Automatic Meter Management - Smart Energy International Mortel.pdf · Automatic Meter Management *...

23
18/07/2006 13:39:30 1 Automatic Meter Management * EURIDIS Association EURIDIS Association Deregulation and AMM * Solution offered by IEC62056-31 and EURIDIS M. Patrick MORTEL President

Transcript of Automatic Meter Management - Smart Energy International Mortel.pdf · Automatic Meter Management *...

Page 1: Automatic Meter Management - Smart Energy International Mortel.pdf · Automatic Meter Management * EURIDIS Association Deregulation and AMM * Solution offered by IEC62056-31 and EURIDIS

18/07/2006 13:39:30 1

Automatic Meter Management *

EURIDIS AssociationEURIDIS Association

Deregulation and AMM *Solution offered by IEC62056-31 and EURIDIS

M. Patrick MORTEL

President

Page 2: Automatic Meter Management - Smart Energy International Mortel.pdf · Automatic Meter Management * EURIDIS Association Deregulation and AMM * Solution offered by IEC62056-31 and EURIDIS

18/07/2006 13:39:30 2

• Introduction• IEC 62056-31• EURIDIS Association• Technical committees

- CONFORMANCE- EURIDIS 2- PLAN (IEC 61334-5-1)

• Conclusion

Summary

Page 3: Automatic Meter Management - Smart Energy International Mortel.pdf · Automatic Meter Management * EURIDIS Association Deregulation and AMM * Solution offered by IEC62056-31 and EURIDIS

18/07/2006 13:39:30 3

• The liberalization of the energy market created for the utilities new constraints and new needs.

• This step is often the occasion, in particular on t he metering level, to introduce new functions, having all the s ame objective :

-> Improve the customers management.

• The study of an AMM system is now almost systematic …… the use of standards is necessary !

Introduction

Page 4: Automatic Meter Management - Smart Energy International Mortel.pdf · Automatic Meter Management * EURIDIS Association Deregulation and AMM * Solution offered by IEC62056-31 and EURIDIS

18/07/2006 13:39:30 4

Standard =- Open solution,- Multi suppliers,- Evolutions …

… To prepare the future !

Standard Why ?

Page 5: Automatic Meter Management - Smart Energy International Mortel.pdf · Automatic Meter Management * EURIDIS Association Deregulation and AMM * Solution offered by IEC62056-31 and EURIDIS

18/07/2006 13:39:30 5

• Introduced at the beginning of the 1990's (by Elect ricité De France & ACTARIS), the protocol has been standardised by the international workgroup IEC TC13WG14.

• The standard has been evolved from IEC61142 to the actual IEC62056-31.

• It’s the only standardised protocol for the Automatic electricity Meter Reading with a twisted-pair cable.

• This standard is an efficient and low-cost open sol ution for AMM (including Off-site & Automatic Meter Reading).

• More than 10 million meters with an IEC 62056-31 in terface are installed in many countries (1 million more each ye ar).

IEC 62056-31 History of a standard

Page 6: Automatic Meter Management - Smart Energy International Mortel.pdf · Automatic Meter Management * EURIDIS Association Deregulation and AMM * Solution offered by IEC62056-31 and EURIDIS

18/07/2006 13:39:30 6

IEC 62056-31 Introduction

• The IEC 62056-31 standard is based on the installation of a bus connecting all meters of the same site.

Local busIEC 62056-31

Page 7: Automatic Meter Management - Smart Energy International Mortel.pdf · Automatic Meter Management * EURIDIS Association Deregulation and AMM * Solution offered by IEC62056-31 and EURIDIS

18/07/2006 13:39:30 7

• Security of the data

• Plug & Play : Automatic detection of equipments- Master / Slave system.- Each slave has a single address.- The master can collect automatically the addresses of the new slaves.

• No connecting and topology bus constraints- The bus is just an single twisted pair with screen

(example : Indoor telephone cable).

• Galvanic insulation- The bus accepts a temporary accidental connection

to the low voltage network.

IEC 62056-31 Main characteristics

Page 8: Automatic Meter Management - Smart Energy International Mortel.pdf · Automatic Meter Management * EURIDIS Association Deregulation and AMM * Solution offered by IEC62056-31 and EURIDIS

18/07/2006 13:39:30 8

IEC 62056-31 Example of architecture

• Single or associated with a narrow-band PLC network (IEC 61334-5-1) and a broadband PLC network, this solution can be an essential element of an OMR, AMR or AMM system.

Local busIEC 62056-31

Magnetic plug

Page 9: Automatic Meter Management - Smart Energy International Mortel.pdf · Automatic Meter Management * EURIDIS Association Deregulation and AMM * Solution offered by IEC62056-31 and EURIDIS

18/07/2006 13:39:30 9

Narrow-band PLCIEC 61334-5-1

Bus PLC Interface

PLC Concentrator

MV / LV

IEC 62056-31 Example of evolution

Ethernet

BroadbandPLC

Local busIEC 62056-31

Page 10: Automatic Meter Management - Smart Energy International Mortel.pdf · Automatic Meter Management * EURIDIS Association Deregulation and AMM * Solution offered by IEC62056-31 and EURIDIS

18/07/2006 13:39:30 10

• A non-profit organization created in 1990

• Members : manufacturers, utilities, software compan ies

• The objectives-To promote the use of the IEC62056-31 standard-To define and control technical specifications evolution-To be an agent for conformance testing-To inform members

EURIDIS Association

Page 11: Automatic Meter Management - Smart Energy International Mortel.pdf · Automatic Meter Management * EURIDIS Association Deregulation and AMM * Solution offered by IEC62056-31 and EURIDIS

18/07/2006 13:39:30 11

• The EURIDIS Association, whose the main objective i s the promotion of the IEC 62056-31 standard, is there to help the actors of the energy markets which they are sup pliers or users of AMM products.

