Brandgennemføringer
description
Transcript of Brandgennemføringer
![Page 1: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/1.jpg)
Energy efficiency
Innovations 2010.
Sound insulation Fire protection
![Page 2: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/2.jpg)
Innovations 2010.
Fire protection:• Portal with all applications
• Action Centre to explain the new products for expert guidance and training
![Page 3: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/3.jpg)
Innovations 2010.
Fire protection
![Page 4: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/4.jpg)
General clause in its currently valid form: „Buildings must be constructed in such a way that fires and smoke are prevented from starting and spreading. In the event of a fire the construction of the building must also enable effective fire-fighting and fire-extinguishing prcedures and enable humans and animals to be rescued.“
Basic principles of building supervision.
![Page 5: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/5.jpg)
• Model building regulation (MBO)• State building regulations (LBO)
• Technical building regulations and norms:• DIN EN 1363, DIN EN 1364, DIN 4102• MLAR, LAR, RbALei• Supplementary regulations (z. B. KhBauVO,
MVStättV, MvkVO, MschulbauR, MidBauRL)
Basic principles of building supervision.
![Page 6: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/6.jpg)
Basic principles of building supervision.
Building Class 1• free-standing
building.. • bis zu 7 m Höup to
7 m high• Maximum of 1
housing unit (max. 400 m2).
and • free-standing
building used for agricultural forestry purposes
Building Class 2• up to 7 m high.• maximum of two
hosing unites (total of max. 400 m2).
Building Class 3• other buildings.• up to 7 m high.• minimum of three
housing units.
Building Class 4• up to 13 m high
Building Class 5• other buildings
including unterground buildings.
WE = WohneinheitOKF = Oberkante Fußboden
![Page 7: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/7.jpg)
• Minimum preriod in minutes in which a component exposed to fire must not exceed a mean temperature rise of 140 K (max. 180 K in places) on the side not exposed to the fire.
• Classes: 30 / 60 / 90 / 120 / 180 mins.
Basic principles. Fire resistance class.
![Page 8: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/8.jpg)
• Minimum period in minutes in which a component exposed to fire must not exceed a mean temperature rise of 140K (max. 180 K in places) on the side not exposed to the fire.
• Classes: 30 / 60 / 90 / 120 / 180 mins.
Temperature increase of 140 KAmbient temperature before the fire: 22 °C
< 162 °C
Basic principles. Fire resistance period.
![Page 9: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/9.jpg)
Example of definitions: (walls, ceilings, pillars)
F30-A fire-retardant/non-flammable building materials
F30-B fire-retardant / flammable building materials
F90-A fireproof / non-flammable building materials
F30-AB fire-retardant / non-flammable and flammable building materials
A1 non-flammable building materials
A2 non-flammable building materials
B1 flammable building-materials
B2 flammable building materials
No organic components With organic components Hardly inflammable Normal flammable
Basic principles. Building materials.
![Page 10: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/10.jpg)
Fire resistance classes acc. to DIN 4102 are designated with abbreviations depending on the component:
Examples of fire resistance classes:Walls, ceilings, supports F 30 / 60 / ...Fire walls F 90 / 120 / ..FS separations (doors, etc.) T 30 / 60 / ..Cable sealings S 30 / 60 / 90 / ...Installation ducts I 30 / 60 / 90 / ...Conduit entries R 30 / 60 / 90 / ...
Basic principles. Fire resistance class.
![Page 11: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/11.jpg)
• Inadequate fire protection is not coveredunder VOB or BGB, but is regarded as adeliberately concealed defect.
• 30-year liability for concealed defects.• In the event of harm to persons (death) the
laws of the StGB § 319 (violation of building regulations endangering public safety) and § 323a (full intoxication) apply in full.
Fire protection according to the criminal code.
![Page 12: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/12.jpg)
• Inadequate fire protection is not coveredunder VOB or BGB, but is regarded as adeliberately concealed defect.
• 30-year liability for concealed defects.• In the event of harm to persons (death) the
laws of the StGB § 319 (violation of building regulations endangering public safety) and § 323a (full intoxication) apply in full.
