Air purification tech that pays
description
Transcript of Air purification tech that pays
Air purification tech that pays
Clean Air indoors
Air purification tech that pays
healthy climate smart
cost efficient
Clean Air indoors
healthy
climate smart
cost efficient
A sound living environment is:
Our air purification technologycontributes to a sound living environment
Clean Air? hälsosam
+ small but health affecting amounts of particles, gases och microbes…
Argon 0,93%
Carbon dioxide 0,04%
Oxygen 20,95%
Nitrogen 78,08%
Clean Air? healthy
1 nm 10 nm 100 nm 1 m 10 m 100 m size
SMOKE, SOOT, ASHES…
DUST
VIRUS BACTERIA
POLLENSVOC, GASES SOLVENTS
WARNING: Capture by lungs!
Conventional filters
Air Ionic air purification technology
Small particles Organic compounds Chemicals Bacteriae VirusSpores
Tiredness Irritated breathing/eyes Allergies AsthmaIllness
healthy
Clean Air?
Small particles Organic compounds Chemicals Bacteriae VirusSpores
Alertness Zeal Better sleep Improved health
healthy
Clean Air!
Climate SmartReduced energy consumptionReduced dimensions of vent ducts and fans Less CO2 emission
Less waste of limited resources
climate smart
Increased recirculation of indoor airHeat exchangers redundantLower pressure drop
Reduced energy costs
Less heatingLess electricityLess cooling
…and less noisy
cost efficient
Lower Cost of BuildingSmaller vent ductsNo heat exchangers Smaller fans
Reduced investment when building
cost efficient
Natural air cleaning process:• Rain, waterfalls• Shoreline• Thunderstorms • UV-light • Radioactive background radiation, cosmic radiation
Can be replicated:heating, radioactive radiation, electric discharge…
Air Ionization technology
Sharp-point Ionization
High voltage DC
The sharp-point ionizer generates large volumes of primary ions which attract and combine with water molecules forming cluster ions.
technology
O2-
O2-(H2O)n…
Cluster ions attach to and charge small particles which in turn attach to each other, gradually forming larger particles
Oxygen ions attract water molecules, forming cluster (hydrate) ions
nm…
m…
High concentrationof primary oxygen ions
technology
Sharp-point Ionization
Filtering
Particulate matter in the size range of m and larger are captured by the filter because of size and electrostatic charge. The filter can be either a passive PPXTM-filter or an electrostatic filter.
technology
DBD Ionization
The DBD (dielectric barrier discharge) ionizer generates a balanced mix of negative and positive primary ions.
technology
DBD Ionization
H+(H2O)n, O2-(H2O)m…
O2-
O2+N2
+
nm…
m…
High concentration of negative and positive primary ions …
These primary ions attract water molecules, forming various cluster (hydrate) ions
Properly mixed these cluster ions interact to form reactive oxygen species which breaks down many volatile organic and chemical substances and microbs
O2•-, OH-, •OH…
technology
An Efficient Combination
Re-circulation of clean air
CLEAN AIR
DIRTY AIR
Sharp-point Ionizer
FilterDBD Ionizer
technology
Control
Recirculation & Control technology
DUC
Ion-/ VOC-sensor
Sharp-point Ionizer Filter DBD Ionizer ( Extra Ionizer )
Dampers
Remote Control via Internet
CO2-sensor
technology
Recirculation & Control
0102030405060708090
100
0,5 0,75 1 1,5 2 2,5 3
It Works!
Filtering of airborne particles in different sizes, ref: Indoor Air 2008; 18: 106–112
Cleaning efficiency [%]
Particle diameter [m]
Ionization + filter
Filter
technology
Ref: Indoor Air 2008; 18: 106–112
Cleaning efficiency [%]
Bakterier:
technology
It Works!
