AN ANALYTICAL AND EXPERIMENTAL STUDY ON …

8
AN ANALYTICAL AND EXPERIMENTAL STUDY ON REINFORCED CONCRETE BEAM WITH CARBON FIBER FABRIC WRAP ABHIJITH S 1* AND SENTHIL KUMAR G 2 1 M. Tech, structural engineering, Department of civil engineering, SRM university, kattankulathur, Chennai, Tamil Nadu, India 2 Professor, Civil Engineering Department, SRM University, Chennai, Tamil Nadu, India (Received 11 July, 2017; accepted 24 October, 2017) Key words: Critical load, Ultimate load, Flexural load, Shear stress, Deflection Jr. of Industrial Pollution Control 33(S3)(2017) pp 1370-1377 www.icontrolpollution.com Research Article *Corresponding authors email: abhijithsureshkarnikaram@gmail. com; senthilkumar. go@ktr. srmuniv. ac. in INTRODUCTION 1. To compare the difference in critical load, ultimate load and flexural strength of beam specimens retrofitted with carbon fiber fabric wrap (B u30, B u25, B u20 ) at different widths, i.e., 30 cm, 25 cm and 20 cm respectively. 2. To compare the experimental values of retrofitted beam specimens with conventional beam specimen’s (B conv ) test results. 3. To analyze the specimens tested experimentally in ANSYS software and to compare the analytical results with the experimental results. 4. To find the beam specimen with highest flexural strength and to compare its analytical values with the experimental values. 5. To check the shear stress distribution in the specimens using ANSYS software and find the maximum shear values of the specimens and the points at which shear concentration is higher. METHODOLOGY Use of carbon fiber based retrofitting sheets or mats have been in use for the past decade. Even though sufficient studies has to be carried out to optimize the cost involved in retrofitting since carbon fiber compounds are expensive. Carbon fiber fabric is abi- directional anisotropic compound. Retrofitting using carbon fiber fabric mat requires proper binding using epoxy resins. Epoxy resin plays a key role in the experiment by avoiding debonding failure during the experimental tests. The carbon fiber fabric as compared to carbon fiber woven sheets are very thin loosely arranged, minimum of five layer is required for adequate strength (Murali and Pannirselvam, 2011; Norris, et al., 1997; Antonopoulos and Triantafillou, 2002). In this study, carbon fiber fabric ABSTRACT Retrofitting materials like aluminum bars, steel laminates and glass fiber compounds has been used in the construction field for many decades. Carbon fiber compounds are the recent addition to the retrofitting materials. This study is a comparison of flexural and shear strength of a retrofitted beams with conventional beam. It also compares the experimental results with the analytical results. Analysis is done using the software ANSYS workbench. Carbon fiber fabric wraps are used for retrofitting test beams. Epoxy resin is used to bind the fabric to the beam in u – shaped wraps which binds the flexural face and the web of the beam. Total number of 4 beams of size (1500 × 200 × 250) mm including conventional beam is used for the experimental tests ( Two point loading). Difference in ultimate load, criticalload,flexural strength and shear strength are observed in experimental tests, and are being compare with analytical results. The beams were wrapped with five layers of carbon fiber fabric strips of different widths, 300 mm, 250 mm and 200 mm respectively. The highest flexural strength was observed in the two point load testing of beam retrofitted with 300 mm wide strips (BU30).

