Angle-resolved magnetometry for determination of magnetic …schnack/molmag/... · 2020. 7. 27. ·...

25
Angle-resolved magnetometry for determination of magnetic anisotropy in low symmetry environments: a few additions to the presentation of Dr. ShangDa Jiang Roberta Sessoli . Department of Chemistry and INSTM research unit, University of Florence ECMM 2013 Satellite workshop October 11-12, 2013 1

Transcript of Angle-resolved magnetometry for determination of magnetic …schnack/molmag/... · 2020. 7. 27. ·...

Page 1: Angle-resolved magnetometry for determination of magnetic …schnack/molmag/... · 2020. 7. 27. · Angle-resolved magnetometry for determination of magnetic anisotropy in low symmetry

Angle-resolved magnetometry for determination of

magnetic anisotropy in low symmetry environments:

a few additions to the presentation of

Dr. ShangDa Jiang

Roberta Sessoli.

Department of Chemistry and INSTM research unit, University of Florence

ECMM 2013 – Satellite workshop – October 11-12, 2013

1

Page 2: Angle-resolved magnetometry for determination of magnetic …schnack/molmag/... · 2020. 7. 27. · Angle-resolved magnetometry for determination of magnetic anisotropy in low symmetry

Techniques for the determination of the magnetic anisotropy

STM

Anisotropy parameters Anisotropy axes orientation

•(HF-)EPR on powder

• Inelastic Neutron Scattering

•Magnetometry on powder

•Specific heat on powder

•(HF-)EPR on single crystal

•Torque Magnetometry

•Angle resolved magnetometry

2

Page 3: Angle-resolved magnetometry for determination of magnetic …schnack/molmag/... · 2020. 7. 27. · Angle-resolved magnetometry for determination of magnetic anisotropy in low symmetry

Angular resolved magnetometry: the rotator

STMAn old technique

revisited thanks to the

automation & precision of

horizontal sample rotator

combined high sensitivity

of modern SQUID

magnetometers

H

Internal rod

External rod

Sample

holder

Wire &

spring

3

Page 4: Angle-resolved magnetometry for determination of magnetic …schnack/molmag/... · 2020. 7. 27. · Angle-resolved magnetometry for determination of magnetic anisotropy in low symmetry

H

Angular resolved magnetometry: the crystal

STM

0 -1 -1

0 -1 1

-1 0 1

• 1st step: Accurate indexing of the faces

2nd step: Three rotations along orthogonal

axes allow a full characterization of the

magnetic anisotropy without a priori

information

H

1°rot 2°rot 3°rot

?

4

Page 5: Angle-resolved magnetometry for determination of magnetic …schnack/molmag/... · 2020. 7. 27. · Angle-resolved magnetometry for determination of magnetic anisotropy in low symmetry

Angular resolved magnetometry: the support

STM

H H

1°rot 2°rot 3°rot

?

A teflon cube

x

y

z

5

Page 6: Angle-resolved magnetometry for determination of magnetic …schnack/molmag/... · 2020. 7. 27. · Angle-resolved magnetometry for determination of magnetic anisotropy in low symmetry

STM

SMM

The laboratory reference frame

By indexing with a single crystal X-ray diffractometer the

faces of the amorphous cube on which the crystal is

glued, the laboratory reference frame is defined in the

crystal lattice frame 6

Page 7: Angle-resolved magnetometry for determination of magnetic …schnack/molmag/... · 2020. 7. 27. · Angle-resolved magnetometry for determination of magnetic anisotropy in low symmetry

Angular resolved magnetometry: the support

STM

© On-cube indexing of poorly

defined or solvent loosing crystals7

Page 8: Angle-resolved magnetometry for determination of magnetic …schnack/molmag/... · 2020. 7. 27. · Angle-resolved magnetometry for determination of magnetic anisotropy in low symmetry

The sign of each rotation has to be carefully checked

H

Exte

rnal ro

d

Sam

ple

hold

er

Wire

&

sprin

g

Rotation

clockwise

from the

top

=

Increasing

angles for

QD

machines

Rotation clockwise

0° 90° 180° 270°

Rot x z y -z -y

Rot y z -x -z x

Rot z y x -y -x

Suggested sequences of rotations

Procedures to avoid mistakes

8

Page 9: Angle-resolved magnetometry for determination of magnetic …schnack/molmag/... · 2020. 7. 27. · Angle-resolved magnetometry for determination of magnetic anisotropy in low symmetry

