Are your Digesters Burping, Frothing, or otherwise not ...

46
Are your Digesters Burping, Frothing, or otherwise not Behaving? Northeast Residuals and Biosolids Conference 2017| Burlington, VT October 27, 2017 Christopher Muller, PhD, P.E. Brown and Caldwell Brown and Caldwell: John Willis, Tom Chapman; Jonathan Keaney; Gary Newman; Lance Salerno and Perry Schafer NYCDEP: Luis Carrio and Peter Pianelli Nashville Metro: Taft McNeal

Transcript of Are your Digesters Burping, Frothing, or otherwise not ...

Page 1: Are your Digesters Burping, Frothing, or otherwise not ...

Are your Digesters Burping, Frothing, or otherwise not Behaving?

Northeast Residuals and Biosolids Conference 2017| Burlington, VT

October 27, 2017

Christopher Muller, PhD, P.E. Brown and Caldwell

Brown and Caldwell: John Willis, Tom Chapman; Jonathan Keaney; Gary Newman; Lance Salerno and Perry Schafer NYCDEP: Luis Carrio and Peter Pianelli Nashville Metro: Taft McNeal

Page 2: Are your Digesters Burping, Frothing, or otherwise not ...

• Is digesting sludge specific gravity of one? • What are the process implications? • Are there design modifications that can help

reduce the impact?

Presentation Outline

2 Brown and Caldwell 2

Page 3: Are your Digesters Burping, Frothing, or otherwise not ...

• Digesters are biologically complex, relying on a series of different microbial communities to reduce sludge mass.

• Not readily observable like open clarifiers or aeration basins •  View ports •  Cameras –DCWater has a new camera system inside the

digesters

•  This means that we typically make assumptions about the environment within the digester. •  Completely mixed •  Digested sludge specific gravity is close to 1

What is going on inside anaerobic digesters?

Brown and Caldwell 3

Page 4: Are your Digesters Burping, Frothing, or otherwise not ...

• Digesters produce significant amounts of digester gas as they convert raw sludge to biomass.

• Research on volume expansion has shown that at different viscosities the extent of gas hold up in the sludge changes •  Higher viscosity more gas hold up, lower the intensity of

mixing the lower the overall viscosity of the sludge. •  Mixing helps convey gas out of the sludge

Why might we think that SG = 1 is not correct?

Brown and Caldwell 4

Page 5: Are your Digesters Burping, Frothing, or otherwise not ...

What may be going on in your digesters

5 Brown and Caldwell

Page 6: Are your Digesters Burping, Frothing, or otherwise not ...

OWASA (Chapel Hill, NC) Measurements

6

  1st Stage

2nd Stage

3rd Stage

Pressure (ft WC) 22.6 19.3 15.8 Radar Surface (ft

WC) 30.4 23.3 19.0

Difference (ft) 7.8 4.0 3.2 Ave. Specific

Gravity 74.5% 82.6% 83.2%

Page 7: Are your Digesters Burping, Frothing, or otherwise not ...

Tallman Island digester wall temperature profile

7.5” WC Gas Pressure

Would expect wall temperature to be fairly uniform if completely mixed and uniform temperature inside

Brown and Caldwell

Page 8: Are your Digesters Burping, Frothing, or otherwise not ...

Level Suggested by Hydrostatic Pressure

Measurement

Level of Sludge Withdrawal Pipe

Temperature Group 1

Temperature Group 2

Temperature Group 3

Tallman Island External Wall Temperature

Page 9: Are your Digesters Burping, Frothing, or otherwise not ...

Sludge escaping from the fixed cover digesters in Nashville

Sludge on the covers of Hunts Point digesters

Why do we care?

• Process implications •  HRT ≠ MCRT

•  Mass in the system divided by mass wasted

•  Biosolids regulations written around MCRT

•  Could you see deteriorated performance •  Organic loading can be higher than

expected

• Operations and facilities impacts •  Surcharging of digester cover •  Tank overflows

Brown and Caldwell 9

Page 10: Are your Digesters Burping, Frothing, or otherwise not ...

Theoretical analysis of SG impacts on digester process metrics

10

Low SG Sludge

SG = 1 Sludge

Reduced SG Sludge

Simplified Model Used Reality is likely a stratified system

Page 11: Are your Digesters Burping, Frothing, or otherwise not ...

Heavily loaded digester example

Brown and Caldwell 11

Theoretical MCRT = 15 days Theoretical OLR = 0.16 lb-VS/ft3-day

OWASA SG Range

Page 12: Are your Digesters Burping, Frothing, or otherwise not ...

A detectable reduction in VSr may be difficult to see on a daily basis

Brown and Caldwell 12

Page 13: Are your Digesters Burping, Frothing, or otherwise not ...

• Reduced active volume can result in overloading at apparent loadings below stated design conditions. •  Especially if stratified and upper portion of the tank is not

available.

• Reduced residence time can result in a reduction in VSr resulting in increased biosolids production.

