AIRP-X/EC Initial (Per) Filter Cotton€¦ · AIRP-X/EC — 310 — F7+F9 — CG Impeller diameter...

4
14 AIRP-X/EC Mobile Air Purifying Units STAGES OF FILTRATION AIRP-X/EC air purifying units have been designed for mobility, purifying and cleaning air and eliminating odours , in areas of .high occupancy where low noise and versatility are important Ideal for Hospitals and other Industries Low Power EC Motor technology 25MM Thickness Acoustic Case Plug & Play system with automatic control UVc Germicidal Chamber 4Stages of Filtration ENERGY SAVING The air inlet aperture has been designed to aid laminar air flow which, together with a dynamic pressure balancing chamber, helps to optimise efficiency The EC motor's high performance technology is a key element in reducing power consumption DURABILITY The outer panels of these units are made of pre-finished sheet metal with 40mm aluminium structural frames to maximise .the life of the equipment EASE OF INSTALLATION AND MAINTENANCE The access door allows quick access to .clean the impeller and replace filters LOW SOUND LEVEL The 25mm thick noise reducing outer panels use bespoke, high quality insulating materials and make this ideal equipment for installation in areas where a low .noise level is required

Transcript of AIRP-X/EC Initial (Per) Filter Cotton€¦ · AIRP-X/EC — 310 — F7+F9 — CG Impeller diameter...

Page 1: AIRP-X/EC Initial (Per) Filter Cotton€¦ · AIRP-X/EC — 310 — F7+F9 — CG Impeller diameter in mm Mobile air purifying units Filter F7 + F9 Filter F7 + HEPA H14 1 Recommended

Initial (Per) Filter Cotton

Pro Anti LeakagePro Anti BacterialWaterproofLow resistanceElastic

Application and usage

Applicable to all kinds of ventilation equipment. dust removal equipment air supply system filtration

• Air conditioning and air ventilation system dust removal• All kinds of mechanical and electrical equlpment, machine room• High quality spraying system and pre filtration of air supply system in the baking room • Slice use, slice frame use, whole roll use

Technical index

Materials and features

• Using polyester fiber (PET) with elastic and anti-faulling. It is made by fusion process.• It is washable and can be reused afler spraying treatment, or the dust can be removed by

slapping and anti-blowing

Technical Parameters

Filter class:

G2 (EN779), EU2 (EUROVENT)

Filtration objects:

>5um Coarse dust and foreign objects

Average efficiency:

>75% (ASHRAE 52.1-1992)

Frame retardant grade:

Fl (DIN 53438), Bl (GB/T 17591-2006)

Final resistance:

250 Pa (recommended)

Dust holding capacity:

400g/m2

Moisture resistance (relative Humidity):

<10090RH

Resistant temperature:

<100°C

Instant temperature:

<120°C

Nominal Media Velocity (m/s)

1.3

1.5

Rated Air Flow(m3/h)

5400

4800

Initial Resistance(pa)

25

25

Final Resistance(pa)

250

260

Dust Holding Capacity(g/m2)

600

550

DimensionsHeight (m) Length (m) Thickness (mm)

1-2 50 20

1-2 50 18

1404

AIRP-X/EC

Mobile Air Purifying Units

STAGES OF FILTRATION

AIRP-X/EC air purifying units have been designed for mobility, purifying and cleaning air and eliminating odours , in areas

of .high occupancy where low noise and versatility are important

Ideal for Hospitals and other IndustriesLow Power EC Motor technology25MM Thickness Acoustic CasePlug & Play system with automatic controlUVc Germicidal Chamber4Stages of Filtration

ENERGY SAVING

The air inlet aperture has been designed to aid laminar air flow which, together with a dynamic pressure balancing chamber, helpsto optimise efficiency

The EC motor's high performance technology is a key element in reducing power consumption

DURABILITY

The outer panels of these units are made of pre-finished sheet metal with 40mm aluminium structural frames to maximise.the life of the equipment

EASE OF INSTALLATIONAND MAINTENANCE

The access door allows quick access to.clean the impeller and replace filters

LOW SOUND LEVEL

The 25mm thick noise reducing outer panels use bespoke, high quality insulating materials and make this ideal equipment for installation in areas where a low.noise level is required

Page 2: AIRP-X/EC Initial (Per) Filter Cotton€¦ · AIRP-X/EC — 310 — F7+F9 — CG Impeller diameter in mm Mobile air purifying units Filter F7 + F9 Filter F7 + HEPA H14 1 Recommended

> EURO

>' * * * * * Ventus

CONFIGURABLEFILTRATION STAGES

In addition to the odour eliminating activated carbon filter, the equipment has two intake pre-filters and one discharge filter, with a range of configurations, all giving the equipment an excellent.filtration performance

INTEGRATEDCONTROL SYSTEM

ON / OFF fan · Adjustable flow 65% - 100% · ON/OFF germicidal chamber · Time control · Control and alarm of dirty filters .Automatic operation ·

WASHABLEPRE-FILTER

The first pre-filter catches small, lint type particles, together with larger.particles and is dishwasher safe