Choose a right reference frame

for the cube and place the

crystal on +z

X rot–z cube’s face

on the support

x

zy

x

yz

x

zy

H//zH//y H//-z

0° 90° 180° 270°

x

y

z

H//-y0°

270°

y

zx

y

xz

y

zx

H//z H//-x H//-z y

xz

H//x0°

270°

z

yx

z

xy

z

yx

H//yH//x H//-y z

x

y

H//-x0°

270°

Y rot–z cube’s face

on the support

Z rot–y cube’s

face on the

support 9

Page 10: Angle-resolved magnetometry for determination of magnetic …schnack/molmag/... · 2020. 7. 27. · Angle-resolved magnetometry for determination of magnetic anisotropy in low symmetry

STM

SMM

Characterization of the magnetic anisotropy of Dy(hfac)3(NITR)2

10

Page 11: Angle-resolved magnetometry for determination of magnetic …schnack/molmag/... · 2020. 7. 27. · Angle-resolved magnetometry for determination of magnetic anisotropy in low symmetry

STM

SMM

Characterization of the magnetic anisotropy of Dy(hfac)3(NITR)2

Experimental data are simulated

assuming a simple tensorial relation

and taking into account that only the

component of M along H is measured

M H χ

2 2( ) ( cos ( ) 2 cos( )sin( ) sin ( ))M H

For each rotation :

Where , are the cyclic permutation of the reference frame axes

4.7599 0.3578 5.8439

0.3578 0.7758 0.4681

5.8439 0.4681 9.2236

χ

11

Page 12: Angle-resolved magnetometry for determination of magnetic …schnack/molmag/... · 2020. 7. 27. · Angle-resolved magnetometry for determination of magnetic anisotropy in low symmetry

STM

SMM

Characterization of the magnetic anisotropy of Dy(hfac)3(NITR)2

Diagonalization of the susceptibility matrix

' -1χ R χ R

Provides us with the principal values of the susceptibility:

4.7599 0.3578 5.8439

0.3578 0.7758 0.4681

5.8439 0.4681 9.2236

χ

x=0.2±0.1 emu·K·mol-1

y=1.3±0.1 emu·K·mol-1

z=13.2±0.2 emu·K·mol-1

The eigenvector matrix R

provides us with the principal

directions of the magnetic

anisotropy

12

Page 13: Angle-resolved magnetometry for determination of magnetic …schnack/molmag/... · 2020. 7. 27. · Angle-resolved magnetometry for determination of magnetic anisotropy in low symmetry

STM

SMM

Characterization of the magnetic anisotropy of Dy(hfac)3(NITR)2

Diagonalization of the susceptibility matrix

' -1χ R χ R

Provides us with the principal values of the susceptibility:

4.7599 0.3578 5.8439

0.3578 0.7758 0.4681

5.8439 0.4681 9.2236

χ

x=0.2±0.1 emu·K·mol-1

y=1.3±0.1 emu·K·mol-1

z=13.2±0.2 emu·K·mol-1

The eigenvector matrix R

provides us with the principal

directions of the magnetic

anisotropy

13

Page 14: Angle-resolved magnetometry for determination of magnetic …schnack/molmag/... · 2020. 7. 27. · Angle-resolved magnetometry for determination of magnetic anisotropy in low symmetry

STM

The non-linear case

The previous treatment to extract the susceptibility tensor

assumes that it is of second rank and that the

susceptibility does not depend on H

The last assumption is often not valid because of:

- saturation

- antiferromagnetic interactions overcome by

the magnetic field

A more complex analysis, no more model-free, is

necessary

A case study: a spin-canted Dy(III) Single Chain Magnet

14

Page 15: Angle-resolved magnetometry for determination of magnetic …schnack/molmag/... · 2020. 7. 27. · Angle-resolved magnetometry for determination of magnetic anisotropy in low symmetry

STM

SMM

Characterization of the magnetic anisotropy of Dy(hfac)3(NITR)2

•Magnetometry is NOT a LOCAL probe

•It averages over all the species in the crystal

•Triclinic crystals have one magnetically independent

site and are ideal candidates for this technique

•In monoclinic system b is a principal axis

•In orthorombic system a, b, and c are principal axes

15

Page 16: Angle-resolved magnetometry for determination of magnetic …schnack/molmag/... · 2020. 7. 27. · Angle-resolved magnetometry for determination of magnetic anisotropy in low symmetry

A noon triclinic case: the Cp*ErCOT SMM

Very air

sensitive !!

