May 2000 MAPTIS Presentation 1 SME initiative Arc Tracking Test 18 from NASA-STD-6001 Purpose: Determine ability of wire insulation materials or constructions to resist arc tracking and access damage caused by initial arcing and restrike events Phenomena whereby an arc between two or more wires, once initiated, will sustain itself through a conductive path provided by degradation of the insulation for a measurable length

description

Arc Tracking Test 18 from NASA-STD-6001. Purpose: Determine ability of wire insulation materials or constructions to resist arc tracking and access damage caused by initial arcing and restrike events - PowerPoint PPT Presentation

Transcript of Arc Tracking Test 18 from NASA-STD-6001

Page 1: Arc Tracking Test 18 from NASA-STD-6001

May 2000 MAPTIS Presentation 1

SME initiative

Arc TrackingTest 18 from NASA-STD-6001

• Purpose: Determine ability of wire insulation materials or constructions to resist arc tracking and access damage caused by initial arcing and restrike events

• Phenomena whereby an arc between two or more wires, once initiated, will sustain itself through a conductive path provided by degradation of the insulation for a measurable length

Page 2: Arc Tracking Test 18 from NASA-STD-6001

May 2000 MAPTIS Presentation 2

SME initiative

Arc TrackingTest in Progress

• Typical Specimen– 7 wire bundle 46 cm in length

• Arc Initiation– Short circuit of conductor ends by dry

graphite powder• Test Conditions

– Worst-case environment– 5 kW, 400 Hz, 3-phase, 200 volt/ 50

amps RMS• Acceptance Criteria

– Wire configuration is resistant to arc tracking if it does not exhibit arc propagation on either initial or reapplication of power