserved 4 - 20 = temporary usage reserved for drive code load This Volume is associated with the Disk Group identified in the add_handle field, if either the old Usage state or the new Usage state is 1. The secondary_id field contains the internal identification of the volume’s Redundant Storage Set.

2413 8803096d 2 9 6d Storage Cell: %1 Event ID: %2 Description: The Disk Failure Protection Level of the Disk Group identified in the handle field has changed. The old_attr.type and new_attr.type fields contain the value 1. The old_attr.value.u32[0] field contains the old number of physical disk drives available for use. The new_attr.value.u32[0] field contains the new number of physical disk drives available for use.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 84: c00287657

Command View EVA event codes

84 Event code definitions application notes

2414 8803096e 2 9 6e Storage Cell: %1 Event ID: %2 Description: The Write Protected state of the Derived Unit identified in the handle field has changed. This Derived Unit is associated with the Virtual Disk identified in the add_handle field. The secondary_id field contains the noid portion of the handle for the Storage System Virtual Disk associated with the Derived Unit. The old_attr.type field and the new_attr.type fields contain the value 1. The old_attr.value.u32[0] field contains the old Write Protected state. The new_attr.value.u32[0] field contains the new Write Protected state. The Write Protected state values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: 0 = Write protect off 1 = Write protect on This Derived Unit is associated with the Virtual Disk identified in the add_handle field.

2416 88030970 3 9 70 Storage Cell: %1 Event ID: %2 Description: The Physical Disk Drive identified in the handle field has experienced numerous communication failures on a particular Fibre Channel port identified in old_attr.value.u32[0] field. The enclosure number, bay number, and rack number where the Physical Disk Drive is located are contained in the old_attr.value.u32[0], old_attr.value.u32[1], old_attr.value.u32[2] fields, respectively. The old_attr.type field contains value 1. The new_attr.value.str field contains the cerp_id of the Fibre Channel port. The new_attr.type field contains value 4.

2417 88030971 2 9 71 Storage Cell: %1 Event ID: %2 Description: The HSV controller identified in the handle field received a request to shutdown. The old_attr.type field and the new_attr.type fields contain the value 1. The old_attr.value.u32[0] field indicates the type of restart that was requested as follows: 0 = None -- no restart 1 = Regular -- full restart, host system connectivity is lost until the controller returns to normal operation 2 = Fast -- resynchronization, restart of the controller in a manner that has little or no impact on host system connectivity The old_attr.value.u32[1] field indicates whether the other HSV controller of the pair was requested to remain operational or to also shutdown as follows: 0 = Remain operational 1 = Coupled shutdown The old_attr.value.u32[2] field indicates whether the HSV controller was requested to remain in the power on state or power itself off as follows: 0 = Remain in the power on state 1 = Power itself off The old_attr.value.u32[3] field value indicates whether the Physical Disk Drive enclosure(s) was requested to remain in the power on state or to be powered off as follows: 0 = Remain in the power on state 1 = Powered off The old_attr.value.u32[4] field value indicates whether the battery assemblies located within the HSV controller were requested to be enabled or disabled as follows: 0 = Enabled 1 = Disabled The old_attr.value.u32[5] field contains the number of seconds the shutdown operation was requested to be delayed.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 85: c00287657

Command View EVA event codes

85Event code definitions application notes

2418 88030972 2 9 72 Storage Cell: %1 Event ID: %2 Description: The HSV controller identified in the handle field has completed its shutdown preparations. The old_attr.type field and the new_attr.type fields contain the value 1. The old_attr.value.u32[0] field value indicates the result of the HSV controller Cache Memory shutdown operation as follows: 1 = Success 2 = Failure 3 = Not applicable The old_attr.value.u32[1] field contains the internal Storage System Management Interface cache shutdown status code. The old_attr.value.u32[2] field value indicates the result of the Physical Disk Drive enclosure(s) power off operation as follows: 1 = Success 2 = Failure 3 = Not applicable The old_attr.value.u32[3] field contains the internal Storage System Management Interface Physical Disk Drive enclosure(s) power off status code. The old_attr.value.u32[4] field value indicates the result of the battery assemblies disable operation as follows: 1 = Success 2 = Failure 3 = Not applicable The old_attr.value.u32[5] field value indicates the battery assemblies disable operation failure mode as follows: 0 = No failure indicated. 1 = Failed only on the HSV controller identified in the handle field. 2 = Failed only on the other HSV controller of the pair. 3 = Failed on both HSV controllers.

2419 88030973 2 9 73 Storage Cell: %1 Event ID: %2 Description: The Failsafe state of the Data Replication Group identified in the handle field has changed. The old_attr.value.u32[0] field contains the old Failsafe state. The new_attr.value.u32[0] field contains the new Failsafe state. The Failsafe state values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: 1 = Failsafe Disabled 2 = Failsafe Enabled.

2420 88030974 2 9 74 Storage Cell: %1 Event ID: %2 Description: The Mode of the Data Replication Group identified in the handle field has changed. The old_attr.value.u32[0] field contains the old Mode. The new_attr.value.u32[0] field contains the new Mode. The Mode values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: 0 = Normal Active Source 1 = Normal Active Destination 2 = Active/Active (Master) 3 = Active/Active (Non-Master).

2421 88030975 2 9 75 Storage Cell: %1 Event ID: %2 Description: The Operational state of a Data Replication Group has changed to Synchronous or Asynchronous. The old_attr.value.u32[0] field contains the old Operation state. The new_attr.value.u32[0] field contains the new Operation state. The Operation state values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: 1 = Synchronous 2 = Asynchronous.

2422 88030976 2 9 76 Storage Cell: %1 Event ID: %2 Description: The Read Only attribute of the Data Replication Group identified in the handle field has changed. The old_attr.value.u32[0] field contains the old Read Only attribute. The new_attr.value.u32[0] field contains the new Read Only attribute. The Read Only attribute values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: 0 = Data Replication Destination Storage System Virtual Disk disabled for read access. 1 = Data Replication Destination Storage System Virtual Disk enabled for read access.

2423 88030977 2 9 77 Storage Cell: %1 Event ID: %2 Description: A Data Replication Group failover has occurred. The handle field contains the identity of the Data Replication Group. The old_attr.value.u32[0] field contains the old Role. The new_attr.value.u32[0] field contains the new Role. 0 = Normal Active Source 1 = Normal Active Destination 2 = Active/Active (Master) 3 = Active/Active (Non-Master).

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 86: c00287657

Command View EVA event codes

86 Event code definitions application notes

2424 88030978 2 9 78 Storage Cell: %1 Event ID: %2 Description: A Data Replication Group has been suspended or resumed. The handle field contains the identity of the Data Replication Group. The old_attr.value.u32[0] field contains the old Suspend state. The new_attr.value.u32[0] field contains the new Suspend state. The Suspend state values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: 1 = Connection between the Data Replication Source and Data Replication Destination is active. 2 = Connection between the Data Replication Source and Data Replication Destination is inactive.

2425 88030979 2 9 79 Storage Cell: %1 Event ID: %2 Description: A Storage System Virtual Disk was added to a Data Replication Group. The Storage System Virtual Disk is identified in the add_handle field. The Data Replication Group is identified in the handle field.

2426 8803097a 2 9 7a Storage Cell: %1 Event ID: %2 Description: A Storage System Virtual Disk was removed from a Data Replication Group. The Storage System Virtual Disk is identified in the add_handle field. The Data Replication Group is identified in the handle field.

2504 880309c8 6 9 c8 Storage Cell: %1 Event ID: %2 Description: The Data Availability state of the internal Logical Disk associated with the Virtual Disk identified in the handle field has transitioned to the DATA LOST state. The value.ul1 field contains the new state: 1 (DATA LOST). The value.ul2 field contains the old state: 0 (NORMAL).

2505 880309c9 6 9 c9 Storage Cell: %1 Event ID: %2 Description: The state of the Disk Group identified in the handle field has transitioned to an INOPERATIVE state. The value.ul1 field contains the new Disk Group state. The value.ul2 field contains the old Disk Group state. The state values that may be found in the value.ul1 and value.ul2 fields are as follows: 1 = Normal 2 = Disk Group with no redundancy is inoperative 3 = Disk Group with parity redundancy is inoperative 4 = Disk Group with mirrored redundancy is inoperative 5 = Disk Group with no redundancy is inoperative, marked for re-use 6 = Disk Group with parity redundancy is inoperative, marked for re-use 7 = Disk Group with mirrored redundancy is inoperative, marked for re-use.

2506 880309ca 6 9 ca Storage Cell: %1 Event ID: %2 Description: The state of the internal Logical Disk associated with the Virtual Disk identified in the handle field has transitioned to the FAILED state. The value.ul1 field contains the new state: 5 (FAILED). The value.ul2 field contains the old state. The state values that may be found in the value.ul2 field are as follows: 1 = Normal 2 = Replacement delay in progress 3 = Redundancy lost, restore in progress 4 = Redundancy lost, restore stalled 6 = Creation in progress 7 = Snapshot is inoperative due to lack of snapshot space 8 = Deletion in progress 9 = Capacity change in progress 10 = Inoperative due to data lost 11 = Capacity reservation in progress 12 = Capacity unreservation in progress.

2507 880309cb 6 9 cb Storage Cell: %1 Event ID: %2 Description: The state of the internal Logical Disk associated with the Virtual Disk identified in the handle field has transitioned to the SNAPSHOT OVERCOMMIT state. The value.ul1 field contains the new state: 7 (SNAPSHOT OVERCOMMIT). The value.ul2 field contains the old state. The state values that may be found in the value.ul2 field are as follows: 1 = Normal 2 = Replacement delay in progress 3 = Redundancy lost, restore in progress 4 = Redundancy lost, restore stalled 5 = Failed 6 = Creation in progress 8 = Deletion in progress 9 = Capacity change in progress 10 = Inoperative due to device data lost 11 = Capacity reservation in progress 12 = Capacity unreservation in progress.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 87: c00287657

Command View EVA event codes

87Event code definitions application notes

2508 880309cc 6 9 cc Storage Cell: %1 Event ID: %2 Description: The state of the internal Logical Disk associated with the Virtual Disk identified in the handle field has transitioned to the DEVICE DATA LOST state. The value.ul1 field contains the new state: 10 (DEVICE DATA LOST). The value.ul2 field contains the old state. The state values that may be found in the value.ul2 field are as follows: 1 = Normal 2 = Replacement delay in progress 3 = Redundancy lost restore, in progress 4 = Redundancy lost restore, stalled 5 = Failed 6 = Creation in progress 7 = Snapshot is inoperative due to lack of snapshot space 8 = Deletion in progress 9 = Capacity change in progress 11 = Capacity reservation in progress 12 = Capacity unreservation in progress.

2509 880309cd 6 9 cd Storage Cell: %1 Event ID: %2 Description: The state of the Fibre Channel port identified in the attribute.value.str field and located on the rear panel of the HSV controller identified in the handle field has transitioned to the FAILED state. The attribute.type field contains the value 4. The value.ul1 field contains the new state: 2 (FAILED). The value.ul2 field contains the old state: 1 (NORMAL). Note that the HSV controller’s internal identity of the affected Fibre Channel port is contained in the secondary_id field.

2510 880309ce 2 9 ce Storage Cell: %1 Event ID: %2 Description: The state of the Disk Group identified in the handle field has transitioned to an INOPERATIVE MARKED state. The value.ul1 field contains the new Disk Group state. The value.ul2 field contains the old Disk Group state. The state values that may be found in the value.ul1 and value.ul2 fields are as follows: 1 = Normal 2 = Disk Group with no redundancy is inoperative 3 = Disk Group with parity redundancy is inoperative 4 = Disk Group with mirrored redundancy is inoperative 5 = Disk Group with no redundancy is inoperative, marked for re-use 6 = Disk Group with parity redundancy is inoperative, marked for re-use 7 = Disk Group with mirrored redundancy is inoperative, marked for re-use.

2511 880309cf 3 9 cf Storage Cell: %1 Event ID: %2 Description: The state of the Physical Disk Drive identified in the handle field has transitioned to the NOT PRESENT state. The value.ul1 field contains the new state: 4 (NOT PRESENT). The value.ul2 field contains the old state. The state values that may be in the value.ul2 field are as follows: 1 = Normal 2 = Degraded 3 = Failed 5 = Single Port on Fibre The enclosure number, bay number, and rack number where the Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1], attribute.value.u32[2] fields, respectively. The attribute.type field contains value 1. The rack number in the attribute.value.u32[2] field will not contain a valid value until a future release.

2512 880309d0 2 9 d0 Storage Cell: %1 Event ID: %2 Description: The HSV controller identified in the handle field no longer needs attention.

2513 880309d1 6 9 d1 Storage Cell: %1 Event ID: %2 Description: The HSV controller identified in the handle field needs attention.

2514 880309d2 6 9 d2 Storage Cell: %1 Event ID: %2 Description: The Blower Present flag for the ‘1’ blower assembly located within the HSV controller identified in the handle field has transitioned from the PRESENT to NOT PRESENT state indicating that the blower has been removed. The secondary_id field contains the ‘1’ blower assembly internal identifier value: 1. The value.ul1 field contains the new state of the Blower Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old state of the Blower Present flag: 1 (PRESENT).

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 88: c00287657

Command View EVA event codes

88 Event code definitions application notes

2515 880309d3 6 9 d3 Storage Cell: %1 Event ID: %2 Description: At least one Virtual Disk associated with the Data Replication Group identified in the handle field has transitioned to the INOPERATIVE state. The remaining Virtual Disks associated with this Data Replication Group have been forced INOPERATIVE. The value.ul1 field contains the new Data Replication Group member state: 2 (INOPERATIVE). The value.ul2 field contains the old Data Replication Group member state: 1 (OPERATIVE).

2516 880309d4 2 9 d4 Storage Cell: %1 Event ID: %2 Description: All the Virtual Disks associated with the Data Replication Group identified in the handle field have transitioned to the OPERATIVE state. The value.ul1 field contains the new Data Replication Group member state: 1 (OPERATIVE). The value.ul2 field contains the old Data Replication Group member state: 2 (INOPERATIVE).

2517 880309d5 2 9 d5 Storage Cell: %1 Event ID: %2 Description: The state of the Physical Disk Drive identified in the handle field has transitioned to the Single Port on Fibre state. The value.ul1 field contains the new state: 5 (SINGLE PORT ON FIBRE). The value.ul2 field contains the old state. The state values that may be in the value.ul2 field are as follows: 1 = Normal 2 = Degraded 3 = Failed 4 = Not Present.

2816 88030b00 2 b 0 Storage Cell: %1 Event ID: %2 Description: The HSV controller identified by the node_name field has begun a resynchronization operation (i.e., a restart of the controllers in a manner that has little or no impact on host system connectivity). The information.pc field contains the program counter of resynchronization operation initiator. The information.flags field contains reboot flags value. The information.code field contains the resynchronization operation event code value.

3072 88030c00 2 c 0 Storage Cell: %1 Event ID: %2 Description: The specified Destination Virtual Disk has successfully completed a Full Copy. The following fields are not valid: status, blocks, vda.

3073 88030c01 6 c 1 Storage Cell: %1 Event ID: %2 Description: The specified Source Virtual Disk has transitioned to the Logging state because the alternate Storage System is not accessible or the Data Replication Group is suspended. The following fields are not valid: status, blocks, vda, port, cerp_id, side.

3074 88030c02 6 c 2 Storage Cell: %1 Event ID: %2 Description: The specified Source Virtual Disk has transitioned to the Logging state because the Destination Virtual Disk is not accessible. The following fields are not valid: status, blocks, vda, port, cerp_id, side.

3075 88030c03 2 c 3 Storage Cell: %1 Event ID: %2 Description: The specified Destination Virtual Disk has transitioned to the Merging state, because the alternate Storage System or Destination Virtual Disk is now accessible or resumed. The following fields are not valid: status, blocks, vda.

3076 88030c04 6 c 4 Storage Cell: %1 Event ID: %2 Description: A Data Replication Group has entered the Failsafe Locked state due to an inaccessible or inoperative destination. Either the Destination Virtual Disk is not accessible or a Virtual Disk in the Data Replication Group is inoperative. The following fields are not valid: status, blocks, vda, port, cerp_id, side.

3077 88030c05 6 c 5 Storage Cell: %1 Event ID: %2 Description: A Data Replication Group has entered the Failsafe Locked state due to an inoperative source. Either the Source Virtual Disk is not accessible or a Virtual Disk in the Data Replication Group is inoperative. The following fields are not valid: status, blocks, vda, port, cerp_id, side.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 89: c00287657

Command View EVA event codes

89Event code definitions application notes

3078 88030c06 6 c 6 Storage Cell: %1 Event ID: %2 Description: An unrecoverable read error occurred on the specified Source Virtual Disk during the Full Copy. The Virtual Disk address specified in the vda field indicates the first block in error. The Full Copy was terminated.

3079 88030c07 6 c 7 Storage Cell: %1 Event ID: %2 Description: A Full Copy terminated prior to completion. A remote copy error occurred due to an inaccessible alternate Storage System. The Virtual Disk address specified in the vda field indicates the first block in error. The Full Copy will continue when the Data Replication Destination is restored.

3080 88030c08 6 c 8 Storage Cell: %1 Event ID: %2 Description: A Full Copy terminated prior to completion. A remote copy error occurred due to an inaccessible Destination Virtual Disk. The Virtual Disk address specified in the vda field indicates the first block in error. The Full Copy will continue when the Data Replication Destination is restored.

3081 88030c09 3 c 9 Storage Cell: %1 Event ID: %2 Description: A Data Replication Log has been reset due to insufficient Disk Group capacity. The Data Replication Destination has been marked for a Full Copy. The following fields are not valid: status, blocks, vda, port, cerp_id, side.

3082 88030c0a 2 c a Storage Cell: %1 Event ID: %2 Description: A Data Replication Log has been reset due to a Data Replication Group failover. The following fields are not valid: status, blocks, vda.

3084 88030c0c 2 c c Storage Cell: %1 Event ID: %2 Description: A Destination Data Replication Group has successfully completed a Merge. The following fields are not valid: status, blocks, vda.

3087 88030c0f 2 c f Storage Cell: %1 Event ID: %2 Description: A Data Replication Group is no longer in a Failsafe Locked state. The following fields are not valid: status, blocks, vda, port, cerp_id, side.

3088 88030c10 2 c 10 Storage Cell: %1 Event ID: %2 Description: A Destination Data Replication Group has been marked for a Full Copy. The following fields are not valid: status, blocks, vda.

3089 88030c11 2 c 11 Storage Cell: %1 Event ID: %2 Description: A Storage System has discovered that a Data Replication Group failover has taken place. This Virtual Disk is transitioning from a Data Replication Source role to a Data Replication Destination role. The following fields are not valid: status, blocks, vda.

3090 88030c12 2 c 12 Storage Cell: %1 Event ID: %2 Description: This Data Replication Group is transitioning from a Data Replication Destination role to a Data Replication Source role. The following fields are not valid: status, blocks, vda.

3092 88030c14 6 c 14 Storage Cell: %1 Event ID: %2 Description: The specified destination DRM group was not found. The destination group appears to have been deleted by the user after a site failover, therefore this dangling DRM source group should likewise be deleted.