GERMICIDAL CHAMBER

INTERMEDIATE FILTER

WASHABLE PRE-FILTER

INTEGRATED CONTROL

FINAL FILTER STAGE

WHEEL SET

ACTIVATED CARBON FILTER

GERMICIDAL CHAMBER

Depending on model, these purification units lcan be supplied with an integrated germicida

.chamber, using UV ultraviolet lamps “C” range

15

Page 3: AIRP-X/EC Initial (Per) Filter Cotton€¦ · AIRP-X/EC — 310 — F7+F9 — CG Impeller diameter in mm Mobile air purifying units Filter F7 + F9 Filter F7 + HEPA H14 1 Recommended

> EURO

>' * * * * * Ventus

Order code

Characteristics:• Framemadefrom40mmprofilealuminium.• Setofwheels.• Plug&Playsystemwithintegratedcontrol.• Controlanddirtyfiltersalarm.• Outerpanelsmadeof25mmthick,high

qualityacousticinsulation,andpre-finishedsheetmetal.

• Backwardcurvedimpeller.• Dishwashersafepre-filter.• Filtrationstages,dependingonmodel:

-F7+F9-F7+HEPAH14

• Activatedcarbonfilterforodourremoval.• Inspectioncoverformaintenanceandfilter

replacement.• GermicidalchamberwithUVc(256nm),

dependingonmodel.

Motor:• HighefficiencyE.C.technology,external

rotormotor,controllableby0-10Vsignal.• Singlephase200-240V–50/60Hzandthree

phase380-480V–50/60Hz.• Airtemperaturerangeof-25ºCto+60ºC.

Finish:• Aluminumprofileframeandpre-finished

sheetmetalwith25mmthickacousticallyinsulatedpanels.

AIRP-X/EC — 310 — F7+F9 — CG

Impellerdiameterinmm

Mobileairpurifyingunits

FilterF7+F9FilterF7+HEPAH14

1Recommendedeffectiveworkingareawitha3-meter-highpremises.2RadiatedsoundpressurelevelindB(A)at1.5mdistanceatmaximumflow.

Technical characteristics of the UVc germicidal chamberc

Technical characteristics

Dependingonmodel,thesepurificationunitscanbesuppliedwithanintegralgermicidalchamber,usingUVultravioletlamps“C”inaspectrumof256nm,indicatedwaveamplitude,toinactivateawidevarietyofmicroorganismsbyabsorbingshortwavelengthenergythroughDNAandRNA.Forspecifictypesofvirusesorbacteriathatareaffectedbytheradiationdoseinthegermicidalchamber,consultthespecificdocument.

UVcgermicidalchamber

*MinimumdosecalculatedbasedonflowwithF7+H14filters.

AIRP-X/EC-310 6 66 16,8 5,9

AIRP-X/EC-400 4 100 28 5,6

AIRP-X/EC-500 6 150 42 4,5

Model Number of lamps

Total electrical power

(W)

Total UVc radiation

power (W)

Radiation dose*

(mJ/cm2)

Model Recommended effective working area1 (m2) Speed Power Power supply

Sound pressure

max speedlevel at 50% of

2

Maximum flow 3

rate (m /h) Weight

Filters (F7+F9)

Filters (F7+H14) (r/min) (W) dB(A) Filters

(F7+F9)Filters

(F7+H14) (kg)

AIRP-X/EC-310 140 50 1920 175 200-240V50/60Hz1Ph 29 1450 510 55

AIRP-X/EC-400 220 130 1550 460 200-240V50/60Hz1Ph 38 2200 1300 97

AIRP-X/EC-500 300 325 1250 1150 380-480V50/60Hz3Ph 36 2990 3250 165

Filters EN 779Em EN 1822

ISO 16890ISO

ePM1

ISO ePM2,5

ISO ePM10

ISOCOARCE

G4 90% - - - - >90%F7 90% - >50% >65-95% >85% -F9 95% - >80% >95% >95% -HEPAH14 - >99,995% - - - -

Filter characteristics

16

Page 4: AIRP-X/EC Initial (Per) Filter Cotton€¦ · AIRP-X/EC — 310 — F7+F9 — CG Impeller diameter in mm Mobile air purifying units Filter F7 + F9 Filter F7 + HEPA H14 1 Recommended

Ji. EURO

>' * * * * * Ventus

17

AIRP-X/EC-310 542 500 960

AIRP-X/EC-400 742 700 1210

AIRP-X/EC-500 942 900 1550

Model A (mm)

B(mm)

H(mm)

*Datasubjecttochangewithoutpriornotice.

Acoustic parameters

AIRP-X/EC-310 30 44 33 32 44 25 24 19AIRP-X/EC-400 37 52 41 42 34 29 27 27AIRP-X/EC-500 30 42 45 50 50 50 47 41

Model 63 125 250 500 1000 2000 4000 8000

Sound power spectrum Lw (A) in dB (A) per frequency band in Hz. Values are at maximum speed and average flow.

Dimensions mm

AB

H