Architecture and commissioning of the TCV distributed feedback plasma control system
description
Transcript of Architecture and commissioning of the TCV distributed feedback plasma control system
Ecole Polytechnique Fédérale de Lausanne (EPFL), Centre de Recherches en Physique des Plasmas, Association Euratom-Confédération Suisse, CH-1015 Lausanne, Switzerland
Upgrading our linear, PID coil current controller› Limited in the number of inputs/outputs› Unable to use the TCV ECRH system in feedback› Unable to add further diagnostic signals
Wanted to include the full TCV actuator set including› Coil currents› Gas valves› ECRH systems› Diagnostic systems
Using real time signals from many more diagnostics› Soft x-ray› Diamagnetic › Photodiodes› And more
A large expansion in the number of inputs and outputs was required
The new controller uses acquisition modules linked to PCs in a modular real time network.
Auto code generation (Simulink)
Some of the TCV actuators
Analogue IO: 384 inputs, 144 outputs Control rates 10 – 100 kHz. Several successful MHD instability and
profile control experiments already carried out.
Including full control of the TCV plasma discharge….
Come to my poster to learn more!