BRUCKER COMPANY STOCK CATALOG
Stock Catalog
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
Elk Grove Village1200 Greenleaf Avenue
Elk Grove Village, IL 60007Tel: (847) 437-9690Fax: (847) 437-0741
Peoria7700 North Harker Dr., Suite B
Peoria, IL 61615Tel: (309) 691-5160Fax: (309) 691-6437
www.bruckerco.com• Order stock online• Check order status• View Manufacturer Data
to get the job done NOW.We have the materials you need
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
ABB, lnc.www.abb.us/drives com• Adjustable frequency drives
for fans, pumps, and cool-ing towers
• Control products
Air Concepts www.airconceptsinc.com• Punkah louvers/drum
louvers •Air nozzles
Air Flow Technologywww.airflowtechnology.com• Medium to high efficiency
synthetic filters • Custom autobody & indus-
trial filtration products
Buckley Air Products, Inc.wwwbuckleyonline.com• Duct fittings • Bellmouth fittings • Transitions
Cameron Great Lakeswww.cglcarbon.com• Gas phase filters • Impregnated carbons
Cerus Industrialwww.cerusindustrial.com • Starters
Cloud 9www.4cloud9.com• Air purifying systems
Data-Aire, Inc.www.dalaaire.com• Computer room air condi-
tioners • Computer room chillers
FabricAirwww.fabricair com • Fabric ducts
Greenheck Fan Corporationwww.greenheck com• Power roof ventilators• Panel propeller fans• Vane axial fans• Centrifugal fans• Make-up air systems• Kitchen exhaust hoods• Fire and smoke dampers• Louvers, control dampers• Energy recovery ventilators• Laboratory exhaust
Howden Fanswww.howdenbuffalo.com Buffalo Division • Industrial duty fansJoy Fan Division • Vane axial fans
Indeecowww.indeeco.com• Electric open coil duct heat-
ers• Electric boilers• Finned tubular duct heaters
Industrial Acoustics Co. www.industrialacoustics.com• Duct silencers, acoustical
plenum and louvers
Islandaire www.lslandalrecom• Packaged terminal air con-
ditioning units
Kees, Inc.www.kees.com• Sheet Metal Specialties
Price Industrieswww.price-hvac.com• Grilles, registers, diffusers• VAV terminals• Fan powered terminals In-
dustrial grilles and diffusers• Hospital operating room
systems• Clean room systems• Unilee ceiling systems• Sound attenuators
Purolator Products Co.www.purolatorair.com• Air filters - basic, medium,
and high efficiency • Filter housings
Q-Markwww.qmarkmeh.com• Electric unit healers• Ceiling and wall heaters• Baseboard and pedestal
heaters
Resylutionwww.resylution.com• Prefabricated mechanical
rooms• Chillers, pumps, lowers,
molar control centers
Smithwww.smithfilter.com• Air and grease fitters and
accessories
Spunstrandwww.spunstrand.com• FSK underslab air duct • Fiberglass fume exhaust
StrionAirwww.strionair.com• Germicidal, high efficiency,
low pressure air filtration systems
Trionwww.trioninc.com• Specialty filtered products
Vent Productswww.ventprod.com• Louvers, control dampers• Louvered penthouses• Fire and smoke dampers• Curb equipment supports
Viron Internationalwww.vironintl.com• FRP & PVC fans, duct work
& hoods• Scrubbers• Coated stainless duct
WaterFurnacewww.waterfurnace.com• Water source heat pumps• Geothermal systems
Winkler Manufacturing •Blast gates
Young Regulator Companywww.youngregulator.com• Manual dampers• Motorized dampers• Remote control dampers &
controllers
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
TABL
E OF
CON
TENT
S
TABLE OF CONTENTS
GreenheckCentrifugal Roof Exhaust Direct Drive – G 2Centrifugal Roof Exhaust Belt Drive – GB 4Upblast Roof Exhaust Direct Drive – CUBE 8Sidewall Exhaust Direct Drive – CWB 11Ceiling Exhaust Fans – SP 12Inline Cabinet Exhaust Fans – CSP 14Roof & Wall Discharge Accessories 16Inline Fans – Direct Drive and Belt Drive – SQ/BSQ 18Sidewall Propeller Fan – Direct Drive – SE 21Sidewall Propeller Fan – Belt Drive – SBE 23Sidewall Fan Accessories – SE/SBE 25Gravity Ventilators – GRS 26Centrifugal Utility Fans – SFB 27Centrifugal Utility Fans – SWB 28Ceiling Radiation Dampers 30Dynamic Fire dampers – DFD-150/DFDR-510 30Backdraft Dampers, Curbs & Equipment Supports 31ABBVariable Frequency Drives 34Model UH Base Drive 35Model VCR Vertical Bypass with Circuit Breaker 36
BrOAnBath Fans 38Ventilation Fans - Ultra Silent™ 39Combination Units 40Wall Heaters 41LoSone Ventilators 42Broan Controls 43Roof and Wall Caps 44
Price industriesFixed Blade Return Grilles and Registers Model 530 and 530D 46Filter Return Grilles Model 530FF 47Light Shields 47Round Diffusers Model RCDE 49Door/Transfer Grilles Model STG1 50Double Deflection Supply Grilles Model 520D & Single Deflection Supply Grilles Model VM 51High Capacity Drum Louvers Model HCD1D 56Square Cone Diffusers Model SCD/Plaster Frames 57Square Cone Diffusers Model SCDA Adjustable Air Pattern/Plaster Frames 59Square Plaque Diffusers Model SPD/Plaster Frames 61 Linear Slot Diffuser Model SDS 63Linear Slot Diffuser Plenums Model SDBI 64Price industries (continued)
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
TABLE OF CONTENTS (continued)
T-Bar Supply Diffusers Model TBDI4 65Perforated Supply Diffusers Model PDF/PDFE 67Perforated Return Diffusers Model PDDR/PDDRE (Matching Return for PDF/PDFE) 70Dampers 72Spiral Duct Mount Grilles Model SDG 73Louvered Face Diffusers Model SMD 73Egg Crate Grilles Model 80/Plaster Frames 75Round Neck Adaptors Model SR3 77Single Duct – Controller Type SPV, SDV, SEV Series 78Control Sequence Model SPV/SEV 82VAV Diffuser Varitherm® Model VPD-HC 83
reliABle PrOductsFloor Diffusers 86
Access dOOrsAccess Doors – Hinged or Double Catch Lock 88
FlexiBle technOlOGies, triAnGle MAnuFActurinGFlexible Tubing 90Locking Ties 90
Q’MArk, leAdinG edGe & therMOstAtsUnit Heaters Type MUH 92Architectural Heavy-Duty Wall Heaters — Type AWH-4000 94Commercial Wall Heaters – Fan-Forced — Type CWH-1000 95Commercial Wall Heaters – Fan-Forced — Type CWH-3000 96Ceiling Mounted Heaters – Fan-Forced — Type QCH 97Electric Baseboard Heaters — Type 2500 97Commercial Downflow Ceiling Mounted Heaters — Type CDF 98Heat Recovery Ceiling Fans (Leading Edge) 99Thermostats 101
MiscellAneOus suPPlies And PrOductsVibration Isolators 104Motors 105
YOunG reGulAtOrsDampers and Controls 108Remote Cable Controls 108Socket Wrench 108Casing and Wire 108
cerus industriAlMotor Starters – Model BAS 110Motor Starters – Model BAS-1P 110
PurOlAtOrhi-E 40™ Pleated Filter 112Defiant® Mark 80D™ Pleat 113
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 1
GREE
NHEC
K
GREENHECK
Centrifugal Roof Exhaust Direct Drive – G 2
Centrifugal Roof Exhaust Belt Drive – GB 4
Upblast Roof Exhaust Direct Drive – CUBE 8
Sidewall Exhaust Direct Drive – CWB 11
Ceiling Exhaust Fans – SP 12
Inline Cabinet Exhaust Fans – CSP 14
Roof & Wall Discharge Accessories 16
Inline Fans – Direct Drive and Belt Drive – SQ/BSQ 18
Sidewall Propeller Fan – Direct Drive – SE 21
Sidewall Propeller Fan – Belt Drive – SBE 23
Sidewall Fan Accessories – SE/SBE 25
Gravity Ventilators – GRS 26
Centrifugal Utility Fans – SFB 27
Centrifugal Utility Fans – SWB 28
Ceiling Radiation Dampers 30
Dynamic Fire Dampers – DFD-150/DFDR-510 30
Backdraft Dampers, Curbs & Equipment Supports 31
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com2
MODEL A B C* ROOFOPENING
DAMPER SIZE
IN STOCK SIZES (n)
MIN/MAX RPM
SONES @ 0 in.
PERFORMANCE IN INCHES WG0 .125 .25 .5 .75 1
G-060 17 193/8 121/8 101/2 x 101/2
8 x 8
n1050 1.7 138 731550 4.2 203 166 120
G-065 17 193/8 121/8 101/2 x 101/2 n1050 2.2 187 1101550 4.9 276 232 176
G-070 17 193/8 121/8 101/2 x 101/2 n1050 2.7 254 1791550 5.6 374 327 274
G-075 17 193/8 121/8 101/2 x 101/2 n1050 3.6 296 2001550 6.1 438 377 310
G-080 17 213/4 145/8 121/2 x 121/2
10 x 10
n1050 3.8 335 249 1341550 7.3 495 439 379 238
G-085 17 213/4 145/8 121/2 x 121/2 n1050 4.0 399 307 1791550 7.6 588 529 464 308
G-090 17 213/4 145/8 121/2 x 121/2 n1050 4.0 520 420 2921550 7.6 768 700 633 472
G-095 17 213/4 145/8 121/2 x 121/2 n1050 5.4 717 569 3891550 9.6 1059 969 863 623
G-103 19 245/8 20 141/2 x 141/2
12 x 12
n860 4.3 766 588 2391725 12.1 1536 1454 1374 1181 974
G-123 19 245/8 20 141/2 x 141/2 n860 5.6 922 723 4491725 14.1 1849 1753 1659 1453 1223
G-133 19 245/8 20 141/2 x 141/2 n860 6.5 1193 1011 7711725 19.2 2393 2310 2222 2030 1820 1555
G-143 22 287/8 20 181/2 x 181/2
16 x 16
n860 6.8 1376 1160 9191140 10.4 1824 1667 1498 1112
G-150 26 351/2 211/8 181/2 x 181/2 n860 7.9 1772 1552 13051140 11.7 2348 2184 2016 1629 1115
G-163 22 287/8 20 181/2 x 181/2 n860 8.0 2008 1783 1535 5521140 13.6 2662 2489 2319 1932 1411
Centrifugal Roof Exhaust Direct Drive - GModel G Centrifugal Roof Exhaust fans are direct drive. These fans are specifically designed for roof mounted applications exhausting relatively clean air. Fan wheels are centrifugal, backward inclined, and constructed of aluminum.
For complete product information contact your Brucker sales representative.
Greenheck Fan Corporation certifies that the G models shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
*May be greater depending on motor. All dimensions in inches.Dimension A - given is the inside dimensions of the curb cap. The roof curb should be 11/2 in. less than the curb cap to allow for roofing and flashing. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
A
B
C
13/4 in.
*
UL/cUL 705 E40001 - G
G Condensed PerformanCe & dimensional data
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 3
GREE
NHEC
K
Centrifugal Roof Exhaust Direct Drive - GOPTiOnS AnD ACCESSORiES • Gravity and motorized dampers• Galvanized roof curbs• Speed controls
STAnDARD COnSTRUCTiOn FEATURES• Aluminum housing • non-overloading backward inclined wheel • Aluminum curb cap with prepunched mounting holes • integral reinforced bead for strength on hood • Galvanized birdscreen • Ball bearing motors (sizes 101-180), sleeve bearing motors (sizes 060-095) • Motor isolated on shock mounts • Corrosion resistant fasteners • nema-1 disconnect• UL/cUL 705 Electrical
MODEL RPM TS SONES @ 0 in.
MAXBHP
PRESSURE IN INCHES WG0 .125 .25 .375 .5 .625 .75
G-060-DGEX1/60 HP3 Speed
E 1050 2234 1.7 .005 138 73G 1300 2765 2.9 .009 170 125D 1550 3297 4.2 .016 203 166 120
G-065-DGEX1/30 HP3 Speed
E 1050 2234 2.2 .007 187 110G 1300 2765 3.2 .012 231 178 91D 1550 3297 4.9 .022 276 232 176 96
G-070-DGEX1/30 HP3 Speed
E 1050 2234 2.7 .008 254 179G 1300 2765 4.1 .015 314 257 171D 1550 3297 5.6 .026 374 327 274 190
G-075-DGEX1/25 HP3 Speed
E 1050 2234 3.6 .011 296 200G 1300 2765 4.1 .021 367 294 195D 1550 3297 6.1 .035 438 377 310 214
G-080-DGEX1/20 HP3 Speed
E 1050 2990 3.8 .017 335 249 134G 1300 3701 5.4 .033 415 348 272 175D 1550 4413 7.3 .057 495 439 379 314 238
G-085-DGEX1/20 HP3 Speed
E 1050 2990 4.0 .019 399 307 179G 1300 3701 5.5 .036 494 421 340 233D 1550 4413 7.6 .062 588 529 464 393 308 169
G-090-DGEX1/15 HP3 Speed
E 1050 2990 4.0 .024 520 420 292G 1300 3701 5.4 .045 644 564 478 373D 1550 4413 7.6 .076 768 700 633 558 472 338
G-095-DGEX1/8 HP
3 Speed
E 1050 2990 5.4 .037 717 569 389G 1300 3701 7.6 .071 888 780 640 493 184D 1550 4413 9.6 .120 1059 969 863 745 623 474
G-103-CX1/8 HP 860 2632 4.2 .02 766 588
G-103-BX1/6 HP 1140 3488 7.1 .06 1015 893 747 568
G-103-AX1/4 HP 1725 5278 12.1 .22 1536 1454 1374 1277 1181 1086 974
G-123-CX1/8 HP 860 2800 5.4 .03 922 723 450
G-123-BX1/6 HP 1140 3712 8.1 .09 1222 1078 918 734 335
G-123-AX1/4 HP 1725 5617 14.1 .30 1849 1753 1659 1560 1453 1341 1223
G-133-CX1/8 HP 860 3138 6.1 .04 1193 1011 771 600
G-133-BX1/6 HP 1140 4160 9.9 .13 1581 1452 1303 1129 889 381
G-143-CX1/8 HP 860 3293 6.8 .074 1376 1161 919 489
G-143-BX1/6 HP 1140 4365 10.4 .17 1824 1667 1498 1313 1112 794
G-150-CX1/8 HP 860 3602 7.9 .10 1772 1552 1305 1006
G-150-BX1/4 HP 1140 4775 11.7 .29 2348 2184 2016 1837 1629 1398 1115
G-163-BX1/3 HP 1140 4887 13.6 .32 2662 2489 2319 2135 1932 1697 1411
G PerformanCe data - in stoCkin stock sizes include
birdscreen, disconnect switch, UL/cUL 705 electrical.
Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com4
A
B
C*
13/4 in.
*May be greater depending on motor. All dimensions in inches. Dimension A - given is the inside dimensions of the curb cap.The roof curb should be 11/2 in. less than the curb cap to allow for roofing and flashing. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
GB Condensed PerformanCe ranGes & dimensional data
UL/cUL 705E40001 - GB
MODEL A B C* ROOFOPENING
DAMPER SIZE
IN STOCK SIZES (n)
MIN/MAX RPM
SONES @ 0 in.
PERFORMANCE IN INCHES WG0 .25 .5 .75 1 1.25 1.5 1.75 2.0
GB-071 19 243/8 233/4 141/2 x 141/2
12 x 12
n 600 1.2 131 68
1710 11.1 372 334 292 245 198
GB-081 19 243/8 233/4 141/2 x 141/2 n600 2.2 301 175
1710 12.5 856 784 710 629 480
GB-091 19 243/8 233/4 141/2 x 141/2 n600 2.7 455 271
1710 13.4 1295 1179 1061 934 785
GB-101 19 243/8 233/4 141/2 x 141/2 n700 3.7 593 455
1800 13.2 1525 1418 1320 1208 1064 793
GB-121 19 243/8 233/4 141/2 x 141/2 n595 3.3 721
1725 17.4 2093 1984 1871 1743 1600 1426
GB-131 19 283/8 233/4 141/2 x 141/2 n595 4.5 844 655
1685 16.9 2391 2278 2157 2020 1857 1654
GB-141 22 283/8 233/4 181/2 x 181/216 x 16
n525 4.4 974 709
1705 20 3163 3020 2883 2739 2574 2370
GB-161 22 283/8 233/4 181/2 x 181/2 n478 4.7 1412 1030
1375 21 4062 3815 3571 3304 3007 2609 2073
GB-180 30 351/2 28 201/2 x 201/218 x 18
n495 4.3 1924 1150
1460 26 5677 5514 5335 5155 4938 4698 4426 4123 3765
GB-200 30 351/2 28 201/2 x 201/2 n440 6.5 2434
1200 24 6640 6336 5968 5650 5274 4828 4177 3077
GB-220 34 423/4 311/2 261/2 x 261/224 x 24
n330 6.6 2507985 23 7484 7212 6898 6568 6106 5547 4883
GB-240 34 423/4 311/2 261/2 x 261/2 n425 5.9 3902 3422 2691910 24 8355 7916 7467 6932 6240 5388 3707
GB-260 40 50 36 321/2 x 321/230 x 30
270 7.7 3487835 23 10784 10292 9794 9225 8606 7932 7157 6024 4294
GB-300 40 50 36 321/2 x 321/2 n300 9.3 4859 3976890 28 14416 13897 13335 12716 12072 11379 10536 9568 7963
GB-330 46 583/4 381/2 381/2 x 381/236 x 36
255 5.2 6159700 28 16908 16185 15408 14564 13624 12640 11538 10184
GB-360 46 583/4 381/2 381/2 x 381/2 n215 4.8 5750685 30 18321 17560 16711 15773 14710 13534 12119
For complete product information contact your Brucker sales representative.
Greenheck Fan Corporation certifies that the G models shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
Centrifugal Roof Exhaust Belt Drive - GBModel GB Centrifugal Roof Exhaust fans are belt drive. These fans are specifically designed for roof mounted applications exhausting relatively clean air. Fan wheels are centrifugal, backward inclined, and constructed of aluminum. Adjustable motor pulleys allow for final system balancing.
*May be greater depending on motor. All dimensions in inches. Dimension A - given is the inside dimensions of the curb cap.The roof curb should be 11/2 in. less than the curb cap to allow for roofing and flashing. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 5
GREE
NHEC
K
Centrifugal Roof Exhaust Belt Drive - GBOPTiOnS AnD ACCESSORiES • Gravity and motorized dampers• Galvanized roof curbs
STAnDARD COnSTRUCTiOn FEATURES• Aluminum housing• non-overloading backward inclined wheel• Galvanized birdscreen• integral reinforcing bead for strength• Double studded isolators for true vibration isolation• Motor out of airstream• Motor pulley is adjustable for system balancing• nema-1 disconnect• Lifting lugs (mid and larger sizes)• UL/cUL 705 Electrical
Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
GB PerformanCe data - in stoCk Stock Model GB fans include galvanized birdscreen, disconnect switch, UL/cUL 705 Electrical.
MODEL HP RPM TS SONES @ 0 IN.
MAX BHP
PERFORMANCE IN INCHES WG
0 .125 .25 .375 .5 .625 .75 1
GB-071-4X-R31221-1710 RPM
1/4 HP, 115/60/1 ODP1/4
1247 3652 6.5 0.05 272 246 217 185 154 109
1556 4558 9.3 0.098 339 319 296 274 248 223 197 120
1710 5009 11.1 0.13 373 353 335 312 292 269 246 198
GB-081-4X-R31221-1710 RPM
1/4 HP, 115/60/1 ODP1/4
1247 3652 7.6 0.073 625 575 525 470 403 284
1556 4558 10.8 0.14 779 740 700 660 615 571 517
1710 5009 12.5 0.19 856 821 785 748 710 669 630 511
GB-091-4X-R31221-1710 RPM
1/4 HP, 115/60/1 ODP1/4
1247 3652 9.2 0.098 945 866 785 698 604 454
1556 4558 11.8 0.19 1179 1116 1052 988 919 848 772 504
1710 5009 13.4 0.25 1296 1238 1180 1122 1062 999 934 785
GB-101-4X-R41324-1688 RPM
1/4 HP, 115/60/1 ODP
GB-101-3X1635-1800 RPM
1/3 HP, 115/60/1 ODP
1/41400 4077 8.9 0.16 1186 1117 1051 989 909 810 633
1635 4761 11.1 0.25 1385 1325 1269 1214 1161 1094 1019 792
1/3 1800 5242 13.2 0.33 1525 1471 1418 1367 1320 1270 1208 1064
GB-121-4X980-1395 RPM
1/4 HP, 115/60/1 ODP
GB-121-5X1550-1725 RPM
1/2 HP, 115/60/1 ODP
1/4
595 2035 3.3 0.021 722 542
820 2804 5.2 0.054 995 877 728
1045 3574 7.3 0.111 1268 1177 1078 962 805
1395 4770 12.5 0.25 1692 1625 1557 1484 1404 1315 1214 907
1/21550 5300 14.6 0.33 1880 1820 1759 1696 1629 1555 1475 1289
1725 5899 17.4 0.50 2093 2038 1984 1928 1871 1810 1743 1600
GB-131-4X942-1315 RPM
1/4 HP, 115/60/1 ODP
GB-131-5X1299-1685 RPM
1/2 HP, 115/208-230/60/1
ODP
1/4
595 2044 4.5 0.024 844 655
720 2474 5.4 0.043 1022 879 650
960 3299 7.6 0.103 1362 1262 1144 990
1315 4518 13.2 0.26 1866 1794 1718 1637 1545 1435 1305
1/21440 4948 15.0 0.35 2044 1978 1911 1838 1759 1674 1571 1299
1685 5790 16.9 0.56 2391 2335 2279 2219 2158 2093 2020 1857
GB-141-4X614-865 RPM
1/4 HP, 115/60/1 ODP
GB-141-3X906-1170 RPM
1/3 HP, 115/60/1 ODP
GB-141-5X1049-1360 RPM1/2 HP, 115/208-
230/60/1 ODP
1/4
525 2010 4.4 0.030 974 709
710 2718 5.7 0.074 1317 1147 908
920 3522 7.7 0.16 1706 1576 1439 1258 961
1075 4115 10.0 0.26 1994 1881 1771 1646 1489 1265
1/3 1170 4479 11.4 0.34 2170 2066 1966 1858 1733 1574 1355
1/2 1360 5207 14.6 0.53 2522 2433 2346 2258 2166 2062 1942 1602
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com6
Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
MODEL HP RPM TS SONES @ 0 IN.
MAX BHP
PERFORMANCE IN INCHES WG
0 .125 .25 .375 .5 .625 .75 1 1.5 2
GB-161-LMDX425-1375 RPM
1/4
478 2080 4.7 0.044 1412 1030
625 2720 6.4 0.097 1846 1574 1221
865 3764 10.6 0.26 2555 2359 2162 1932 1624
1/3 945 4113 12.6 0.34 2791 2612 2433 2236 2009 1692
1/2 1100 4787 15.3 0.53 3249 3094 2943 2786 2614 2428 2197
3/4 1250 5440 17.9 0.79 3692 3556 3421 3288 3149 2997 2838 2443
1 1375 5984 21 1.05 4062 3938 3815 3694 3571 3444 3304 3007 2073
GB-180-LMDX495-1460 RPM
1/4495 2397 4.3 0.078 1924 1645 1150
730 3535 7.4 0.26 2838 2667 2469 2212 1882
1/3 810 3923 8.8 0.35 3149 2997 2832 2623 2375 2052
1/2 940 4552 12.7 0.55 3655 3526 3387 3234 3052 2843 2600
3/4 1055 5109 16.2 0.77 4102 3989 3866 3741 3596 3432 3251 2811
1 1185 5739 19.0 1.1 4607 4507 4400 4290 4179 4045 3900 3575
11/2 1335 6465 22 1.54 5191 5102 5010 4912 4814 4715 4599 4343
2 1460 7071 26 1.97 5677 5595 5514 5424 5335 5245 5155 4938 4426 3765
GB-200-LMDX440-1200 RPM
1/4440 2462 6.5 0.103 2434 1975
600 3357 8.5 0.26 3320 2984 2637 2088
1/3 665 3721 9.6 0.35 3679 3378 3084 2705 2087
1/2 770 4308 12.1 0.55 4260 4013 3744 3477 3140 2643
3/4 860 4812 14.1 0.77 4759 4548 4289 4068 3810 3504 3085
1 965 5400 16.7 1.09 5340 5157 4927 4719 4519 4285 4015 3239
11/2 1090 6099 20 1.57 6031 5870 5681 5473 5301 5123 4924 4449
2 1200 6715 24 2.09 6640 6493 6336 6144 5968 5812 5650 5274 4177
GB-220-LMDX425-985 RPM
1/4425 2670 7.4 .16 3230 2879 2296
505 3168 8.9 .27 3837 3553 3183 2608
1/3 550 3455 10 .3 4179 3924 3629 3158 2525
1/2 640 4021 13 .48 4863 4653 4403 4119 3702 3208
3/4 710 4461 15 .65 5395 5206 4990 4761 4458 4076 3633
1 800 5026 16.6 .93 6079 5911 5731 5529 5326 5049 4716 3929
11/2 895 5623 19.4 1.31 6800 6651 6501 6322 6141 5959 5722 5121
2 985 6188 23 1.74 7484 7348 7212 7062 6898 6733 6568 6106 4883
GB-240-LMDX300-910 RPM
1/4425 2726 5.9 0.21 3902 3422 2691
460 2950 6.7 0.26 4223 3784 3188 2036
1/3 505 3239 7.8 0.35 4636 4241 3760 3059
1/2 585 3752 10.3 0.55 5371 5030 4665 4194 3562 2112
3/4 660 4233 13.1 0.79 6059 5756 5449 5093 4636 4073 3217
1 730 4682 15.8 1.06 6702 6427 6157 5861 5506 5076 4567
11/2 825 5291 19.7 1.54 7574 7331 7091 6844 6573 6261 5901 5002
2 910 5836 24 2.06 8355 8134 7916 7699 7467 7214 6932 6240 3707
5 890 7106 28 5.05 14416 14157 13897 13638 13335 13027 12716 12072 10536 7963
GB PerformanCe data - in stoCk Stock Model GB fans include galvanized birdscreen, disconnect switch, UL/cUL 705 Electrical.
Centrifugal Roof Exhaust Belt Drive - GB
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 7
GREE
NHEC
K
MODEL HP RPM TS SONES @ 0 IN.
MAX BHP
PERFORMANCE IN INCHES WG
0 .125 .25 .375 .5 .625 .75 1 1.5 2
GB-300-LMDX250-890 RPM
1/3300 2395 9.3 0.19 4859 3976
365 2914 9.2 0.35 5912 5222 4339
1/2 420 3353 9.6 0.53 6803 6221 5536 4640
3/4 475 3792 11.4 0.77 7694 7197 6615 5954 5094
1 530 4231 13.4 1.07 8584 8149 7639 7094 6455 5667 4194
1 1/2 600 4790 15.9 1.55 9718 9334 8906 8445 7951 7387 6721
2 665 5309 18.8 2.12 10771 10424 10059 9648 9228 8772 8268 7025
GB-360-LMDX335-685 RPM
1/2 335 3157 9.1 0.59 8960 3131 7100 5611
3/4 365 340 10.8 0.72 9762 9024 8109 7012
1 410 3864 13.7 1.02 10966 10329 9558 8685 7640
1 1/2 460 4335 15.9 1.45 12303 11736 11085 10359 9567 8607 7096
2 505 4759 18.1 1.91 13507 12990 12430 11794 11095 10367 9472
3 580 5466 22 2.9 15513 15063 14613 14076 13522 12917 12289 10812
5 685 6455 30 4.77 18321 17940 17560 17179 16711 16242 15773 14710 12119
GB Performance data - in stock Stock Model GB fans include galvanized birdscreen, disconnect switch, UL/cUL 705 Electrical.
Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
Centrifugal Roof Exhaust Belt Drive - GB
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com8
B
C*D
A
13/4 in.
Greenheck Fan Corporation certifies that the CUBE models shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
*May be greater depending on motor. All dimensions in inches.^Dampers should not be used in grease applications.Dimension A - given is the inside dimensions of the curb cap.The roof curb should be 11/2 in. less than the curb cap to allow for roofing and flashing.Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
CUBe Condensed PerformanCe ranGes & dimensional data
UL/cUL 705UL/cUL 762MH 11745-CUBE
MODEL A B C* D ROOF OPENING
DAMPER SIZE^
IN STOCK SIZES (n)
MIN/MAX RPM
SONES @ 0 IN.
PERFORMANCE IN INCHES WG0 .25 .5 .75 1 2
CUBE-101 19 247/8 281/4 173/8 141/2 x 141/2
12 x 12
n860 4.6 732 625 481
1820 14.3 1549 1459 1350 1234 1106
CUBE-121 19 247/8 281/4 173/8 141/2 x 141/2 n685 4.4 809
1725 15.6 2037 1923 1816 1710 1571
CUBE-131 19 247/8 281/4 173/8 141/2 x 141/2650 6.2 892
1645 17.9 2256 2128 2001 1864 1684
CUBE-141 22 293/4 243/4 193/8 181/2 x 181/216 x 16
n590 5.0 1069
1725 26 3125 3005 2865 2711 2539
CUBE-161 22 293/4 243/4 193/8 181/2 x 181/2 n730 8.1 2098 16691390 22 3996 3806 3584 3340 3078
CUBE-180 30 353/8 285/8 21 201/2 x 201/218 x 18
n630 7.1 2380 18611495 28 5648 5443 5254 5082 4921 3564
CUBE-200 30 353/8 285/8 21 201/2 x 201/2 n500 6.2 2812 18221210 25 6806 6451 6108 5748 5350
CUBE-220 34 4225/32 337/8 251/2 261/2 x 261/224 x 24
n450 7.3 3585 2624955 25 7607 7202 6799 6347 5844
CUBE-240 34 4225/32 337/8 251/2 261/2 x 261/2 n410 6.4 3717 2471930 24 8431 7985 7536 6953 6375
CUBE-300 40 50 36 29 321/2 x 321/2 30 x 30 n355 6.9 5777 4227905 32 14727 14266 13788 13223 12614 9178
CUBE-360 46 5611/16 391/8 293/8 381/2 x 381/2 36 x 36 n300 6.9 8092 6023690 30 18611 17884 17115 16236 15243
For complete product information contact your Brucker sales representative.
Upblast Roof Exhaust Belt Drive - CUBEModel CUBE Centrifugal Roof Exhaust fans are belt drive. These fans are specifically designed for roof mounted applications. Exhaust air is discharged directly upward, away from the roof surface. Fan wheels are centrifugal, backward inclined, and constructed of aluminum. Adjustable motor pulleys allow for final system balancing.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 9
GREE
NHEC
K
Upblast Roof Exhaust Belt Drive - CUBEOPTiOnS AnD ACCESSORiES • Galvanized birdscreen• Gravity and motorized dampers for non-UL 762
applications• Galvanized roof curbs• Grease trap w/drain connection• Hinged curb cap kit w/cable
STAnDARD COnSTRUCTiOn FEATURES• Aluminum housing• non-overloading backward inclined aluminum wheel• Curb cap with prepunched mounting holes• Motor and drives isolated on shock mounts• Drain trough• Ball bearing motors• Adjustable motor pulley• Adjustable motor plate• Fan shaft mounted in ball bearings• Static resistant belts• Corrosion resistant fasteners• nema-1 disconnect• Heat baffles• UL/cUL 705 Electrical• UL/cUL 762 Grease• Drain connection
CUBe HiGH PressUre Condensed PerformanCe ranGes & dimensional data - in stoCk
*May be greater depending on motor. All dimensions in inches. Dimension A - given is the inside dimensions of the curb cap.^Dampers should not be used in grease applications.The roof curb should be 11/2 in. less than the curb cap to allow for roofing and flashing. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
MODEL A B C* D ROOF OPENING
DAMPER SIZE^
MIN/MAX RPM
SONES @ .5 in.
PERFORMANCE IN INCHES WG
.5 .75 1.25 1.75 2.25 2.75
CUBE-101HP 19 247/8 233/4 173/8 141/2 x 141/2 12 x 121300 6.0 335
2580 16.8 1014 969 861 735 550
CUBe PerformanCe data - in stoCk Stock Model CUBE fans include disconnect switch, UL/cUL 762 label and heat baffle.
MODEL HP RPM TS SONES @ 0 in.
MAXBHP
PERFORMANCE IN INCHES WG
0 .125 .25 .375 .5 .625 .75 1CUBE-101-4G
1191-1660 RPM 1/4 HP, 115/60/1 ODP
CUBE-101-3G1408-1820 RPM
1/3 HP, 115/208-230/60/1 ODP
1/4
860 2505 4.6 0.04 732 625 481
1205 3509 7.7 0.100 1025 957 873 782 662
1660 4834 12.7 0.26 1413 1364 1313 1251 1189 1125 1056 861
1/3 1820 5300 14.3 0.35 1549 1505 1458 1406 1350 1293 1234 1106
CUBE-121-3G1068-1545 RPM
1/3 HP, 115/230/60/1 ODP
1/3
1045 3573 6.5 0.105 1233 1141 1053 944 798
1410 4821 11.1 0.26 1664 1594 1528 1463 1398 1315 1224 965
1545 5283 12.8 0.34 1824 1760 1698 1639 1580 1518 1441 1262
CUBE-141-LMDG590-1595 RPM
1/4590 2259 5.0 0.040 1068 851
1105 4230 10.9 0.26 2001 1905 1792 1667 1515 1318 998
1/3 1210 4632 12.2 0.34 2191 2106 2006 1896 1772 1628 1442
1/2 1390 5322 14.9 0.52 2517 2445 2361 2271 2173 2068 1949 1642
3/4 1595 6106 20 0.79 2889 2825 2757 2683 2601 2517 2429 2225
CUBE-161-LMDG730-1390 RPM
1/4730 3177 8.1 0.15 2098 1904 1669 1389
875 3808 11.0 0.26 2515 2361 2177 1974 1743 1364
1/3 965 4200 12.4 0.35 2774 2637 2476 2300 2109 1893 1583
1/2 1110 4831 15.0 0.54 3190 3072 2940 2796 2640 2475 2297 1770
3/4 1265 5505 18.5 0.79 3636 3532 3425 3301 3172 3035 2893 2582
1 1390 6049 22 1.05 3995 3900 3806 3698 3584 3464 3340 3078
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com10
MODEL HP RPM TS SONES @ 0 in.
MAXBHP
PERFORMANCE IN INCHES WG
0 .125 .25 .375 .5 .625 .75 1 1.25 1.50
CUBE-180-LMDG630-1495 RPM
1/4630 3051 7.1 0.16 2380 2154 1861 1403
745 3608 9.2 0.26 2814 2616 2448 2143 1763
1/3 820 3971 11.2 0.34 3097 2915 2759 2525 2257 1866
1/2 940 4552 13.8 0.52 3551 3388 3243 3115 2879 2654 2363
3/4 1075 5206 16.5 0.78 4061 3919 3786 3666 3554 3344 3141 2652
1 1185 5739 18.5 1.04 4476 4347 4223 4108 4005 3903 3702 3336
11/2 1360 6586 23 1.58 5137 5025 4913 4811 4710 4620 4531 4232
2 1495 7240 28 2.10 5647 5545 5443 5345 5253 5162 5082 4921
CUBE-200-LMDG500-1210 RPM
1/4500 2797 6.2 0.15 2812 2386 1821
605 3385 8.1 0.26 3402 3054 2674 2144
1/3 665 3721 9.4 0.35 3740 3421 3095 2699 2072
1/2 760 4252 12.1 0.52 4274 3993 3718 3413 3048 2517
3/4 875 4896 16.3 0.79 4921 4676 4438 4192 3922 3626 3240
1 960 5372 18.7 1.04 5399 5175 4957 4742 4508 4253 3985 3168
11/2 1100 6155 23 1.57 6187 5991 5798 5610 5420 5216 5006 4528
2 1210 6771 25 2.09 6805 6628 6450 6279 6108 5932 5747 5349
CUBE-220-LMDG475-930 RPM
1/4 475 3046 7.9 0.23 3783 3377 2896 2268
1/3 520 3335 9.3 0.30 4142 3770 3357 2845
1/2 600 3848 12 0.52 4779 4457 4124 3736 3279
3/4 685 4394 14.8 0.78 5457 5174 4893 4581 4234 3836 3383
1 755 4842 17.3 1.04 6014 5758 5502 5239 4944 4620 4258
11/2 865 5549 20 1.57 6890 6667 6443 6220 5987 5729 5453 4835
2 955 6130 25 2.11 7607 7405 7202 7000 6799 6580 6347 5844
CUBE-240-LMDG 410-930 RPM
1/4410 2629 6.4 0.18 3716 3169 2471
465 2982 7.6 0.26 4215 3767 3187 2162
1/3 510 3271 8.9 0.34 4623 4242 3716 3134
1/2 585 3752 11.5 0.51 5303 4960 4539 4093 3565
3/4 670 4297 14.3 0.79 6073 5762 5460 5052 4059 4202 3524
1 735 4714 16.6 1.04 6663 6370 6133 5764 5409 5037 4618
11/2 845 5419 19.6 1.58 7660 7399 7183 6947 6615 6304 6002 5282
2 930 5965 24 2.10 8431 8194 7985 7798 7536 7233 6953 6375
CUBE-300-LMDG355-905 RPM
1/3355 2834 6.9 0.31 5777 5131 4226
365 2914 7.2 0.34 5939 5316 4463
1/2 420 3353 9.0 0.52 6834 6314 5659 4820
3/4 480 3832 11.0 0.77 7811 7376 6844 6231 5440
1 530 4231 13.3 1.05 8624 8231 7771 7245 6636 5879
11/2 605 4830 17.0 1.56 9845 9500 9127 8705 8226 7707 7083
2 665 5309 20 2.07 10821 10508 10192 9410 8967 8495 7270
3 765 6108 24 3.15 12449 12176 11903 11607 11273 10938 10553 9743
5 905 7226 32 5.19 14727 14496 14266 14036 13788 13505 13203 12614
CUBE-360-LMDG300-690 RPM
1/2300 2395 6.9 0.43 8092 7206 6023
320 2555 7.7 0.51 8631 7820 6755 5256
3/4 365 2914 10.2 0.78 9845 9142 8299 7286 5767
1 400 3193 12.7 1.02 10789 10153 9426 8556 7575
11/2 460 3672 16.8 1.55 12408 11862 11281 10587 9814 8812 7809
2 505 4031 20.0 2.06 13621 13125 12602 12022 11359 10616 9878
3 580 4630 23.0 3.02 15644 15212 14769 14306 13783 13190 12597 11287 9381
5 690 5508 30.0 5.26 18611 18248 17884 17504 17115 16675 16236 15243 14187 12985
CUBe PerformanCe data - in stoCk Stock Model CUBE fans include disconnect switch, UL/cUL 762 label and heat baffle.
Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
Upblast Roof Exhaust Belt Drive - CUBE
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 11
GREE
NHEC
K
Sidewall Exhaust Direct Drive - CWB
CWB standard Condensed PerformanCe ranGes & dimensional data
MODEL A B** C WALL OPENING
DAMPER SIZE^
IN STOCK SIZES (n)
MIN/MAX RPM
SONES @ 0 in.
