Agilent GC catalog .pdf

753
T abl e of Contents Sales, Service, and Support 3–7  T e c hn ic al S u pp or t Inform atio n . . . . . . . . . . . . . . . . 3 Serv ic e sI n fo rmation . . . . . . . . . . . . . . . . . . . . . 4 –5 Training Information . . . . . . . . . . . . . . . . . . . . . . . . 4 Agilent Offices . . . . . . . . . . . . . . . . . . . . . . . . . .6–7 F eatured Pr oducts 9  General Chr omatogr aphy 11109  Vial s , Cap sand Se p ta . . . . . . . . . . . . . . . . . .12 –38 St andards . . . . . . . . . . . . . . . . . . . . . . . . . . 9 2 –1 0 1 Syringes. . . . . . . . . . . . . . . . . . . . . . . . . . . . .39–46 Integrators, Integrator Suppliesand Cables . .102–106 Ga sM an ag e m e nt . . . . . . . . . . . . . . . . . . . . .47–82 Books , Le arn ing So ftware andCDs . . . . . .10 7–109 Ha rd w ar e . . . . . . . . . . . . . . . . . . . . . . . . . . .83 –91 Sample Preparation 111–147  So lid Ph as e Extraction ( SPE) . . . . . . . . . . . 111–131 Com biZo rb Sc av en ge rs . . . . . . . . . . . . . . .139 –141 M an ifoldsand Acc es s or ies . . . . . . . . . . . . 13 2–13 8 Sa m p le F iltr at ion . . . . . . . . . . . . . . . . . . . . 14 2 –14 7 GC and GC/ MS 149–441  GC Supplies . . . . . . . . . . . . . . . . . . . . . . . . 149–168 GC an d GC/M S Co lum n s . . . . . . . . . . . . . . 21 7–3 23 GC I ns tru me nt Par tsan d S up plies . . . . . . .16 9–198 Tr ou ble s ho oting /M ainte nanc e . . . . . . . . . .324 –340 GC/M S Pa rtsan d S u p p lies. . . . . . . . . . . . .19 9–2 16 Applications . . . . . . . . . . . . . . . . . . . . . . . . 341–441 LC and LC / MS 443–652  LC Supplies . . . . . . . . . . . . . . . . . . . . . . . . 443–456 LC a n d L C/M S Co lu m n s . . . . . . . . . . . . . . . 50 1–5 99 LC Instrument Partsand Supplies . . . . . . . . 457–500 Tr ou ble s ho oting /M ainte nanc e . . . . . . . . . .600 –603 LC/M S Pa rtsan d S u p pl ies . . . . . . . . . . . . .48 3–4 84 Applications . . . . . . . . . . . . . . . . . . . . . . . . 604–652 CE and CE / MS 653–668  CE Supplies . . . . . . . . . . . . . . . . . . . . . . . . 653–654 Capillaries . . . . . . . . . . . . . . . . . . . . . . . . .660–666 CE Instrument Partsand Supplies . . . . . . . . . . . . 655 Solu tio n Kits . . . . . . . . . . . . . . . . . . . . . . .666–6 6 8 CE/M S Ins trum en t Partsand Sup plies . . . . 65 6–659 I C P - M S 669690  75 00ICP-MS Su pplies. . . . . . . . . . . . . . . . 669 –67 8 ICP-M S S ta nd ar ds . . . . . . . . . . . . . . . . . . .68 9 –690 45 00ICP-MS Su pp lies. . . . . . . . . . . . . . . . 679 –68 8 UV-V i s 691–699  Cellsand Cell Supplies . . . . . . . . . . . . . . . . 691–694 Di s s olution T es ting Su pp lies . . . . . . . . . . . . . . . . 69 8 Tubing and Fittings . . . . . . . . . . . . . . . . . . . . . . . 695 Che mic al Standar dsand Acc es s oryKits . . . . . . .69 9 Spe c trop ho tom eter Su pp lies . . . . . . . . . . .69 6–697 I ndi ces 700– 744 Alp habe tic al . . . . . . . . . . . . . . . . . . . . . . .7 01–707 Par t Nu m b e r . . . . . . . . . . . . . . . . . . . . . . .72 0 –744 Compound . . . . . . . . . . . . . . . . . . . . . . . . . 708–719 O rdering Inf ormation 745–752  EasyOrdering Termsand Conditions . . . . . . 745–746 E as yWa y sto Ord er . . . . . . . . . . . . . . . . . .74 8–7 49 Cus tomColu m n Ord er s . . . . . . . . . . . . . . .746 –748 Ord e r F o rm s . . . . . . . . . . . . . . . . . . . . . . .75 0 –752

Transcript of Agilent GC catalog .pdf

  • 8/14/2019 Agilent GC catalog .pdf

    1/750

    Table of ContentsSales, Service, and Support 37 Technical Support Information . . . . . . . . . . . . . . . .3 ServicesInformation . . . . . . . . . . . . . . . . . . . . .45Training Information . . . . . . . . . . . . . . . . . . . . . . . .4 Agilent Offices . . . . . . . . . . . . . . . . . . . . . . . . . .67

    Featured Products 9

    General Chromatography 11109 Vials, Capsand Septa . . . . . . . . . . . . . . . . . .1238 Standards . . . . . . . . . . . . . . . . . . . . . . . . . .92101Syringes. . . . . . . . . . . . . . . . . . . . . . . . . . . . .3946 Integrators, Integrator Suppliesand Cables . .102106GasM anagement . . . . . . . . . . . . . . . . . . . . .4782 Books, Learning Software and CDs . . . . . .107109Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . .8391

    Sample Preparation 111147 Solid Phase Extraction (SPE) . . . . . . . . . . .111131 CombiZorb Scavengers . . . . . . . . . . . . . . .139141M anifoldsand Accessories . . . . . . . . . . . .132138 Sample Filtration . . . . . . . . . . . . . . . . . . . .142147

    GC and GC/ MS 149441 GC Supplies . . . . . . . . . . . . . . . . . . . . . . . .149168 GC and GC/M S Columns . . . . . . . . . . . . . .217323GC Instrument Partsand Supplies . . . . . . .169198 Troubleshooting/M aintenance . . . . . . . . . .324340GC/M S Partsand Supplies . . . . . . . . . . . . .199216 Applications . . . . . . . . . . . . . . . . . . . . . . . .341441

    LC and LC/ MS 443652 LC Supplies . . . . . . . . . . . . . . . . . . . . . . . .443456 LC and LC/M S Columns . . . . . . . . . . . . . . .501599LC Instrument Partsand Supplies . . . . . . . .457500 Troubleshooting/M aintenance . . . . . . . . . .600603LC/M S Partsand Supplies . . . . . . . . . . . . .483484 Applications . . . . . . . . . . . . . . . . . . . . . . . .604652

    CE and CE/ MS 653668 CE Supplies . . . . . . . . . . . . . . . . . . . . . . . .653654 Capillaries . . . . . . . . . . . . . . . . . . . . . . . . .660666CE Instrument Partsand Supplies . . . . . . . . . . . .655 Solution Kits . . . . . . . . . . . . . . . . . . . . . . .666668CE/M S Instrument Partsand Supplies . . . .656659

    ICP-MS 669690 7500 ICP-MS Supplies . . . . . . . . . . . . . . . .669678 ICP-M S Standards . . . . . . . . . . . . . . . . . . .6896904500 ICP-MS Supplies . . . . . . . . . . . . . . . .679688

    UV-Vis 691699 Cellsand Cell Supplies . . . . . . . . . . . . . . . .691694 Dissolution Testing Supplies . . . . . . . . . . . . . . . .698Tubing and Fittings . . . . . . . . . . . . . . . . . . . . . . .695 Chemical Standardsand AccessoryKits . . . . . . .699Spectrophotometer Supplies . . . . . . . . . . .696697

    Indices 700744 Alphabetical . . . . . . . . . . . . . . . . . . . . . . .701707 Part Number . . . . . . . . . . . . . . . . . . . . . . .720744Compound . . . . . . . . . . . . . . . . . . . . . . . . .708719

    Ordering Information 745752 EasyOrdering Termsand Conditions . . . . . .745746 EasyWaysto Order . . . . . . . . . . . . . . . . . .748749Custom Column Orders . . . . . . . . . . . . . . .746748 Order Forms . . . . . . . . . . . . . . . . . . . . . . .750752

  • 8/14/2019 Agilent GC catalog .pdf

    2/750

    www.agilent.com/ chem2

    Information in thisdocument issubject to change without notice.

    Agilent Technologiesreservesthe right to correct anyprinting or typographical error in thiscatalog.

    Pricesin thiscatalog are for reference onlyand are subject to change without notice.

    Application Information in thiscatalog isfor investigational use onlyand isnot intended tobe a complete laboratorydiagnostic procedure or method. The performance characteristicsof the procedureshave not been fullyestablished. The choice of methodologyand proce-duresremainsthe responsibilityof the user and not of Agilent Technologies.