3093 88030c15 2 c 15 Storage Cell: %1 Event ID: %2 Description: The Data Replication Path between this Site and the Alternate Site has closed, possibly due to a connection failure between the specified host port and the Alternate Site. The following fields are not valid: group_name_uuid, group_uuid, source_scvd_uuid, status, block, vda.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 90: c00287657

Command View EVA event codes

90 Event code definitions application notes

3328 88030d00 6 d 0 Storage Cell: %1 Event ID: %2 Description: Unrecognized event reported by a Drive Enclosure Environmental Monitoring Unit. The handle field contains the WWN of the shelf containing the Drive Enclosure Environmental Monitoring Unit. The event was reported by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the rack_num field will not be valid until a future release. The content of the alarm_error_code field could not be translated into a known event. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 91: c00287657

Command View EVA event codes

91Event code definitions application notes

3329 88030d01 6 d 1 Storage Cell: %1 Event ID: %2 Description: A physical disk drive that is not Fibre Channel compatible or cannot operate at the link rate established by the drive enclosure I/O modules was detected. The handle field contains the WWN of the shelf containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the rack_num field will not be valid until a future release. This problem was detected during spin up of the physical disk drive installed in the drive enclosure bay identified in the alarm_error_code.field.en field. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 92: c00287657

Command View EVA event codes

92 Event code definitions application notes

3330 88030d02 3 d 2 Storage Cell: %1 Event ID: %2 Description: A physical disk drive is improperly installed or missing. This could affect the drive enclosure air flow and cause an over temperature condition. The handle field contains the WWN of the shelf containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the rack_num field will not be valid until a future release. The affected drive enclosure bay is identified in the alarm_error_code.field.en field. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 93: c00287657

Command View EVA event codes

93Event code definitions application notes

3331 88030d03 3 d 3 Storage Cell: %1 Event ID: %2 Description: A physical disk drive was removed while software-activated drive locking was enabled on a drive enclosure that does not support drive locking. The handle field contains the WWN of the shelf containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the rack_num field will not be valid until a future release. The affected drive enclosure bay is identified in the alarm_error_code.field.en field. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 94: c00287657

Command View EVA event codes

94 Event code definitions application notes

3332 88030d04 6 d 4 Storage Cell: %1 Event ID: %2 Description: A physical disk drive that is capable of operating at the loop link rate established by the drive enclosure I/O module was found to be running at a different rate. The handle field contains the WWN of the shelf containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the rack_num field will not be valid until a future release. The affected physical disk drive is installed in the drive enclosure bay identified in the alarm_error_code.field.en field. The Fibre Channel loop on which the problem was detected is identified by the content of the alarm_error_code.field.ec field as follows: 4 = loop A 5 = loop B The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 95: c00287657

Command View EVA event codes

95Event code definitions application notes

3379 88030d33 3 d 33 Storage Cell: %1 Event ID: %2 Description: The AC input to a drive enclosure power supply has been lost. This makes the remaining power supply a single point of failure. The handle field contains the WWN of the shelf containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the rack_num field will not be valid until a future release. The location of the affected power supply (1 or 2) is identified in the alarm_error_code.field.en field. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 96: c00287657

Command View EVA event codes

96 Event code definitions application notes

3380 88030d34 6 d 34 Storage Cell: %1 Event ID: %2 Description: A drive enclosure power supply is improperly installed or missing. This could affect the drive enclosure air flow and cause an over temperature condition. The operational power supply will automatically shut down after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply shuts down, whichever occurs first. The handle field contains the WWN of the shelf containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the rack_num field will not be valid until a future release. The location of the affected power supply (1 or 2) is identified in the alarm_error_code.field.en field. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 97: c00287657

Command View EVA event codes

97Event code definitions application notes

3381 88030d35 6 d 35 Storage Cell: %1 Event ID: %2 Description: A drive enclosure power supply component has failed. The handle field contains the WWN of the shelf containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the rack_num field will not be valid until a future release. The location of the affected power supply (1 or 2) is identified in the alarm_error_code.field.en field. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 98: c00287657

Command View EVA event codes

98 Event code definitions application notes

3399 88030d47 6 d 47 Storage Cell: %1 Event ID: %2 Description: A drive enclosure blower is not operating properly. This could affect the drive enclosure air flow and cause an over temperature condition. The handle field contains the WWN of the shelf containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the rack_num field will not be valid until a future release. The location of the affected blower (1 or 2) is identified in the alarm_error_code.field.en field. The cause of the improper operation is described by the content of the alarm_error_code.field.ec field as follows: 1 = The blower is operating at a speed that is outside of the Drive Enclosure Environmental Monitoring Unit specified range, possibly because of a bearing problem. 2 = The blower is operating at a speed that is significantly outside of the Drive Enclosure Environmental Monitoring Unit specified range, possibly because of a bearing problem. 3 = The blower has stopped. NOTE: The other blower (if operational) now operates at high speed and is a single point of failure. A single blower operating at high speed can provide sufficient air flow to cool an enclosure and the elements for up to 100 hours. However, operating an enclosure at temperatures approaching an overheating threshold can damage elements and may reduce the MTBF of a specific element. Hewlett-Packard therefore recommends immediate replacement of the defective blower. 4 = The power supply reported an internal blower error. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 99: c00287657

Command View EVA event codes

99Event code definitions application notes

3403 88030d4b 6 d 4b Storage Cell: %1 Event ID: %2 Description: A drive enclosure blower is improperly installed or missing. This affects the drive enclosure air flow and can cause an over temperature condition. The handle field contains the WWN of the shelf containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the rack_num field will not be valid until a future release. The location of the affected blower (1 or 2) is identified in the alarm_error_code.field.en field. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 100: c00287657

Command View EVA event codes

100 Event code definitions application notes

3404 88030d4c 6 d 4c Storage Cell: %1 Event ID: %2 Description: Both drive enclosure blowers are missing. This severely affects the drive enclosure air flow and can cause an over temperature condition. The operational power supply(s) will automatically shut down after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. The handle field contains the WWN of the shelf containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the rack_num field will not be valid until a future release. Note that this event is preceded by a ‘drive enclosure blower is improperly installed or missing’ event that identifies the location of the first missing blower. The location of the second missing blower (1 or 2) is identified in the alarm_error_code.field.en field of this event. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 101: c00287657

Command View EVA event codes

101Event code definitions application notes

3419 88030d5b 3 d 5b Storage Cell: %1 Event ID: %2 Description: A drive enclosure temperature sensor out of range condition has been reported by one of the drive enclosure elements. The handle field contains the WWN of the shelf containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the rack_num field will not be valid until a future release. The location of the temperature sensor (1 through 11) is identified in the alarm_error_code.field.en field as follows: 1 = Power Supply 1 Exhaust 2 = Power Supply 2 Exhaust 3 = Drive Enclosure Environmental Monitoring Unit 4 = Drive Bay 1 5 = Drive Bay 2 6 = Drive Bay 3 7 = Drive Bay 4 8 = Drive Bay 5 9 = Drive Bay 6 A = Drive Bay 7 B = Drive Bay 8 C = Drive Bay 9 D = Drive Bay 10 E = Drive Bay 11 F = Drive Bay 12 10 = Drive Bay 13 11 = Drive Bay 14 The temperature sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows: 1 = The element temperature is approaching, but has not reached, the high temperature CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition and may reduce an element’s MTBF. 2 = The element temperature is above the high temperature CRITICAL threshold. Continued operation under these conditions may result in element failure. 3 = The element temperature is approaching, but has not reached, the low temperature CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition and may reduce an element’s MTBF. 4 = The element temperature has reached the low temperature CRITICAL threshold. Continued operation under these conditions may result in element failure. The actual temperature threshold values can be found in the HSV element manager GUI. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 102: c00287657

Command View EVA event codes

102 Event code definitions application notes

3423 88030d5f 6 d 5f Storage Cell: %1 Event ID: %2 Description: The average temperature of two of the three temperature sensor groups (i.e., Drive Enclosure Environmental Monitoring Unit, Disk Drives, and Power Supplies) exceeds the CRITICAL level. The operational power supply(s) will automatically shut down after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. The handle field contains the WWN of the shelf containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the rack_num field will not be valid until a future release. Note that in this case the content of the alarm_error_code.field.en field is undefined. The actual temperature threshold values can be found in the HSV element manager GUI. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 103: c00287657

Command View EVA event codes

103Event code definitions application notes

3439 88030d6f 3 d 6f Storage Cell: %1 Event ID: %2 Description: An internal Drive Enclosure Environmental Monitoring Unit error has occurred. The handle field contains the WWN of the shelf containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the rack_num field will not be valid until a future release. The alarm_error_code.field.en field contains the value 1 signifying that the Drive Enclosure Environmental Monitoring Unit is the affected element. The cause of the improper operation is described by the content of the alarm_error_code.field.ec field as follows: 1 = An internal Drive Enclosure Environmental Monitoring Unit clock error has occurred. 2 = The Inter-IC (I2C) bus is not processing data and the Drive Enclosure Environmental Monitoring Unit is unable to monitor or report the status of the elements or enclosures. 5 = A Backplane NVRAM error has occurred. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 104: c00287657

Command View EVA event codes

104 Event code definitions application notes

3441 88030d71 2 d 71 Storage Cell: %1 Event ID: %2 Description: An internal Drive Enclosure Environmental Monitoring Unit error has occurred. The handle field contains the WWN of the shelf containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the rack_num field will not be valid until a future release. The alarm_error_code.field.en field contains the value 1 signifying that the Drive Enclosure Environmental Monitoring Unit is the affected element. The cause of the improper operation is described by the content of the alarm_error_code.field.ec field as follows: 3 = A drive enclosure power supply was shut down. 16 = The Drive Enclosure Environmental Monitoring Unit ESI data has been corrupted. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 105: c00287657

Command View EVA event codes

105Event code definitions application notes

3442 88030d72 3 d 72 Storage Cell: %1 Event ID: %2 Description: A Drive Enclosure Environmental Monitoring Unit is unable to collect data for the SCSI-3 Enclosure Services (SES) page. The handle field contains the WWN of the shelf containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the rack_num field will not be valid until a future release. The alarm_error_code.field.en field contains the value 1 signifying that the Drive Enclosure Environmental Monitoring Unit is the affected element. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 106: c00287657

Command View EVA event codes

106 Event code definitions application notes

3454 88030d7e 3 d 7e Storage Cell: %1 Event ID: %2 Description: Invalid data was read from a Drive Enclosure Environmental Monitoring Unit NVRAM. The handle field contains the WWN of the shelf containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the rack_num field will not be valid until a future release. The alarm_error_code.field.en field contains the value 1 signifying that the Drive Enclosure Environmental Monitoring Unit is the affected element. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 107: c00287657

Command View EVA event codes

107Event code definitions application notes

3455 88030d7f 3 d 7f Storage Cell: %1 Event ID: %2 Description: An internal Drive Enclosure Environmental Monitoring Unit error has occurred. The handle field contains the WWN of the shelf containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the rack_num field will not be valid until a future release. The alarm_error_code.field.en field contains the value 1 signifying that the Drive Enclosure Environmental Monitoring Unit is the affected element. The cause of the improper operation is described by the content of the alarm_error_code.field.ec field as follows: 11 = The Drive Enclosure Environmental Monitoring Unit cannot write data to the NVRAM. 12 = The Drive Enclosure Environmental Monitoring Unit cannot read data from the NVRAM. 13 = The Field Programmable Gate Array (FPGA) that controls the ESI bus failed to load information required for Drive Enclosure Environmental Monitoring Unit operation. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 108: c00287657

Command View EVA event codes

108 Event code definitions application notes

3458 88030d82 3 d 82 Storage Cell: %1 Event ID: %2 Description: A drive enclosure’s address is incorrect or the enclosure has no address. The handle field contains the WWN of the shelf containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the rack_num field will not be valid until a future release. The alarm_error_code.field.en field contains the value 1 signifying that the Drive Enclosure Environmental Monitoring Unit is the affected element. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 109: c00287657

Command View EVA event codes

109Event code definitions application notes

3459 88030d83 6 d 83 Storage Cell: %1 Event ID: %2 Description: A Drive Enclosure Environmental Monitoring Unit has experienced a hardware failure. The handle field contains the WWN of the shelf containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the rack_num field will not be valid until a future release. The alarm_error_code.field.en field contains the value 1 signifying that the Drive Enclosure Environmental Monitoring Unit is the affected element. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release. The cause of the improper operation is described by the content of the alarm_error_code.field.ec field as follows: 15 = Drive Enclosure Environmental Monitoring Unit hardware failure DP. 18 = Drive Enclosure Environmental Monitoring Unit hardware failed BT. 19 = Drive Enclosure Environmental Monitoring Unit ESI driver failure.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 110: c00287657

Command View EVA event codes

110 Event code definitions application notes

3461 88030d85 3 d 85 Storage Cell: %1 Event ID: %2 Description: A drive enclosure power supply failed to respond to a shut down command. The handle field contains the WWN of the shelf containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the rack_num field will not be valid until a future release. The alarm_error_code.field.en field contains the value 1 signifying that the Drive Enclosure Environmental Monitoring Unit is the affected element. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 111: c00287657

Command View EVA event codes

111Event code definitions application notes

3469 88030d8d 6 d 8d Storage Cell: %1 Event ID: %2 Description: A drive enclosure transceiver error has been detected. The handle field contains the WWN of the shelf containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the rack_num field will not be valid until a future release. The location of the transceiver (1 through 4) is identified in the alarm_error_code.field.en field as follows: 1 = Transceiver 01 2 = Transceiver 02 3 = Transceiver 03 4 = Transceiver 04 The transceiver error condition is described by the content of the alarm_error_code.field.ec field as follows: 1 = The transceivers on this link are not the same type or they are incompatible with the drive enclosure I/O module. This error prevents the controller from establishing a link with the enclosure drives and eliminates the enclosure dual-loop capability. 2 = The transceiver can no longer detect a data signal. This error prevents the controller from transferring data on a loop and eliminates the enclosure dual-loop capability. 3 = The system has detected an FC-AL bus fault involving a transceiver. This error prevents the controller from transferring data on a loop and eliminates the enclosure dual-loop capability. 4 = The transceiver that was previously in this location has been removed. 5 = The transceiver in the specified location has detected invalid Fibre Channel characters. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 112: c00287657

Command View EVA event codes

112 Event code definitions application notes

3489 88030da1 6 d a1 Storage Cell: %1 Event ID: %2 Description: A drive enclosure power supply voltage sensor out of range condition has been reported. The handle field contains the WWN of the shelf containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the rack_num field will not be valid until a future release. The location of the voltage sensor (1 through 4) is identified in the alarm_error_code.field.en field as follows: 1 = Power Supply 1 +5 VDC 2 = Power Supply 1 +12 VDC 3 = Power Supply 2 +5 VDC 4 = Power Supply 2 +12 VDC The voltage sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows: 1 = The element voltage is approaching, but has not reached, the high voltage CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. 2 = The element voltage is above the high voltage CRITICAL threshold. 3 = The element voltage is approaching, but has not reached, the low voltage CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. 4 = The element voltage has reached the low voltage CRITICAL threshold. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 113: c00287657

Command View EVA event codes

113Event code definitions application notes

3509 88030db5 6 d b5 Storage Cell: %1 Event ID: %2 Description: A drive enclosure power supply current sensor out of range condition has been reported. The handle field contains the WWN of the shelf containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the rack_num field will not be valid until a future release. The location of the current sensor (1 through 4) is identified in the alarm_error_code.field.en field as follows: 1 = Power Supply 1 +5 VDC 2 = Power Supply 1 +12 VDC 3 = Power Supply 2 +5 VDC 4 = Power Supply 2 +12 VDC The current sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows: 1 = The element current is approaching, but has not reached, the high current CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. 2 = The element current is above the high current CRITICAL threshold. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99,the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 114: c00287657

Command View EVA event codes

114 Event code definitions application notes

3544 88030dd8 3 d d8 Storage Cell: %1 Event ID: %2 Description: A drive enclosure backplane invalid NVRAM read error has occurred. The handle field contains the WWN of the shelf containing the Drive Enclosure Environmental Monitoring Unit.This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the rack_num field will not be valid until a future release. The alarm_error_code.field.en field contains the value 1 signifying that the drive enclosure is the affected element. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 115: c00287657

Command View EVA event codes

115Event code definitions application notes

3545 88030dd9 6 d d9 Storage Cell: %1 Event ID: %2 Description: A drive enclosure backplane error has occurred. The handle field contains the WWN of the shelf containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the rack_num field will not be valid until a future release. The alarm_error_code.field.en field contains the value 1 signifying that the drive enclosure is the affected element. The cause of the improper operation is described by the content of the alarm_error_code.field.ec field as follows: 11 = Unable to write data to the NVRAM. This problem prevents communication between elements in the enclosure. 12 = Unable to read data from the NVRAM. This problem prevents communication between elements in the enclosure. 13 = NVRAM has not been initialized properly. This is a manufacturing error. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 116: c00287657

Command View EVA event codes

116 Event code definitions application notes

3549 88030ddd 6 d dd Storage Cell: %1 Event ID: %2 Description: A drive enclosure I/O module error has occurred. The handle field contains the WWN of the shelf containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the rack_num field will not be valid until a future release. The location of the I/O module (A (01) and B (02)) is identified in the alarm_error_code.field.en field. The cause of the improper operation is described by the content of the alarm_error_code.field.ec field as follows: 1 = The I/O module’s Fibre Channel link speed is not supported by the backplane. This error prevents the controller from establishing a link with enclosure drives and eliminates the enclosure dual-loop capability. 11 = Unable to write data to the I/O module NVRAM. 12 = Unable to read data from the I/O module NVRAM. 13 = The I/O module that was in this location has been removed. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 117: c00287657

Command View EVA event codes

117Event code definitions application notes

3550 88030dde 3 d de Storage Cell: %1 Event ID: %2 Description: A drive enclosure I/O module is unable to communicate with the Drive Enclosure Environmental Monitoring Unit. The handle field contains the WWN of the shelf containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the rack_num field will not be valid until a future release. The location of the I/O module (A (01) and B (02)) is identified in the alarm_error_code.field.en field. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 118: c00287657

Command View EVA event codes

118 Event code definitions application notes

3564 88030dec 3 d ec Storage Cell: %1 Event ID: %2 Description: A drive enclosure I/O module invalid NVRAM read error has occurred. The handle field contains the WWN of the shelf containing the Drive Enclosure Environmental Monitoring Unit.This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. If dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the rack_num field will not be valid until a future release. The location of the I/O module (A (01) or B (02)) is identified in the alarm_error_code.field.en field. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

3568 88030df0 2 d f0 Storage Cell: %1 Event ID: %2 Description: The status has changed on one or more of the drive enclosures. This is an informational event triggered by the occurrence of a change in the status of a drive enclosure. This event is generated for the HSV element manager GUI and contains no user information. The content of the handle, alarm_error_code field, dencl_num, and rack_num fields have no meaning for this event. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. If enclosures.dencl_num is greater than 99, the HSV controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. Note that the content of the enclosures.rack_num field will not be valid until a future release.

16896 88034200 2 42 0 Storage Cell: %1 Event ID: %2 Description: Indicated Host Fibre Channel port transitioned to link down.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 119: c00287657

Command View EVA event codes

119Event code definitions application notes

16897 88034201 2 42 1 Storage Cell: %1 Event ID: %2 Description: Indicated Host Fibre Channel port transitioned to link failed.

16899 88034203 2 42 3 Storage Cell: %1 Event ID: %2 Description: An excessive number of link errors were detected on a HSV controller’s Fibre Channel port. The identity of the affected Fibre Channel port is contained in the cerp_id field. The HSV controller internal Fibre Channel port number of the affected Fibre Channel port is contained in the port field. This is an informational event triggered by the occurrence of an excessive number of Tachyon chip link status errors detected within a particular link status error type. The number of occurrences of each link status error type is contained in a separate type-specific field (e.g., loss_of_signal, bad_rx_char, etc.). The HSV controller checks each of its Fibre Channel port’s for excessive link status errors periodically.

16900 88034204 3 42 4 Storage Cell: %1 Event ID: %2 Description: A Fibre Channel port on the HSV controller has failed to respond. The identity of the affected Fibre Channel port is contained in the cerp_id field. The HSV controller internal Fibre Channel port number of the affected Fibre Channel port is contained in the port field. The peb array contains the port event block information. The peq_frz_prod_index field contains the index to the port event block in use when the Tachyon chip entered the frozen state. The peq_prod_index field contains the index to the next port event block. The peq_cons_index field contains the index to the next port event block to be acted upon.

33536 88038300 6 83 0 Storage Cell: %1 Event ID: %2 Description: A failure was detected during the execution of this HSV controller’s on board diagnostics.

Table 9: Command View EVA Event Codes: Controller Events (Continued)

Event ID

Event Code

Sev- erity

SWCID

Evt. No. Description

Page 120: c00287657

Command View EVA event codes

120 Event code definitions application notes

Management Agent eventsTable 10 describes the events generated by the Command View EVA Agent. These events are logged in the Storage Management Appliance Event Log. You can use the Event Number (Evt. No.) codes to correlate events recorded in the Management Agent Event Log of Command View EVA with the events recorded in the Storage Management Appliance Event Log.