PERFORMANCE IN INCHES WG0 .25 .5 .75 1 2
CWB-141 287/8 293/4 221/8 151/2 x 151/2 15 x 15 n590 5.0 1069
1725 26 3125 3005 2865 2711 2539
CWB-180 353/8 285/8 273/4 171/2 x 171/2 17 x 17 n630 7.1 2380 1861
1495 28 5648 5443 5254 5082 4921 3564
• Aluminum housing• non-overloading backward inclined aluminum wheel• Birdscreen mounted to the discharge perimeter• Removable mounting plate• Ball bearing motors• Motors and drives isolated on shock mounts• Adjustable motor pulley• Adjustable motor plate• Fan shaft mounted in ball bearing pillow blocks• Static resistant belts• Corrosion resistant fasteners• nema-1 disconnect• UL/cUL 705 Electrical• UL/cUL 762 Grease (Size 098 and up)
• Gravity and motorized dampers for non-UL 762 applications
OPTiOnS AnD ACCESSORiES STAnDARD COnSTRUCTiOn FEATURES
**May be greater depending on motor. All dimensions in inches.Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.^Dampers should not be used in grease applications.
CWB PerformanCe data - in stoCk
MODEL HP RPM TS SONES @ 0 in
MAX BHP
PERFORMANCE IN INCHES WG
0 .125 .25 .375 .5 .75 1 1.25 1.5 1.75
CWB-141-LMDG590-1590 RPM
1/4590 2259 7.3 0.04 1069 851
1090 4173 10.7 0.25 1975 1877 1763 1633 1476
1/3 1200 4594 12.1 0.34 2174 2088 1987 1875 1749 1410
1/2 1400 5360 15.2 0.53 2537 2465 2382 2292 2196 1974 1675
3/4 1590 6087 19.9 0.78 2881 2817 2748 2674 2592 2420 2213 1952
1 1725 6605 26 1.0 3125 3066 3005 2936 2865 2711 2539 2339 2085 1704
CWB-180-LMDG545-1480 RPM
1/4 740 3584 9.1 0.25 2795 2596 2422 2115 1723
1/3 830 4019 11.4 0.36 3135 2954 2799 2575 2315
1/2 960 4649 14.2 0.55 3626 3466 3323 3197 2981 2487
3/4 1070 5182 16.4 0.77 4042 3898 3765 3645 3533 3113 2613
1 1200 5811 18.8 1.08 4533 4405 4281 4168 4066 3778 3411 2948
11/2 1360 6586 22 1.58 5137 5024 4911 4809 4710 4531 4229 3909
2 1480 7168 26 2.03 5591 5487 5383 5284 5193 5021 4845 4517
Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com12
Ceiling Exhaust Fans - SPModel SP Ceiling Exhaust fans are designed for clean air applications where low sound levels are desired. Low sound levels are achieved through quiet running forward curved wheels.
SP-A
SP-B
SP FanSSTanDaRD FEaTURES
a B C
3 3 3Backdraft Damper - Prevents unwanted backdrafts.
3Spring Loaded Aluminum Backdraft Damper - Eliminates rattling or unwanted backdrafts (sizes 110 and up).
3Outlet - Both square and round outlets are field rotatable from horizontal to vertical discharge.
3 3 3Round Outlet (4 or 6 in.) - up to size A90. Versatile for quick, easy connections.
3 3Power Assembly - Removes quickly for maintenance.
3External Electrical Access - Eliminates removing motor pack, saving installation time.
3 3 Electrical Knockout - Eliminates drilling holes.
3 3 3Disconnect (Plug Type) - Servicing is quick and safe.
3 3 Electrical Juntion Box - Large for easy wiring.
3 3Attractive Designer Grille - Concealed attachment screws securely to fasten grille to housing for quiet, rattle free operation.
3 3 3Mounting Brackets - Fully adjustable for multiple installation types.
3 3Housing - Embossed galvanized steel for rigidity and low profile for height restricted areas.
3 3 3PSC Compatible Motors - 50 cycle, 220v, and 240v options. 60 cycle, 115v, 208v, 220v, 230v, and 277v options. (Check factory for availability)
3 3 3 3 Year Warranty
3 3 3UL listed for above showers w/ GFCi branch protected circuit
OPTiOnS AnD ACCESSORiES • Vibration isolation kits• Speed controls• Roof discharge accessories• Wall discharge accessories• Transitions
SP-C
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 13
GREE
NHEC
K
C
D
B A
E
B A
C D
BA
C D
E
E
C
B A
DE
All dimensions in inches.Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft damper. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values are for installation type B: free inlet sone levels. The AMCA Certified Ratings Sound Seal applies to sone ratings only.
sP PerformanCe & dimensional data - in stoCk
UL/cUL 507E33599 Ceiling Exhaust Fans are also UL Listed for sizes 50 through 390 for above bathtub/shower with GFCi branch protected circuit. File no. E33599
MODEL A B COUTLET
RPM AMPS WATTS SONES @ 0 IN. GRILLE SIZE
PERFORMANCE IN INCHES WGD E 0.00 .100 .125 .250 .375 .500 .625 .750 1.00
SP-C50 71/2 71/4 35/8 3 dia. x 15/8 1680 0.80 46 2.9 91/4 x 9 52 49 48 46 43 37 29
SP-B90 137/8 111/2 715/16 6 dia. x 11/4 700 0.65 50 1.9 141/2 x 123/4 102 92 88 75 59 45 30
SP-B110 137/8 111/2 715/16 6 dia. x 11/4 950 1.14 80 2.0 141/2 x 123/4 133 114 110 97 95 94 91 85 50
SP-B150 137/8 111/2 715/16 6 dia. x 11/4 1050 1.70 129 3.0 141/2 x 123/4 160 156 155 154 152 149 147 138 92
SP-B200 137/8 111/2 715/16 6 dia. x 11/4 1100 2.20 173 4.4 141/2 x 123/4 197 195 194 191 187 184 181 166 128
SP-A110 131/4 105/8 101/2 8 6 950 0.58 49 1.3 143/4 x 123/4 119 110 106 88
SP-A125 131/4 105/8 101/2 8 6 1100 0.62 53 1.4 143/4 x 123/4 135 123 121 104
SP-A190 131/4 105/8 101/2 8 6 1400 1.30 113 3.2 143/4 x 123/4 216 197 192 167 133
SP-A250 14 117/8 111/2 8 8 1000 0.77 83 2.9 143/4 x 123/4 272 251 246 227 210 185 157 119
SP-A290 14 117/8 111/2 8 8 1050 0.72 81 3.2 143/4 x 123/4 315 293 287 257 231 207 175 124
SP-A390 14 117/8 111/2 8 8 1350 1.34 135 5.4 143/4 x 123/4 410 395 391 368 345 325 307 279
SP-A410 18 143/8 141/2 8 8 1000 1.74 121 4.1 193/8 x 163/8 443 413 405 351 305
SP-A510 18 143/8 141/2 8 8 1070 3.30 224 6.1 193/8 x 163/8 557 512 501 439 392 325
SP-A700 137/8 111/2 115/8 191/2 8 1100 3.20 350 1.9 251/8 x 131/2 757 729 723 700 679 649 613 560 396
SP-A710 18 143/8 141/2 10 8 1080 4.40 285 7.4 193/8 x 163/8 752 714 701 653 588 485 320
SP-A780 18 143/8 141/2 10 8 1600 3.30 348 10.2 193/8 x 163/8 812 782 775 741 704 665 625 581
SP-A900 233/4 143/8 141/2 183/4 8 950 4.00 285 5.2 25 x 163/8 955 907 896 841 773 701
SP-A1050 233/4 143/8 141/2 183/4 8 1095 6.30 420 7.2 25 x 163/8 1125 1059 1043 964 885 796 662
SP-A1410 233/4 143/8 141/2 183/4 8 1450 7.40 786 11.6 25 x 163/8 1455 1414 1404 1353 1307 1262 1218 1174
SP-A1550 233/4 143/8 141/2 183/4 8 1610 8.60 818 12.4 25 x 163/8 1607 1568 1558 1506 1449 1407 1369 1323
C
D
B A
E
B A
C D
BA
C D
E
E
C
B A
DE C
D
B A
E
B A
C D
BA
C D
E
E
C
B A
DE
C
D
B A
E
B A
C D
BA
C D
E
E
C
B A
DE
SP-C50 SP-A110 through SP-A510 and SP-A710 & SP-A780
SP-B50 through SP-B200 SP-A700, SP-A900 & SP-A1550
Greenheck Fan Corporation certifies that the SP models shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
Ceiling Exhaust Fans - SP
For complete product information contact your Brucker sales representative.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com14
Inline Cabinet Exhaust Fans - CSPModel CSP inline Cabinet fans are designed for clean air applications where low sound levels are desired. Low sound levels are achieved through quiet running forward curved wheels.
C
AB
Ddia.
InletF x G
B A
C
DE
F
G
CSP-B
CSP-ACSP FAnS
STAnDARD FEATURESA B
3 3Aluminum Backdraft Damper- Prevents unwanted backdrafts.
3Spring Loaded Aluminum Backdraft Damper - Eliminates rattling or unwanted backdrafts.
3 3Power Assembly - Removes quickly and is rotatable from horizontal to vertical discharge.
3 3External Electrical Access - Eliminates removing motor pack, saving installation time.
3 3Access Panel - Gain easy access to internal components once installed.
3 3Mounting Brackets - Fully adjustable for multiple installation types.
3 3 Compatible with Speed Controllers
3 3 3 Year Warranty
3 3UL listed for above showers w/ GFCi branch protected circuit.
A
C
B
CSP-A - DOUBLE SCROLL
OPTiOnS AnD ACCESSORiES • Vibration isolation kits• Speed controls• Roof discharge accessories• Wall discharge accessories• Transitions
PERFORMAnCEModels CSP-B110 through A3600 are duct mounted with performance capabilities of 77 cfm to 3,778 cfm and up to 1 in. wg of static pressure.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 15
GREE
NHEC
K
Inline Cabinet Exhaust Fans - CSP
Greenheck Fan Corporation certifies that the CSP models shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
CsP PerformanCe and dimensional data - in stoCk
UL/cUL 507E33599 Cabinet Fans are also UL Listed for above bathtub/shower with GFCi branch protected circuit. File no. E33599
MODEL A B C D E F G RPM AMPS WATTS WT PERFORMANCE IN INCHES WG0 .125 .25 .375 .5 .75 1
CSP-A110 131/4 105/8 101/2 8 6 12 91/4 950 0.62 51 16CFM 124 110 102 77
Sones 1.1 1.1 1.3 1.3
CSP-A125 131/4 105/8 101/2 8 6 12 91/4 1100 0.63 55 16CFM 138 124 113 91
Sones 1.4 1.3 1.4 1.7
CSP-A190 131/4 105/8 101/2 8 6 12 91/4 1400 1.10 100 16CFM 215 198 180 159 121
Sones 2.3 2.2 2.7 2.9 3.0
CSP-A250 14 107/8 111/4 8 8 127/8 10 1000 0.79 83 23CFM 266 241 221 205 187 132
Sones 1.3 1.5 2.3 3.3 3.4 3.0
CSP-A290 14 107/8 111/4 8 8 127/8 10 1050 0.71 80 23CFM 318 292 265 248 229 144
Sones 1.6 1.8 2.6 3.3 4.0 3.4
CSP-A390 14 107/8 111/4 8 8 127/8 10 1350 1.33 144 23CFM 412 397 382 363 339 309
Sones 2.8 2.8 3.2 3.7 4.7 6.5
CSP-A410 18 143/8 141/2 8 8 167/8 131/4 1000 1.87 139 36CFM 447 403 364 316 217
Sones 2.2 2.2 2.5 2.7 2.7
CSP-A510 18 143/8 141/2 8 8 167/8 131/4 1070 3.11 217 36CFM 545 506 464 405 324
Sones 3.1 2.8 2.8 2.7 3.1
CSP-A700 235/8 115/8 101/2 191/2 8 225/8 115/8 1100 3.20 350 34CFM 766 752 739 726 702 635 418
Sones 2.6 2.4 2.4 2.5 2.6 3.0 4.9
CSP-A710 18 143/8 141/2 10 8 167/8 131/4 1080 4.40 325 36CFM 737 688 635 566 474
Sones 3.2 3.2 3.3 2.7 2.5
CSP-A780 18 143/8 141/2 10 8 167/8 131/4 1600 3.77 405 36CFM 813 776 741 707 671 603 527
Sones 3.8 3.6 3.5 3.4 3.5 3.8 4.3
CSP-A900 233/4 143/8 141/2 183/4 8 225/8 131/4 950 4.87 328 39CFM 908 840 782 714 631
Sones 1.9 2.0 2.3 2.6 2.9
CSP-A1050 233/4 143/8 141/2 183/4 8 225/8 131/4 1095 6.65 455 39CFM 1182 1093 1013 922 832
Sones 3.5 3.1 3.1 3.4 3.4
CSP-A1410 233/4 143/8 141/2 183/4 8 225/8 131/4 1450 7.80 822 39CFM 1584 1533 1483 1439 1395 1293 1181
Sones 4.2 4.0 4.1 4.2 4.3 4.6 5.0
CSP-A1550 233/4 143/8 141/2 183/4 8 225/8 131/4 1610 8.32 830 39CFM 1672 1604 1542 1484 1427 1306 1171
Sones 5.8 5.3 5.4 5.4 5.1 5.2 5.8
CSP-A1750 35 143/4 143/4 28 6 323/4 13 1130 6.60 550 68CFM 1842 1749 1619 1463 1283 771
Sones 6.4 6.0 5.5 5.3 4.7 3.8
CSP-A2150 35 143/4 143/4 28 6 323/4 13 1100 7.80 735 68CFM 2249 2156 2044 1900 1701 1114
Sones 6.0 5.8 5.2 5.0 4.6 3.4
All dimensions in inches.Performance certified is for Model CSP inline for installation type D: Ducted inlet, Ducted outlet. Performance ratings include the effects of a backdraft damper. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) from the test inlet duct in a hemispherical free field calculatd per AMCA Standard 301. Values are for installation type D: Ducted inlet fan sone levels. Ratings do not include the effects of duct end correction. Ratings are based on 10 ft. of insulated duct. The AMCA Certified Ratings Seal applies to air performance only.
For complete product information contact your Brucker sales representative.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com16
Roof & Wall Discharge Accessories
All dimensions in inches.
All dimensions in inches.
All dimensions in inches.
B
Dia. DC
A
11/2 in.
MODEL RCC-7• Weathertight aluminum construction • integral birdscreen • Built in curb cap • Requires roof curb
A
B
CD
E
MODEL RJ Pitched Roof Cap• Steel construction with black enamel finish • integral flashing flange • Built in birdscreen and damper
B
CD
Dia.A
13/4 in.
B
CD
Dia.A
111/8
31/2
10
91/4
11 1/2
51/8
MODEL GRS• All aluminum exterior
construction• Galvanized steel internal supports • integral birdscreen • Built in curb cap • Requires roof curb
MODEL EL - 10x3 Elbow Discharge with Grille• Designed for installation under roof eaves • Painted steel louvered grille • Built in damper • For SP/CSP sizes 50-290
CURB CAP
B
Dia. DC
A
MODEL RFC-7• Weathertight aluminum construction • integral birdscreen • Built in flashing flange
FLASHinG FLAnGE
HAnGinG ViBRATiOn iSOLATORSVibration isolator kits are available for suspended installations. Kits include all hardware necessary to mount one unit, with the exception of 10-32 threaded rod to be supplied by others. Fan mounting brackets include prepunched mounting holes for ease of installation.
MODEL FOR USE WiTH SiZES A B C D Dia.
RCC-7 50-390 15 12 10 63/8 7
GRS-10 410-710 19 201/2 61/4 3 101/4
GRS-12 780-1050 22 243/4 77/8 31/4 121/4
GRS-16 1410-2150 26 285/8 83/4 33/4 165/16
GRS-20 3600 30 35 91/4 41/4 205/16
MODEL FOR USEWiTH SiZES A B C D E THROAT
RJ-4 C50, B50-B80 11 91/4 81/4 55/16 41/2 4 in. Dia.
RJ-6 x 9 B90-B200 A50-A390 183/4 141/4 141/2 103/8 61/2 6 x 9
RJ-10 x 10 A410-A1050 181/2 271/2 153/4 235/8 91/2 10 x 10
MODEL FOR USE WITH SIZES A B C D Dia.
RFC-7 50-390 18 12 10 63/8 7
AB
10-32 hangingsupport rod
by others
CD
E
AB
RJ-10X10
RJ-4 & RJ-6 x 9
RJ-10 x 10
Roof Discharge Accessories
Flat Roof Caps
All dimensions in inches.
UniT SiZE A B
B50-B200 41/2 155/8
A50-A190 51/2 145/8
A200-A390 63/4 151/2
A410, A510 A710, A780 91/4 195/8
A700 51/2 251/8
A900-A1050 A1410-A1550 91/4 253/8
A1750, A2150 91/4 363/4
A3600 91/4 485/8
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 17
GREE
NHEC
K
Wall Discharge Accessories
MODEL WL Wall Louvered Discharge• Anodized
aluminum grille• Built in damper• not recommended
for exterior applications exposed to severe weather conditions. An external wall louver is recommended for such applications.
MODEL WC (Round Connection)Hooded Wall Cap• Aluminum construction -
aluminum finish• For outside wall
applications• Built in birdscreen (not
available on WC-4) and damper
MODEL WC (Square/Rectangular Connections)Hooded Wall Cap• Steel construction with
black enamel finish• For outside wall
applications• Built in birdscreen and
damper
MODEL RDC Round Duct Connector• Replaces the standard
square discharge duct- connector and damper.
• Uses existing mounting holes
• Galvanized steel construction
• RDC 6 includes a damper• RDC 8 does not include a
damper
30
20
10
98
7
6
5
4
3
2
1.01 .02 .03 .04 .05 .06 .07 .08 .09.10 .2 .3 .4 .5 .6
Pressure Drop in Inches of Water Gauge
Above accessories tested with 4 feet of inlet duct
WC-10x3WC-6RJ-6x9EL-10x3WL-10x3BVE-808RFC-7RCC-7
BVE-128WC-8x8WC-8
BVE-157WC-18x8
RJ-10x10
WL-18x6
CF
M x
100
ACCESSORY PRESSURE DROPSThe chart below can be used with all of the discharge accessories shown on these two pages. Specific pressure drop values for these accessories must be included in total system calculations for proper fan selection.
*Used in conjunction with RDC-6.All dimensions in inches.
All dimensions in inches.All dimensions in inches.
All dimensions in inches.
All dimensions in inches.
B
ECA
DE
D
A
G
C
B
E
F
EB
C
AD
RDC-8
MODEL FOR USEWITH SIZES A B C D E
WC-4 C50, B50-B80 61/2 6 4 23/4 8.5
WC-6 B90-B200A50-A190 8 8 6 41/8 8.5
WC-8 A200-A510 11 11 8 51/8 8.5
MODEL FOR USEWITH SIZES A B C D E F G
WC-10 x 3 50-290 51/2 123/4 31/2 101/4 111/8 41/4 5
WC-8 x 8 200-510 101/4 101/4 81/4 81/4 81/4 63/4 5
WC-18 x 8 700-1550 101/4 201/4 81/4 181/4 181/4 63/4 5
MODEL FOR USEWITH SIZES A B C D E
WL-10 x 3 50-290 12 51/4 10 73/4 31/2
WL-18 x 6 390-1550 19 3/4 8 18 9 6
MODEL FOR USEWITH SIZES DIA.
RDC-6 A110-A190 6
RDC-8 A200-A510 8
MODEL TR 6x4Transition Duct Reducer• Reduces duct from 6 to 4 inches.• Galvanized steel construction
MODEL FOR USEWITH SIZES
TR 6 x 4
B50-B200
A50-A90
A110-A190*
RDC-6
See Broan Section Page 46 for additional roof and wall accessories.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com18
BsQ standard Condensed PerformanCe ranGes & dimensional data
*May vary with motor size. All dimensions in inches.
MODEL A B C D* DAMPER SIZES
IN STOCKSIZES (n)
MIN/MAXRPM
SONES@ .125 in.
PERFORMANCE IN INCHES WG.125 .25 .5 .75 1.25 2.25
BSQ-90 21 15 117/8 9 12 x 12 n790 6.0 3532691 28 1579 1549 1488 1420 1271 866
BSQ-100 21 17 137/8 9 14 x 14 n790 6.0 5282556 26 2066 2029 1956 1882 1734
BSQ-120 21 19 157/8 9 16 x 16 n790 6.5 758 5902490 31 2779 2736 2650 2563 2386 1984
BSQ-140 22 23 197/8 9 20 x 20 n790 6.1 1341 11602135 30 4009 3958 3856 3741 3494 2861
BSQ-180 28 28 237/8 11 24 x 24 n590 9.9 2153 17771645 29 6656 6565 6376 6178 5744 4450
BSQ-240 34 39 347/8 13 35 x 35 n390 8.6 3271 23421225 41 11972 11801 11460 11070 10245 8149
BSQ-300 38 46 417/8 13 42 x 42 n375 9.6 6176 5271967 33 17693 17396 16776 16124 14888 11047
• Galvanized steel housing• non-overloading backward inclined aluminum wheel• Side access panels• inlet and outlet duct connection flanges• Ball bearing motors• Adjustable motor pulley• Adjustable motor plate• Fan shaft mounted in ball bearing pillow blocks• Static resistant belts• Corrosion resistant fasteners• UL/cUL 705 Electrical
OPTiOnS AnD ACCESSORiES • Motor covers-standard• Gravity and motorized Dampers• isolators
STAnDARD COnSTRUCTiOn FEATURES
A
C sq.
D*
C sq.B sq.
A 1 in.1 in.
C sq.
B sq.
C sq.
B sq.
sQ standard Condensed PerformanCe ranGes & dimensional data
* May vary depending on motor size.
SQ BSQ
All dimensions in inches. Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type B: free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
MODEL A B C DAMPER SIZE
IN STOCKSIZES (n)
MIN/MAXRPM
SONES@ 0 in.
PERFORMANCE IN INCHES WG
0 .125 .25 .5 .75 1 1.25 1.75
SQ-75 13 12 87/8 9 x 9 n1050 3.6 241 1461550 6.1 356 294 229
SQ-90 16 15 117/812 x 12
n1050 4.0 500 369 1881550 7.6 738 654 564 334
SQ-95 16 15 117/8 n1050 4.9 623 475 2741550 9.6 919 829 720 461
SQ-100 21 17 137/8 14 x 14 n860 4.8 725 611 4101725 13.1 1454 1402 1349 1227 1077 830
SQ-120 21 19 157/8 16 x 16 n860 4.5 971 843 7041725 14.7 1948 1883 1818 1692 1562 1416 1239
SQ-140 22 23 197/8 20 x 20 n860 7.1 1637 1487 13161725 20 3283 3211 3139 2985 2825 2645 2424 1624
Inline Fans Direct Drive and Belt Drive - SQ/BSQModels SQ and BSQ are the ideal selection for clean air applications (intake, exhaust, return, or make-up air systems) where space is a prime consideration. Fan wheels are centrifugal, backward inclined, and constructed of aluminum.
Model SQ Centrifugal inline fans are direct drive. Maximum operating temperature is 130º F
Model BSQ Centrifugal inline fans are belt drive. Maximum operating temperature is 180º F.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 19
GREE
NHEC
K
sQ PerformanCe data - in stoCk
Base Vibration isolatorModel BVi
Backdraft Damper Model WD-330
SQ & BSQ OPTiOnS AnD ACCESSORiES
MODEL HP RPM TS SONES @ 0 IN.
MAXBHP
PERFORMANCE IN INCHES WG0 .125 .25 .375 .5 .625 .75 1 1.25
SQ-75-DGEX3-Speed
1/90 1050 2233 3.6 0.011 241 146
1/45 1300 2765 4.1 0.210 298 224 133
1/25 1550 3297 6.1 0.035 356 294 229 137
SQ-90-DGEX3-Speed
1/50 1050 2989 4.0 0.020 500 369 188
1/25 1300 3701 5.4 0.040 619 519 397 245
1/10 1550 4412 7.6 0.068 738 654 564 457 334
SQ-95-DGEX3-Speed
1/30 1050 2989 4.9 0.031 623 475 274
1/15 1300 3701 7.6 0.059 771 659 522 352
1/8 1550 4412 9.6 0.100 919 829 720 603 461 276
SQ-100-BX 1/6 1140 3390 7.4 0.071 961 881 786 657
SQ-120-BX 1/6 1140 3917 7.4 0.140 1287 1190 1095 992 873 693
SQ-140-BX 1/3 1140 4346 10.8 0.30 2107 2061 1942 1818 1666 1447 1121
Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (BHP/kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type B: free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
Inline Fans Direct Drive - SQ
Hanging Vibration isolator - Model HVi(Hanger rods supplied by others)
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com20
Inline Fans Belt Drive - BSQ
BsQ PerformanCe data - in stoCkStock Model BSQ fans include disconnect switch, motor cover UL/cUL 705.
MODEL HP RPMSONES @
0 IN.MAXBHP
PERFORMANCE IN INCHES WG.125 .25 .375 .5 .625 .75 1 1.25 1.5 1.75 2
BSQ-90-4X1168-1690 RPM
1/4 HP, 115/60/1 ODP
BSQ-90-3X1695-1750 RPM
1/3 HP, 115/60/1 ODP
1/41050 8.0 0.061 547 443 2901360 11.7 0.14 753 684 605 509 383
1695 16.0 0.26 966 915 859 798 730 655 439
1/3 1750 16.5 0.29 1000 951 898 841 776 708 528
BSQ-100-4X1073-1610 RPM
1/4 HP, 115/60/1 ODP1/4
1050 7.9 0.073 774 671 4981265 9.8 0.13 966 893 798 6831610 15.0 0.26 1266 1207 1149 1089 1004 917
BSQ-120-4X923-1370 RPM
1/4 HP, 115/60/1 ODP
BSQ-120-LMDX1000-2490 RPM
1/41000 7.7 0.102 1026 914 7831370 11.0 0.26 1475 1396 1315 1230 1136 1026
1/3 1500 12.4 0.34 1629 1557 1484 1410 1331 1243 10101/2 1725 15.2 0.52 1893 1831 1768 1705 1641 1572 1425 12433/4 1974 19.7 0.785 2183 2129 2075 2020 1964 1908 1791 1663 1518 13071 2170 23 1.05 2410 2361 2312 2262 2212 2161 2059 1951 1833 1709
11/2 2490 31 1.57 2779 2737 2694 2651 2607 2563 2475 2387 2294 2198
BSQ-140-LMDX800-2135 RPM
1/4800 6.3 0.11 1362 1185 860
1075 10.7 0.26 1925 1808 1679 1535 13071/3 1180 12.0 0.35 2132 2029 1916 1795 1651 14421/2 1355 14.2 0.52 2474 2390 2295 2195 2092 1977 16313/4 1550 16.2 0.78 2852 2781 2702 2619 2532 2442 2246 1955 14291 1710 18.3 1.05 3161 3096 3030 2955 2880 2800 2638 2453 2181 1758
11/2 1960 24 1.58 3640 3584 3528 3469 3404 3338 3201 3059 2904 27182 2135 30 2.04 3975 3923 3872 3821 3763 3703 3583 3454 3324 3181
BSQ-180-LMDX700-1645 RPM
1/3700 10.0 0.24 2649 2387 2023790 10.6 0.35 3046 2840 2569 2210 1499
1/2 905 12.2 0.52 3546 3366 3167 2928 2621 21753/4 1035 14.5 0.78 4101 3947 3789 3606 3398 3166 24111 1140 16.5 1.04 4545 4408 4265 4122 3944 3755 3283 2510
11/2 1310 20 1.58 5259 5145 5021 4896 4772 4630 4302 3911 33652 1440 23 2.07 5803 5699 5590 5476 5363 5250 4979 4678 4318 38383 1645 29 3.14 6656 6566 6475 6377 6278 6179 5981 5744 5485 5216
BSQ-240-LMDX500-1225 RPM
1/2500 10.7 0.35 4518 4001 3325570 12.3 0.53 5279 4845 4363 3704
3/4 650 14.3 0.78 6121 5757 5360 4933 43751 715 16.1 1.04 6795 6476 6133 5757 5358 4847
11/2 820 19.4 1.56 7874 7616 7317 7016 6688 6349 54942 900 22 2.07 8689 8457 8198 7926 7646 7347 6713 58333 1035 28 3.15 10058 9856 9653 9420 9184 8947 8433 7894 7234 63025 1225 41 5.22 11973 11802 11631 11460 11270 11070 10671 10245 9804 9345
BSQ-300-LMDX
3/4410 10.4 0.60 6897 6141449 12.2 0.78 7693 7033 5930 4827
1 494 14.7 1.04 8598 7982 7216 645011/2 566 17.2 1.57 10022 9469 8916 8363 7492 66222 623 19.3 2.09 11129 10636 10156 9676 9047 8418
3668 21 2.59 11997 11546 11096 10647 10132 9617 8157713 23 3.13 12862 12446 12017 11588 11110 10703 9549 7803
5757 25 3.76 13704 13321 12910 12496 12105 11714 10727 9442801 26 4.46 14543 14185 13974 13402 13040 12678 11839 10778 9439845 27 5.23 15380 15041 14539 14037 14253 13604 12860 11957 10839 9309
71/2906 30 6.44 16538 16221 15884 15548 15209 14870 14237 13841 12576 11497 10099967 33 7.85 17693 17396 17086 16776 16450 16124 15526 14888 14171 13273 12242
Greenheck Fan Corporation certifies that the SQ, BSQ models shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
UL/cUL 705E40001 - SQ/BSQ
For complete product information contact your Brucker sales representative.
Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (BHP/kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type B: free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 21
GREE
NHEC
K
For complete product information contact your Brucker sales representative.
F*D
B*C* D
E
AirflowExhaust
AirflowSupply
A Sq.
Greenheck Fan Corporation certifies that the S models shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
direCt drive s standard & dimensional data - steel ProPeller
*May vary due to motor sizes. All dimensions in inches. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
LEVEL 1 - SIZE 8-12 - D, G, E Motor SpeedsLEVEL 1 - SIZE 12-24
E
F*D
B*C* D
AirflowExhaust
AirflowSupply
A sq.G sq.
UL/cUL 705E40001-S
MODEL A PANEL B* C*
DE MIN/MAX
RPMSONES@ 0 in.
#BLADES
PROP PITCH
1 1 1
S-8 13 7 5 1 83/81050 1.5 4 401550 4.9 4 40
S-10 15 83/4 5 1 103/81050 3.2 4 401550 5.9 4 40
S-12 18 103/4 81/4 1 123/8860 4.0 4 321750 8.7 4 32
S-14 20 111/4 81/2 1 143/8860 5.9 4 401750 14.8 4 36
S-16 22 113/4 87/8 1 163/8860 7.4 4 361750 23 4 30
S-18 24 14 107/8 1 183/8860 8.7 4 341750 23 4 21
S-20 26 171/4 11 1 201/2860 10.8 4 28
1750 35 4 35
Sidewall Propeller Fan - Direct Drive - SESidewall Propeller direct drive fans have varied model configuration arrangements available to handle exhaust and supply requirements. Propellers are available in fabricated aluminum, fabricated steel, or cast aluminum blades depending on the level of construction. Three levels of construction are available. Direct drive fans are often preferred for jobs where maintenance access is difficult.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com22
Sidewall Propeller Fan - Direct Drive - SE
All dimensions in inches. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
direCt drive se1 PerformanCe data - in stoCkStock Model SE1 fans are direct drive exhaust and include aluminum propeller, heavy gauge wire motor support, fan guard, UL/cUL 705 and CSA labels.
MODEL MOTOR SPEED
SONES @ 0 in.
FANRPM
#BLADES
PROPPITCH DAMPER
PERFORMANCE IN INCHES WG
0 .1 .125 .25 .375
SE1-8-DGEX
E 1.5 1050 4 40 10 x 10 311 126 100
G 3.5 1350 4 40 10 x 10 399 256 198
D 4.9 1550 4 40 10 x 10 459 351 307 167
SE1-10-DGEX
E 3.2 1050 4 40 12 x 12 626 361
G 4.9 1350 4 40 12 x 12 804 655 615
D 5.9 1550 4 40 12 x 12 924 800 763
SE1-12-DGEX
E 4.3 1050 4 32 14 x 14 982 745 678 383
G 6.0 1350 4 32 14 x 14 1262 1098 1038 798 541
D 7.5 1550 4 32 14 x 14 1449 1309 1271 1042 861
SE1-14-BX B 7.3 1160 4 40 16 x 16 1604 1406 1350 908 720
SE1-16--436-BX B 9.5 1160 4 36 18x18 2702 2512 2461 2067 1359
SE1-18-BX B 10.2 1160 4 29 20 x 20 3238 2987 2908 2434 1510
SE1-20-BX B 13.8 1160 4 28 22 x 22 4227 4030 3974 3621
STAnDARD COnSTRUCTiOn FEATURES• Heavy gauge, galvanized steel fan panel with pre-punched mounting holes• Resilient motor mounts isolate motor vibrations• Corrosion resistant fasteners• ODP single phase• Thermal overload protection with all motors• Level 1 Riveted Aluminum Blades
Sizes 8-12 (D, G, E motor speeds) - Heavy gauge welded zinc plated wire drive frame Sizes 12-24 (A, B, C motor speeds) - Die formed, galvanized steel drive frame assembly
• UL/cUL 705 Electrical
OPTiOnS AnD ACCESSORiES • Wall housings with inlet guard• Speed controls• Gravity and motorized dampers
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 23
GREE
NHEC
K
Sidewall Propeller Fan - Belt Drive - SBESidewall Propeller belt drive fans have varied model configuration arrangements available to handle exhaust and supply requirements. Propellers are available in fabricated steel, or cast aluminum blades depending on the level of construction. Three levels of construction are available. Also two blade designs are available: The “L" design is for low static pressures and low sound levels. The “H" design is for higher static pressures. Belt drive fans offer the ability to adjust fan speed for system
Belt drive sBe Condensed PerformanCe ranGes & dimensional data–steel ProPeller
All dimensions in inches. Please note: Optimum selections shown in bold.Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
For complete product information contact your Brucker sales representative.
Greenheck Fan Corporation certifies that the SB models shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
E
B
AirflowExhaust
F
AirflowSupply
A sq.
C D D
LEVEL 1
UL/cUL 705E40001-SB
MODEL A PANELB EXHAUST
LEVELF SUPPLY
LEVELC EXHAUST
LEVEL DE EXHAUST
LEVELSTOCK SIZES
(n)LEVEL
MAX RPM
MAX SONES @ 0 IN.
PERFORMANCE IN INCHES WG
0 .125 .25 .5 .75 11 & 2 3 1 & 2 3 1 & 2 3 1 & 2 3
SB-20 26 191/2 - 20 - 173/4 - 1 201/2 - n
1L 1085 17.9 5549 4918 42691H 1221 20 4587 4277 3872 2514 10632L 1241 22 6347 5763 53252H 1391 25 5226 4953 4639 3740 1885 1138
SB-24 32 191/2 19 20 201/2 173/4 167/8 11/4 245/8 245/8 n
1L 863 17.4 7176 6367 53451H 1010 19.9 5281 4818 4193 2108 9032L 987 24 8207 7522 67312H 1148 25 6002 5605 5121 3342 1852 9103L 1127 27 8873 8337 7685 55683H 1485 28 7745 7424 7073 6270 5208 3469
SB-30 38 221/2 211/2 21 20 18 191/8 11/4 305/8 305/8 n
1L 685 18.7 11334 10252 86211H 882 22 10077 9341 85602L 950 32 15719 14985 14151 117602H 1221 36 13951 13414 12889 11734 99793L 1100 41 17423 16709 15991 14240 112533H 1432 49 15173 14820 14467 13585 12445 11175
SB-36 44 211/2 28 23 27 20 211/4 2 365/8 365/8 n
1L 550 17.6 15867 14112 116811H 694 20 15252 13797 121112L 693 27 19992 18743 171052H 870 34 19121 18095 16735 138713L 819 28 22543 21377 20081 165053H 1321 59 23810 23304 22798 21710 20232 18473
STAnDARD COnSTRUCTiOn FEATURES• Die formed, galvanized steel drive frame assembly• Adjustable motor pulley• Ball bearing motors• Fan shaft mounted in ball bearing pillow blocks• Static resistant belts• Corrosion resistant fasteners• Level 1 Galvanized and riveted steel blades• UL/cUL 705 Electrical
OPTiOnS AnD ACCESSORiES • Wall housings with inlet guard• Gravity and motorized dampers
E
B
AirflowExhaust
F
AirflowSupply
A sq.
C D D
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com24
Sidewall Propeller Fan - Belt Drive - SBE
Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP/kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
MODEL NUMBER MOTOR HP
FAnRPM
MAX BHP
F.A. SOnES
PERFORMAnCE in inCHES WG
0 .1 .125 .15 .2 .25 .3 .375 .5 .625 .75 1
SBE-1L20-LMDX705-1085 RPM
1/4705 .17 13.3 3606 2835 2450
861 .30 14.3 4404 3794 3671 3455
1/3889 .33 14.9 4547 3949 3830 3654 3067
947 .40 16.1 4843 4270 4155 4043 3647
1/21021 .50 17.0 5222 4675 4566 4461 4180 3746
1085 .60 17.9 5549 5021 4918 4816 4620 4269 3711
SBE-1L24-LMDX562-863 RPM
1/4562 .17 12.3 4673 3577
688 .30 12.8 5721 4890 4659 4378
1/3711 .33 13.2 5912 5114 4891 4654
759 .41 14.1 6311 5572 5367 5158 4621
1/2811 .50 15.6 6744 6062 5872 5677 5255 4528
863 .60 17.4 7176 6545 6367 6187 5820 5345
SBE-1L30-LMDX390-685 RPM
1/4448 .25 10.9 7413 5790
475 .30 11.6 7860 6394 5880
1/3491 .33 12.1 8125 6742 6249
523 .40 13.0 8654 7427 6970 6503
1/2564 .50 14.3 9333 8261 7862 7436
598 .60 15.5 9895 8898 8583 8185 7366
3/4645 .75 17.2 10673 9766 9508 9190 8446 7562
685 .90 18.7 11335 10496 10253 10009 9332 8622
SBE-1L36-LMDX390-550 RPM
1/3361 .34 11.8 10415 7958 6849
384 .41 11.8 11078 8915 8018 6662
1/2412 .5 12.7 11886 9913 9250 8354
438 .61 13.6 12636 10809 10290 9572
3/4471 .76 14.5 13588 11925 11442 10947 9408
500 .90 15.3 14425 12890 12435 11981 10808 8915
1518 1.01 16.1 14944 13482 13044 12605 11569 10084
550 1.20 17.6 15867 14525 14113 13699 12873 11682 9934
sB PerformanCe data - in stoCk
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 25
GREE
NHEC
K
Sidewall Fan Accesories - SE/SBE
Wall HoUsinG dimensional data
WALL HOUSinG & ACCESSORiESWall housings are the safest and most efficient platform for mounting of sidewall propeller fans and their optional accessories. Wall housings allow for a wide range of mounting arrangements to meet specific applications, and can be mounted flush inside, flush outside, or centered in wall. Standard construction is of galvanized steel.
*Select only one. Shown together for illustration only.
Damper
Wall Housing and OSHA Guard - (Std.)
Damper Guard*
Weatherhood*(45º Exhaust only shown)
B
A W.O.
C E
FD
* B dimension will increase by 6 in. when a heavy duty motorized backdraft damper is specified.For complete dimensional information refer to submittal. All dimensions given in inches.
t non-stock items available on next day quick delivery.
STOCK SIZE WALL HOUSING DAMPER GUARD 45º WEATHERHOOD 90ºWEATHERHOOD
DAMPER SIZEA B* W.O. C D E F WIDTH H J
t 8 131/4 19 141/4 51/2 101/4 131/4 111/4 101/2 163/8 12 10 x 10
t 10 151/4 19 161/4 61/2 121/4 147/8 133/8 121/2 181/2 14 12 x 12
t 12 181/4 23 191/4 51/4 141/4 163/8 155/8 141/2 203/8 163/8 14 x 14
t 14 201/4 26 211/4 61/4 161/4 171/2 175/8 161/2 221/2 183/8 16 x 16
t 16 221/4 27 231/4 63/4 181/4 193/8 195/8 181/2 25 203/8 18 x 18
t 18 241/4 28 251/4 6 201/4 22 215/8 201/2 271/2 223/8 20 x 20
** 20 261/4 32 271/4 61/2 221/4 243/4 235/8 221/2 293/4 243/8 22 x 22
** 24 321/4 37 333/4 61/4 261/4 267/8 303/8 291/8 36 313/4 26 x 26
** 30 381/4 38 393/4 61/2 321/4 291/8 361/2 351/8 401/8 377/8 32 x 32
** 36 441/4 39 453/4 63/4 381/4 33 421/2 411/8 451/2 437/8 38 x 38
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com26
Gravity Ventilators - GRSModel GRS is an aluminum ventilator designed for intake (Model GRSi) or relief (Model GRSR) applications with either natural gravity or positive pressure systems. The GRS appearance blends with other Greenheck products and with its low silhouette, avoids the problem of detracting from architectural aesthetics. Exceptional design and construction features make this unit a rugged, efficient, and economical air inlet or outlet.