  • 8/14/2019 Agilent GC catalog .pdf

    3/750

    Technical Support Information

    3www.agilent.com/ chem

    Technical Support at Work for YouYou're in the lab and you're busyand something isn't right. When you have a column or sup-

    pliestechnical question, you want the answer NOW. Our Technical Support Specialistsarereadyto answer your call.

    These chemistsspecialize in working together with you to provide the answersyou need tokeep your laboratoryproductivityhigh. Fast answersto your column or suppliestechnicalquestionsare available from Agilent:

    1. Questionspertaining to suppliesfound in thiscatalog, call 1-800-227-9770 in the U.S. andCanada or call your local Agilent salesoffice. Give a brief overview of your questionsordilemma, and a technical expert for that product or processwill be right with you. Allof our technical support specialistsare chemistswith yearsof laboratoryexperience. Theycan provide you with in-depth knowledge and experience in consumablesand accessoriesproduct use and applications.

    2. Column selection questions, in the U.S. and Canada, call 1-800-227-9770 andselect option 4,

    3. Technical Support on the Internet, (Agilent providesworld classtechnical support onlineat www.agilent.com/ chem voted Best LaboratoryProductsM anufacturer website inan independent surveyconducted at PITTCON.)

    Asthe industryleader, Agilent Technologiesbelievesin sharing itswealth of knowledge andinformation with industryprofessionalsto help you work more effectivelyand efficiently.

    Instrument Repair Parts QuestionsInstrument repair partsare not, for the most part, listed in thiscatalog. Rather, theyareidentified in Agilent user or service manuals. If you have questionsabout instrument repairor require instrument repair information, call 1-800-227-9770, option 3, in the U.S. andCanada. Instrument repair partsare available from the Agilent Support M aterialsOrganization. In the U.S., call 1-877-447-7278 for overnight shipment of repair parts. Forrepair partsoutside the U.S., call your authorized Agilent Technologiesdistributor or contactyour local authorized Agilent service representative.

  • 8/14/2019 Agilent GC catalog .pdf

    4/750

    S al e s ,S e r vi c e a ndS u p p o rt

    www.agilent.com/ chem4

    Training/ Services Information

    Chemical Analysis Training ProgramsAgilent Technologiesprovidescarefullyplanned, effective training coursesin using and

    maintaining Agilent chemical analysishardware and software products.You can obtain information, see course schedulesand register by:

    Logging on to www.agilent.com/ chem and go to the Education link under chemical/biochemical Calling toll-free: 1-800-227-9770 in the U.S. and Canada, or Contacting you Agilent salesrepresentative

    Service Bundles Meet Specific Needsfor Less CostSupport Services for Agilent InstrumentsSpecial service bundlescontain essential servicesto keep your chemical analysisinstrumentsin top condition for dependable operation. These bundlescost lessthan purchasing eachservice individually.

    Petrochemical BundleFor the specific needsof the petroleum, chemical, petrochemical and other industriesnotsubject to pharmaceutical regulatorycompliance, thisservice bundle provides:

    Telephone Support to Isolate and Resolve Hardware ProblemsIncluded Without Charge At-Your-Site Service with Consumablesused during Repair All Off-Site Instrument Repair Services Annual On-Site Preventive M aintenance

    Pharmaceutical BundleFor the pharmaceutical, agricultural and other industriesthat must complywith rigorousqualityand regulatoryrequirements, thisservice bundle provides:

    Telephone Support to Isolate and Resolve Hardware ProblemsIncluded Without Charge At-Your-Site Service with Consumablesused during Repair Annual On-Site Preventive M aintenance Annual Operational Qualification/Performance Verification

  • 8/14/2019 Agilent GC catalog .pdf

    5/750

    Services Information

    5www.agilent.com/ chem

    Agilent Support Service Features Advantages to YouRepair At-Your-Site Instrument Repair Telephone support, with accessto highly Fixed annual cost for parts, allowing

    trained technical support professionals predictable budget management Travel expensesand labor cost for customer Selection of response timesto suit your

    service professional uptime and budget requirements Partsfor on-site repair A choice of response timesOptional Coverage

    Consumablesused during repair

    Off-Site Instrument Repair* Option 1 Lower-cost support than on-site repairReplacement with identical instrument Extensive diagnostic and testing that are notthe fastest wayto resolve a problem feasible with on-site maintenance or repair

    Option 2Return to Agilent for repair

    Maintenance Preventive Maintenance* Expert cleaning, adjusting, lubricating, or M aximized instrument uptimeinspecting Extended instrument life

    Travel and labor costsincluded Confidence in the integrityof your A predefined checklist of preventive main- measurements

    tenance proceduresfor consistent servicefrom laboratoryto laboratory

    MassSpectrometer Ion On-site disassembly Laboratorystaff can devote more time to

    Source Cleaning* Cleaning chemistry, not instrument cleaning Re-assembling Efficient cleaning for minimum downtime Testing

    Qualification Operational Qualification/ Verification and documentation of an The evidence needed to help you satisfyPerformance Verification* instrumentsabilityto meet specified criteria regulatoryagencies

    Proceduresand documentation that fit the No need to write your own standardrequirementsof GLP, ISO 9000, and other operating proceduresto qualifyAgilentregulatoryagencies instrumentsand train your staff

    M easuring equipment traceable to national Consistent and traceable resultsamong alland international standards your laboratoriesand improved method

    Preventive maintenance isrecommended transferbefore Operational Qualification/Performance Confidence in the integrityof yourVerification measurements, with traceable, documented

    chainsfrom sample introduction to reporting

    Software Telephone Support and Telephone assistance from highlytrained Fast problem identification and resolutionUpdatesfor Software technical professionalsto isolate and Fixed annual cost for software updates, for

    resolve software problems predictable budget management All enhancementsto the original chemical Timelyand convenient wayto remain

    analysisapplication software purchase current with the latest features, enhancing Agilent software statusbulletinsthat laboratorycapability

    identifydiscovered defectsand Cost-effective coverage for additional,recommend workarounds identical systemsat a single location

    *For selected Agilent instruments

    Configure Your Own Support PackageSupport Services for Agilent InstrumentsYou can protect your investment byselecting from a menu of Agilent support services. You canpurchase onlywhat you need, for maximum flexibilityin meeting your laboratoryperformanceand budget objectives.

  • 8/14/2019 Agilent GC catalog .pdf

    6/750

  • 8/14/2019 Agilent GC catalog .pdf

    7/750

    Agilent Offices Worldwide

    7www.agilent.com/ chem

    SpainAgilent Technologies Spain, S.L.Grupo de AnlisisQumico

    Ctra. N-VI, Km 18,20028230 LasRozas, M adridPhone: 901 11 68 90Fax: 34 916 376 [email protected]

    SwedenAgilent Technologies Sweden AB,Box 52, 164 94 Kista Phone: 08 506 489 50Fax: 08 506 489 51

    SwitzerlandAgilent Technologies (Schweiz AG) Chemische AnalysentechnikIn den Luberzen 298902 Urdorf Phone: 0848 803 560Fax: 01 735 97 [email protected]

    TaiwanAgilent Technologies Taiwan Ltd 13th Floor, 10 Syh-Wei, 4th RoadKaohsiung 802Phone: 886-7-337-7631Fax: 886-7-536-2595

    Agilent Technologies Taiwan Ltd 8F, No. 2, Sec. 1, Fushing S. RoadTaipei 104TaiwanRepublic of ChinaPhone: 886-2-2734-5686Fax: [email protected]

    ThailandAgilent Technologies (Thailand) Ltd Vibulthani Tower 11, 23-25th Floor3199 Rama IV Road Klong Tan,Klong Toey, Bangkok 10110Phone: 662-661-3900 Ext 3103Fax: 662-661-3941

    Agilent Technologies (Thailand) Ltd 267/42 Sukhumvit Road, TambolM ap Ta Phut, Amphur MuangRayong 21150Phone: 662-38-607708Fax: 662-38-607710

    United KingdomAgilent Technologies UK Limited Lakeside

    Cheadle Royal BusinessParkStockportCheshire SK8 3GRPhone: 0845 712 5292Fax: 0161 492 [email protected]

    United StatesAgilent Technologies, Chemical Analysis Group North American Sales,Customer Contact Center,2850 Centerville RoadWilmington, Delaware 19808Phone: 800-227-9770Fax: [email protected]/chem

    VenezuelaAgilent Technologies de Venezuela C.AAv. Francisco de MirandaTorre HP, Piso 12Caracas, CP 01060Phone: (58212)-209-4613Fax: (58212)[email protected]

    VietnamAgilent Technologies (Vietnam) Ltd Unit 503-504, 5th Floor 30Nguyen Du Hai Ba Trung DistrictPhone: 844-943-0701/4Fax: 844-943-0703

    Note: For a complete listing of authorized distributors, visit our websitewww.agilent.com/ chem or contact your nearest Agilent office.