Table 10: Command View EVA Event Codes: Management Agent Events

Event ID Event CodeSev-erity

Evt. No. Description

20000 88034e20 3 0 Storage Cell: %1 Unrecognized Management event generated. Event ID: %2 Description: %3

20001 88034e21 2 1 Storage Cell: %1 Object Already Exists Event ID: %2 Description: %3

20002 88034e22 2 2 Storage Cell: %1 Supplied Buffer Too Small Event ID: %2 Description: %3

20003 88034e23 2 3 Storage Cell: %1 Object Already Assigned Event ID: %2 Description: %3

20004 88034e24 6 4 Storage Cell: %1 Insufficient Available Data Storage Event ID: %2 Description: %3

20005 88034e25 3 5 Storage Cell: %1 Internal Error Event ID: %2 Description: %3

20006 88034e26 2 6 Storage Cell: %1 Invalid status for logical disk Event ID: %2 Description: %3

20007 88034e27 2 7 Storage Cell: %1 Invalid Class Event ID: %2 Description: %3

20008 88034e28 2 8 Storage Cell: %1 Invalid Function Event ID: %2 Description: %3

20009 88034e29 2 9 Storage Cell: %1 Invalid Logical Disk Block State Event ID: %2 Description: %3

20010 88034e2a 2 10 Storage Cell: %1 Invalid Loop Configuration Event ID: %2 Description: %3

20011 88034e2b 2 11 Storage Cell: %1 Invalid Parameter Event ID: %2 Description: %3

20012 88034e2c 2 12 Storage Cell: %1 Invalid Parameter handle Event ID: %2 Description: %3

20013 88034e2d 2 13 Storage Cell: %1 Invalid Parameter Id Event ID: %2 Description: %3

20014 88034e2e 2 14 Storage Cell: %1 Invalid Quorum Configuration Event ID: %2 Description: %3

20015 88034e2f 2 15 Storage Cell: %1 Invalid Target Handle Event ID: %2 Description: %3

20016 88034e30 2 16 Storage Cell: %1 Invalid Target Id Event ID: %2 Description: %3

20017 88034e31 2 17 Storage Cell: %1 Invalid Time Event ID: %2 Description: %3

20018 88034e32 3 18 Storage Cell: %1 Media is Inaccessible Event ID: %2 Description: %3

20019 88034e33 3 19 Storage Cell: %1 No Fibre Channel Port Event ID: %2 Description: %3

20020 88034e34 2 20 Storage Cell: %1 No Image Event ID: %2 Description: %3

20021 88034e35 2 21 Storage Cell: %1 No Permission Event ID: %2 Description: %3

20022 88034e36 2 22 Storage Cell: %1 Storage system not initialized Event ID: %2 Description: %3

20023 88034e37 2 23 Storage Cell: %1 Not a Loop Port Event ID: %2 Description: %3

20024 88034e38 2 24 Storage Cell: %1 Not a Participating Controller Event ID: %2 Description: %3

20025 88034e39 2 25 Storage Cell: %1 Objects in your system are in use, and their state prevents the operation you wish to perform. Event ID: %2 Description: %3

20026 88034e3a 2 26 Storage Cell: %1 Parameter Object Does Not Exist Event ID: %2 Description: %3

20027 88034e3b 2 27 Storage Cell: %1 Target Object Does Not Exist Event ID: %2 Description: %3

20028 88034e3c 2 28 Storage Cell: %1 Timeout Event ID: %2 Description: %3

20029 88034e3d 2 29 Storage Cell: %1 Unknown Id Event ID: %2 Description: %3

20030 88034e3e 2 30 Storage Cell: %1 Unknown Parameter Handle Event ID: %2 Description: %3

20031 88034e3f 2 31 Storage Cell: %1 Unrecoverable Media Error Event ID: %2 Description: %3

Page 121: c00287657

Command View EVA event codes

121Event code definitions application notes

20032 88034e40 2 32 Storage Cell: %1 Invalid State Event ID: %2 Description: %3

20033 88034e41 3 33 Storage Cell: %1 Transport Error Event ID: %2 Description: %3

20034 88034e42 3 34 Storage Cell: %1 Volume is Missing Event ID: %2 Description: %3

20035 88034e43 2 35 Storage Cell: %1 Invalid Cursor Event ID: %2 Description: %3

20036 88034e44 2 36 Storage Cell: %1 Invalid Target for the Operation Event ID: %2 Description: %3

20037 88034e45 2 37 Storage Cell: %1 No More Events Event ID: %2 Description: %3

20038 88034e46 2 38 Storage Cell: %1 Lock Busy Event ID: %2 Description: %3

20039 88034e47 2 39 Storage Cell: %1 Time Not Set Event ID: %2 Description: %3

20040 88034e48 2 40 Storage Cell: %1 Not a Supported Version Event ID: %2 Description: %3

20041 88034e49 2 41 Storage Cell: %1 No Logical Disk for Vdisk Event ID: %2 Description: %3

20042 88034e4a 2 42 Storage Cell: %1 Logical disk Presented Event ID: %2 Description: %3

20043 88034e4b 3 43 Storage Cell: %1 Operation Denied On Slave Event ID: %2 Description: %3

20044 88034e4c 2 44 Storage Cell: %1 Not licensed for data replication Event ID: %2 Description: %3

20045 88034e4d 2 45 Storage Cell: %1 Not DR group member Event ID: %2 Description: %3

20046 88034e4e 2 46 Storage Cell: %1 Invalid DR mode Event ID: %2 Description: %3

20047 88034e4f 2 47 Storage Cell: %1 Invalid DR State Event ID: %2 Description: %3

20048 88034e50 2 48 Storage Cell: %1 Security credentials needed. Please update your system’s ID and password in the Storage System Access menu. Event ID: %2 Description: %3

20049 88034e51 2 49 Storage Cell: %1 Security credentials supplied were invalid. Please update your system’s ID and password in the Storage System Access menu. Event ID: %2 Description: %3

20050 88034e52 2 50 Storage Cell: %1 Security credentials supplied were invalid. Please update your system’s ID and password in the Storage System Access menu. Event ID: %2 Description: %3

20051 88034e53 3 51 Storage Cell: %1 Storage system connection down Event ID: %2 Description: %3

20052 88034e54 2 52 Storage Cell: %1 DR group empty Event ID: %2 Description: %3

20053 88034e55 2 53 Storage Cell: %1 Incompatible attribute Event ID: %2 Description: %3

20054 88034e56 2 54 Storage Cell: %1 Vdisk is a DR group member Event ID: %2 Description: %3

20055 88034e57 2 55 Storage Cell: %1 Vdisk is a DR log unit Event ID: %2 Description: %3

20056 88034e58 2 56 Storage Cell: %1 Cache batteries failed or missing. Event ID: %2 Description: %3

20057 88034e59 2 57 Storage Cell: %1 Vdisk is not presented Event ID: %2 Description: %3

20058 88034e5a 3 58 Storage Cell: %1 Other controller failed Event ID: %2 Description: %3

20059 88034e5b 2 59 Storage Cell: %1 Maximum Number of Objects Exceeded. Event ID: %2 Description: %3

20060 88034e5c 2 60 Storage Cell: %1 Max size Event ID: %2 Description: %3

20061 88034e5d 2 61 Storage Cell: %1 Password mismatch. Please update your system’s password in the Storage System Access menu. Continued attempts to access this storage system with an incorrect password will disable management of this storage system. Event ID: %2 Description: %3

Table 10: Command View EVA Event Codes: Management Agent Events (Continued)

Event ID Event CodeSev-erity

Evt. No. Description

Page 122: c00287657

Command View EVA event codes

122 Event code definitions application notes

20062 88034e5e 2 62 Storage Cell: %1 DR group is merging Event ID: %2 Description: %3

20063 88034e5f 2 63 Storage Cell: %1 DR group is logging Event ID: %2 Description: %3

20064 88034e60 2 64 Storage Cell: %1 Connection is suspended Event ID: %2 Description: %3

20065 88034e61 2 65 Storage Cell: %1 Bad image header Event ID: %2 Description: %3

20066 88034e62 2 66 Storage Cell: %1 Bad image Event ID: %2 Description: %3

20067 88034e63 2 67 Storage Cell: %1 Image too large Event ID: %2 Description: %3

20068 88034e64 2 68 Storage Cell: %1 EMU not available Event ID: %2 Description: %3

20069 88034e65 2 69 Storage Cell: %1 EMU indefinite delay Event ID: %2 Description: %3

20070 88034e66 2 70 Storage Cell: %1 Image incompatible with system configuration. Version conflict in upgrade or downgrade not allowed. Event ID: %2 Description: %3

20071 88034e67 2 71 Storage Cell: %1 Bad image segment Event ID: %2 Description: %3

20072 88034e68 2 72 Storage Cell: %1 Image already loaded Event ID: %2 Description: %3

20073 88034e69 2 73 Storage Cell: %1 Image Write Error Event ID: %2 Description: %3

20074 88034e6a 2 74 Storage Cell: %1 Logical Disk Sharing Event ID: %2 Description: %3

20075 88034e6b 2 75 Storage Cell: %1 Bad Image Size Event ID: %2 Description: %3

20076 88034e6c 2 76 Storage Cell: %1 Image Load Busy Event ID: %2 Description: %3

20077 88034e6d 6 77 Storage Cell: %1 Volume Failure Predicted Event ID: %2 Description: %3

20078 88034e6e 2 78 Storage Cell: %1 Background allocation on the destination member is in progress. This action must complete before any others can be initiated . Event ID: %2 Description: %3

20079 88034e6f 2 79 Storage Cell: %1 Invalid Predecessor Vdisk Condition Event ID: %2 Description: %3

20080 88034e70 2 80 Storage Cell: %1 Invalid Volume Usage Event ID: %2 Description: %3

20081 88034e71 2 81 Storage Cell: %1 Minimum Volumes In Disk Group Event ID: %2 Description: %3

20082 88034e72 2 82 Storage Cell: %1 Shutdown In Progress Event ID: %2 Description: %3

20083 88034e73 2 83 Storage Cell: %1 Not Ready Event ID: %2 Description: %3

20084 88034e74 2 84 Storage Cell: %1 Is Snapshot Event ID: %2 Description: %3

20085 88034e75 2 85 Storage Cell: %1 Cannot add or remove DR group member. Mirror cache must be active for this Vdisk. Check controller cache condition. Event ID: %2 Description: %3

20086 88034e76 2 86 Storage Cell: %1 Inoperative Event ID: %2 Description: %3

20087 88034e77 3 87 Storage Cell: %1 Disk group inoperative or less than 8 disks in group Event ID: %2 Description: %3

20088 88034e78 6 88 Storage Cell: %1 Storage system inoperative Event ID: %2 Description: %3

20089 88034e79 2 89 Storage Cell: %1 Failsafe Locked Event ID: %2 Description: %3

20090 88034e7a 3 90 Storage Cell: %1 Data Flush Incomplete Event ID: %2 Description: %3

20091 88034e7b 2 91 Storage Cell: %1 Redundancy Mirrored Inoperative Event ID: %2 Description: %3

20092 88034e7c 2 92 Storage Cell: %1 Duplicate LUN Event ID: %2 Description: %3

20093 88034e7d 3 93 Storage Cell: %1 Other remote controller failed Event ID: %2 Description: %3

Table 10: Command View EVA Event Codes: Management Agent Events (Continued)

Event ID Event CodeSev-erity

Evt. No. Description

Page 123: c00287657

Command View EVA event codes

123Event code definitions application notes

20094 88034e7e 2 94 Storage Cell: %1 Unknown remote Vdisk Event ID: %2 Description: %3

20095 88034e7f 2 95 Storage Cell: %1 Unknown remote DR group Event ID: %2 Description: %3

20096 88034e80 6 96 Storage Cell: %1 PLDMC failed Event ID: %2 Description: %3

20097 88034e81 6 97 Storage Cell: %1 Storage system could not be locked. System busy. Try command again. Event ID: %2 Description: %3

20098 88034e82 2 98 Storage Cell: %1 Error on remote storage system. Event ID: %2 Description: %3

20099 88034e83 2 99 Storage Cell: %1 This operation can only be completed when the source-destination connection is down. Event ID: %2 Description: %3

20100 88034e84 2 100 Storage Cell: %1 Login required - password changed. Event ID: %2 Description: %3

20101 88034e85 2 101 Storage Cell: %1 Numerous login attempts have been detected that uses an incorrect password. Please update your system’s password in the Storage System Access menu. Event ID: %2 Description: %3

20102 88034e86 2 102 Storage Cell: %1 Invalid cookie Event ID: %2 Description: %3

20103 88034e87 2 103 Storage Cell: %1 Login timed out Event ID: %2 Description: %3

20104 88034e88 2 104 Storage Cell: %1 Max snapshot depth reached Event ID: %2 Description: %3

20105 88034e89 2 105 Storage Cell: %1 Attribute mismatch Event ID: %2 Description: %3

20106 88034e8a 2 106 Storage Cell: %1 Password not set Event ID: %2 Description: %3

20107 88034e8b 2 107 Storage Cell: %1 Not host port Event ID: %2 Description: %3

20108 88034e8c 2 108 Storage Cell: %1 Duplicate Lun WWID Event ID: %2 Description: %3

20109 88034e8d 2 109 Storage Cell: %1 System Inoperative Event ID: %2 Description: %3

20110 88034e8e 2 110 Storage Cell: %1 SnapClone Active Event ID: %2 Description: %3

20111 88034e8f 2 111 Storage Cell: %1 Emu Load Busy Event ID: %2 Description: %3

20112 88034e90 2 112 Storage Cell: %1 Duplicate User Name Event ID: %2 Description: %3

20113 88034e91 2 113 Storage Cell: %1 Drive Reserved For Code Load Event ID: %2 Description: %3

20114 88034e92 2 114 Storage Cell: %1 Already Presented Event ID: %2 Description: %3

20115 88034e93 2 115 Storage Cell: %1 Invalid remote storage system Event ID: %2 Description: %3

20116 88034e94 2 116 Storage Cell: %1 No Lock Event ID: %2 Description: %3

20117 88034e95 2 117 Storage Cell: %1 Maximum Number of Members Exceeded Event ID: %2 Description: %3

20118 88034e96 2 118 Storage Cell: %1 Max Destinations Event ID: %2 Description: %3

20119 88034e97 2 119 Storage Cell: %1 Empty User Name Event ID: %2 Description: %3

20120 88034e98 2 120 Storage Cell: %1 Storage system already initialized Event ID: %2 Description: %3

20121 88034e99 2 121 Storage Cell: %1 Already Open Event ID: %2 Description: %3

20122 88034e9a 2 122 Storage Cell: %1 Session Not Open Event ID: %2 Description: %3

20123 88034e9b 2 123 Storage Cell: %1 Not Marked Inoperative Event ID: %2 Description: %3

20124 88034e9c 2 124 Storage Cell: %1 Media Not Available Event ID: %2 Description: %3

20125 88034e9d 2 125 Storage Cell: %1 Battery System Failed Event ID: %2 Description: %3

20126 88034e9e 2 126 Storage Cell: %1 DR Group Member Is Cache Data Lost Event ID: %2 Description: %3

20127 88034e9f 2 127 Storage Cell: %1 Internal Lock Collision Event ID: %2 Description: %3

Table 10: Command View EVA Event Codes: Management Agent Events (Continued)

Event ID Event CodeSev-erity

Evt. No. Description

Page 124: c00287657

Command View EVA event codes

124 Event code definitions application notes

20128 88034ea0 2 128 Storage Cell: %1 OCP Error Event ID: %2 Description: %3

20129 88034ea1 2 129 Storage Cell: %1 Mirror Offline Event ID: %2 Description: %3

20130 88034ea2 2 130 Storage Cell: %1 This operation cannot be completed if failsafe mode is enabled. Event ID: %2 Description: %3

21000 88035208 2 1000 Storage Cell: %1 Logical Disk Condition Change Event ID: %2 Description: %3

21001 88035209 6 1001 Storage Cell: %1 Storage system is FULL **critical** Event ID: %2 Description: %3

21002 8803520a 3 1002 Storage Cell: %1 Storage system is almost FULL. Disk group at or above maximum capacity warning level. Event ID: %2 Description: %3

21003 8803520b 2 1003 Storage Cell: %1 Controller Cache Battery Condition Change Event ID: %2 Description: %3

21004 8803520c 2 1004 Storage Cell: %1 Controller Cache Condition Change Event ID: %2 Description: %3

21005 8803520d 2 1005 Storage Cell: %1 Controller Condition Change Event ID: %2 Description: %3

21006 8803520e 2 1006 Storage Cell: %1 Controller FC Port Condition Change Event ID: %2 Description: %3

21007 8803520f 2 1007 Storage Cell: %1 Physical Device Condition Change Event ID: %2 Description: %3

21008 88035210 2 1008 Storage Cell: %1 Physical Store Condition Change Event ID: %2 Description: %3

21009 88035211 2 1009 Storage Cell: %1 Host condition change Event ID: %2 Description: %3

21010 88035212 2 1010 Storage Cell: %1 Storage system time has been set Event ID: %2 Description: %3

21011 88035213 2 1011 Storage Cell: %1 Volume Condition change Event ID: %2 Description: %3

21012 88035214 2 1012 Storage Cell: %1 Volume insufficient_resources condition change Event ID: %2 Description: %3

21013 88035215 2 1013 Storage Cell: %1 Volume Quorum Disk change Event ID: %2 Description: %3

21014 88035216 2 1014 Storage Cell: %1 The state of an object in the system has changed. View adjacent events for more detail. Event ID: %2 Description: %3

22001 880355f1 6 2001 Storage Cell: %1 Startup Failed Event ID: %2 Description: %3

22002 880355f2 2 2002 Storage Cell: %1 Management agent event log cleared successfully Event ID: %2 Description: %3

22003 880355f3 3 2003 Storage Cell: %1 Invalid name specified for storage system Event ID: %2 Description: %3

22004 880355f4 2 2004 Storage Cell: %1 Storage system is not initialized Event ID: %2 Description: %3

22005 880355f5 3 2005 Storage Cell: %1 Duplicate name for virtual disk found Event ID: %2 Description: %3

22006 880355f6 3 2006 Storage Cell: %1 Invalid name specified for Vdisk Event ID: %2 Description: %3

22007 880355f7 3 2007 Storage Cell: %1 Vdisk name exceeds maximum length Event ID: %2 Description: %3

22008 880355f8 3 2008 Storage Cell: %1 Invalid parameter specified for Vdisk Event ID: %2 Description: %3

22009 880355f9 3 2009 Storage Cell: %1 No virtual disk found Event ID: %2 Description: %3

Table 10: Command View EVA Event Codes: Management Agent Events (Continued)

Event ID Event CodeSev-erity

Evt. No. Description

Page 125: c00287657

Command View EVA event codes

125Event code definitions application notes

22010 880355fa 3 2010 Storage Cell: %1 Specified Vdisk size exceeds available size Event ID: %2 Description: %3

22011 880355fb 2 2011 Storage Cell: %1 There are not enough disk drives to create a disk group Event ID: %2 Description: %3

22012 880355fc 3 2012 Storage Cell: %1 Number of devices exceeds the available number of disks Event ID: %2 Description: %3

22013 880355fd 3 2013 Storage Cell: %1 Number of devices is less than the minimum number required to create a disk group Event ID: %2 Description: %3

22014 880355fe 3 2014 Storage Cell: %1 No available volumes to complete the request Event ID: %2 Description: %3

22015 880355ff 3 2015 Storage Cell: %1 Specified spare count exceeds maximum count Event ID: %2 Description: %3

22016 88035600 3 2016 Storage Cell: %1 Completed unpresenting virutal disk to host Event ID: %2 Description: %3

22017 88035601 3 2017 Storage Cell: %1 Negative value for device count is invalid Event ID: %2 Description: %3

22018 88035602 3 2018 Storage Cell: %1 Specified spare count is below minimum count Event ID: %2 Description: %3

22019 88035603 3 2019 Storage Cell: %1 Specified device count is below minimum count Event ID: %2 Description: %3

22020 88035604 3 2020 Storage Cell: %1 Requested device count exceeds available physical store Event ID: %2 Description: %3

22021 88035605 3 2021 Storage Cell: %1 Invalid refresh interval value. Should be numeric and non-negative. Event ID: %2 Description: %3

22022 88035606 3 2022 Storage Cell: %1 Invalid security message. Should not be blank. Event ID: %2 Description: %3

22023 88035607 2 2023 Storage Cell: %1 Vdisk Create Complete Event ID: %2 Description: %3

22024 88035608 2 2024 Storage Cell: %1 Storage system uninitialized Event ID: %2 Description: %3

22025 88035609 2 2025 Storage Cell: %1 Storage system successfully initialized Event ID: %2 Description: %3

22026 8803560a 2 2026 Storage Cell: %1 Device Added Successfully Event ID: %2 Description: %3

