ALLSPECIFICATIONSVALIDASOF02/20/2011 C7338COMBOTUB ·...

1
INSTALLATION: Add 1/2" to 1" height of tub at point K to allow space for bedding compound. All Watertech Whirlpool Baths require mortar to be placed under tub for tub bedding. Please measure tub before building tub cabinet. Drawing shows standard pump location for this tub. Custom pump locations available - please call Watertech Whirlpool Baths for details. Measurements are plus or minus 1/2", and are subject to change without notice. Filling this tub to the maximum may require an above average size or dedicated water heater. This data sheet supersedes all specifications published prior to this publication date. ALL SPECIFICATIONS VALID AS OF 02/20/2011 AND SUPERSEDES ALL PREVIOUS PUBLISHED DATA A C B D E F G Edge of tub to center of drain & overflow Inside width of tub floor at seating area Edge of tub to center of drain Total length of tub Total width of tub Inside length of tub at top Inside length of tub at floor H Edge of tub to center of overflow C7338 COMBO TUB 72" 58" C 36 3 / 4 " 15 7 / 8 " A B G 24" 22" 21" D J L K BASE RAIL L=72" W= 36 3/4" 13" F 18 1 / 2 " DRAIN O V E R F L O W OVERFLOW I OVERFLOW 4" I Bottom of overflow opening to bottom of base rail J K L Top of tub deck to tub floor at deepest point Bottom of tub lip to bottom of base rail Top of tub deck to bottom of base rail H 20 1 / 2 " 46" E SUCTION PUMP & BLOWER LOCATION

Transcript of ALLSPECIFICATIONSVALIDASOF02/20/2011 C7338COMBOTUB ·...

Page 1: ALLSPECIFICATIONSVALIDASOF02/20/2011 C7338COMBOTUB · INSTALLATION:Add1/2"to1"heightoftubatpointKtoallowspaceforbeddingcompound.AllWatertechWhirlpoolBathsrequire mortartobeplacedundertubfortubbedding

INSTALLATION:Add 1/2" to 1" height of tub at point K to allow space for bedding compound.All Watertech Whirlpool Baths requiremortar to be placed under tub for tub bedding. Please measure tub before building tub cabinet. Drawing shows standard pump locationfor this tub. Custom pump locations available - please call Watertech Whirlpool Baths for details. Measurements are plus or minus 1/2",and are subject to change without notice. Filling this tub to the maximum may require an above average size or dedicated water heater.

This data sheet supersedes all specifications published prior to this publication date.

ALL SPECIFICATIONS VALID AS OF 02/20/2011AND SUPERSEDESALLPREVIOUS PUBLISHED DATAA

CB

DEFG Edge of tub to center of drain & overflow

Inside width of tub floor at seating areaEdge of tub to center of drain

Total length of tubTotal width of tubInside length of tub at topInside length of tub at floor

H Edge of tub to center of overflow

C7338 COMBO TUB

72"

58" C

36 3/4"

15 7/8"

A

B

G

24"22"21"

D

J

LK

BASE RAIL

L=72" W= 36 3/4"

13" F

18 1/2"

D R A I N

OVERFLOW

OVERFLOWI

OVERFLOW

4"

I Bottom of overflow opening to bottom of base railJKL

Top of tub deck to tub floor at deepest pointBottom of tub lip to bottom of base railTop of tub deck to bottom of base rail

H

20 1/2"

46"

E

SUCTION

PUMP & BLOWERLOCATION