Transcript of AN ANALYTICAL AND EXPERIMENTAL STUDY ON …

Page 1: AN ANALYTICAL AND EXPERIMENTAL STUDY ON …

AN ANALYTICAL AND EXPERIMENTAL STUDY ON REINFORCED CONCRETE BEAM WITH CARBON FIBER FABRIC WRAP

ABHIJITH S1* AND SENTHIL KUMAR G2

1M. Tech, structural engineering, Department of civil engineering, SRM university, kattankulathur, Chennai, Tamil Nadu, India

2Professor, Civil Engineering Department, SRM University, Chennai, Tamil Nadu, India

(Received 11 July, 2017; accepted 24 October, 2017)

Key words: Critical load, Ultimate load, Flexural load, Shear stress, Deflection

Jr. of Industrial Pollution Control 33(S3)(2017) pp 1370-1377www.icontrolpollution.comResearch Article

*Corresponding authors email: abhijithsureshkarnikaram@gmail. com; senthilkumar. go@ktr. srmuniv. ac. in

INTRODUCTION 1. To compare the difference in critical load, ultimate

load and flexural strength of beam specimens retrofitted with carbon fiber fabric wrap (Bu30,Bu25, Bu20) at different widths, i.e., 30 cm, 25 cm and 20 cm respectively.

2. To compare the experimental values of retrofitted beam specimens with conventional beam specimen’s (Bconv) test results.

3. To analyze the specimens tested experimentally in ANSYS software and to compare the analytical results with the experimental results.

4. To find the beam specimen with highest flexural strength and to compare its analytical values with the experimental values.

5. To check the shear stress distribution in the specimens using ANSYS software and find the

maximum shear values of the specimens and the points at which shear concentration is higher.

METHODOLOGYUse of carbon fiber based retrofitting sheets or mats have been in use for the past decade. Even though sufficient studies has to be carried out to optimize the cost involved in retrofitting since carbon fiber compounds are expensive. Carbon fiber fabric is abi- directional anisotropic compound. Retrofitting using carbon fiber fabric mat requires proper binding using epoxy resins. Epoxy resin plays a key role in the experiment by avoiding debonding failure during the experimental tests. The carbon fiber fabric as compared to carbon fiber woven sheets are very thin loosely arranged, minimum of five layer is required for adequate strength (Murali and Pannirselvam, 2011; Norris, et al., 1997; Antonopoulos and Triantafillou, 2002). In this study, carbon fiber fabric

ABSTRACT

Retrofitting materials like aluminum bars, steel laminates and glass fiber compounds has been used in the construction field for many decades. Carbon fiber compounds are the recent addition to the retrofitting materials. This study is a comparison of flexural and shear strength of a retrofitted beams with conventional beam. It also compares the experimental results with the analytical results. Analysis is done using the software ANSYS workbench. Carbon fiber fabric wraps are used for retrofitting test beams. Epoxy resin is used to bind the fabric to the beam in u – shaped wraps which binds the flexural face and the web of the beam. Total number of 4 beams of size (1500 × 200 × 250) mm including conventional beam is used for the experimental tests ( Two point loading). Difference in ultimate load, criticalload,flexural strength and shear strength are observed in experimental tests, and are being compare with analytical results. The beams were wrapped with five layers of carbon fiber fabric strips of different widths, 300 mm, 250 mm and 200 mm respectively. The highest flexural strength was observed in the two point load testing of beam retrofitted with 300 mm wide strips (BU30).

Page 2: AN ANALYTICAL AND EXPERIMENTAL STUDY ON …

1371 ABHIJITH ET AL.

mats having three different widths [30, 25, 20] cm are u – wrapped constant intermediate gap of 10 cm to the beam specimens (Fig. 1).

MIX DESIGNThe specified strength of the concrete is 35 mpa in 28 days. The specific gravity of cement, coarse aggregate and fine aggregate are 3.15, 2.884 and 2.29 respectively. Grade of the cement used for the casting is opc 53. The water cement ratio adopted is 0.45. The mix proportion of the concrete has been obtained by the code [IS 10262-1982]. The mix

proportion obtained has been showed in Table 1.

The compression test of the concrete at 28 days has been carried out to check the average compressive strength of the concrete. The values obtained is as tabulated in the Table 2 and (Fig. 2). From the test results, the average compressive strength of the concrete is found to be 34.56 N/mm2.