B
CD
Dia.A
1 in.
B
C
D
Dia.A
3/4 1 in.3/4
All dimensions in inches.Dimension A - given is the inside dimensions of the curb cap.The roof curb should be 11/2 in. less than the curb cap to allow for roofing and flashing.
Grs dimensional data n in stock sizes include birdscreen
Sizes 8-24 Sizes 30-48
For complete product information contact your Brucker sales representative.
MODEL A B C D DIA.THROAT
AREA(FT2)
STOCKSIZES
(n)
CAPACITIES (CFM)
.04 .06 .08 .1 .125 .187 .25 .3 .35
GRS-8 19 201/2 71/4 11/2 81/4 0.37 nRELiEF 203 250 291 325 365 462 559 636 713inTAKE 182 224 257 286 315 394 448 493 530
GRS-10 19 201/2 73/4 2 101/4 0.57 nRELiEF 310 387 450 505 570 695 814 908 1003inTAKE 283 348 399 445 490 611 697 765 823
GRS-12 22 29 10 31/2 121/4 0.82 nRELiEF 440 557 643 724 818 1000 1165 1290 1395inTAKE 406 500 572 637 702 876 999 1097 1180
GRS-15 22 29 10 31/2 141/4 1.12 nRELiEF 630 762 890 1004 1125 1375 1625 1819 2014inTAKE 560 690 790 880 970 1210 1380 1515 1630
GRS-16 26 29 11 41/4 161/4 1.45 nRELiEF 820 1025 1190 1340 1515 1845 2160 2385 2610inTAKE 751 925 1059 1180 1301 1623 1850 2031 2186
GRS-18 30 351/2 93/4 13/4 201/4 1.83 nRELiEF 995 1240 1440 1630 1835 2245 2615 2910 3189inTAKE 913 1124 1286 1434 1580 1972 2248 2468 2656
GRS-20 30 351/2 111/4 33/4 201/4 2.25 nRELiEF 1220 1520 1785 1995 2235 2730 3166 3513 3859inTAKE 1111 1368 1565 1745 1923 2399 2735 3003 3232
GRS-24 34 381/4 11 4 241/2 3.24 nRELiEF 1780 2215 2580 2920 3255 3990 4650 5140 5650inTAKE 1440 1820 2120 2418 2722 3330 3836 4235 4580
GRS-30 40 48 183/4 57/16 301/2 5.032 nRELiEF 2460 2890 3260 3615 4015 4920 5665 6222 6778inTAKE 1770 2360 2580 3270 3680 4470 5130 5524 5820
GRS-36 46 563/4 211/4 6 361/2 7.291 nRELiEF 2990 3820 4515 5075 5670 6990 8140 9005 9820inTAKE 2567 3420 4127 4739 5330 6475 7430 8006 8436
STAnDARD COnSTRUCTiOn FEATURES• Aluminum housing• Aluminum curb cap with prepunched
mounting holes• Recommended roof opening dimension is
at least 2.5 in. larger than the damper size
OPTiOnS AnD ACCESSORiES• Gravity and motorized dampers • Galvanized roof curbs
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 27
GREE
NHEC
K
Centrifugal Utility Fans - SFB
sfB PerformanCe data - in stoCk
OPTiOnS AnD ACCESSORiES
• Vibration isolators• Weatherhood• Belt guard
DISCHARGE POSITIONS(Viewed from Drive Side)
SFB STAnDARD COnSTRUCTiOn FEATURES
HOUSING:• Heavy gauge steel housing with Lock-seam construction• Unit support angles with prepunched mounting holes• Adjustable motor plate• Corrosion resistant fasteners• Entire unit is phosphatized and coated.
BEARINGS, SHAFT, AND WHEEL:• Heavy duty lubricatable, self-aligning ball bearing pillow blocks• Polished, solid steel shafts• Forward curved fan wheel
MODEL A B C D E F G H MIN/MAXCFM
PERFORMANCE IN INCHES WG.125 .5 .875 1.5 2 2.5
SFB-10 22 265/8 193/8 167/8 12 81/2 11 151/8 700 450 7182300 1080 1211 1335 1518 1644
AE
F
G
C
D
B
H
AE
F
G
C
D
B
H
CWTH
CWTAD
CWDB
CWBAD
CCWTH
CCWTAD
CCWDB
CCWBAD
CWBH
CWBAU
CWUB
CWTAU
CCWBH
CCWBAU
CCWUB
CCWTAU
CWTH
CWTAD
CWDB
CWBAD
CCWTH
CCWTAD
CCWDB
CCWBAD
CWBH
CWBAU
CWUB
CWTAU
CCWBH
CCWBAU
CCWUB
CCWTAU
sfB standard Condensed PerformanCe & dimensional data
CFM OV(ft/min.)
PERFORMANCE IN INCHES WG
.025 0.5 0.75 1.0 1.25 1.5 1.75 2.0 2.25 2.5
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
600 851 526 0.05700 993 551 0.07 718 0.11800 1135 578 0.08 732 0.13900 1277 607 .011 757 0.16 885 0.21
1000 1419 639 0.13 782 0.19 902 0.24 1017 0.301100 1561 670 0.16 809 0.23 926 0.29 1030 0.35 1135 0.411200 1703 703 0.20 836 0.26 952 0.34 1052 0.40 1148 0.47 1242 0.541300 1845 738 0.24 868 0.31 978 0.39 1077 0.46 1166 0.53 1256 0.60 1343 0.691400 1986 774 0.29 899 0.37 1005 0.44 1102 0.53 1191 0.60 1272 0.67 1356 0.76 1437 0.851500 2128 810 0.34 931 0.43 1034 0.51 1129 0.60 1216 0.68 1296 0.76 1370 0.84 1450 0.93 1526 1.021600 2270 846 0.41 962 0.49 1065 0.58 1155 0.67 1241 .077 1321 0.86 1395 0.94 1464 1.02 1539 1.12 1611 1.221700 2412 883 0.47 995 0.57 1097 0.66 1183 0.75 1268 0.86 1346 0.96 1420 1.05 1489 1.14 1554 1.22 1624 1.32
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com28
sWB standard Condensed PerformanCe & dimensional data
All dimensions in inches.Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories).
C
D
B
E F
H
A O.D.C
D
B
E F
H
A O.D.
MODEL A B C D E F H STOCK SIZES (n)
MIN/MID MAX/CFM OV PERFORMANCE IN INCHES WG
.5 1 2 3 4 5
SWB-210 22 265/8 183/4 167/8 151/2 81/4 11 n500 791 1078 1475
1250 1977 1770 1968 2317 2657 3003 33262375 3757 3096 3201
SWB-212 23 283/8 213/8 167/8 151/2 95/8 13 n600 729 1020 1372
1650 2007 1775 1943 2262 2569 2868 31472850 3467 2867 2968 3169
SWB-216 303/8 381/8 28 227/8 191/2 131/8 171/2 n1200 789 7623300 2171 1359 1472 1696 1919 2143 23485700 3750 2208 2279
Centrifugal Utility Fans - SWB
SWB STAnDARD COnSTRUCTiOn FEATURES
HOUSING:• Heavy gauge steel housing with Lock-seam construction• Unit support angles with prepunched mounting holes• Adjustable motor plate• Corrosion resistant fasteners• Entire unit is phosphatized and coated.
BEARINGS, SHAFT, AND WHEEL:• Heavy duty lubricatable, self-aligning ball bearing pillow blocks• Polished, solid steel shafts• Backward inlclined steel wheel
OPTiOnS AnD ACCESSORiES
• Vibration isolators• Weatherhood• Belt guard
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 29
GREE
NHEC
K
Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories).
sWB PerformanCe data - in stoCk
MODEL RPM HP MAXBHP
PERFORMANCE IN INCHES WG.25 .5 .75 1 1.5 2 2.5 3 4
SWB-210-LMDX
1670 1/4 .25 1246 1158 1046 9221833 1/3 .33 1383 1307 1214 1108 7372103 1/2 .50 1608 1542 1471 1388 1198 7882408 3/4 .75 1860 1801 1744 1680 1528 1359 11112650 1 1.0 2059 2004 1952 1900 1775 1629 1469 12373033 11/2 1.5 2372 2322 2277 2231 2135 2023 1894 1764 13853339 2 2 2621 2576 2533 2491 2408 2315 2209 2092 1842
SWB-212-LMDX
1500 1/4 .251 1443 1323 1185 9901651 1/3 .334 1606 1504 1388 12521770 1/2 .414 1734 1645 1538 1421 10481891 1/2 .501 1867 1786 1685 1583 13132029 3/4 .612 2017 1940 1851 1757 1544 11702169 3/4 .751 2169 2092 2016 1928 1742 14902265 1 .863 2273 2196 2128 2044 1871 1655 12982376 1 1.001 2392 2315 2257 2176 2016 1833 15742486 11/2 1.150 2509 2434 2377 2306 2153 1986 1772 14352600 11/2 1.316 2629 2559 2501 2440 2293 2140 1962 17182716 11/2 1.501 2751 2686 2627 2574 2434 2293 2132 19292857 2 1.740 2899 2840 2779 2730 2603 2470 2326 2164 16202998 2 2.001 3047 2992 2930 2884 2770 2643 2513 2367 1975
SWB-216-LMDX
982 1/3 .334 2396 2140 17731124 1/2 .501 2805 2599 2352 19961287 3/4 .752 3267 3092 2897 26761347 1 .861 3435 3267 3089 2887 22841416 1 1.001 3628 3468 3307 3117 26341526 11/2 1.252 3933 3786 3639 3473 3092 21531621 11/2 1.503 4195 4057 3917 3774 3438 29761705 2 1.748 4426 4295 4163 4034 3721 33471784 2 2.003 4643 4519 4392 4267 3980 3652 31911905 3 2.439 4974 4858 4740 4621 4368 4083 3737 32312042 3 3.004 5348 5240 5031 5019 4800 4537 4257 39042200 5 3.756 5778 5678 5576 5474 5270 5045 4800 4529 3732
stock Model sWB fans come with cW-tH rotation and discharge and include: steel wheel, weatherhood and UL/cUL 705.
Centrifugal Utility Fans - SWB
For complete product information contact your Brucker sales representative.
UL/cUL 705UL/cUL 762E40001-SWB
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com30
3 3/4" Max.
Thermal Blanket
Lay-In Diffuser
Ceiling Radiation Damper
Tee Bar
EXAMPLE OF THERMAL BLAnKET APPLiCATiOn
ROUnD CRD-2
SERviCE ChaRT STOCK SiZESRound Frame (CRD-2) 6, 8, 10, 12, 16
STAnDARD COnSTRUCTiOn FEATURES• Galvanized steel• UL/cUL 555C Listed• Fabricated to your size
requirements• Rectangular, round or curtain
type
STAnDARD COnSTRUCTiOn FEATURES• G - UL 555 Classified (1 1/2
hour fire resistance rating)• For use in walls, floor, and
partions w/fire resistance ratings less than 3 hours
• Type A curtain (blades in air stream)
• Vertical or horizontal• Spring loaded• 165 degree fusible link
STAnDARD COnSTRUCTiOn FEATURES• UL 555 Classified (1 1/2
hour fire resistance rating)• For use in walls, floor, and
partions w/fire resistance ratings less than 3 hours
• True round (blades in air stream)
• Vertical or horizontal• 13.625" length • 165 degree fusible link
OPTiOnS AnD ACCESSORiES• Thermal blankets (1 in. mineral wool or
quilted ceramic) - 24 in. x 24 in.
Ceiling Radiation DampersGreenheck’s ceiling radiation dampers are qualified under UL/cUL 555C, Standard for Ceiling Dampers. Ceiling radiation dampers are designed to function as a heat barrier in duct outlets penetrating fire resistive membrane ceilings. These dampers may be used in lieu of hinged door type dampers, in ceiling designs listed in the UL/cUL Fire Resistance Directory which allow penetrations.
dfd-150
Dynamic Fire Dampers - DFD-150/DFDR-510
WIDTH (INCHES)
HEIGHT (INCHES) 6 8 10 12 14 16 18 20 24
4 X X X X6 X X X X X X X X X8 X X X X X X X X10 X X X X X X X12 X X X X X X14 X X X X X16 X X X X18 X X X20 X X24 X
SIZES (INCHES)
468
10121416182024
dfdr-510 (roUnd)
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 31
GREE
NHEC
K
Backdraft Dampers, Curbs and Equipment Supports
MODEL FLANGE V H E I MOTORPACKWD-100 NONE X X XWD-200 NONE X X X XWD-320 YES X X XWD-323 YES X XWD-330 NONE X X XWD-410 NONE X X
Greenheck’s backdraft dampers are used in systems to allow airflowin one direction and prevent airflow in the opposite direction.Material=Galvanized
V=Verticle H=Horizontal E=Exhaust I=Intake
MOTORPACKS24 Volt115 Volt230 Volt460 Volt
SIZE/MODEL WD-100 WD-200 WD-320 WD-323 WD-330 WD-410
8X8 X X X
9X9 X
10X10 X X X X X
12X12 X X X X X X
14X14 X X X X X X
16X16 X X X X
18X18 X X X X X X
20X20 X X X X X X
22X22 X X X
24X24 X X X X
26X26 X X X
28X28 X
30X30 X X
32X32 X
36X36 X X
38X38 X
Roof Curbs
Equipment Supports
Roof curbs construction feature is Galv Steel, rigidfiberglass insulation to minimize condensation andreduce sound. Suited for surface mounting on insulatedroof decks. It is welded with a 2" mounting flange.
Model: RH-3
Backdraft Dampers, Curbsand Equipment Supports
Equipment supports are designed for use on both insulatedand non-insulated flat roof decks. They are constructed ofgalvanized steel.
4'Longx12"High6'Longx12"High
dimensional dataSIZES
(INCHES) MAT'L O.D. HEIGHT HEIGHT
15 STL 13.5 12 1817 STL 15.5 12 1819 STL 17.5 12 1822 STL 20.5 12 1824 STL 22.5 12 1826 STL 24.5 12 1830 STL 28.5 12 1834 STL 32.5 12 1840 STL 38.5 12 1846 STL 44.5 12 18
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com32
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 33
ABB
ABB
Variable Frequency Drives 34
Model UH Base Drive 35
Model VCR Vertical Bypass with Circuit Breaker 36
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com34
Variable Frequency Drives
desCriPtion
The ACH550 series is a microprocessor based Pulse Width Modulated (PWM) adjustable speed AC drive The ACH550 drive takes advantage of sophisticated microprocessor control and advanced IGBT powerswitching technology to deliver high-performance con-trol of AC motors for a wide range of HVAC applications
With drives ranging from 1 to 550 HP, the ACH550 series features a universal full graphic interface that “speaks" to the operator in plain English phrases, great-ly simplifying set-up, operation, and fault diagnosis The ACH550 is also programmable in fourteen other languages
Each ACH550 drive comes equipped with an extensive library of pre-programmed HVAC application macros which, at a touch of a button, allow rapid configuration of inputs, outputs, and performance parameters for spe-cific HVAC applications to maximize convenience and minimize start-up time The ACH550 series can handle the most demanding commercial applications in an ef-ficient, dependable, and economic manner
featUresmodels UH & vCr• ABB Microprocessor base Pulse Width Modulated
(PWM) Adjustable frequency AC drives• Modbus, Johnson, Siemens, and BACnet Standard• Integral 5% input line impedance• Built-in first environmental EMI/RFI filter• Built in Real Time Clock• Fault Logger• Built in Assistants for Start-up, Maintenance, and Diag-
nostics• Extremely User Friendly Keypad• Hand, Off, Auto and speed pot all on Keypad• UL/Nema 1 Enclosure
additional featUres model vCr• Vertical Bypass on 480V, 1-50 HP• Fast Acting Semi Conductor fuses in front of VFD• Drive & Bypass contactors• Circuit breaker disconnect• Service switch• No Contactor Chatter• Serial Communications capability even in Bypass• Single Phase protection for motor even in Bypass• Electronic motor overload relay with external reset• 2 wire start/stop dry contact closure• Damper control circuit
Model VcrBase drive w/VerticalBypass and circuit Breaker
Model uhBase drive
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 35
ABB
Model UH- Base Drive
Model uh - Base driveseleCtion CHart - stoCk sizes
Outside dimensions - r1...r4Outside dimensions depend on frame size and enclosure type, as defined below.
Motor data drive data
hP FlA Voltage Model type hP Output Amps Voltage
1-1 5 3 460 VAC ACH550-UH-03A3-4 R1 1-1 5 3 3 480 VAC
2 3 4 460 VAC ACH550-UH-04A1-4 R1 2 4 1 480 VAC
3 4 8 460 VAC ACH550-UH-06A9-4 R1 3 6 9 480 VAC
5 7 6 460 VAC ACH550-UH-08A8-4 R1 5 8 8 480 VAC
7 5 11 460 VAC ACH550-UH-012A-4 R1 7 5 11 9 480 VAC
10 14 460 VAC ACH550-UH-015A-4 R2 10 15 4 480 VAC
15 21 460 VAC ACH550-UH-023A-4 R2 15 23 480 VAC
20 27 460 VAC ACH550-UH-031A-4 R3 20 31 480 VAC
25 34 460 VAC ACH550-UH-038A-4 R3 25 38 480 VAC
30 40 460 VAC ACH550-UH-045A-4 R3 30 44 480 VAC
40 52 460 VAC ACH550-UH-059A-4 R4 40 59 480 VAC
50 65 460 VAC ACH550-UH0-72A-4 R4 50 72 480 VAC
Notes: 1 AC Motor Data is per National Electical Code Table 430 250 for typical motors used in most applications and is provided as typical data only DC motor data is per typcial industry standards Actual motor data may vary
Ul tyPe 1 - oUtside dimensionsref. r1 r2 r3 r4
mm in mm in mm in mm in
W 125 4 9 125 4 9 203 8 0 203 8 0
h 330 13 0 430 16 9 490 19 2 596 23 4
h3 369 14 5 469 18 5 583 23 0 689 27 1
d 212 8 3 222 8 7 231 9 1 262 10 3
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com36
Model VCR - Vertical Bypass with Circuit Breaker
vertiCal e-ByPass, Ul tyPe 1 - oUtside dimensions
Vertical e-Bypass, ul type, r1...r4
seleCtion CHart - stoCk sizes
hP FlA Voltage Model type hP Output Amps
Voltage
1-1 5 3 460 VAC ACH550-VCR-03A3-4+F267 R1 1-1 5 3 3 480 VAC
2 3 4 460 VAC ACH550-VCR-04A1-4+F267 R1 2 4 1 480 VAC
3 4 8 460 VAC ACH550-VCR-06A9-4+F267 R1 3 6 9 480 VAC
5 7 6 460 VAC ACH550-VCR-08A8-4+F267 R1 5 8 8 480 VAC
7 5 11 460 VAC ACH550-VCR-012A-4+F267 R1 7 5 11 9 480 VAC
10 14 460 VAC ACH550-VCR-015A-4+F267 R2 10 15 4 480 VAC
15 21 460 VAC ACH550-VCR-023A-4+F267 R2 15 23 480 VAC
20 27 460 VAC ACH550-VCR-031A-4+F267 R3 20 31 480 VAC
25 34 460 VAC ACH550-VCR-038A-4+F267 R3 25 38 480 VAC
30 40 460 VAC ACH550-VCR-045A-4+F267 R3 30 44 480 VAC
40 52 460 VAC ACH550-VCR-059A-4+F267 R4 40 59 480 VAC
50 65 460 VAC ACH550-VCR-072A-4+F267 R4 50 72 480 VAC
dimen-sions ref.
r1 r2 r3 r4
mm mm in mm in mm in mm in
W 136 5 4 136 5 4 220 8 7 220 8 7
h 1095 43 1 1195 47 1361 53 6 1466 57 7
d 225 10 0 269 10 6 300 11 8 300 11 8
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 37
BROA
N
BROAN
Bath Fans 38
Ventilation Fans - Ultra Silent™ 39
Combination Units 40
Wall Heaters 41
LoSone Ventilators 42
Broan Controls 43
Roof and Wall Caps 44
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com38
Bath Fans
Premium Fans
• Centrifugal blower wheel and 4-pole motor deliver high exhaust capacity at low sound levels.
• All-new, designer styled white polymeric grille complements virtually any decor.
• Torsion spring grille mounting – no tools necessary.
• Metal grille kits (available separately)
Vertical Discharge
Model 673 Ceiling Fan 60 CFM 4.0 Sones.
• Durable polymeric fan blade.
• Spin-on, white polymeric grille.
• Galvanized steel housing.
• Double strength steel mounting brackets with keyhole slots for fast installation.
Deluxe Fans
• Durable Broan-designed blower wheel.
• Torsion spring grille mounting – no tools necessary.
• Compact housing fits easily between ceiling joists or wall studs.
• Double strength steel mounting flanges with keyhole slots for fast installation.
• Metal grille kits (available separately)
Economy Fans
• Torsion spring grille mounting – no tools necessary.
• Compact housing fits easily between ceiling joists or wall studs.
• Covered by U.S. and foreign patents.
• Metal grille kits (available separately)
Model 676 Ceiling Fan110 CFM 4.0 Sones.
Model 684 Ceiling Fan80 CFM 2.5 Sones.
Model 671 Ceiling/Wall Fan70 CFM 3.0 Sones.
Model 670 Ceiling/Wall FanIndustry Exclusive50 CFM 1.5 Sones.
Model 689 Ceiling/Wall Fan60 CFM 3.5 Sones.
Model 688 Ceiling/Wall Fan50 CFM 2.0 Sones.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 39
BROA
N
Ventilation Fans – Ultra Silent™
Qtr fan featUresNearly silent operation 1 0 to 1 5 sones• 100 CFM to 150 CFM• HVI Certified• Motor engineered for continuous operation• UL Listed for use over bathtubs or showers
when connected to a GFCI protected branch circuit• Fits 2" x 8" ceiling construction
Energy star fans use 65% less energy, on average, than standard models and may qualify for local utility rebates.
Fan Model cFM sones Bath sq. Ft. ducting
Qtr080 80 1 0 75 4"
Qtr110 110 1 5 100 4"
MODELS IN STOCK
Motordor ®
Model 12C Motordor® 10” Wall FanIndustry Exclusive
•380 CFM 5.5 Sones.
•Housing features foam-insulateddoor for energy efficiency.
•Separate motor opens door whenfan is turned on, closes door whenunit is turned off.
•Housing adjusts to fit walls from41⁄2” to 91⁄2” thick.
Wall/Ceiling Mount
Model 502 10” Side Discharge Fan
•270 CFM 7.0 Sones.
•Installs easily between ceiling joistsor wall studs.
•Built-in damper prevents backdrafts.
•Fits 31⁄4” x 10” duct.
Vertical Discharge
Model 504 10” Vertical DischargeFan
•350 CFM 6.5 Sones.
•Installs easily between ceilingjoists.
•Fits 10” round duct – use Model472 transition/damper (availableseparately) for 8” round duct
Model 503 8” Side Discharge Fan
•160 CFM 5.0 Sones.
•All other features same as Model502.
Model 505 8” Vertical Discharge Fan
•180 CFM 5.0 Sones.
•Installs easily between ceiling joists.
•Housing features built-in backdraftdamper.
•81⁄4” diameter housing.
•Fits 8” round duct.
•All other features same as Model 504.
Room To Room
•Easy interior wall installation.
•Permanently lubricated motor.
•High-strength, reinforced polymeric fan blade.
•Two attractive white polymeric grillescan be painted to match decor.
Model 511 8” Room To Room Fan
•180 CFM 3.5 Sones.
•Built-in variable speed control.
•Housing adjusts to fit walls from 3”to 51⁄2” thick.
Utility Ventilators
Utility Ventilators
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com40
BROA
N
(847) 437-9690 (309) 691-5160 (219) 546-5556Elk Grove Village Peoria South Bend
Model 696 Fan/Light
•100 CFM 4.0 Sones.
•Does not include heater.
•Designer styled white polymeric grille complements virtuallyany decor.
•Bright 100-watt light capacity (bulb not included).
•Housing lined with 1⁄2” acoustic insulation.
•15 amp circuit acceptable.
•Type IC.
Model 657 Fan/Light
• 70 CFM 3.5 Sones.
• Does not include heater.
• Type IC.
• UL listed for use over bathtubs and showers whenconnected to GFCI-protected branch circuit.
Heater/Fan/Light Combination Units
•Two blower wheels, eachpowered by its own permanently lubricated plug-in motor, quietly deliver high-efficiency performance.
•1300-watt heater for fast, even heat distribution.
•Built-in damper preventsbackdrafts and eliminates metallicclatter.
•Adjustable, slotted mountingbrackets span up to 24” for easyinstallation.
•Polymeric 4” round duct featuresa 2” long tapered sleeve for easy, positive ducting.
Model 655 Heater/Fan/Light
•70 CFM 3.5 Sones.
•Designer styled white polymericgrille complements virtually anydecor.
•Fan and heater functionindependently or together.
•Bright 100-watt light capacity (bulb not included).
•20-amp circuit required.
•Type IC.
•Use with Model 66, three-function control (availableseparately)
Models 655657696
Combination UnitsCombination Units
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 41
BROA
N
Fan/Light Combination Units.
Quality Broan features and easy installationmake this an extremely popular series.
•All-new, designer styled white polymeric grillecomplements virtually any decor.
•Plug-in, permanently lubricated motor.
•Efficient polymeric fan impeller.
•Mounting ears offer quick, sturdy installation.
•UL listed for use over bathtubs and showers when connected to a GFCI-protected branch circuit.
•Polymeric duct connectors with taperedsleeves for easier, positive ducting.
Model 161 One-Bulb Heater/Fan
•70 CFM 3.5 Sones.
•Overall housing dimensions 6” x 121⁄4” x 81⁄8”.
•UL listed for 75°wiring (retrofits).
•Not Type IC.
Heater/Fan units also include Broan quality ventilating features.
•Quiet, highly efficient polymeric blower wheels.
•Polymeric dampers eliminate metallic clatterwhile preventing backdrafts.
•Polymeric 4” round duct connectors with tapered sleeves provide easier, positiveducting.
•Bulb heaters and ventilating fans may beoperated independently or together.
•Heater/Fans available in single packs andProject Paks.
Model 679 Fan/Light
• 70 CFM 3.5 Sones.
• Bright 100-watt lighting capacity (bulb notincluded).
• Shatter-resistant light diffusing lens.
• Type IC.
Combination UnitsCombination Units / Wall Heaters
Fan-Forced Wall heatersConvenient Rugged Reliable Our sturdy 24-gauge steel housing mounts eas-ily between studs in any standard wall, or can be surface mounted where needed A housing mask prevents construction damage to roughed-in units, and protects the housing and its ele-ment And a snap-out wiring cover allows wiring away from tight corners
Model 174• Factory wired for 1500W at 120 V AC–easily
converts to 750W at 120V AC or 1500W at 240V AC
MODEL WATTS VOLTS AMPS
174
750W-1500W 120 6.25/12.5
1125W 208 5.41
1500W 240 6.25
surface Mount kit - Model 84• Includes all hardware for surface mounting of
Broan Comfort-Flo heaters• White enameled, steel enclosure matches
grille color• Measure 12-3/8"W x 9-5/8"H x 3-7/8"D
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com42
12 1/4”(311.2 mm)21 1/2”
(546.1 mm)
11 3/4”(298.4 mm)
4 1/2” X 18 1/2”(114.3 mm X 469.9 mm)
DUCT CONNECTOR
LoSone Ventilators
ceiling Mount Ventilators – 100, 150, 200, 150 & 300 cFMSinglee, impact resistant centrifufal blower wheel driven by a low RPM motor 121/4" x 121/2" x 113/4" high housing Low profile white polymeric grille (14" x 14") or sturdy, low profile metal grille finished with painted white enamel (14" x 14") Built-in backdraft damper Discharges horizontally or vertically through 6" or 8" round duct
ceiling Mount Ventilators – 400, 500 & 700 cFMTwo, impact resistant centrifugal blower wheels driven by low RPM motor 211/2" x 211/4" x 113/4" high housing Sturdy, low profile metal grille finished with painted white enamel (21" x 14") Discharges horizontally or verticallythrough 41/2" x 181/2" duct connector
ceiling Mount Ventilators – 900Single, impact resistant centrifugal blower wheel driven by low RPM motor 22" x 18" x 18" high housing Sturdy,low profile metal grille finished with painted white enamel (21" x 14") Discharges horizontally or verticallythrough 8" x 12" duct connector
Model no. description*
l100* 109 CFM Horizontal, 0 9 Sones; 112 CFM Vertical, 1 0 Sones Polymericgrille 6" rd duct connector 120V
l150* 157 CFM Horizontal, 1 5 Sones; 160 CFM Vertical, 1 6 Sones Polymericgrille 6" rd duct connector 120V
l200* 210 CFM Horizontal, 1 7 Sones; 207 CFM Vertical, 2 0 Sones Polymericgrille 8" rd duct connector 120C
l250* 259 CFM Horizontal, 2 2 Sones; 259 CFM Vertical, 2 6 Sones Polymericgrille 8" rd duct connector 120V
l300* 301 CFM Horizontal, 2 7 Sones; 300 CFM Vertical, 2 6 Sones Polymericgrille 8" rd duct connector 120V
l300kMG* 277 CFM Horizontal, 3 1 Sones; 277 CFM Vertical, 3 7 Sones Metal grille 8" rd duct connector Suitable for kitchen installation 120V
*CFM/Sone ratings at 0 125" static pressure
Model no. description*
l400* 434 CFM Horizontal, 2 3 Sones; 416 CFM Vertical, 2 6 Sones 120V
l500* 514 CFM Horizontal, 3 3 Sones; 512 CFM Vertical, 3 2 Sones 120V
l700* 701 CFM Horizontal, 4 7 Sones; 687 CFM Vertical
Model no. description
MG1 Metal grille kit for 100, 150, 200, 250 & 300 CFM ceiling mount models
961l In-line adapter kit 6" rd For 100 & 150 CFM ceiling mount models
981l In-line adapter kit 6" rd For 200, 250 & 300 CFM ceiling mount models
Model no. description*
l900* 901 CFM Horizontal, 4 1 Sones; 885 CFM Vertical, 3 4 Sones, 120V
Accessories for ceiling Mount & in-line Ventilators
*CFM/Sone ratings at 0 125" static pressure
*CFM/Sone ratings at 0 125" static pressure
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 43
BROA
N
Broan Controls
Decorator Wall Controls
Two-Function Controls
Model 68V, 68W
• Two independent, 120V, 15 amp rocker switches (20 amp total)
• Fits single-gang box
• Controls available in White (W) or Ivory (V)
Electronic Variable-Speed Decorator Wall Controls
Model 57V, 57W (3-Amp)*
• 120V, 3 amps
• Fits single-gang box
• Positive on/off action – dial for variable selection of air speeds and sound levels
• Built-in radio noise suppressor
• Controls available in White (W) or Ivory (V)
Model 72V, 72W (6-Amp)*
• 120V, 6 amps
• Other features same as model 57
Three-Function Controls
Model 66W, 66V
• Three independent, 120V, 15amp rocker switches (20 amp total)
• Fits single-gang box
• Controls available in White (W) or Ivory (V)
Decorator Time Controls
Model 59V (60 Minute)
• 120V, 20 amps; 240V, 10 amps
• Operate continuously or for any set period – Model 59V – up to 60 minutes
Model 61V , 61W (15 Minute)
• Operate for any set period up to 15 minutes (no “continuous on" position)
• Other features same as model 59
• Controls available in White (W) or Ivory (V)
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com44
Roof and Wall Caps
Model 611 Roof Cap
• For flat roof installation
• Aluminum natural finish
• For up to 8" round duct
Model 634 Roof Cap
• For 31⁄4" x 10" or up to 8" round duct
• Built-in backdraft damper and bird screen
• Steel baked black enamel finish
Model 644 Roof Cap
• Same as Model 634 except for aluminum, natural finish
Model 636 Roof Cap
• For 3" or 4" round duct
• Built-in backdraft damper and bird screen
• Steel baked black enamel finish
Model 646 Louvered Wall Cap
• For 6" duct
•White polymeric
Model 430 Short Eave Elbow
• For 31⁄4" x 10" duct
• Includes backdraft damper and grille
Model 431 Long Eave Elbow
• For 31⁄4" x 10" duct
• Includes backdraft damper and grille
Model 639 Wall Cap• For 31⁄4" x 10" duct • Spring-loaded backdraft damper • Built in bird screen • Steel baked black enamel finish
Model 649 Wall Cap• Same as Model 639 except
aluminum, natural finish
Model 640 Wall Cap• For 3" round duct • Built-in bird screen – no damper • Steel baked black enamel finish
Model 642 Wall Cap• For 3" or 4" duct • 4" to 3" transition included • Built-in damper • Aluminum, natural finish
Model 641 & 843BL Wall Cap• For 6" round duct • Built-in backdraft damper and
bird screen • Aluminum, natural
finish (641) or black finish (843BL)
Model 647 Wall Cap• For 7" round duct • Other features same
as Model 641
Model 643 Wall Cap• For 8" round duct • Aluminum, natural finish
Model 441 Wall Cap• For 10" round duct • Aluminum, natural finish
Model 613 Wall Cap• For 12" round duct • Built-in backdraft damper
and bird screen• Aluminum, natural finish
Model441
See Greenheck Section Page 17-18 for additional roof and wall accessories.
Model613
Model643
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 45
Pric
e
Price Industries
Fixed Blade Return Grilles and Registers Model 530 and 530D 46
Filter Return Grilles Model 530FF 47
Light Shields 47
Round Diffusers Model RCDE 49
Door/Transfer Grilles Model STG1 50
Double Deflection Supply Grilles Model 520D & Single Deflection Supply Grilles Model VM 51
High Capacity Drum Louvers Model HCD1D 56
Square Cone Diffusers Model SCD/Plaster Frames 57
Square Cone Diffusers Model SCDA Adjustable Air Pattern/Plaster Frames 59
Square Plaque Diffusers Model SPD/Plaster Frames 61
Linear Slot Diffuser Model SDS 63
Linear Slot Diffuser Plenums Model SDBI 64
T-Bar Supply Diffusers Model TBDI4 65
Perforated Supply Diffusers Model PDF/PDFE 67
Perforated Return Diffusers Model PDDR/PDDRE (Matching Return for PDF/PDFE) 70
Dampers 72
Spiral Duct Mount Grilles Model SDG 73
Louvered Face Diffusers Model SMD 73
Egg Crate Grilles Model 80/Plaster Frames 75
Round Neck Adaptors Model SR3 77
Single Duct – Controller Type SPV, SDV, SEV Series 78
Control Sequence Model SPV/SEV 82
VAV Diffuser Varitherm® Model VPD-HC 83
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com46
Fixed Blade Return Grilles and RegistersModel 530 and 530D
36 X 436 X 636 X 836 X 1036 X 1236 X 1436 X 1636 X 1836 X 2036 X 2436 X 3036 X 3648 X 648 X 1048 X 1248 X 1848 X 2048 X 2448 X 3048 X 3648 X 48
FEATURES
• All steel construction.
• Opposed blade damper, steel
• Surface mountng w/screw holes.
• B12 standard finish.
• Blade with L orientation.Model 530 and 530DReturn Air Grille Fixed Louvers,
45° Deflection, 3/4" Blade Spacing
6 X 46 X 68 X 48 X 68 X 8
10 X 410 X 510 X 610 X 810 X 1012 X 412 X 612 X 812 X 1012 X 1212 X 1812 X 2414 X 414 X 614 X 814 X 1014 X 1214 X 14
MODEL 530 (NO DAMPER)16 X 616 X 816 X 1016 X 1216 X 1416 X 1618 X 618 X 818 X 1018 X 1218 X 1418 X 1618 X 1818 X 2418 X 3020 X 620 X 820 X 1020 X 1220 X 1420 X 1620 X 1820 X 20
20 X 2424 X 424 X 624 X 8
24 X 1024 X 1224 X 1424 X 1624 X 1824 X 2024 X 2424 X 3024 X 3630 X 630 X 8
30 X 1030 X 1230 X 1430 X 1630 X 1830 X 2030 X 2430 X 30
6 X 46 X 68 X 48 X 68 X 8
10 X 410 X 610 X 810 X 1012 X 412 X 612 X 812 X 1012 X 1214 X 414 X 614 X 814 X 10
MODEL 530D (WITH DAMPER)14 X 1214 X 1416 X 616 X 816 X 1016 X 1216 X 1618 X 618 X 818 X 1018 X 1218 X 1618 X 1820 X 620 X 820 X 1020 X 1220 X 14
20 X 1620 X 1820 X 2024 X 624 X 8
24 X 1024 X 1224 X 1424 X 1624 X 1824 X 2024 X 2430 X 630 X 8
30 X 1030 X 1230 X 1430 X 16
30 X 1830 X 2030 X 2436 X 636 X 836 X 1036 X 1236 X 1636 X 1836 X 2036 X 2436 X 3048 X 1248 X 2448 X 36
22 X 422 X 622 X 8
22 X 1046 X 22
T-BAR LAYIN SIZES
22 X 622 X 1022 X 2246 X 22
530TBNo Damper
530DTBWith Damper
6 X 46 X 68 X 48 X 68 X 810 X 410 X 610 X 810 X 1012 X 412 X 612 X 812 X 1012 X 1214 X 414 X 614 X 814 X 1014 X 1214 X 14
16 X 616 X 816 X 1016 X 1216 X 1618 X 418 X 518 X 618 X 818 X 1018 X 1218 X 1418 X 1618 X 1820 X 620 X 820 X 1020 X 1220 X 1420 X 16
20 X 1820 X 2024 X 624 X 824 X 1024 X 1224 X 1424 X 1624 X 1824 X 2024 X 2426 X 1230 X 630 X 830 X 1030 X 1230 X 1430 X 1630 X 1830 X 20
30 X 24 30 X 3032 X 836 X 636 X 836 X 1036 X 1236 X 1436 X 1636 X 1836 X 2036 X 2436 X 3036 X 3648 X 1248 X 2448 X 36
6 X 46 X 68 X 48 X 68 X 810 X 410 X 510 X 610 X 810 X 1012 X 412 X 612 X 812 X 1012 X 1212 X 1812 X 2414 X 414 X 614 X 814 X 1014 X 1214 X 1416 X 616 X 8
16 X 1016 X 1216 X 1416 X 1618 X 618 X 818 X 1018 X 1218 X 1418 X 1618 X 1818 X 2418 X 3018 X 3620 X 420 X 620 X 420 X 820 X 1020 X 1220 X 1420 X 1620 X 1820 X 2020 X 24
22 X 2224 X 424 X 624 X 824 X 1024 X 1224 X 1424 X 1624 X 1824 X 2024 X 2424 X 3024 X 3630 X 630 X 830 X 1030 X 1230 X 1430 X 1630 X 1830 X 2030 X 2430 X 3034 X 1634 X 20
36 X 436 X 636 X 836 X 1036 X 1236 X 1436 X 1636 X 1836 X 2036 X 2436 X 3036 X 3648 X 648 X 848 X 1048 X 1248 X 1448 X 1648 X 1848 X 2048 X 2448 X 3048 X 3648 X 48
model 530d (WitH damPer)stoCk sizes
model 530 (no damPer)stoCk sizes
t-Bar layin - stoCk sizes
530tBno damper
530dtBWith damper
10 X 1022 X 422 X 622 X 822 X 1022 X 2246 X 22
22 X 622 X 1022 X 2246 X 22
FEATURES• All steel construction.• Opposed blade damper, steel• Surface mountng w/screw holes.• B12 standard finish.• Blade with L orientation.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 47
Pric
e
Filter Return Grilles Model 530FF
FEATURES
• Steel construction.