  • 8/14/2019 Agilent GC catalog .pdf

    8/750

    www.agilent.com/ chem8

    Web InformationHave you been to the Agilent Chemical AnalysisWeb Site lately?Go to www.agilent.com/ chem and find what you need, when you need it:

    Online ordering: instruments, supplies, and software

    Product availability

    Customer-specific product pricing

    Quick Buyfeature makesrepeat purchaseseasyand fast

    Order statusand tracking

    Order history

    Save and retrieve quotes FrequentlyAsked Questions: Answersto the most common technical questionsabout our

    products

    Technical Support Assistant: A logical step-by-step approach to help you solve commonproblems

    Technical Document Library: A searchable collection of service and support documents

    GC, LC, and CE Reference Chromatogram Libraries: A searchable collection of nearlyathousand chemical compounds

    Operating manuals, installation guides

    Illustrated PartsBreakdowns: Instrument diagramsto help you identifya part or find a partnumber

    Software StatusBulletins: Known software defects, work-arounds, and patches

    And it isgrowing everyday!

    Register on our website todayand sign up for our monthlyemail newsletter to keep up withthe new featuresastheyare added to our #1 rated website.

  • 8/14/2019 Agilent GC catalog .pdf

    9/750

    Featured Products

    9www.agilent.com/ chem

    Demonstrating the Value of Deep KnowledgeWere calling them Featured Products, but theyare much more than that. Theyrepresent

    the whole new approach that Agilent istaking to itsbusiness. We realize that you dont justneed the highest qualityinstruments, columns, and supplies; you need a partner who canbring you solutionsbased on long experience and expert insight.

    Thatswhat each of the products in thissection represents. From an item asspecific asapatented new vial for extreme recovery, to the comprehensive information we pack into ourwebsite, each isa wayfor Agilent to share 35 yearsof dailywork byhundredsof technicalexpertsin your application area on the instrumentsyou use. Better still, each product isdesigned to make your job easier and your lab more productive, which iswhat a true partner-ship isall about.

    2002 Featured Products New 96 well platesand cover matsfor well plate autosamplers: Sample Preparation

    Section, page 113 M icro-V economical microsampling vialsfor Agilent autosamplers: General Chromatography,

    pages16, 21, 25 Zorbax Solid Phase Extraction sample preparation products: Sample Preparation,

    page 114 AccuBONDII SPE cartridgesin a wide varietyof phases: Sample Preparation, page 120 Extreme Recovery1.5 mL crimp cap vials: General Chromatography, page 22 Interseal capswith bonded septa for 2 mL screw top vials: General Chromatography,

    page 17 Electronic crimpersand decappersfor 2 mL and 20 mm vials: General Chromatography,

    page 37 Expanded offering of gaspurification devices, including the Big Universal Trap: General

    Chromatography, page 47 Comprehensive line of flowmetersfrom the classic digital bubble metersto combination

    flowmeter/leak detector, the FlowTracker 2000: General Chromatography, page 73 The new consolidated J&W Scientific brand of GC columns: GC and GC/M S Section,

    pages217323 Poroshell particle design HPLC columnsfor high velocityand high resolution of protein

    separations: LC and LC/M S Section, pages535536 Gel filtration chromatographycolumnsfrom Shodex: LC and LC/M S Section, page 586587 Zorbax SB-Aq Rapid Resolution LC columnsfor polar analytes: LC and LC/M S Section,

    page 530531 100 mm LC columns: LC and LC/M S Column Section Agilent M icroBore and CapillaryLC columns: LC and LC/M S Section, pages560561

    Zorbax 300Extend LC columnsfor excellent resolution and long lasting stabilityfrompH 2 to 11.5: LC and LC/M S Section, pages547559

    Agilent Chemical AnalysisWebsite: www.agilent.com/ chem

    Screw caps with Integrated Septa

    Electronic Crimper and Decapper

    GC Capillary Column

    Zorbax SPE Product s

  • 8/14/2019 Agilent GC catalog .pdf

    10/750

    www.agilent.com/ chem10

    General ChromatographyTable of Contents

    G e n e r alCh r o m at o g r a ph y

    General Chromatography Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

    Vials, Caps and Septa . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12Septum Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13Vial Identification Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14Screw Top Vials, Caps, Septa and Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1519Crimp Top Vials, Capsand Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2023Snap Top Vials, Capsand Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2427Wide Opening Inserts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27288-425 Screw Top Vials, Caps, Septa and Inserts . . . . . . . . . . . . . . . . . . . . . . . . . .29314 mL Vials, Capsand Septa . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32Headspace Crimp Top Vials, Caps, Septa and Kits . . . . . . . . . . . . . . . . . . . . . . . . .3335General Purpose Sample and Storage Vials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3536Crimping and Decapping Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3738Vial Racks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38

    Syringes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39Autosampler Syringes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4042M anual Syringes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4346

    Gas Management Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47GasPurifier Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4849GasPurifier CapacityChart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50M oisture Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5155Oxygen Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5657Hydrocarbon Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5759Combination Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6062GasPurification Systems, Accessoriesand Kits . . . . . . . . . . . . . . . . . . . . . . . . . . .6370GC Installation Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7172Flowmeter Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73Flowmeter Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74Flowmeters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7579Leak Detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80Regulatorsand Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8182

    Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8391

    Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92GPC/GFC Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92CE and UV-VisStandards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9394HPLC, LC/M S and RI Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9495GC Column Test Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9697

    GC and GC/M S Instrument Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .98101

    Integrators, Integrator Supplies and Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .102106

    Books, Learning Software and CDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .107109

  • 8/14/2019 Agilent GC catalog .pdf

    11/750

    General ChromatographyGeneral Supplies

    11www.agilent.com/ chem

    Making Your Chromatography Lab MoreProductiveLabsrun smoothlywhen everydetail isright. With Agilent suppliesand accessories, you canbe confident that theyare. All of our productshave been designed or selected byour instru-ment design teams, manufactured to our demanding specifications, and tested in a varietyof conditionsto ensure a PerfectFit with Agilent instruments. That painstaking care registeredto ISO 9001 ensuresthat Agilent instrumentswill perform at optimum levelswhen you useAgilent products.

    In the following pages, you'll find what you need to make your lab more productive dayafter day. You'll find the staples, from capsand vialsto manual and autosampler syringes.You'll find gasmanagement supplies, such aspurifiers, regulators, flowmeters, and leakdetectors. Hardware. Standards. Plusproductsthat directlyshare our product and applicationknowledge with you the latest in technical publications, learning software, and CDs togive you a competitive edge.

  • 8/14/2019 Agilent GC catalog .pdf

    12/750

    www.agilent.com/ chem12

    VialsVials, Caps and Septa

    G e n e r alCh r o m at o g r a ph y

    Vials, Caps and Septa All Agilent Vials use USP Type 1 Borosilicate GlassAgilent Technologiesvialsare made onlyfrom Type 1 Borosilicate glassand are tightlycon-trolled for dimensional accuracyusing the Optoelectronic system. The vialscome in crimp top,screw top or snap top closure and are also available in deactivated or non-deactivated versions.

    Before doing an injection, you should think about:

    Type of closure: Crimp top vials, screw top vialsor snap top vials While crimp topsare the least expensive, theyneed a crimping tool and the capsare not

    reusable. Screw top vialsare the perfect medium for reusabilityand low evaporation.

    Type of glass or polypropylene: Clear or amber glass, polypropylene vials

    If your sample islight sensitive, you maychoose amber glass. For most applications, standard clear glassissufficient. For samplesthat maystick to glassor chemically react with glass, use polypropylene.

    Deactivated/ non-deactivated: For samplesthat interact with the highlypolar silanol groupson the glasssurface, a

    deactivation procedure isperformed on the vials.

    Need for inserts: Flat or conical with polyspring If you onlyhave a small amount of sample, you maychoose to place a limited volume insert

    inside the vial or choose micro sampling vialslike M icro-V or High Recovery. Polyspring at the bottom of the conical insert keepsit aligned for proper injection.

    Type of septa: Dependson the propertiesof your sample, use the septum selection guide on the

    following page.

    40 % LARGER OPENING THAN THE STANDARD MOUTH VIALTIGHTLY CONTROLLED DIMENSIONS

    OPTIONAL WRITE-ON PATCH WITH GRADUATIONS

    FLAT BOTTOM FOR INSERT STABILITY

    32 mm

    12 mm

    1.5 mL

    Wide Opening 2 mL Vial

  • 8/14/2019 Agilent GC catalog .pdf

    13/750

    VialsGeneral Information/Vials, Caps and Septa

    13www.agilent.com/ chem

    Caps and Septa

    Vial cap septa are a critical link to optimal analysis. Each septum isspecified to complementthe overall system and enhance chemical performance. Aswith all Agilent components,rigoroustesting and product specificationsare done before offering the product.

    Agilent vial cap septa are speciallyformulated and constructed to provide optimum systemperformance with minimal coring and superior chemical inertness. The softnessor hardness(durometer) ismatched to the instrument and designed to work well with syringesand samples.

    The size of the septum iscritical to proper sealing. All Agilent septa are specificallysized forproper sealing. Our thinnest septa have a special detail built into the cap to minimize septacoring and eliminate the need to replace capswith extended usage.