0
10
20
30
40
50
60
70
80
Filter Filter + Ionization
B.SubtilisE.Coli
Bacteriae
Ref: Dr. Stacy L. Daniels: On the Ionization of Air for Removal of Noxious Effluvia, IEEE Transactions on Plasma Science, vol. 30, No. 4, August 2002
”CHEMICAL COMPOUNDS AMENABLE TOTREATMENT BY AIR IONIZATION”
Namn Formel Namn Formel Namn Formel
Phenanthrene C14H10 Cyclohexane C6H12 Methylene Chloride CH2Cl2
α-Pinene C8H19 n-Butyl Acetate C8H12O2 Tetrachloromethane CCl4
Naphatlene C10H8 n-Heptane C7H16 Ethane C2H6
1,2,4-Trimethylbenzene C9H12 Ammonia NH3 Nitric Acid HNO3
Limonene C10H16 n-Hexane C8H14 CFC-113 C2Cl3F3
p-Xylene C8H10 Acetaldehyde CH3CHO CFC-12 CCl2F2
Styrene C8H8 Methyl Acetat C3H6O2 Oxygen O2
o-, m-Xylene C8H10 n-Pentane C5H12 Methyl Cyanide C2H3N
Ethyl Benzene C8H10 Hydrogen Sulfide H2S Sulfur Dioxide O2S
Toluene C7H8 Ethyl Alcohol C2H5OH Sulfuric Acid H2SO4
Cyclohexene C6H10 Ethylene C2H4 Ozone O3
Chlorobenzene C6H5Cl Butane C4H10 Methane CH4
Benzene C6H6 Methyl Alcohol CH4O Water H2O
Nitric Oxide NO Formaldehyde CH2O Hydrogen Chloride HCl
Tetrachloroethylene C2Cl4 1,1,1-Trichloroethane C2H3Cl3 Nitrous Oxide N2O
Trichloroethylene C2HCl3 1,1,2-Trichloroethane C2H3Cl3 Hexaflouroethane C2F6
Methyl Ethyl Ketone C4H8O Carbonyl Sulfide COS Hydrogen Cyanide HCN
Nitrogen Dioxide NO2 Phosgene COCl2 Carbon Dioxide CO2
1,2-Dichloroethylene C2H2Cl2 Halon FC 12-B CClBrF2 Carbon Monoxide CO
Octane C8H18 Methyl Chloride CH3Cl Nitrogen N2
technology
Example: C10H8 + 12 O2 → 10 CO2 + 4 H2O
It Works!
DimensioningAddition of fresh: 5 l/s (18 m3/h) per person air, (min.) 0,35 l/s (1,3 m3/h), per m2 yta
Re-circulation: Up to 80% return air CO2 level checked by sensor
Air cleaning capacity: APS-7: 7000 m3/h (6 DBD-tubes, 12 sharp point
brushes)
Ion concentration: 1500 – 3000 ions/cm3 (Outdoor air: 300 joner/cm3),
technology
Desired particle Count? technology
"Rumsluft"293 0008 320 00035 200 000ISO 9
Klass 100 00029 300832 0003 520 000ISO 8
Klass 10 0002 93083 200352 000ISO 7
Klass 10002938 32035 200102 000237 0001 000 000ISO 6
Klass 100298323 52010 20023 700100 000ISO 5
Klass 10833521 0202 37010 000ISO 4
Klass 18351022371 000ISO 3
41024100ISO 2
210ISO 1
5 m1 m0,5 m0,3 m0,2 m0,1 m
Maximala koncentrationsgränser för partiklar lika stora eller större än:Federal
Standard 209E
KLASSGRÄNSER [Antal partiklar/m3]ISO 14644-1
ISO 14644-1 Renrumsklassificering
"Rumsluft"293 0008 320 00035 200 000ISO 9
Klass 100 00029 300832 0003 520 000ISO 8
Klass 10 0002 93083 200352 000ISO 7
Klass 10002938 32035 200102 000237 0001 000 000ISO 6
Klass 100298323 52010 20023 700100 000ISO 5
Klass 10833521 0202 37010 000ISO 4
Klass 18351022371 000ISO 3
41024100ISO 2
210ISO 1
5 m1 m0,5 m0,3 m0,2 m0,1 m
Maximum concentration limits for particulate matter in sizes larger than:Federal
Standard 209E
[ No. of particles/m3 ]ISO 14644-1
ISO 14644-1 Clean Room Classification
Desired Ion Count?Russian standard: “Requirements for air ions content of housings where PCs and VDTs are used”:
Ions per cm3 N+ [/cm3] N- [/cm3]
Minimum allowance 400 600
Optimum 1500 - 3000 3000 - 5000
Maximum allowable 50 000 50 000
technology
Ozone?No, our air purification technology producesno* or very little ozone.