16

Page 17: Angle-resolved magnetometry for determination of magnetic …schnack/molmag/... · 2020. 7. 27. · Angle-resolved magnetometry for determination of magnetic anisotropy in low symmetry

The Cp*ErCOT case

17

Page 18: Angle-resolved magnetometry for determination of magnetic …schnack/molmag/... · 2020. 7. 27. · Angle-resolved magnetometry for determination of magnetic anisotropy in low symmetry

C18H23Er

Pnma

a = 10.2662(8)Å

b = 13.3052(13)Å

c = 11.8298(11)Å

Orthorhombic system:

2 orientations

Unit cell view Mirror planes //

to (ac) planeAlong b-axis view

Molecules lie on mirror planes

Angle between molecular pseudo-axis ~ 95°

The Cp*ErCOT case: an orthorombic crystal

18

Page 19: Angle-resolved magnetometry for determination of magnetic …schnack/molmag/... · 2020. 7. 27. · Angle-resolved magnetometry for determination of magnetic anisotropy in low symmetry

Difficult manipulation of the crystal in the glovebox:

Rotation 1 along 1= 0.614004a - 0.340304b + 0.712175c

The Cp*ErCOT case

0 50 100 150 200 250

0

1

2

3

4

5

/

em

u m

ol-1

/ °

2.000 3.000 4.000 5.000 6.000 7.000 8.000 10.00

T / K

19

Page 20: Angle-resolved magnetometry for determination of magnetic …schnack/molmag/... · 2020. 7. 27. · Angle-resolved magnetometry for determination of magnetic anisotropy in low symmetry

Difficult manipulation of the crystal in the glovebox:

Rotation 2: along 2= 0.317728a + 0.931653b + 0.176271c

The Cp*ErCOT case

T=10 K

20

Page 21: Angle-resolved magnetometry for determination of magnetic …schnack/molmag/... · 2020. 7. 27. · Angle-resolved magnetometry for determination of magnetic anisotropy in low symmetry

Simulation with two Ising contributions

Rotation 2: along 2= 0.317728a + 0.931653b + 0.176271c

The Cp*ErCOT case

T=10 K

0 50 100 150 200 250

0

1

2

3

4

5

6

7

measured contribute 1

simulation contribute 2

/ e

mu m

ol-1

/ °

This interpretation is not unique: how to verify it? 21

Page 22: Angle-resolved magnetometry for determination of magnetic …schnack/molmag/... · 2020. 7. 27. · Angle-resolved magnetometry for determination of magnetic anisotropy in low symmetry

The Cp*ErCOT case

Temperature dependence of the angular resolved magnetization

shows additional peaks at low temperature

Rotation 2: along 2= 0.317728a + 0.931653b + 0.176271c

22

Page 23: Angle-resolved magnetometry for determination of magnetic …schnack/molmag/... · 2020. 7. 27. · Angle-resolved magnetometry for determination of magnetic anisotropy in low symmetry

Out of equilibrium measurements

2500 s angle

50 s angle

At T=4 K the butterfly hysteresis of this SMM is open and

data are taken at different rotation rate of the field.

For long waiting time the sinusoidal behavior is restored

Rotation 2: = 0.001728a + 0.999571b - 0.029253c

23

Page 24: Angle-resolved magnetometry for determination of magnetic …schnack/molmag/... · 2020. 7. 27. · Angle-resolved magnetometry for determination of magnetic anisotropy in low symmetry

Out of equilibrium measurements

Simulation of out of equilibrium M

H is constant but changes, thus Meq changes with

Is the time elapsed between rotation and measurement

Best simulation obtained for:

With 0=105(5)s, A=0.210 s Oe -1 increasing fields

A=0.140 s Oe -1 decreasing fields 24

Page 25: Angle-resolved magnetometry for determination of magnetic …schnack/molmag/... · 2020. 7. 27. · Angle-resolved magnetometry for determination of magnetic anisotropy in low symmetry

Comparison with ab-initio estimation

Rotation data are

reproduced with two Ising

contributions but a problem

remains:

Who

Is

who

?

Ab initio

Theory

provides

the answer

ab initio calculation

fit of experimental data

ab inition calculation

fit of experimental data

25