    Autosampler Compatibil ity Chart: Agilent wide opening vialsare compatible withAgilent aswell asnon-Agilent autosamplers.

    Autosampler ModelAgilent Technologies All Models Except CE, that cannot be pressurizedBeckman 501, 507

    Dynatech 42 Vial Tray, LC 2000

    Finnigan A200S

    Fisons AS 800

    Gilson 231-401, 232-402, 201/202, 221/222, Aspec

    Hewlett-Packard All M odelsExcept CE

    Hitachi AS-2000, AS-4000

    L.E.A.P. A200S

    LDC M arathon, PromisPerkin-Elmer 4900, Integral 4000, Autosystem GC, ISS

    100/ISS 200, LC 600 42-Tray

    Spark M arathon/Promis, SPH 125

    Spectra-Physics SpectraSystem, 8875/8880

    Varian 8100/8200, 8035/9095, 8000, M arathon, Vista

    Waters 2690, Alliance Systems

    Septum Select ion Guide SeptumMaterial Compatible with Incompatible with Resealability Max. Temperature

    Rubber (Natural/Butyl) ACN, acetone, DM F, alcohols, Chlorinated solvents, aromatics, Excellent < 100 Cdiethylamine, DM SO, phenols hydrocarbons, carbon disulfide

    PTFE/Natural or Butyl Rubber PTFE resistance until punctured, then septa Good < 100 Cor liner will have compatibilityof rubber

    Silicone/Silicone Rubber Alcohol, acetone, ether, DMF, DMSO ACN, THF, benzene chloroform, Excellent < 200 Cpyridine, toluene, hexane, heptane

    PTFE/Silicone, PTFE/Silicone/PTFE PTFE resistance until punctured, then Average < 200 Csepta will have compatibilityof silicone

    VITON Chlorinated solvents, benzene, DM F, DM SO, ACN, THF, pyridine, Good < 260 Ctoluene, alcohols, hexane, heptane dioxane, methanol, acetone

  • 8/14/2019 Agilent GC catalog .pdf

    14/750

    Wide Opening Screw TopVials: Septum Diameter 9 mm Wide Opening Crimp Top Vials: Septum Diameter 11 mm

    Wide Opening Snap Top Vials

    9301-0977

    Insertsfor 2 mL,12x32 mmWide Opening Vials

    5181-3375

    5182-3454

    5182-0567

    5182-0544

    5183-4510

    5182-0567

    9301-0978

    5181-1270

    5183-2085

    5181-3377

    9301-0978

    5183-4731

    5183-4731

    9301-0977

    1.5 mL 1.5 mL 1.0 mL

    100 L 300 L 100 L

    5183-2030

    1.5 mL

    5183-4428

    Narrow Opening ScrewTop Vials

    1.5 mL

    100 L100 L300 L

    1.0 mL1.5 mL1.5 mL

    250 L100 L100 L

    5183-2088

    5183-2089

    Insertsfor 2 mL, 12x32 mmNarrow Opening Screw Top Vials

    5183-2090

    250 L 100 L100 L

    Headspace Crimp Top Vials Flat and Rounded Bottom

    5180-0806

    5180-0805

    Vialsfor Agilent LC Instruments

    9301-1377

    500 l 700 L 6 mL

    5182-0837

    20 mL

    T r u e s c a l e :

    7 5 m m x

    2 2 m m

    5183-4474

    20 mL

    5182-0838

    10 mL

    T r u e s c a l e :

    4 5 m m x 2

    2 m m

    5183-4475

    10 mL

    5182-0714

    1.5 mL

    3 2 m m x

    1 2 m m

    3 1 m m

    G e n e r alCh r o m at o g r a ph y

    VialsIdentification Chart

    www.agilent.com/ chem14

    Agilent Vial Identification Chart and Actual Fill Volumes

    5184-3551

    5185-5821

  • 8/14/2019 Agilent GC catalog .pdf

    15/750

    VialsScrew Top Vials

    15www.agilent.com/ chem

    Agilent Screw Top Vials, Caps, Septa and KitsCombine the excellent autosampler handling of a crimp cap profile with the ease of a screw

    cap. The screw capsand precision fit septa give a secure seal with the microvolume inserts.

    Highlights 2 mL, 12 x 32 mm 40% larger opening than standard narrow

    opening vials Unique thread design for consistently

    secure seal (9 x 425) Precision-formed neck for optimal robotic

    arm handling

    Rigorousqualityassurance for dimensionalconsistencyfrom lot to lot

    Uniformlyflat bottom ensurescompatibilitywith inserts

    Optional ceramic write-on spot with fillmarks

    Select from several compatible micro-volume inserts

    Screw Top VialsWide Opening Screw Top Glass VialsVersatile 2 mL, 12 x 32 mm wide opening vialsdesigned for autosamplerswith rotating orrobotic arm trays.

    Deactivated Wide Opening Screw Top Glass VialsThese wide opening 2 mL, 12 x 32 mm vialsare created using a deactivation processtoeliminate sample interactions. Ready-to-use for the analysisof polar compoundssuch asphenols, proteins, antibodies, amines, metabolites, herbicidesand pesticides.

    Deactivated Screw Top, 2 mL Vials Unit Part No.Clear deactivated wide opening screw top 100/pk 5183-2070

    Clear deactivated wide opening screw top, write-on spot 100/pk 5183-2071

    Amber deactivated wide opening screw top, write-on spot 100/pk 5183-2072

    Helpful Hint: M icrovolume insertsare shown on pages27 28.

    Screw Top, 2 mL Vials Unit Part No.Clear wide opening screw top 100/pk 5182-0714

    Clear wide opening screw top, write-on spot 100/pk 5182-0715

    Amber wide opening screw top, write-on spot 100/pk 5182-0716

    Clear wide opening screw top 1000/cs* 5183-2067

    Clear wide opening screw top, write-on spot 1000/cs* 5183-2068

    Amber wide opening screw top, write-on spot 1000/cs* 5183-2069

    *Case includes 10 packs of 100 vials

    P/N 5182-0714, 5182-0715, 5182-0716

    P/N 5183-2070, 5183-2071, 5183-2072

    http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2070http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2071http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2072http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0714http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0715http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0716http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2067http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2068http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2069http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2072http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2071http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2070http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2069http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2068http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2067http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0716http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0715http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0714
  • 8/14/2019 Agilent GC catalog .pdf

    16/750

    Screw Top Micro-V Vials Unit Part No.M icro-V vial, clear, screw top 100/pk 5184-3550

    M icro-V vial, amber, screw top 100/pk 5184-3554

    www.agilent.com/ chem16

    VialsScrew Top Vials and Caps

    G e n e r alCh r o m at o g r a ph y

    Screw Top Micro-V Vial 12 x 32 mm, Type 1 Borosilicate glass Compatible with standard screw closures 1.5 mL total volume Lessthan 5 L dead volume Designed for center needle position during sample injection

    (not recommended for Vortex)

    1.5 mL Wide Opening Screw Top High Recovery Glass VialsWide opening, 1.5 mL vialswith 30 L reservoir. For sample concentration and injection with-out transferring to microvolume inserts.

    Screw Top High Recovery Vials Unit Part No.Clear high recoveryscrew top 100/pk 5183-2030

    Amber high recoveryscrew top, write-on spot 100/pk 5183-2073

    P/ N 5183-2030, 5183-2073

    Screw CapsPolypropylene Screw Caps with Septa for

    Wide Opening Screw Top VialsThese precision-fit septa provide an evaporation proof seal. (See the Septum Selection Guideto choose the septum best suited for your application.)

    Screw Caps Unit Part No.Blue, PTFE/red silicone rubber septa* 100/pk 5182-0717

    Green, PTFE/red silicone rubber septa* 100/pk 5182-0718

    Red, PTFE/red silicone rubber septa* 100/pk 5182-0719

    Black, PTFE/red silicone rubber septa* 100/pk 5185-5838

    Blue, PTFE/silicone septa 100/pk 5182-0720

    Green, PTFE/silicone septa 100/pk 5182-0721

    Red, PTFE/silicone septa 100/pk 5182-0722

    Blue, PTFE/silicone/PTFE septa 100/pk 5182-0723

    Green, PTFE/silicone/PTFE septa 100/pk 5182-0724

    Red, PTFE/silicone/PTFE septa 100/pk 5182-0725

    Blue, pre-slit PTFE/silicone septa 100/pk 5183-2076

    Green, pre-slit PTFE/silicone septa 100/pk 5183-2077

    Red, pre-slit PTFE/silicone septa 100/pk 5183-2078

    *Commonly referred to as red rubber

    P/ N 5182-0717, 5182-0718, 5182-0719

    P/ N 5184-3550

    http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5184-3550http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5184-3554http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2030http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2073http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0717http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0718http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0719http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5185-5838http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0720http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0721http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0722http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0723http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0724http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0725http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2076http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2077http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2078http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2078http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2077http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2076http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0725http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0724http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0723http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0722http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0721http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0720http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5185-5838http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0719http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0718http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0717http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5184-3554http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5184-3550http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2073http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2030
  • 8/14/2019 Agilent GC catalog .pdf

    17/750

    VialsScrew Caps and Septa

    17www.agilent.com/ chem

    P/N 5185-5823

    P/N 5182-0728, 5182-0727, 5182-0726

    New Screw Caps with Integrated SeptaBonded capscombine innovation with time saving convenience. Thischemically inert patent-ed processproducesa true bond at the molecular level of the septa and plastic cap, eliminat-ing excessevaporation and providing proper seal with the vial. Septa are completelysecureand will not fall into the vial during injection. These capsare made with PTFE/Silicone septafor excellent chemical resistance and multiple injections.