Arbetsmiljöverket (Swedish Work Environment Authority): ”The limit value for ozone exposure during one work day (8 hours) is 100 ppb. The limit value for 15 minutes of exposure is 300 ppb.” We’re not even close.
* Detectable with advanced equipment only.
technology
Carbon Dioxide?Not harmful other than in high concentrations but often used as an indicator of other pollutants
Average concentration in athmosphere: 400 ppm
Limit (as indicator, AFS 2009:2): <1000 ppm
Limit (as pollutant, AFS 2005:17): <5000 ppm
Security: A CO2-”guard” connected to a fresh air damper quickliy reduces the CO2-level when the desired limit is reached.
technology
Carbon filters?Carbon-/HEPA-filter are efficient but generate a high pressure drop, are expensive and need to replaced often.
Our technology is equally efficient, makes it possible to re-circulate air and costs far less in the long run.
technology
Heat Exchangers?Substantial investment
Need a lot of maintenance in order not to lose efficiency and spread odour…
technology
Applications
Air Ionic provide efficient solutions for most needs…
schools hospitals industry
workshops offices livestock farming
applications
Product RangeAir Purification Systems DBD Ionizers Particle Separators
Air Purification Modules Electrostatic Filters Stand-Alone Air Cleaners
products
APS Air Purification SystemsBuilt into new or existent HVAC (ventilation) system
Complete with particle separator, DBD Ionizers, return air damper and control system
Scaleable – easy to dimension, install and maintain
Dimensioned after duct size, air quality and air flow:APS-7 < 7000 m3/hAPS-14 < 14 000 m3/hAPS-21 < 21 000 m3/hAPS…
products
RJA-6 DBD IonizerDBD Ionizer featuring six individually powered DBD tubes
Usually part of an APS air cleaning system
Suitable for an air flow of up to 7000 m3/h under normal conditions
products
APU-SF Particle SeparatorSharp-point Ionizer and filter
Depending on application, either PPXTM-filters or elctrostatic filters can be used
Usually part of an APS air cleaning system
Flexible dimensioning and installation – adapted after duct size, air quality and air flow
products
APM Air Cleaning ModuleCompact air cleaning module suitable for smaller HVAC systems
Complete with particle separator and DBD Ionizers
Capacity: APM-1: < 200 m3/hAPM-2: < 650 m3/hAPM-3: < 2000 m3/h
products
EFX Electrostatic FiltersElectrostatic filters with pre-ionization
Module-based system designed to replace conventional filters with a minimum of adaptive work
May be part of an APS system
Suitable for air flows > 500 m3/h
products
APU-SA Stand-Alone Air CleanerStand-alone particle separator
Compact and silent
Designed for office premises and similar
Maximum capacity: 400 m3 air/h
products
Simply a great deal: FEATURES BENEFITS VALUE !
Fewer airborne particles, VOCs and microbes
Improved alertness/ health
Higher working capacity
Reduced sick leave
Increased recirculation of indoor air
Reduced need for heating/cooling, (Heat exchanger redundant)
Reduced energy costs
Reduced need for investments
Less stress on environment
Less noise
Lower air flow and pressure drop in ventilation system
Down-sizing of ventilation system (reduces gauge, fan power…)
summary
Air purification tech that pays
That you for you time!Air Ionic ABKrokslätts fabriker 30SE-431 37 MölndalSweden
+46 31 706 36 49www.airionic.se