BigCal Calibration E04-108&04-019

Wei Luo

Lanzhou University, China

January 2008 Hall C Users Meeting

Page 2: BigCal Calibration E04-108&04-019 Wei Luo Lanzhou University, China January 2008 Hall C Users Meeting.

Outline

1. Introduction 2. Calibration method 3. Calibration 4. Radiation damage 5. Energy resolution 6. Summary

Page 3: BigCal Calibration E04-108&04-019 Wei Luo Lanzhou University, China January 2008 Hall C Users Meeting.

1. Introduction TF1-0 type lead glass, 12-stage Russian FEU-84 PMT, coupled by

1cm soft optical ‘cookie’. Protovino part: 1024 bars of 3.8x3.8x45cm3 lead glass RCS part: 720 bars of 4.0x4.0x40cm3 lead glass BigCal goal: identify elastic event, reduce high background rate

Page 4: BigCal Calibration E04-108&04-019 Wei Luo Lanzhou University, China January 2008 Hall C Users Meeting.

Kinematics table

Kin Ebeam(Gev) Ee(Gev) Distance(cm) Angle(°) Absorber(cm)

1 2.717 1.102 960 60.3 10.0

2 1.032 0.662 960 60.3 10.0

3 2.533 1.072 960 60.3 10.0

4 4.045 1.274 605 60.3 10.0

5 1.867 0.535 493.2 105.1 2.5

6 2.839 1.507 1200.0 44.9 10.0

7 3.680 2.207 1116.0 32.6 10.0

Page 5: BigCal Calibration E04-108&04-019 Wei Luo Lanzhou University, China January 2008 Hall C Users Meeting.

2. Calibration Method

where k=1,1744 Solve 1744 linear equations (3) for calibration coefficients Cj,

Use Cj to calculate new High Voltage. 1ADC channel=1Mev

VeA

1744

1

1744

1

jkjj

iiki

jijji

ijjij

XCAE

ACE

ACE

i

ikijjk AAX

E—electron energy (e_hms)

A—ADC value

C—calibration coefficient

i—event number

j—block number

(1)

(2)

(3)

(4)

Page 6: BigCal Calibration E04-108&04-019 Wei Luo Lanzhou University, China January 2008 Hall C Users Meeting.

3. Calibration

Use HMS information to select elastic electrons:

HMS predicted energy; HMS predicted & BigCal Position correlation; Max energy cluster.

Page 7: BigCal Calibration E04-108&04-019 Wei Luo Lanzhou University, China January 2008 Hall C Users Meeting.

Position Correlation

HMS predicted position

BigCal cluster position VS. HMS predicted position

Assuming elastic scattering, use HMS track to calculate elastic electron hit position.

Reconstructed cluster

Page 8: BigCal Calibration E04-108&04-019 Wei Luo Lanzhou University, China January 2008 Hall C Users Meeting.

Example Kinematics 6, electron energy:1.507Gev, BigCal theta: 44.9o, 10cm Al absorber

Cluster ADC ADC/E_hms ADC/E_hms/gain

ADC mean=1459

Gain=ADC/E_hms=0.957

Energy resolution=12%

Page 9: BigCal Calibration E04-108&04-019 Wei Luo Lanzhou University, China January 2008 Hall C Users Meeting.

Calculated Calibration coefficient

HV calculationAfter solving formula (3) we can get calibration coefficient shown below. The mean calibration coefficient greater than 1, demands increase HV of BigCal. With formula (4), we can calculate new HV based the current HV. (note: negative HV)

HV differenceAmplitude

HV ratio

Page 10: BigCal Calibration E04-108&04-019 Wei Luo Lanzhou University, China January 2008 Hall C Users Meeting.

After loading new HV The gain of ADC shifted to1 after loading new HV The energy resolution improved by 0.5%

Cluster ADC ADC/E_hms

Page 11: BigCal Calibration E04-108&04-019 Wei Luo Lanzhou University, China January 2008 Hall C Users Meeting.

4. Radiation damage

The radiation damage of lead glass makes the energy resolution increased.

The gain of cluster ADC keep decreasing as beam on.

Page 12: BigCal Calibration E04-108&04-019 Wei Luo Lanzhou University, China January 2008 Hall C Users Meeting.

Gain VS. Time

Page 13: BigCal Calibration E04-108&04-019 Wei Luo Lanzhou University, China January 2008 Hall C Users Meeting.

Gain VS. Beam Charge

1’’ Al

Page 14: BigCal Calibration E04-108&04-019 Wei Luo Lanzhou University, China January 2008 Hall C Users Meeting.

5. Energy resolution

The relation of energy resolution and electron energy is defined as:

Where σ is the energy resolution, E is electron energy,

The first term includes all systematic block-to-block differences and calibration errors; the the second term contains the effect of photoelectron statistics; the third term represent the fluctuation in pedestal due to electronics noise.

The effect of 10cm Al absorber on energy resolution is significant.

E

C

E

BA

E

(5)

Page 15: BigCal Calibration E04-108&04-019 Wei Luo Lanzhou University, China January 2008 Hall C Users Meeting.

Energy resolution VS. Beam Charge

Page 16: BigCal Calibration E04-108&04-019 Wei Luo Lanzhou University, China January 2008 Hall C Users Meeting.

Energy resolution VS. Time

Page 17: BigCal Calibration E04-108&04-019 Wei Luo Lanzhou University, China January 2008 Hall C Users Meeting.

Kin Ee(Gev) Distance(cm) Angle(°) Absorber(cm) Energy resolution

1 1.102 960 60.3 10.0 10.4

2 0.662 960 60.3 10.0

3 1.072 960 60.3 10.0 10.6

2.5 7.1

4 1.274 605 60.3 10.0 11.2

5 0.535 493.2 105.1 2.5 11.5

6 1.507 1200.0 44.9 10.0 10.7

7 2.207 1116.0 32.6 10.0 11.7

Page 18: BigCal Calibration E04-108&04-019 Wei Luo Lanzhou University, China January 2008 Hall C Users Meeting.

Energy resolution*E1/2 VS. Elastic electron energy

E

CBEA

E

Red points -10 cm absorber

Blue points -2.5 cm absorber

Page 19: BigCal Calibration E04-108&04-019 Wei Luo Lanzhou University, China January 2008 Hall C Users Meeting.

kine 5 energy resolution

Nov 28 2007 Jan 17 2008

Page 20: BigCal Calibration E04-108&04-019 Wei Luo Lanzhou University, China January 2008 Hall C Users Meeting.

6. Summary

The BigCal calibration has been done at start of each kinematics (except 7).

Al absorber has strong effect on the energy resolution of BigCal.

The HV of BigCal increase approximately 86V comparing to the beginning of experiment.

The lead glass blocks cured itself partially when the beam is off for a long time.

Page 21: BigCal Calibration E04-108&04-019 Wei Luo Lanzhou University, China January 2008 Hall C Users Meeting.

Thank you!