• Lay-in mounting, 24 X 24 module with20 X 20 filter size.
• B12 standard finish.
Model 530FF3/4" Blade Spacing, 45° Deflection
20 X 1620 X 2024 X 1224 x 1624 X 2425 X 1625 X 20
SURFACE MOUNT SIZES
24 X 12–20 X 8
24 X 24–20 X 20
TB – LAYIN SIZES
TB Border
FEATURES
• Steel construction.
• Lay-in mounting, 24 X 24 module with20 X 20 filter size.
• B12 standard finish.
Model 530FF3/4" Blade Spacing, 45° Deflection
20 X 1620 X 2024 X 1224 x 1624 X 2425 X 1625 X 20
SURFACE MOUNT SIZES
24 X 12–20 X 8
24 X 24–20 X 20
TB – LAYIN SIZES
TB Border
model 530ffstoCk sizes
t-Bar layinstoCk sizes
liGHt sHieldstoCk sizes
24 X 12–20 X 8
24 X 24–20 X 20
22 X 22
20 X 1620 X 2020 X 1220 X 1624 X 1224 X 1624 X 2425 X 1625 X 20
FEATURES• Steel construction.• Surface mount (or)• Lay-in mounting, 24 X 24 module with
20 X 20 filter size.• B12 standard finish.
FEATURES
• Steel construction.
• Lay-in mounting, 24 X 24 module with20 X 20 filter size.
• B12 standard finish.
Model 530FF3/4" Blade Spacing, 45° Deflection
20 X 1620 X 2024 X 1224 x 1624 X 2425 X 1625 X 20
SURFACE MOUNT SIZES
24 X 12–20 X 8
24 X 24–20 X 20
TB – LAYIN SIZES
TB Bordert-Bar Border
Light Shields
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com48
Return Grilles Model 530, 530D & 530FF
PERFORMAnCE DATA
44
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
6 X 6
7 X 6
8 X 6
10 X 6
12 X 6
8 X 8
14 X 6
10 X 8
16 X 6
18 X 6
12 X 8
20 X 6
14 X 8
22 X 6
16 X 8
26 X 6
18 X 8
30 X 6
22 X 8
20 X 10
16 X 12
22 X 10
18 X 12
26 X 10
22 X 12
30 X 10
24 X 12
34 X 10
28 X 12
32 X 12
28 X 14
36 X 12
30 X 14
34 X 14
30 X 16
40 X 14
34 X 16
40 X 16
36 X 18
44 X 16
40 X 18
48 X 18
42 X 20
52 X 18
48 X 20
NC 20
0.15
0.18
0.22
0.26
0.30
0.34
0.39
0.46
0.52
0.60
0.69
0.81
0.91
1.07
1.18
1.34
1.60
1.80
2.08
2.45
2.78
3.11
3.61
4.29
4.65
5.58
6.25
200.002.011
GRILLES ANDREGISTERS
NECK AREA SQ. FT.NOMINAL SIZE
CORE VELOCITYPRESSURE
NEGATIVE SP
30
-
36
-
44
-
52
-
60
-
68
-
78
-
92
-
104
-
120
-
138
-
162
-
182
-
214
-
236
-
268
-
320
-
360
-
416
-
490
-
556
-
622
-
722
-
858
-
930
-
1116
-
1250
-
45
-
54
-
66
-
78
-
90
-
102
-
117
-
138
-
156
-
180
-
207
-
243
-
273
-
321
-
354
-
402
-
480
-
540
-
624
-
735
-
834
-
933
-
1083
-
1287
-
1395
-
1674
15
1875
15
60
-
72
-
88
-
104
-
120
15
136
15
156
15
184
16
208
16
240
16
276
17
324
17
364
18
428
18
472
18
536
19
640
19
720
20
832
20
980
20
1112
21
1244
21
1444
22
1716
22
1860
22
2232
23
2500
23
75
19
90
19
110
20
130
20
150
21
170
21
195
21
230
22
260
22
300
23
345
23
405
23
455
24
535
24
590
25
670
25
800
25
900
26
1040
26
1225
27
1390
27
1555
27
1805
28
2145
28
2325
28
2790
29
3125
29
90
24
108
24
132
25
156
25
180
26
204
26
234
26
276
27
312
27
360
28
414
28
486
28
546
29
642
29
708
29
804
30
960
30
1080
31
1248
31
1470
32
1668
32
1866
32
2166
33
2574
33
2790
33
3348
34
3750
34
105
28
126
28
154
29
182
29
210
30
238
30
273
31
322
31
364
31
420
32
483
32
567
33
637
33
749
33
826
34
938
34
1120
35
1260
35
1456
35
1715
36
1946
36
2177
36
2527
37
3003
37
3255
38
3906
38
4375
38
120
32
144
32
176
33
208
33
240
33
272
34
312
34
368
35
416
35
480
35
552
36
648
36
728
37
856
37
944
37
1072
38
1280
38
1440
39
1664
39
1960
39
2224
40
2488
40
2888
41
3432
41
3720
41
4464
42
5000
42
135
35
162
35
198
36
234
36
270
37
306
37
351
37
414
38
468
38
540
39
621
39
729
40
819
40
963
40
1062
41
1206
41
1440
41
1620
42
1872
42
2205
43
2502
43
2799
43
3249
44
3861
44
4185
44
5022
45
5625
45
150
38
180
38
220
39
260
39
300
40
340
40
390
40
460
41
520
41
600
42
690
42
810
42
910
43
1070
43
1180
43
1340
44
1600
44
1800
45
2080
45
2450
46
2780
46
3110
46
3610
47
4290
47
4650
47
5580
48
6250
48
165
40
198
41
242
41
286
42
330
42
374
43
429
43
506
43
572
44
660
44
759
45
891
45
1001
45
1177
46
1298
46
1474
46
1760
47
1980
47
2288
48
2695
48
3058
48
3421
49
3971
49
4719
50
5115
50
6138
50
6875
51
7 X 4
6 X 5
8 X 4
7 X 5
10 X 4
8 X 5
12 X 4
10 X 5
14 X 4
16 X 4
12 X 5
18 X 4
14 X 5
20 X 4
16 X 5
24 X 4
18 X 5
28 X 4
20 X 5
30 X 4
24 X 5
36 X 4
28 X 5
40 X 4
32 X 5
42 X 4
36 X 5
34 X 6
24 X 8
38 X 6
28 X 8
44 X 6
32 X 8
50 X 6
36 X 8
58 X 6
42 X 8
50 X 8
38 X 10
56 X 8
44 X 10
48 X 10
40 X 12
56 X 10
48 X 12
56 X 12
48 X 14
60 X 12
50 X 14
60 X 14
54 X 16
72 X 14
60 X 16
10 X 10
12 X 10
14 X 10
16 X 10
12 X 12
18 X 10
14 X 12
14 X 14
16 X 14
18 X 14
16 X 16
20 X 14
18 X 16
24 X 14
20 X 16
24 X 16
20 X 18
26 X 16
24 X 18
26 X 18
24 X 20
30 X 18
28 X 20
32 X 20
30 X 22
36 X 20
32 X 22
38 X 22
36 X 24
40 X 24
32 X 30
Louvered Face Return Performance Data Models 530, 530FF
300.006.025
400.010.044
500.016.069
600.022.100
700.031.136
800.040.177
900.050.224
1000.062.277
1100.075.335
30
NC40
NC50
NC 20 30 40 50
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 49
Pric
e
FEATURES
• Steel construction.
• Two position adjustable pattern.
• Surface mounting.
• B12 standard finish.
• Auxiliary dampers available (Model VCR8E)
6 111/8 61/2 6 13/4 111/8
8 143/4 81/2 8 21/8 11/2
10 181/4 101/2 10 27/8 21/8
12 22 121/2 12 31/8 23/8
14 26 141/2 14 33/8 25/8
16 29 161/2 16 4 31/4
18 321/2 181/2 18 43/4 37/8
NominalSize A B D E F
DIMENSIONAL DATA
NC 20
6
8
10
12
14
16
18
400.010
500.016
600.023
700.031
800.040
900.051
1000.063
1200.090
1400.122
1600.160Size
Neck Velocity fpmVelocity Pressure in w.g.
.026
80
2-2-4
-
.033
140
2-4-8
-
.027
220
3-4-7
-
.026
315
3-5-8
-
.038
425
4-6-10
11
.033
560
5-7-11
16
.030
710
5-7-12
.041
100
2-3-5
-
.052
175
3-4-7
15
.043
270
3-5-8
11
.042
390
4-6-10
11
.061
530
5-8-12
18
.053
700
6-9-14
16
.048
885
6-9-15
15
.059
120
2-4-6
14
.075
210
4-5-9
21
.062
330
4-6-10
17
.060
470
5-7-12
17
.087
635
6-9-15
23
.076
840
7-10-16
22
.069
1060
7-11-18
21
.079
140
3-4-7
19
.101
245
4-6-10
26
.084
380
5-7-11
21
.081
550
6-8-13
22
.118
745
7-11-17
28
.102
980
8-12-19
27
.093
1240
9-13-21
26
.102
160
3-5-8
23
.130
280
5-7-11
31
.108
435
5-8-13
26
.105
630
6-10-15
26
.152
850
8-12-20
32
.132
1120
9-14-22
31
.120
1420
10-15-24
30
.130
180
4-5-9
26
.166
315
5-8-13
34
.138
490
6-9-15
30
.135
705
7-11-17
30
.194
955
9-14-22
36
.168
1260
10-15-24
35
.153
1590
11-17-27
34
.161
200
4-6-10
30
.205
350
6-9-14
37
.170
545
7-10-16
33
.166
785
8-12-19
33
.240
1060
10-15-24
40
.208
1400
11-17-27
39
.189
1770
12-19-30
37
.230
235
5-7-11
35
.292
420
7-11-17
44
.243
655
8-12-20
39
.236
940
10-14-23
39
.342
1270
12-18-29
46
.297
1680
14-20-33
44
.270
2120
15-22-36
43
.311
275
6-8-13
40
.397
490
8-13-20
48
.329
765
10-14-23
44
.320
1100
11-17-23
45
.465
1490
14-21-34
51
.403
1960
16-24-38
49
.366
2480
17-26-42
48
.408
315
6-10-15
44
.520
560
10-14-23
53
.432
870
11-16-26
48
.420
1255
12-19-31
49
.608
1695
16-24-39
55
.528
2240
18-27-43
53
.480
2830
20-30-48
52
Total Pressure in w.g.
Flow Rate, cfm
Radius of Diffusion, ft.
NC
Total Pressure in w.g.
Flow Rate, cfm
Radius of Diffusion, ft.
NC
Total Pressure in w.g.
Flow Rate, cfm
Radius of Diffusion, ft.
NC
Total Pressure in w.g.
Flow Rate, cfm
Radius of Diffusion, ft.
NC
Total Pressure in w.g.
Flow Rate, cfm
Radius of Diffusion, ft.
NC
Total Pressure in w.g.
Flow Rate, cfm
Radius of Diffusion, ft.
NC
Total Pressure in w.g.
Flow Rate, cfm
Radius of Diffusion, ft.
NC
30 40
50
NC 20 30 40 50
Performance Data
Round Diffusers Model RCDE
PERFORMAnCE DATA - in STOCK
dimensional data
FEATURES• Steel construction.• Two position adjustable pattern.• Surface mounting.• B12 standard finish.• Auxiliary dampers available (Model VCR8E)
RCDE Air Pattern
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com50
Door/Transfer Grilles Model STG1Steel Construction
FEATURES
• Heavy duty steel construction.
• 1-1/4" (32) flat border, both sides counter sunk screwhole fastening.
• Finish alum baked-enamel.
1.0
1.5
12 X 12
18 X 12
24 X 12
18 X 18
24 X 24
2.0
2.5
4.0
Core VelocityVelocity PressureNegative SP
Core AreaSq. Ft.
NominalSize
100
-
150
-
200
13
250
16
400
22
150
15
225
20
300
24
375
27
600
32
200
23
300
28
400
31
500
34
800
40
250
29
375
33
500
37
625
40
1000
45
300
33
450
38
600
42
750
44
1200
50
350
37
525
42
700
46
875
48
1400
54
400
41
600
45
800
49
1000
52
1600
57
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
100.0006.011
150.001.026
200.002.046
250.004.073
300.006.104
350.008.141
400.010.186
Performance DataPERFORMAnCE DATA - in STOCK
FEATURES• Heavy duty steel construction.• 1-1/4" (32) flat border, both sides
counter sunk screwhole fastening.• Auxiliary mounting frame.• Finish alum baked-enamel.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 51
Pric
e16 X 416 X 616 X 8
16 X 1016 X 1218 X 418 X 618 X 8
18 X 1018 X 12
FEATURES
• All steel construction.
• Opposed blade damper, steel.
• Surface mounting with screw holes.
• B12 standard finish, black damper.
• Front blade in vertical orientation.
Model 520DDouble Deflection 3/4" Blade Spacing
6 X 46 X 68 X 48 X 58 X 68 X 810 X 410 X 510 X 610 X 8
10 X 1012 X 412 X 612 X 8
12 X 1012 X 1214 X 614 X 8
14 X 1014 X 1214 X 14
STOCKED SIZES16 X 416 X 516 X 616 X 8
16 X 1016 X 1216 X 1618 X 418 X 618 X 8
18 X 1018 X 1218 X 1820 X 420 X 620 X 8
20 X 1020 X 12
24 X 424 X 624 X 824 X 1024 X 1224 X 1424 X 2430 X 430 X 630 X 830 X 1030 X 1236 X 436 X 636 X 836 X 1036 X 1236 X 2048 X 648 X 848 X 1048 X 12
Model VM(Single Deflection)FEATURES
• All aluminum construction.
• Multishutter damper.
• Surface mounting with screw holes.
• Off-white finish.
• Blade in vertical orientation.
6 X 46 X 68 X 48 X 68 X 8
10 X 410 X 610 X 8
10 X 10
12 X 412 X 612 X 812 X 1012 X 1214 X 414 X 614 X 814 X 1014 X 1214 X 14
20 X 620 X 8
20 X 1020 X 1220 X 1424 X 624 X 8
24 X 1024 X 12
Detail ARollformed
Deflecting Blade
Detail BMulti-Shutter
Blade
D =
Nom
inal
Duc
t Siz
e
Over
all =
D +
13 /4"
(44)
Open
ing
= D
- 3 /4" (1
9)
3/4"(19)
1/4"(6)
11/4"(32)
2"(51)VCS3
OpposedBlade
DamperAttached
Double Deflection Supply Grilles Model 520D& Single Deflection Supply Grilles Model VM
6 X 46 X 68 X 48 X 68 X 810 X 410 X 510 X 610 X 810 X 1012 X 412 X 612 X 812 X 1012 X 1214 X 4 14 X 614 X 814 X 1014 X 1214 X 1416 X 416 X 5
16 X 616 X 816 X 1016 X 1216 X 1618 X 418 X 618 X 818 X 1018 X 1218 X 1820 X 420 X 620 X 820 X 1020 X 1220 X 1420 X 2022 X 624 X 424 X 624 X 824 X 10
24 X 1224 X 1424 X 1624 X 1824 X 2430 X 430 X 630 X 830 X 1030 X 1236 X 436 X 636 X 836 X 1036 X 1230 X 1630 X 1836 X 2048 X 648 X 848 X 1048 X 12
t-Bar layin sizes22 X 622 X 8
22 X 1022 X 22
model 520dstoCk sizes
t-Bar layin sizes22 X 4 22 X 6
8 X 68 X 810 X 410 X 610 X 810 X 1012 X 412 X 612 X 812 X 1214 X 414 X 6
14 X 814 X 1014 X 1214 X 1416 X 416 X 616 X 816 X 1016 X 1216 X 1418 X 618 X 8
18 X 1018 X 1220 X 620 X 820 X 1020 X 12 20 X 14 24 X 624 X 824 X 1024 X 12
FEATURES• All steel construction.• Opposed blade damper, steel.• Surface mounting with screw holes.• B12 standard finish, black damper.• Front blade in vertical orientation.
FEATURES• All aluminum construction.• Multishutter damper.• Surface mounting with screw holes.• Off-white finish.• Blade in vertical orientation.
model vm stoCk sizes
Model 520D Double Deflection 3/4" Blade Spacing
Model VM (Single Deflection)
Gril
le F
ram
e O
vera
ll =
D +
13 /4"
(45)
Gril
le F
ram
e O
vera
ll =
D +
13 /4"
(45)
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com52
Supply Grilles Models 520D & VM
NC 20
Ac=0.15 ft.2
7 X 4
6 X 5
400.010
500.016
600.022
700.030
800.040
1000.062
1200.090
1400.122
1600.159
1800.202Size
Core Velocity fpmVelocity Pressure
.024
.028
.042
80
-
5-8-14
4-6-11
3-4-7
70
-
6-8-15
5-6-12
3-4-8
90
-
7-10-17
6-8-14
3-5-9
105
-
7-11-19
6-9-15
4-5-9
120
-
8-11-20
6-9-16
4-6-10
135
-
8-12-21
6-10-17
4-6-11
155
-
9-13-23
7-10-18
4-6-11
.038
.045
.067
75
-
7-10-16
6-8-13
3-5-8
90
-
7-11-17
6-9-14
4-5-9
110
-
8-12-19
6-10-15
4-6-10
130
-
9-13-21
7-10-17
4-7-10
150
-
9-14-22
7-11-18
5-7-11
170
-
10-15-24
8-12-19
5-8-12
195
-
11-16-25
9-13-20
5-8-13
.052
.063
.093
90
-
8-12-17
6-10-14
4-6-9
110
-
9-13-19
7-10-15
4-7-10
130
-
9-15-21
7-12-17
5-7-10
155
13
10-16-23
8-13-18
5-8-11
180
13
11-17-24
9-14-19
6-8-12
205
14
12-19-26
10-15-21
6-9-13
235
14
13-19-28
10-15-22
7-10-14
.071
.085
.126
105
15
9-13-19
7-10-15
5-7-9
125
16
10-15-20
8-12-16
5-7-10
155
17
11-16-23
9-13-18
6-8-11
180
17
12-17-24
10-14-19
6-9-12
210
18
13-19-26
10-15-21
7-9-13
240
19
14-20-28
11-16-22
7-10-14
275
19
15-22-30
12-18-24
8-11-15
.094
.114
.168
120
19
11-14-20
9-11-16
5-7-10
145
20
11-16-22
9-13-18
6-8-11
175
21
13-17-24
10-14-19
6-9-12
210
21
14-19-26
11-15-21
7-9-13
240
22
15-20-28
12-16-22
8-10-14
270
23
16-22-30
13-18-24
8-11-15
310
23
17-23-32
14-18-26
9-12-16
.146
.176
.261
150
26
13-16-22
10-13-18
6-8-11
180
27
14-17-24
11-14-19
7-9-12
220
27
16-19-27
13-15-22
8-10-13
260
28
17-21-29
14-17-23
8-11-15
300
29
18-23-31
14-18-25
9-11-16
340
29
20-24-33
16-19-26
10-12-17
390
30
21-26-36
17-21-29
11-13-18
.212
.256
.379
180
31
14-17-24
11-14-19
7-9-12
215
32
15-19-26
12-15-21
8-10-13
265
33
17-21-29
14-17-23
9-11-15
310
34
19-23-32
15-18-26
9-12-16
360
34
20-25-34
16-20-27
10-12-17
410
35
22-26-37
18-21-30
11-13-18
470
35
23-27-40
18-22-32
12-14-20
.287
.347
.514
210
36
15-19-26
12-15-21
8-9-13
250
37
17-21-29
14-17-23
8-10-14
310
38
19-23-32
15-18-26
9-12-16
365
38
20-25-35
16-20-28
10-13-17
420
39
22-27-37
18-22-30
11-13-19
475
40
23-28-40
18-22-32
12-14-20
545
40
25-30-42
20-24-34
12-15-21
.374
.452
.669
240
40
16-20-28
13-16-22
8-10-14
290
41
18-22-31
14-18-25
9-11-15
350
42
20-25-34
16-20-27
10-12-17
415
42
22-26-37
18-21-30
11-13-18
480
43
24-29-40
19-23-32
12-14-20
545
44
25-30-42
20-24-34
12-15-21
625
44
27-33-45
22-26-36
13-16-23
.475
.574
.850
270
44
17-22-30
14-18-24
9-11-15
325
45
19-24-33
15-19-26
10-12-16
395
45
21-26-36
17-21-29
11-13-18
470
46
23-27-40
18-22-32
12-14-20
540
47
25-30-42
20-24-34
12-15-21
610
47
26-32-45
21-26-36
13-16-22
700
48
28-35-48
22-28-38
14-17-24
Total
Pressure
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
30 40
NC 20 30 40
Louvered Face Supply520D & VM Performance Data
300.006
.014
.017
.025
45
-
4-6-12
3-5-10
2-3-6
55
-
4-7-13
3-6-10
2-3-7
65
-
4-7-14
3-6-11
2-4-7
80
-
5-8-16
4-6-13
3-4-8
90
-
5-9-17
4-7-14
3-4-8
100
-
5-9-18
4-7-14
3-4-9
115
-
6-9-19
5-7-15
3-5-10
Ac=0.18 ft.2
8 X 4
7 X 5
6 X 6
Ac=0.22 ft.2
10 X 4
8 X 5
7 X 6
Ac=0.26 ft.2
12 X 4
10 X 5
8 X 6
Ac=0.30 ft.2
14 X 4
Ac=0.34 ft.2
16 X 4
12 X 5
10 X 6
Ac=0.39 ft.2
18 X 4
14 X 5
12 X 6
8 X 8
PERFORMAnCE DATA
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 53
Pric
e
Supply Grilles Models 520D & VM
NC 20
Ac=1.18 ft.2
40 X 5 34 X 6
24 X 8 20 X 10
16 X 12 14 X 14
400.010
500.016
600.022
700.030
800.040
1000.062
1200.090
1400.122
1600.159
1800.202
Size
Core Velocity fpmVelocity Pressure
.024
.028
.042
470
-
15-23-40
12-18-32
8-11-20
535
-
16-24-42
13-19-34
8-12-21
540
-
18-26-46
14-21-37
9-13-23
720
-
19-28-48
15-22-38
9-14-24
830
-
20-30-52
16-24-42
10-15-26
980
-
22-33-57
18-26-46
11-16-28
1110
-
23-34-60
18-27-48
12-17-30
.038
.045
.067
590
14
19-28-44
15-22-35
10-14-22
670
14
20-30-47
16-24-38
10-25-23
800
15
22-32-51
18-26-41
11-16-25
900
16
24-35-55
19-28-44
12-17-27
1040
16
26-38-58
21-30-46
13-19-29
1220
17
27-40-62
22-32-50
14-20-31
1390
17
29-42-67
23-34-54
14-21-33
.052
.063
.093
710
19
23-35-48
18-28-38
12-17-24
805
20
24-37-51
19-30-41
12-18-25
960
21
27-39-56
22-31-45
13-20-28
1080
21
29-43-59
23-34-47
14-21-29
1250
22
30-44-63
24-35-50
15-22-32
1470
22
32-48-68
26-38-54
16-24-34
1670
23
35-50-73
28-40-58
17-25-37
.071
.085
.126
825
24
27-38-52
22-30-42
13-19-26
940
24
28-40-56
22-32-45
14-20-28
1120
25
31-43-60
25-34-48
15-22-30
1260
26
32-46-63
26-37-50
16-23-32
1460
26
35-49-68
28-39-54
17-25-34
1720
27
38-54-74
30-43-59
19-27-37
1950
28
40-57-79
32-48-63
20-28-40
.094
.114
.168
945
28
31-40-56
25-32-45
15-20-28
1070
28
35-43-59
26-34-47
16-21-29
1280
29
35-46-64
28-37-51
17-23-32
1440
30
37-49-68
30-39-54
19-24-34
1660
30
40-53-73
32-42-58
20-36-37
1960
31
43-57-80
34-46-64
22-28-40
2220
32
45-61-85
36-49-68
23-30-42
.146
.176
.261
1180
35
36-45-62
29-35-50
18-22-31
1340
35
39-47-65
31-38-52
19-23-33
1600
36
45-51-72
34-41-58
21-26-36
1800
37
45-55-76
36-44-61
22-27-38
2080
37
48-59-82
38-47-66
24-29-41
2450
38
52-64-89
42-51-71
26-32-45
2780
38
55-68-95
44-54-76
28-34-47
.212
.256
.379
1420
40
40-48-67
32-38-54
20-24-34
1610
41
42-52-72
34-42-58
21-26-36
1920
42
46-56-79
37-45-63
23-28-39
2160
42
48-60-84
38-48-67
24-30-42
2500
43
52-64-90
42-51-72
26-32-45
2940
43
57-70-97
46-56-78
28-35-49
3340
44
60-75-104
48-60-83
30-37-52
.287
.347
.514
1650
45
43-52-73
34-42-58
21-26-36
1880
45
45-56-78
36-45-62
23-28-39
2240
46
49-61-85
39-49-68
25-30-43
2520
47
52-65-90
42-52-72
26-32-45
2910
47
56-69-97
45-55-78
28-35-48
3430
48
67-76-106
49-61-85
32-38-53
3890
49
65-81-112
52-65-90
33-40-56
.374
.452
.669
1890
49
45-56-78
36-45-62
23-28-39
2140
50
48-60-83
38-48-66
24-30-42
2560
50
53-65-91
42-52-73
26-32-46
2880
51
56-69-87
45-55-78
28-35-48
3330
51
60-75-104
48-60-83
30-37-52
3920
52
65-81-113
52-65-90
33-42-56
4450
53
70-87-122
56-70-98
35-43-61
.475
.574
.850
2120
53
48-59-83
38-47-66
24-30-41
2410
53
51-63-89
41-50-71
26-32-44
2880
54
56-69-97
45-55-78
28-35-48
3240
54
60-73-103
48-58-82
30-37-51
3740
55
64-79-110
51-63-88
32-40-55
4410
56
70-87-120
56-70-96
35-43-60
5000
56
74-93-128
59-74-102
37-46-64
Total
Pressure
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
30 40 50
NC 20 30 40 50
300.006
.014
.017
.025
335
-
10-17-34
8-14-27
5-8-17
400
-
11-18-36
9-14-29
6-9-18
480
-
13-20-40
10-16-32
6-10-20
540
-
13-21-42
10-17-34
7-11-21
625
-
14-23-45
11-18-36
7-11-23
735
-
15-25-49
12-20-39
7-12-24
835
-
16-26-52
13-21-42
8-13-26
Ac=1.34 ft.2
46 X 5 38 X 6
28 X 8 22 X 10
18 X 12 16 X 14
Ac=1.60 ft.2
44 X 6 32 X 8
26 X 10 22 X 12
18 X 14 16 X 16
Ac=1.80 ft.2
50 X 6 36 X 8
28 X 10 24 X 12
20 X 14 18 X 16
Ac=2.08 ft.2
58 X 6 42 X x8
32 X 10 28 X 12
24 X 14 20 X 16
18 X 18Ac=2.45 ft.2
48 X 8 38 X 10
32 X 12 26 X 14
24 X 16 20 X 18
Ac=2.78 ft.2
56 X 8 14 X 10
36 X 12 30 X 14
26 X 16 24 X 18
22 X 20
Louvered Face Supply520D & VM Performance DataPERFORMAnCE DATA
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com54
Supply Grilles Models 520D & VM
NC 20
Ac=0.46 ft.2
20 X 4 16 X 5
14 X 6 10 X 8
400.010
500.016
600.022
700.030
800.040
1000.062
1200.090
1400.122
1600.159
1800.202
Size
Core Velocity fpmVelocity Pressure
.024
.028
.042
185
-
9-14-25
7-11-20
5-7-12
210
-
10-15-26
8-12-21
5-7-13
240
-
11-16-28
9-13-22
5-8-14
275
-
12-17-30
10-14-24
6-9-15
325
-
13-19-33
10-15-26
6-9-16
360
-
14-20-34
11-16-27
7-10-17
430
-
15-22-38
12-18-30
7-11-19
.038
.045
.067
230
-
12-17-27
10-14-22
6-9-14
260
-
13-19-29
10-15-23
6-9-15
300
-
14-20-31
11-16-25
7-10-16
345
-
15-22-34
12-18-27
7-11-17
405
12
16-23-37
13-18-30
8-12-18
450
13
17-25-39
14-20-31
9-13-19
535
13
18-28-42
14-22-34
9-14-21
.052
.063
.093
275
15
14-22-30
11-18-24
7-11-15
310
16
15-22-32
12-18-26
8-11-16
360
16
16-24-34
13-19-27
8-12-17
415
17
18-26-37
14-21-30
9-13-18
485
18
19-28-40
15-22-32
10-14-20
540
18
21-30-42
17-24-34
10-15-21
640
19
22-33-46
18-26-37
11-17-23
.071
.085
.126
320
20
16-23-32
13-18-26
8-11-16
365
20
18-25-35
14-20-28
9-12-17
420
21
19-27-37
15-22-30
10-13-19
485
22
21-29-40
17-23-32
10-14-20
565
22
23-31-43
18-25-34
11-15-22
630
23
24-33-45
19-26-36
12-16-23
750
24
26-36-49
21-29-39
13-18-25
.094
.114
.168
370
24
19-25-35
15-20-28
10-13-17
415
24
20-26-37
16-21-30
10-13-18
480
25
22-29-40
18-23-32
11-14-20
550
26
24-31-43
19-25-34
12-15-21
650
26
26-33-46
21-26-37
13-17-23
720
27
27-35-48
22-28-38
14-17-24
855
28
29-38-53
23-30-42
14-19-26
.146
.176
.261
460
31
23-27-39
18-22-31
11-14-20
520
31
24-30-41
19-24-33
12-15-21
600
32
26-32-45
21-26-36
13-16-22
690
32
28-34-47
22-27-38
14-17-24
810
33
30-37-51
24-30-41
15-19-26
900
34
32-39-55
26-31-44
16-20-27
1070
34
35-43-59
28-34-47
17-21-29
.212
.256
.379
550
36
25-31-43
20-25-34
12-15-21
625
37
27-33-45
22-26-36
13-16-23
720
37
29-35-48
23-28-38
14-17-24
830
38
30-38-52
24-30-42
15-19-26
970
39
33-41-56
26-33-45
17-20-28
1080
39
35-43-59
28-34-47
17-21-29
1280
40
38-48-64
30-37-51
19-23-32
.287
.347
.514
645
41
27-33-46
22-26-37
14-17-23
730
41
29-35-49
22-28-39
14-18-24
840
42
31-38-52
25-30-42
15-19-26
965
43
33-40-56
26-32-45
16-20-28
1130
43
36-44-60
29-35-48
18-22-30
1260
44
37-46-63
30-37-50
19-23-32
1500
45
41-50-69
33-40-55
20-25-35
.374
.452
.669
735
45
29-35-49
23-28-39
14-18-24
830
45
31-38-52
25-30-42
15-19-26
960
46
33-40-56
26-32-45
16-20-28
1100
47
35-43-60
28-34-48
18-22-30
1300
47
38-46-64
30-37-51
19-23-32
1440
48
40-49-68
32-39-54
20-24-34
1710
49
43-53-74
34-42-59
22-27-37
.475
.574
.850
830
49
31-38-52
25-30-42
15-19-26
935
49
32-40-55
26-32-44
16-20-28
1080
50
35-43-59
28-34-47
17-21-29
1240
50
37-45-63
30-36-50
19-23-31
1460
51
40-49-68
32-39-54
20-25-34
1620
51
42-52-72
34-42-58
21-26-36-
1930
52
46-57-79
37-46-63
23-28-40
Total
Pressure
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
30 40 50
NC 20 30 40 50
300.006
.014
.017
.025
140
-
7-10-22
6-8-18
3-5-11
155
-
7-11-23
6-9-18
3-5-11
180
-
7-12-24
6-10-19
4-6-12
205
-
8-13-26
6-10-21
4-6-13
245
-
8-14-28
6-11-22
4-7-14
270
-
9-15-30
7-12-24
5-8-15
320
-
10-16-32
8-13-26
5-8-16
Ac=0.52 ft.2
24 X 4 18 X 5
16 X 6
Ac=0.60 ft.2
28 X 4 20 X 5
18 X 6 12 X 8
10 X 10
Ac=0.69 ft.2
30 X 4 24 X 5
20 X 6 14 X 8
12 X 10
Ac=0.81 ft.2
36 X 4 28 X 5
22 X 6 16 X 8
14 X 10
Ac=0.90 ft.2
40 X 4 30 X 5
26 X 6 18 X 8
16 X 10 12 X 12
Ac=1.07 ft.2
48 X 4 36 X 5
30 X 6 22 X 8
18 X 10 14 X 12
Louvered Face Supply520D & VM Performance DataPERFORMAnCE DATA
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 55
Pric
e
Supply Grilles Models 520D & VM
NC 20
Ac=3.11 ft.2
62 X 8 48 X 10
40 X 12 34 X 14
30 X 16 26 X 18
24 X 20
400.010
500.016
600.022
700.030
800.040
1000.062
1200.090
1400.122
1600.159
1800.202
Size
Core Velocity fpmVelocity Pressure
.024
.028
.042
1240
-
24-35-63
19-29-50
12-18-31
1440
-
26-38-68
21-30-54
13-19-34
1720
12
28-41-74
22-33-59
14-20-37
1880
13
29-43-78
23-34-62
15-22-39
2230
14
31-47-85
25-38-68
16-23-43
2500
14
33-49-90
26-39-72
17-25-45
.036
.045
.067
1560
18
34-45-71
27-35-57
17-22-35
1800
19
32-47-76
26-38-61
16-23-38
2140
19
35-50-83
28-40-66
17-25-42
2320
20
36-54-87
29-43-70
18-27-43
2790
20
40-59-95
32-47-76
20-30-48
3120
21
42-62-100
34-50-80
21-31-50
.052
.063
.093
1870
23
41-53-78
33-42-62
20-26-39
2170
24
38-56-84
30-45-67
19-28-42
2570
24
42-60-91
34-48-73
21-30-46
2790
25
44-65-95
35-52-76
22-32-48
3350
26
47-72-104
38-58-83
23-36-52
3750
27
50-75-103
40-60-82
25-37-51
.071
.085
.126
2180
28
47-60-84
38-48-67
23-30-42
2530
29
44-65-90
35-52-72
22-32-45
3000
29
49-71-98
39-57-78
24-35-49
3260
30
51-74-103
41-59-82
25-37-52
3910
31
55-81-113
44-65-90
28-41-57
4380
31
58-86-119
46-69-95
29-43-60
.094
.114
.168
2490
32
48-64-90
38-51-72
24-32-45
2890
33
51-69-97
41-55-78
25-35-48
3430
33
56-76-106
45-81-85
28-38-53
3720
34
58-79-110
46-63-88
29-40-55
4460
35
63-87-122
50-70-98
31-44-61
5000
35
67-93-128
54-74-102
34-46-64
.146
.176
.261
3110
39
58-72-100
46-58-80
29-36-50
3610
40
63-78-108
50-62-86
31-39-54
4290
40
69-85-118
55-68-94
34-43-59
4650
41
77-89-123
58-71-98
36-44-61
5580
41
79-97-135
63-78-108
39-49-67
6250
42
84-104-143
67-83-114
42-52-72
.212
.256
.379
3730
44
64-79-110
51-63-88
32-40-55
4330
45
69-88-118
55-69-94
35-43-59
5150
45
76-93-130
61-74-104
38-47-65
5580
46
79-97-135
63-78-108
39-49-67
6700
47
87-107-148
70-86-118
43-53-74
7500
48
92-113-156
74-90-125
46-57-78
.287
.347
.514
4350
49
69-86-118
55-69-94
35-43-59
5050
50
75-93-128
60-74-102
38-46-64
6010
50
82-102-140
66-82-112
41-51-70
6510
51
86-105-146
69-84-117
43-52-73
7810
52
93-116-160
74-93-130
47-53-80
8750
52
96-123-169
78-98-135
49-61-85
.374
.452
.669
4980
53
74-92-128
59-74-102
37-46-64
5780
54
80-99-137
64-79-110
40-50-69
6860
54
88-108-149
70-86-119
44-54-75
7440
55
91-113-156
73-90-125
46-56-78
8930
56
100-125-171
80-100-137
50-62-86
10,000
56
106-132-180
85-105-140
56-66-90
.475
.574
.850
5600
57
79-97-135
63-78-108
40-49-67
6500
57
86-105-146
69-84-117
43-52-73
7720
58
92-115-158
74-92-126
46-57-79
8370
59
96-120-164
77-96-131
48-60-82
10,000
59
106-132-180
85-105-140
53-66-90
11,200
60
112-140-192
90-112-153
56-70-96
Total
Pressure
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
CFM
NC
Throw
Ft.
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
0°
221/2°
45°
30 40 50
NC 20 30 40 50 60
300.006
.014
.017
.025
935
-
17-27-55
14-22-44
8-14-28
1080
-
18-29-59
14-23-47
9-14-29
1290
-
19-31-64
15-25-51
10-15-32
1400
-
20-33-67
16-26-54
10-16-33
1670
-
22-36-73
18-29-58
11-18-37
1880
-
23-37-78
18-30-62
12-19-39
Ac=3.61 ft.2
72 X 8 58 X 10
48 X 12 36 X 16
30 X 18 28 X 20
24 X 24
Ac=4.29 ft.2
68 X 10 56 X 12
48 X 14 42 X 16
36 X 18 32 X 20
28 X 24
Ac=4.65 ft.2
72 X 10 60 X 12
52 X 14 44 X 16
40 X 18 36 X 20
30 X 24
Ac=5.58 ft.2
72 X 12 60 X 14
54 X 16 48 X 18
42 X 20 36 X 24
Ac=6.25 ft.2
72 X 14 60 X 16
54 X 18 48 X 20
40 X 24 32 X 30
60
Louvered Face Supply520D & VM Performance DataPERFORMAnCE DATA
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com56
High Capacity Drum Louvers Model HCD1D
FEATURES• Adjustable vanes within a rotatable drum.• Drum is adjustable through 60 degrees.
Positive detent mechanism to fix drum angle setting.
• Opposed blade damper with steel construction.• Mounting frame c/w countersunk holes.
COnSTRUCTiOn• Curved outer drum and vanes extruded
aluminum, other components are steel.• B12 Standard Finish
Model HCD1
Table 1. Dimensional Data - Imperial (inches) / Metric (mm)
Size D (duct) A B C E F H
6 71/16 (179) 81/4 (210) 33/8 (86) 3 (76) 111/16 (43) 37/8 (98) 47/16 (113)
10 103/4 (273) 123/16 (310) 57/8 (149) 6 (152) 27/16 (62) 6 (152) 513/16 (148)
12 125/8 (321) 1315/16 (354) 67/8 (175) 6 (152) 3 (76) 61/16 (154) 51/4 (133)
Model HCD1
Table 1. Dimensional Data - Imperial (inches) / Metric (mm)
Size D (duct) A B C E F H
6 71/16 (179) 81/4 (210) 33/8 (86) 3 (76) 111/16 (43) 37/8 (98) 47/16 (113)
10 103/4 (273) 123/16 (310) 57/8 (149) 6 (152) 27/16 (62) 6 (152) 513/16 (148)
12 125/8 (321) 1315/16 (354) 67/8 (175) 6 (152) 3 (76) 61/16 (154) 51/4 (133)
Model HCD1
Table 1. Dimensional Data - Imperial (inches) / Metric (mm)
Size D (duct) A B C E F H
6 71/16 (179) 81/4 (210) 33/8 (86) 3 (76) 111/16 (43) 37/8 (98) 47/16 (113)
10 103/4 (273) 123/16 (310) 57/8 (149) 6 (152) 27/16 (62) 6 (152) 513/16 (148)
12 125/8 (321) 1315/16 (354) 67/8 (175) 6 (152) 3 (76) 61/16 (154) 51/4 (133)
stoCk sizes6 X 96 X 126 X 18
10 X 2012 X 20
sizeduct Velocity, FPMVelocity Pressure in w.g.
