Architect Guide: CRAVE6048downloads.hearthnhome.com/architectGuides/Crave_CRAVE6048_Arch... ·...

3
Specifications Additional information can be found online at www.heatilator.com 51-1/8" [1299] 62" [1575] 15-5/8" [397] 42-1/2" [1080] 4" [102] 8-9/16" [217] 63" [1600] 8-9/16" [217] 1" [25] 58" [1473] 17-1/8" [435] 18-5/8" [471] 41-3/4" [1060] 2-3/8" [60] 8-9/16" [217] 24-1/2" [622] 8-7/8" [225] 2-3/4" [70] 7-1/4" [184] 23-3/4" [603] GAS ACCESS ELECTRICAL ACCESS CENTERED ON APPLIANCE Ø 8" [203] Please consult the manufacturer’s installation manual for all details and requirements before making a final design layout decision. Crave6048 48" Direct Vent Gas Fireplace Crave CRAVE6048 MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH GLASS SIZE CRAVE6048 Actual Framing Actual Framing Actual Framing Actual Framing 47-1/2 x 12-1/2 58 60-1/4 58 60-1/4 41-3/4 42 17-1/8 18-1/4 TOP FRONT LEFT RIGHT BEFORE FRAMING, PLEASE NOTE: A minimum of 24" of vertical venting is required before attaching any elbow to the appliance.

Transcript of Architect Guide: CRAVE6048downloads.hearthnhome.com/architectGuides/Crave_CRAVE6048_Arch... ·...

Specifications

Additional information can be found online at www.heatilator.com

51-1/8" [1299]62" [1575]

15-5/8"[397]

42-1/2"[1080]

4"[102]

8-9/16"[217]

63"[1600]

8-9/16"[217]

1" [25]58" [1473]

17-1/8"[435]

18-5/8"[471]

41-3/4"[1060]

2-3/8"[60]

8-9/16"[217]

24-1/2"[622]

8-7/8"[225]

2-3/4"[70]

7-1/4"[184]

23-3/4"[603]

GAS ACCESS ELECTRICAL ACCESS

CENTERED ON APPLIANCEØ 8" [203]

Please consult the manufacturer’s installation manual for all details and requirements before making a final

design layout decision.

Crave604848" Direct Vent Gas Fireplace

Crave CRAVE6048

MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH GLASS SIZE

CRAVE6048Actual Framing Actual Framing Actual Framing Actual Framing

47-1/2 x 12-1/258 60-1/4 58 60-1/4 41-3/4 42 17-1/8 18-1/4

TOP

FRONTLEFT RIGHT

BEFORE FRAMING, PLEASE NOTE:

A minimum of 24" of vertical venting is required before attaching any elbow to the appliance.

Crave CRAVE6048

25"[635]

24"[610]

13-1/8"[333]

16-3/4"[425]

52-5/16" [1329]

51" [1295]

49-3/16" [1249]

5/8" [16]27-5/16"

[692]

5-7/8"[149]

48-3/4" [1238]57-5/8" [1463]

12-5/8"[321]

21-3/8"[543]

27-5/16"[694]

5-7/8"[149]

49-1/8" [1248]57-1/2" [1461]

12-1/8"[308]

21-3/8"[543]

19-7/16"[494]

CLEAN FACE TRIM

FIREPLACE VIEWING AREA17-1/4"[438]

51-1/8" [1299]

OVERLAP FIT METHOD(FOUR SQUARE, ILLUSION)

FIREPLACE VIEWING AREA15-3/4"[400]

51-1/8" [1299]

INSIDE FIT METHOD(CLEAN FACE TRIM)

FOUR SQUARE FRONT ILLUSION FRONT

FRONT DIMENSIONS

FINISHED OPENING DIMENSIONS

Decorative Front Dimensions and Framing

• Rectangular holes on bottom of access panel should be covered.

• Approved for 0"-4" finishing material on inside fit method

• If finishing materials are 0-1” thick, the outer trim ring should be adjusted out so that the trim ring overlaps the finishing material. This is intended to provide the cleanest look.