    Screw Caps with Integrated Septa Unit Part No.Blue polypropylene cap, bonded PTFE/silicone septa 100/pk 5185-5823

    Blue polypropylene cap, bonded pre-slit PTFE/silicone septa 100/pk 5185-5824

    Polypropylene Screw Caps (no septa)An economical choice. Use capsand replace septa when needed. Choose from three capcolorsfor separating assays, lots, standards, etc.

    Screw Caps without Septa Unit Part No.Blue open top screw caps 100/pk 5182-0728

    Green open top screw caps 100/pk 5182-0727

    Red open top screw caps 100/pk 5182-0726

    Blue PTFE-lined solid top screw caps(for storage) 100/pk 5183-2075

    SeptaSepta for Wide Opening Screw CapsSepta for Screw Caps Unit Part No.IvoryPTFE/red silicone rubber septa* 100/pk 5182-0731

    Red PTFE/white silicone/red PTFE septa 100/pk 5182-0729

    Blue pre-slit PTFE/white silicone septa 100/pk 5183-2074

    Red PTFE/white silicone septa 100/pk 5182-0730

    *Commonly referred to as red rubber Assortment of Septa for Wide Opening Screw Caps

    http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5185-5823http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5185-5824http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0728http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0727http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0726http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2075http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0731http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0729http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2074http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0730http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0730http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2074http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0729http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0731http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2075http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0726http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0727http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0728http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5185-5824http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5185-5823
  • 8/14/2019 Agilent GC catalog .pdf

    18/750

    www.agilent.com/ chem18

    VialsScrew Top Vial Kits

    G e n e r alCh r o m at o g r a ph y

    Vial KitsNon-Assembled, 2 mL Wide Opening Screw Top

    Glass Vial Convenience PacksScrew Top Convenience Packsare an easywayto get 500 of each component using onecatalog number. Packed in our six drawer reusable blue plastic cabinet, 500 screw top vialsand screw capswith septa installed are kept handyand dust-free.

    Note: Review the Septum Selection Guide to choose the septum best suited for your application.

    Screw Top Vials and Caps Kits Unit Part No.Clear vials, blue screw caps, PTFE/red silicone rubber septa* 500/pk 5182-0732

    Clear vialswith write-on spot, blue screw caps, 500/pk 5182-0867PTFE/red silicone rubber septa*

    Amber vialswith write-on spot, green screw caps, 500/pk 5182-0733PTFE/red silicone rubber septa*

    Clear vials, blue screw caps, PTFE/silicone/PTFE septa 500/pk 5182-0736

    Clear vialswith write-on spot, blue screw caps, 500/pk 5182-0869PTFE/silicone/PTFE septa

    Amber vialswith write-on spot, green screw caps, 500/pk 5182-0737PTFE/silicone/PTFE septa

    Clear vials, blue screw caps, PTFE/silicone septa 500/pk 5182-0734

    Clear vialswith write-on spot, blue screw caps, 500/pk 5182-0868PTFE/silicone septa

    Amber vialswith write-on spot, green screw caps, 500/pk 5182-0735

    PTFE/silicone septaClear vials, blue screw caps, pre-slit blue 500/pk 5183-2079PTFE silicone septa

    Clear vialswith write-on spot, blue screw caps, pre-slit 500/pk 5183-2080blue PTFE silicone septa

    Amber vialswith write-on spot, green screw caps, pre-slit 500/pk 5183-2081blue PTFE silicone septa

    *Commonly referred to as red rubber

    Helpful Hint: For LC specific vialsplease refer to the LC suppliessection.

    Screw Top Vial Kit

    http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0732http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0867http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0867http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0733http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0733http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0736http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0869http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0869http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0737http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0737http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0734http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0868http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0868http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0735http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0735http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2079http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2079http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2080http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2080http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2081http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2081http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2081http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2080http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2079http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0735http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0868http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0734http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0737http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0869http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0736http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0733http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0867http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0732
  • 8/14/2019 Agilent GC catalog .pdf

    19/750

    VialsScrew Top Vial Kits

    19www.agilent.com/ chem

    Pre-Assembled, 2 mL Wide Opening Screw Top Glass VialPacks

    Screw Top Vial Pre-assembled Packscome readyto use with cap and septum of your choiceattached to the vial. A time/labor-saving product for use on your Agilent Autosampler or anyrotating trayautomatic sampler.

    Note: Review the Septum Selection Guide to choose the septum best suited for your application.

    Pre-Assembled Screw Top Kits Unit Part No.Clear vials, blue screw caps, PTFE/red silicone rubber septa* 100/pk 5182-0553

    Clear vialswith write-on spot, blue screw caps, 100/pk 5182-0864PTFE/red silicone rubber septa*

    Amber vialswith write-on spot, green screw caps, 100/pk 5182-0554PTFE/red silicone rubber septa*

    Clear vials, blue screw caps, PTFE/silicone/PTFE septa 100/pk 5182-0555Clear vialswith write-on spot, blue screw caps, 100/pk 5182-0866PTFE/silicone/PTFE septa

    Amber vialswith write-on spot, green screw caps, 100/pk 5182-0556PTFE/silicone/PTFE septa

    Clear vials, blue screw caps, PTFE/silicone septa 100/pk 5182-0557

    Clear vialswith write-on spot, blue screw caps, 100/pk 5182-0865PTFE/silicone septa

    Amber vialswith write-on spot, green screw caps, 100/pk 5182-0558PTFE/silicone septa

    Clear vials, blue screw caps, pre-slit blue 100/pk 5183-2082

    PTFE silicone septaClear vialswith write-on spot, blue screw caps, 100/pk 5183-2083pre-slit blue PTFE silicone septa

    *Commonly referred to as red rubber

    Preassembled Vial Pack

    http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0553http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0864http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0864http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0554http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0554http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0555http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0866http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0866http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0556http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0556http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0557http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0865http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0865http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0558http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0558http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2082http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2082http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2083http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2083http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2083http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2082http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0558http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0865http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0557http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0556http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0866http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0555http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0554http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0864http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0553
  • 8/14/2019 Agilent GC catalog .pdf

    20/750

    P/ N 5181-3375, 5182-0543, 5181-3376

    www.agilent.com/ chem20

    VialsCrimp Top Vials

    G e n e r alCh r o m at o g r a ph y

    Agilent Crimp Top Vials, Caps and KitsThe wide opening crimp cap providesa larger target area for improved auto-sampler needle

    accuracy. Select from four cap colorsand a varietyof septa. Whatever your crimp top vialneeds, Agilent haswhat you are looking for.

    Highlights 2 mL, 12 x 32 mm Tightlycontrolled crown for improved crimping Precision-formed neck for improved autosampler handling 40% larger opening than standard narrow opening vials Rigorousqualityassurance providesdimensional consistencyfrom lot to lot Uniformlyflat bottom ensurescompatibilitywith inserts Optional ceramic write-on spot with fill marks

    Crimp Top, 2 mL Vials Unit Part No.Clear wide opening crimp top 100/pk 5181-3375

    Clear wide opening crimp top, write-on spot 100/pk 5182-0543

    Amber wide opening crimp top, write-on spot 100/pk 5181-3376

    Clear wide opening crimp top 1000/cs* 5183-4491

    Clear wide opening crimp top, write-on spot 1000/cs* 5183-4492

    Amber wide opening crimp top, write-on spot 1000/cs* 5183-4493

    *Case includes 10 packs of 100 vials

    VialsWide Opening Crimp Top Glass VialsWide opening 2 mL, 12 x 32 mm vials. The outer diameter of the crimp head is11 mm.M icrovolume insertsfor microsampling are shown on pages27 28.

    http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5181-3375http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0543http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5181-3376http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4491http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4492http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4493http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4493http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4492http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4491http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5181-3376http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0543http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5181-3375
  • 8/14/2019 Agilent GC catalog .pdf

    21/750

  • 8/14/2019 Agilent GC catalog .pdf

    22/750

    www.agilent.com/ chem22

    VialsCrimp Top Vials

    G e n e r alCh r o m at o g r a ph y

    New Extreme Recovery Vial Patented design with stable base for GC autosamplers Uniform internal surface without anyridgesto hold back sample It haswider neck opening for easypipetting Increased sample volume capacityversusstandard inserts Low residual volume for smaller volume injectionswithout using the inserts Safe to use with Vortex for sample concentration

    Wide Opening Crimp Top Polypropylene VialsWide opening 12 x 32 mm vialsmanufactured from virgin polypropylene, meeting the

    requirementsof 21 CFR 177.1520. Polypropylene ischemicallyresistant and the material of choice for pH sensitive samples, sodium or heavymetalsanalysis. Polypropylene is translu-cent and able to withstand temperaturesto 135 C. Use with crimp or snap caps.