• Reduced residence time could impact biosolids stability (odors)

Potential process impacts summarized

Brown and Caldwell 13

Page 14: Are your Digesters Burping, Frothing, or otherwise not ...

How do we get low-specific-gravity digesting- sludge in our digesters

14

Page 15: Are your Digesters Burping, Frothing, or otherwise not ...

The idea revisited…

15

Page 16: Are your Digesters Burping, Frothing, or otherwise not ...

A design common to many digesters suggests we did not consider reduced SG.

16

33.80 -32.88 11” WC

Page 17: Are your Digesters Burping, Frothing, or otherwise not ...

Just to Note: This is Clearly NOT to Scale…

17

Page 18: Are your Digesters Burping, Frothing, or otherwise not ...

Our draw off should look more like this

18

Page 19: Are your Digesters Burping, Frothing, or otherwise not ...

What does this cause???

19

• The level in digesters is almost always higher.

Page 20: Are your Digesters Burping, Frothing, or otherwise not ...

What does this cause???

20

• The level in digesters is almost always higher. • Overflow “boxes” force the actual level higher.

Page 21: Are your Digesters Burping, Frothing, or otherwise not ...

What does this cause???

21

• The level in digesters is almost always higher. • Overflow “boxes” force the actual level higher. • Higher levels create foaming episodes.

Page 22: Are your Digesters Burping, Frothing, or otherwise not ...

What does this cause???

22

• The level in digesters is almost always higher. • Overflow “boxes” force the actual level higher. • Higher levels create foaming episodes.

Page 23: Are your Digesters Burping, Frothing, or otherwise not ...

What does this cause???

23

Ultimately: This can cause

Cover Failures

Page 24: Are your Digesters Burping, Frothing, or otherwise not ...

Tallman Island Trapping Low-SG Sludge in Upper Layers

7.5” WC Gas Pressure

Page 25: Are your Digesters Burping, Frothing, or otherwise not ...

7.5” WC Gas Pressure

Tallman Island Trapping Low-SG Sludge in Upper Layers

Page 26: Are your Digesters Burping, Frothing, or otherwise not ...

Hunts Point Wasting Configuration Similarly creates Low-SG Sludge Trap

26

Page 27: Are your Digesters Burping, Frothing, or otherwise not ...

Hunts Point Wasting Configuration Similarly creates Low-SG Sludge Trap

27

Page 28: Are your Digesters Burping, Frothing, or otherwise not ...

This doesn’t just happen in NYC: Nashville,

TN

28

Page 29: Are your Digesters Burping, Frothing, or otherwise not ...

This doesn’t just happen in NYC: Nashville,

TN

29

Page 30: Are your Digesters Burping, Frothing, or otherwise not ...

Potential Solutions

30

Page 31: Are your Digesters Burping, Frothing, or otherwise not ...

Tallman Island 7.5” WC Gas Pressure

Page 32: Are your Digesters Burping, Frothing, or otherwise not ...

Tallman Island Concept was Steel Plate

32

Page 33: Are your Digesters Burping, Frothing, or otherwise not ...

Hunts Point

33

Page 34: Are your Digesters Burping, Frothing, or otherwise not ...

Hunts Point concept is a pipe and valve

34

Page 35: Are your Digesters Burping, Frothing, or otherwise not ...

Nashville

35

Page 36: Are your Digesters Burping, Frothing, or otherwise not ...

Nashville’s Initial Contractor Fixes

36

.

Foam-Busting Surface Nozzle

Emergency “Hatch”

Radar Level Element

Page 37: Are your Digesters Burping, Frothing, or otherwise not ...

37

Nashville’s Current Improvements

Page 38: Are your Digesters Burping, Frothing, or otherwise not ...

Planned implementation for surface wasting at Nashville

Brown and Caldwell 38

Page 39: Are your Digesters Burping, Frothing, or otherwise not ...

For some Tanks, the “Fix” is FREE

39

Page 40: Are your Digesters Burping, Frothing, or otherwise not ...

For some Tanks, the “Fix” is FREE

40

Page 41: Are your Digesters Burping, Frothing, or otherwise not ...

Solution at Owls Head

Brown and Caldwell 41

Page 42: Are your Digesters Burping, Frothing, or otherwise not ...

Cautioned that surface wasting

was NOT the only digester

enhancement

Owls Head Conversion Performance

42

Page 43: Are your Digesters Burping, Frothing, or otherwise not ...

Owls Head Conversion Performance

43

Page 44: Are your Digesters Burping, Frothing, or otherwise not ...

Conclusions

Page 45: Are your Digesters Burping, Frothing, or otherwise not ...

Our assumptions surround sludge specific gravity in an anaerobic digester may not be correct • Consider whether this

explains some problems/experiences… • Consider what it means for your next

project (upgrade or new digesters)…

Conclusions

45

Page 46: Are your Digesters Burping, Frothing, or otherwise not ...

QUESTIONS? Christopher Muller, PhD, P.E. (978) 983–2059 [email protected]