• If finishing materials are 1-4” thick, install the trim ring all the way in. Finishing materials may not extend past the outside edge of the trim ring.

• Rectangular holes on bottom of access panel must be exposed.

• ONLY approved for 0"-1" finishing material on overlap fit method

• Rectangular holes on bottom of access panel must be exposed.

• ONLY approved for 0"-1" finishing material on overlap fit method

Specifications

GS/HTL/CRAVE6048_0618

PRODUCT LISTING CODES

US ANSI Z21.88-2014

CAN CSA 2.33-2014

UL307B

Additional information can be found online at www.heatilator.com

Product information provided is not complete and is subject to change without notice. Product installation must adhere strictly to instructions accompanying product to avoid risk of fire and potential injury.

Lakeville, MN Phone: (800) 927-6841Web: www.heatilator.com

APPLIANCE LOCATION

WALL PENETRATION

MANTEL LEG/WALL PROJECTIONS COMBUSTIBLE OR NON-COMBUSTIBLE

100-3/8"[2550]

70-3/4"[1797] 60-1/4

[1530]**

60-1/4[1530]**

60-1/4 [1530]**

60-1/4 [1530]**

18-1/4"[464]

28-1/2"[724] 1"

[25]

1"[25]

See clearancesin install manual

Refer to Section 10 of install manual for hearth, mantel and wall projection information. If a HEAT-ZONE® or HEAT-DUCT will be installed,refer to Section 5.E of install manual for information.

2 HEAT-ZONES = Add 4" to ** dimension1 HEAT-ZONE = Add 2" to ** dimension

FRAMING DIMENSIONS

CLEARANCES TO COMBUSTIBLES

42"[1067]

60-1/4"[1530]

10"[254]

HEADERDEPTH**

18-1/4"[464]

APPLIANCE MAY BE INSTALLED OFF OF FLOOR***

* Adjust framing dimensions for interior sheathing (such as sheetrock)** Header depth not to exceed 3-1/2".*** If appliance is installed off the floor, maintain required clearances to combustibles Construct platform in accordance with local building codes.

Note: All measurements in inches.

MEASUREMENTS FROM TOP EDGE OF THE APPLIANCE OPENING

4

5

6

13-16

3

2

1

67

89

1011

18

31

MAX.

MIN.

TO CEILING

Measurement from top edge of openingto bottom of appliance = 24-1/2 IN.

OVERLAP FIT

MEASUREMENTS FROM TOP EDGE OF THE APPLIANCE OPENING

4

5

6

14-16

0-910

18

31 MIN.

MAX.

TO CEILING

Measurement from top edge of openingto bottom of appliance = 24-1/2 IN.

7

11

INSIDE FITNote: All measurements in inches.

MEASUREMENT FROMTOP EDGE OPENING

18 2023

2629

31

TO CEILING

912

63

1

Measurement from top edge opening to bottom of appliance = 24-1/2"

MAX.

Note: All measurements in inches.

MANTEL PROJECTIONS - NON-COMBUSTIBLE

MANTEL PROJECTIONS - COMBUSTIBLE

63"[1600]

10" 12"

63"[1600]

Do not pack with insulation orother material

* Shows center of vent framinghole for top venting. Center of holeis 1" [25] above center of horizontalvent pipe.

3 ft. maximum4-1/2"minimum

FIREPLACE OPENINGSee Appliance dimension diagram in install manual - Dimension B

Note: Clearance from opening to perpendicualar wall

Top View

FIREPLACE OPENINGSee Appliance dimension diagram in install manual - Dimension B

Note: Clearance from opening to perpendicualar wall

Top View

7"minimum UNLIMITED

Acceptable on both sides of opening

48"[1219]

0"

1" [25]

1" [25]

31" [787]Top of

FireplaceOpening to

Ceiling0"

55-1/2"[1410]

Bottom ofFireplace to

Ceiling

Crave CRAVE6048