8/14/2019 Bimini BWC Crown High Efficiency Gas Fired Hot Water Boiler Brochure
1/6
ResidentialEf cienciesup to 95.4%
A.F.U.E.
CommercialThermal
Ef cienciesup to 93.1%
-
8/14/2019 Bimini BWC Crown High Efficiency Gas Fired Hot Water Boiler Brochure
2/6
CROWNsresponseto the questfor highef ciency
Todays homes are tightly constructed to seal them rom dra ts that are uncom ortable and wasteenergy. Contemporary li estyles demand abundant hot water supplies or radiant heating, largeamounts o domestic hot water, pools, Jacuzzis, towel warmers and or snow melting applicationsto minimize the hazards o winter. And with todays rising energy costs, consumers are consideringhigh e ciency condensing boilers, especially those that meet the ederal Energy Star requirements.To meet these greater per ormance demands, new high e ciency condensing boilers have been
developed to deal with variable operating temperatures and fow rates, requent cold starts and quick response between space heating demands and demands or domestic hot water. This is where theBimini ts the bill.New technologies in materials and control systemsEmploying the latest cast aluminum metallurgy andadvanced burner control technologies, CROWNs BiminiSeries is more e cient than conventional boilers, and achievese ciencies up to 95.4% A.F.U.E.Once morning warm-up is complete, heating demand during therest o the day may only call or a small percentage o thetotal boiler output. Typically, boilers operate at one ring rate,and turn on and o to provide the desired amount o heat.The Bimini utilizes a microprocessor control system tomonitor heating needs and to automatically adjust the
ring rate to minimize the amount o uel consumed.Regulating the boiler to partial loads requires a burner witha high turndown capability. The Biminis modulating controlsystem tracks the demand or space heat and domestic hot
water, and senses the supply water temperature and outdoortemperature to precisely adjust heat output.
Pre-mix burner The Bimini is equipped with a pre-mix, stainless steel burnersystem which meters the precise amount o uel and air tooptimize combustion at any ring rate. An important bene tis that the resulting combustion process is clean burning and
very quiet. Aluminum heat exchangersBimini eatures low-mass, cast aluminum heat exchangers superiorcorrosion resistancean important attribute or
BW
-
8/14/2019 Bimini BWC Crown High Efficiency Gas Fired Hot Water Boiler Brochure
3/6
condensing boilers. Aluminum can be cast intointricate designs that improve heat trans er e ciency.Flow paths on both the combustion side and the waterside are engineered to optimize e ciency.
Why a condensing boiler Condensing design is necessary in a very high e ciencyboiler. When the boiler is operating at maximum
e iciency the exhaust temperatures become so low that water vapor in the exhaust condenses. The boiler mustbe designed to drain away this liquid.
Sealed combustion with multiple venting optionsBiminis sealed combustion design isolates the combustionprocess in your boiler rom the air in your home. Thissaves energy dollars by using combustion air rom outside,rather than room air youve already paid to heat. Verticalor horizontal venting is available to accommodate variousinstallations.
Bimini is ef cient in many waysBimini uses less foor space than other similarly sizedboilers, and the smaller sizes can be hung on the wall.Bimini is lighter in weight than conventional boilers.The Bimini is designed or easy installation. Water andgas piping are conveniently located, and electricalcomponents are prewired. A terminal strip is provided
or quick and easy eld wiring.Domestic Hot Water Priority Bimini is designed to partner with the Mega-StorIndirect Water Heater to provide domestic hot watere ciently.
All modelscan be vented directly
through the wall
BWC070, 090,120 and 151
Features of the Bimini Residentialand Commercial boilers
Condensing design Approved or closet installation Models BWC070/090/120/151 may beinstalled on non-carpeted combustible
sur aces when mounted on optional pbase.Models BWC150/425 may be installenon-carpeted combustible sur ace.Quiet operation, even at high ring raSupply water temperatures up to 180degrees F Low emissions o CO and NOX
Standard Equipment
Microprocessor-based control system wDigital touch pad and display Direct spark ignition Outdoor reset temperature sensor Domestic hot water priority Pump controls or heating and domhot water Fully modulating burner Cast aluminum heat exchanger TACO circulator
Probe low-water cuto Deluxe powder coated steel jacket wtwo-toned textured nish Factory assembled, pre-wired and packaged
For Models BWC070, 090,120 and 151
Wall mounting bracket standard Concentric polypropylene vent systemstandard Optional adapter or venting with staisteelOptional foor mounting pedestal kit
BWC150, 225 and 300
Can be vented with the concentripolypropylene system using an option
adapter
-
8/14/2019 Bimini BWC Crown High Efficiency Gas Fired Hot Water Boiler Brochure
4/6
Withtodays highenergy costs, owners
o commercial properties want boilers that provideoptimum com ort at the lowestcost. So, they are choosing the BiminiCommercial with thermal e ciency ratingsup to 93.1%.