• In order to adapt and to anticipate the new needs r elated to the deregulation, the association created severa l technical committees :- CONFORMANCE,- EURIDIS 2,- PLAN …

EURIDIS Technical committees

Page 12: Automatic Meter Management - Smart Energy International Mortel.pdf · Automatic Meter Management * EURIDIS Association Deregulation and AMM * Solution offered by IEC62056-31 and EURIDIS

18/07/2006 13:39:30 12

• Missions- Create and diffuse a list of conformance tests,- Record declarations of compliance.

• The list and the declarations are available on the EURIDIS web site.

• With this certification, EURIDIS guarantees the interoperability of the products.

CONFORMANCE Technical committee

Page 13: Automatic Meter Management - Smart Energy International Mortel.pdf · Automatic Meter Management * EURIDIS Association Deregulation and AMM * Solution offered by IEC62056-31 and EURIDIS

18/07/2006 13:39:30 13

CONFORMANCE List of tests

Page 14: Automatic Meter Management - Smart Energy International Mortel.pdf · Automatic Meter Management * EURIDIS Association Deregulation and AMM * Solution offered by IEC62056-31 and EURIDIS

18/07/2006 13:39:30 14

CONFORMANCE Declaration

Page 15: Automatic Meter Management - Smart Energy International Mortel.pdf · Automatic Meter Management * EURIDIS Association Deregulation and AMM * Solution offered by IEC62056-31 and EURIDIS

18/07/2006 13:39:30 15

• Scheduled reads,• More complex tariffs,• Load-profiles,• Remote disconnections,• Pre-paid,• Outage recording …

… more data, more frequently

AMM New needs = new functions

Page 16: Automatic Meter Management - Smart Energy International Mortel.pdf · Automatic Meter Management * EURIDIS Association Deregulation and AMM * Solution offered by IEC62056-31 and EURIDIS

18/07/2006 13:39:30 16

• To manage the standard evolutions to increase the r eal speed- Increase the “physical” speed

• 1200 -> 4800

- Increase the size of data which can be transmitted• Frames length

- Optimization of the transport of load profiles• Burst mode

• Compliant with EURIDIS 1- Physical layer -> Application layer

• Partnership with the SUPELEC High-school

EURIDIS 2 Technical committee

Page 17: Automatic Meter Management - Smart Energy International Mortel.pdf · Automatic Meter Management * EURIDIS Association Deregulation and AMM * Solution offered by IEC62056-31 and EURIDIS

18/07/2006 13:39:30 17

Narrow-band PLCIEC 61334-5-1

= PLAN SFSK

Bus PLC Interface

PLC Concentrator

MV / LV

IEC 61334-5-1 Introduction

Ethernet

BroadbandPLC

Local busIEC 62056-31

Page 18: Automatic Meter Management - Smart Energy International Mortel.pdf · Automatic Meter Management * EURIDIS Association Deregulation and AMM * Solution offered by IEC62056-31 and EURIDIS

18/07/2006 13:39:30 18

• Plug & Play / Self-management- Automatic detection of the devices present on a LV grid- Automatic synchronized repetition (= chorus)

• Robust modulation- S-FSK (Spread Frequency Shift Keying)- Frame synchronization of the zero crossing of the wave

PLAN / IEC 61334-5-1 Main characteristics

Page 19: Automatic Meter Management - Smart Energy International Mortel.pdf · Automatic Meter Management * EURIDIS Association Deregulation and AMM * Solution offered by IEC62056-31 and EURIDIS

18/07/2006 13:39:30 19

• To maintain the interoperability - EURIDIS 1&2 (IEC 62056-31) -> PLAN (IEC 61334-5-1)

• Introduce same evolutions in EURIDIS & PLAN- Increase the “physical” speed

• 1200 -> 4800

- Increase the size of data which can be transmitted• Frames length

- Optimization of the transport of load profiles• Burst mode

PLAN Technical committee

Page 20: Automatic Meter Management - Smart Energy International Mortel.pdf · Automatic Meter Management * EURIDIS Association Deregulation and AMM * Solution offered by IEC62056-31 and EURIDIS

18/07/2006 13:39:30 20

“ With these technical committees, the EURIDIS Association wishes to guarantee to the users of the IEC 62056-31 standard, an AMM system powerful and perennial. ”

Conclusion

Page 21: Automatic Meter Management - Smart Energy International Mortel.pdf · Automatic Meter Management * EURIDIS Association Deregulation and AMM * Solution offered by IEC62056-31 and EURIDIS

18/07/2006 13:39:30 21

• Easy (to deploy and use) & Low-cost

• Multi-suppliers

• IEC 62056-31

• PLC compliant

• 10 millions points over the world

Do you know that there is a standard which meets your needs in Do you know that there is a standard which meets your needs in OMR, AMR & AMM ?OMR, AMR & AMM ?

User or not, Make like our new members, Join us now !!!User or not, Make like our new members, Join us now !!!EURIDIS Association

www.euridis.org

To prepare the future Together

Page 22: Automatic Meter Management - Smart Energy International Mortel.pdf · Automatic Meter Management * EURIDIS Association Deregulation and AMM * Solution offered by IEC62056-31 and EURIDIS

18/07/2006 13:39:30 22

Experience Feedback

Metering International Issue 3 2005

Article :

“AMR System meets Romande Energie’s needs”

Page 23: Automatic Meter Management - Smart Energy International Mortel.pdf · Automatic Meter Management * EURIDIS Association Deregulation and AMM * Solution offered by IEC62056-31 and EURIDIS

18/07/2006 13:39:30 23

Contact

Thanks !

Contact :

www.euridis.orgE-Mail : [email protected]