3000.006
4000.010
5000.016
6000.022
7000.031
8000.040
9000.050
10000.062
12000.090
6/9 total PressureFlow ratencthrow 150,100,50
0.046113--
15-20-29
0.077150--
19-24-33
0.12318818
21-26-37
0.16922524
24-29-41
0.23826329
25-31-44
0.30830034
27-33-47
0.38433838
29-35-50
0.47737542
30-37-53
0.69245048
33-41-58
6/12 total PressureFlow ratencthrow 150,100,50
0.042150--
16-24-33
0.070200--
22-27-38
0.11225019
25-30-43
0.15430025
27-33-47
0.21635030
29-36-51
0.27940035
31-38-54
0.34945039
33-41-58
0.43350043
35-43-61
0.62860049
38-47-67
6/18 total PressureFlow ratencthrow 150,100,50
0.037225--
19-29-41
0.061300--
26-33-47
0.09737520
30-37-53
0.13445026
33-41-58
0.18952532
36-44-62
0.24360036
38-47-67
0.30467540
41-50-71
0.37775044
43-53-74
0.54890051
47-58-81
10/24 total PressureFlow ratencthrow 150,100,50
0.028500--
26-39-61
0.046667--
35-50-70
0.07483322
44-55-78
0.1021000
2950-61-86
0.1441167
3454-66-93
0.1861334
3957-70-99
0.2321500
4361-74-105
0.2881667
4764-78-111
0.418200053
70-86-121
12/24 total PressureFlow ratencthrow 150,100,50
0.026600--
28-42-67
0.044800--
38-54-77
0.0701000
2347-61-86
0.0961200
2954-67-94
0.1351400
3559-72-102
0.1751600
3963-77-109
0.2181800
4367-81-115
0.2712000
4770-86-121
0.393240054
77-94-133
PERFORMAnCE DATA
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 57
Pric
e
SCD/31 Surface/Lay-in 12 X 12 6
SCD/31 Surface/Lay-in 12 X 12 8
SCD/31 Surface/Lay-in 24 X 24 6
SCD/31 Surface/Lay-in 24 X 24 8
SCD/31 Surface/Lay-in 24 X 24 10
SCD/31 Surface/Lay-in 24 X 24 12
SCD/31 Surface/Lay-in 24 X 24 14
FEATURES
• All steel construction.
• Fixed pattern (SCD).
• Round neck sizes.
• Lay-in models in stock. For surface mountapplications use SPF plaster frame.
• Auxiliary dampers available (VCR8E).
• B12 standard finish.Model SCD – 4 Cone
Model Mounting FaceSize
NeckSize
MODELS/SIZES AVAILABLE
FRAME SELECTION
Type 31 – Lay-in Inverted Tee Type 31 – Surface Mount w/ SPF Frame
SPF Frame
12 X 1224 X 1224 X 24
SPF STOCKED SIZES
Ceiling ModuleCeiling Opening = A
D=Nom. Duct Dia.O.D. Neck=D–1/8" (3)
B
C 15/16"(33)
Optional Fourth Cone24" x 24" (600 x 600) Size only
Min. 1"(25)
1/8" (3)
1" (25)
Ceiling Module
1/8" (3)
1" (25)
C.M. = 20" x 20" (500 x 500)
Square Cone Diffusers Model SCD/Plaster Frames
Model Mounting Face SizeNeck Size
SCD/31 Surface/Lay-in 12 X 12 6
SCD/31 Surface/Lay-in 12 X 12 8
SCD/31 Surface/Lay-in 24 X 24 6
SCD/31 Surface/Lay-in 24 X 24 8
SCD/31 Surface/Lay-in 24 X 24 10
SCD/31 Surface/Lay-in 24 X 24 12
SCD/31 Surface/Lay-in 24 X 24 14
SCD/31 Surface/Lay-in 24 X 24 15
models/sizes - in stoCk
Model scd - 3 Cone
Model scd - 4 Cone
sPf stoCk sizes
FEATURES• All steel construction.• Fixed pattern (SCD).• Round neck sizes.• Lay-in models in stock. For surface mount
applications use SPF plaster frame.• Auxiliary dampers available (VCR8E).• B12 standard finish.
frame seleCtion
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com58
Square Cone Diffusers Model SCD/Plaster Frames
6
8
400.010
500.016
600.022
700.031
800.040
900.050
1000.062
1200.090
1400.122
1600.160
ListedSize
Neck Velocity fpmVelocity Pressure in w.g.
.018
78
-
2-3-6
.029
140
-
3-4-8
.028
98
-
2-4-7
.045
175
-
3-5-10
.040
118
-
3-4-8
.065
209
-
4-6-11
.055
137
-
3-5-9
.089
244
18
5-7-12
.072
157
16
4-6-10
.116
279
22
6-8-13
.091
176
20
4-7-10
.146
314
26
6-9-14
.112
196
23
5-7-11
.181
349
29
7-10-15
.162
235
29
6-8-12
.260
419
35
8-11-16
.220
274
34
7-9-13
.354
489
40
10-12-17
.287
314
38
8-10-14
.463
558
44
11-13-18
Total Pressure
Flow Rate, cfm
NC
Throw 150, 100, 50
Total Pressure
Flow Rate, cfm
NC
Throw 150, 100, 50
6
8
10
12
14
400.010
500.016
600.022
700.031
800.040
900.050
1000.062
1200.090
1400.122
1600.160Size
Neck Velocity fpmVelocity Pressure in w.g.
.015
78
-
1-2-4
.016
140
-
2-2-5
.019
218
-
2-3-6
.023
314
-
3-4-8
.026
428
-
3-5-10
.023
98
-
1-2-4
.025
175
-
2-3-6
.030
273
-
3-4-8
.036
393
-
3-5-10
.041
535
-
4-6-12
.034
118
-
2-3-5
.037
209
-
2-4-7
.044
327
-
3-5-9
.051
471
-
4-6-11
.058
641
16
5-7-13
.046
137
-
2-3-6
.050
244
-
3-4-8
.060
382
17
4-6-10
.070
.550
19
5-7-12
.079
748
21
6-9-14
.060
157
15
2-4-7
.065
279
19
3-5-9
.078
436
21
4-6-11
.091
628
24
5-8-13
.104
855
25
6-10-15
.076
176
19
3-4-7
.082
314
22
4-6-9
.098
491
25
5-7-12
.115
707
27
6-9-14
.131
962
29
7-11-16
.094
196
22
3-4-7
.102
349
26
4-6-10
.122
545
28
5-8-12
.142
785
30
7-10-15
.162
1069
32
8-12-17
.135
235
28
4-5-8
.146
419
31
5-7-11
.175
654
34
6-9-13
.205
942
36
8-11-16
.233
1283
38
10-13-19
.183
274
33
4-6-9
.199
489
36
6-8-12
.238
763
39
8-10-14
.279
1099
41
9-12-17
.318
1497
43
11-14-20
.239
314
37
5-7-9
.260
558
40
7-9-12
.311
872
43
9-11-15
.364
1256
45
11-13-19
.415
1710
47
12-15-22
Total Pressure
Flow Rate, cfm
NC
Throw 150, 100, 50
Total Pressure
Flow Rate, cfm
NC
Throw 150, 100, 50
Total Pressure
Flow Rate, cfm
NC
Throw 150, 100, 50
Total Pressure
Flow Rate, cfm
NC
Throw 150, 100, 50
Total Pressure
Flow Rate, cfm
NC
Throw 150, 100, 50
15
.028
491
-
4-5-11
.044
614
-
4-7-13
.064
736
17
5-8-14
.087
859
22
6-9-15
.114
982
26
7-11-16
.144
1104
30
8-12-17
.178
1227
33
9-13-18
.256
1472
39
11-14-20
.348
1718
43
12-15-22
.455
1963
47
13-16-23
Total Pressure
Flow Rate, cfm
NC
Throw 150, 100, 50
PERFORMAnCE DATA – 12 X 12 FACE SiZE
PERFORMAnCE DATA – 24 X 24 FACE SiZE
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 59
Pric
e
SCD/31 Surface/Lay-in 12 X 12 6
SCD/31 Surface/Lay-in 12 X 12 8
SCD/31 Surface/Lay-in 24 X 24 6
SCD/31 Surface/Lay-in 24 X 24 8
SCD/31 Surface/Lay-in 24 X 24 10
SCD/31 Surface/Lay-in 24 X 24 12
SCD/31 Surface/Lay-in 24 X 24 14
FEATURES
• All steel construction.
• Fixed pattern (SCD).
• Round neck sizes.
• Lay-in models in stock. For surface mountapplications use SPF plaster frame.
• Auxiliary dampers available (VCR8E).
• B12 standard finish.Model SCD – 4 Cone
Model Mounting FaceSize
NeckSize
MODELS/SIZES AVAILABLE
FRAME SELECTION
Type 31 – Lay-in Inverted Tee Type 31 – Surface Mount w/ SPF Frame
SPF Frame
12 X 1224 X 1224 X 24
SPF STOCKED SIZES
Ceiling ModuleCeiling Opening = A
D=Nom. Duct Dia.O.D. Neck=D–1/8" (3)
B
C 15/16"(33)
Optional Fourth Cone24" x 24" (600 x 600) Size only
Min. 1"(25)
1/8" (3)
1" (25)
Ceiling Module
1/8" (3)
1" (25)
C.M. = 20" x 20" (500 x 500)
Square Cone Diffusers Model SCDAAdjustable Air Pattern/Plaster Frames
Model Mounting Face SizeNeck Size
SCDA/3 Surface/Lay-in 24 X 24 6
SCDA/3 Surface/Lay-in 24 X 24 8
SCDA/3 Surface/Lay-in 24 X 24 10
SCDA/3 Surface/Lay-in 24 X 24 12
SCDA/3 Surface/Lay-in 24 X 24 14
models/sizes - in stoCk
FEATURES• all steel construction.• adjustable pattern (sCda).• round neck sizes.• lay-in models in stock. for surface mount ap-
plications use sPf plaster frame.• auxiliary dampers available (vCr8e).• B12 standard finish.
Model scdA - 3 Cone
Model scdA - 4 Cone
Type 17 Narrow MemberType 3 T-Bar A = 1" (25)Type 31 Surface Mount Type 31 T-Bar A = 1" (25)
Type 17 Narrow MemberType 3 T-Bar A = 1" (25)Type 31 Surface Mount Type 31 T-Bar A = 1" (25)
sPf stoCk sizes
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com60
sizeduct Velocity, FPMVelocity Pressure in w.g.
3000.006
4000.010
5000.016
6000.022
7000.031
8000.040
9000.050
10000.062
12000.090
6/9 total PressureFlow ratencthrow 150,100,50
0.046113--
15-20-29
0.077150--
19-24-33
0.12318818
21-26-37
0.16922524
24-29-41
0.23826329
25-31-44
0.30830034
27-33-47
0.38433838
29-35-50
0.47737542
30-37-53
0.69245048
33-41-58
6/12 total PressureFlow ratencthrow 150,100,50
0.042150--
16-24-33
0.070200--
22-27-38
0.11225019
25-30-43
0.15430025
27-33-47
0.21635030
29-36-51
0.27940035
31-38-54
0.34945039
33-41-58
0.43350043
35-43-61
0.62860049
38-47-67
6/18 total PressureFlow ratencthrow 150,100,50
0.037225--
19-29-41
0.061300--
26-33-47
0.09737520
30-37-53
0.13445026
33-41-58
0.18952532
36-44-62
0.24360036
38-47-67
0.30467540
41-50-71
0.37775044
43-53-74
0.54890051
47-58-81
10/24 total PressureFlow ratencthrow 150,100,50
0.028500--
26-39-61
0.046667--
35-50-70
0.07483322
44-55-78
0.102100029
50-61-86
0.144116734
54-66-93
0.186133439
57-70-99
0.232150043
61-74-105
0.288166747
64-78-111
0.418200053
70-86-121
12/24 total PressureFlow ratencthrow 150,100,50
0.026600--
28-42-67
0.044800--
38-54-77
0.0701000
2347-61-86
0.096120029
54-67-94
0.135140035
59-72-102
0.175160039
63-77-109
0.218180043
67-81-115
0.271200047
70-86-121
0.393240054
77-94-133
PerformanCe data
Square Cone Diffusers Model SCDA
listedsize
neck Velocity, fpmVelocity Pressure, in w.g.
400.010
500.016
600.022
700.031
800.040
900.050
1000.062
1200.090
1400.122
1600.160
6
total Pressure h .016 .026 .037 .050 .066 .083 .103 .148 .202 .263
V .027 .043 .062 .084 .110 .139 .171 .247 .336 .439
Flow rate, cfm 78 98 118 137 157 176 196 235 274 314
nc h — — — — 19 23 27 33 38 43
V — 16 21 25 28 31 34 39 43 46
radius of diffusion h 1-2-4 2-2-5 2-3-6 2-3-6 3-4-7 3-4-7 3-5-7 4-6-8 4-6-9 5-7-9
Vertical throw V 4 6 7 8 8 9 9 10 11 11
8
total Pressure h .020 .032 .046 .063 .082 .104 .128 .184 .250 .327
V .034 .053 .076 .104 .136 .172 .212 .305 .415 .543
Flow rate, cfm 140 175 209 244 279 314 349 419 489 558
nc h — — — 17 22 26 30 36 41 46
V — 18 23 27 31 34 36 41 45 49
radius of diffusion h 2-3-5 2-3-7 3-4-8 3-5-8 3-5-9 4-6-9 4-7-10 5-8-11 6-8-12 7-9-12
Vertical throw V 6 7 9 9 10 11 11 12 13 14
10
total Pressure h .024 .038 .055 .075 .098 .124 .153 .220 .299 .391
V .040 .062 .090 .122 .160 .202 .249 .359 .489 .638
Flow rate, cfm 218 273 327 382 436 491 545 654 763 872
nc h — — — 20 24 28 32 38 43 48
V — 20 25 29 33 36 38 43 47 51
radius of diffusion h 2-3-7 3-4-8 3-5-9 4-6-10 4-7-11 5-8-12 6-8-12 7-9-13 8-10-14 9-11-15
Vertical throw V 7 9 10 11 12 12 13 14 15 16
12
total Pressure h .028 .044 .063 .086 .112 .141 .175 .251 .342 .447
V .046 .072 .103 .141 .184 .232 .287 .413 .562 .734
Flow rate, cfm 314 393 471 550 628 707 785 942 1099 1256
nc h — — 16 22 26 30 34 40 45 50
V 16 22 27 31 34 37 40 45 49 52
radius of diffusion h 3-4-8 3-5-10 4-6-11 5-7-12 5-8-13 6-9-14 7-10-15 8-11-16 10-12-17 11-13-19
Vertical throw V 9 10 11 12 12 13 14 15 16 17
14
total Pressure h .032 .050 .072 .098 .128 .162 .200 .287 .391 .511
V .052 .082 .118 .160 .209 .265 .327 .471 .642 .838
Flow rate, cfm 428 535 641 748 855 962 1069 1283 1497 1710
nc h — — 18 23 28 32 35 42 47 51
V 17 23 28 32 35 39 41 46 50 54
radius of diffusion h 3-5-10 4-6-12 5-7-13 6-9-14 6-10-15 7-11-16 8-12-17 10-13-19 11-14-20 12-15-22
Vertical throw V 9 10 11 12 12 13 14 15 16 17
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 61
Pric
e
DuctSize
6
8
400.010
500.016
600.022
700.031
800.040
900.050
1000.062
1200.090
1400.122
1600.160
ListedSize
Neck Velocity fpmVelocity Pressure in w.g.
.038
78
-
2-3-6
.068
140
-
3-4-8
.059
98
-
2-4-7
.106
175
-
3-5-10
.085
118
-
3-4-8
.153
209
-
4-6-11
.116
137
-
3-5-9
.208
244
-
5-7-12
.152
157
-
4-6-10
.271
279
17
6-8-13
.192
176
18
4-7-10
.343
314
22
6-9-14
.237
196
23
5-7-11
.424
349
27
7-10-15
.341
235
31
6-8-12
.610
419
36
8-11-16
.464
274
38
7-9-13
.831
489
43
10-12-17
.606
314
44
8-10-14
1.085
558
49
11-13-18
Total Pressure
Flow Rate, cfm
NC
Throw 150, 100, 50
Total Pressure
Flow Rate, cfm
NC
Throw 150, 100, 50
Performance Data – 12 X 12 Face Size
6
8
10
12
14
400.010
500.016
600.022
700.031
800.040
900.050
1000.062
1200.090
1400.122
1600.160Size
Neck Velocity fpmVelocity Pressure in w.g.
.010
78
-
1-2-4
.018
140
-
2-2-5
.029
218
-
2-3-6
.041
314
-
3-4-8
.057
428
-
3-5-10
.016
98
-
1-2-4
.029
175
-
2-3-6
.045
273
-
3-4-8
.065
393
-
3-5-10
.088
535
-
4-6-12
.023
118
-
2-3-5
.042
209
-
2-4-7
.065
327
-
3-5-9
.093
471
15
4-6-11
.127
641
18
5-7-13
.032
137
-
2-3-6
.057
244
-
3-4-8
.088
382
18
4-6-10
.127
550
21
5-7-12
.173
748
23
6-9-14
.041
157
-
2-4-6
.074
279
19
3-5-9
.115
436
22
4-6-11
.166
628
25
5-8-13
.226
855
27
6-10-15
.053
176
19
3-4-7
.093
314
23
4-6-9
.146
491
26
5-7-12
.210
707
29
6-9-14
.286
962
31
7-11-16
.065
196
22
3-4-7
.115
349
27
4-6-10
.180
545
30
5-8-12
.259
785
33
7-10-15
.353
1069
35
8-12-17
.093
235
29
4-5-8
.166
419
33
5-7-11
.259
654
36
6-9-13
.373
942
39
8-11-16
.509
1283
41
10-13-19
.127
274
34
4-6-9
.226
489
38
6-8-12
.353
763
41
8-10-14
.508
1099
44
9-12-17
.693
1497
46
11-14-20
.166
314
38
5-7-9
.295
558
43
7-9-12
.461
872
46
9-11-15
.664
1256
49
11-13-19
.905
1710
51
12-15-22
Total Pressure
Flow Rate, cfm
NC
Throw 150, 100, 50
Total Pressure
Flow Rate, cfm
NC
Throw 150, 100, 50
Total Pressure
Flow Rate, cfm
NC
Throw 150, 100, 50
Total Pressure
Flow Rate, cfm
NC
Throw 150, 100, 50
Total Pressure
Flow Rate, cfm
NC
Throw 150, 100, 50
Performance Data – 24 X 24 Face Size
Type 31Lay-in Inverted Tee 1" (25)
Model SPD
24 X 24 22 X 22 21/2 6, 8, 10, 12, 14
12 X 12 101/2 X 101/2 11/8 6, 8
CMCeiling
Opening B
DIMENSIONAL DATA
Square Plaque Diffusers Model SPD/Plaster Frames
Model sPd
CMCeiling
OpeningB Duct Size
24 X 24 22 X 22 2 ½ 6, 8, 10, 12, 14, 15
12 X 12 10 ½ X 10 ½ 1 1/8 6, 8
DiMEnSiOnAL DATA - TYPE 31STOCK SiZES
CMCeiling
OpeningB Duct Size
24 X 24 22 X 22 2 ½ 6, 8, 10, 12, 14
DiMEnSiOnAL DATA - TYPE 17STOCK SiZES
Type 17 Narrow MemberType 3 T-Bar A = 1" (25)Type 31 Surface Mount Type 31 T-Bar A = 1" (25) Type 17 Narrow MemberType 3 T-Bar A = 1" (25)Type 31 Surface Mount Type 31 T-Bar A = 1" (25)
SCD/31 Surface/Lay-in 12 X 12 6
SCD/31 Surface/Lay-in 12 X 12 8
SCD/31 Surface/Lay-in 24 X 24 6
SCD/31 Surface/Lay-in 24 X 24 8
SCD/31 Surface/Lay-in 24 X 24 10
SCD/31 Surface/Lay-in 24 X 24 12
SCD/31 Surface/Lay-in 24 X 24 14
FEATURES
• All steel construction.
• Fixed pattern (SCD).
• Round neck sizes.
• Lay-in models in stock. For surface mountapplications use SPF plaster frame.
• Auxiliary dampers available (VCR8E).
• B12 standard finish.Model SCD – 4 Cone
Model Mounting FaceSize
NeckSize
MODELS/SIZES AVAILABLE
FRAME SELECTION
Type 31 – Lay-in Inverted Tee Type 31 – Surface Mount w/ SPF Frame
SPF Frame
12 X 1224 X 1224 X 24
SPF STOCKED SIZES
Ceiling ModuleCeiling Opening = A
D=Nom. Duct Dia.O.D. Neck=D–1/8" (3)
B
C 15/16"(33)
Optional Fourth Cone24" x 24" (600 x 600) Size only
Min. 1"(25)
1/8" (3)
1" (25)
Ceiling Module
1/8" (3)
1" (25)
C.M. = 20" x 20" (500 x 500)
sPf stoCk sizes
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com62
listedsize
neck Velocity, fpmVelocity Pressure, in w.g.
400.010
500.016
600.022
700.031
800.040
900.050
1000.062
1200.090
1400.122
1600.160
6
total Pressure, in w.g. .038 .059 .085 .116 .152 .192 .237 .341 .464 .606
Flow rate, cfm 78 98 118 137 157 176 196 235 274 314
nc — — — 16 20 24 27 33 38 43
throw 150, 100, 50 2-3-6 2-4-7 3-4-8 3-5-9 4-6-10 4-7-10 5-7-11 6-8-12 7-9-13 8-10-14
8
total Pressure, in w.g. .068 .106 .153 .208 .271 .343 .424 .610 .831 1.085
Flow rate, cfm 140 175 209 244 279 314 349 419 489 558
nc — — 17 22 26 30 34 39 44 49
throw 150, 100, 50 3-4-8 3-5-10 4-6-11 5-7-12 6-8-13 6-9-14 7-10-15 8-11-16 10-12-17 11-13-18
listedsize
neck Velocity, fpmVelocity Pressure, in w.g.
400.010
500.016
600.022
700.031
800.040
900.050
1000.062
1200.090
1400.122
1600.160
6
total Pressure, in w.g. .010 .016 .023 .032 .041 .053 .065 .093 .127 .166
Flow rate, cfm 78 98 118 137 157 176 196 235 274 314
nc — — — — — 19 22 29 34 38
throw 150, 100, 50 1-2-4 1-2-4 2-3-5 2-3-6 2-4-6 3-4-7 3-4-7 4-5-8 4-6-9 5-7-9
8
total Pressure, in w.g. .018 .029 .042. .057 .074 .093 .115 .166 .226 .295
Flow rate, cfm 140 175 209 244 279 314 349 419 489 558
nc — — — — 19 23 27 33 38 43
throw 150, 100, 50 2-2-5 2-3-6 2-4-7 3-4-8 3-5-9 4-6-9 4-6-10 5-7-11 6-8-12 7-9-12
10
total Pressure, in w.g. .029 .045 .065 .088 .115 .146 .180 .259 .353 .461
Flow rate, cfm 218 273 327 382 436 491 545 654 763 872
nc — — — 18 22 26 30 36 41 46
throw 150, 100, 50 2-3-6 3-4-8 3-5-9 4-6-10 4-6-11 5-7-12 5-8-12 6-9-13 8-10-14 9-11-15
12
total Pressure, in w.g. .041 .065 .093 .127 .166 .210 .259 .373 .508 .664
Flow rate, cfm 314 393 471 550 628 707 785 942 1099 1256
nc — — 15 21 25 29 33 39 44 49
throw 150, 100, 50 3-4-8 3-5-10 4-6-11 5-7-12 5-8-13 6-9-14 7-10-15 8-11-16 9-12-17 11-13-19
14
total Pressure, in w.g. .057 .088 .127 .173 .226 .286 .353 .509 .693 .905
Flow rate, cfm 428 535 641 748 855 962 1069 1283 1497 1710
nc — — 18 23 27 31 35 41 46 51
throw 150, 100, 50 3-5-10 4-6-12 5-7-13 6-9-14 6-10-15 7-11-16 8-12-17 10-13-19 11-14-20 12-15-22
15
total Pressure, in w.g. .065 .101 .146 .199 .259 .328 .405 .584 .794 1.037
Flow rate, cfm 491 614 736 859 982 1104 1227 1472 1718 1963
nc — — 19 24 28 32 36 42 47 52
throw 150, 100, 50 4-5-11 4-7-13 5-8-14 6-9-15 7-11-16 8-12-17 9-13-18 11-14-20 12-15-22 13-16-23
Square Plaque Diffusers Model SPD
PerformanCe data 12 X 12 faCe size
PerformanCe data 24 X 24 faCe size
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 63
Pric
e
Linear Slot Diffuser Model SDSA precisely shaped aerodynamic pattern controller provides a full 180° range of air pattern adjustment from vertical to a tight ceiling hugging horizontal air pattern. The curved, aerodynamic shape of the pattern controller is essential in achieving an exceptionally tight horizontal ceiling pattern.
Pattern Adjustment
Surface Mount – ConcealedType 2 Flanged frame
1 1/8" (29) 3/4" (19)
Type W Angle End Cap
Type W End Condition
FEATURES • Solid extruded aluminum border and
frame construction.• Modern architectural design; true
flexibility of application.• 180° air pattern adjustment and
complete flow rate control with stable horizontal air pattern.
• no “lefts" or “rights" makes for simple specification and installation.
• B12 Standard Finish
Pattern Adjustment
Surface Mount – ConcealedType 2 Flanged frame
1 1/8" (29) 3/4" (19)
Type W Angle End Cap
Type W End Condition
Pattern Adjustment
Surface Mount – ConcealedType 2 Flanged frame
1 1/8" (29) 3/4" (19)
Type W Angle End Cap
Type W End Condition
no slots
Frame 2
sds100
1" (25)
2 4 ¼ (108)
DiMEnSiOnAL DATA D
48 X 2 Slot
72 X 2 Slot
STOCK SiZES
Pattern Adjustment
Surface Mount – ConcealedType 2 Flanged frame
1 1/8" (29) 3/4" (19)
Type W Angle End Cap
Type W End Condition
Border/Frame ww
2 D+1" (25)
Pattern Adjustment
Surface Mount – ConcealedType 2 Flanged frame
1 1/8" (29) 3/4" (19)
Type W Angle End Cap
Type W End Condition
slots total Pressure.004.002
.015
.009.037.022
.064
.038.098.058
.140
.084.195.115
.250
.150
2
cFM/Ft.
hV
16 32 48 64 80 96 112 128
throw 1-2-6 3-6-15 6-12-19 11-15-22 14-17-24 15-19-27 16-25-28 18-22-31
Ft. 5 11 16 19 22 24 26 28
nc — — 18 27 34 39 44 48
length, Ft. 1 2 4 8 9 10 15 20 25 30
supply -16 -11 -6 -3 -2 0 +3 +5 +6 +8
return -10 -7 -4 -2 -1 0 +2 +3 +4 +5
Non-ducted performance tables can be used to approximate performance data when contractor fabricated plenums are supplied. Plenums must be sized to achieve equal velocity along the slot length. Inlets should be sized to reduce additional contribution of sound or pressure drop.
nC CorreCtion for varioUs diffUser lenGtHs
PerformanCe data
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com64
Linear Slot Diffuser Plenums Model SDBIDrywall / Ceiling Mounted
SDBI
FEATURES PRiCE SDB linear slot plenums are an accessory for SDS linear slot diffusers designed for flexible duct connection in drywall ceiling mount applications. Unless there is access to the ceiling space, the plenum is intended to be installed during the drywall ceiling installation.
Plenum accessories save on-site fabrication and field labor. When room usage changes, plenum accessories simplify rearrangement of air distribution.
• 1/4" (6) internal insulation
Model sdBi 100
nominal lenght
no. of slots
d=nom.inlet
hheight
xWidth
48" nom.
l=48"2 8, 10, 12 10¼ 4¼
DiMEnSiOnAL DATA - in STOCK
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 65
Pric
e
T-Bar Supply Diffusers Model TBDI4
Air Pattern Split Deflection available on36"/900mm, 48"/1200mm" and60"/1500mm units.
CN – Center NotchAllows T-Bar diffuser length to be bi-sected by existingT-Bar (by others).
e.g. Allows 48" (1219) unit to be installed into two 24" (610) ceil-ing modules.
FEATURES PRiCE TBD 4 Series T-Bar diffusers have been designed to provide a tight horizontal air pattern that is suitable for VAV systems. The air pattern is field adjustable toward or away from the diffuser inlet side.
• Pattern controllers are fitted with a tight sealing extruded vinyl blade edge seal.
• 2 slot units feature an extruded aluminum center tee that has been “dropped" below the diffuser face to match the ceiling grid and provide superior performance.
• internal coated fiberglass insulation
AVAiLABLE OPTiOnS - in STOCK• Center notch (Cn) available to bisect diffuser
length (i.e. allows 48"/1200mm unit to be installed into two 24"/600mm ceiling modules).
• Aluminum Plaster Frame (APF).
MATERiAL• Shell - Coated Steel
• Pattern Controller / Center Tee - Extruded Aluminum
• Blade Gasket - Vinyl
FiniSHShell MiLL
Plenum Face / Pattern Controller Black B17
Center Tee - White Powder Coat B12
MODELS
1" (25) Slot Width insulated TBDi4100
11/2" (38) Slot Width insulated TBDi4150
Model length standard inlet With center notch inlet
410024 6, 8
48 6, 8, 10 8, 10
415024 8
48 8, 10, 12 8, 10, 12
Stock Sizes
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com66
Model tBd 4100 1" (25) slot Width
UnitSize
Neck Velocity 300 400 500 600 700 800 900 1000 1200 1400
VP, Inches WG 006 010 016 022 031 040 050 062 090 122
Length = 24"/600mmInlet = 6" (152)
Total Pressure 0 032 0 056 0 088 0 127 0 172 0 225 0 285 0 352 0 507 0 690
Flow Rate 59 78 98 118 137 157 176 196 235 274
NC -- -- 17 23 28 33 36 40 46 50
Throw 150,100,50 2-4-11 3-7-14 5-9-18 7-11-22 8-13-24 10-14-26 11-16-28 12-18-29 14-22-32 17-24-35
Length = 24"/600mmInlet = 8" (203)
Total Pressure 0 062 0 111 0 173 0 249 0 340 0 444 0 561 0 693
Flow Rate 105 140 175 209 244 279 314 349
NC -- 24 31 37 42 46 50 53
Throw 150,100,50 5-10-19 9-13-25 11-16-28 13-19-30 15-22-33 17-25-35 19-26-37 21-28-39
Length = 48"/1200mmInlet = 6" (152)
Total Pressure 0 026 0 041 0 059 0 080 0 105 0 133 0 164 0 236 0 321
Flow Rate 78 98 118 137 157 176 196 235 274
NC -- -- -- -- 17 21 25 30 35
Throw 150,100,50 1-2-9 2-4-11 2-6-13 3-8-16 4-9-18 6-10-19 7-11-20 9-13-22 10-16-23
Length = 48"/1200mmInlet = 8" (203)
Total Pressure 0 028 0 049 0 077 0 111 0 151 0 198 0 250 0 309 0 444 0 605
Flow Rate 105 140 175 209 244 279 314 349 419 489
NC -- -- -- 21 26 30 34 37 43 48
Throw 150,100,50 2-4-12 3-8-16 5-10-19 8-12-20 9-14-22 11-16-23 12-18-25 13-19-26 16-20-29 18-22-31
Length = 48"/1200mmInlet = 10" (254)
Total Pressure 0 046 0 082 0 129 0 185 0 252 0 330 0 417 0 515
Flow Rate 164 218 273 327 382 436 491 545
NC -- 18 25 31 36 40 44 47
Throw 150,100,50 5-9-18 8-12-21 10-15-23 12-18-25 14-19-27 16-21-29 18-22-31 19-23-33
Model tBd4150 1-1/2" (38) slot Width
Length = 24"/600mmInlet = 8" (203)
Total Pressure 0 039 0 069 0 107 0 154 0 210 0 274 0 347 0 428 0 617
Flow Rate 105 140 175 209 244 279 314 349 419
NC -- -- 21 27 32 36 40 44 49
Throw 150,100,50 7-11-21 9-14-25 12-18-28 14-21-30 16-23-33 19-25-35 21-26-37 23-28-39 25-30-43
Length = 48"/1200mmInlet = 8" (203)
Total Pressure 0 018 0 032 0 049 0 071 0 097 0 126 0 160 0 197 0 284 0 387
Flow Rate 105 140 175 209 244 279 314 349 419 489
NC -- -- -- -- 17 21 25 28 34 39
Throw 150,100,50 1-3-10 2-5-13 3-7-17 5-10-20 6-12-22 8-13-23 10-15-25 11-17-26 13-20-29 16-22-31
Length = 48"/1200mmInlet = 10" (254)
Total Pressure 0 029 0 052 0 081 0 116 0 158 0 207 0 262 0 323 0 465 0 633
Flow Rate 164 218 273 327 382 436 491 545 654 763
NC -- -- 16 22 27 31 35 38 44 49
Throw 150,100,50 3-6-16 5-10-21 8-13-23 10-16-25 12-18-27 14-21-29 16-22-31 17-23-33 21-25-36 22-27-39
Length = 48"/1200mmInlet = 12"(305)
Total Pressure 0 044 0 079 0 123 0 177 0 241 0 314 0 398 0 491
Flow Rate 236 314 393 471 550 628 707 785
NC -- 17 24 30 35 39 43 46
Throw 150,100,50 6-11-22 10-15-25 13-19-28 15-22-30 18-23-33 20-25-35 22-26-37 23-28-39
PerformanCe data tBd4 series - 2 slot
Performance Notes:: 1 Units tested in accordance with ASHRAE Standard 70-2006 2 Air flow is in cubic feet per minute, cfm 3 All pressures are in inches of water gauge, W G 4 Throw values are given in feet to terminal velocities of 150 fpm (minimum), 100 fpm (middle) and 50 fpm (maximum) 5 Throw data based on supply air and room air being at isothermal conditions 6 The NC values, sound pressure level, are based on a room absorption of 10 dB re 10-12 watts and one diffuser 7 Blanks indicate NC less than 15 8 Shaded area outside recommended operating range
T-Bar Supply Diffuser Model TBDI4
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 67
Pric
e
Perforated Supply Diffusers Model PDF/PDFE
FEATURES
• All steel construction.
• Removable face.
• 4 way adjustable pattern.
• Lay-in models only stocked…for surface mount application use w/SPF plaster frame.
• Auxiliary dampers available (VCR8E).
• B12 standard finish.
Model Mounting FaceSize
NeckSize
MODELS/SIZES AVAILABLE
FRAME SECTION
Surface Mount – w/ SPF Frame Lay-in – Flush Face
Model PDF
6" 12 X 12
6
300.006
400.010
500.016
600.022
700.031
800.040
900.050
1000.062
1200.090
1400.122
InletSize
Neck Velocity fpmVelocity Pressure in w.g.
.012
59
-
0-1-4
.021
78
-
1-2-6
.033
98
-
1-3-7
.047
118
19
2-4-8
.064
137
24
3-5-9
.084
157
28
4-6-10
.106
176
32
4-7-10
.131
196
35
5-7-11
.189
235
41
6-8-12
.257
274
46
7-9-13
Total Pressure in w.g.
Flow Rate, cfm
NC
Throw 4-Way
Feet
1/8" (3)
Ceiling Module
Ceiling Opening = Nom. Size + 1/4"(6)Inside Stack = Nom. Diffuser Size
Overall Opening = Nom. Diffuser = 15/16" (24)
Overall Opening = Nom. Diffuser = 15/16" (24)
1/8" (3)1/2" (13)Ref. 11/4"
(32)
1/8" (3)
1" (25)
Ceiling Module
Model Mounting FaceSize
Neck Size
PDF/3 Lay-in 12 X 12 6
PDF/3 Lay-in 24 X 24 6
PDF/3 Lay-in 20 X 20 8
PDF/3 Lay-in 24 X 24 8
PDF/3 Lay-in 20 X 20 10
PDF/3 Lay-in 24 X 24 10
PDF/3 Lay-in 24 X 24 12
PDF/3 Lay-in 24 X 24 14
PDF/3 Lay-in 24 X 24 16
PDFE/3 Lay-in 24 X 24 6
PDFE/3 Lay-in 24 X 24 8
PDFE/3 Lay-in 24 X 24 10
FEATURES • All steel construction.• Removable face.• 4 way adjustable pattern.• Lay-in models only stocked…
for surface mount application use with SPF plaster frame.
• Auxiliary dampers available (VCR8E).• B12 standard finish.
MODELS/SiZES - in STOCK
FEATURES
• All steel construction.
• Removable face.
• 4 way adjustable pattern.
• Lay-in models only stocked…for surface mount application use w/SPF plaster frame.
• Auxiliary dampers available (VCR8E).
• B12 standard finish.
Model Mounting FaceSize
NeckSize
MODELS/SIZES AVAILABLE
FRAME SECTION
Surface Mount – w/ SPF Frame Lay-in – Flush Face
Model PDF
6" 12 X 12
6
300.006
400.010
500.016
600.022
700.031
800.040
900.050
1000.062
1200.090
1400.122
InletSize
Neck Velocity fpmVelocity Pressure in w.g.
.012
59
-
0-1-4
.021
78
-
1-2-6
.033
98
-
1-3-7
.047
118
19
2-4-8
.064
137
24
3-5-9
.084
157
28
4-6-10
.106
176
32
4-7-10
.131
196
35
5-7-11
.189
235
41
6-8-12
.257
274
46
7-9-13
Total Pressure in w.g.
Flow Rate, cfm
NC
Throw 4-Way
Feet
1/8" (3)
Ceiling Module
Ceiling Opening = Nom. Size + 1/4"(6)Inside Stack = Nom. Diffuser Size
Overall Opening = Nom. Diffuser = 15/16" (24)
Overall Opening = Nom. Diffuser = 15/16" (24)
1/8" (3)1/2" (13)Ref. 11/4"
(32)
1/8" (3)
1" (25)
Ceiling Module
FRAME SELECTiOn
PDFE
FEATURES
• All steel construction.
• Removable face.
• 4 way adjustable pattern.
• Lay-in models only stocked…for surface mount application use w/SPF plaster frame.
• Auxiliary dampers available (VCR8E).
• B12 standard finish.
Model Mounting FaceSize
NeckSize
MODELS/SIZES AVAILABLE
FRAME SECTION
Surface Mount – w/ SPF Frame Lay-in – Flush Face
Model PDF
6" 12 X 12
6
300.006
400.010
500.016
600.022
700.031
800.040
900.050
1000.062
1200.090
1400.122
InletSize
Neck Velocity fpmVelocity Pressure in w.g.
.012
59
-
0-1-4
.021
78
-
1-2-6
.033
98
-
1-3-7
.047
118
19
2-4-8
.064
137
24
3-5-9
.084
157
28
4-6-10
.106
176
32
4-7-10
.131
196
35
5-7-11
.189
235
41
6-8-12
.257
274
46
7-9-13
Total Pressure in w.g.
Flow Rate, cfm
NC
Throw 4-Way
Feet
1/8" (3)
Ceiling Module
Ceiling Opening = Nom. Size + 1/4"(6)Inside Stack = Nom. Diffuser Size
Overall Opening = Nom. Diffuser = 15/16" (24)
Overall Opening = Nom. Diffuser = 15/16" (24)
1/8" (3)1/2" (13)Ref. 11/4"
(32)
1/8" (3)
1" (25)
Ceiling Module
Model PDFEModel PDF
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com68
Perforated Supply Diffusers Model PDF/PDFE
InletSize
Neck Velocity, fpm
Velocity Pressure, In. w.g.
300
.006
400
.010
500
.016
600
.022
700
.031
800
.040
900
.050
1000
.062
1200
.090
1400
.122
8
Total Pressure, In. w.g.
