Bill 3 G - Thermal & Moisture.pdf
Transcript of Bill 3 G - Thermal & Moisture.pdf
-
7/27/2019 Bill 3 G - Thermal & Moisture.pdf
1/5
GUtech GERMAN UNIVERSITY OF TECHNOLOGY IN OMAN - PHASE 1
MAIN WORKS PACKAGE BILL No. 3 : Main Building
SECTION G : THERMAL & MOISTURE PROTECTION
Unit Amount
Item Description Quantity Unit Rate R.O Bz
The Contractor is referred to the Specifications
and Drawings for all details related to this Section
of the works and he is to include for complying
with all the requirements contained therein
Roof Covering
Roofing system consists of screed laid to falls with
4 mm torch applied membrane water proofing and
100 mm thick insulation finished with white cementtiles on cement mortar bedding over terram sheet
A Screed laid to falls 4350 m2
B Water proofing system 4350 m2
C Vertically, along roof slab / parapet junction
including corner fillet 681 m
D Edge flashing all as shown on External wall details
drg. no. AR.4.D34.003.020.05.00.A.1 681 m
E Terrace paved area as shown in Roof Plan 805 m2
F Allow for water proofing around drainage out lets,
pipes and the like 1 Item
To Collection
SECTION G : THERMAL & MOISTURE PROTECTION
GU tech - Main Contract WorksBill 3: Section G: Thermal and Moisture Protection
Date: August 2010 73 Majan Engineering (QS Division)
-
7/27/2019 Bill 3 G - Thermal & Moisture.pdf
2/5
GUtech GERMAN UNIVERSITY OF TECHNOLOGY IN OMAN - PHASE 1
MAIN WORKS PACKAGE BILL No. 3 : Main Building
SECTION G : THERMAL & MOISTURE PROTECTION
Unit Amount
Item Description Quantity Unit Rate R.O Bz
SECTION G : THERMAL & MOISTURE PROTECTION
Sub-structure waterproofing
Approved type waterproofing to concrete surfaces
A Laid horizontally and vertically 22,004 m2
Polythene sheet damp proof membrane
B 1000 gauge 10,212 m
Wet area waterproofing
Floor Slab Water proofing system
C Screed in bath room, toilet and Kitchen areas 753 m
D Screed in second floor court yard 416 m
E Screed in amphiteatre area 539 m
F Water proofing laid horizontally to wet floor areas1,708 m
2
G Water proofing laid vertically, along floor / wall
junction including cement sand fillet 1,175 m
To Collection
GU tech - Main Contract Works
Bill 3: Section G: Thermal and Moisture Protection
Date: August 2010 74 Majan Engineering (QS Division)
-
7/27/2019 Bill 3 G - Thermal & Moisture.pdf
3/5
GUtech GERMAN UNIVERSITY OF TECHNOLOGY IN OMAN - PHASE 1
MAIN WORKS PACKAGE BILL No. 3 : Main Building
SECTION G : THERMAL & MOISTURE PROTECTION
Unit Amount
Item Description Quantity Unit Rate R.O Bz
SECTION G : THERMAL & MOISTURE PROTECTION
Sundries
A Allow for water proofing to under ground water
tanks with plaster and fibre glass lining to internal
and approved water proofing to external face
1 Item
B Allow for water proofing to roof -top water tanks
with plaster and fibre glass lining to internal 1 Item
To Collection
GU tech - Main Contract Works
Bill 3: Section G: Thermal and Moisture Protection
Date: August 2010 75 Majan Engineering (QS Division)
-
7/27/2019 Bill 3 G - Thermal & Moisture.pdf
4/5
GUtech GERMAN UNIVERSITY OF TECHNOLOGY IN OMAN - PHASE 1
MAIN WORKS PACKAGE BILL No. 3 : Main Building
SECTION G : THERMAL & MOISTURE PROTECTION
Unit Amount
Item Description Quantity Unit Rate R.O Bz
SECTION G : THERMAL & MOISTURE PROTECTION
Other Items
Contractor shall list here other items not included
above but included in the specifications and
drawings and necessary for the complete and
satisfactory completion of this section of the works.
Such items shall be deemed to be included unless
specifically listed here
To Collection
GU tech - Main Contract Works
Bill 3: Section G: Thermal and Moisture Protection
Date: August 2010 76 Majan Engineering (QS Division)
-
7/27/2019 Bill 3 G - Thermal & Moisture.pdf
5/5
GUtech GERMAN UNIVERSITY OF TECHNOLOGY IN OMAN - PHASE 1
MAIN WORKS PACKAGE BILL No. 3 : Main Building
SECTION G : THERMAL & MOISTURE PROTECTION
Unit Amount
Item Description Quantity Unit Rate R.O Bz
SECTION G : THERMAL & MOISTURE PROTECTION
Collection
Page
73
74
75
76
BILL NO 3
SECTION G - THERMAL & MOISTURE
PROTECTION
CARRIED TO BILL NO. 3 SUMMARY
GU tech - Main Contract Works
Bill 3: Section G: Thermal and Moisture Protection
Date: August 2010 77 Majan Engineering (QS Division)