EXPERIMENTAL STUDYTotal number of four beam specimens has been casted for the experimental studies. Beam specimens casted have been cured for 28 days before testing. Size of the beams are 1500 mm × 200 mm × 250 mm. Nomenclature of the beam specimens are as given in Table 3. Excellent bonding between the carbon fiber fabric mat and the surface of the beam specimen is required for the efficient increase in flexural strength of the specimen. Epoxyresin provides the adequate bonding strength to avoid debonding failure and the carbon fiber fabric mat act uniformly as the specimen under the loading condition (Fig. 3 and 4).

TESTING OF BEAM SPECIMENSAll the beam specimens are being tested under two point loading condition. The conventional beam (Bconv) is tested first to find out the critical and ultimate loads. The flexural strength is found out using the formula,

2

F Lb d

σ ×=

× (1)

Where σ is the flexural stress or the bending stress of the beam; F is the ultimate load exerted on the beam specimen; L is the effective length of the beam specimen; b is the breadth of the beam; d is the depth of the beam (Fig. 5).

Similarly, the retrofitted test beams, Bu30, Bu25, Bu20 are also tested respectively. The experimental test results of each beams which has been recorded are tabulated in Table 4. which is as follows:

EXPERIMENTAL TEST RESULTSThe experimental test results shows that there is an increase in the flexural stress or the bending stress as the width of the carbon fiber fabric wrap is increased. The load bearing capacity of the beam is increased as the width of the wrapping is increased. As compared

Fig. 1 Methodology flow chart.

Water (Liter) Cement (kg) Fine aggregate

(kg)Coarse aggregate

(kg)186 132 232.32 410.831.40 1 1.76 3.17

Table 1. Mix proportion

S. No Mould Number

Fresh Concrete Density in Kg

Hardened Concrete Density in Kg

Compressive Strength In N/Mm2

Avg.Compressive Strength in N/Mm2

1 CC 1 2666.66 2400 34.6 34.56

2 CC 2 2577.77 2429.63 36.13 CC 3 2607.41 2459.25 33

Table 2. Compression test results of concrete cubes (150 × 150) mm

Page 3: AN ANALYTICAL AND EXPERIMENTAL STUDY ON …

1372

AN ANALYTICAL AND EXPERIMENTAL STUDY ON REINFORCED CONCRETE BEAM WITH CARBON FIBER FABRIC WRAP

with the conventional beam, the percentage increase in flexural strength of BU20, BU25 and BU30 are 27.27%, 36. 36% and 54.55%.

The graphical representation of difference in ultimate load and flexural strength in test beams are showed in (Fig. 6 and Fig. 7) respectively (Yoganathan and Mahendran, 2014; Kharatmol, et al., 2014; Yasmeen, 2010).

The deflection at the right, left and the center portion

with the ultimate load of conventional beam, the percentage increase in BU20, BU25 and BU30 are 28.57%, 35.71% and 50% respectively. Similarly, as compared

Fig. 2 Compression test of cube specimen CC2.

Fig. 3 Cracks formed during the test of Bconv.

Fig. 4 Test setup of BU25.

Fig. 5 Test setup of BU30.

Fig. 6 Ultimate load chart of specimens.

Bconv Conventional beam

Bu20Beam wrapped with 200 mm wide strips at 100 mm spacing

Bu25Beam wrapped with 250 mm wide strips at 100 mm spacing

Bu30Beam wrapped with 300 mm wide strips at 100 mm spacing

Table 3. Nomenclature of test beam specimens

Specimen Critical load (KN)

Ultimate load (KN)

Flexural stress(KN/mm2)

Bconv 56 112 0.011Bu20 64 144 0.014Bu25 68 152 0.015Bu30 76 168 0.017

Table 4. Experimental test results

Fig. 7 Flexural strength of specimens.

Page 4: AN ANALYTICAL AND EXPERIMENTAL STUDY ON …

1373 ABHIJITH ET AL.

of the beam specimen is during two point loading is found out and tabulated using strain gauges. Since the procedure is a progressive loading the range of loading was adopted to be 4 KN (Venkatesha, et al., 2012). The load vs deflection graph is showed in the following figures (Fig. 8-11).