    Extreme Recovery Crimp Top Vials Unit Part No.1.5 mL Extreme Recoveryclear crimp top vial 100/pk 5185-5821

    Polypropylene Crimp Top Vials Unit Part No.Polypropylene wide opening crimp top, 1 mL 100/pk 5182-0567

    Polypropylene wide opening crimp top, 300 L 1000/pk 9301-0978

    P/ N 5185-5821

    P/ N 5182-0567, 9301-0978

    Wide Opening Crimp Top Glass/Plastic VialsM ost popular 12 x 32 mm wide opening vialsfor economical and effective microsampling.

    Polypropylene bodywith a glassflanged insert molded to the inside. Sample comesin contactonlywith the 100 L high qualityglassinsert and the septum. Use with crimp or snap caps.

    Note: M icrovolume insertsare shown on pages27 28.

    Glass/ Plastic Crimp Top Vials Unit Part No.Glasslined polypropylene wide opening crimp top, 100 L 100/pk 9301-0977P/ N 9301-0977

    http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5185-5821http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0567http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=9301-0978http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=9301-0977http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=9301-0977http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=9301-0978http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0567http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5185-5821
  • 8/14/2019 Agilent GC catalog .pdf

    23/750

    VialsCrimp Caps/ Vial Kits

    23www.agilent.com/ chem

    Vial KitsNon-Assembled, 2 mL Wide Opening Crimp Top Glass

    Vial Convenience PacksCrimp Top Vial Convenience Packsare an easywayto get 500 of each vial component using

    one catalog number. Packed in our six drawer reusable blue plastic cabinet, all itemsare kepthandyand dust-free.

    CapsCrimp Caps with SeptaNote: Review the Septum Selection Guide to choose the septum best suited for your application.

    11 mmCrimp Caps with Septa Unit Part No.Silver aluminum, clear PTFE/red natural rubber septa 100/pk 5181-1210

    Blue aluminum, clear PTFE/red natural rubber septa 100/pk 5181-1215

    Green aluminum, clear PTFE/red natural rubber septa 100/pk 5181-1216

    Red aluminum, clear PTFE/red natural rubber septa 100/pk 5181-1217

    Silver aluminum, PTFE/silicone/PTFE septa 100/pk 5181-1211

    Silver aluminum, PTFE/silicone septa 100/pk 5182-0552

    Silver aluminum, black Viton septa 100/pk 5181-1212

    Silver aluminum, clear PTFE/red natural rubber septa 1000/pk 5183-4498Silver aluminum, PTFE/silicone/PTFE septa 1000/pk 5183-4499

    Silver aluminum, PTFE/silicone septa 1000/pk 5183-4500

    Silver aluminum, PTFE septa 1000/pk 5182-0871

    Crimp Top Vials and Cap Kits Unit Part No.Clear crimp top vials, silver aluminum crimp caps, PTFE/ 500/pk 5181-3400red rubber septa

    Amber crimp top vialswith write-on spot, silver aluminum 500/pk 5181-8801crimp caps, PTFE/red rubber septa

    P/N 5181-1210, 5181-1215, 5181-1216, 5181-1217

    Crimp Vial Kit

    http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5181-1210http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5181-1215http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5181-1216http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5181-1217http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5181-1211http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0522http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5181-1212http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4498http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4499http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4500http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0871http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5181-3400http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5181-3400http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5181-8801http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5181-8801http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5181-8801http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5181-3400http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0871http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4500http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4499http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4498http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5181-1212http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0522http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5181-1211http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5181-1217http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5181-1216http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5181-1215http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5181-1210
  • 8/14/2019 Agilent GC catalog .pdf

    24/750

    www.agilent.com/ chem24

    VialsSnap Top Vials

    G e n e r alCh r o m at o g r a ph y

    Agilent Snap Top Vials, Caps and KitsThe simple, efficient wayto a secure seal without crimping. It'saseasyaspush-on, pull-off. A

    consistentlysecure seal outperformsthe loose fit of other snap caps. A varietyof snap capswith septa are available on page 26. Crimp capscan also be used with wide opening snaptop vials. Snap cap vialscannot be pressurized. For microsampling, see microvolume insertsfor wide opening vials.

    Highlights 2 mL, 12 x 32 mm Use with any11 mm snap or crimp cap Providesa total seal around the entire circumference of the vial crown 40% larger opening than standard narrow opening vials Precision-formed neck improvesautosampler handling Optional ceramic write-on spot

    Uniformlyflat bottom ensurescompatibilitywith inserts

    VialsWide Opening Snap Top Glass VialsWide opening 2 mL, 12 x 32 mm vials. M icrovolume insertsfor microsampling are shown onpages27 28. Use with snap or crimp caps.

    Snap Top Vials Unit Part No.Clear wide opening snap top, 2 mL 100/pk 5182-0544

    Clear wide opening snap top, 100/pk 5182-0546write-on spot, 2 mL

    Amber wide opening snap top, 100/pk 5182-0545write-on spot, 2 mL

    Clear wide opening snap top, 2 mL 1000/cs* 5183-4504

    Clear wide opening snap top, 1000/cs* 5183-4505write-on spot, 2 mL

    Amber wide opening snap top, 1000/cs* 5183-4506write-on spot, 2 mL

    *Case includes 10 packs of 100 vials

    P/ N 5182-0544, 5182-0546, 5182-0545

    http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0544http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0546http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0546http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0545http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0545http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4504http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4505http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4505http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4506http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4506http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4506http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4505http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4504http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0545http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0546http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0544
  • 8/14/2019 Agilent GC catalog .pdf

    25/750

    VialsSnap Top Vials

    25www.agilent.com/ chem

    Deactivated Wide Opening Snap Top Glass VialsThe 2 mL vialsundergo a deactivation processto eliminate sample interactions. Ready-to-usefor the analysisof polar compoundssuch asphenols, proteins, antibodies, amines, metabo-lites, herbicidesand pesticides.

    Deactivated Snap Top Vials (100/ Pk) Part No.Clear deactivated wide opening snap top, 2 mL 5183-4507

    Clear deactivated wide opening snap top, write-on spot, 2 mL 5183-4508

    Amber deactivated wide opening snap top, write-on spot, 2 mL 5183-4509

    P/N 5183-4507, 5183-4508, 5183-4509

    Wide Opening Snap Top High Recovery Glass VialsWide opening, 1.5 mL vialswith 30 L reservoir. For sample concentration and injectionwithout transferring to microvolume inserts. Use with snap or crimp caps.

    Snap Top High Recovery Glass Vial (100/ Pk) Part No.Clear high recoverysnap top, 1.5 mL with 30 L reservoir 5183-4510

    Snap Top Micro-V Vial 12 x 32 mm, Type 1 Borosilicate glass Compatible with standard snap or crimp closures 1.5 mL total volume

    Lessthan 5 L dead volume Designed for center needle position during sample injection Not recommended for Vortex or in-vial sample concentration

    Snap Top Micro-V Vials Unit Part No.M icro-V vial, clear, snap top 100/pk 5184-3552

    M icro-V vial, amber, snap top 100/pk 5184-3556

    P/N 5183-4510

    P/N 5184-3550, 5184-3551

    Wide Opening Snap Top Polypropylene VialsWide opening 12 x 32 mm vialsmanufactured from virgin polypropylene, meeting the

    requirementsof 21 CFR 177.1520. Polypropylene ischemicallyresistant and the material of choice for pH sensitive samples, sodium or heavymetalsanalysis. Polypropylene istranslucent and able to withstand temperaturesto 135 C. Use with snap or crimp caps.Snap Top Polypropylene Vials Unit Part No.Polypropylene wide opening snap top, 1 mL 100/pk 5182-0567

    Polypropylene wide opening snap top, 300 L 1000/pk 9301-0978

    Polypropylene wide opening snap top, 300 L 1000/pk 5183-4731 P/N 5182-0567, 9301-0978

    http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4507http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4508http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4509http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4510http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5184-3552http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5184-3556http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0567http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=9301-0978http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4731http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4731http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=9301-0978http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0567http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5184-3556http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5184-3552http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4510http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4509http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4508http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4507
  • 8/14/2019 Agilent GC catalog .pdf

    26/750

    Wide Opening Snap Top Glass/Plastic VialsThe most popular 2 mL, 12 x 32 mm wide opening vialsfor economical and effectivemicrosampling. Polypropylene bodywith a glassflanged insert molded to the inside. Samplecomesin contact onlywith the 100 L high qualityglassinsert and the septum. Use withsnap or crimp caps.