Flow Rate, cfm
NC
.017
105
—
.029
140
—
.046
175
21
.066
209
26
.090
244
31
.118
279
35
.149
314
39
.184
349
42
.265
419
48
.360
489
52
Throw
4-Way
3-Way
2-Way
1-Way
1-2-7
1-2-8
1-3-11
2-4-13
2-3-9
2-4-11
2-6-14
3-7-18
2-5-10
3-7-12
4-9-16
5-11-20
3-7-11
4-8-13
6-11-18
7-13-22
5-8-12
6-9-14
8-12-19
10-15-24
6-9-13
7-11-15
9-14-20
12-18-26
7-10-14
8-11-16
11-15-22
13-19-27
7-10-14
9-12-17
12-16-23
15-20-29
9-11-16
11-13-19
14-18-25
18-22-31
10-12-17
12-14-20
16-19-27
19-24-34
10
Total Pressure, In. w.g.
Flow Rate In cfm
NC
.022
164
—
.039
218
19
.061
273
26
.088
327
31
.119
382
36
.156
436
40
.197
491
44
.243
545
47
.350
654
53
.477
763
57
Throw
4-Way
3-Way
2-Way
1-Way
1-3-9
2-4-11
2-5-14
3-6-18
3-6-11
3-7-14
4-9-18
5-11-23
4-7-13
5-9-15
6-12-20
8-15-25
6-9-14
7-11-17
9-14-22
11-18-28
7-10-15
8-13-18
11-17-24
14-21-30
8-11-16
10-14-19
13-18-26
16-23-32
9-12-17
11-14-20
14-19-27
18-24-34
10-13-18
12-15-21
16-20-29
20-25-36
11-14-20
14-17-23
18-22-31
23-28-39
12-15-21
15-18-25
19-24-34
24-30-42
PerformanCe data – 20" X 20" modUle
FEATURES
• All steel construction.
• Removable face.
• 4 way adjustable pattern.
• Lay-in models only stocked…for surface mount application use w/SPF plaster frame.
• Auxiliary dampers available (VCR8E).
• B12 standard finish.
Model Mounting FaceSize
NeckSize
MODELS/SIZES AVAILABLE
FRAME SECTION
Surface Mount – w/ SPF Frame Lay-in – Flush Face
Model PDF
6" 12 X 12
6
300.006
400.010
500.016
600.022
700.031
800.040
900.050
1000.062
1200.090
1400.122
InletSize
Neck Velocity fpmVelocity Pressure in w.g.
.012
59
-
0-1-4
.021
78
-
1-2-6
.033
98
-
1-3-7
.047
118
19
2-4-8
.064
137
24
3-5-9
.084
157
28
4-6-10
.106
176
32
4-7-10
.131
196
35
5-7-11
.189
235
41
6-8-12
.257
274
46
7-9-13
Total Pressure in w.g.
Flow Rate, cfm
NC
Throw 4-Way
Feet
1/8" (3)
Ceiling Module
Ceiling Opening = Nom. Size + 1/4"(6)Inside Stack = Nom. Diffuser Size
Overall Opening = Nom. Diffuser = 15/16" (24)
Overall Opening = Nom. Diffuser = 15/16" (24)
1/8" (3)1/2" (13)Ref. 11/4"
(32)
1/8" (3)
1" (25)
Ceiling Module
PerformanCe data – 12" X 12" modUle
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 69
Pric
e
6
8
10
12
14
16
300.006
400.010
500.016
600.022
700.031
800.040
900.050
1000.062
1200.090
1400.122Size
Neck Velocity fpmVelocity Pressure in w.g.
.009
59
-
0-0-2
0-0-2
0-1-2
0-1-3
.013
105
-
0-1-4
1-1-5
1-2-6
1-2-8
.017
164
-
1-2-8
1-2-10
1-3-13
2-4-16
.021
236
-
2-4-11
2-4-13
3-6-17
3-7-21
.025
321
-
3-6-14
3-7-16
4-10-22
5-12-27
.028
368
16
3-7-15
4-8-18
5-11-23
6-14-29
.016
78
-
0-1-3
0-1-3
0-1-4
1-1-5
.023
140
-
1-2-7
1-2-8
1-3-11
2-3-14
.030
218
16
2-4-11
2-4-14
3-6-18
3-7-23
.037
314
20
3-6-14
3-8-16
5-10-22
6-13-27
.045
428
24
5-9-16
6-11-19
8-15-25
10-18-32
.050
491
25
6-10-17
7-12-20
9-16-27
11-20-34
.026
98
-
0-1-4
1-1-5
1-2-7
1-2-8
.036
175
18
1-3-9
1-3-10
2-4-14
2-5-17
.047
273
23
2-6-13
3-7-15
4-9-20
5-11-25
.058
393
27
4-9-15
5-11-18
7-14-24
9-18-30
.070
535
30
7-12-18
9-14-21
12-18-28
15-23-35
.078
614
32
9-13-19
10-15-23
14-20-30
17-26-38
.037
118
16
1-2-6
1-2-7
1-2-10
1-3-12
.052
209
23
2-4-10
2-5-12
3-6-17
3-8-21
.067
327
28
4-8-14
4-9-17
6-12-22
7-15-28
.083
471
32
6-11-17
8-13-20
10-17-27
13-21-33
.101
641
36
9-14-19
11-16-23
15-22-31
18-27-39
.112
736
38
10-15-21
12-18-25
16-23-33
20-29-41
.050
137
21
1-2-7
1-2-9
1-3-12
2-4-15
.070
244
28
2-5-12
3-6-14
4-8-19
5-11-24
.092
382
33
5-9-15
6-11-18
8-14-24
10-18-30
.113
550
37
8-12-18
10-15-21
13-20-29
16-25-36
.137
748
41
11-15-21
13-18-25
17-24-33
22-30-42
.153
859
42
12-16-22
14-19-27
19-25-36
24-32-45
.066
157
25
1-3-8
1-3-10
2-4-13
2-5-17
.092
279
32
3-7-13
4-8-15
5-11-20
6-14-26
.120
436
37
6-10-16
8-12-19
10-16-26
13-21-32
.148
628
41
9-14-19
11-16-23
15-22-31
19-27-38
.180
855
45
12-16-22
15-19-27
20-25-36
25-32-45
.200
982
46
14-17-24
16-20-29
22-27-38
27-34-48
.083
176
29
2-3-9
2-4-11
2-5-15
3-7-19
.116
314
36
4-8-14
5-9-16
6-12-22
8-16-27
.151
491
41
8-12-17
9-14-20
12-18-27
15-23-24
.187
707
45
11-14-20
13-17-24
17-23-32
21-29-41
.227
962
49
14-17-24
16-20-28
22-27-38
27-33-47
.252
1104
50
15-18-25
18-22-30
23-29-41
29-36-51
.103
196
32
2-4-10
2-5-13
3-7-17
4-8-21
.143
349
39
5-9-14
6-10-17
8-14-23
10-17-29
.187
545
44
9-13-18
10-15-21
14-20-29
17-25-36
.231
785
48
12-15-21
14-18-26
19-24-34
23-30-43
.281
1069
52
14-18-25
17-21-30
23-28-40
29-35-50
.312
1227
53
15-19-27
19-23-32
25-30-43
31-38-54
.148
235
38
3-6-12
3-7-14
4-10-19
5-12-23
.206
419
45
7-10-16
8-12-19
11-17-25
14-21-31
.269
654
50
10-14-20
12-17-23
16-22-31
21-28-39
.332
942
54
14-17-23
16-20-28
22-27-38
27-33-47
.404
1283
57
16-19-27
19-23-33
25-31-44
32-39-55
.449
1472
59
17-21-29
20-25-35
27-33-47
34-41-59
.202
274
43
4-7-13
4-9-15
6-12-20
7-15-25
.281
489
49
8-12-17
10-14-20
13-19-27
16-24-34
.367
763
54
12-15-21
14-18-25
19-24-34
24-30-42
.452
1099
59
15-18-25
18-21-30
23-29-41
29-36-51
.550
1497
62
17-21-30
20-25-35
27-33-47
34-42-59
.611
1718
64
18-22-32
22-27-38
29-36-51
37-45-63
Total Pressure in w.g.
Flow Rate, cfm
NC
4-Way
Throw 3-Way
Feet 2-Way
1-Way
Total Pressure in w.g.
Flow Rate, cfm
NC
4-Way
Throw 3-Way
Feet 2-Way
1-Way
Total Pressure in w.g.
Flow Rate, cfm
NC
4-Way
Throw 3-Way
Feet 2-Way
1-Way
Total Pressure in w.g.
Flow Rate, cfm
NC
4-Way
Throw 3-Way
Feet 2-Way
1-Way
Total Pressure in w.g.
Flow Rate, cfm
NC
4-Way
Throw 3-Way
Feet 2-Way
1-Way
Total Pressure in w.g.
Flow Rate, cfm
NC
4-Way
Throw 3-Way
Feet 2-Way
1-Way
Perforated Supply Diffusers Model PDF/PDFE
PerformanCe data – 24" X 24" modUle
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com70
Perforated Return Diffusers Model PDDR/PDDRE(Matching Return for PDF/PDFE)
PFrF – 24 x 12 24 x 24 48 x 12. Perforated Face Panel Only – in stock
Air Flow cfm
NC
Air Flow cfm
NC
Air Flow cfm
NC
Air Flow cfm
NC
Air Flow cfm
NC
Air Flow cfm
NC
PDDR/3 Lay-in 12 X 12 6"
PDDR/3 Lay-in 24 X 24 6-18" rd.
PDDR/3 Lay-in 12 X 12 10 X 10
PDDR/3 Lay-in 24 X 12 22 X 10 sq.
PDDR/3 Lay-in 24 X 24 22 X 22 sq.
PDDR/3 Lay-in 48 X 24 46 X 22 sq.
FEATURES
• All steel construction.
• Removable face.
• Lay-in models only stocked…for surface mount use with SPF frame.
• Auxiliary dampers available.
• B12 standard finish.
Model Mounting FaceSize
NeckSize
MODELS/SIZES AVAILABLE
Model PDDR
Frame Selection – Lay-in SPF Frame
6 24 X 24
24 X 24
24 X 24
24 X 24
24 X 24
24 X 24
8
10
12
14
16
200.007.002
300.015.006
400.027.010
500.042.016
600.061.022
700.083.031
800.108.040
900.137.050
1000.169.062
NeckSize
FaceModule
Neck Velocity fpmNeg. Static Pressure
Velocity Pressure
39
-
70
-
109
-
157
-
207
-
245
-
59
-
105
-
164
-
236
-
311
-
368
-
78
-
140
-
218
-
314
-
414
-
491
-
98
-
175
-
273
-
393
-
518
-
614
-
118
-
209
-
327
-
471
-
622
-
736
-
137
-
244
-
382
-
550
-
725
-
859
-
157
-
279
-
436
-
628
-
829
-
982
16
176
-
314
-
491
-
707
16
932
18
1104
19
196
-
349
-
545
16
785
19
1036
21
1227
22
Air Flow cfm
NC6 12 X 12
200.007.002
300.015.006
400.027.010
500.042.016
600.061.022
700.083.031
800.108.040
900.137.050
1000.169.062
NeckSize
FaceModule
Neck Velocity fpmNeg. Static Pressure
Velocity Pressure
39
-
59
-
78
-
98
-
118
-
137
-
157
-
176
-
196
15
PFRF – 24 X 12 24 X 24 48 X 12 48 X 24. Perforated Face Panel Only – No Picture Available
1/8" (3)
1" (25)
Ceiling Module
Ceiling Module = A x BD =
Nom. Duct Dia.
H
O.D. Neck = D - 1/8" (3)
Diffuser Overall = A or B - 1/4" (6)
3/8" (9) Drop (Extended) Panel optional
17/16"(37)
DuctedReturnApplication
Rd Duct Connection
Max. Sq. Neck forPlenum Return
Air Flow cfm
NC
Air Flow cfm
NC
Air Flow cfm
NC
Air Flow cfm
NC
Air Flow cfm
NC
Air Flow cfm
NC
PDDR/3 Lay-in 12 X 12 6"
PDDR/3 Lay-in 24 X 24 6-18" rd.
PDDR/3 Lay-in 12 X 12 10 X 10
PDDR/3 Lay-in 24 X 12 22 X 10 sq.
PDDR/3 Lay-in 24 X 24 22 X 22 sq.
PDDR/3 Lay-in 48 X 24 46 X 22 sq.
FEATURES
• All steel construction.
• Removable face.
• Lay-in models only stocked…for surface mount use with SPF frame.
• Auxiliary dampers available.
• B12 standard finish.
Model Mounting FaceSize
NeckSize
MODELS/SIZES AVAILABLE
Model PDDR
Frame Selection – Lay-in SPF Frame
6 24 X 24
24 X 24
24 X 24
24 X 24
24 X 24
24 X 24
8
10
12
14
16
200.007.002
300.015.006
400.027.010
500.042.016
600.061.022
700.083.031
800.108.040
900.137.050
1000.169.062
NeckSize
FaceModule
Neck Velocity fpmNeg. Static Pressure
Velocity Pressure
39
-
70
-
109
-
157
-
207
-
245
-
59
-
105
-
164
-
236
-
311
-
368
-
78
-
140
-
218
-
314
-
414
-
491
-
98
-
175
-
273
-
393
-
518
-
614
-
118
-
209
-
327
-
471
-
622
-
736
-
137
-
244
-
382
-
550
-
725
-
859
-
157
-
279
-
436
-
628
-
829
-
982
16
176
-
314
-
491
-
707
16
932
18
1104
19
196
-
349
-
545
16
785
19
1036
21
1227
22
Air Flow cfm
NC6 12 X 12
200.007.002
300.015.006
400.027.010
500.042.016
600.061.022
700.083.031
800.108.040
900.137.050
1000.169.062
NeckSize
FaceModule
Neck Velocity fpmNeg. Static Pressure
Velocity Pressure
39
-
59
-
78
-
98
-
118
-
137
-
157
-
176
-
196
15
PFRF – 24 X 12 24 X 24 48 X 12 48 X 24. Perforated Face Panel Only – No Picture Available
1/8" (3)
1" (25)
Ceiling Module
Ceiling Module = A x BD =
Nom. Duct Dia.
H
O.D. Neck = D - 1/8" (3)
Diffuser Overall = A or B - 1/4" (6)
3/8" (9) Drop (Extended) Panel optional
17/16"(37)
DuctedReturnApplication
Rd Duct Connection
Max. Sq. Neck forPlenum Return
Model Mounting Face Size Neck Size
PDDR/3 Lay-in 12 X 12 6
PDDR/3 Lay-in 24 X 24 6-18 RD
PDDR/3 Lay-in 12 X 12 10 X 10
PDDR/3 Lay-in 20 X 20 12
PDDR/3 Lay-in 20 X 20 18 X 18
PDDR/3 Lay-in 24 X 12 22 X 10
PDDR/3 Lay-in 24 X 24 22 X 22
PDDR/3 Lay-in 48 X 24 46 X 22
PDDR/17 Lay-in 24 X 24 22 X 22
PDDRE/3 Lay-in 24 X 24 22 X 22
models/sizes - in stoCk
Model PDDR –Round Duct Connection
Model PDDR – Maximum SquareNeck for plenum return
Inverted T-Bar Lay-In Type 3 A = 1" (25) or 9/16"(14)
Type 17Lay-In Narrow Member 9/16"(14)
(PDDRE) Type 3 onlyDrop (Extended) Face
Model PDDR –Round Duct Connection
Model PDDR – Maximum SquareNeck for plenum return
Inverted T-Bar Lay-In Type 3 A = 1" (25) or 9/16"(14)
Type 17Lay-In Narrow Member 9/16"(14)
(PDDRE) Type 3 onlyDrop (Extended) Face
Model PDDR –Round Duct Connection
Model PDDR – Maximum SquareNeck for plenum return
Inverted T-Bar Lay-In Type 3 A = 1" (25) or 9/16"(14)
Type 17Lay-In Narrow Member 9/16"(14)
(PDDRE) Type 3 onlyDrop (Extended) Face
FEATURES • All steel construction.• Removable face.• 4 way adjustable pattern.• Lay-in models only stocked…
for surface mount application use with SPF plaster frame.
• Auxiliary dampers available.• B12 standard finish.
PerformanCe data – 12" X 12" modUle
PerformanCe data – 24" X 24" modUle
necksize
FaceModule
neck Velocity fpmneg. static Pressure
Velocity Pressure
200.007.002
300.015006
400.027.010
500.042.016
600.061.022
700.083.031
800.108.040
900.137.050
1000.169.062
6 12 x 12Air Flow cfmnc
39-
59-
78-
98-
118-
137-
157-
176-
19615
10 x 10 12 x 12Air Flow cfmnc
139-
208-
278-
347-
41618
48622
57526
62529
69431
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 71
Pric
e
Model Mounting Face Size Neck Size
PFRF Lay-in 12 X 12 -
PFRF Lay-in 24 X 24 -
PFRF Lay-in 48 X 24 -
models/sizes - in stoCk
Perforated Return Diffusers Model PDDR/PDDRE(Matching Return for PDF/PDFE)
neck size
Face Module
neck Velocity, fpm neg. static Pressure Velocity Pressure
200 .008 .002
300 .019 .006
400 .033 .010
500 .051 .016
600 .074 .022
700 .101 .031
800 .132 .040
900 .167 .050
1000.206.062
10 x 10 12 x 12 Air Flow, cfm nc
139 —
208 —
278 —
347 —
416 18
486 22
555 26
625 29
69431
18 x 18 20 x 20 Air Flow, cfm nc
450 —
675 —
900 —
1125 16
1350 21
1575 25
1800 28
2025 31
225034
22 x 10 24 x 12 Air Flow, cfm nc
306 —
458 —
611 —
764 15
917 20
1069 24
1222 27
1375 30
152833
22 x 22 24 x 24 Air Flow, cfm nc
672 —
1008 —
1344 —
1681 17
2017 22
2353 26
2689 29
3025 32
336135
46 x 22 48 x 24 Air Flow, cfm nc
1406 —
2018 —
2811 —
3514 19
4217 24
4919 28
5622 31
6325 34
702837
PerformanCe data
Perforated Return Diffusers Model PFRF
Model PFRF
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com72
Dampers
VCR 8E
VCR 9 Radial Damper
Dimensional Data —Imperial (inches) / Metric (mm)
NOMINAL SIZES
A B
6"57/8
(150)23/4
(70)
8"77/8
(200)33/4
(95)
1097/8
(250)43/4
(120)
12"117/8
(302)53/4
(146)
14"137/8
(352)63/4
(171)
Dimensional Data —Imperial (inches) / Metric (mm)
Five Segment Blades are rotatedto desired Damper Configuration
Mounting Clip
Ref. Detail ofDiffuser Neck-Inlet
Use Std. Flat Blade Screwdriverto Operate Damper
Top View of Damper
Side View of Damper
A ± 1/32
49/64"
VCR 7 Radial Opposed Blade Damper c/w Duct Ring
VCR 7 gang operated opposed blade damper supplied with duct ring. Easily adjusted with slotted operator. VCR 7 is not recommended for use with flexible duct application.
Dimensional Data — Imperial (inches) / Metric (mm)Nom. Size A B C
6 57/8" (149) 23/16" (56) 21/8" (54)8 77/8" (200) 27/8" (73) 21/8" (54)10 97/8" (251) 39/16" (90) 21/8" (54)12 117/8" (302) 45/16" (110) 21/8" (54)14 137/8" (352) 47/8" (124) 21/8" (54)15 147/8" (378) 51/8" (130) 21/8" (54)16 157/8" (403) 55/8" (143) 21/8" (54)18 177/8" (454) 61/4" (159) 21/8" (54)
Sturdy butterfly type damper provides simple and precise air volume control. Unit can be mounted directly on the diffuser face with a slotted operator. Construced of heavy gauge cold rolled steel. (Not recommended for use with flexible duct.
Duct Size A6 51/2" (140)8 71/2" (191)
10 91/2" (241)
14 131/2" (343)12 111/2" (292)
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 73
Pric
e
Spiral Duct Mount Grilles - Model SDG
Type 6*Surface Mount – BevelledNote: Extruded Aluminum Frame
* Stocked with Damper
Type 3PLay-In Inverted Tee Bar 1" (25) Panel
Frame and panel are steel construction.
Type 1Surface Mount
Core Styles Square Necks
Style/Type
Type 1 Type 33
6 X 6
9 X 9
12 X 12
15 X 15
18 X 18
6 X 6
9 X 9
15 X 15
18 X 18
9 X 9
12 X 1212 X 12
6" Ø
8" Ø10" Ø
12" Ø
14" Ø
16" Ø
Louvered Face Diffusers Model SMD
featUres
• Superior performance in exposed duct applications• Vertical front blades• Installation in round duct dia 6" - 48"• Integral gasket seals grille tightly to duct• Built in extractor to allow accurate balancing and flow• Galvanized steel construction• Includes rod operated air scoop for volume control• Mill finish
SIZE CFM RANGE SPIRAL SIZE
10 X 4 60 - 250 8" - OVER
12 X 4 75 - 300 8" - OVER
14 X 4 90 - 360 8" - OVER
16 X 4 100 - 400 8" - OVER
18 X 4 110 - 460 8" - OVER
24 X 4 150 - 620 8" - OVER
10 X 6 100 - 400 14" - OVER
12 X 6 120 - 450 14" - OVER
14 X 6 140 - 550 14" - OVER
16 X 6 150 - 600 14" - OVER
18 X 6 180 - 720 14" - OVER
24 X 6 270 - 1050 14" - OVER
10 X 8 140 - 550 22" - OVER
16 X 8 240 - 950 22" - OVER
24 X 8 350 - 1400 22" - OVER
sdG models/sizes - in stoCk
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com74
Louvered Face Diffusers Model SMD
15" X 15"
3000.036
4000.065
5000.099
6000.144
7000.196
8000.256
9000.324Size
Neck VelocityTotal Pressure
468
10
117
10-15-21
156
13-17-25
195
16-20-28
234
17-21-30
273
19-23-33
313
20-25-35
352
21-26-37
A B A B A B A B A B A B A B
625
19
781
26
938
32
1094
35
1250
40
1406
44
Total CFM
NC
CFM/Side
Throw,ft.
PERFORMANCE DATA
Duct
Area
1.56
ft2
18" X 18"
Duct
Area
2.25
ft2
6 X 6 0.73 TP Listed NC
9 X 9 0.87 TP Listed NC +2
12 X 12 0.93 TP Listed NC +4
15 X 15 1.27 TP Listed NC +4
18 X 18 1.47 TP Listed NC +6
DuctSize (-) SP
4A
675
12
169
12-17-24
225
16-19-27
281
18-22-31
338
19-24-34
394
21-26-36
450
22-27-39
506
24-29-41
A B A B A B A B A B A B A B
900
21
1125
28
1350
34
1575
38
1800
42
2025
46
Total CFM
NC
CFM/Side
Throw,ft.4A
12" X 12"300
-
75
8-12-19
100
11-15-22
125
13-17-24
150
15-19-27
175
17-20-29
200
18-22-31
225
19-23-33
A B A B A B A B A B A B A B
400
17
500
24
600
30
700
34
800
38
900
42
Total CFM
NC
CFM/Side
Throw,ft.
Duct
Area
1.00
ft2 4A
9" X 9"169
-
42
6-9-16
56
8-12-18
70
10-15-21
85
12-16-23
99
14-17-24
113
15-18-26
127
16-20-28
A B A B A B A B A B A B A B
225
14
282
21
338
27
394
31
450
35
507
39
Total CFM
NC
CFM/Side
Throw,ft.
Duct
Area
0.56
ft2 4A
6" X 6"75
-
19
4-6-12
25 31
5-8-15
38
7-10-16
44
8-12-18
50
9-14-19
56
11-15-21 12-16-22
A B A B A B A B A B A B A B
100
10
125
17
150
23
175
27
200
31
225
36
Total CFM
NC
CFM/Side
Throw,ft.
Duct
Area
0.25
ft2 4A
SMD / RETURN FACTORS
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 75
Pric
e
Egg Crate Grilles Model 80/Plaster Frames
featUres
• 1/2" x 1/2" x 1/2" aluminum grid core • Extruded aluminum borders and frames • High capacity return or exhaust outlet
and pressure drops • Ideal for pressurized ceiling return or size
restricted exhaust applications • B12 off-white finish
FEATURES
• 1/2" x 1/2" x 1/2" aluminum grid core.
• Extruded aluminum borders and frames.
• High capacity return or exhaust outlet and pressuredrops.
• Ideal for pressurized ceiling return or size restrictedexhaust applications.
• B12 off-white finish.
10 X 10
22 X 10
22 X 22
46 X 22
24 X 24
24 X 48
SIZES
T-Bar Lay-in – TB Border
Molded of light stablepolystyrene. Light weight,durable and rigid; will notwarp or discolor. An Egg-Crate cell design providesfree circulation of air.
Model #CCPTB (Egg-Crate) (Plastic)Off-set provides continuous effect.
233⁄4 X 233⁄4
473⁄4 X 233⁄4
24 X 24
48 X 24
Actual Nominal
SCD/31 Surface/Lay-in 12 X 12 6
SCD/31 Surface/Lay-in 12 X 12 8
SCD/31 Surface/Lay-in 24 X 24 6
SCD/31 Surface/Lay-in 24 X 24 8
SCD/31 Surface/Lay-in 24 X 24 10
SCD/31 Surface/Lay-in 24 X 24 12
SCD/31 Surface/Lay-in 24 X 24 14
FEATURES
• All steel construction.
• Fixed pattern (SCD).
• Round neck sizes.
• Lay-in models in stock. For surface mountapplications use SPF plaster frame.
• Auxiliary dampers available (VCR8E).
• B12 standard finish.Model SCD – 4 Cone
Model Mounting FaceSize
NeckSize
MODELS/SIZES AVAILABLE
FRAME SELECTION
Type 31 – Lay-in Inverted Tee Type 31 – Surface Mount w/ SPF Frame
SPF Frame
12 X 1224 X 1224 X 24
SPF STOCKED SIZES
Ceiling ModuleCeiling Opening = A
D=Nom. Duct Dia.O.D. Neck=D–1/8" (3)
B
C 15/16"(33)
Optional Fourth Cone24" x 24" (600 x 600) Size only
Min. 1"(25)
1/8" (3)
1" (25)
Ceiling Module
1/8" (3)
1" (25)
C.M. = 20" x 20" (500 x 500)
sUrfaCe moUnt stoCk sizes
12 X 6
SPF STOCK SiZES
12 X 1224 X 1224 X 2448 X 24
lay-in stoCk sizes
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com76
Egg-Crate Grilles Model 80/Plaster FramesPERFORMANCE DATA
75
-
90
-
110
-
130
-
150
-
170
-
195
-
230
15
260
15
300
16
345
16
405
17
450
18
535
18
590
19
670
19
800
20
900
21
1040
21
1225
22
1390
22
1555
23
1805
24
2145
24
2325
25
2790
25
3125
26
10 X 10
12 X 10
14 X 10
16 X 10
12 X 12
14 X 12
14 X 14
16 X 14
18 X 14
16 X 16
24 X 12
20 X 14
30 X 12
24 X 14
24 X 16
20 X 18
22 X 20
30 X 16
26 X 18
30 X 18
24 X 24
6 X 6
7 X 6
8 X 6
10 X 6
12 X 6
8 X 8
14 X 6
10 X 8
16 X 6
18 X 6
12 X 8
20 X 6
14 X 8
22 X 6
16 X 8
26 X 6
18 X 8
30 X 6
18 X 10
20 X 10
16 X 12
36 X 6
18 X 12
24 X 10
22 X 12
36 X 8
30 X 10
40 X 8
36 X 10
32 X 12
26 X 14
26 X 16
24 X 18
40 X 12
36 X 14
48 X 12
36 X 16
32 X 20
28 X 24
36 X 20
30 X 24
48 X 18
36 X 24
48 X 20
30 X 30
NC 20
Core AreaSquare Feet
Core Velocity Velocity Pressure
Negative SPNominal Size
0.15
0.18
0.22
0.26
0.30
0.34
0.39
0.46
0.52
0.60
0.69
0.81
0.90
1.07
1.18
1.34
1.60
1.80
2.08
2.45
2.78
3.11
3.61
4.29
4.65
5.58
6.25
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
30 40
NC 20 30 40 50 60
Egg-Crate Face 80Performace Data
300.006.014
45
-
54
-
66
-
78
-
90
-
102
-
117
-
138
-
156
-
180
-
207
-
243
-
270
-
321
-
354
-
402
-
480
-
540
-
624
-
735
-
834
-
933
-
1083
-
1287
-
1395
-
1674
-
1875
-
400.010.024
60
-
72
-
88
-
104
-
120
-
136
-
156
-
184
-
208
-
240
-
276
-
324
-
360
-
428
-
472
-
536
-
640
-
720
-
832
-
980
15
1112
15
1244
16
1444
17
1716
17
1860
18
2232
18
2500
19
500.016.038
600.022.052
90
16
108
17
132
17
156
18
180
19
204
19
234
20
276
21
312
21
360
22
414
22
486
23
540
24
642
24
708
25
804
25
960
26
1080
27
1248
27
1470
28
1668
28
1866
29
2166
30
2574
30
2790
31
3348
31
3750
32
700.031.074
105
21
126
22
154
22
182
23
210
24
238
24
273
25
322
26
364
26
420
27
483
27
567
28
630
29
749
29
826
30
938
30
1120
31
1260
32
1456
32
1715
33
1946
33
2177
34
2527
35
3003
35
3255
36
3906
36
4375
37
800.040.095
120
26
144
27
176
27
208
28
240
29
272
29
312
30
368
31
416
31
480
32
552
32
648
33
720
34
856
34
944
35
1072
35
1280
36
1440
37
1664
37
1960
38
2224
38
2488
39
2888
40
3432
40
3720
41
4464
41
5000
42
1000.062.147
150
33
180
34
220
34
260
35
300
36
340
36
390
37
460
38
520
38
600
39
690
39
810
40
900
41
1070
41
1180
42
1340
42
1600
43
1800
44
2080
44
2450
45
2780
45
3110
46
3610
47
4290
47
4650
48
5580
48
6250
49
1200.090.213
180
39
216
40
264
40
312
41
360
42
408
42
468
43
552
44
624
44
720
45
828
45
972
46
1080
47
1284
47
1416
48
1608
48
1920
49
2160
50
2496
50
2940
51
3336
51
3732
52
4332
53
5148
53
5580
54
6696
54
7500
55
1400.122.289
210
44
252
45
308
45
364
46
420
47
476
47
546
48
644
49
728
49
840
50
966
50
1134
51
1260
52
1498
52
1652
53
1876
53
2240
54
2520
55
2912
55
3430
56
3892
56
4354
57
5054
58
6006
58
6510
59
7812
59
8750
60
1500.140.332
225
46
270
47
330
47
390
48
450
49
510
49
585
50
690
51
780
51
900
52
1035
52
1215
53
1350
54
1605
54
1770
55
2010
55
2400
56
2700
57
3120
57
3675
58
4170
58
4665
59
5410
60
6435
60
6975
61
8370
61
9375
62
7 X 7
6 X 5
8 X 4
7 X 5
10 X 4
8 X 5
12 X 4
10 X 5
14 X 4
16 X 4
12 X 5
18 X 4
14 X 5
20 X 4
16 X 5
24 X 4
18 X 5
28 X 4
20 X 5
30 X 4
24 X 5
36 X 4
28 X 5
40 X 4
30 X 5
48 X 4
36 X 5
34 X 6
24 X 8
60 X 4
48 X 5
72 X 4
30 X 8
60 X 5
48 X 6
72 X 5
60 X 6
72 X 6
48 X 8
36 X 12
30 X 14
60 X 8
48 X 10
72 X 8
60 X 10
48 X 14
36 X 18
72 X 10
48 X 16
72 X 12
60 X 14
72 X 14
60 X 16
18 X 16
20 X 16
18 X 18
24 X 20
60
50
PerformaceNotes:1.) Tested per ADC Equipment code 1062: GDR-84. ASHRAE Standard 70-72. 2.) All pressures are in inches of water. 3.) Neg. SP is negative static pressure. 4.) NC valuesare based on room absorption of 10 dB.re 10
12watts. 5.) Grille tested with damper. Corrections for grille without damper: — Multiply negative static pressure by 0.92. — Subtract 4 dB from listed NC.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 77
Pric
e
Round Neck Adaptors Model SR3
1.65
3.5
1.4
3.5
1.65
3.5
1.9
1.25
3.5
2.0
1.45
3.7
2.25
1.6
1.2
3.5
2.35
1.65
1.33
7
17
4
17
7
17
9
3
17
10
5
17
11
6
3
17
12
7
4
6 X 68 X 88 X 88 X 89 X 99 X 99 X 9
10 X 1010 X 1012 X 1212 X 1212 X 1212 X 1215 X 1515 X 1518 X 1818 X 18
* 20 X 10 ** 22 X 22 *
Neck Size
66786788
1089
10121214161800
"D" Duct Size
6 X 6
9 X 9
9 X 9
12 X 12
12 X 12
15 X 15
15 X 15
15 X 15
18 X 18
18 X 18
18 X 18
21 X 21
21 X 21
21 X 21
21 X 21
24 X 24
24 X 24
24 X 24
24 X 24
5
6
8
8
10
10
12
14
12
14
16
14
16
18
20
16
18
20
22
1.10
1.15
1.10
1.15
1.10
1.15
1.10
1.05
1.15
1.10
1.10
1.15
1.10
1.10
1.05
1.15
1.10
1.10
1.05
1.10
1.15
1.10
1.15
1.10
1.15
1.10
1.05
1.15
1.10
1.10
1.15
1.10
1.10
1.05
1.15
1.10
1.10
1.05
1.15
1.20
1.10
1.20
1.15
1.20
1.15
1.10
1.20
1.15
1.10
1.20
1.15
1.10
1.10
1.20
1.15
1.15
1.10
AMD/SMDSize
RoundNeck
TPCorrection(Multiply)
NCCorrection
(Add) VT 150 VT 100 VT 50
PERFORMANCE CORRECTIONFACTORS FOR SR ADAPTORS
Throw Correction (Multiply)
* 6” through 18” starting collars available
neck size “d" duct size
6 X 6 6
8 X 8 6, 7, 8
9 X 9 6, 7 8
10 X 10 6, 8, 10
12 X 12 6, 8, 9, 10, 12
15 X 15 12, 14
18 X 18 16, 18
22 X 10 0, 6, 8, 10
22 X 22 0, 6, 8, 10, 12, 14, 16, 18PerformanCe CorreCtionfaCtors for sr adaPtors
stoCk sizes
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com78
Single Duct – Controller Type SPV, SDV, SEV Series
SPV
SDV, SEV
sPV (Pneumatic)• Fiber free foam insulation with self sealing edges
which meets requirements of UL181 • 22 ga zinc coated steel housing Mechanically
sealed and gasketed, leak resistant construction • Rectangular discharge opening with slip and drive
cleat duct connection • Control assembly will be supplied as illustrated on
right hand size unless specified otherwise • Gauge taps are standard • Pneumatic actuator supplied & mounted by Price • Clean, Dry, 20 PSI (138 KPa) control air required
sdV (ddc by Others)• Fiber free foam insulation with self sealing edges
which meets requirements of UL181 • 22 ga zinc coated steel housing Mechanicallysealed
and gasketed, leak resistant construction • Rectangular discharge opening with slip and drive-
cleat duct connection • Chicago building code controls enclosure • Actuator & controls by others
seV (Analog electronic controls) – Include SDV features and the following• Pressure independent• All control components are factory wired, calibrated
and pre-tested to ensure a fully functional unit • An electronic thermostat is furnished with each unit • Airflow adjustments can be made directly at the
thermostat
*These size are available from warehouse stock in either pressure independent pneumatic controls or set up to receive DDC controls in field Price includes (controlenclosure, 120/24 VAC transformer and disconnect)
CP 101Electronic or Digital Controls
Unit L/S CFM
Size Range Range
4 0-106 0-225
5 0-165 0-350
* 6 0-212 0-450
7 0-307 0-600
* 8 0-378 0-800
9 0-496 0-1050
* 10 0-637 0-1350
* 12 0-991 0-2100
* 14 0-1510 0-3200
16 0-1888 0-4000
B C A L
305 203 102 562
305 203 127 562
305 203 152 511
305 254 178 511
305 254 203 511
356 318 229 511
356 318 254 511
406 381 305 511
508 445 356 600
610 457 406 600
12 8 4 221/8
12 8 5 221/8
12 8 6 201/8
12 10 7 201/8
12 10 8 201/8
14 121/2 9 201/8
14 121/2 10 201/8
16 15 12 201/8
20 171/2 14 231/8
24 18 16 231/8
B C A L
Outlet Inlet Length Outlet Inlet Length
S.I. Units mm Imperial Units Inches
Unit Size L/s Min. L/s Max. cfm Min. cfm Max.
4 24 106 50 225
5 30 165 63 350
6 31 212 66 450
7 47 307 99 650
8 62 378 132 800
9 79 496 167 1050
10 104 637 221 1350
12 143 991 304 2100
14 207 1510 439 3200
16 268 1888 650 3600
Unit Size L/s Min. L/s Max. cfm Min. cfm Max.
4 24 106 50 225
5 30 165 63 350
6 31 212 66 450
7 47 307 99 650
8 62 378 132 800
9 79 496 167 1050
10 104 637 221 1350
12 143 991 304 2100
14 207 1510 439 3200
16 268 1888 650 3600
AIR VOLUME RANGES
*
*
****
* in-stock
air volUme ranGes
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 79
Pric
e
Single Duct – Controller Type SPV, SDV, SEV Series
UnitSize
4
5
6
7
8
9
10
12
14
16
Airflowcfm L/s
100113150200225100175200250300350200225300350400450250325450550650400500600700800450525650850950
1050550675750950
11501350900
1050130015001700210012001600220027003200150020002500300035004000
47537194
106478394
11814216594
106142165189212118153212260307189236283330378212248307401448496260319354448543637425496614708802991566755
103812741510708944
1180141616521888
0.010.010.010.010.010.010.010.010.010.010.010.040.050.080.110.140.180.020.030.050.070.100.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.01
2222222222291120273645461218262222222222222222222222222222222222
0.010.010.010.010.010.010.010.010.010.010.010.040.050.080.110.140.180.020.030.050.070.100.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.010.01
2222222222291120273645461218262222222222222222222222222222222222
0.090.110.190.330.410.040.100.130.200.290.390.090.110.200.270.360.450.060.100.190.290.400.070.100.140.180.230.060.080.120.190.240.290.050.070.090.140.200.270.060.080.120.160.200.310.070.110.200.300.420.060.100.150.210.290.37
22284781102102633507196222850688911315254872100162434455815202948597113182234496716213140517617285075104152538537192
––152022––––1517––––1617––151920––––15––––––––––––––15151617––161719––16192124
–16212527–1516202225151621242627192226293119212426272425262729302021222527292626272929302627303234242730313436
1719242931–2021252730212227303234252934363826293134353234363738383031323536383435363637383537394041323638404144
––––15–––––––––––––––––––––––––––––––––––––––15––161720–1516192021
–––2024––––1619––15161920–15202225–15171921–1516192020––151720211719212224252022262930212426272930
––192629––15192122151620212225192126293119212425272022242626271921222526272526272930312629323536273032343536
––––15––––1516––––1516––172022––161720––––1516––––1617–––1517201519222527151922252931
––151921––15172022––17202123–1721252616202124251719202224241719202224252122242525292226303336242630333638
–15192324–1720222426171923252629202225273022242627292526293132342526273031322729313233343034363841303436384144
Basic UnitIn
W.G. Pa
With AttenIn
W.G. Pa
0.020.030.040.050.060.020.040.050.070.090.120.080.100.160.220.170.340.060.090.150.210.290.090.130.180.230.280.060.080.110.170.200.230.080.120.140.200.270.350.110.140.200.250.310.440.100.150.250.350.470.100.160.230.310.400.50
57101215510121722302025405542851522375272223245577015202742505720303550678727355062771092537628711725405777100124
0.040.040.060.090.110.040.080.090.130.170.220.120.150.240.320.410.500.090.150.250.360.480.180.250.340.440.550.120.150.210.320.390.460.160.220.260.390.530.690.210.270.390.490.600.860.180.290.500.700.930.200.310.450.610.790.99
1010152227102022324255293660801031252136629112045628510913730375280971144055659713217252679712214921445721241742315077112152197246
1 Row CoilIn
W.G. Pa
2 Row CoilIn
W.G. Pa
Min. ΔPt.Basic UnitIn
W.G. Pa
Discharge NCBasic AssemblyΔPs Across Unit0.5" 1.5" 3"
W.G. W.G. W.G.125Pa 375Pa 750Pa
Radiated NCBasic AssemblyΔPs Across Unit0.5" 1.5" 3"W.G. W.G. W.G.