22027 8803560b 2 2027 Storage Cell: %1 Storage system successfully renamed Event ID: %2 Description: %3

22028 8803560c 2 2028 Storage Cell: %1 Virtual Disk Delete Complete Event ID: %2 Description: %3

22029 8803560d 2 2029 Storage Cell: %1 Virtual Disk Renamed - Complete Event ID: %2 Description: %3

22030 8803560e 2 2030 Storage Cell: %1 Refresh Interval Changed Event ID: %2 Description: %3

22031 8803560f 2 2031 Storage Cell: %1 Security Message Changed Event ID: %2 Description: %3

22032 88035610 2 2032 Storage Cell: %1 Present Vdisk to a Host - Complete Event ID: %2 Description: %3

22033 88035611 2 2033 Storage Cell: %1 Control Startup Complete Event ID: %2 Description: %3

22034 88035612 2 2034 Storage Cell: %1 Change Device Usage Complete Event ID: %2 Description: %3

22035 88035613 2 2035 Storage Cell: %1 Control Shutdown - Complete Event ID: %2 Description: %3

Table 10: Command View EVA Event Codes: Management Agent Events (Continued)

Event ID Event CodeSev-erity

Evt. No. Description

Page 126: c00287657

Command View EVA event codes

126 Event code definitions application notes

22036 88035614 2 2036 Storage Cell: %1 Controller Shutdown - Complete Event ID: %2 Description: %3

22037 88035615 2 2037 Storage Cell: %1 Nsc Crash - Complete Event ID: %2 Description: %3

22038 88035616 6 2038 Storage Cell: %1 Control Memory Allocation Failure Event ID: %2 Description: %3

22039 88035617 2 2039 Storage Cell: %1 There must be at least 5 member devices to create Raid 5 VD Event ID: %2 Description: %3

22040 88035618 2 2040 Storage Cell: %1 Access level denied or session activity timeout. Please log in again. Event ID: %2 Description: %3

22041 88035619 2 2041 Storage Cell: %1 Vdisk Snapshot - Completed Event ID: %2 Description: %3

22042 8803561a 2 2042 Storage Cell: %1 Vdisk Snapclone - Completed Event ID: %2 Description: %3

22043 8803561b 2 2043 Storage Cell: %1 Virtual Disk Snapshot - Failed Event ID: %2 Description: %3

22044 8803561c 2 2044 Storage Cell: %1 Virtual Disk Snapclone - Failed Event ID: %2 Description: %3

22045 8803561d 2 2045 Storage Cell: %1 Restore Device - Completed Event ID: %2 Description: %3

22046 8803561e 6 2046 Storage Cell: %1 Device Failed Event ID: %2 Description: %3

22047 8803561f 2 2047 Storage Cell: %1 Host record added successfully Event ID: %2 Description: %3

22048 88035620 2 2048 Storage Cell: %1 Logical component deleted successfully Event ID: %2 Description: %3

22049 88035621 2 2049 Storage Cell: %1 Invalid host adapter ID Event ID: %2 Description: %3

22050 88035622 2 2050 Storage Cell: %1 Specified device is already a member of the system Event ID: %2 Description: %3

22051 88035623 2 2051 Storage Cell: %1 Create Folder - Completed Event ID: %2 Description: %3

22052 88035624 2 2052 Storage Cell: %1 Change Object Properties - Completed Event ID: %2 Description: %3

22053 88035625 2 2053 Storage Cell: %1 Comments exceed maximum size Event ID: %2 Description: %3

22057 88035629 2 2057 Storage Cell: %1 Completed disk group creation Event ID: %2 Description: %3

22058 8803562a 2 2058 Storage Cell: %1 Added host port Event ID: %2 Description: %3

22059 8803562b 2 2059 Storage Cell: %1 Discarded host port Event ID: %2 Description: %3

22060 8803562c 2 2060 Storage Cell: %1 EMU/Shelf code load complete Event ID: %2 Description: %3

22061 8803562d 2 2061 Storage Cell: %1 Operation will exceed the available capacity of the disk group Event ID: %2 Description: %3

22062 8803562e 2 2062 Storage Cell: %1 Controller(s) code load complete Event ID: %2 Description: %3

22063 8803562f 2 2063 Storage Cell: %1 The target device is not in the right condition to perform the operation Event ID: %2 Description: %3

22064 88035630 2 2064 Storage Cell: %1 Storage system Device Addition Policy changed successfully Event ID: %2 Description: %3

22065 88035631 2 2065 Storage Cell: %1 Maximum number of disk groups exceeded Event ID: %2 Description: %3

22066 88035632 3 2066 Storage Cell: %1 Nsa object discard failed. Event ID: %2 Description: %3

22067 88035633 3 2067 Storage Cell: %1 There are not enough disks to meet the minimum number requirement Event ID: %2 Description: %3

Table 10: Command View EVA Event Codes: Management Agent Events (Continued)

Event ID Event CodeSev-erity

Evt. No. Description

Page 127: c00287657

Command View EVA event codes

127Event code definitions application notes

22068 88035634 2 2068 Storage Cell: %1 Entry added successfully in the password file Event ID: %2 Description: %3

22069 88035635 2 2069 Storage Cell: %1 Entry updated successfully in the password file Event ID: %2 Description: %3

22070 88035636 2 2070 Storage Cell: %1 Entry discarded successfully in the password file Event ID: %2 Description: %3

22071 88035637 2 2071 Storage Cell: %1 Storage system is not responding in a timely manner and has been placed into an unknown state. This may be due to a prior command with an excessively long execution time, high I/O load, or a network communications error. Recovery will automatically occur when the storage system is able to respond. Event ID: %2 Description: %3

22072 88035638 2 2072 Storage Cell: %1 Object not found. Operation on this object is completed Event ID: %2 Description: %3

22073 88035639 2 2073 Storage Cell: %1 There is no more available space to create a Vdisk Event ID: %2 Description: %3

22074 8803563a 2 2074 Storage Cell: %1 Name or comments contains invalid character(s) Event ID: %2 Description: %3

22075 8803563b 2 2075 Storage Cell: %1 Duplicate - Another object with the same name is found Event ID: %2 Description: %3

22076 8803563c 2 2076 Storage Cell: %1 No healthy disk group(s) to create a Vdisk. Resolve any abnormal conditions in the disk group first. Event ID: %2 Description: %3

22077 8803563d 2 2077 Storage Cell: %1 Operating System ID must be a valid number. Event ID: %2 Description: %3

22078 8803563e 2 2078 Storage Cell: %1 Watchdog successfully started Event ID: %2 Description: %3

22079 8803563f 2 2079 Storage Cell: %1 Watchdog successfully stopped Event ID: %2 Description: %3

22080 88035640 3 2080 Storage Cell: %1 Delete Event Config List failed Event ID: %2 Description: %3

22081 88035641 2 2081 Storage Cell: %1 Disk group meltdown repaired successfully. Event ID: %2 Description: %3

22082 88035642 2 2082 Storage Cell: %1 There are no available LUNs to present this Vdisk. Event ID: %2 Description: %3

22083 88035643 2 2083 Storage Cell: %1 Controller time synchronization turned on. Event ID: %2 Description: %3

22084 88035644 2 2084 Storage Cell: %1 Controller time synchronization turned off. Event ID: %2 Description: %3

22085 88035645 2 2085 Storage Cell: %1 System login failed. Invalid password. Event ID: %2 Description: %3

22086 88035646 2 2086 Storage Cell: %1 System is not set for password validation. Event ID: %2 Description: %3

22087 88035647 2 2087 Storage Cell: %1 Agent is already logged in to this system. Event ID: %2 Description: %3

22088 88035648 2 2088 Storage Cell: %1 Storage system time set to custom time. Controller time syncronization automatically turned off. Event ID: %2 Description: %3

22089 88035649 2 2089 Storage Cell: %1 Storage system time set to SAN appliance time. Event ID: %2 Description: %3

22090 8803564a 2 2090 Storage Cell: %1 Storage system time set to browser time. Controller time syncronization automatically turned off. Event ID: %2 Description: %3

Table 10: Command View EVA Event Codes: Management Agent Events (Continued)

Event ID Event CodeSev-erity

Evt. No. Description

Page 128: c00287657

Command View EVA event codes

128 Event code definitions application notes

22091 8803564b 2 2091 Storage Cell: %1 Storage system time set to controller time. Controller time syncronization automatically turned off. Event ID: %2 Description: %3

22092 8803564c 2 2092 Storage Cell: %1 DR group not found. Event ID: %2 Description: %3

22093 8803564d 2 2093 Storage Cell: %1 A host must have at least one port. Cannot delete the only host port available. Event ID: %2 Description: %3

22095 8803564f 2 2095 Storage Cell: %1 Host creation failed. Maximum number of hosts reached. Event ID: %2 Description: %3

22096 88035650 2 2096 Storage Cell: %1 Port already exists for this host. Event ID: %2 Description: %3

23001 880359d9 2 3001 Storage Cell: %1 Event Manager Offline Event ID: %2 Description: %3

23002 880359da 2 3002 Storage Cell: %1 Event Manager Online Event ID: %2 Description: %3

23003 880359db 6 3003 Storage Cell: %1 Event Manager - Startup Failed Event ID: %2 Description: %3

23004 880359dc 2 3004 Storage Cell: %1 Event Manager - Startup Complete Event ID: %2 Description: %3

23005 880359dd 3 3005 Storage Cell: %1 Event Manager - Abnormal Startup Event ID: %2 Description: %3

23006 880359de 3 3006 Storage Cell: %1 Event Manager - Shutdown Failed Event ID: %2 Description: %3

23007 880359df 2 3007 Storage Cell: %1 Event Manager - Shutdown Complete Event ID: %2 Description: %3

23008 880359e0 3 3008 Storage Cell: %1 Event Manager - Abnormal Shutdown Event ID: %2 Description: %3

23009 880359e1 3 3009 Storage Cell: %1 Unable to open NSA Local Event Log File Event ID: %2 Description: %3

23010 880359e2 3 3010 Storage Cell: %1 Unable to open NSA Debug File Event ID: %2 Description: %3

23011 880359e3 3 3011 Storage Cell: %1 EM: Agent event file on SC MLD unavailable - trying local event file. Event ID: %2 Description: %3

23012 880359e4 3 3012 Storage Cell: %1 Unable to open Local Temp Event File - possibly no initialized SC Event ID: %2 Description: %3

23013 880359e5 3 3013 Storage Cell: %1 Unable to clear NSA Local Event Log File Event ID: %2 Description: %3

23014 880359e6 3 3014 Storage Cell: %1 Unable to clear NSA Debug File Event ID: %2 Description: %3

23015 880359e7 3 3015 Storage Cell: %1 Unable to clear NSA Event Log File Event ID: %2 Description: %3

23016 880359e8 3 3016 Storage Cell: %1 Local log file found on startup Event ID: %2 Description: %3

23017 880359e9 3 3017 Storage Cell: %1 Event Queue Flush Error Event ID: %2 Description: %3

23018 880359ea 6 3018 Storage Cell: %1 Log Event Action Failed Event ID: %2 Description: %3

23019 880359eb 2 3019 Storage Cell: %1 EM File Manager Online Event ID: %2 Description: %3

23020 880359ec 2 3020 Storage Cell: %1 EM File Manager Offline Event ID: %2 Description: %3

23021 880359ed 2 3021 Storage Cell: %1 EM Log Manager Online Event ID: %2 Description: %3

23022 880359ee 2 3022 Storage Cell: %1 EM Log Manager Offline Event ID: %2 Description: %3

23023 880359ef 2 3023 Storage Cell: %1 Startup Complete Event ID: %2 Description: %3

23024 880359f0 2 3024 Storage Cell: %1 Local NSA logfile is empty Event ID: %2 Description: %3

Table 10: Command View EVA Event Codes: Management Agent Events (Continued)

Event ID Event CodeSev-erity

Evt. No. Description

Page 129: c00287657

Command View EVA event codes

129Event code definitions application notes

23025 880359f1 2 3025 Storage Cell: %1 Event Queue Online Event ID: %2 Description: %3

23026 880359f2 2 3026 Storage Cell: %1 Event Queue Offline Event ID: %2 Description: %3

23027 880359f3 2 3027 Storage Cell: %1 Event Queue is full Event ID: %2 Description: %3

23028 880359f4 3 3028 Storage Cell: %1 Status Descriptions Unavailable Event ID: %2 Description: %3

23029 880359f5 2 3029 Storage Cell: %1 EM Description Mngr Online Event ID: %2 Description: %3

23030 880359f6 2 3030 Storage Cell: %1 EM: User Defined Status Description File Initialized Event ID: %2 Description: %3

23031 880359f7 3 3031 Storage Cell: %1 EM Description Mngr Start Failed Event ID: %2 Description: %3

23032 880359f8 3 3032 Storage Cell: %1 EM Log Mngr Start Failed Event ID: %2 Description: %3

23033 880359f9 3 3033 Storage Cell: %1 EM File Mngr Start Failed Event ID: %2 Description: %3

23034 880359fa 3 3034 Storage Cell: %1 EM Event Queue Start Failed Event ID: %2 Description: %3

23035 880359fb 3 3035 Storage Cell: %1 EM: NSA log file unavailable Event ID: %2 Description: %3

23036 880359fc 6 3036 Storage Cell: %1 EM Memory Allocation Error Event ID: %2 Description: %3

23037 880359fd 3 3037 Storage Cell: %1 EM: Local Event Configuration File Unavailable Event ID: %2 Description: %3

23038 880359fe 3 3038 Storage Cell: %1 EM: MLD Notification File Unavailable - retrieving local backup copy Event ID: %2 Description: %3

23039 880359ff 3 3039 Storage Cell: %1 EM: Local Notification Host List File Unavailable Event ID: %2 Description: %3

23040 88035a00 2 3040 Storage Cell: %1 EM: SCMI returns zero SC Events but reports additional events Event ID: %2 Description: %3

23041 88035a01 2 3041 Storage Cell: %1 Undefined Status Code Event ID: %2 Description: %3

23042 88035a02 2 3042 Storage Cell: %1 Status Code Not Found Event ID: %2 Description: %3

23043 88035a03 2 3043 Storage Cell: %1 EM Failed SC Init - couldn’t retrieve SC Event Event ID: %2 Description: %3

23044 88035a04 2 3044 Storage Cell: %1 Override this description with missing filename Event ID: %2 Description: %3

23045 88035a05 2 3045 Storage Cell: %1 Invalid storage system event sequence number - can’t retrieve event Event ID: %2 Description: %3

23046 88035a06 2 3046 Storage Cell: %1 Invalid SC termination event sequence number - can’t retrieve event Event ID: %2 Description: %3

23047 88035a07 3 3047 Storage Cell: %1 EM: Event config file unavailable from MLD - retrieving local backup copy Event ID: %2 Description: %3

23048 88035a08 2 3048 Storage Cell: %1 EM: Local user defined event state file unavailable Event ID: %2 Description: %3

23049 88035a09 2 3049 Storage Cell: %1 EM: EMU event monitoring thread unable to start Event ID: %2 Description: %3

23050 88035a0a 6 3050 Storage Cell: %1 EM: EMU event - this description will be overwritten Event ID: %2 Description: %3

23051 88035a0b 3 3051 Storage Cell: %1 EM: Failed to write Event Config file to MLD Event ID: %2 Description: %3

23052 88035a0c 3 3052 Storage Cell: %1 EM: Failed to write Notification Host List to MLD Event ID: %2 Description: %3

Table 10: Command View EVA Event Codes: Management Agent Events (Continued)

Event ID Event CodeSev-erity

Evt. No. Description

Page 130: c00287657

Command View EVA event codes

130 Event code definitions application notes

23053 88035a0d 2 3053 Storage Cell: %1 EM: Event Configuration Filename Error or File empty Event ID: %2 Description: %3

23054 88035a0e 2 3054 Storage Cell: %1 EM: Notification Hostlist Filename Error or File empty Event ID: %2 Description: %3

23055 88035a0f 3 3055 Storage Cell: %1 EM: Event Config List Object Reference Error Event ID: %2 Description: %3

23056 88035a10 2 3056 Storage Cell: %1 EM: SC Parse File successfully uploaded Event ID: %2 Description: %3

23057 88035a11 2 3057 Storage Cell: %1 EM: SC Parse File upload failed Event ID: %2 Description: %3

23058 88035a12 3 3058 Storage Cell: %1 EM: Contents of the uploaded parse file invalid - unexpected contents Event ID: %2 Description: %3

23059 88035a13 3 3059 Storage Cell: %1 EM: Parse file is empty Event ID: %2 Description: %3

23060 88035a14 6 3060 Storage Cell: %1 Storage system being shutdown due to a command failure. Event ID: %2 Description: %3

23061 88035a15 2 3061 Storage Cell: %1 EM: Could not retrieve a storage system event Event ID: %2 Description: %3

23062 88035a16 2 3062 Storage Cell: %1 EM: Init SC Event config list failed Event ID: %2 Description: %3

23063 88035a17 3 3063 Storage Cell: %1 Could not initialize Comm infrastructure for event logging to system log Event ID: %2 Description: %3

23064 88035a18 6 3064 Storage Cell: %1 EM: Storage system pointer is NULL! Event ID: %2 Description: %3

23065 88035a19 6 3065 Storage Cell: %1 EM: Failed to log event to the Appliance event log: check if log is full Event ID: %2 Description: %3

23066 88035a1a 3 3066 Storage Cell: %1 EM: Description Mngr initialize storage system failed Event ID: %2 Description: %3

23067 88035a1b 3 3067 Storage Cell: %1 EM: Description file too small. File read problem Or Incomplete file. Event ID: %2 Description: %3

23068 88035a1c 6 3068 Storage Cell: %1 EM: Can’t init NT Event object pointer Event ID: %2 Description: %3

23069 88035a1d 6 3069 Storage Cell: %1 EM: Can’t init NT Notification object pointer Event ID: %2 Description: %3

23070 88035a1e 6 3070 Storage Cell: %1 EM: Appliance Event Logging Failure - log may be full Event ID: %2 Description: %3

23071 88035a1f 3 3071 Storage Cell: %1 EM: SCMI returned bad additional events number Event ID: %2 Description: %3

23072 88035a20 3 3072 Storage Cell: %1 EM: SCMI returned zero sized SC Event Event ID: %2 Description: %3

23073 88035a21 6 3073 Storage Cell: %1 EM: Local event file Size exceeds max size - event logging shutdown Event ID: %2 Description: %3

23074 88035a22 3 3074 Storage Cell: %1 EM: Local event file exceeded max size limit - truncating file Event ID: %2 Description: %3

23075 88035a23 2 3075 Storage Cell: %1 EventQueue index passed is out of bounds Event ID: %2 Description: %3

23076 88035a24 3 3076 Storage Cell: %1 EM: An abnormal number of duplicate events logged - dropping duplicates Event ID: %2 Description: %3

Table 10: Command View EVA Event Codes: Management Agent Events (Continued)

Event ID Event CodeSev-erity

Evt. No. Description

Page 131: c00287657

Command View EVA event codes

131Event code definitions application notes

23077 88035a25 2 3077 Storage Cell: %1 EM: Update of the MLD Status Description file failed Event ID: %2 Description: %3

23078 88035a26 2 3078 Storage Cell: %1 EM: NsaStatusDescriptions.txt open file error Event ID: %2 Description: %3

23079 88035a27 2 3079 Storage Cell: %1 EM: NsaStatusDescriptions.txt file error - file size discrepancy from mld list Event ID: %2 Description: %3

23080 88035a28 6 3080 Storage Cell: %1 SC Event Log has been cleared and restarted. Possible RAID1 Meltdown. Event ID: %2 Description: %3

23081 88035a29 2 3081 Storage Cell: %1 Invalid logType parameter Event ID: %2 Description: %3

23082 88035a2a 2 3082 Storage Cell: %1 Unsupported version Event ID: %2 Description: %3

23083 88035a2b 2 3083 Storage Cell: %1 Log file is empty Event ID: %2 Description: %3

23084 88035a2c 2 3084 Storage Cell: %1 Storage System with this WWN is not visible to this agent or the WWN is invalid Event ID: %2 Description: %3

23085 88035a2d 6 3085 Storage Cell: %1 Pointer to Event Manager is NULL Event ID: %2 Description: %3

23086 88035a2e 2 3086 Storage Cell: %1 Parsefile for current firmware version not found. Upload correct parse file. Event ID: %2 Description: %3

