Initial (Per) Filter Cotton
Pro Anti LeakagePro Anti BacterialWaterproofLow resistanceElastic
Application and usage
Applicable to all kinds of ventilation equipment. dust removal equipment air supply system filtration
• Air conditioning and air ventilation system dust removal• All kinds of mechanical and electrical equlpment, machine room• High quality spraying system and pre filtration of air supply system in the baking room • Slice use, slice frame use, whole roll use
Technical index
Materials and features
• Using polyester fiber (PET) with elastic and anti-faulling. It is made by fusion process.• It is washable and can be reused afler spraying treatment, or the dust can be removed by
slapping and anti-blowing
Technical Parameters
Filter class:
G2 (EN779), EU2 (EUROVENT)
Filtration objects:
>5um Coarse dust and foreign objects
Average efficiency:
>75% (ASHRAE 52.1-1992)
Frame retardant grade:
Fl (DIN 53438), Bl (GB/T 17591-2006)
Final resistance:
250 Pa (recommended)
Dust holding capacity:
400g/m2
Moisture resistance (relative Humidity):
<10090RH
Resistant temperature:
<100°C
Instant temperature:
<120°C
Nominal Media Velocity (m/s)
1.3
1.5
Rated Air Flow(m3/h)
5400
4800
Initial Resistance(pa)
25
25
Final Resistance(pa)
250
260
Dust Holding Capacity(g/m2)
600
550
DimensionsHeight (m) Length (m) Thickness (mm)
1-2 50 20
1-2 50 18
1404
AIRP-X/EC
Mobile Air Purifying Units
STAGES OF FILTRATION
AIRP-X/EC air purifying units have been designed for mobility, purifying and cleaning air and eliminating odours , in areas
of .high occupancy where low noise and versatility are important
Ideal for Hospitals and other IndustriesLow Power EC Motor technology25MM Thickness Acoustic CasePlug & Play system with automatic controlUVc Germicidal Chamber4Stages of Filtration
ENERGY SAVING
The air inlet aperture has been designed to aid laminar air flow which, together with a dynamic pressure balancing chamber, helpsto optimise efficiency
The EC motor's high performance technology is a key element in reducing power consumption
DURABILITY
The outer panels of these units are made of pre-finished sheet metal with 40mm aluminium structural frames to maximise.the life of the equipment
EASE OF INSTALLATIONAND MAINTENANCE
The access door allows quick access to.clean the impeller and replace filters
LOW SOUND LEVEL
The 25mm thick noise reducing outer panels use bespoke, high quality insulating materials and make this ideal equipment for installation in areas where a low.noise level is required
> EURO
>' * * * * * Ventus
CONFIGURABLEFILTRATION STAGES
In addition to the odour eliminating activated carbon filter, the equipment has two intake pre-filters and one discharge filter, with a range of configurations, all giving the equipment an excellent.filtration performance
INTEGRATEDCONTROL SYSTEM
ON / OFF fan · Adjustable flow 65% - 100% · ON/OFF germicidal chamber · Time control · Control and alarm of dirty filters .Automatic operation ·
WASHABLEPRE-FILTER
The first pre-filter catches small, lint type particles, together with larger.particles and is dishwasher safe
GERMICIDAL CHAMBER
INTERMEDIATE FILTER
WASHABLE PRE-FILTER
INTEGRATED CONTROL
FINAL FILTER STAGE
WHEEL SET
ACTIVATED CARBON FILTER
GERMICIDAL CHAMBER
Depending on model, these purification units lcan be supplied with an integrated germicida
.chamber, using UV ultraviolet lamps “C” range
15
> EURO
>' * * * * * Ventus
Order code
Characteristics:• Framemadefrom40mmprofilealuminium.• Setofwheels.• Plug&Playsystemwithintegratedcontrol.• Controlanddirtyfiltersalarm.• Outerpanelsmadeof25mmthick,high
qualityacousticinsulation,andpre-finishedsheetmetal.
• Backwardcurvedimpeller.• Dishwashersafepre-filter.• Filtrationstages,dependingonmodel:
-F7+F9-F7+HEPAH14
• Activatedcarbonfilterforodourremoval.• Inspectioncoverformaintenanceandfilter
replacement.• GermicidalchamberwithUVc(256nm),
dependingonmodel.
Motor:• HighefficiencyE.C.technology,external
rotormotor,controllableby0-10Vsignal.• Singlephase200-240V–50/60Hzandthree
phase380-480V–50/60Hz.• Airtemperaturerangeof-25ºCto+60ºC.
Finish:• Aluminumprofileframeandpre-finished
sheetmetalwith25mmthickacousticallyinsulatedpanels.
AIRP-X/EC — 310 — F7+F9 — CG
Impellerdiameterinmm
Mobileairpurifyingunits
FilterF7+F9FilterF7+HEPAH14
1Recommendedeffectiveworkingareawitha3-meter-highpremises.2RadiatedsoundpressurelevelindB(A)at1.5mdistanceatmaximumflow.
Technical characteristics of the UVc germicidal chamberc
Technical characteristics
Dependingonmodel,thesepurificationunitscanbesuppliedwithanintegralgermicidalchamber,usingUVultravioletlamps“C”inaspectrumof256nm,indicatedwaveamplitude,toinactivateawidevarietyofmicroorganismsbyabsorbingshortwavelengthenergythroughDNAandRNA.Forspecifictypesofvirusesorbacteriathatareaffectedbytheradiationdoseinthegermicidalchamber,consultthespecificdocument.
UVcgermicidalchamber
*MinimumdosecalculatedbasedonflowwithF7+H14filters.
AIRP-X/EC-310 6 66 16,8 5,9
AIRP-X/EC-400 4 100 28 5,6
AIRP-X/EC-500 6 150 42 4,5
Model Number of lamps
Total electrical power
(W)
Total UVc radiation
power (W)
Radiation dose*
(mJ/cm2)
Model Recommended effective working area1 (m2) Speed Power Power supply
Sound pressure
max speedlevel at 50% of
2
Maximum flow 3
rate (m /h) Weight
Filters (F7+F9)
Filters (F7+H14) (r/min) (W) dB(A) Filters
(F7+F9)Filters
(F7+H14) (kg)
AIRP-X/EC-310 140 50 1920 175 200-240V50/60Hz1Ph 29 1450 510 55
AIRP-X/EC-400 220 130 1550 460 200-240V50/60Hz1Ph 38 2200 1300 97
AIRP-X/EC-500 300 325 1250 1150 380-480V50/60Hz3Ph 36 2990 3250 165
Filters EN 779Em EN 1822
ISO 16890ISO
ePM1
ISO ePM2,5
ISO ePM10
ISOCOARCE
G4 90% - - - - >90%F7 90% - >50% >65-95% >85% -F9 95% - >80% >95% >95% -HEPAH14 - >99,995% - - - -
Filter characteristics
16
Ji. EURO
>' * * * * * Ventus
17
AIRP-X/EC-310 542 500 960
AIRP-X/EC-400 742 700 1210
AIRP-X/EC-500 942 900 1550
Model A (mm)
B(mm)
H(mm)
*Datasubjecttochangewithoutpriornotice.
Acoustic parameters
AIRP-X/EC-310 30 44 33 32 44 25 24 19AIRP-X/EC-400 37 52 41 42 34 29 27 27AIRP-X/EC-500 30 42 45 50 50 50 47 41
Model 63 125 250 500 1000 2000 4000 8000
Sound power spectrum Lw (A) in dB (A) per frequency band in Hz. Values are at maximum speed and average flow.
Dimensions mm
AB
H