125Pa 375Pa 750Pa
Discharge NC c/w36" AttenuatorΔPs Across Unit0.5" 1.5" 3"W.G. W.G. W.G.
125Pa 375Pa 750Pa
Single Duct – Control Type SPV, SDV, SEV SeriesMinimum ΔPs Across Assembly
Performance Notes:1. NC's are derived from sound power levels, which are obtained in accordance with ARI Standard 880-98.2. Airflow is given in Litres/second, L/s and Cubic Feet/minute, CFM.3. Blank spaces indicate NC's less than 15.4. Minimum ΔPs across the unit is the lowest inlet to discharge pressure differential at which controls are
pressure independent.5. ΔPs is the difference in static pressure form inlet to discharge of the unit.6. Pressure is given in Pascals, Pa and Inches of Water Gauge, in.w.g.7. NC values are calculated based on procedures outlined in Appendix E, ARI Standard 885-98, "A Procedure
for Estimating Occupied Space Sound Levels in the Application of Air Terminals and Air Outlets." The chartto the right shows the attenuation deductions that have been used for NC calculations:
Radiated SoundTotal Deduction
All Sizes
Octave Band Mid Frequency, HZ125 250 500 1000 2000 400018 19 20 26 31 36
Discharge SoundTotal Deduction
Size 4Sizes 5, 6, 7
Octave Band Mid Frequency, HZ125 250 500 1000 2000 400022 24 36 54 60 3725 26 37 53 56 38
Sizes 8, 9, 10, 12, 14, 16 27 28 38 52 54 39
*
*
*
*
*
*
* in-stock
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com80
4, 5, 6 305 203
7, 8 305 254
9, 10 356 318
12 406 381
14 508 445
16 610 457
Unit Size B C
456789
10121416
12"(305mm)12"(305mm)12"(305mm)12"(305mm)12"(305mm)14"(356mm)14"(356mm)16"(406mm)20"(508mm)24"(610mm)
8"(203mm)8"(203mm)8"(203mm)
10"(254mm)10"(254mm)
121/2"(318mm)121/2"(318mm)15"(381mm)171/2"(445mm)18"(447mm)
4"(102mm)5"(127mm)6"(152mm)7"(178mm)8"(203mm)9"(229mm)
10"(254mm)12"(305mm)14"(356mm)16"(406mm)
UnitSize B C D
– STOCK –Optional Coil Section
c/w CAD (Coil Access Door)
Coil ConnectionsSize 4-8 1-Row – 1/2" (13) ODSize 9-16 1-Row – 7/8" (22) ODSize 4-16 2-Row – 7/8" (22) OD
Dimension "L"For 1-Row or 2-Row CoilsL=5" (127)
With Optional Access DoorFor 1-Row or 2-Row CoilsL=9" (229)
Outlet Inlet
1 & 2 ROW HOT WATER COIL DATA – STOCK SIZESTables are based on high temperature water (180°F)
1 Row
Single
Circuit
2 Row
Multi-Circuit
0.51.02.04.01.02.04.05.0
0.130.501.877.070.331.143.895.79
5.76.57.27.911.313.616.016.9
6.27.07.88.611.914.317.017.9
6.57.58.49.212.415.017.818.8
6.97.98.99.812.915.618.619.6
7.38.39.410.313.316.219.320.4
7.68.79.810.813.816.820.021.1
8.29.510.711.914.617.821.322.5
8.910.311.612.815.418.822.523.8
9.511.012.413.716.219.823.725.0
Rows GPM HD Loss 125 150 175 200 225 250 300 350 400
Inlet Size 4, 5, 6
Coil Air Flow Rate, cfm
1 Row
Single
Circuit
2 Row
Multi-Circuit
0.51.02.04.01.02.05.08.0
0.180.672.559.610.361.266.5118.14
7.68.79.810.814.818.022.625.2
8.39.610.812.015.719.224.227.1
8.910.411.713.016.620.325.728.8
9.511.112.614.017.421.327.130.3
10.111.813.415.018.122.328.431.8
11.213.215.016.819.624.130.834.5
12.314.516.618.521.025.933.137.1
13.515.818.120.222.427.635.339.6
14.617.219.621.823.829.337.542.0
Rows GPM HD Loss 200 250 300 350 400 500 600 700 800
Inlet Size 7, 8Coil Air Flow Rate, cfm
1 Row
Single
Circuit
2 Row
Multi-Circuit
1.02.04.08.02.03.05.010.0
0.220.823.1512.060.701.433.5512.15
12.213.815.416.923.926.730.435.9
13.715.717.519.325.929.033.239.3
15.017.319.421.527.731.235.742.4
16.318.921.223.529.433.138.045.2
17.620.322.925.431.135.040.247.8
18.821.824.627.232.636.842.350.4
20.023.226.229.034.238.544.352.8
21.324.627.830.835.740.346.356.2
23.727.531.034.338.843.750.359.9
Rows GPM HD Loss 300 400 500 600 700 800 900 1000 1200
Inlet Size 9, 10
Coil Air Flow Rate, cfm
1 Row
Single
Circuit
2 Row
Multi-Circuit
1.002.004.008.002.003.005.0010.00
0.281.094.1515.880.921.884.6716.00
15.217.519.721.730.334.139.046.3
16.619.221.724.032.236.341.749.7
17.920.823.526.134.038.344.252.7
19.122.325.328.135.640.246.455.5
20.223.726.930.037.142.048.558.1
22.526.430.133.640.145.452.663.1
24.729.133.237.042.948.756.467.7
26.931.736.240.445.852.060.272.2
29.234.339.243.748.755.263.976.7
Rows GPM HD Loss 400 500 600 700 800 1000 1200 1400 1600
Inlet Size 12
Coil Air Flow Rate, cfm
Access Door4” x 6.75” (102 x 171)
Single Duct – Controller Type SPV, SDV, SEV Series
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 81
Pric
e
Single Duct – Controller Type SPV, SDV, SEV SeriesSingle Duct – Controller TypeSPV, SDV Series
1 & 2 Row Hot Water Coil Data – Imperial UnitsTables are based on high temperature water (180°F)
1 Row
Single
Circuit
2 Row
Multi-Circuit
2.003.005.0010.002.003.005.0010.00
0.450.992.6510.150.561.162.869.82
24.026.028.331.439.945.252.262.5
27.029.332.135.843.148.956.868.3
29.732.435.639.745.952.360.973.5
32.335.238.843.448.555.464.778.2
34.738.041.946.951.158.468.382.7
37.240.744.950.353.661.471.887.0
39.643.347.853.656.164.375.291.2
44.448.653.760.261.270.182.099.4
49.454.059.566.766.476.088.8107.5
Rows GPM HD Loss 600 800 1000 1200 1400 1600 1800 2200 2600
Inlet Size 14
Coil Air Flow Rate, cfm
1 Row
Single
Circuit
2 Row
Multi-Circuit
2.003.005.0010.002.003.005.0010.00
0.511.133.0311.580.430.711.063.63
28.731.334.338.252.0056.7060.4072.8
31.434.337.842.355.360.464.578.0
34.037.241.146.158.363.868.282.7
36.439.944.149.661.267.071.787.2
38.742.547.153.064.070.175.191.4
41.045.150.056.366.773.278.495.5
43.347.652.859.669.476.181.699.4
45.650.255.762.872.179.184.7103.3
47.952.758.565.974.882.187.9107.2
52.657.864.172.280.288.084.2114.8
57.362.969.878.585.794.0100.6122.4
Rows GPM HD Loss 800 1000 1200 1400 1600 1800 2000 2200 2400 2800 3200
Inlet Size 16
Coil Air Flow Rate, cfm
Factor 0.32 0.40 0.48 0.56 0.64 0.80 1.00 1.12 1.20 1.28 1.44 1.60
∆T °F 40 50 60 70 80 100 125 140 150 160 180 200
Correction Factors – 1, 2 and 4 Row Hot Water Coils
Performance Notes:
1. Tabled values are in MBH (thousands of BTU per hour)
2. Tables are based on a temperature difference of 125°F (180°F entering water temperature and 55°F enteringair temperature). For other temperature differences, multiply MBH values by factors as listed above.
3. Minimum air and water flow values are based on ASHRAE recommendations for coil selection. Forselections below these tabulated air or water flow values, please consult your local Price representative.
4. Do not select coils for a leaving air temperature above 120°F.
5. HD(head) loss is in feet of water.
6. ∆Ps, is the pressure drop in inches of water across the coil.
7. For airflow static pressure loss data, see selection guide on page F-12.
8. Air temperature rise=ATR
ATR (F°) = 927 x MBH/CFM
9. Water temperature drop=WTD
WTD (F°) = 2.04 x MBH/GPM
10. Values in tables are listed for 0 feet of altitude and no glycol in the system.
11. For information outside the ranges used in the table, consult Quick Select Software or your Pricerepresentative for accurate coil information.
12. Connections:Single circuit are 1/2" OD male soder.Multi circuit are 7/8" OD male soder.
1 & 2 roW Hot Water Coil data – stoCk sizes
Performance notes:
1 Tabled values are in MBH (thousands of BTU per hour)
2 Tables are based on a temperature difference of 125°F (180°F entering water temperature and 55°F entering air temperature) For other temperature differ-ences, multiply MBH values by factors as listed above
3 Minimum air and water flow values are based on ASHRAE recommenda-tions for coil selection For selections below these tabulated air or water flow values, please consult your local Price representative
4 Do not select coils for a leaving air temperature above 120°F
5 HD(head) loss is in feet of water
6 ÆPs, is the pressure drop in inches of water across the coil
7 Air temperature rise=ATR
ATR (F°) = 927 x MBH/CFM
8 Water temperature drop=WTD
WTD (F°) = 2 04 x MBH/GPM
9 Values in tables are listed for 0 feet of altitude and no glycol in the system
10 For information outside the ranges used in the table, consult your Brucker representative for accurate coil information
11 Connections: Single circuit are 1/2" OD male soder Multi circuit are 7/8" OD male soder
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com82
Control Sequence Model SPV/SEV
sequence of operation - Pressure independent, variable volume, normally open, direct acting cooing application, with optional reheat.
An increase in space temperature increases the thermostat output pressure Wen the thermostat output increases to 13 psi or more, the VAV box damper is maintained at he preselected maximum flow setting
A decrease in space temperature decreases the thermostat output pressure Whent he thermostat output decreases to 8 psi or less, the VAV box damper is maintained at the preselected minimum flow setting
At thermostat output pressures between 8 & 13 psi the VAV damper modulates between minumum & maximum flow
At thermostat output pressures below 8 psi the minumum flow setting is main-tained, and the thermostat may control optional reheat coils
Airflow is held constant at any given thermostat output pressure regardless of changes in inlet duct static pressure
normally Open damper:
On failure of the main air supply the damper will fail to the open position
sequence of operation - Pressure independent, variable volume, cooling only.
On an increase in space temperature the space thermostat regulates control-ler/actuator to open the VAV damper and increase the flow of cool air On an increase in space temperature greater than the cooling proportional band, the airflow is maintained at a preselected maximum flow setting
On a decrease in space temperature the thermostat will regulate the controller/actuator to close the VAV damper and reduce the flow of cool air If the space temperature decreased to less than the cooling proportional band, the airflow is maintained at the preselected minimum flow setting
Airflow is held constant regardless of changes in duct static pressure
SPV Control Sequence
SEV Control Sequence
\1 \ /
control sequencePneuMAtic cOntrOls number 1008
AIR FLOW
FLOW SENSOR
NORMALLY OPEN 5-10 PSIDAMPER PNEUMATIC
ACTUATOR
GAUGE TAPS
TYPE CP101CONTROLLER8-13 PSI RESET
B
M
Go
I I I I
TO OPTIONAL REHEAT COIL I LN O 3-8 PSI HEATING VALVE,I
I T OR PE SWITCH
I I SEE WIRING DIAGRAM I I
I DIRECT ACTING MAIN AIR 1 OR2 PIPE 20 PSI THERMOSTAT
Sequence of Operation -- Pressure independent, variable1) TOTAL AIR 0 017 SCFM volume, normally open, direct acting cooling application,
optional reheat An increase in space temperature increases the thermostat outputLEGENDpressure When the thermostat output increases to 13 psi or theVAV box damper is maintained at the preselected maxirnum flow
FACTORY PNEUMATIC TUBING
------- FIELD PNEUMATIC TUBINGsetting A decrease in space temperature decreases the thermostat output
CONTROL GRAPH pressure When the thern10stat output decreases to 8 psi or less, theOPEN VAV box damper is maintained at the preselected n1inimun1 flowMax Cooling setting
At thermostat output pressures between 8 & 13 psi the VAV damper> modulates between minimum & maximum flow
At thermostat output pressures below 8 psi the minimum flow settingMin Cooling
n1aintained, and the thermostat may control optional reheat coils CLOSE Airflow is held constant at any given thermostat output pressure
Set PointCool Room Condition Warm regardless of changes in inlet duct static pressure
Normally Open Damper:C)n failure of the will fail toposn:i
SPV8 I RPV8 I LPV8
Kreuter CP101
Clg , Reheat Optional
Variable Volume
Pressure Independent
D A T'Stat, N O Damper
231691
03/07/10
SHEET 1 OF 1 REV 0 Printed in Canada
\1 \ /
control sequencePneuMAtic cOntrOls number 1008
AIR FLOW
FLOW SENSOR
NORMALLY OPEN 5-10 PSIDAMPER PNEUMATIC
ACTUATOR
GAUGE TAPS
TYPE CP101CONTROLLER8-13 PSI RESET
B
M
Go
I I I I
TO OPTIONAL REHEAT COIL I LN O 3-8 PSI HEATING VALVE,I
I T OR PE SWITCH
I I SEE WIRING DIAGRAM I I
I DIRECT ACTING MAIN AIR 1 OR2 PIPE 20 PSI THERMOSTAT
Sequence of Operation -- Pressure independent, variable1) TOTAL AIR 0 017 SCFM volume, normally open, direct acting cooling application,
optional reheat An increase in space temperature increases the thermostat outputLEGENDpressure When the thermostat output increases to 13 psi or theVAV box damper is maintained at the preselected maxirnum flow
FACTORY PNEUMATIC TUBING
------- FIELD PNEUMATIC TUBINGsetting A decrease in space temperature decreases the thermostat output
CONTROL GRAPH pressure When the thern10stat output decreases to 8 psi or less, theOPEN VAV box damper is maintained at the preselected n1inimun1 flowMax Cooling setting
At thermostat output pressures between 8 & 13 psi the VAV damper> modulates between minimum & maximum flow
At thermostat output pressures below 8 psi the minimum flow settingMin Cooling
n1aintained, and the thermostat may control optional reheat coils CLOSE Airflow is held constant at any given thermostat output pressure
Set PointCool Room Condition Warm regardless of changes in inlet duct static pressure
Normally Open Damper:C)n failure of the will fail toposn:i
SPV8 I RPV8 I LPV8
Kreuter CP101
Clg , Reheat Optional
Variable Volume
Pressure Independent
D A T'Stat, N O Damper
231691
03/07/10
SHEET 1 OF 1 REV 0 Printed in Canada
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 83
Pric
e
VAV Cooling and VAV Heating VPD-HC Varitherm® diffusers feature an architecturally appealing solid plaque design and high performance control linkage The plaque can be opened to allow easy access to temperature set point dials, and minimum airflow adjustment
Thermal actuators sense room air and adjust airflow into the space to satisfy the room load, requiring no wires for simple installation and maintenance
standard construction Features
• Steel backpan, faceplate and linkage for strength and durability
• Thermal elements for consistent, repeatable performance
• Hinged faceplate, with powerful magnetic closure ensures simple yet strong closure, that also allows for quick access to adjustment features
• Specially engineered damper stack for reduced linkage binding and superior performance over the entire operating range
standard linkage and control Features
• Individual heating and cooling set points
• Minimum airflow adjustment
• Balancing mode for easy setup
• Automatic heating /cooling changeover
• Engineered damper lift track for a more predictable linear perfor-mance and for isolating the force of the damper on the linkage for freer, smoother operation – improving the response of the diffuser to fluctuating room loads
Finish
White Powder Coat B12
VAV Diffuser Varitherm® Model VPD-HC
Ceiling Module Nominal Imperial Metric Duct
24 x 24 600 x 600 6, 8,10,12 (610x610) (152, 203, 254, 305)
Ceiling Module
Nom. Duct
Nom. Duct - 1/4" (3)
2 1/2"(64)
Diffuser Plaque
3 15/16"(101)
dimensional data - stoCk sizes
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com84
VAV Diffuser Varitherm® Model VPD-HC
Performance Notes:1. Performance data is presented for Varitherm® diffuser
at several modulated damper positions with constant duct static pressures of 0.10, 0.20, 0.30, and 0.40 inches w.g.
Performance Notes:1. Performance data is presented for the Varitherm®
diffuser with the damper in the full open (maximum fl ow) position.
2. Tested in accordance with ASHRAE Standard 70-1991 “Method of Testing for Rating the Performance of Air Outlets and Inlets”
3. Air fl ow is in cubic feet per minute, CFM.4. All pressures are in inches of water.5. Throw values are given in feet to terminal velocities of
150-100-50 fpm.6. Throw data is based on supply air and room air at
isothermal conditions.
2. Tested in accordance with ASHRAE Standard 70-1991 “Method of Testing for Rating the Performance of Air Outlets and Inlets”
3. Air fl ow is in cubic feet per minute, CFM.4. Throw values are given in feet to terminal velocities of
150-100-50 fpm.
5. Throw data is based on supply air and room air at isothermal conditions.
6. The NC values, sound pressure level, are based on a room absorption of 10 dB re 10-12 watts and one diffuser.
7. Blanks “—” indicate an NC level below 15.
7. The NC values, sound pressure level, are based on a room absorption of 10 dB re 10-12 watts and one diffuser.
8. Blanks “—” indicate an NC level below 15.
Maximum Flow Selection TableInlet Neck Velocity, fpm 400 500 600 700 800 900 1000 1200Size Velocity Pressure 0.010 0.016 0.022 0.031 0.040 0.050 0.062 0.090
6 Static Pressure 0.014 0.021 0.031 0.042 0.054 0.069 0.085 0.123Total Pressure 0.024 0.037 0.053 0.072 0.094 0.119 0.147 0.212CFM 79 98 118 137 157 177 196 236NC — — — 17 21 24 28 33Throw, ft 1-2-4 2-2-5 2-3-6 2-3-6 2-4-7 3-4-7 3-5-8 4-6-8
8 Static Pressure 0.022 0.034 0.049 0.067 0.087 0.110 0.136 0.196Total Pressure 0.032 0.050 0.072 0.097 0.127 0.161 0.199 0.286CFM 140 174 209 244 279 314 349 419NC — — 18 23 27 30 33 39Throw, ft 2-3-7 3-4-7 3-5-8 4-6-9 5-7-9 5-7-10 6-7-11 7-8-12
10 Static Pressure 0.030 0.047 0.068 0.092 0.120 0.152 0.188 0.271Total Pressure 0.040 0.063 0.090 0.123 0.160 0.203 0.250 0.361CFM 218 273 327 382 436 491 545 654NC — 17 23 27 31 35 38 44Throw, ft 4-5-9 4-7-11 5-8-12 6-9-12 7-9-13 8-10-14 9-11-15 9-12-16
12 Static Pressure 0.038 0.060 0.086 0.118 0.154 0.195 0.240 0.346Total Pressure 0.048 0.076 0.109 0.148 0.194 0.245 0.302 0.436CFM 314 393 471 550 628 707 785 942NC — 21 26 31 35 39 42 47Throw, ft 5-8-11 6-9-13 8-10-14 9-11-15 9-11-16 10-12-17 10-13-18 11-14-20
Modulated Flow Selection TablesP tcuD 03.0sP tcuD 02.0sP tcuD 01.0sP tcuD 50.telnI
Size CFM Throw, Ft. NC CFM Throw, Ft. NC CFM Throw, Ft. NC CFM Throw, Ft. NC
6" 111 2-3-6 21 157 3-4-7 29 222 4-6-8 37 272 4-6-9 41
128 2-3-6 24 181 3-4-7 29 256 4-6-9 38 313 5-7-10 44
150 2-4-7 28 213 3-5-8 30 301 5-7-10 40 369 6-7-11 46
8" 144 2-4-7 20 203 3-5-9 28 287 5-7-11 35 352 6-8-12 40
176 3-5-8 24 249 5-7-10 28 352 6-8-12 37 432 8-9-13 43
211 3-5-8 28 299 5-7-10 29 423 7-8-12 39 518 7-9-13 45
10" 179 2-3-7 19 254 3-5-9 27 359 4-7-11 35 440 5-8-12 40
231 5-7-13 25 326 7-10-16 27 461 9-13-19 37 565 11-14-21 43
281 5-7-11 30 398 6-9-13 29 562 9-11-15 39 689 10-12-17 45
12" 217 4-6-12 19 307 6-9-15 27 434 8-12-18 35 532 10-14-20 40
290 5-8-14 26 410 8-11-17 27 579 11-14-20 37 709 13-16-23 43
358 6-9-12 31 507 8-10-14 29 716 10-12-17 39 877 11-13-19 45
PerformanCe data – 24" X 24" modUle
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 85
Relia
ble
Reliable Products
Floor Diffusers 86
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com86
Velocity450 FPM
CFM Throw Spread
10 X 21/4
12 X 21/4
14 X 21/4
8 X 410 X 412 X 414 X 4
8 X 610 X 612 X 614 X 6
L x W L x W L x W
21/4 X 10
21/4 X 12
21/4 X 14
4 X 10
4 X 12
4 X 14
6 X 10
6 X 12
6 X 14
Size
Size Selection Data
Velocity500 FPM
Velocity550 FPM
Velocity600 FPM
Velocity650 FPM
Velocity700 FPM
40
55
65
80
100
110
125
150
170
4.8
5.3
5.5
5.4
5.9
6.5
7.0
7.1
7.3
6.5
7.5
8.5
9.0
9.0
9.5
10.0
11.0
11.0
45
60
70
90
110
125
140
165
190
5.1
5.6
5.8
5.6
6.1
6.7
6.7
7.3
7.5
7.0
9.0
10.5
10.0
10.0
10.0
11.5
12.2
12.0
50
65
75
100
120
135
155
180
210
5.4
6.0
6.3
6.0
6.5
7.0
7.0
7.7
8.4
7.3
9.3
11.0
11.0
11.4
11.8
12.8
12.9
13.0
55
70
85
110
130
150
170
200
230
5.5
6.5
6.7
6.8
7.6
7.6
8.1
9.0
9.3
7.5
9.5
11.3
12.0
13.0
13.0
14.1
14.5
14.3
60
80
90
115
145
160
180
215
245
5.8
6.6
6.8
7.0
7.8
8.0
8.7
9.4
9.8
7.8
10.0
11.2
13.4
13.7
13.8
14.7
15.0
15.5
65
85
100
125
155
175
195
230
265
6.2
6.7
7.0
7.6
8.0
8.6
9.1
9.8
10.3
8.0
10.5
12.4
14.0
14.5
14.5
15.0
16.0
16.5
CFM Throw Spread CFM Throw Spread CFM Throw Spread CFM Throw Spread CFM Throw Spread
Floor Diffusers
PerformanCe data
stoCk sizes
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 87
ACCE
SS D
OORS
Access Doors
Access Doors – Hinged or Double Catch Lock 88
stoCk sizes
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com88
Access Doors –Hinged or Double Catch Lock
COnSTRUCTiOn SPECiFiCATiOnS• frame: 22 ga. Galv steel• door: 24 ga. Galv steel• insulation: 1" thick fiberglass• frame sizes shown are nominal actual opening sizes
are 1-1/4" smaller
roUnd dUCt aCCess doors model dsa-Ga
6 X 6 12 X12 18 X 18
8 X 8 14 X 14 20 X 20
10 X 10 16 X 16 24 X 24
SiZES AVAiLABLE
SPECiFiCATiOnS• formed 20 guage metal plates• Polfoam insulation• steel bolt• steel compression springs• Polypropylene knobs with metal inserts• Closed cell neoprene gasket
nOTES• available in the following materials:
- Galvanized - stainless steel - aluminum Contact factory for availbility of other materials.
• inner plate is 2" smaller in diameter than outer plate.• Bolt length is increased for easy installation.• self adhesive template included for accurate cut-out• reference chart for sizes
model Cad
model Had
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 89
FLEX
IBLE
TEC
H., T
RIAN
GLE
MFG
.
FLEXIBLE TECHNOLOGIES, TRIANGLE MFG.
Flexible Tubing 90
Locking Ties 90
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com90
Flexible Tubing(25 Foot Lengths unless otherwise noted)
Locking Ties
2 3 4 5 6 7 8 9 10 12 14 16 18 20
KM X X X X X X X X Insulated – Low to High Pressure
SLP-10 X X X X X X X X X X Non Insulated – Low to High Pressure
STL X X X Non Insulated – Low to Medium Pressure
Model Max. diameter length
SLT10H 10 35
STLT14H 14 46
KM S-LP-10STL
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 91
Q’M
ark,
Lea
ding
Edg
e &
The
rmos
tats
Q’Mark, Leading Edge & ThermostatsUnit Heaters Type MUH 92
Architectural Heavy-Duty Wall Heaters — Type AWH-4000 94
Commercial Wall Heaters – Fan-Forced — Type CWH-1000 95
Commercial Wall Heaters – Fan-Forced — Type CWH-3000 96
Ceiling Mounted Heaters – Fan-Forced — Type QCH 97
Electric Baseboard Heaters — Type 2500 97
Commercial Downflow Ceiling Mounted Heaters — Type CDF 98
Heat Recovery Ceiling Fans (Leading Edge) 99
Thermostats 101
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com92
APPLiCATiOnSUnit mounts either horizontally or vertically. totally versatile. for fac-tories, warehouses, garages, stores, shipping rooms, power stations, aircraft hangers. Can be used for primary, supplementary, spot, or dual-system heating.
FEATURES• Wide range of optional control kits are field installable, increasing the mUH
adaptability to the specification market.
• forced air unit heater with 10 power ratings; from 3 kW to 50 kW heating output; 208, 240, 277 and 480v, 10,230 to 170,500 BtU/hr.
• 32 compatible models (no need to try to assemble a heating system from 70 or 80 models!)
• Heavy gauge die-formed steel housing. two-toned, smartly styled.
• advanced pull-through air flow design draws air across heating element for more even air distribution and cooler element operation.
• specially designed venturi outlet to meet that added throw as required in vertical position.
• Branch circuit fusing (when required).
• Completely enclosed fan motor.
• 1- or 3-phase wiring on 5 through 10 kW 208/240v and 15 kW 208v units (field interchangeable).
• aluminum-finned, copper clad steel sheath heating element has longer useful life, because of cooler sheath temperature and faster heat dissipa-tion.
• 24v control transformer standard on most models, providing a safer and more accurate means of temperature control. 3 kW and 5 kW, 208-277v, have line voltage controls as standard (24v control available on made-to-order basis).
• automatic reset linear thermal cut-out, capillary type, provides protection over entire length of element areas (manual reset protection available on made-to-order basis).
• 2-speed fan selector switch (25 to 50 kW models).
• fan delay feature eliminates cold drafts. element heats up before fan cuts in, then fan continues to distribute heat after element shuts off.
• ruggedly built, yet lighter weight for easier installation. no piping flues, valves, or traps.
• individually adjustable discharge louvers to control air flow.
• Choice of optional diffusers for variety of air patterns, maximizing heat concentration and coverage in the vertical position.
• meets all Ul, neC, and osHa requirements.
Unit Heaters Type MUH
MOUnTinG LiMiTATiOnSUnit heaters should not be used in potentially explosive atmo-spheres. the finish is not intended for direct salt spray exposure in marine applications or the highly corrosive atmospheres of swim-ming pools, chemical storage bins, etc. do not install unit heaters above recommended maximum mounting height. obstructions must not block unit heater air inlet or discharge. Heaters must be mounted at least 7’ above the floor to prevent accidental contact with the heating element or fan blade which could cause injury.
cAtAlOG nuMBer used On
MMB10 MUH03, 05, 07 & 10
MMB20 MUH15 & 20
MMB30 MUH25 & 30
MMB50 MUH40 & 50
diMensiOn 3 - 20kw 25 - 50kw
A 7¼" 97/16"
B 9½" 143/8"
c 7¼" 121/8"
d 1115/16" 21/16"
e 2¼" 3"
l 20½" 2815/16"
M 915/16" 1415/16"
n 3¼" 4½"
BRACKET SIZE
UNIVERSAL WALL & CEILING BRACKET cAtAlOG nuMBer
heiGht Width dePth
Muh03 & 05 16" 14" 7½"
Muh07 & 10 21¾" 19" 7½"
Muh15 & 20 21¾" 19" 12¾"
Muh25 & 30 30" 265/8" 11¾"
Muh40 & 50 30" 265/8" 171/8"
DIMENSIONS
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 93
Q’M
ark,
Lea
ding
Edg
e &
The
rmos
tats
CATALOGNUMBER
ELECTRICAL DATACONTROLVOLT (1)
2 STAGE ELEMENT CONTROL
AIR DELIVERY DATA FAN MOTOR DATA MOUNTING HEIGHTHORIZ.THROW
WIRE SIZE
WT. (LBS.)
W/BRCKT.
VOLTS PHASE KW MBTU/HR. AMPS (3) CFM (2) FPM (2) ∆T (°F) VOLTS RPM (2) HP HORZ. VERT.
MUH0381 208 1Ø 3 10.2 14.5 208 N/A 350 800 27° 208 1600 1/100 8 9 12 AWG 12 27
MUH0581 208 1-3Ø 5 17 24 208 5A 350 800 45° 208 1600 1/100 8 9 12 AWG 10 27
MUH078 208 1-3Ø 7.5 25.6 36 24 5B 650 970 37° 208 1600 1/30 9 14 18 AWG 6 38
MUH108 208 1-3Ø 10 34.1 48 24 5B 650 970 49° 208 1600 1/30 9 14 18 AWG 4 38
MUH158 208 1-3Ø 15 51.2 72 24 5A 910 1640 52° 208 1530 1/20 11 20 35 AWG 2 53
MUH308 208 3Ø 30 102.3 84 24 5A 2100/1800 2100/2030 45°/53° 208 1600/1375 1/4 12 20 50 AWG 1 93
MUH0321 208/240 1Ø 2.2/3.0 7.5/10.2 11.0/12.5 208/240 N/A 350 800 27° 208/240 1600 1/100 8 9 12 AWG 12 27
MUH0521 208/240 1-3Ø 3.7/5.0 12.6/17.0 18.0/21.0 208/240 5A 350 800 45° 208/240 1600 1/100 8 9 12 AWG 10 27
MUH072 208/240 1-3Ø 5.6/7.5 19.1/25.6 27.0/31.3 24 5B 650 970 37° 208/240 1600 1/30 9 14 18 AWG 8 38
MUH102 208/240 1-3Ø 7.5/10.0 25.6/34.1 36.0/42.0 24 5B 650 970 49° 208/240 1600 1/30 9 14 18 AWG 6 38
MUH152 208/240 3Ø 11.2/15.0 38.2/51.2 31.3/36.1 24 5C 910 1640 52° 208/240 1530 1/20 11 20 35 AWG 6 53
MUH202 208/240 3Ø 15.0/20.0 51.2/68.2 41.2/48.0 24 5C 1320 2060 48° 208/240 1500 1/10 12 23 41 AWG 4 60
MUH252 208/240 3Ø 18.7/25.0 63.8/85.2 52.0/60.0 24 5A 2100/1800 2100/2030 38°/44° 208/240 1600/1375 1/4 13 23 50 AWG 3 93
MUH0371 277 1Ø 3 10.2 11 277 N/A 350 800 27° 277 1600 1/100 8 9 12 AWG 14 27
MUH0571 277 1Ø 5 17 18 277 N/A 350 800 45° 277 1600 1/100 8 9 12 AWG 10 27
MUH0341 480 3Ø 3 10.2 3.6 24 N/A 350 800 27° 480 1600 1/100 8 9 12 AWG 14 27
MUH0541 480 3Ø 5 17 6 24 N/A 350 800 45° 480 1600 1/100 8 9 12 AWG 14 27
MUH074 480 3Ø 7.5 25.6 9 24 5B 650 970 37° 480 1600 1/30 9 14 18 AWG 14 38
MUH104 480 3Ø 10 34.1 12 24 5B 650 970 49° 480 1600 1/30 9 14 18 AWG 14 38
MUH154 480 3Ø 15 51.2 18 24 5C 910 1640 52° 480 1530 1/20 11 20 35 AWG 10 53
MUH204 480 3Ø 20 68.2 24 24 5C 1320 2060 48° 480 1500 1/10 12 23 41 AWG 10 60
MUH254 480 3Ø 25 85.2 30 24 5C 2100/1800 2100/2030 38°/44° 480 1600/1375 1/4 13 23 50 AWG 8 93
MUH304 480 3Ø 30 102.3 36 24 5C 2100/1800 2100/2030 45°/53° 480 1600/1375 1/4 12 20 50 AWG 6 93
MUH404 480 3Ø 40 136.4 48 24 5A 3000/2600 3260/2900 42°/49° 480 1525/1420 1/2 15 28 60 AWG 4 114
Unit Heaters Type MUH
seleCtion CHart - stoCk sizes
oPtional field installed eleCtriCal Controls
NOTES:1 All standard units are supplied with a low voltage control transformer and contactor (24V) except MUH03 & 05, 208, 240 & 277 volt models Low voltage control on these units is available on made to order All units are also available on special order for 120 volt control; internal with transformer or external without transformer 2 On dual voltage units CFM, FPM, & RPM ratings are listed at higher voltage operation in Full Line Catalog 3 On dual phase units maximum amp draw is listed for respective voltage in Full Line Catalog 4 25 thru 50 KW models having two-speed motors and dual CFM ratings are listed in Full Line Catalog 5A Standard5B Optional - made to order - amp load unbalanced on 3 Phase 5C Optional - made to order - amp load balanced on 3 Phase * Must use 2-stage Thermostat on 3Ø operation
CATALOG NO. DESCRIPTION ELECTRICAL RATING USE WITH
MT1Single Pole Internal Thermostat-Temp.Range: 40F - 85F
25A @ 120, 240VAC Res.22A @ 277VAC Res.
All MUH Series Heaters (except MUH0521 3Ø, which use MT2).
MT2Two Stage Internal Thermostat-Temp.Range: 40F - 85F
25A @ 120, 240VAC Res.22A @ 277VAC Res. 125VA
MUH0521 3Ø, MUH0581 3Ø, MUH158, MUH208, MUH252, MUH302, MUH308, MUH402, MUH502, MUH504, MUH508
MHRTHeat Recovery Thermostat with Relay(24V Coil-Single Pole Normally Open) Hi - 120F, Low - 60F
6 AFL, 35 ALR, 250VAC, 60Hz3 AFL, 18 ALR, 480VAC, 60Hz
All MUH Series Heaters (except MUH0321, MUH0371, MUH0381, MUH0521, MUH0571, MUH0581 Units unless optional control transformer is supplied.
MPDS25 Power Disconnect Switch (3 Pole) 25A @ 600VAC, Res.MUH0321, MUH0341, MUH0371, MUH0381, MUH0521, MUH0541, MUH0571, MUH0581, MUH074,MUH104, MUH154, MUH204
MPDS60 Power Disconnect Switch (3 Pole) 63A @ 600VAC, Res.MUH702, MUH077 , MUH078, MUH102, MUH107, MUH108, MUH152, MUH158 3Ø only, MUH202, MUH208, MUH252, MUH254, MUH304, MUH404, MUH504
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com94
Architectural Heavy-Duty Wall Heaters – Fan-ForcedType AWH-4000
APPLiCATiOnSQmark’s high-capacity, heavy-duty fan-forced wall heaters are designed for use almost anywhere in commercial or industrial areas requiring high capacity and quick recovery. they perform exceptionally well in such applications as motels, entryways, stores, public rest rooms, warehouses and other large, hard to heat areas.
FEATURES• 1500, 2000, 3000, 4000, and 4800 watts; 208, 240, 277 volts; 60 hz.
• steel finned metal sheath electric heating elements with low sheath temperatures provide uniform heat and long service life.
• Closely spaced grille bars discourage insertion of foreign objects and direct air downward to effectively distribute heat…keeping floors warm and dry.
• integral thermostat for quick installation… separate thermostat not necessary. (range: 40° - 90°f.) aWH series has tamper resistant thermostat adjustable with a narrow blade screwdriver through the bar grille.
• thermal overheat protector disconnects power in case of over heating due to accidental blockage.
• Built-in double-pole power disconnect switch for added safety dur-ing maintenance.
• Built-in fan delay switch energizes fan motor only after elements are heated…prevents discharge of unheated air. When heat shuts off, de-energizes fan motor after residual heat has been dissipated.
• Can be wired with standard 60°C wire.
• Permanently lubricated totally enclosed fan motor provides long life and low maintenance; gently distributes warmth throughout room area. 100 Cfm.
• Contemporary steel bar grille with durable polyester powder coat finish and satin finished aluminum frame…retains attractive appear-ance through years of use.*
• optional accessory power control relays (24 or 120v holding coil) or pneumatic electric (P/e) switch.
• recess or surface mount in standard 2" x 4" stud walls.
* Northern White color is optional. (Add NW suffix to cat. #).
MOUnTinG LiMiTATiOnS1. for wall mounting - do not install back box closer
than 8 inches from floor or adjacent wall.2. do not install heater behind towel rack, behind
door, in floor, in closet, in ceiling or where air flow may be obstructed.
all controls are concealed behind the front cover making them essentially tamper proof. they will accommodate pneumatic/electric or low-voltage controls commonly used with computerized energy management systems.
CATALOG NUMBER
VOLTS PHASE WATTS AMPS WEIGHTWIRE SIZE
AWH4404* 240/208 14000/30002000/1500
16.7/14.58.3/7.2
25 lbs.25 lbs.
10 AWG& 12 AWG
AWH4407* 277/240 14000/30002000/1500
14.5/12.57.2/6.3
25 lbs.25 lbs.
12 AWG
AWH4307* 277 1 3000/1500 10.8/5.4 25 lbs. 12 AWG
AWH4408* 208 1 4000/2000 19.2/9.6 25 lbs. 10 AWG
AWH4507 277/240 1 4800/3600 15.0/17.3 25 lbs. 10 AWG
*Heaters shipped at higher wattage. Units can be converted to half-wattage in field.
CATALOG NUMBER DESCRIPTION
AWHSM Surface Mounting Frame15-3/8" W x 19-3/16" H x 3-3/4" D
AWHS1 1" Semi-Recess Mounting Frame15-3/8" W x 19-3/16" H x 1" D
AWHS2 2" Semi-Recess Mounting Frame15-3/8" W x 19-3/16" H x 2" D
AWHR2 24V H.C. Time Delay Relay
aCCessories & Controls (oPtional)
seleCtion CHart - stoCk sizes
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 95
Q’M
ark,
Lea
ding
Edg
e &
The
rmos
tats
Commercial Wall Heaters – Fan-ForcedType CWH-1000
APPLiCATiOnSfast heat response, compact design and versatility make the CWH1000 series heaters ideal for dens, basements, con-verted attics and breeze ways, garages, bathrooms, small offices, workshops and similar areas. also, adaptable to mul-tiple installations in somewhat larger or odd shaped rooms.