23090 88035a32 2 3090 Storage Cell: %1 The contents of this file appear to be invalid Event ID: %2 Description: %3

23091 88035a33 2 3091 Storage Cell: %1 The MIB failed to build due to a missing parse file. Event ID: %2 Description: %3

23092 88035a34 2 3092 Storage Cell: %1 MLD description file is older than local file but system is downrev Event ID: %2 Description: %3

23094 88035a36 2 3094 Storage Cell: %1 System is initialized: can’t get activeQ events Event ID: %2 Description: %3

23095 88035a37 2 3095 Storage Cell: %1 Failed to write file - file could not be opened. Event ID: %2 Description: %3

24000 88035dc0 2 4000 Storage Cell: %1 MLD Manager Subsystem Error Event ID: %2 Description: %3

24001 88035dc1 2 4001 Storage Cell: %1 MLD Manager Offline Event ID: %2 Description: %3

24002 88035dc2 2 4002 Storage Cell: %1 MLD Manager Online Event ID: %2 Description: %3

24003 88035dc3 2 4003 Storage Cell: %1 MLD Manager Startup Failed Event ID: %2 Description: %3

24004 88035dc4 2 4004 Storage Cell: %1 MLD Manager Startup Complete Event ID: %2 Description: %3

24005 88035dc5 2 4005 Storage Cell: %1 MLD Manager Abnormal Startup Event ID: %2 Description: %3

24006 88035dc6 2 4006 Storage Cell: %1 MLD Manager Shutdown Failed Event ID: %2 Description: %3

24007 88035dc7 2 4007 Storage Cell: %1 MLD Manager Shutdown Complete Event ID: %2 Description: %3

24008 88035dc8 2 4008 Storage Cell: %1 MLD Manager Abnormal Shutdown Event ID: %2 Description: %3

24009 88035dc9 2 4009 Storage Cell: %1 Unable to startup WSA during MldMgr:init Event ID: %2 Description: %3

24010 88035dca 2 4010 Storage Cell: %1 Unable to get Server Host Name during MldMgr:init Event ID: %2 Description: %3

Table 10: Command View EVA Event Codes: Management Agent Events (Continued)

Event ID Event CodeSev-erity

Evt. No. Description

Page 132: c00287657

Command View EVA event codes

132 Event code definitions application notes

24011 88035dcb 2 4011 Storage Cell: %1 Invalid Host IP Address specified Event ID: %2 Description: %3

24012 88035dcc 2 4012 Storage Cell: %1 Unable to open the NsaMldMgr.dat file for Write Event ID: %2 Description: %3

24013 88035dcd 2 4013 Storage Cell: %1 Unable to open the NsaMldMgr.dat file for Read Event ID: %2 Description: %3

24014 88035dce 2 4014 Storage Cell: %1 Agent Uid does not exist Event ID: %2 Description: %3

24015 88035dcf 2 4015 Storage Cell: %1 Unable to find object Event ID: %2 Description: %3

24016 88035dd0 2 4016 Storage Cell: %1 Unable to store object Event ID: %2 Description: %3

24017 88035dd1 2 4017 Storage Cell: %1 Unable to find storage system object Event ID: %2 Description: %3

24018 88035dd2 2 4018 Storage Cell: %1 Unable to create MLD Event ID: %2 Description: %3

24019 88035dd3 2 4019 Storage Cell: %1 lastSafeChoiceDelay Expired Event ID: %2 Description: %3

24020 88035dd4 2 4020 Storage Cell: %1 lastSafeChoiceDelay Expired Event ID: %2 Description: %3

24021 88035dd5 2 4021 Storage Cell: %1 crashDetectDelay Expired Event ID: %2 Description: %3

24022 88035dd6 2 4022 Storage Cell: %1 retSCCBNum not an SCCB Num Event ID: %2 Description: %3

24023 88035dd7 2 4023 Storage Cell: %1 Unable to read Copy1 of MLD Event ID: %2 Description: %3

24024 88035dd8 2 4024 Storage Cell: %1 Copy 1 of MLD Invalid Event ID: %2 Description: %3

24025 88035dd9 2 4025 Storage Cell: %1 Invalid Copy block of MLD Event ID: %2 Description: %3

24026 88035dda 2 4026 Storage Cell: %1 Copy 2 of MLD Invalid Event ID: %2 Description: %3

24027 88035ddb 2 4027 Storage Cell: %1 MLD database capacity not equal to true MLD capacity Event ID: %2 Description: %3

24028 88035ddc 2 4028 Storage Cell: %1 Backup range out of bounds of copy 1 range Event ID: %2 Description: %3

24029 88035ddd 2 4029 Storage Cell: %1 MLD Manager Lock Crash DetectDelay has expired, just taking lock! Event ID: %2 Description: %3

24030 88035dde 2 4030 Storage Cell: %1 MLD Copy 1 Restored Event ID: %2 Description: %3

24031 88035ddf 2 4031 Storage Cell: %1 MLD Copy 2 Restored Event ID: %2 Description: %3

24032 88035de0 2 4032 Storage Cell: %1 Unable to find UidAssoc Object Event ID: %2 Description: %3

24033 88035de1 2 4033 Storage Cell: %1 Unable to store UID Association Object Event ID: %2 Description: %3

24034 88035de2 2 4034 Storage Cell: %1 Unable to find UidAssoc Object Event ID: %2 Description: %3

24035 88035de3 2 4035 Storage Cell: %1 Unable to read last Fusion event read Event ID: %2 Description: %3

24036 88035de4 2 4036 Storage Cell: %1 MLD Notification Queue Empty Event ID: %2 Description: %3

24037 88035de5 2 4037 Storage Cell: %1 Unable to find Notification Object Event ID: %2 Description: %3

24038 88035de6 2 4038 Storage Cell: %1 Unable to store Notification Object Event ID: %2 Description: %3

24039 88035de7 2 4039 Storage Cell: %1 Unable to find Notification Object Event ID: %2 Description: %3

24040 88035de8 2 4040 Storage Cell: %1 Unable to read Event Log Pointer Event ID: %2 Description: %3

Table 10: Command View EVA Event Codes: Management Agent Events (Continued)

Event ID Event CodeSev-erity

Evt. No. Description

Page 133: c00287657

Command View EVA event codes

133Event code definitions application notes

24041 88035de9 2 4041 Storage Cell: %1 Unable to read Event Log Event ID: %2 Description: %3

24042 88035dea 2 4042 Storage Cell: %1 Unable to store Event Log Event ID: %2 Description: %3

24043 88035deb 2 4043 Storage Cell: %1 Unable to read Event Log Event ID: %2 Description: %3

24044 88035dec 2 4044 Storage Cell: %1 Unable to read Event Log and free Lock Event ID: %2 Description: %3

24045 88035ded 2 4045 Storage Cell: %1 Unable to store Event Log and free Lock Event ID: %2 Description: %3

24046 88035dee 2 4046 Storage Cell: %1 Unable to read Event Log and free Lock Event ID: %2 Description: %3

24047 88035def 2 4047 Storage Cell: %1 Previously Read Object Properties do not Match Event ID: %2 Description: %3

24048 88035df0 2 4048 Storage Cell: %1 Previously Read Object Properties do not Match Event ID: %2 Description: %3

24049 88035df1 2 4049 Storage Cell: %1 Unable to read Notification Host List Event ID: %2 Description: %3

24050 88035df2 2 4050 Storage Cell: %1 Unable to store Notification Host List Event ID: %2 Description: %3

24051 88035df3 2 4051 Storage Cell: %1 Unable to store Notification Host List and free Lock Event ID: %2 Description: %3

24052 88035df4 2 4052 Storage Cell: %1 Unable to read Event Configuration List Event ID: %2 Description: %3

24053 88035df5 2 4053 Storage Cell: %1 Unable to store Event Configuration List Event ID: %2 Description: %3

24054 88035df6 2 4054 Storage Cell: %1 Unable to store Event Configuration List and free Lock Event ID: %2 Description: %3

24055 88035df7 2 4055 Storage Cell: %1 MLD roll up buffer full Event ID: %2 Description: %3

24056 88035df8 2 4056 Storage Cell: %1 MLD roll up list read error Event ID: %2 Description: %3

24057 88035df9 2 4057 Storage Cell: %1 MLD Monitor Lock error Event ID: %2 Description: %3

24058 88035dfa 2 4058 Storage Cell: %1 MLD Manager Mutex Timeout error Event ID: %2 Description: %3

24059 88035dfb 2 4059 Storage Cell: %1 MLD Manager list is empty Event ID: %2 Description: %3

25001 880361a9 2 5001 Storage Cell: %1 Monitor Startup Complete Event ID: %2 Description: %3

25002 880361aa 2 5002 Storage Cell: %1 Monitor Startup Failed Event ID: %2 Description: %3

25003 880361ab 2 5003 Storage Cell: %1 Monitor ShutDown Complete Event ID: %2 Description: %3

25004 880361ac 6 5004 Storage Cell: %1 Monitor Memory Allocation Failure Event ID: %2 Description: %3

25005 880361ad 2 5005 Storage Cell: %1 Monitor Mark Agent as Inactive Event ID: %2 Description: %3

25006 880361ae 2 5006 Storage Cell: %1 Monitor create thread error Event ID: %2 Description: %3

25007 880361af 2 5007 Storage Cell: %1 Monitor create timer error Event ID: %2 Description: %3

25008 880361b0 2 5008 Storage Cell: %1 Monitor agent registration - Complete Event ID: %2 Description: %3

25009 880361b1 2 5009 Storage Cell: %1 Monitor controller rediscovery - Complete Event ID: %2 Description: %3

Table 10: Command View EVA Event Codes: Management Agent Events (Continued)

Event ID Event CodeSev-erity

Evt. No. Description

Page 134: c00287657

Command View EVA event codes

134 Event code definitions application notes

25010 880361b2 3 5010 Storage Cell: %1 Monitor initiated a storage system management shutdown because of controller failures Event ID: %2 Description: %3

25011 880361b3 2 5011 Storage Cell: %1 Unknown storage system rediscovery complete Event ID: %2 Description: %3

25012 880361b4 2 5012 Storage Cell: %1 Start monitoring thread for storage system - Complete Event ID: %2 Description: %3

25013 880361b5 2 5013 Storage Cell: %1 Start monitoring thread for storage system - Fail Event ID: %2 Description: %3

25014 880361b6 2 5014 Storage Cell: %1 Monitoring thread for storage system terminated Event ID: %2 Description: %3

25015 880361b7 2 5015 Storage Cell: %1 Rediscover unknown storage system - Error Event ID: %2 Description: %3

25016 880361b8 2 5016 Storage Cell: %1 Controller time synchronized to appliance time. Event ID: %2 Description: %3

25017 880361b9 2 5017 Storage Cell: %1 Appliance and controller time checked for synchronization. Event ID: %2 Description: %3

25018 880361ba 2 5018 Storage Cell: %1 Controller and appliance time are the same. No need to synchronize. Event ID: %2 Description: %3

25019 880361bb 2 5019 Storage Cell: %1 Exception caught in monitoring process. Event ID: %2 Description: %3

26001 88036591 2 6001 Storage Cell: %1 Ready Event ID: %2 Description: %3

26002 88036592 2 6002 Storage Cell: %1 Index Out of Range Event ID: %2 Description: %3

26003 88036593 6 6003 Storage Cell: %1 Cannot access storage system. Communications error. Event ID: %2 Description: %3

26004 88036594 2 6004 Storage Cell: %1 No controllers found Event ID: %2 Description: %3

26005 88036595 2 6005 Storage Cell: %1 Invalid Index Event ID: %2 Description: %3

26006 88036596 6 6006 Storage Cell: %1 Memory allocation failure Event ID: %2 Description: %3

26007 88036597 2 6007 Storage Cell: %1 No physical stores found Event ID: %2 Description: %3

26008 88036598 2 6008 Storage Cell: %1 No storage system found Event ID: %2 Description: %3

26009 88036599 2 6009 Storage Cell: %1 No disk group found Event ID: %2 Description: %3

26010 8803659a 2 6010 Storage Cell: %1 Too many disk groups Event ID: %2 Description: %3

26011 8803659b 2 6011 Storage Cell: %1 No volumes found Event ID: %2 Description: %3

26012 8803659c 2 6012 Storage Cell: %1 No Logical Disks Found Event ID: %2 Description: %3

26013 8803659d 2 6013 Storage Cell: %1 Context ID changed during operation Event ID: %2 Description: %3

26014 8803659e 2 6014 Storage Cell: %1 No Name Event ID: %2 Description: %3

26015 8803659f 2 6015 Storage Cell: %1 Name Size Exceeded Event ID: %2 Description: %3

26016 880365a0 2 6016 Storage Cell: %1 Shutdown Complete Event ID: %2 Description: %3

26017 880365a1 2 6017 Storage Cell: %1 Mutex Creation Failure Event ID: %2 Description: %3

26018 880365a2 2 6018 Storage Cell: %1 The command has timed out. Storage system is busy processing previous command. Event ID: %2 Description: %3

26019 880365a3 2 6019 Storage Cell: %1 No MLD Handle Set Event ID: %2 Description: %3

26020 880365a4 2 6020 Storage Cell: %1 Failed Transport Layer Communication - No Such Id Event ID: %2 Description: %3

Table 10: Command View EVA Event Codes: Management Agent Events (Continued)

Event ID Event CodeSev-erity

Evt. No. Description

Page 135: c00287657

Command View EVA event codes

135Event code definitions application notes

26021 880365a5 2 6021 Storage Cell: %1 Failed Transport Layer Communication - TimeOut Event ID: %2 Description: %3

26022 880365a6 2 6022 Storage Cell: %1 No initialized storage system objects found Event ID: %2 Description: %3

26023 880365a7 2 6023 Storage Cell: %1 No Attached Port Found Event ID: %2 Description: %3

26024 880365a8 2 6024 Storage Cell: %1 Failed to get SCMI Object Handle Event ID: %2 Description: %3

26025 880365a9 2 6025 Storage Cell: %1 Shutdown Both Restart And Power Off Requested Event ID: %2 Description: %3

26026 880365aa 2 6026 Storage Cell: %1 Shutdown Drive Shelf Power Off But No Enclosure Power Off Requested Event ID: %2 Description: %3

26027 880365ab 2 6027 Storage Cell: %1 Shutdown Disable Battery But No Enclosure Power Off Requested Event ID: %2 Description: %3

26028 880365ac 2 6028 Storage Cell: %1 Shutdown Disable Battery But Shutdown Unconditional Requested Event ID: %2 Description: %3

26029 880365ad 2 6029 Storage Cell: %1 Shutdown Delay Out Of Range Event ID: %2 Description: %3

26030 880365ae 2 6030 Storage Cell: %1 Cache Write Failure Event ID: %2 Description: %3

26031 880365af 2 6031 Storage Cell: %1 Battery Disable Failure Event ID: %2 Description: %3

26032 880365b0 2 6032 Storage Cell: %1 Drive Shelf Disable Failure Event ID: %2 Description: %3

26033 880365b1 2 6033 Storage Cell: %1 Battery Disable Failed on Both Controllers Batteries Event ID: %2 Description: %3

26034 880365b2 2 6034 Storage Cell: %1 Battery Disable Failed on This Controllers Battery Event ID: %2 Description: %3

26035 880365b3 2 6035 Storage Cell: %1 Battery Disable Failed on the Other Controllers Battery Event ID: %2 Description: %3

26036 880365b4 2 6036 Storage Cell: %1 Requested disk failure protection level is set. Actual level will change when sufficient disk space is available. Event ID: %2 Description: %3

26037 880365b5 2 6037 Storage Cell: %1 Physical Store Contains Stale or Foreign Volume Information. Event ID: %2 Description: %3

26038 880365b6 3 6038 Storage Cell: %1 Controller Resynchronization or Reboot Occurred. Context Error Event ID: %2 Description: %3

26039 880365b7 2 6039 Storage Cell: %1 Bad Command Or Response Cookie Event ID: %2 Description: %3

27001 88036979 2 7001 Storage Cell: %1 More than one storage system found Event ID: %2 Description: %3

27002 8803697a 2 7002 Storage Cell: %1 Storage system already exists Event ID: %2 Description: %3

27003 8803697b 2 7003 Storage Cell: %1 Storage System is not initialized Event ID: %2 Description: %3

27004 8803697c 2 7004 Storage Cell: %1 Storage Object Mngr Ready Event ID: %2 Description: %3

27005 8803697d 2 7005 Storage Cell: %1 Storage Object Mngr Shutdown Complete Event ID: %2 Description: %3

27006 8803697e 2 7006 Storage Cell: %1 Storage system name too long Event ID: %2 Description: %3

28001 88036d61 2 8001 Storage Cell: %1 Invalid Operation Event ID: %2 Description: %3

28002 88036d62 2 8002 Storage Cell: %1 Storage system already created Event ID: %2 Description: %3

Table 10: Command View EVA Event Codes: Management Agent Events (Continued)

Event ID Event CodeSev-erity

Evt. No. Description

Page 136: c00287657

Command View EVA event codes

136 Event code definitions application notes

28003 88036d63 2 8003 Storage Cell: %1 Controller already part of storage system configuration Event ID: %2 Description: %3

28004 88036d64 2 8004 Storage Cell: %1 Physical Store Count Below Minimum Event ID: %2 Description: %3

28005 88036d65 2 8005 Storage Cell: %1 Controller not part of storage system configuration Event ID: %2 Description: %3

28006 88036d66 2 8006 Storage Cell: %1 Failed to uninitialize storage system Event ID: %2 Description: %3

28007 88036d67 3 8007 Storage Cell: %1 Storage system File Open Error Event ID: %2 Description: %3

28008 88036d68 3 8008 Storage Cell: %1 Storage system File Write Error Event ID: %2 Description: %3

28009 88036d69 3 8009 Storage Cell: %1 Storage system File Read Error Event ID: %2 Description: %3

28010 88036d6a 2 8010 Storage Cell: %1 Name too long Event ID: %2 Description: %3

28011 88036d6b 2 8011 Storage Cell: %1 No String Error Event ID: %2 Description: %3

28012 88036d6c 2 8012 Storage Cell: %1 No MLD Handle Found Event ID: %2 Description: %3

28013 88036d6d 2 8013 Storage Cell: %1 No Controllers Found Event ID: %2 Description: %3

28014 88036d6e 2 8014 Storage Cell: %1 Controller Not Found On Loop Event ID: %2 Description: %3

28015 88036d6f 2 8015 Storage Cell: %1 No Disk Groups Found Event ID: %2 Description: %3

28016 88036d70 2 8016 Storage Cell: %1 No Volumes Found Event ID: %2 Description: %3

28017 88036d71 2 8017 Storage Cell: %1 No Physical Stores Found Event ID: %2 Description: %3

28018 88036d72 2 8018 Storage Cell: %1 No Vdisks Found Event ID: %2 Description: %3

28019 88036d73 2 8019 Storage Cell: %1 No Hosts Found Event ID: %2 Description: %3

28020 88036d74 2 8020 Storage Cell: %1 Name already exists Event ID: %2 Description: %3

28021 88036d75 2 8021 Storage Cell: %1 Folder is not empty Event ID: %2 Description: %3

28022 88036d76 2 8022 Storage Cell: %1 Spares goal could not be met Event ID: %2 Description: %3

28023 88036d77 2 8023 Storage Cell: %1 Storage system object found Event ID: %2 Description: %3

28024 88036d78 2 8024 Storage Cell: %1 Storage system object not found Event ID: %2 Description: %3

28025 88036d79 2 8025 Storage Cell: %1 New Physical Store Detected But Not Found In Physical Store List Event ID: %2 Description: %3

28026 88036d7a 3 8026 Storage Cell: %1 MldManager Handle is NULL Event ID: %2 Description: %3

28027 88036d7b 3 8027 Storage Cell: %1 NscMngrInterface Handle is NULL Event ID: %2 Description: %3

28028 88036d7c 3 8028 Storage Cell: %1 ScLockMngr Handle is NULL Event ID: %2 Description: %3

28029 88036d7d 6 8029 Storage Cell: %1 Storage system initialization failed Event ID: %2 Description: %3

28030 88036d7e 3 8030 Storage Cell: %1 MldMngr, NscMngrInterfaceMngr, or ScLockMngr Handle is NULL Event ID: %2 Description: %3

28031 88036d7f 6 8031 Storage Cell: %1 Storage system initilization failed Event ID: %2 Description: %3

28032 88036d80 3 8032 Storage Cell: %1 Storage system discovery failed Event ID: %2 Description: %3