(1) Any person who, during the planning, management or execution of the construction of a building … violates the generally accepted rules of technology and in so doing endangers the body or life of another person shall be punished by being sentenced to a term of imprisonment of up to five years or by a fine.(2) Equally, any person shall be punished who, in the execution of his profession or trade, violates the generally accepted rules of technology during the planning, management or execution of a plan to install technical equipment in a building, or to change installed equipment of this kind, and as a result endangers the body or life of another person.(3) Any person who causes the danger by negligence shall be punished by being sentenced to a term of imprisonment of up to three years or by a fine.(4) Any person who, in the cases as per paras. 1 and 2, acts negligently and causes the danger by reason of his negligence, shall be punished by being sentenced to a term of imprisonment of up to two years or by a fine.
§ 319 Violation of building regulations
Fire protection according to the criminal code.
![Page 13: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/13.jpg)
AFS technology.
![Page 14: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/14.jpg)
AFS technology.
![Page 15: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/15.jpg)
AFS technology.
![Page 16: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/16.jpg)
KAISER completes the range of fire protection products.
![Page 17: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/17.jpg)
Fire-protection FlamoX H housing
For the installation of luminaires and loudspeakers in fire-protection ceilings..
Applications.
![Page 18: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/18.jpg)
Fire-protection FlamoX H housing
For the installation of luminaires andloudspeakers in fire-protection ceilings..
Applications.
![Page 19: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/19.jpg)
Fire protection one-gang boxes HWD 90
For the installation of switches, sockets in fire-protection walls.
Applications.
![Page 20: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/20.jpg)
Fire-protection one-gang boxes HWD 30
For attached luminaires, motion and firedetectors in fire-protection ceilings
Applications.
![Page 21: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/21.jpg)
Fire-protection one-gang box HWD 90 with screw-on cover
For installation as a junction box in fire protection walls.
Applications.
![Page 22: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/22.jpg)
Box sealing system DS 90
For the wall entry and feed-through (EI 90) of cable bundles or individual electrical installation conduits.
Applications.
![Page 23: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/23.jpg)
Cable sealing system LS 90
For the wall entry and feed-through (EI 90) of5-15 mm electrical installation cables.
Applications.
![Page 24: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/24.jpg)
Conduit sealing system RS 90
For the wall entry and feed-through (EI 90) of M16/20/M25 electrical installation conduits.
Applications.
![Page 25: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/25.jpg)
Examples of necessary sealings.
![Page 26: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/26.jpg)
Lightweight partition wall 1. Seal e.g. mineral fibre,Melting point >1000°C,Room weight >=90 kg/m³, max. annular gap width 50 mm(e.g. exact-fitting insulating shells)
2. Seal with building materials (component thickness) which intumesce if a fire breaks out, max, annular gap width 15 mm
3. Sealing with wall manufacturer’s gypsum mortar in boarding thickness
Sealing in accordance with MLAR.
![Page 27: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/27.jpg)
Solid partition wall 1. Seal e.g. mineral fibre,Melting point >1000°C,Room weight >=90 kg/m³, max. annular gap width 50 mm(e.g. exact-fitting insulating shells)
2. Seal with building materials (component thickness) which intumesce if a fire breaks out, max, annular gap width 15 mm
3. Seal with mortar in thickness of min 40 mm)
Sealings in accordance with MLAR.
![Page 28: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/28.jpg)
Training courses and processing regulations for sealings.
• Processing regulations for craftsmen carrying out the work (a lot of training is needed)
• On-site stirring and processing of auxiliary materials
![Page 29: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/29.jpg)
• insufficient filling depths
• create a bulge
• takes a long time
• unclear processing
• reworking in some cases
• faulty processing
• large number of different components
• a lot of training needed
• retrofitting is difficult
Disadvantages of today’s sealings.
![Page 30: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/30.jpg)
• insufficient filling depth
• creates a bulge
• takes a long time
• unclean processing
• reworking in some cases
• faulty processing
• large number of different components
• a lot of training needed
• retrofitting is difficult
• guarenteed sealing
• without bulging
• fast and easy
• clean processing
• no reworking
• fault-free
• only one article
• no training needed
• easy retrofitting
Goals for KAISER sealings.
![Page 31: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/31.jpg)
Sealings of feed-throughs with more than one cable.
• For wall entries and feed-throughs (EI 90)• Cable bundles up to 6 cables or for individual installation conduits up to M40• Up to 3-way group arrangement
![Page 32: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/32.jpg)
Installation.