    Snap Top Glass/ Plastic Vials (100/ Pk) Part No.Glasslined polypropylene wide opening snap top, 100 L 9301-0977

    Helpful Hint: For a low cost alternative, use microvolume insertsshown on page 28.

    CapsSnap Caps with 11 mm SeptaReview the Septum Selection Guide to choose the septum best suited for your application.

    Snap Caps, 11 mm(100/ Pk) Part No.Clear polyethylene cap, solid polyethylene membrane septa 5182-0542

    Clear polyethylene cap, clear PTFE/red silicone rubber septa* 5182-0550

    Blue polyethylene cap, clear PTFE/red silicone rubber septa* 5182-3458

    Green polyethylene cap, clear PTFE/red silicone rubber septa* 5182-3457

    Red polyethylene cap, clear PTFE/red silicone rubber septa* 5182-3459

    Clear polyethylene cap, PTFE septa 5182-0540

    Clear polyethylene cap, PTFE/silicone/PTFE septa 5182-0566

    Blue polyethylene cap, PTFE/silicone septa 5182-0541

    Clear polyethylene cap, pre-slit PTFE/silicone septa 5183-4511

    Clear polyethylene cap, Viton septa 5182-0870

    *Commonly referred to as red rubber

    www.agilent.com/ chem26

    VialsSnap Top Vials and Caps

    G e n e r alCh r o m at o g r a ph y

    P/ N 9301-0977

    P/ N 5182-0542, 5182-0550, 5182-3458,5182-3457, 5182-3459

    http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=9301-0977http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0542http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0550http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-3458http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-3457http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-3459http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0540http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0566http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0541http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4511http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0870http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0870http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4511http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0541http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0566http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0540http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-3459http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-3457http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-3458http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0550http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0542http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=9301-0977
  • 8/14/2019 Agilent GC catalog .pdf

    27/750

    VialsSnap Top Vials and Caps/ Wide Opening Inserts

    27www.agilent.com/ chem

    Agilent Microvolume Inserts for WideOpening VialsTo meet your microsampling needs, Agilent hasa varietyof microvolume insertswith capaci-tiesand designsthat can transform our vialsfrom full-capacityto limited volume with onesimple step.

    These insertsare compatible with our wide opening screw top, crimp top, and snap top vials.

    Insert Highlights Conical Insertswith Polymer Feet

    Feet act asshock absorber for needle Dead-volume isvirtuallyeliminated Insertsare self-aligning and stand straight

    Flat Bottom Inserts Custom-fit to vial Extremelyflat bottom no push-up

    Conical GlassInserts Pulled-point interior Economical alternative

    Vial KitsNon-Assembled, 2 mL Wide Opening Snap Top Glass VialConvenience PacksSnap top convenience packsare an easywayto get 500 of each vial component using onecatalog number. Packed in our six drawer reusable blue plastic cabinet, snap top vialsandsnap capswith septa are kept handyand dust-free.

    Snap Top Vials and Caps Kits Part No.Clear snap top vials, clear polypropylene snap caps, 5182-0547PTFE/red rubber septa

    Amber snap top vialswith write-on spot, clear polypropylene 5182-0548snap caps, PTFE/red rubber septa

    Snap Top Vial Kit

    http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0547http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0547http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0548http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0548http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0548http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0547
  • 8/14/2019 Agilent GC catalog .pdf

    28/750

    www.agilent.com/ chem28

    VialsWide Opening Inserts

    G e n e r alCh r o m at o g r a ph y

    Conical Inserts with Polymer Feet With the correct default setting on an autosampler, these insertshave practicallyno deadvolume. The syringe needle can strike the bottom of the insert without being damaged. Thepolymer feet act asa shock absorber. Thisallowsall of the sample to be withdrawn. Theseinsertsare self-aligning and stand straight.

    Conical Inserts with Polymer Feet (100/ Pk)* Part No.100 L glassinsertswith polymer feet and mandrel interior 5181-1270

    100 L deactivated glassinsertswith polymer feet and 5181-8872mandrel interior

    100 L polypropylene insertswith polymer feet 5182-0549

    *For use with Agilent Wide Opening Vials

    Conical Glass InsertsConical insertsrequire no springsand are readyto drop into the vial for injections. The mosteconomical choice for microvolume sampling.

    Conical Glass Inserts (100/ Pk)* Part No.100 L pulled-point glassinserts 5183-2085

    *For use with Agilent Wide Opening Vials

    Flat Bottom InsertsAn economical limited-volume alternative. M anufactured with tight tolerancesfor a customfit. The extremelyflat bottom without anypush-up protectssyringe needles.

    Flat BottomInserts (500/ Pk)* Part No.250 L glassflat bottom inserts 5181-3377

    250 L deactivated glassflat bottom inserts 5183-2086

    250 L polypropylene flat bottom inserts 5183-2087

    *For use with Agilent Wide Opening Vials

    P/ N 5181-1270

    P/ N 5183-2085

    P/ N 5181-3377

    http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5181-1270http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5181-8872http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5181-8872http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0549http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2085http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5181-3377http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2086http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2087http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2087http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2086http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5181-3377http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2085http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0549http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5181-8872http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5181-1270
  • 8/14/2019 Agilent GC catalog .pdf

    29/750

    Vials8-425 Screw Top Vials

    29www.agilent.com/ chem

    Vials8-425 Screw Top Glass VialsThese 2 mL, 12 x 32 mm 8-425 vialsaccommodate a varietyof autosamplersoriginallydesigned for narrow neck vials. Use with 8-425 screw caps.

    8-425 Screw Top Glass Vials (100/Pk) Part No.Clear 8-425 screw top, 2 mL 5183-4428

    Amber 8-425 screw top, 2 mL 5183-4429 P/N 5183-4428, 5183-4429

    Agilent Standard Opening Screw Top VialsThe original, smaller opening vial with an 8-425 thread size screw cap. Available with black

    capsand a varietyof septa to meet the needsof your application.

    Note: For microvolume sampling, see our M icrovolume Insertssection.

    Vial Highlights 8-425 thread design The original, narrow neck size Uniformlyflat bottom ensurescompatibilitywith inserts

    Deactivated 8-425 Screw Top Glass VialsThe same vialsasdescribed previouslywith the addition of a deactivation processto elimi-

    nate sample interactions. Ready-to-use for polar compound analysissuch asphenols, pro-teins, antibodies, amines, metabolites, herbicidesand pesticides. Use with 8-425 screw caps.

    Deactivated 8-425 Screw Top Glass Vials (100/Pk) Part No.Clear deactivated 8-425 screw top, 2 mL 5183-4432

    Amber deactivated 8-425 screw top, 2 mL 5183-4433

    Helpful Hint: M icrovolume insertsare shown on page 31. P/N 5183-4432, 5183-4433

    http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4428http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4429http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4432http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4433http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4433http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4432http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4429http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4428
  • 8/14/2019 Agilent GC catalog .pdf

    30/750

    www.agilent.com/ chem30

    VialsCaps and Septa

    G e n e r alCh r o m at o g r a ph y

    8-425 Screw Caps no Septa (100/Pk) Part No.Black 8-425 screw caps 5183-4438

    Caps8-425 Screw Caps with SeptaOpen top screw capswith the 8 mm septa installed.

    Note: See the Septum Selection Guide to choose the septum best suited for your application.8-425 Screw Caps with Septa (100/Pk) Part No.Black 8-425 screw caps, red PTFE silicone septa 5183-4442

    8-425 Screw Caps (no septa)Open top polypropylene screw capswithout septa. Recommended instead of phenolic caps.Phenolic isa sulfur-based product that can flake and contaminate sampleswhen syringeneedle pushesthrough septum.

    SeptaSepta for 8-425 Screw Top Vials

    Septa for 8-425 Screw Top Vials (100/ Pk) Part No.Red PTFE silicone/red PTFE septa, 8 mm 5183-4436

    Red PTFE silicone septa, 8 mm 5183-4437

    P/N 5183-4442, 5183-4438

    Septa for 8-425 Screw Top Vials

    http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4438http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4442http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4436http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4437http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4437http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4436http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4438http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4442
  • 8/14/2019 Agilent GC catalog .pdf

    31/750

    VialsInserts for 8-425 Vials/ LC Vials

    31www.agilent.com/ chem

    Conical Glass Inserts with Polymer Feet Polymer feet act asthe inserts' shock absorber to allow the syringe needle to strike the bot-tom without being damaged. Thisinsert isself-aligning and standsstraight.

    Conical Glass Inserts with Polymer Feet (100/Pk) Part No.100 L glassinsertswith polymer feet. 5183-2088For 8-425 vials.

    Conical Glass InsertsReady-to-use and require no springs. The most economical for microvolume sampling.

    Conical Glass Inserts (100/ Pk) Part No.100 L pulled-point interior glassinsertsfor 8-425 vials 5183-2089

    Flat Bottom InsertsAn economical limited-volume alternative. M anufactured with tight tolerancesfor a customfit. The extremelyflat bottom without anypush-up protectssyringe needles.