28033 88036d81 2 8033 Storage Cell: %1 Storage system already uninitialized or does not exist Event ID: %2 Description: %3

28034 88036d82 3 8034 Storage Cell: %1 Get Total Storage Failed Event ID: %2 Description: %3

28035 88036d83 2 8035 Storage Cell: %1 Storage system is uninitialized Event ID: %2 Description: %3

Table 10: Command View EVA Event Codes: Management Agent Events (Continued)

Event ID Event CodeSev-erity

Evt. No. Description

Page 137: c00287657

Command View EVA event codes

137Event code definitions application notes

28036 88036d84 3 8036 Storage Cell: %1 Get Total Storage Available Failed Event ID: %2 Description: %3

28037 88036d85 3 8037 Storage Cell: %1 Get Total Storage Occupied Failed Event ID: %2 Description: %3

28038 88036d86 3 8038 Storage Cell: %1 Get Total Storage Free Failed Event ID: %2 Description: %3

28039 88036d87 3 8039 Storage Cell: %1 Get Disk Group Failed Event ID: %2 Description: %3

28040 88036d88 3 8040 Storage Cell: %1 Get Disk Group List Failed Event ID: %2 Description: %3

28041 88036d89 3 8041 Storage Cell: %1 Get Disk Group Count Failed Event ID: %2 Description: %3

28042 88036d8a 3 8042 Storage Cell: %1 Create Volume Failed Event ID: %2 Description: %3

28043 88036d8b 3 8043 Storage Cell: %1 Get Volume Failed Event ID: %2 Description: %3

28044 88036d8c 3 8044 Storage Cell: %1 Get Volumes Failed Event ID: %2 Description: %3

28045 88036d8d 3 8045 Storage Cell: %1 Get Volumes Count Failed Event ID: %2 Description: %3

28046 88036d8e 3 8046 Storage Cell: %1 Get Vdisk Failed Event ID: %2 Description: %3

28047 88036d8f 3 8047 Storage Cell: %1 Get Vdisk List Failed Event ID: %2 Description: %3

28048 88036d90 3 8048 Storage Cell: %1 Get Physical Store Failed Event ID: %2 Description: %3

28049 88036d91 3 8049 Storage Cell: %1 Get Physical Stores Failed Event ID: %2 Description: %3

28050 88036d92 3 8050 Storage Cell: %1 Get Physical Stores Count Failed Event ID: %2 Description: %3

28051 88036d93 3 8051 Storage Cell: %1 Create Vdisk Failed Event ID: %2 Description: %3

28052 88036d94 3 8052 Storage Cell: %1 Delete Vdisk Failed Event ID: %2 Description: %3

28053 88036d95 3 8053 Storage Cell: %1 Get Device Addition Policy Failed Event ID: %2 Description: %3

28054 88036d96 3 8054 Storage Cell: %1 Get Spares Current Failed Event ID: %2 Description: %3

28055 88036d97 3 8055 Storage Cell: %1 Get Spares Goal Failed Event ID: %2 Description: %3

28056 88036d98 3 8056 Storage Cell: %1 Get storage system events failed Event ID: %2 Description: %3

28057 88036d99 3 8057 Storage Cell: %1 Get Volume Replacement Delay Failed Event ID: %2 Description: %3

28058 88036d9a 3 8058 Storage Cell: %1 Set Device Addition Policy Failed Event ID: %2 Description: %3

28059 88036d9b 3 8059 Storage Cell: %1 Set Spares Goal Failed Event ID: %2 Description: %3

28060 88036d9c 3 8060 Storage Cell: %1 Set Volume Replacement Delay Failed Event ID: %2 Description: %3

28061 88036d9d 3 8061 Storage Cell: %1 Create controller Failed Event ID: %2 Description: %3

28062 88036d9e 3 8062 Storage Cell: %1 Update controller Failed Event ID: %2 Description: %3

28063 88036d9f 3 8063 Storage Cell: %1 Create Host Failed Event ID: %2 Description: %3

28064 88036da0 3 8064 Storage Cell: %1 Discard Host Failed Event ID: %2 Description: %3

28065 88036da1 3 8065 Storage Cell: %1 Get Host Failed Event ID: %2 Description: %3

28066 88036da2 3 8066 Storage Cell: %1 Get Host List Failed Event ID: %2 Description: %3

28067 88036da3 3 8067 Storage Cell: %1 Get Host Count Failed Event ID: %2 Description: %3

28068 88036da4 3 8068 Storage Cell: %1 Get Presented Unit List Failed Event ID: %2 Description: %3

Table 10: Command View EVA Event Codes: Management Agent Events (Continued)

Event ID Event CodeSev-erity

Evt. No. Description

Page 138: c00287657

Command View EVA event codes

138 Event code definitions application notes

28069 88036da5 3 8069 Storage Cell: %1 Get Presented Unit Count Failed Event ID: %2 Description: %3

28070 88036da6 3 8070 Storage Cell: %1 Free View Failed Event ID: %2 Description: %3

28071 88036da7 3 8071 Storage Cell: %1 Storage system shutdown Failed Event ID: %2 Description: %3

28072 88036da8 3 8072 Storage Cell: %1 StorageCell Virtual Disk Count Does Not Match Logical Disk Count Event ID: %2 Description: %3

28073 88036da9 3 8073 Storage Cell: %1 Get Derived Unit List Failed Event ID: %2 Description: %3

28074 88036daa 3 8074 Storage Cell: %1 Get Derived Unit Count Failed Event ID: %2 Description: %3

28075 88036dab 3 8075 Storage Cell: %1 Get Vdisk list failed Event ID: %2 Description: %3

28076 88036dac 3 8076 Storage Cell: %1 Get Vdisk count failed Event ID: %2 Description: %3

28077 88036dad 3 8077 Storage Cell: %1 Error while building Vdisk root view Event ID: %2 Description: %3

28078 88036dae 3 8078 Storage Cell: %1 Error while building host root view Event ID: %2 Description: %3

28079 88036daf 3 8079 Storage Cell: %1 Error while building disk group root view Event ID: %2 Description: %3

28080 88036db0 3 8080 Storage Cell: %1 Error while building hardware root view Event ID: %2 Description: %3

28081 88036db1 3 8081 Storage Cell: %1 Specified time format is incorrect Event ID: %2 Description: %3

28082 88036db2 3 8082 Storage Cell: %1 Error creating/opening time syncronization file. Event ID: %2 Description: %3

28083 88036db3 3 8083 Storage Cell: %1 NSCList reordered. Event ID: %2 Description: %3

28084 88036db4 3 8084 Storage Cell: %1 NscList mutex Get error Event ID: %2 Description: %3

28085 88036db5 2 8085 Storage Cell: %1 Storage System is managed by another agent Event ID: %2 Description: %3

28086 88036db6 2 8086 Storage Cell: %1 Memory allocation failure Event ID: %2 Description: %3

28087 88036db7 2 8087 Storage Cell: %1 Failed to obtain list of DR Groups Event ID: %2 Description: %3

28088 88036db8 2 8088 Storage Cell: %1 Failed to obtain count of DR Groups Event ID: %2 Description: %3

28089 88036db9 2 8089 Storage Cell: %1 Failed to build DR Group view Event ID: %2 Description: %3

28090 88036dba 3 8090 Storage Cell: %1 No Devices found on Controller Back End Loops Event ID: %2 Description: %3

29001 88037149 3 9001 Storage Cell: %1 Vdisk File Open Error Event ID: %2 Description: %3

29002 8803714a 3 9002 Storage Cell: %1 Vdisk File Write Error Event ID: %2 Description: %3

29003 8803714b 3 9003 Storage Cell: %1 Vdisk File Read Error Event ID: %2 Description: %3

29004 8803714c 2 9004 Storage Cell: %1 Vdisk name too long Event ID: %2 Description: %3

29005 8803714d 2 9005 Storage Cell: %1 Vdisk No String Error Event ID: %2 Description: %3

29006 8803714e 2 9006 Storage Cell: %1 Vdisk No Object Error Event ID: %2 Description: %3

29007 8803714f 2 9007 Storage Cell: %1 Vdisk still exists Event ID: %2 Description: %3

29008 88037150 2 9008 Storage Cell: %1 Vdisk Invalid Value Event ID: %2 Description: %3

Table 10: Command View EVA Event Codes: Management Agent Events (Continued)

Event ID Event CodeSev-erity

Evt. No. Description

Page 139: c00287657

Command View EVA event codes

139Event code definitions application notes

29009 88037151 2 9009 Storage Cell: %1 An outstanding command is still in progress for the Vdisk Event ID: %2 Description: %3

29010 88037152 2 9010 Storage Cell: %1 Requested Vdisk size exceeds the available size Event ID: %2 Description: %3

29011 88037153 2 9011 Storage Cell: %1 Vdisk size may be expanded but not reduced Event ID: %2 Description: %3

29012 88037154 2 9012 Storage Cell: %1 Operation on a fast Vdisk deletion completed Event ID: %2 Description: %3

29013 88037155 2 9013 Storage Cell: %1 Operation on a fast Vdisk creation completed Event ID: %2 Description: %3

29014 88037156 2 9014 Storage Cell: %1 Operation on a fast Vdisk size expansion completed Event ID: %2 Description: %3

29015 88037157 2 9015 Storage Cell: %1 Vdisk cache data lost error Event ID: %2 Description: %3

29016 88037158 2 9016 Storage Cell: %1 Vdisk data lost error resolved Event ID: %2 Description: %3

29017 88037159 2 9017 Storage Cell: %1 Operation rejected - The Vdisk has a sharing relationship with another object Event ID: %2 Description: %3

29018 8803715a 2 9018 Storage Cell: %1 Operation on this Vdisk was rejected due to its degraded condition Event ID: %2 Description: %3

29019 8803715b 2 9019 Storage Cell: %1 Operation on this Vdisk can only be performed if it is presented to a host Event ID: %2 Description: %3

29020 8803715c 2 9020 Storage Cell: %1 Cache policies cannot be modified if Vdisk is presented to a host Event ID: %2 Description: %3

29021 8803715d 2 9021 Storage Cell: %1 Allowed property changes successful. (Cache policy changes not allowed while Vdisk is presented to a host.) Event ID: %2 Description: %3

29022 8803715e 2 9022 Storage Cell: %1 Requested redundancy type cannot be implemented with the current disk group condition. Event ID: %2 Description: %3

29023 8803715f 2 9023 Storage Cell: %1 Your Vdisk was created but cannot be presented at this time. It can be presented when it is fully allocated. Event ID: %2 Description: %3

29024 88037160 2 9024 Storage Cell: %1 Operation would exceed the maximum allowable presented units. Event ID: %2 Description: %3

29025 88037161 2 9025 Storage Cell: %1 Vdisk device data lost error Event ID: %2 Description: %3

29026 88037162 2 9026 Storage Cell: %1 The most significant hex character in a World Wide LUN Name must be a 6. Event ID: %2 Description: %3

29027 88037163 2 9027 Storage Cell: %1 Virtual disk cache and inoperative data lost error Event ID: %2 Description: %3

29028 88037164 2 9028 Storage Cell: %1 Virtual disk inoperative data lost error Event ID: %2 Description: %3

29029 88037165 2 9029 Storage Cell: %1 Virtual disk condition failed because of an inoperative data lost error. Event ID: %2 Description: %3

29030 88037166 2 9030 Storage Cell: %1 Vdisk is a snapshot. The following properties cannot be changed: Preferred Path, Requested Size, Write-Back Cache Policy. Event ID: %2 Description: %3

29031 88037167 2 9031 Storage Cell: %1 The World Wide LUN Name cannot be changed for a presented Vdisk Active member or snapshot. Event ID: %2 Description: %3

29032 88037168 2 9032 Storage Cell: %1 Unknown property, request rejected Event ID: %2 Description: %3

Table 10: Command View EVA Event Codes: Management Agent Events (Continued)

Event ID Event CodeSev-erity

Evt. No. Description

Page 140: c00287657

Command View EVA event codes

140 Event code definitions application notes

29033 88037169 2 9033 Storage Cell: %1 This Vdisk was deleted as the indirect result of another user command. Event ID: %2 Description: %3

29034 8803716a 2 9034 Storage Cell: %1 The requested allocation policy cannot be satisfied. A different allocation policy is already in use by another snapshot in the same family. Event ID: %2 Description: %3

29035 8803716b 2 9035 Storage Cell: %1 The deletion of this Vdisk cannot take place. The original Vdisk that this is being snapcloned from is in a VRaid1 Meltdown state which must first be resolved. Event ID: %2 Description: %3

29036 8803716c 2 9036 Storage Cell: %1 Synchronous creation of virtual disk has been aborted due to an internal error. Switching to asynchronous mode to complete the virtual disk creation. Event ID: %2 Description: %3

30001 88037531 2 10001 Storage Cell: %1 Storage Object Broker Ready Event ID: %2 Description: %3

30002 88037532 3 10002 Storage Cell: %1 Storage Object Startup Failed Event ID: %2 Description: %3

30003 88037533 2 10003 Storage Cell: %1 Invalid storage system name Event ID: %2 Description: %3

30004 88037534 2 10004 Storage Cell: %1 Storage system is not initialized Event ID: %2 Description: %3

30005 88037535 2 10005 Storage Cell: %1 Failed to set storage system name Event ID: %2 Description: %3

30006 88037536 6 10006 Storage Cell: %1 SOB Memory Allocation Failure Event ID: %2 Description: %3

30007 88037537 2 10007 Storage Cell: %1 Failed to find virtual disk from list Event ID: %2 Description: %3

30008 88037538 2 10008 Storage Cell: %1 Failed to find host from list Event ID: %2 Description: %3

30009 88037539 2 10009 Storage Cell: %1 The Lun specified for this Host is already in use Event ID: %2 Description: %3

30010 8803753a 2 10010 Storage Cell: %1 Your initialized system must have at least one disk group Event ID: %2 Description: %3

30011 8803753b 2 10011 Storage Cell: %1 Cannot talk to all available controllers Event ID: %2 Description: %3

30012 8803753c 2 10012 Storage Cell: %1 Command rejected - Folder is not empty Event ID: %2 Description: %3

30013 8803753d 2 10013 Storage Cell: %1 Command rejected - Vdisk(s) or a data replication log are contained in this disk group Event ID: %2 Description: %3

30014 8803753e 2 10014 Storage Cell: %1 Command rejected - Vdisk(s) are presented to this host Event ID: %2 Description: %3

30015 8803753f 2 10015 Storage Cell: %1 Command rejected - This Vdisk has a sharing relationship with another object Event ID: %2 Description: %3

30016 88037540 2 10016 Storage Cell: %1 Target storage system is currently being used by another process Event ID: %2 Description: %3

30017 88037541 2 10017 Storage Cell: %1 Command rejected - Number of disk groups will exceed the maximum allowable number Event ID: %2 Description: %3

30018 88037542 2 10018 Storage Cell: %1 Cannot access the password file Event ID: %2 Description: %3

30019 88037543 2 10019 Storage Cell: %1 Enterprise Login - Complete Event ID: %2 Description: %3

30020 88037544 2 10020 Storage Cell: %1 Command rejected - Number of disks in the group would be below the minimum number required. Event ID: %2 Description: %3

Table 10: Command View EVA Event Codes: Management Agent Events (Continued)

Event ID Event CodeSev-erity

Evt. No. Description

Page 141: c00287657

Command View EVA event codes

141Event code definitions application notes

30021 88037545 2 10021 Storage Cell: %1 Rediscovery of controllers - Complete Event ID: %2 Description: %3

30022 88037546 2 10022 Storage Cell: %1 Unable to establish communication with controller, check all connections. Event ID: %2 Description: %3

30023 88037547 2 10023 Storage Cell: %1 Disk Group Data Lost Error Resolution Sequence 3 - Disk group resolved to normal Event ID: %2 Description: %3

30024 88037548 2 10024 Storage Cell: %1 Disk Group Data Lost Error Resolution Sequence 1 - Failed Vdisks marked for deletion Event ID: %2 Description: %3

30025 88037549 2 10025 Storage Cell: %1 Disk Group Data Lost Error Resolution Sequence 2 - Failed Vdisks deleted Event ID: %2 Description: %3

30026 8803754a 2 10026 Storage Cell: %1 Disk Group Data Lost Error Resolution Sequence 3 - Disk group deleted Event ID: %2 Description: %3

30027 8803754b 2 10027 Storage Cell: %1 Creating the Vdisk would exceed the maximum allowable Vdisk count Event ID: %2 Description: %3

30028 8803754c 2 10028 Storage Cell: %1 Volume insufficient resources Event ID: %2 Description: %3

30029 8803754d 2 10029 Storage Cell: %1 Process mutex is locked Event ID: %2 Description: %3

30030 8803754e 2 10030 Storage Cell: %1 Invalid URL request type Event ID: %2 Description: %3

30031 8803754f 2 10031 Storage Cell: %1 Invalid URL object type Event ID: %2 Description: %3

30034 88037552 2 10034 Storage Cell: %1 The basic license cannot be validated. Either the license key has not been entered, or there is a system communication failure. Event ID: %2 Description: %3

30035 88037553 2 10035 Storage Cell: %1 The snapshot/Snapclone license cannot be validated. Either the license key has not been entered, or there is a system communication failure. Event ID: %2 Description: %3

30036 88037554 2 10036 Storage Cell: %1 A data replication license cannot be validated. Either the license key has not been entered, or there is a system communication failure. Event ID: %2 Description: %3

30037 88037555 2 10037 Storage Cell: %1 Object name should not be empty or exceed its maximum length Event ID: %2 Description: %3

30038 88037556 2 10038 Storage Cell: %1 Object comments exceeds maximum length Event ID: %2 Description: %3

30039 88037557 2 10039 Storage Cell: %1 Vdisk does not meet the requirements to be part of a DR group. Event ID: %2 Description: %3

30040 88037558 2 10040 Storage Cell: %1 The Eva selected as the Destination for the DR group is invalid. Either it has a DR relationship with another EVA or it is not the same EVA that the source EVA presently has a DR relationship with. Event ID: %2 Description: %3

30041 88037559 2 10041 Storage Cell: %1 Cannot group the specified disk device because the disk is already in a disk group. Event ID: %2 Description: %3

30042 8803755a 2 10042 Storage Cell: %1 Cannot ungroup the specified disk device because the disk is not grouped. Event ID: %2 Description: %3

30043 8803755b 2 10043 Storage Cell: %1 Object ID provided, or object type, is invalid for the requested operation. Event ID: %2 Description: %3

31001 88037919 2 11001 Storage Cell: %1 Agent startup complete Event ID: %2 Description: %3

31002 8803791a 2 11002 Storage Cell: %1 Agent shutdown complete Event ID: %2 Description: %3

Table 10: Command View EVA Event Codes: Management Agent Events (Continued)

Event ID Event CodeSev-erity

Evt. No. Description

Page 142: c00287657

Command View EVA event codes

142 Event code definitions application notes

31003 8803791b 6 11003 Storage Cell: %1 Insufficient memory to create a new object, Heap may be full! Event ID: %2 Description: %3

31004 8803791c 6 11004 Storage Cell: %1 Agent Startup Failed Event ID: %2 Description: %3

32000 88037d00 2 12000 Storage Cell: %1 Nsc Manager Interface First Status Event ID: %2 Description: %3

32001 88037d01 2 12001 Storage Cell: %1 Nsc Manager Interface No controllers Found Event ID: %2 Description: %3

32002 88037d02 2 12002 Storage Cell: %1 Nsc Manager Interface Index Out Of Range Event ID: %2 Description: %3

32003 88037d03 2 12003 Storage Cell: %1 Unable to process command at this time. Retry the command or check all connections. Event ID: %2 Description: %3

32004 88037d04 2 12004 Storage Cell: %1 Nsc Manager Interface Initialization Complete Event ID: %2 Description: %3

32005 88037d05 2 12005 Storage Cell: %1 Nsc Manager Interface Initialization Failed Event ID: %2 Description: %3

32007 88037d07 2 12007 Storage Cell: %1 Lock description not null but failed to get context ID Event ID: %2 Description: %3

32008 88037d08 2 12008 Storage Cell: %1 No Disk Groups Available For Access Event ID: %2 Description: %3

33001 880380e9 2 13001 Storage Cell: %1 NM Good Status Event ID: %2 Description: %3

33002 880380ea 2 13002 Storage Cell: %1 Notification Mngr Online Event ID: %2 Description: %3

33003 880380eb 2 13003 Storage Cell: %1 Notification Mngr Offline Event ID: %2 Description: %3