Hole Ø 74 mm. Multi 4000.Insert seal cylinder.FX4 screw.
Bayonet fitting.
![Page 33: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/33.jpg)
Retrofitting.
Into the wall.
Through the wall.
Easy retrofitting.
![Page 34: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/34.jpg)
Cable and Conduit arrangement .
• Group arrangement (spacing 91) up to 3 box seals
• Also as reserve seal• Up to 6 NYM cables 5x1.5²• Up to 6 NYM cables 5x2.5²• Up to 3 coaxial cables• Up to 3 EDP/network cables • Up to 3 IY(ST)Y 20x2x0.6²• Individual installation conduits
up to M40
![Page 35: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/35.jpg)
2-part:• Processing around existing
cables or conduits
• Easy and fast installation
Product characteristics of sealing cylinder.
![Page 36: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/36.jpg)
FX4 screw:• well-known, tried and tested fitting
method• fast, safe installation
Product characteristics of sealing cylinder.
![Page 37: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/37.jpg)
Radii in rear area::• no sharp edges• no damage to cables with wall
entries
Product characteristics of sealing cylinder.
![Page 38: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/38.jpg)
Hingend device:• processing around existing cables
or conduits• easy, non-destructive retrofitting is
possible at any time
Produkteigenschaften Dichtelement.
![Page 39: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/39.jpg)
Product characteristics of sealing element.
Bayonet fitting:• secure mechanical fitting• easy installation and removal
![Page 40: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/40.jpg)
Sealing element:• smoke-proof room separation
(including against cold smoke)• no closing of the gusset required
Product characteristics of sealing element.
![Page 41: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/41.jpg)
Product characteristics of box sealing system DS 90.
Opposing installation:• for wall feed-throughs and entries • no filling with insulating material
necessary
![Page 42: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/42.jpg)
Product characteristics of box sealing system DS 90.
Material forms insulation layer:• intumesces if a fire breaks out• closes wall feed-throughs and entries
automatically and safely
![Page 43: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/43.jpg)
Test passed, approval applied for.
EOTA approval (European Organisation for Technical Approvals):
• fire-proof and smoke-proof room separation for at least 90 minutes (EI 90) • visible, certified protection without on-site processing of auxiliary materials
• maximum security and safety in fire protection
![Page 44: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/44.jpg)
Additional advantages.
Installation without fire protection foam, fire protection putty or fire protection mortar:
• avoids insufficient filling depths • no opened, encrusted cartridges• no limit on service life of opened cartridges• no need to use special tools• no bulge or additonal planking necessary• no need for training• faster, safer sealing (EI 90)
![Page 45: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/45.jpg)
Sealing of a cable.
![Page 46: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/46.jpg)
Into the wall.
Through the wall.
Verarbeitung.
![Page 47: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/47.jpg)
Sealing of a conduit.
![Page 48: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/48.jpg)
Cut hole Ø 35 mm. MULTI 4000.
Sealing of a conduit.
![Page 49: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/49.jpg)
Installation in masonry or concrete construction.
InstallationMake 20 mm drill hole and insert cableFit seal around the cablePress seal on both sides into the openingApply the identification tag
![Page 50: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/50.jpg)
Installation in masonry or concrete construction.
InstallationMake 32 mm drill hole and insert the cableRemove the pull-off lugFit the seal around the cablePress the seal on both sides into the
openingApply the identification tag
![Page 51: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/51.jpg)
Product characteristics of conduit sealing system RS 90.
Opens up:• processing around existing
conduits
• easy, fast installation
![Page 52: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/52.jpg)
Product characteristics of conduit sealing system RS 90.
Flexible material:• permits the introduction of
different conduit sizes
• use of conduit sizes M16, M20 or M25
![Page 53: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/53.jpg)
Product characteristics of conduit sealing RS 90.
Material forms an insulating layer:
• intumesces if a fire starts
• closes wall feed-throughs and entries automatically and safely
![Page 54: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/54.jpg)
Product characteristics of conduit sealing RS 90.
Pull-off lug:• use in solid walls
• easy, toolless adaptation to Ø 32 mm drill holes
![Page 55: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/55.jpg)
More advantages.