    100 L Flat BottomInserts (100/Pk) Part No.100 L glassflat bottom insertsfor 8-425 vials 5183-2090

    Inserts for 2 mL, 12 x 32 mm 8-425 Screw TopVialsTo meet your microsampling needs, Agilent hasa varietyof microvolume insertswith capaci-tiesand designsthat can transform our vialsfrom full-capacityto limited volume with onesimple step. The insertsfeatured here are compatible with 8-425 screw top vials. (Not for usewith wide opening vials.)

    P/N 5183-2088

    P/N 5183-2089

    P/N 5183-2090

    Vials for Agilent Technologies Liquid

    ChromatographsAgilent Technologiesoffersa varietyof vialsfor Agilent'sLC instruments. Choose from smallvolume vials, 2 mL, and 6 mL vials.

    Agilent minivialsare designed to allow for reproducible injectionsof minute quantities, makingyour limited sample applicationsmore effective and more accurate. Our microvialsprovide lim-ited volumesfor microsampling and the 6 mL capacityvial allowsfor larger sample injections.For a complete selection of vials, capsand septa for LC, refer to the LC section of thiscatalog.

    http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2088http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2088http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2089http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2090http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2090http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2089http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-2088
  • 8/14/2019 Agilent GC catalog .pdf

    32/750

    www.agilent.com/ chem

    Vials4 mL Vials

    G e n e r alCh r o m at o g r a ph y

    32

    Agilent 4 mL Screw Top Vials (100/Pk) Part No.Clear screw top, 4 mL, 15 x 45 vials 5183-4448

    Amber screw top, 4 mL, 15 x 45 vials 5183-4450

    Agilent 4 mL Screw Top Vials, Caps and Septa4 mL, 15 x 45 mm screw top glassvialsare a custom fit to Agilent 6850 autosampler tray

    (G2880A) for use assample aswell aswash vials. Vialswith fill marksare also appropriatefor use aswash vialsand waste vialsin 7673 and 7683 autosamplers. These vialscan alsobe used in Perkin-Elmer Autosystem GC, Waters48 position trayautosampler, ShimadzuAOC-14/1400, LC-10A and the SIL-2AS. Use the 13 x 425 capswith septa for use assamplevialsand with diffusion capsfor wash vials. These vialscan also be used asstorage vials.

    Vial Highlights

    4 mL, 15 x 45 mm Precision formed screw threads(13 x 425) for consistentlysecure seal Custom fit for 7673, 7683 and 6850 autosamplers Can be used aswash, waste or storage vials

    Agilent 4 mL Vials, Caps and Septa Kits Unit Part No.Clear screw top wash vialswith screw caps(no septa) 144/pk 9301-0723

    4 mL wash vialswith fill markingsand caps 25/pk 5182-0551

    Agilent Caps and Septa for 4 mL Screw Top Vials Unit Part No.Black 13 x 425 caps, PTFE/silicone septa 100/pk 5183-4464

    Black open top screw caps 100/pk 5183-4461

    Diffusion caps 12/pk 07673-40180

    PTFE/natural rubber septa 144/pk 9301-1031

    Red PTFE/white silicone septa 100/pk 5183-4460

    White virgin PTFE septa 1000/pk 5183-4459

    P/ N 5183-4448, 5183-4450

    P/ N 9301-0723, 5182-0551

    P/ N 5183-4464, 07673-40180, 5183-4464

    http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4448http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4450http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=9301-0723http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0551http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4464http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4461http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=07673-40180http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=9301-1031http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4460http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4459http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0551http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=9301-0723http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4459http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4460http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=9301-1031http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=07673-40180http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4461http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4464http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4450http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4448
  • 8/14/2019 Agilent GC catalog .pdf

    33/750

    VialsHeadspace Vials

    www.agilent.com/ chem

    33

    Agilent Headspace Crimp Top VialsThese beveled neck vialsare available in both 10 mL and 20 mL capacities, flat or rounded

    bottom. The 20 mm crimp capsprovide a consistentlysecure seal. You can save when youpurchase a pack quantity with vial, cap and septa packaged together in a single container.

    Vial Highlights Beveled top for maximum secure seal Two neck lengthsavailable Choice of a pressure safetyrelease cap at 45 psi Available in flat or rounded bottom designs

    Helpful Hint: For additional Headspace suppliessee the GC InstrumentsPartsand Suppliessection in thiscatalog.

    VialsFlat Bottom Headspace Crimp Top Glass Vials20 mm beveled crimp top createsa much tighter seal than flat crimp surface. The slightlylonger neck iscustom fit for Agilent Technologiesand Carlo Erba. M anufactured to exactingtolerances. Use with 20 mm crimp caps.

    Flat BottomHeadspace Crimp Top Glass Vials (100/ Pk) Part No.Flat bottom Headspace, 20 mL, 23 x 75 mm 5182-0837

    Flat bottom Headspace, 10 mL, 23 x 46 mm 5182-0838

    Rounded Bottom Headspace Crimp Top Glass Vials20 mm beveled crimp top createsa much tighter seal than flat crimp surface. Designed forPerkin-Elmer. Also use with Tekmar and Varian. Heat annealed to 530 C. Use with 20 mmcrimp caps.

    Rounded BottomHeadspace Vials (100/ Pk) Part No.Rounded bottom Headspace, 20 mL, 23 x 75 mm 5183-4474

    Rounded bottom Headspace, 10 mL, 23 x 46 mm 5183-4475

    P/N 5183-4474, 5183-4475

    P/N 5182-0837, 5182-0838

    http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0837http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0838http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4474http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4475http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4475http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4474http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0838http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0837
  • 8/14/2019 Agilent GC catalog .pdf

    34/750

    www.agilent.com/ chem34

    VialsCaps

    G e n e r alCh r o m at o g r a ph y

    Caps20 mm Crimp Caps Only For use with all Headspace crimp top vials. Capswith safetyfeature release pressure atapproximately45 psi.

    Note: Review the Septum Selection Guide to choose the septum best suited for your application.

    20 mmCrimp Caps Without Septa (100/Pk) Part No.Silver aluminum, one piece crimp caps, 20 mm 9301-0721

    Silver aluminum, one piece crimp capswith safetyfeature, 20 mm 9301-0718

    20 mm Crimp Caps with SeptaPre-assembled 20 mm crimp capswith septa. Ready-to-use with anyHeadspace crimp top vials.

    20 mmCrimp Caps with Septa (100/Pk) Part No.Silver aluminum, one piece crimp caps, 20 mm PTFE/silicone septa 5183-4477

    Silver aluminum, one piece crimp capswith safetyfeature, 5183-447820 mm PTFE/silicone septa

    Silver aluminum, one piece crimp caps, 20 mm molded 5183-4479PTFE/butyl septa

    Silver aluminum, one piece crimp capswith safetyfeature, 5183-448020 mm molded PTFE/butyl septa

    P/ N 5183-4477, 5183-4479

    P/ N 9301-0721, 9301-0718

    http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=9301-0721http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=9301-0718http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4477http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4478http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4478http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4479http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4479http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4480http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4480http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4480http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4479http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4478http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5183-4477http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=9301-0718http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=9301-0721
  • 8/14/2019 Agilent GC catalog .pdf

    35/750

    VialsSepta/ Vial Kits/ Storage Vials

    35www.agilent.com/ chem

    Vial KitsSupply Kit

    Supply Kit (100/ Pk) Specs Part No.20 mL flat bottom Headspace crimp top vials, silver 125 C 5182-0840aluminum one-piece crimp capswith safetyfeature,molded PTFE/Silicone Septa

    Septa20 mm Septa

    20 mmSepta (100/ Pk) Specs Part No.Graybutyl stopper, 20 mm -40 C to 120 C 5183-4476

    GrayPTFE/black butyl molded septa, 20 mm -40 C to 125 C 9301-0976

    Tan PTFE/white silicone septa, 20 mm -60 C up to 180 C 9301-0719P/N 5183-4476, 9301-0719, 9301-0976

    Supply Kits

    General Purpose Sample and Storage VialsWith six vial capacitiesavailable in clear or amber glass, Agilent vialsare ideal for samplingor storage. Our Teflon-lined storage capsoffer broad chemical resistance the ultimate inglassclosures. The polypropylene screw capswith Teflon/silicone septa are extra clean toeliminate sample contamination.

    Vials with Solid Storage Caps Unit Part No.4 mL, 15 x 45-vialswith 13-425 caps 100/Pk 5183-4519

    12 mL, 19 x 65-vialswith 15-425 caps 200/Pk 5183-4521

    22 mL, 23 x 85-vialswith 20-400 caps 200/Pk 5183-4523

    40 mL, 28 x 95-vialswith 24-400 caps 100/Pk 5183-4524

    Vial KitsClear Glass Sample Vials with Teflon-Lined Storage CapsPackaged as100 pack of shrink-wrapped clear glasssample vials, with Teflon-lined solid-topstorage capsin resealable plastic bags all in our handycontainer to keep itemsdust-free.

    http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_search=5182-0839http://www.chem.agilent.com/scripts/cabu/p_cas_search_a.asp?prod_s