33004 880380ec 2 13004 Storage Cell: %1 NM Startup Complete Event ID: %2 Description: %3

33005 880380ed 6 13005 Storage Cell: %1 NM Startup Failed Event ID: %2 Description: %3

33006 880380ee 2 13006 Storage Cell: %1 Notification Succeeded Event ID: %2 Description: %3

33007 880380ef 6 13007 Storage Cell: %1 Notification Failed Event ID: %2 Description: %3

33008 880380f0 6 13008 Storage Cell: %1 Notification Failed - MLD Error Event ID: %2 Description: %3

33009 880380f1 6 13009 Storage Cell: %1 Notification Failed - Network Error Event ID: %2 Description: %3

33010 880380f2 2 13010 Storage Cell: %1 NM Shutdown Complete Event ID: %2 Description: %3

33011 880380f3 3 13011 Storage Cell: %1 NM Shutdown Failed Event ID: %2 Description: %3

33012 880380f4 2 13012 Storage Cell: %1 NM Prev Failed Notification Successfully Notified Event ID: %2 Description: %3

33013 880380f5 2 13013 Storage Cell: %1 NM SNMP Manager Online Event ID: %2 Description: %3

33014 880380f6 2 13014 Storage Cell: %1 NM SNMP Packet Sent Event ID: %2 Description: %3

33015 880380f7 6 13015 Storage Cell: %1 NM SNMP Packet Failed Event ID: %2 Description: %3

33016 880380f8 2 13016 Storage Cell: %1 NM SNMP Manager Offline Event ID: %2 Description: %3

33017 880380f9 6 13017 Storage Cell: %1 NM Memory Allocation Error Event ID: %2 Description: %3

33018 880380fa 6 13018 Storage Cell: %1 NM StorageCell handle is NULL Event ID: %2 Description: %3

33019 880380fb 2 13019 Storage Cell: %1 NM User defined event state file is empty Event ID: %2 Description: %3

33020 880380fc 3 13020 Storage Cell: %1 NM Notification Failed - Notification Matrix is NULL Event ID: %2 Description: %3

Table 10: Command View EVA Event Codes: Management Agent Events (Continued)

Event ID Event CodeSev-erity

Evt. No. Description

Page 143: c00287657

Command View EVA event codes

143Event code definitions application notes

34001 880384d1 2 14001 Storage Cell: %1 View Already Exists Event ID: %2 Description: %3

34002 880384d2 2 14002 Storage Cell: %1 View Is Not Set Event ID: %2 Description: %3

34003 880384d3 2 14003 Storage Cell: %1 No View Object(s) Found Event ID: %2 Description: %3

34004 880384d4 2 14004 Storage Cell: %1 View Index Is Out Of Range Event ID: %2 Description: %3

34005 880384d5 2 14005 Storage Cell: %1 View Object - Invalid Object Condition Event ID: %2 Description: %3

34006 880384d6 2 14006 Storage Cell: %1 View Object - Invalid Object Type Event ID: %2 Description: %3

34007 880384d7 3 14007 Storage Cell: %1 View List Pointer is NULL Event ID: %2 Description: %3

34008 880384d8 3 14008 Storage Cell: %1 View Object Pointer is NULL Event ID: %2 Description: %3

34009 880384d9 2 14009 Storage Cell: %1 Building View List Object - Complete Event ID: %2 Description: %3

34010 880384da 2 14010 Storage Cell: %1 Building View List Object - Failed Event ID: %2 Description: %3

34011 880384db 2 14011 Storage Cell: %1 View Size is Zero Event ID: %2 Description: %3

34012 880384dc 2 14012 Storage Cell: %1 View Find by UID Failed Event ID: %2 Description: %3

34013 880384dd 2 14013 Storage Cell: %1 View Find by Type Failed Event ID: %2 Description: %3

34014 880384de 2 14014 Storage Cell: %1 View Find by Index Failed Event ID: %2 Description: %3

34015 880384df 2 14015 Storage Cell: %1 View Find by Name Failed Event ID: %2 Description: %3

34016 880384e0 2 14016 Storage Cell: %1 View Find by WWN Failed Event ID: %2 Description: %3

34017 880384e1 2 14017 Storage Cell: %1 View Find by Type by Name Failed Event ID: %2 Description: %3

34018 880384e2 2 14018 Storage Cell: %1 View Find by Name by Type Failed Event ID: %2 Description: %3

35001 880388b9 2 15001 Storage Cell: %1 Tree View Symbol Not Found Event ID: %2 Description: %3

35002 880388ba 2 15002 Storage Cell: %1 Tree View Id Symbol Not Found Event ID: %2 Description: %3

35003 880388bb 2 15003 Storage Cell: %1 Tree Cursor Symbol Not Found Event ID: %2 Description: %3

35004 880388bc 2 15004 Storage Cell: %1 Tree Cursor Id Symbol Not Found Event ID: %2 Description: %3

35005 880388bd 2 15005 Storage Cell: %1 Tree Sibling Symbol Not Found Event ID: %2 Description: %3

35006 880388be 2 15006 Storage Cell: %1 Tree Total Children Symbol Not Found Event ID: %2 Description: %3

35007 880388bf 2 15007 Storage Cell: %1 Tree Expansion Symbol Not Found Event ID: %2 Description: %3

35008 880388c0 2 15008 Storage Cell: %1 Tree Contraction Symbol Not Found Event ID: %2 Description: %3

35009 880388c1 2 15009 Storage Cell: %1 Tree Invalid Descriptor String Event ID: %2 Description: %3

36001 88038ca1 2 16001 Storage Cell: %1 Ema Short Status - Reissue Command Event ID: %2 Description: %3

36002 88038ca2 2 16002 Storage Cell: %1 Ema EMU Could Not Read ALPA Event ID: %2 Description: %3

36003 88038ca3 2 16003 Storage Cell: %1 Ema Invalid Request Event ID: %2 Description: %3

Table 10: Command View EVA Event Codes: Management Agent Events (Continued)

Event ID Event CodeSev-erity

Evt. No. Description

Page 144: c00287657

Command View EVA event codes

144 Event code definitions application notes

36004 88038ca4 2 16004 Storage Cell: %1 Ema Invalid Handle Set In Request Packet Event ID: %2 Description: %3

36005 88038ca5 2 16005 Storage Cell: %1 Ema No Pstore At Referenced Location Event ID: %2 Description: %3

36006 88038ca6 2 16006 Storage Cell: %1 Ema No Primary EMU Selected Event ID: %2 Description: %3

36007 88038ca7 2 16007 Storage Cell: %1 Ema Invalid SubEnclosure ID Specified Event ID: %2 Description: %3

36008 88038ca8 2 16008 Storage Cell: %1 Ema No Device Found Event ID: %2 Description: %3

36009 88038ca9 2 16009 Storage Cell: %1 Ema Request Packet Missing Parameter Event ID: %2 Description: %3

36010 88038caa 2 16010 Storage Cell: %1 Ema Could Not Find SubEnclosure in Configuration List Event ID: %2 Description: %3

36011 88038cab 2 16011 Storage Cell: %1 Ema EMU Alarm Or Status Event Information Event ID: %2 Description: %3

36012 88038cac 2 16012 Storage Cell: %1 Ema Non-specific error occurred Event ID: %2 Description: %3

36013 88038cad 2 16013 Storage Cell: %1 Ema Shelf WWN Could Not Be Accessed Through A Drive Event ID: %2 Description: %3

36014 88038cae 2 16014 Storage Cell: %1 Ema EMU Failed To Enter Primary Mode Event ID: %2 Description: %3

36015 88038caf 2 16015 Storage Cell: %1 Ema EMU Failed To Exit Primary Mode Event ID: %2 Description: %3

36016 88038cb0 2 16016 Storage Cell: %1 Ema Downloaded File Does Not Contain Valid Fibre Channel Loader [status:1] Event ID: %2 Description: %3

36017 88038cb1 2 16017 Storage Cell: %1 Ema Downloaded File Format Is Not Recognized [status:2] Event ID: %2 Description: %3

36018 88038cb2 2 16018 Storage Cell: %1 Ema Incorrect Firmware In Downloaded File [status:3] Event ID: %2 Description: %3

36019 88038cb3 2 16019 Storage Cell: %1 Ema Downloaded Loader is Too Large [status:4] Event ID: %2 Description: %3

36020 88038cb4 2 16020 Storage Cell: %1 Ema Invalid Checksum [status:5] Event ID: %2 Description: %3

36021 88038cb5 2 16021 Storage Cell: %1 Ema Previous Offset Plus Previous Length Not Equal To Current Offset [status:6] Event ID: %2 Description: %3

36022 88038cb6 2 16022 Storage Cell: %1 Ema Downloaded Loader Terminated Incorrectly [status:7] Event ID: %2 Description: %3

36023 88038cb7 2 16023 Storage Cell: %1 Ema EMU Out Of Memory [status:8] Event ID: %2 Description: %3

36024 88038cb8 2 16024 Storage Cell: %1 Ema EMU CDB Timeout -- Download Aborted [status:9] Event ID: %2 Description: %3

36025 88038cb9 2 16025 Storage Cell: %1 Ema EMU Internal State Machine Error [status:10] Event ID: %2 Description: %3

36026 88038cba 2 16026 Storage Cell: %1 Ema EMU Flash Erasure Failure [status:11] Event ID: %2 Description: %3

36027 88038cbb 2 16027 Storage Cell: %1 Ema EMU In Primary Mode - Cannot Download To Primary EMU [status:12] Event ID: %2 Description: %3

Table 10: Command View EVA Event Codes: Management Agent Events (Continued)

Event ID Event CodeSev-erity

Evt. No. Description

Page 145: c00287657

Command View EVA event codes

145Event code definitions application notes

36028 88038cbc 2 16028 Storage Cell: %1 Ema Previous Offset Plus Previous Length Greater Than Total Size [status:13] Event ID: %2 Description: %3

36029 88038cbd 2 16029 Storage Cell: %1 Ema Current Total Size Different From Previous Total Size [status:14] Event ID: %2 Description: %3

36030 88038cbe 2 16030 Storage Cell: %1 Ema Could Not Restore Reporting Group Number. Final Download Record Error Event ID: %2 Description: %3

36031 88038cbf 2 16031 Storage Cell: %1 Ema Could Not Recovery From Invop. Invop Retries Exhausted Event ID: %2 Description: %3

36032 88038cc0 2 16032 Storage Cell: %1 Ema Requested WWN Does Not Match Enclosure WWN Event ID: %2 Description: %3

36033 88038cc1 6 16033 Storage Cell: %1 Ema EMU Enclosure Services Error Occurred. EMU May Be Unavailable or Not Installed Event ID: %2 Description: %3

36034 88038cc2 2 16034 Storage Cell: %1 Ema SCSI Error Occurred While Trying To Communicate With EMU Event ID: %2 Description: %3

36035 88038cc3 2 16035 Storage Cell: %1 Ema Could Not Open EMU Firmware File Event ID: %2 Description: %3

36036 88038cc4 2 16036 Storage Cell: %1 Ema EMU Firmware File Name Is Null Event ID: %2 Description: %3

36037 88038cc5 2 16037 Storage Cell: %1 Ema EMU Firmware Download Retries Exhausted. Manual Download May Be Required Event ID: %2 Description: %3

36038 88038cc6 2 16038 Storage Cell: %1 Ema EMU Current Firmware Version Matches Upgrade Firmware Version. No Upgrade Will Be Performed. Event ID: %2 Description: %3

36039 88038cc7 2 16039 Storage Cell: %1 Ema EMU Firmware Upgrade Success Event ID: %2 Description: %3

36040 88038cc8 2 16040 Storage Cell: %1 Ema EMU In Load State. Do Not Power Off. Reload EMU Firmware Event ID: %2 Description: %3

37001 88039089 2 17001 Storage Cell: %1 Drive Code Load Descriptor File Open Error Event ID: %2 Description: %3

37002 8803908a 2 17002 Storage Cell: %1 Drive Code Load Descriptor File Parsing Error - Invalid Line Event ID: %2 Description: %3

37003 8803908b 2 17003 Storage Cell: %1 Drive Code Load Image File Open Error, Event ID: %2 Description: %3

37004 8803908c 2 17004 Storage Cell: %1 Drive Code Load Image File Error Getting File Size Event ID: %2 Description: %3

37005 8803908d 2 17005 Storage Cell: %1 Drive Code Load Image File Buffer Allocation Error Event ID: %2 Description: %3

37006 8803908e 2 17006 Storage Cell: %1 Drive Code Load Image File Read Error Event ID: %2 Description: %3

37007 8803908f 6 17007 Storage Cell: %1 Drive Code Load Drive Firmware Update Failed Event ID: %2 Description: %3

37008 88039090 3 17008 Storage Cell: %1 Drive Code Load Drive Inquiry Failed Event ID: %2 Description: %3

37009 88039091 3 17009 Storage Cell: %1 Drive Code Load Format Command Failed Event ID: %2 Description: %3

37010 88039092 3 17010 Storage Cell: %1 Drive Code Load Format Failed Event ID: %2 Description: %3

Table 10: Command View EVA Event Codes: Management Agent Events (Continued)

Event ID Event CodeSev-erity

Evt. No. Description

Page 146: c00287657

Command View EVA event codes

146 Event code definitions application notes

37011 88039093 3 17011 Storage Cell: %1 Drive Code Load Restore Volume Failed Event ID: %2 Description: %3

37012 88039094 2 17012 Storage Cell: %1 Drive Code Load Get Physical Store Condition Failed Event ID: %2 Description: %3

37013 88039095 2 17013 Storage Cell: %1 Drive Code Load Get Volume Condition Failed Event ID: %2 Description: %3

37014 88039096 3 17014 Storage Cell: %1 Drive Code Load Drive Spin Up Error Event ID: %2 Description: %3

37015 88039097 2 17015 Storage Cell: %1 Drive Code Load - Complete Event ID: %2 Description: %3

37016 88039098 2 17016 Storage Cell: %1 Drive Code Load Disk Group Migration In Progress Event ID: %2 Description: %3

37017 88039099 2 17017 Storage Cell: %1 Drive Code Load Unable To Code Load Disks Part Of A Group Event ID: %2 Description: %3

38001 88039471 2 18001 Storage Cell: %1 Api Created Element Success Event ID: %2 Description: %3

38002 88039472 2 18002 Storage Cell: %1 Api Created Storage Success Event ID: %2 Description: %3

38003 88039473 2 18003 Storage Cell: %1 Api Created Storage Client Success Event ID: %2 Description: %3

38004 88039474 2 18004 Storage Cell: %1 Api Set Storage Success Event ID: %2 Description: %3

38005 88039475 2 18005 Storage Cell: %1 Api Set Element Success Event ID: %2 Description: %3

38006 88039476 2 18006 Storage Cell: %1 Api Deleted Element Success Event ID: %2 Description: %3

38007 88039477 2 18007 Storage Cell: %1 Api Deleted Storage Success Event ID: %2 Description: %3

38008 88039478 2 18008 Storage Cell: %1 Api Deleted Storage Client Success Event ID: %2 Description: %3

38009 88039479 2 18009 Storage Cell: %1 Api Created Snapshot Success

38010 8803947a 2 18010 Storage Cell: %1 Api Created Clone Success Event ID: %2 Description: %3

38018 88039482 2 18018 Storage Cell: %1 Api Unable To Get The Lock Event ID: %2 Description: %3

38019 88039483 2 18019 Storage Cell: %1 Api Created PresentedUnit Success Event ID: %2 Description: %3

38022 88039486 2 18022 Storage Cell: %1 Api Create DiskGroup Success Event ID: %2 Description: %3

38024 88039488 2 18024 Storage Cell: %1 Api Create Folder Success Event ID: %2 Description: %3

38025 88039489 2 18025 Storage Cell: %1 Api Delete Folder Success Event ID: %2 Description: %3

38028 8803948c 2 18028 Storage Cell: %1 Api Set Folder Success Event ID: %2 Description: %3

38034 88039492 2 18034 Storage Cell: %1 Api Invalid User Name Or Password Error Event ID: %2 Description: %3

38036 88039494 2 18036 Storage Cell: %1 Api Delete Presented Unit Success Event ID: %2 Description: %3

38038 88039496 2 18038 Storage Cell: %1 Api Set Diskgroup Success Event ID: %2 Description: %3

38039 88039497 2 18039 Storage Cell: %1 Api Set Disk Success Event ID: %2 Description: %3

38040 88039498 2 18040 Storage Cell: %1 Api Delete Storage Family Success Event ID: %2 Description: %3

38041 88039499 2 18041 Storage Cell: %1 Api Set Storage Family Success Event ID: %2 Description: %3

38042 8803949a 2 18042 Storage Cell: %1 Api Control Memory Allocation Failure Event ID: %2 Description: %3

Table 10: Command View EVA Event Codes: Management Agent Events (Continued)

Event ID Event CodeSev-erity

Evt. No. Description

Page 147: c00287657

Command View EVA event codes

147Event code definitions application notes

38045 8803949d 2 18045 Storage Cell: %1 Api Element Codeload Success Event ID: %2 Description: %3

38047 8803949f 2 18047 Storage Cell: %1 Api Disk Codeload Success Event ID: %2 Description: %3

38048 880394a0 2 18048 Storage Cell: %1 Api Monitor Codeload Success Event ID: %2 Description: %3

38049 880394a1 2 18049 Storage Cell: %1 Api Added Port WWID Success Event ID: %2 Description: %3

38050 880394a2 2 18050 Storage Cell: %1 Api Set Storage Client Success Event ID: %2 Description: %3

38051 880394a3 2 18051 Storage Cell: %1 Api Invalid Operation Event ID: %2 Description: %3

38052 880394a4 2 18052 Storage Cell: %1 Api Deleted Port WWID Success Event ID: %2 Description: %3

38059 880394ab 2 18059 Storage Cell: %1 Api Set Power Success Event ID: %2 Description: %3

38060 880394ac 2 18060 Storage Cell: %1 Api Element Is Not Initialized Event ID: %2 Description: %3

38063 880394af 2 18063 Storage Cell: %1 Api Error trying to delete a disk group Event ID: %2 Description: %3

38065 880394b1 2 18065 Storage Cell: %1 Api A storage (Vdisk) operation is in progress. Try again later. Event ID: %2 Description: %3

38066 880394b2 2 18066 Storage Cell: %1 Api The storage (Vdisk) condition is invalid. The storage may be in error. Try again later. Event ID: %2 Description: %3

38067 880394b3 2 18067 Storage Cell: %1 Api Error calling get Vdisk condition. Vdisk may be deleted. Try again later. Event ID: %2 Description: %3

38068 880394b4 2 18068 Storage Cell: %1 Api Invalid initialization of the API. Cannot start monitoring process. Storage system management limited. Event ID: %2 Description: %3

38070 880394b6 2 18070 Storage Cell: %1 Api A command is currently under execution from another API call. Try again later. Event ID: %2 Description: %3

38071 880394b7 2 18071 Storage Cell: %1 Api The server has not completed initialization, cannot process the request. Event ID: %2 Description: %3

38073 880394b9 2 18073 Storage Cell: %1 Api Removal of disk from disk group successful Event ID: %2 Description: %3

38074 880394ba 2 18074 Storage Cell: %1 Api Disk(s) added to disk group successfully Event ID: %2 Description: %3

38075 880394bb 2 18075 Storage Cell: %1 Api Modify monitor properties successful Event ID: %2 Description: %3

38076 880394bc 2 18076 Storage Cell: %1 Api Element name too long. Maximum is 20 characters. Event ID: %2 Description: %3

38079 880394bf 2 18079 Storage Cell: %1 Api The basic license cannot be validated. Either the license key has not been entered, or there is a system communication failure. Event ID: %2 Description: %3

38080 880394c0 2 18080 Storage Cell: %1 Api The snapshot/Snapclone license cannot be validated. Either the license key has not been entered, or there is a system communication failure. Event ID: %2 Description: %3

38081 880394c1 2 18081 Storage Cell: %1 Api The folder operation is not valid for the specified folder. Either the folder is a root folder and cannot be modified, or it is a disk group folder for which you should use ‘Set Group’ command. Event ID: %2 Description: %3

38082 880394c2 2 18082 Storage Cell: %1 Api Cannot create the clone copy because the target storage is not presented. Event ID: %2 Description: %3

39001 88039859 3 19001 Storage Cell: %1 Storage Cell Lock Error Event ID: %2 Description: %3

Table 10: Command View EVA Event Codes: Management Agent Events (Continued)