FEATURES• Heating element is heavy-duty steel fins brazed to steel
sheathed tubular elements in a grid pattern that covers the entire discharge area.
• fan delay: on a call for heat, element is energized but fan is delayed until element is warm, eliminating the circulation of cold air during start up. When the thermostat is satisfied, the element is de-energized, but the fan continues until all heated air is discharged providing longer component life and higher comfort level.
• designed for easy installation. Heater is mounted prior to wiring. Both hands are free to make field connections in roomy compartment.
• motor is totally enclosed, impedance protected with perma-nently lubricated bearings.
• airflow system maximizes air volume at minimum noise level; 65 Cfm.
• rugged louvered commercial grade steel grille creates downflow air pattern.
• this heater is designed for installation in 2 x 4 or larger wall sections using the wall box provided. the heater may also be surface mounted to the wall by using the surface mounting frame, model no. CWHsm (order separately).
• includes built-in disconnect switch.
• the heater may be wired with standard building wire (60°). refer to specification chart for correct supply voltage and wire size.
• Built-in snap action thermostat (no radio/tv interference; 40° -85°f).
• northern White durable polyester powder coat finish.
MOUnTinG LiMiTATiOnS1. do not install heater closer than 4" from floor. 2. do not install heater behind towel rack, behind door, in
floor, in ceiling, in closet, or where air flow may be ob-structed.
3. requires 3 wires if remote thermostat is desired.
CATALOG NUMBER
VOLTS PHASE WATTS AMPS BTU/HRWIRE SIZE
CWH1157DS277240
11500/750*1112/562*
5.5/2.754.7/2.35
5120/25603840/1920
14 AWG
CWH1207DS277240
12000/1000*1500/750*
7.2/3.616.25/3.2
6826/34135120/2560
14 AWG
CWH1208DS 208 1 2000/1000* 9.6/4.8 6826/3413 14 AWG
seleCtion CHart - stoCk sizes
CATALOG NUMBER DESCRIPTION
CWHSM Surface Mounting Frame (Assessory)Order Separately. 12-1/2" H x 10-3/8" W x 4" D
CWHS1 1" Recessed Frame 12-1/2" H x 10-3/8" W x 1" D
aCCessories (oPtional)
Grille: 12½" H x 10-33/8" W x 1" D
Back Box: 11¼" H x 9½" W x 3¾" D
*Factory wired for higher wattage, field convertible to half wattage
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com96
Commercial Wall Heaters – Fan-ForcedType CWH-3000
APPLiCATiOnSfor supplementary heating of offices, reception rooms, game rooms, family rooms and similar light-duty commer-cial and residential applications.
FEATURES• 1500, 2000, 3000, 4000 and 4800 watts; 208, 240, 277
volts; 60 hz. • steel finned metal sheath electric heating elements pro-
vide uniform heat and long service life. • integral thermostat for quick installa tion... separate ther-
mostat not necessary. (range: 40 -90°f.)• fan only operation for summer use. • thermal overheat protector disconnects power in event of
overheating due to accidental blockage.• Built-in power disconnect switch for added safety during
maintenance.• Built-in fan delay switch energizes fan motor only after
elements are heated... prevents discharge of unheated air. When heat shuts off, de-energizes fan motor after residual heat has been dissipated.
• Can be wired with standard 60°C wire. • Permanently lubricated totally enclosed fan motor provides
long life and low maintenance; gently distributes warmth throughout room area. 100 Cfm.
• front cover is finished in northern White durable polyes-ter powder coat finish. a hole plug is provided for tamper resistant installations.
• recess or surface mount in standard 2" x 4" stud walls
CATALOG NUMBER VOLTS PHASE WATTS AMPS SHIP WEIGHT
CWH3150 120 1 1500 12.5 22 lbs.
CWH3180 120 1 1800 15 22 lbs.
CWH3404* 240/208 14000/30002000/1500
16.7/14.58.3/7.2
22 lbs.
CWH3407* 277/240 14000/30002000/1500
14.5/12.57.2/6.3
22 lbs.
CWH3307* 277 1 3000/1500 10.8/5.4 22 lbs.
CWH3408* 208 1 4000/2000 19.2/9.6 22 lbs.
seleCtion CHart - stoCk sizes
CATALOG NUMBER DESCRIPTION Ship Weight.
CWH3SM Surface Mounting Frame 2 lbs.
CWH3S1 1" Semi-Recessed Frame 2 lbs.
aCCessories & Controls (oPtional)
MOUnTinG LiMiTATiOnS1. do not install heater closer than 8" from floor or adjacent
wall surface, behind towl rack or door, upside down or side up, in floor, ceiling or closet
note: factory wired for higher wattage, field convertible to half wattage.
Grille: 193/16" H x 155/16" W x 37/8" D
Back Box: 18¼" H x 14-5/16" W x 37/8" D
*Factory wired for higher wattage, field convertible to half wattage
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 97
Q’M
ark,
Lea
ding
Edg
e &
The
rmos
tats
Ceiling Mounted Heaters – Fan-Forced Type QCHElectric Baseboard Heaters – Type 2500
seleCtion CHart - stoCk sizes
• Ceiling Mounted• Built-in disconnect switch• Three Piece Design• Recessed Installation
or surface mount• Standard Navajo White Finish• 65 CFM
APPLiCATiOnSQCH type fan forced mounted heaters are designed for dens, base-ments, converted attics, breeze ways, garages, bathrooms, small offices, workshops and similar areas Also adaptable to multiple in-stallations in somewhat larger or odd shaped rooms Grille: 10-1/2"L X 12-1/2"W X 1" D Housing: 9-3/4" L x 11" W x 3-3/4" D
CATALOG NUMBER VOLTAGE **WATTAGE AMPS SHIPPING WT.(LBS.)
Qch1101 120 1000500
8 34 7 10
Qch1151 120 1500750
12 56 3 10
Electric Baseboard Heaters–Type 2500
FEATURES• easily installed without disassembly.• lead wires allow quick field connection to either end of
heater.• easy out knockouts at each end for convenient wiring. • Chimney fin element design for maximum air circulation.
airflow is directed away from walls to help prevent wall soiling.
• Ul listed for installation on wall at floor level with wall-to-wall carpeting. Heater stands unsupported during installation.
• navajo White enamel finish retains attractive appearance and is compatible with all interior decors.
• Pre-notched mounting guide marks for fast and easy installation without disassembling the unit.
• Built-in cable clamp in both wiring compartments to restrain incoming cables without using additional hardware.
• Permanently attached copper grounding wire in each wiring compartment.
APPLiCATiOnSfor use in residential construction such as single family homes, apartments, modular or mobile homes as well as commercial, indus-trial and institutional construction. Use as primary, secondary or supplemental heat for new construction or remodel applications.
cAtAlOG nuMBer
VOlts WAtts lGth. shiP Wt. (lBs.)
25426W 240/208 500/376 2’6" 6 3
2543W 240/208 750/564 3’ 7 5
2544W 240/208 1000/752 4’ 10
2545W 240/208 1250/940 5’ 11 5
2546W 240/208 1500/1128 6’ 14
25126W 120 500 2’6" 6 3
2513W 120 750 3’ 7 5
2514W 120 1000 4’ 10
2515W 120 1250 5’ 11 5
2516W 120 1500 6’ 14
seleCtion CHart - stoCk sizes
cAtAlOGnuMBer
descriPtiOn shiP Wt. (lBs.)
TA1AW SP Thermostat, rated 22A @ 120-277V
1 lb
TA2AW DP Thermostat, rated 22A @ 120-277V
1 lb
aCCessories & Controls for Heaters(installs in either Junct Box)
TA1A, TA2A
** As shipped – Field adjustable to 1/2 wattage Note: Requires two separate leads from heater to field supplies single pole wall thermostat
Dimensions: 6 3/4"H x 2 7/8"D Length varies with model See table
CATALOG NUMBER DESCRIPTION Ship Weight.
QCHSM Surface Mount Sleeve 2 lbs.
aCCessories
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com98
Commercial Downflow Ceiling Mounted HeatersType CDF
Type CDF-RE enclosures also mount easily into standard 2 x 2 ceiling grids
In the ceiling. . . or on it!
Type CDF ceiling-mounted fan-forced heaters are designed for commer-cial and industrial areas requiring electric fan-forced heat Capacities are 2,000 to 5,000 watts Type CDF-SE surface enclosures are designed to mount flat on the ceiling and extend only six inches into the room Type CDF-RE enclosures have no protrusions outside the recess box, allow-ing the heater to recess only seven inches into ceiling space Mounts into permanent ceiling with trim ring
BUILT-IN FAN DELAY — Space temperature is controlled by a wall or unit-mounted thermostat When the thermostat calls for heat, the heating elements and fan energize When the thermostat is satisfied, the ele-ments shut off, but the fan continues to operate until all of the heated air is discharged This feature avoids exposing the heater to residual heat, thus achieving a high comfort level and longer component life
AUTOMATIC THERMAL CUTOUT — A thermal cutout shuts off the heater in the event of over-heating and reactivates the heater when the temperature returns to normal
MULTIPLE PHASE HEATERS — The 208 and 240 volt heaters can be field converted from single to three-phase operation 277 volt single-phase heater is also available
MULTIPLE WATTAGE HEATER SECTIONS — The 5,000 watt heater can be field converted to 3,800 watts or 2,500 watts, and the
4,000 watt heater is convertible to 3,000 or 2,000 watts
THUMB PINS align and temporarily hold the enclosure cover to the heating section freeing both hands to finish installation
300 CFM of airflow
Phosphatized, Baked Enamel Finish: All sheet metal and extruded aluminum parts, except the back box, are phosphatized, then finished by a baked enamel electrostatic painting process.
Elements: Steel fins are cop-per-brazed to low-watt density, steel-sheathed, tubular heating elements which are arranged in a uniform grid pattern. The grid
covers the entire intake area, resulting in uniform
heating of all discharged
air.Efficient Operation: The five-bladed aluminum fan and the rugged impedance-protected, totally-en-closed motor, achieve efficient operation.
CATALOG NUMBER DESCRIPTION KW(1) BTU/HR. (000) VOLTS AMPS PHASE(2) SHIPPING WT.
CDF542
HeaterSection
Only
4/3/02 13.7/10.2/6.8 240 16.7/12.5/8.3 1-3 27 lbs.
CDF558 5/3.8/2.5 17.1/13.0/8.5 208 24.0/18.3/12.0 1-3 27 lbs.
CDF552 5/3.8/2.5 17.1/13.0/8.5 240 20.8/15.8/10.4 1-3 27 lbs.
CDF557 5/3.8/2.5 17.1/13.0/8.5 277 18.1/13.7/9.0 1 27 lbs.
Cdf aCCessoriesCATALOG NUMBER DESCRIPTION
SHIPPING WT.
CDFSE Surface Mounting Enclosure Only - To Be Used With Above Heater Section. Dim. 20"L x 16 1/2"W x 5 3/4"D. 10 lbs.
CDFRE Recess Mounting Enclosure Only - To Be Used With Above Heater Sections. Dim. 23 3/4"L x 23 3/4W x 7"D. 18 lbs.
CDFT Thermostat SPST Range 45 to 95˚F. 1 lb.
CDFDS Power Disconnect Switch (3-Pole) 30 amps, 600 volts, 1Ø, 60 Hz. 1 lb.
CDFTK Trim Ring for mounting on permanent ceiling (can not be factory installed). 1 lb.
CDFTR4 208/240V Primary Transformer/24V sec. And 24V holding coil control relay. 1 lb.
CDFTR7 277V Primary Transformer/24V sec. And 24V holding coil control relay. 1 lb.
seleCtion CHart - stoCk sizes
(1) Factory wired for highest wattage, field convertible to lower wattages.
(2) Factory wired 1Ø, field convertible to 3Ø.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 99
Q’M
ark,
Lea
ding
Edg
e &
The
rmos
tats
Heat Recovery Ceiling Fans
DUAL PURPOSE
ENERGYCONSERVATION SYSTEM
THE
HEAT-DROPPER®
CONCEPT AND HOW IT WORKSWINTER-Recovers wasted heat by eliminating heat stratification.Trappedwarm air at the ceiling caused by natural heat rise and poor air circulationis equalized by the movement of the massive blade span. Thus ceiling tofloor temperature is equalized.With a heat cost savings of 30k percent, theLEADING EDGE fan system can pay for itself in one year.The eliminationof cold spots increases employee productivity and comfort.
SUMMER-General air recirculation in non air-conditioned buildingscreates a cooling breeze and a “Wind Chill Factor” providing evaporationcooling of the skin surface dropping skin temperature by 6 degrees. TheLEADING EDGE fan system supplements air-conditioned buildings byallowing the thermostat settings to be 8 degrees higher. You’ll feel thecoolness of 72 degrees with the thermostat set on 80 degrees - anincomparable energy savings. Additional advantages, eliminates mold andmildew caused by stagnant air, perfect for high humidity areas. No otherfan has our higher air velocity capabilities. Small fans do not developsufficient CFM to be effective in warm weather.
ENTRAINMENT
(CE
NT
ER
LIN
E)
Only Leading Edge provides university documented performance data.Compare this exclusive data to any other fan available.
COMMERCIALMODELS
56001LC / 56" 120V
56001LC / 56" 120V
56001LC / 56" 120V
INDUSTRIAL &SPECIAL APPLICATIONMODELS
56001 / 56" 120V56007/ 56" 277V
56001 / 56" 120V56007/ 56" 277V
56001 / 56" 120V56007/ 56" 277V
56001 / 56" 120V56007/ 56" 277V
5000
4500
4000
3500
3000
2500
2000
1500
1000
500
7'1"
10'
20'
MO
UN
TIN
GH
EIG
HT
S
TOTAL SQUARE FOOT AREA COVERAGE
5000
4500
4000
3500
3000
2500
2000
1500
1000
500
20'
30'
40'
45'
MO
UN
TIN
GH
EIG
HT
S
AREA COVERAGE SUMMARY BY FAN BY HEIGHT
®
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com100
Heat Recovery Ceiling Fans
Suitable for low
ceiling applications.
U.L. 507 listed.
UL 507 states Ceiling Fans suspended from 7 feet to less than 10 feet (blade height to floor) must have minimum thickness of edge of blade 3/16"
U.S. PATENT# 5,645,403
Provides Superior Air Velocity and Efficiency, The Ideal School Classroom Fans56001LC • 56" Commercial / School Classroom FanDesigned for spacious areas with low ceilings where larger blade diameter span creates maxi-mum air velocity and area coverage at lower RPM’s. Engineered specifically for continuous commercial use with the same manufacturing criteria as our heavy duty industrial line. Ideally suited for classrooms.
Note: Supplied with 24" downrods. Secondary mounting cable supplied.† Effective amount of air volume moved past a plane 20ft. from fan, industry test. All specifications subject to change and improvement.†† Area coverage rated for heat destratification at 20’ blade mounting height.
Maximum continuous operation ambient temperature 105°F
U.S. PATENT# 5,575,624
Maximum Area Coverage at Lowest Total Installed Cost.56001 / 56007 56" Industrial FansEngineered and designed for spacious applications where maximum area coverage is required.
Designed for both winter heat destratification and sum-mertime cooling.
Designed for general applications for above average area coverage and cooling velocity. Ideally suited for factories, gymnasiums, high bay storage facilities.
Powerful, heavy-duty motor for mounting heights to 45 feet.
Note: Supplied with 8" and 24" downrods Secondary mounting cable supplied † Effective amount of air volume moved past a plane 20ft from fan All specifications subject to change and improvement †† Area coverage rated for heat destratification at 20’ blade mounting height Maximum continuous operation ambient temperature 105°F
Blade size Order number Volt Max cfm† area coverage†† shipping Weight
56" 56001lc 120 25,500 3,025 sq ft 24 lbs
Blade size Order number Volt Max cfm† area coverage†† color shipping Weight
56" 56001 120 27,500 3,800 sq ft White 24 lbs
56" 56007 277 26,000 3,800 sq ft White 24 lbs
seleCtion CHart - stoCk sizes
seleCtion CHart - stoCk sizes
Order number item shipping Weight
28001FAN GUARD 62" DIAMETER FOR INDUSTRIAL 56" AND 60" FANS
50 lbs
CeilinG fans aCCessories
Custom models available Consult with factory for information and specifications Use only with heavy-duty / industrial models - Not recommended for low ceiling applications
ceiling Fan GuardFor gymnasiums and public facilities ®
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 101
Q’M
ark,
Lea
ding
Edg
e &
The
rmos
tats
Thermostats
Honeywell
Q-Mark
T651A Light Duty LIne Voltage – 8 Amps
T822D 24 Volt – Positive Office Vertical Stat
T874F 2 Stage – 24 Volt
T87F Round – 24 Volt
T100 Line Volt – Single Pole
T200 Line Volt – Double Pole
WR-80 Heavy Duty Line Voltage
WR-1E30S Pilot Duty Only
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com102
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 103
Mis
cella
neou
s
MiscellaneousSupplies and Products
Vibration Isolators 104
Motors 105
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com104
12 X 12 Cork Rib Pads 18 X 18 Neoprene Pads
Base Mount (Rubber in Shear)
RD1 Black
RD1 Red
RD1 Green
45
70
120
.40
.40
.40
3-1/8"
3-1/8"
3-1/8"
1-3/4"
1-3/4"
1-3/4"
1"
1"
1"
2-3/4"
2-3/4"
2-3/8"
3/16"
3/16"
3/16"
1-1/4"
1-1/4"
1-1/4"
5/16"
5/16"
5/16"
RD2 Black 170 .50 3-7/8" 2-3/8" 1-1/4" 3" 7/32" 1-3/4" 3/8"
RD2 Red
RD2 Green
240
380
.50
.50
3-7/8"
3-7/8"
2-3/8"
2-3/8"
1-1/4"
1-1/4"
3"
3"
7/32"
7/32"
1-3/4"
1-3/4"
3/8"
3/8"
Type LoadLbs. DEFL L W H Bolt
Center T D TappedHole
Hanger Type (Rubber in Shear)
RHD1 Black
RHD1 Red
RHD1 Green
RHD2 Black
RHD2 Green
45
75
120
170
380
.40
.40
.40
.50
.50
3/8"
3/8"
3/8"
5/8"
5/8"
3"
3"
3"
4-1/2"
4-1/2"
2-1/4"
2-1/4"
2-1/4"
3"
3"
2"
2"
2"
2-1/4"
2-1/4"
1-3/8"
1-3/8"
1-3/8"
1-7/8"
1-7/8"
Type LoadLbs. DEFL MRD H W D MH
Base Mount (Spring Loaded)
AS-11
AS-12
AS-13
AS-14
60
100
165
260
1.3
1.3
1.2
1.0
4-1/4"
4-1/2"
4-1/2"
4-1/2"
2-1/4"
2-1/2"
2-1/2"
2-1/2"
3-3/4"
3-3/4"
3-3/4"
3-3/4"
3-1/2"
3-1/2"
3-1/2"
3-1/2"
7/16"
7/16"
7/16"
7/16"
Type LoadLbs. DEFL L W H Bolt
CentersBoltSolts
Hanger Type (Spring Loaded)
SHS-7
SHS-11
SHS-12
SHS-13
SHS-14
35
60
100
165
260
1.5
1.3
1.3
1.2
1.0
1/2"
1/2"
1/2"
1/2"
1/2"
4-1/2"
5-1/2"
5-1/2"
5-1/2"
5-1/2"
2-3/4"
3"
3"
3"
3"
2-1/4"
2-1/4"
2-1/4"
2-1/4"
2-1/4"
2-7/8"
3-7/8"
3-7/8"
3-7/8"
3-7/8"
Type LoadLbs. DEFL MRD H A B MH
Rods by Others
1/2" MAX. ROD
STEEL WASHER
RESILIENT WASHERH
M
3/8" CAP SCREW
WASHER
EQUIPMENT BASE
ADJ. BOLT
2 O.D. SPRING
ACOUSTICAL NON-SKIDNEOPRENE PAD
3 -3/4FREE WT.
1/2
Vibration Isolators
A x B
MRD
L x W
3 - 3/4FREE HT
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 105
Mis
cella
neou
s
Motors
RPM
Motors
Motors – 1 Phase/60 HertzOpen Drip Proof – Ball Bearing
1/6
1/3
1/4
1/3
1/2
1/2
3/4
1
1-1/2
1/4
1/3
1/2
3/4
1
115
115
115
115
115
115/230
115/230
115/230
115/230
115
115
115
115
115
1140
1140
1725
1725
1725
1725
1725
1725
1725
1725/1140
1725/1140
1725/1140
1725/1140
1725/1140
48
56
48
48
56
56
56
56
56
48
56
56
56
56
HP Voltage RPM Frame
Totally Enclosed – Ball Bearing
1/4
1/3
1/2
3/4
1
115
115
115/230
115/230
115/230
1725
1725
1725
1725
1725
48
56
56
56
56
HP Voltage RPM Frame
Motors – 3 Phase/60 HertzOpen Drip Proof – Ball Bearing
1/4
1/3
1/2
1
1-1/2
1-1/2
2
2
3
3
5
5
208-230/460
208-230/460
208-230/460
208-230/460
200
230/460
200
230/460
200
230/460
200
230/460
1725
1725
1725
1725
1750
1750
1750
1750
1750
1750
1750
1750
48
56
56
56
145T
145T
145T
145T
182T
182T
184T
184T
HP Voltage Frame
Explosion Proof – Ball Bearing
1/4 115 1750 48
HP Voltage RPM Frame
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com106
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 107
Youn
g R
egul
ator
s
Young Regulators
Dampers and Controls 108
Remote Cable Controls 108
Socket Wrench 108
Casing and Wire 108
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com108
Casing & WireAPPLiCATiOnSruns between damper and remote contoller. features .054" stainless steel torsion-straightened wire with 3/16" flexible galvanized coil spring casing.
cAtAlOG nuMBer lGth.
BOWden-cW-6 6
BOWden-cW-8 8
BOWden-cW-50 50
Socket WrenchAPPLiCATiOnSfor use with worm gear regulators and Bowden cable controls
cAtAlOG nuMBer lGth.
030-12-sOcket 12"
Remote Cable Controls
Dampers and controls
APPLiCATiOnSfor use with worm gear regulators and Bowden cable controls
Series 270-275 Series 270-301 Series 270-896
cAtAlOG nuMBer
diameter (inches)
5020cc 6
5020cc 8
5020cc 10
5020cc 12
5020cc 14
seleCtion CHart
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 109
Ceru
s In
dust
rial
cAtAlOG nuMBer
diameter (inches)
5020cc 6
5020cc 8
5020cc 10
5020cc 12
5020cc 14
Cerus Industrial
Motor Starters – Models BAS/BAS-1P 110
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com110
Motor Starters - Model BAS
STAnDARD BAS STARTER FEATURES:• Hoa keypad with led status Pilot
lights• voltage & dry Contact inputs for auto
run Command• fireman’s override• damper Control * 1 amp max• Wide range Class 1-30 electronic
overload• flexible Control transformer (CPt)• High reliability Contactors for long life• Combination versions include
disconnect
APPLiCATiOnS:• Ul type 1 for indoor use• locakable cover prevents unauthorized access/
tampering• standard conduit knock-outs top and bottom for easy
installation
Combination Versions include Disconnect:• motor circuit protection disconnect provides branch
and short circuit protection • High interrupting ratings for maximum electrical
systems compatibility • no fuses required - save time and money • locakable handle for safety
STAnDARD SinGLE PHASE STARTER FEATURES• motor circuit protection disconnect provides
branch and short circuit protection • High interrupting ratings for maximum
electrical systems compatibility • no fuses required - save time and money • locakable handle for safety
BaS-1P10 Building Automatic10, 110~240VAC, 0.1–HPHOA, Status, Lockable DisconnectAdjustable Wide Range Overload
BAS-1P
single Phase hP three Phase hP nema size
Base part # Options120V 230V 208V 230V 460V
- 1 1 2 3 00 BAS1-9/J-5 24 Volt Damper Output
- 1 1 2 3 00 BAS1-9/J-5-120 120 Volt Damper Output
5-1 5 2-3 3-5 3-5 3-10 0 BAS1-18/J-22 24 Volt Damper Output
5-1 5 2-3 3-5 3-5 3-10 0 BAS1-18/J-22-120 120 Volt Damper Output
single Phase hP three Phase hP nema size
Base part # Options120V 230V 208V 230V 460V
1/6 5 5 75 - 1 00 BAS1-9/J-G2 5-5 24 Volt Damper Output
1/6 5 5 75 - 1 00 BAS1-9/J-G2 5-5-120 120 Volt Damper Output
1/6 1/3 75 1 5 - 2 2 00 BAS1-9/J-G4-5 24 Volt Damper Output
1/6 1/3 75 1 5 - 2 2 00 BAS1-9/J-G4-5-120 120 Volt Damper Output
1/4 1/2 1 1 3 00 BAS1-9/J-G6-5 24 Volt Damper Output
1/4 1/2 1 1 3 00 BAS1-9/J-G6-5-120 120 Volt Damper Output
1/2 1 1 5 - 2 1 5 - 2 5 0 BAS1-18/J-G8-22 24 Volt Damper Output
1/2 1 1 5 - 2 1 5 - 2 5 0 BAS1-18/J-G8-22-120 120 Volt Damper Output
single Phase hPBase part #
120V 230V
1 - 1 1 - 1 BAS1-P
maGnetiC H-o-a starters - eleCtroniC overload - nema 1 enClosUre
ComBination maGnetiC H-o-a starter - disConneCt - eleCtroniC overload - nema 1 enClosUre
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 111
Puro
lato
r
Purolator
hi-E 40™ Pleated Filter 112
Defiant® Mark 80D™ Pleat 113
single Phase hPBase part #
120V 230V
1 - 1 1 - 1 BAS1-P
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com112
hi-E 40™ Pleated Filter
introductionPurolator’s hi-E 40 filters are medium efficiency, self-supported, extended surface, pleated air filters
Effective in stand-alone applications or as a pre-filter in place of a disposable, permanent, or media pad/frame filter
Easy to install in new or existing side-access housings, package air handling units, and built-up filter banks
Average efficiency: 25-30%
Average arrestance: 90-93%
MERV7 @ 492 FPM
media and supportMedia: Lofted, non-woven pleated filter media composed of non-dyed cotton and synthetic fibers
Media support: Continuously bonded to a corrosion resistant, expanded metal grid allowing a 96% open face area
Pleat configuration: Formed into aerodynamic, semi-tapered, wedge-shaped pleats expanding its capability to capture con-taminants
Options: High Temperature and Class 1 media available Contact factory for pricing and size information
Available treated with an EPA approved bound antimicrobial agent
suggested Product specifications1 The filter shall be the hi-E 40 as manufactured by Purolator Air
Filtration
2 Air filters shall be (1"), (2"), and (4") deep, medium efficiency, pleated media, disposable panel type
3 The filter media shall be self-extinguishing lofted non-woven, non-dyed, natural cotton and synthetic fibers
4 The filter media shall be bonded to a corrosion resistant, ex-panded metal support grid with a 96% open face area
5 To assure no dirty air bypass, the media grid assembly shall be bonded to all interior surfaces of the frame with solvent-free water based glue
6 The support grid shall be formed into a wedge configuration to optimize use of the filter media
7 To maintain accurate pleat alignment on 4" depth filters, die -cut diagonal frame members shall be bonded to the media pack upstream and downstream
Construction featuresFrame: A moisture-resistant die-cut frame
Assembly: A fully bonded double wall frame combines with the integral corner flaps and forms a rugged, durable filter which will not rack, warp or leak under normal operating conditions To assure no dirty air bypass, the media pack is securely bonded to the periphery of the enclosure frame with solvent-free water based glue
U L Classification: Class 2 approved and listed
Tested in accordance with UL Standard 900 and ASHRAE 52 1 1992 and ASHRAE 52 2
In 4" models, accurate pleat alignment is maintained by die-cut pleat spacers on the upstream side
Recommended operating temperature: < 200°F
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 113
Puro
lato
r
Defiant® Mark 80-D™ Pleat
introductionThe Purolator® DEFIANT ®MARK 80-D™ filters are medium efficiency, self-supported, extended surface, pleated air filters Specifically manufactured for system applications requiring high efficiency, non-shedding media filtration Outperforms similar products with respect to initial efficiency and average efficiency, providing optimum filter service life Effective in single filter ap-plications or as improved pre-filter substitutes for disposables, permanent metal filters or media pad/frame filters Industry ap-plications: Pre-filtration for hospitals, health care facilities, food processing plants, telecommunications, pharmaceutical and semi-conductor manufacturing, etc
Based on ASHRAE Standard 52 1-1992:
Average efficiency: 45-50%
Average arrestance: 90-93%
Based on ASHRAE Test Standard 52 2:
MERV 8 (Minimum Efficiency Reporting Value)
media and supportMedia: Synthetic media made up of continuous hydrophobic fibers that do not absorb moisture, and can withstand turbulent, high velocity conditions
Fibers are thermally bonded to eliminate the need for chemical binders that could promote microbial growth or generate VOCs
Improved overall particle size efficiency due to continuous fiber structure and dual stage electrostatic enhancement that captures an increased amount of smaller particulate than conventional media
Media support: Continuously bonded to a corrosion resistant, expanded metal grid allowing a 96% open face area
Pleat configuration: Formed into aerodynamic, semi-tapered, wedge-shaped pleats expanding its capability to capture con-taminants
Frame: Enclosed in a two-piece, high wet-strength beverage board frame
Assembly: A fully bonded double wall frame combines with the integral corner flaps and forms a rugged, durable filter which will not rack, warp or leak under normal operating conditions
To assure no dirty air bypass, the media pack is securely bonded to the periphery of the enclosure frame with solvent-free water based glue
U L Classification: Class 2 approved and listed Tested in accor-dance with U L Standard 900
In 4" models, accurate pleat alignment is maintained with die-cut pleat spacers on the upstream side
Recommended operating temperature: < 200˚F
suggested Product specifications1 The filter shall be the DEFIANT®MARK 80-D™ as manufac-
tured by Purolator Air Filtration
2 Air filters shall be (1"), (2") and (4") deep, medium efficiency, pleated media, disposable panel type
3 The filter media shall be synthetic DEFIANT® filtration media as brand named to Purolator Air Filtration
4 The filter media shall be bonded to a corrosion-resistant, ex-panded metal support grid with a 96% open face area
5 To assure no dirty air bypass, the media grid assembly shall be bonded to all interior surfaces of the frame with solvent-free water based glue
6 The support gird shall be formed into a wedge configuration to optimize use of the filter media
7 To maintain accurate pleat alignment, die-cut diagonal frame members shall be bonded to the media pack upstream and downstream
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com114
hi-E 40 Filters / Defiant Mark 80-D - Stock Sizes
PerformanCe data: defiant® mark 80-d™
seriesnominal (1)
sizeWxhxd
Actual sizeWxhxd
Mark 80-dModel
number
cFM (2)capacity
resist.in. W.G.
sq. ft.
Media area/sq.
ft.face areamed high Final (3)med high
116 pleatsper lineal
foot offace area
12x24x1 11-3⁄8x23-3⁄8x3⁄4 DMK80-2401 600 1000 14 34 1 00 4 3 2 3
16x20x1 15-1⁄2x19-1⁄2x3⁄4 DMK80-6001 665 1100 14 34 1 00 5 0 2 3
16x25x1 15-1⁄2x24-1⁄2x3⁄4 DMK80-6501 850 1400 14 34 1 00 6 3 2 3
18x24x1 17-3⁄8x23-3⁄8x3⁄4 DMK80-8401 900 1500 14 34 1 00 6 5 2 3
20x20x1 19-1⁄2x19-1⁄2x3⁄4 DMK80-0001 850 1400 14 34 1 00 6 2 2 3
20x24x1 19-3⁄8x23-3⁄8x3⁄4 DMK80-0401 1000 1665 14 34 1 00 7 4 2 3
20x25x1 19-1⁄2x24-1⁄2x3⁄4 DMK80-0501 1050 1750 14 34 1 00 7 7 2 3
24x24x1 23-3⁄8x23-3⁄8x3⁄4 DMK80-4401 1200 2000 14 34 1 00 8 8 2 3
215 pleatsper lineal
foot offace area
12x24x2 11-3⁄8x23-3⁄8x1-3⁄4 DMK80-2402 600 1000 12 26 1 00 8 5 4 6
16x20x2 15-1⁄2x19-1⁄2x1-3⁄4 DMK80-6002 665 1100 12 26 1 00 9 6 4 6
16x25x2 15-1⁄2x24-1⁄2x1-3⁄4 DMK80-6502 850 1400 12 26 1 00 12 1 4 6
18x24x2 17-3⁄8x23-3⁄8x1-3⁄4 DMK80-8402 900 1500 12 26 1 00 13 4 4 6
24x24x2 23-3⁄8x23-3⁄8x1-3⁄4 DMK80-4402 1200 2000 12 26 1 00 17 6 4 6
411 pleatsper lineal
foot offace area
12x24x4 11-3⁄8x23-3⁄8x3-3⁄4 DMK80-2404 1000 1250 19 29 1 00 14 0 7 0
20x25x4 19-3⁄8x24-3⁄8x3-3⁄4 DMK80-0504 1750 2170 19 29 1 00 24 0 7 0
24x24x4 23-3⁄8x23-3⁄8x3-3⁄4 DMK80-4404 2000 2500 19 29 1 00 28 0 7 0
seriesnominal (1)
sizeWxhxd
Actual sizeWxhxd
hi-e40Model
number
cFM (2)capacity
resist.in. W.G.
sq. ft.
Media area/sq.
ft.face areamed high Final (3)med high
116 pleatsper lineal
foot offace area
12x24x1 11-3⁄8x23-3⁄8x3⁄4 HE40-2401 600 1000 24 42 1 00 3 1 1 6
16x20x1 15-1⁄2x19-1⁄2x3⁄4 HE40-6001 665 1100 24 42 1 00 3 3 1 6
16x25x1 15-1⁄2x24-1⁄2x3⁄4 HE40-6501 850 1400 24 42 1 00 4 2 1 6
18x24x1 17-3⁄8x23-3⁄8x3⁄4 HE40-8401 900 1500 24 42 1 00 4 5 1 6
20x20x1 19-1⁄2x19-1⁄2x3⁄4 HE40-0001 850 1400 24 42 1 00 4 3 1 6
20x24x1 19-3⁄8x23-3⁄8x3⁄4 HE40-0401 1000 1665 24 42 1 00 5 1 1 6
20x25x1 19-1⁄2x24-1⁄2x3⁄4 HE40-0501 1050 1750 24 42 1 00 5 4 1 6
24x24x1 23-3⁄8x23-3⁄8x3⁄4 HE40-4401 1200 2000 24 42 1 00 6 0 1 6
215 pleatsper lineal
foot offace area
12x24x2 11-3⁄8x23-3⁄8x1-3⁄4 HE40-2402 600 1000 16 24 1 00 6 1 3 1
16x20x2 15-1⁄2x19-1⁄2x1-3⁄4 HE40-6002 665 1100 16 24 1 00 6 6 3 1
16x25x2 15-1⁄2x24-1⁄2x1-3⁄4 HE40-6502 850 1400 16 24 1 00 8 3 3 1
18x24x2 17-3⁄8x23-3⁄8x1-3⁄4 HE40-8402 900 1500 16 24 1 00 9 1 3 1
20x20x2 19-1⁄2x19-1⁄2x1-3⁄4 HE40-0002 850 1400 16 24 1 00 8 1 3 1
20x24x2 19-3⁄8x23-3⁄8x1-3⁄4 HE40-0402 1000 1665 16 24 1 00 9 7 3 1
20x25x2 19-1⁄2x24-1⁄2x1-3⁄4 HE40-0502 1050 1750 16 24 1 00 10 2 3 1
24x24x2 23-3⁄8x23-3⁄8x1-3⁄4 HE40-4402 1200 2000 16 24 1 00 11 6 3 1
411 pleatsper lineal
foot offace area
12x24x4 11-3⁄8x23-3⁄8x3-3⁄4 HE40-2404 1000 1250 20 28 1 00 11 5 5 8
20x25x4 19-3⁄8x24-3⁄8x3-3⁄4 HE40-0504 1750 2170 20 28 1 00 20 0 5 8
24x24x4 23-3⁄8x23-3⁄8x3-3⁄4 HE40-4404 2000 2500 20 28 1 00 23 0 5 8
(1) Width and height dimensions are interchangeable The DEFIANT®MARK 80-D™ and the hi-E 40™ may be installed with pleats running vertical or horizontal (2) Capacity ratings are recommended levels Resistance to airflow data is based on ASHRAE 52 1-1992 Test Method Performance tolerances conform to Section 7 4 of
ARI Standard 850 93 (3) The recommended final operating resistance is typical of systems currently in operation The DEFIANT®MARK 80-D™ and the hi-E 40™ can be operated to higher or
lower final resistance levels without adversely affecting filter efficiency
PerformanCe data: Hi-e 40™
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com 115
PerformanCe data: Hi-e 40™
Notes
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
(847) 437-9690 (309) 691-5160 Elk Grove Village, IL Peoria, IL
www.bruckerco.com116
Notes
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
Manufacturers Representatives ofEngineered HVAC Systems and Equipment
BRUCKER VISIONTo be the customer’s preferred HVAC Manufacturer’s Representative in the Chicago, NW Indiana and Central Illinois markets with top market share positions of our core manufacturers.
CORPORATE STRUCTUREBrucker approaches the HVAC Manufacturer’s Representative market in a dramatically different way in that we are organized into four distinct divisions:
* Engineering Sales * Contractor Sales * Aftermarket Sales * Field Service
Each division within Brucker consists of a dedicated sales and inside support group trained to provide technical product information required to meet our customer’s needs while maintaining the highest levels of service and support.
ENGINEERING SALESBrucker’s Engineering division consists of application sales engineers who focus on our customer’s air movement, air control and air distribution product needs by assisting the professional consulting and mechanical engineers during the design stage of a project. With their technical experience, Brucker’s Engineering staff can provide innovative solutions to meet your air movement specification requirements.
CONTRACTOR SALESBrucker’s Contractor sales staff focuses on meeting the air movement, air control and air distribution needs of our mechanical piping and ventilation contractors. By providing their design build expertise along with high quality service, Brucker’s Contractor sales staff insures a seamless transfer of the project from the design stage to construction phase.
AFTERMARKET SALESBrucker’s Aftermarket Sales group focuses primarily on the filtration needs of building owners and property managers in the commercial, institutional and industrial markets. While the need to provide a healthy indoor environment has become increasingly important, Brucker’s Aftermarket Sales staff can provide solutions to meet indoor air quality specifications through their offering of high-quality filtration products.
FIELD SERVICEBrucker’s Field Service division is comprised of highly experienced technicians that offer check, test, and start-up and support of our products to our customers. Managed by our service coordinator in order to deliver efficient response time, these technicians also possess the training to instruct customers as to the proper use and maintenance of their equipment to ensure a longer service life.
Brucker Company is an HVAC Manufacturer’s Representative in the Midwest that serves the following industries within the Chicago, Central Illinois and Northwest Indiana markets: Mechanical & Ventilation Contractors, Mechanical Engineering Firms, Design Build Contractors, Construction Managers, Service Contractors, Building Managers, and Involved Owners.
Brucker provides engineered solutions to meet your application and specification needs through their comprehensive product offering of high-quality equipment and filtration products. By packaging product with professionalism in the areas of sales and service, Brucker provides exceptional support unparalleled to that of other rep firms.
Brucker Company was founded in 1875. Established as a foundry manufacturer producing steel furnace grates, Brucker diversified, evolved, and engaged in various businesses through the early and mid 1900’s. The development of air conditioning in the United States brought many opportunities to Chicago’s entrepreneurial-based business community, and Brucker Company staked its claim accordingly as an HVAC sales representative and distribution organization.
Brucker has two offices serving the Midwest and over 50 total employees. The company’s corporate headquarters in Elk Grove Village, IL boasts a 30,000 square foot warehouse and distribution facility featuring air distribution and filtration products stocked to meet our customer’s immediate requirements.
Manufacturers Representatives ofEngineered HVAC Systems and Equipment