From the experimental test results, among the retrofitted test beams BU30 has the maximum deflection when BU20 has the minimum deflection. BU30 has the maximum ultimate load value while BU20 has the minimum ultimate load value (Table 5).

ANALYTICAL STUDYThe analytical part mainly consist of three stages, they are modeling, meshing and analysis. The modeling of the beam is carries out by creating the exact model of the test specimens. Meshing is the part where the choice of fine meshing or coarse meshing is made. This study is carried out under fine mesh condition. As the mesh gets finer the time taken for the analysis also increases.

Exact conditions where the experiments has been carried out is stimulated in ANSYS Workbench. The loads, Loading distances and support distances are provided exactly as the experimental setup. The physical and mechanical properties of the materials such as concrete, steel and carbon fiber is provided to the models.

Analytical Results of Specimens Loaded Under Ultimate Load of Conventional Beam

Analysis is done in two stages. First, by providing the ultimate load of conventional beam to the retrofitted beam in order to study the change in deformation and equivalent shear value in retrofitted beamsunder the ultimate load value condition of conventional beam. The analytical results under this condition is provided in Table 6.

As the results shows, the least deformation is showed by BU20 among retrofitted beam specimens as the maximum deformation is observed in BU30. The equivalent shear stress value is highest in BU25 as it is least in BU20 (Fig. 12-16).

Analytical Test Results of Specimens Tested Under Respective Ultimate Loads

The second stage of analysis is that the specimens are analyzed using the experimental values of their own. The results thus obtained has been tabulated in Table 7.

0

50

100

150

0 5 10 15

Load

(KN

)

Deflection (mm)

Load vs Deflection

Left

middle

Right

Fig. 8 Load vs. deflection graph of Bconv.

0

50

100

150

200

0 5 10

Load

(KN

)

Deflection (mm)

Load vs Deflection

Left

middle

Right

Fig. 9 Load vs. deflection graph of BU20.

0

50

100

150

200

0 2 4 6 8 10

Load

(KN

)

Deflection (mm)

Load vs Deflection

Left

middle

Right

Fig. 10 Load vs. deflection graph of BU25.

0

50

100

150

200

0 5 10

Load

(KN

)

Deflection (mm)

Load vs Deflection

Left

middle

Right

Fig. 11 Load vs. deflection graph of BU30.

Specimen Ultimate load (KN)

Maximum deflection (mm)

Bconv 112 9.92BU20 144 8.88BU25 152 9.18BU30 168 9.20

Table 5. Corresponding deflection under respective ultimate load of test beams

Page 5: AN ANALYTICAL AND EXPERIMENTAL STUDY ON …

1374

AN ANALYTICAL AND EXPERIMENTAL STUDY ON REINFORCED CONCRETE BEAM WITH CARBON FIBER FABRIC WRAP

Specimen Load(KN) Total deformation (mm) Equivalent stress (mpa)Bconv 112 0.662 113.56BU20 112 0.5209 110.34BU25 112 0.4955 329.63BU30 112 0.6095 105.52

Table 6. Change in deformation and equivalent shear value in retrofitted beams under the ultimate load value condition of conventional beam

Fig. 12 Bconv under loading.

Fig. 13 BU20 under ultimate load of conventional beam.

Here the least deformation among retrofitted test beams was observed in BU20 when the maximum deformation is found in BU30. The least equivalent

shear among retrofitted test beams was observed in BU20 where the maximum equivalent stress was observed in Bu25 (Fig. 17 and Fig. 18).

Page 6: AN ANALYTICAL AND EXPERIMENTAL STUDY ON …

1375 ABHIJITH ET AL.

Fig. 14 Bu25 under ultimate load of conventional beam.

Fig. 15 BU30 under ultimate load of conventional beam.