Installation without fire-protection foam, putty or mortar:
• avoids insufficient filling depths • no opened, encrusted cartridges• no limit on service life of opened cartridges• no need to use special tools• keine Ausleibung oder Aufdoppelung notwendig• no need for training• faster and safer sealing (EI 90)
![Page 56: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/56.jpg)
Product characteristics of cable sealing system LS 90.
Opens up:• processing around existing
cables
• easy, fast installation
![Page 57: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/57.jpg)
Flexible material:• permits the use of different
cables
• use of cable diameters from 5 to 15 mm
Product characteristics of cable sealing system LS 90.
![Page 58: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/58.jpg)
Product characteristics of cable sealing system LS 90.
Material forms an insulating layer:
• intumesces if a fire starts
• closes wall feed-throughs and entries automatically and safely
![Page 59: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/59.jpg)
EOTA approval (European Organisation for Technical Approvals):
• fire-proof and smoke-proof room separation (EI 90) for at least 90 minutes • visible, certified protection without on-site processing of auxiliary materials
• maximum safety in fire protection
Test passed, approval applied for.
![Page 60: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/60.jpg)
More advantages.
Installation without fire protection foam, fire protection putty or fire protection mortar:
• avoids insufficient filling depths • no opened, encrusted cartridges• no limit on service life of opened cartridges• no need to use special tools• no bulge or additonal planking necessary• no need for training• faster, safer sealing (EI 90)
![Page 61: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/61.jpg)
Identification of the sealings.
Proof
• All sealings must be identified• Identification tag in 4 languages
- D/GB, F, I- D/GB, NL, F
![Page 62: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/62.jpg)
Technical data.
Identification tag
• for all KAISER sealings
• made of plastic
• with two 4.5 mm drill holes
![Page 63: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/63.jpg)
Box sealing system DS 90.
• Safe, visible, certified fire sealings • For wall feed-throughs and entries• No filling or smearing • Automatic sealing of the joints and gusset• Non-destructive retrofitting of cables • For cable bundles or individual installation
conduits
![Page 64: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/64.jpg)
Cable sealing system LS 90.
• Safe, visible, certified fire sealings• For wall feed-throughs and entries• No filling or smearing• Also for use as wall entry • Automatic sealing of the joints• For cables of Ø 5-15 mm
![Page 65: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/65.jpg)
Conduit sealing system RS 90.
• Safe, visible, certified fire sealings• No filling or smearing • Also for use as wall entry • Automatic sealing of the joints • For M16-M25 conduits
![Page 66: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/66.jpg)
FlamoX-E
Art. No. 9435-01
FlamoX-E
Art. No. 9435-02
FlamoX-H
Art. No. 9430-01
Fire protection putty
Art. No. 9400-05
The product range
![Page 67: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/67.jpg)
One-gang box HWD 90
Art. No. 9463-01
One-gang junction box HWD 90
Art. No. 9464-01
The product range
![Page 68: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/68.jpg)
Ceiling box HWD 30
Art. No. 9463-50
Ceiling junction box HWD 30
Art. No. 9464-50
Fire-protection coverHWD 30 - 90
Art. No. 1184-94
The product range
![Page 69: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/69.jpg)
Box sealing system DS 90
Art. No. 9459-03
Cable sealing system LS 90
Art. No. 9459-01
Conduit sealing system RS 90
Art. No. 9459-02
The product range
Identification tag
Art. No. 9473-91, -92
![Page 70: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/70.jpg)
Box sealing system DS 90
Art. No. 9459-03
Cable sealing system LS 90
Art. No. 9459-01
Conduit sealing system RS 90
Art. No. 9459-02
The product range
Identification tag
Art. No. 9473-91, -92
![Page 71: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/71.jpg)
One-gang box HWD B15
- for thin boarding
Art. No. 9463-14
One-gang junction boxHWD B15
- for thin boarding
Art. No. 9464-15
The product range
One-gang box HWD B15
Art. No. 9463-15
One-gang junction box HWD B15
Art. No. 9464-15
One-gang box HWD B15
Art. No. 9461-15
One-gang box HWD B15
- for thin boarding
Art. No. 9461-14
![Page 72: Brandgennemføringer](https://reader034.fdocuments.net/reader034/viewer/2022051519/568c49f21a28ab49169630dd/html5/thumbnails/72.jpg)
Light & Building 2010.
2010Thank you. Stefan Born