Event ID Event CodeSev-erity

Evt. No. Description

Page 148: c00287657

Command View EVA event codes

148 Event code definitions application notes

39002 8803985a 2 19002 Storage Cell: %1 Storage Cell Deleted Event ID: %2 Description: %3

39003 8803985b 2 19003 Storage Cell: %1 An outstanding command is in-progress for the selected storage system. Please try again later. Event ID: %2 Description: %3

39004 8803985c 2 19004 Storage Cell: %1 Lock Wait Time too large Event ID: %2 Description: %3

39005 8803985d 2 19005 Storage Cell: %1 Place Request In Q Failed Event ID: %2 Description: %3

39006 8803985e 2 19006 Storage Cell: %1 No Match for Q Found Event ID: %2 Description: %3

39007 8803985f 2 19007 Storage Cell: %1 Agent Wait Timeout Event ID: %2 Description: %3

39008 88039860 3 19008 Storage Cell: %1 Free Lock Unsuccessful Event ID: %2 Description: %3

39009 88039861 3 19009 Storage Cell: %1 Lock Manager Mutex Timeout Error Event ID: %2 Description: %3

39010 88039862 6 19010 Storage Cell: %1 Lock Queue Memory Allocation Failure Event ID: %2 Description: %3

40001 88039c41 6 20001 Storage Cell: %1 LicMngr Memory Allocation Failure Event ID: %2 Description: %3

40002 88039c42 2 20002 Storage Cell: %1 LicMngr Startup Complete Event ID: %2 Description: %3

40003 88039c43 6 20003 Storage Cell: %1 LicMngr Startup Failed Event ID: %2 Description: %3

40004 88039c44 2 20004 Storage Cell: %1 License successfully checked out Event ID: %2 Description: %3

40005 88039c45 3 20005 Storage Cell: %1 License checkout failed Event ID: %2 Description: %3

40011 88039c4b 3 20011 Storage Cell: %1 License Line has an incorrect format Event ID: %2 Description: %3

40012 88039c4c 3 20012 Storage Cell: %1 License file with this Node WWID is missing Event ID: %2 Description: %3

40013 88039c4d 6 20013 Storage Cell: %1 License Library runtime error Event ID: %2 Description: %3

40014 88039c4e 6 20014 Storage Cell: %1 New License Job invocation failed Event ID: %2 Description: %3

40015 88039c4f 3 20015 Storage Cell: %1 Failed to retrieve Node WWN from storage system Event ID: %2 Description: %3

40016 88039c50 3 20016 Storage Cell: %1 Failed to retrieve license list from MLD Event ID: %2 Description: %3

40017 88039c51 3 20017 Storage Cell: %1 Failed to write license list to MLD Event ID: %2 Description: %3

40018 88039c52 3 20018 Storage Cell: %1 This license line appears to be invalid Event ID: %2 Description: %3

40019 88039c53 3 20019 Storage Cell: %1 MLD Manager Handle is NULL - unable to update MLD License List Event ID: %2 Description: %3

40020 88039c54 6 20020 Storage Cell: %1 LicMngr: Storage system handle is NULL Event ID: %2 Description: %3

40021 88039c55 2 20021 Storage Cell: %1 The license you entered is a valid license but not for the Node WWN on this controller pair Event ID: %2 Description: %3

40022 88039c56 2 20022 Storage Cell: %1 Function name string is null or in an incorrect format Event ID: %2 Description: %3

40023 88039c57 2 20023 Storage Cell: %1 Version string is null or in an incorrect format Event ID: %2 Description: %3

Table 10: Command View EVA Event Codes: Management Agent Events (Continued)

Event ID Event CodeSev-erity

Evt. No. Description

Page 149: c00287657

Command View EVA event codes

149Event code definitions application notes

41001 8803a029 2 21001 Storage Cell: %1 HSV Upgrade Manager Image File Open Error Event ID: %2 Description: %3

41002 8803a02a 2 21002 Storage Cell: %1 HSV Upgrade Manager Image File Buffer Allocation Error Event ID: %2 Description: %3

41003 8803a02b 2 21003 Storage Cell: %1 HSV Upgrade Manager Image File Read Error Event ID: %2 Description: %3

41004 8803a02c 2 21004 Storage Cell: %1 HSV Upgrade Manager Event File Write Error Event ID: %2 Description: %3

41005 8803a02d 2 21005 Storage Cell: %1 HSV Upgrade Manager Drive Firmware Update Failed Event ID: %2 Description: %3

41006 8803a02e 2 21006 Storage Cell: %1 HSV Upgrade Manager Global Header Edc Compute Error Event ID: %2 Description: %3

41007 8803a02f 2 21007 Storage Cell: %1 HSV Upgrade Manager Image Header Edc Compute Error Event ID: %2 Description: %3

41008 8803a030 2 21008 Storage Cell: %1 HSV Upgrade Manager Image Type Exceeds Max Image Count Event ID: %2 Description: %3

41009 8803a031 2 21009 Storage Cell: %1 HSV Upgrade Manager Image Type Not Controller Image Event ID: %2 Description: %3

41010 8803a032 2 21010 Storage Cell: %1 HSV Upgrade Manager Image Size Exceeded Event ID: %2 Description: %3

41011 8803a033 2 21011 Storage Cell: %1 HSV Upgrade Manager Event File Open Error Event ID: %2 Description: %3

41012 8803a034 2 21012 Storage Cell: %1 HSV Upgrade Manager Image Edc Compute Error Event ID: %2 Description: %3

41013 8803a035 2 21013 Storage Cell: %1 HSV Upgrade Manager Begin Text Not Found Event ID: %2 Description: %3

41014 8803a036 2 21014 Storage Cell: %1 HSV Upgrade Manager After Text Not Found Event ID: %2 Description: %3

41015 8803a037 2 21015 Storage Cell: %1 HSV Upgrade Manager File Format Version Mismatch Event ID: %2 Description: %3

41016 8803a038 2 21016 Storage Cell: %1 HSV Upgrade Manager Global Header Format Version Mismatch Event ID: %2 Description: %3

41017 8803a039 2 21017 Storage Cell: %1 HSV Upgrade Manager Product Information Was Not Found Event ID: %2 Description: %3

41018 8803a03a 2 21018 Storage Cell: %1 HSV Upgrade Manager Event File Was Not Found Event ID: %2 Description: %3

41019 8803a03b 2 21019 Storage Cell: %1 HSV Upgrade Manager All Images Match Versions Already Loaded Event ID: %2 Description: %3

42001 8803a411 3 22001 Storage Cell: %1 Trace: Unable to write management agent trace file Event ID: %2 Description: %3

42002 8803a412 2 22002 Storage Cell: %1 Trace: file write succeeded Event ID: %2 Description: %3

43002 8803a7fa 3 23002 Storage Cell: %1 Diagnostic The view list has errors Event ID: %2 Description: %3

43003 8803a7fb 6 23003 Storage Cell: %1 Diagnostic Memory allocation failure Event ID: %2 Description: %3

44001 8803abe1 2 24001 Storage Cell: %1 Windows system error Event ID: %2 Description: %3

Table 10: Command View EVA Event Codes: Management Agent Events (Continued)

Event ID Event CodeSev-erity

Evt. No. Description

Page 150: c00287657

Command View EVA event codes

150 Event code definitions application notes

44002 8803abe2 2 24002 Storage Cell: %1 Lock is already taken Event ID: %2 Description: %3

44003 8803abe3 2 24003 Storage Cell: %1 Lock is not taken Event ID: %2 Description: %3

44004 8803abe4 2 24004 Storage Cell: %1 Request timed out Event ID: %2 Description: %3

45001 8803afc9 2 25001 Storage Cell: %1 No path to controller Event ID: %2 Description: %3

45002 8803afca 2 25002 Storage Cell: %1 Thread is not running Event ID: %2 Description: %3

45003 8803afcb 2 25003 Storage Cell: %1 No physical stores Event ID: %2 Description: %3

45004 8803afcc 2 25004 Storage Cell: %1 Loop context ID changed Event ID: %2 Description: %3

45005 8803afcd 2 25005 Storage Cell: %1 Storage Cell context ID changed Event ID: %2 Description: %3

45006 8803afce 2 25006 Storage Cell: %1 Cache Write Failure Event ID: %2 Description: %3

45007 8803afcf 2 25007 Storage Cell: %1 Battery Disable Failure Event ID: %2 Description: %3

45008 8803afd0 2 25008 Storage Cell: %1 Drive Shelf Disable Failure Event ID: %2 Description: %3

45009 8803afd1 2 25009 Storage Cell: %1 Shutdown Both Restart And Power Off Requested Event ID: %2 Description: %3

45010 8803afd2 2 25010 Storage Cell: %1 Shutdown Drive Shelf Power Off But No Enclosure Power Off Requested Event ID: %2 Description: %3

45011 8803afd3 2 25011 Storage Cell: %1 Shutdown Disable Battery But No Enclosure Power Off Requested Event ID: %2 Description: %3

45012 8803afd4 2 25012 Storage Cell: %1 Shutdown Disable Battery But Shutdown Unconditional Requested Event ID: %2 Description: %3

45013 8803afd5 2 25013 Storage Cell: %1 Shutdown Delay Out Of Range Event ID: %2 Description: %3

45014 8803afd6 2 25014 Storage Cell: %1 Invalid Storage Cell name Event ID: %2 Description: %3

45015 8803afd7 2 25015 Storage Cell: %1 Requested spares goal cannot be satisfied Event ID: %2 Description: %3

45016 8803afd8 2 25016 Storage Cell: %1 No valid LDAD found Event ID: %2 Description: %3

45017 8803afd9 2 25017 Storage Cell: %1 Mismatched MLD size Event ID: %2 Description: %3

45018 8803afda 2 25018 Storage Cell: %1 Codeload image file error Event ID: %2 Description: %3

45019 8803afdb 2 25019 Storage Cell: %1 Storage System is not initialized Event ID: %2 Description: %3

46002 8803b3b2 2 26002 Storage Cell: %1 Invalid data replication operation Event ID: %2 Description: %3

46005 8803b3b5 2 26005 Storage Cell: %1 DR group name exceeds maximum length Event ID: %2 Description: %3

46006 8803b3b6 2 26006 Storage Cell: %1 DR group created successfully Event ID: %2 Description: %3

46007 8803b3b7 2 26007 Storage Cell: %1 Data replication invalid mode for DR Group create Event ID: %2 Description: %3

46008 8803b3b8 2 26008 Storage Cell: %1 Data replication duplicate group name Event ID: %2 Description: %3

46009 8803b3b9 2 26009 Storage Cell: %1 Data replication invalid operation while DR Groups exist Event ID: %2 Description: %3

46010 8803b3ba 2 26010 Storage Cell: %1 Data replication root folder does not exist Event ID: %2 Description: %3

46011 8803b3bb 2 26011 Storage Cell: %1 DR group discarded Event ID: %2 Description: %3

Table 10: Command View EVA Event Codes: Management Agent Events (Continued)

Event ID Event CodeSev-erity

Evt. No. Description

Page 151: c00287657

Command View EVA event codes

151Event code definitions application notes

46012 8803b3bc 2 26012 Storage Cell: %1 Data replication unknown remote storage system Event ID: %2 Description: %3

46013 8803b3bd 2 26013 Storage Cell: %1 Data replication Error. A conflicting Vdisk name exists on the remote storage system. Event ID: %2 Description: %3

46014 8803b3be 2 26014 Storage Cell: %1 Data Replication Error. Invalid Remote Vdisk Name specified. Event ID: %2 Description: %3

46015 8803b3bf 2 26015 Storage Cell: %1 Data Replication Error. Remote Vdisk size cannot be modified. Event ID: %2 Description: %3

46016 8803b3c0 2 26016 Storage Cell: %1 Data Replication Error. Remote Vdisk should be unpresented to proceed with the discard/detach operation. Event ID: %2 Description: %3

47001 8803b799 2 27001 Storage Cell: %1 The element manager has successfully initalized storage system. Command issued through XML Interface. Event ID: %2 Description: %3

47002 8803b79a 2 27002 Storage Cell: %1 The element manager has successfully created a virtual disk. Command issued through the XML Interface. Event ID: %2 Description: %3

47003 8803b79b 2 27003 Storage Cell: %1 The element manager has successfully created a disk group. Command issued through the XML Interface. Event ID: %2 Description: %3

47004 8803b79c 2 27004 Storage Cell: %1 The element manager has successfully created a DRM group. Command issued through the XML Interface. Event ID: %2 Description: %3

47005 8803b79d 2 27005 Storage Cell: %1 The element manager has successfully created a host. Command issued through the XML Interface. Event ID: %2 Description: %3

47006 8803b79e 2 27006 Storage Cell: %1 The element manager has successfully created a presented unit. Command issued through the XML Interface. Event ID: %2 Description: %3

47007 8803b79f 2 27007 Storage Cell: %1 The element manager has successfully created a virtual disk folder. Command issued through the XML Interface. Event ID: %2 Description: %3

47008 8803b7a0 2 27008 Storage Cell: %1 The element manager has successfully created a host folder. Command issued through the XML Interface. Event ID: %2 Description: %3

47009 8803b7a1 2 27009 Storage Cell: %1 The element manager has successfully created a disk group folder. Command issued through the XML Interface. Event ID: %2 Description: %3

47010 8803b7a2 2 27010 Storage Cell: %1 The element manager has successfully created a DRM group folder. Command issued through the XML Interface. Event ID: %2 Description: %3

47011 8803b7a3 2 27011 Storage Cell: %1 The element manager has successfully created a folder. Command issued through the XML Interface. Event ID: %2 Description: %3

47012 8803b7a4 2 27012 Storage Cell: %1 The element manager has successfully created a snapshot. Command issued through the XML Interface. Event ID: %2 Description: %3

47013 8803b7a5 2 27013 Storage Cell: %1 The element manager has successfully created a snapclone. Command issued through the XML Interface. Event ID: %2 Description: %3

47014 8803b7a6 2 27014 Storage Cell: %1 The element manager has successfully unitialized the storage system. Command issued through the XML Interface. Event ID: %2 Description: %3

47015 8803b7a7 2 27015 Storage Cell: %1 The element manager has successfully deleted a virtual disk. Command issued through the XML Interface. Event ID: %2 Description: %3

47016 8803b7a8 2 27016 Storage Cell: %1 The element manager has successfully deleted a disk group. Command issued through the XML Interface. Event ID: %2 Description: %3

Table 10: Command View EVA Event Codes: Management Agent Events (Continued)

Event ID Event CodeSev-erity

Evt. No. Description

Page 152: c00287657

Command View EVA event codes

152 Event code definitions application notes

47017 8803b7a9 2 27017 Storage Cell: %1 The element manager has successfully deleted a DRM group. Command issued through the XML Interface. Event ID: %2 Description: %3

47018 8803b7aa 2 27018 Storage Cell: %1 The element manager has successfully deleted a host. Command issued through the XML Interface. Event ID: %2 Description: %3

47019 8803b7ab 2 27019 Storage Cell: %1 The element manager has successfully deleted a presented unit. Command issued through the XML Interface. Event ID: %2 Description: %3

47020 8803b7ac 2 27020 Storage Cell: %1 The element manager has successfully deleted a virtual disk folder. Command issued through the XML Interface. Event ID: %2 Description: %3

47021 8803b7ad 2 27021 Storage Cell: %1 The element manager has successfully deleted a host folder. Command issued through the XML Interface. Event ID: %2 Description: %3

47022 8803b7ae 2 27022 Storage Cell: %1 The element manager has successfully deleted a disk group folder. Command issued through the XML Interface. Event ID: %2 Description: %3

47023 8803b7af 2 27023 Storage Cell: %1 The element manager has successfully deleted a DRM group folder. Command issued through the XML Interface. Event ID: %2 Description: %3

47024 8803b7b0 2 27024 Storage Cell: %1 The element manager has successfully deleted a folder. Command issued through the XML Interface. Event ID: %2 Description: %3

47025 8803b7b1 2 27025 Storage Cell: %1 The element manager has successfully deleted a snapshot. Command issued through the XML Interface. Event ID: %2 Description: %3

47026 8803b7b2 2 27026 Storage Cell: %1 The element manager has successfully modified the properties of a storage system. Command issued through the XML Interface. Event ID: %2 Description: %3

47027 8803b7b3 2 27027 Storage Cell: %1 The element manager has successfully modified the properties of a virtual disk. Command issued through the XML Interface. Event ID: %2 Description: %3

47028 8803b7b4 2 27028 Storage Cell: %1 The element manager has successfully modified the properties of a disk group. Command issued through the XML Interface. Event ID: %2 Description: %3

47029 8803b7b5 2 27029 Storage Cell: %1 The element manager has successfully modified the properties of a DRM group. Command issued through the XML Interface. Event ID: %2 Description: %3

47030 8803b7b6 2 27030 Storage Cell: %1 The element manager has successfully modified the properties of a host. Command issued through the XML Interface. Event ID: %2 Description: %3

47031 8803b7b7 2 27031 Storage Cell: %1 The element manager has successfully modified the properties of a presented unit. Command issued through the XML Interface. Event ID: %2 Description: %3

47032 8803b7b8 2 27032 Storage Cell: %1 The element manager has successfully modified the properties of a virtual disk folder. Command issued through the XML Interface. Event ID: %2 Description: %3

47033 8803b7b9 2 27033 Storage Cell: %1 The element manager has successfully modified the properties of a host folder. Command issued through the XML Interface. Event ID: %2 Description: %3

Table 10: Command View EVA Event Codes: Management Agent Events (Continued)

Event ID Event CodeSev-erity

Evt. No. Description

Page 153: c00287657

Command View EVA event codes

153Event code definitions application notes

47034 8803b7ba 2 27034 Storage Cell: %1 The element manager has successfully modified the properties of a hardware root folder. Command issued through the XML Interface. Event ID: %2 Description: %3

47035 8803b7bb 2 27035 Storage Cell: %1 The element manager has successfully modified the properties of a disk group folder. Command issued through the XML Interface. Event ID: %2 Description: %3

47036 8803b7bc 2 27036 Storage Cell: %1 The element manager has successfully modified the properties of a DRM group folder. Command issued through the XML Interface. Event ID: %2 Description: %3

47037 8803b7bd 2 27037 Storage Cell: %1 The element manager has successfully modified the properties of a DRM group root folder. Command issued through the XML Interface. Event ID: %2 Description: %3

47038 8803b7be 2 27038 Storage Cell: %1 The element manager has successfully modified the properties of a folder. Command issued through the XML Interface. Event ID: %2 Description: %3

47039 8803b7bf 2 27039 Storage Cell: %1 The element manager has successfully modified the properties of a snapshot. Command issued through the XML Interface. Event ID: %2 Description: %3

47040 8803b7c0 2 27040 Storage Cell: %1 The element manager has successfully modified the properties of a disk. Command issued through the XML Interface. Event ID: %2 Description: %3

47041 8803b7c1 2 27041 Storage Cell: %1 The element manager has successfully modified the properties of a disk shelf. Command issued through the XML Interface. Event ID: %2 Description: %3

47042 8803b7c2 2 27042 Storage Cell: %1 The element manager has successfully modified the properties of a controller. Command issued through the XML Interface. Event ID: %2 Description: %3

47043 8803b7c3 2 27043 Storage Cell: %1 The element manager has successfully modified the properties of a controller shelf. Command issued through the XML Interface. Event ID: %2 Description: %3

47044 8803b7c4 2 27044 Storage Cell: %1 The element manager has successfully modified the properties of a cabinet. Command issued through the XML Interface. Event ID: %2 Description: %3

47045 8803b7c5 2 27045 Storage Cell: %1 The element manager has successfully reserved an object. Command issued through the XML Interface. Event ID: %2 Description: %3

47046 8803b7c6 2 27046 Storage Cell: %1 The element manager has successfully released an object. Command issued through the XML Interface. Event ID: %2 Description: %3

47047 8803b7c7 2 27047 Storage Cell: %1 XML cache mutex timeout. Event ID: %2 Description: %3

47048 8803b7c8 2 27048 Storage Cell: %1 XML cache memory allocation error. Event ID: %2 Description: %3

47049 8803b7c9 2 27049 Storage Cell: %1 XML subsystem unknown error. Event ID: %2 Description: %3

Table 10: Command View EVA Event Codes: Management Agent Events (Continued)

Event ID Event CodeSev-erity

Evt. No. Description

Page 154: c00287657

Command View EVA event codes

154 Event code definitions application notes