Fig. 16 BU20 under loading.

Page 7: AN ANALYTICAL AND EXPERIMENTAL STUDY ON …

1376

AN ANALYTICAL AND EXPERIMENTAL STUDY ON REINFORCED CONCRETE BEAM WITH CARBON FIBER FABRIC WRAP

Fig. 17 BU25 under loading.

Fig. 18 BU30 under loading.

CONCLUSIONBased on the experimental and analytical results the following conclusions has been made.

• The total deformation was highest for BU30 both in experimental as well as analytical results. Thus the beam wrapped with 300 mm wide strips has the largest deflection among the three retrofitted beams.

• Beam wrapped with 300m wide strips has the maximum flexural value (0.017 KN/mm2). While

the beam retrofitted with 20 mm wide strips has the least value for flexural stress (0.014 KN/mm2).

• The maximum equivalent stress value was observed in beam wrapped with 250 mm wide strips. While the least equivalent stress value was observed in beam retrofitted with 200 mm wide strips.

• The experimental values and the analytical values of deflectionhas slight variation. This might be caused by the quality of materials, quality of casting, errors occurred during testing.

Specimen Load (KN) Total Deformation (mm) Equivalent stress(mpa)Bconv 112 0.662 113.56BU20 114 0.669 142.5Bu25 152 0.672 447.36BU30 168 0.914 158.29

Table 7. Analytical test results of specimens tested under respective ultimate loads

Page 8: AN ANALYTICAL AND EXPERIMENTAL STUDY ON …

1377 ABHIJITH ET AL.

• As compared with the ultimate load of conventional beam, the percentage increase in BU20, BU25 and BU30 are 28.57%, 35.71% and 50% respectively. Similarly, as compared with the conventional beam, the percentage increase in flexural strength of BU20, BU25 and BU30 are 27.27%, 36.36% and 54.55%. Thus the most effective mode of retrofitting is clearly with 30 cm wide strips at 100 mm spacing.

This results are and conclusion is based on the experimental as well as analytical study of 4 beams. The air bubble or the void formed between the beam and the wrap is a phenomenon which cause variation in test results. Exact and 100% efficient bonding is not practically possible. This will cause variation in analytical and experimental results. Experiments with more number of beams can be done with more number of wrapping and varied width.

REFERENCESAntonopoulos, C.P. and Triantafillou, T.C. (2002).

Analysis of FRP-Strengthened RC Beam-Column Joints. Journal of Composites of Construction. 6 : 41-51.

Kharatmol, R., Pankaj, S., Rohit, T. and Raksha, J.K. (2014). Strengthening of Beams Using Carbon Fibre Reinforced Polymer. International Journal of

Emerging Engineering Research and Technology. 2 : 119-125.

Murali, G. and Pannirselvam, N. (2011). Flexural strengthening of reinforced concrete beams.

Norris, T., Saadatmanesh, H. and Ehsani, M.R. (1997). Shear and Flexural Strengthening of R/C Beams with Carbon Fiber Sheets. ASCE Journal of Structural. 123 : 903-911.

Using Fibre Reinforced Polymer Laminate: A review. APRN Journal of Engineering and Applied Science. 6 : 41-47.

Venkatesha, K.V., Dinesh, S.V., Balaji Rao, K., Bharatkumar, B.H., Balasubramanian, S.R. and Nagesh R.I. (2012). Experimental investigation of reinforced concrete beams with and without CFRP wrapping. Slovak Journal of Civil Engineering. 20(3) : 15-26.

Yasmeen, T.O. Structural Retrofitting of Reinforced Concrete Beams Using Carbon Fibre Reinforced Polymer. (2010). ISRN LUTVDG/TVSM. Lund university. 1-76.

Yoganathan, K.R. and Mahendran, N. (2014). Retrofitting of Geopolymer Beam Using Carbon Fibre Mat. International Journal of Innovative Research in Science, Engineering and Technology. 3 : 1251-1257.