Maximum e ciency is achieved by modulating the boilersoperation to meet the changing heat requirements over thecourse o the day. To handle large acilities, multiple Biminiboilers can be installed.
The Bimini is ruggedly built to provide years o service. It usesthe latest o microprocessor controls or e ciency and sa ety.
Vent length can reach up to 100 eet. For the BWC300,concentric polypropylene venting is available which means onlya single terminal outside or a cleaner look.
The Bimini can be installed on non-carpeted combustible sur aces,and is approved or installation in a closet.
For ease o installation, it is actory assembled, pre-wired and packaged.
Quiet operation.
Features of theBimini Commercial
Designed or commercialbuildings with large BTU loads
Suitable or multiple boilerinstallations Rugged Commercial gradconstruction
Input or External 0-10VDModulation Signal is standar(no need or AM-4 module
Easy access to an and gasvalve assembly
BWC300 may be vented with 100/150 concentric vent
Redundant pressure switch system:
Normally open switch proves air fow
Normally closed switch prevents boiler operation at
excessive vent pressures Control/gas valve systems similar to those o the residential Bimini
-
8/14/2019 Bimini BWC Crown High Efficiency Gas Fired Hot Water Boiler Brochure
5/6
snoitacificepS
2.59000,39000701000,021kcolbonom021CWB5.49000,070000,8000,09kcolbonom090CWB4.59000,550003,6000,07kcolbonom070CWB
1.39000,711000,
,2.59000117,00035,1000,051kcolbonom151CWB
531000,0513051CWB2.49000,671000,202000,5224522CWB
.sleufhtobrofemasehterasgnitaR.enaporprofLEdnasaglarutanrofNExiffusddA*
.E.O.D
GNITAEH YTICAPAC)rh / UTB(
TENRBIGNITAR)rh / UTB(
)%(EUFA*LEDOM FO.ON SNOITCES
MUMIXAMTUPNI
)rh / UTB(
snoisnemiD
"D"TNEVTELNIRIA
712 / 1-138 / 7-71021CWB
"3"44 / 1-224 / 3-348 / 3-32051CWB"4"44 / 1-224 / 3-3472522CWB
tneVcirtnecnoCmm001 / 0620-1/22 / 1-13-7 7/81151CWB tneVcirtnecnoCmm521 / 08
"C""B""A"*LEDOMSRETEMAIDRALLOC
712 / 1-138 / 7-71090CWB tneVcirtnecnoCmm001 / 06712 / 1-138 / 7-71070CWB tneVcirtnecnoCmm001 / 06
Important: This boiler requires a special venting system. Read instructions carefully before installing.
THE BWC BOILERS ARE APPROVED FOR CLOSET INSTALLATION WITH THE FOLLOWING CLEARANCES: Models BWC070/090/120/151: T op = 7-1/2,Fr ont = 3/4, Sides = 1/4, Bottom = 1-1/8 Models BWC150/225:T op = 5,Fr ont = 3/4", Sides = 1/2", Rear = 0
Models BWC070/090/120/151 may be installed on non-carpeted combustible surfaces when mounted on optional pedestal base . Models BWC150/225 may be installed on non-carpeted combustible surface.
BWC 150/225
BWC 070/090/120/151
-
8/14/2019 Bimini BWC Crown High Efficiency Gas Fired Hot Water Boiler Brochure
6/6
Since 1949, homeowners have depended on usfor quality, value and service
3633 I Street, P. O. Box 14818Philadelphia, PA 19134Phone: (215) 535-8900 Fax: (215) 535-9736
Visit us on the web: www.crownboiler.com
BWC-7/08-(20PN
AVAILABLE FROM:
Important: This boiler requires a special venting system. Read instructions carefully before installing.
+ BWC425 meets Z21.13 requirements. Consult actory or availability o CSD-1 compliant gas train.Clearances to combustible and non-combustible construction:This boiler is approved or closet installation with the ollowing clearances:Top = 7 Front = 3/4 Sides = 1/2 Rear = 8-1/2 Boiler may be installed on non-carpeted combustible sur aces.Recommended service clearances:Top = 24 Front = 24 Rear = 24 RH Side = 24 These service clearances are recommended, however they may be reduced to the combustible clearance listed above.1) Access to the ront o the boiler is provided through a door 2) Access is provided to the condensate trap and controls/trim located on the back o the boiler WHEN ORDERING
1. Ratings are reduced at altitudes above 2,000 t.2. Please speci y uel (natural gas or LP gas).3. Specifcations and dimensions are subject to change without notice.
BWC 300/399/425
High ef ciency, condensing,gas- red, hot water boiler