Advantages versus classic thermosiphon solar...

2
157, Avenue Charles Floquet 93158 Le Blanc Mesnil Cedex - France Phone: + 33 1 45 91 56 00 Fax: + 33 1 45 91 56 89 www.chappee.com Baxi SA au Capital de 43 214 640 RCS Bobigny B 602 041 675 - APE 282 D INITIA DIGIT Gas Wall Hung Boilers CONNECTION TO A SOLAR SYSTEM Thanks to a special kit (including diverter valve and thermostatic mixing valve) installed before the boiler, the water coming from the solar tank will pass through the boiler only when the water temperature is lower than the set point (e.g. 48°C). The boiler will heat the water to the selected temperature. Advantages versus classic thermosiphon solar system : Quicker installation : plug and play pre-assembled system More discrete : aesthetic conception with hidden tank More performant : greater reactivity to the needs Better use of solar energy : stratification and optimised efficiency CHEX1002 Connect an Initia Digit with the new Solar Heat Pipe for a perfect combination of performance, reliability and energetic economies. The solar Heat Pipe is 30% more efficient than the best thermosiphon system found in the market. MAX LENGTH WITHOUT TERMINAL LENGTH REDUCTION WITH A 90° BEND INSERTION m LENGTH REDUCTION WITH A 45° BEND INSERTION m Ø FLUE DISCHARGE mm Ø WALL mm COAXIAL DUCTS 5 1 0,5 60-100 107 SEPARATE DUCTS INSTALLATION WITH WIND PROOF TERMINAL 30 0,5 0,25 80 85 INSTALLATION WITH CHIMEY TERMINAL 15 0,5 0,25 133 140

Transcript of Advantages versus classic thermosiphon solar...

Page 1: Advantages versus classic thermosiphon solar systememslebanon.com/wp-content/uploads/2017/03/initia-digit-EN.pdfInitia Digit 2.24 CF with instantaneous DHW production MR heating system

157, Avenue Charles Floquet93158 Le Blanc Mesnil Cedex - France

Phone: + 33 1 45 91 56 00Fax: + 33 1 45 91 56 89

www.chappee.comBaxi SA au Capital de 43 214 640 €

RCS Bobigny B 602 041 675 - APE 282 D

INITIA DIGIT Gas Wall Hung

Boilers

CONNECTION TO A SOLAR SYSTEM

Thanks to a special kit (including diverter valve and thermostatic mixing

valve) installed before the boiler, the water coming

from the solar tank will pass through the boiler only when the water temperature is lower than the set point

(e.g. 48°C). The boiler will heat the water to the selected temperature.

Advantages versus classic thermosiphon solar system : Quicker installation : plug and play pre-assembled system

More discrete : aesthetic conception with hidden tank

More performant : greater reactivity to the needs

Better use of solar energy : stratifi cation and optimised effi ciency

CHEX

1002

Connect an Initia Digit with the new Solar Heat Pipe for a perfect combination of performance, reliability and energetic economies. The solar Heat Pipe is 30% more effi cient than the best thermosiphon system found in the market.

MAX LENGTHWITHOUT TERMINAL

LENGTH REDUCTION

WITH A 90° BEND INSERTION m

LENGTH REDUCTION

WITH A 45° BEND INSERTION m

Ø FLUEDISCHARGE mm Ø WALL mm

COAXIAL DUCTS 5 1 0,5 60-100 107

SEPARATE DUCTS

INSTALLATION WITH WIND PROOFTERMINAL

30 0,5 0,25 80 85

INSTALLATION WITHCHIMEY TERMINAL 15 0,5 0,25 133 140

Page 2: Advantages versus classic thermosiphon solar systememslebanon.com/wp-content/uploads/2017/03/initia-digit-EN.pdfInitia Digit 2.24 CF with instantaneous DHW production MR heating system

Initia Digit wall hung boilers range combines design, fl exibility and reliability for the maximum comfort. Furthermore, Initia Digit ensures compact dimensions, minimal weight and high performance: up to 16l/min of domestic water production (kT= 25°C)

INITIA DIGIT CHAPPÉE IS A STANDARD

GAS WALL HUNG BOILERS > Heating + instanneous DHW production from 24 to 31 kW

DHW stainless steel plate exchanger

Full anti frost protection

Connection to solar systems

Electronic temperatures control by two NTC probes

Pressure gauge

Electronical gradual ignition and fl ame modulation

Automatic by-pass

Pump and electric three way valve anti-sticking system.

Pressure relief valve on heating system operating at 3 bar

Two ranges of Central Heating temperature (30-85°C for traditional system with radiator and 30-45°C for low temperature system, like under-fl oor heating system). FANNED FLUE

Initia Digit 2.24 FF, 2.31 FF with instantaneous DHW production

OPEN FLUEInitia Digit 2.24 CFwith instantaneous DHW production

MR heating system fl owUS domestic hot water outletGAS gas inletES domestic water inletRR heating system returnA Boiler fi xing points (distance: 425 mm)B Fixing points / connections distances

• Compact brass made hydraulic group with electric 3 way valve.

• The easy frontal access to the components makes the maintenance very simple.

• Reliability and easiness of use : careful

choice of all Initia Digit components ensures high reliability and quality.

IP 4Dx

2.31 FF 2.24 FF/2.24 CF

Chappée have been present

in the heating and in the DHW sector for

over 150 years, it is one of the most

advanced companies offering high

technological heating solutions.

Chappée has developed a wide

range of wall hung and fl oor standing

condensing boilers, a result of the

perfect combination of leading-edge

technologies and high effi ciency.

The top engineering fi rms in the world

have opted for Chappée.

DHW PRODUCTIONFANNED FLUE OPEN FLUE

DESCRIPTION 2.31 FF 2.24 FF 2.24 CFMaximum heat input (nominal) kW 30,1 26,3 26,3Maximum heat input kW 11,3 10,6 10,6Maximum heat output (nominal kW 28 24 24Maximum heat output kW 10,4 9,3 9,3Maximum effi ciency (nominal) % 93,1 92,9 91,2Effi ciency at 30% % 90,5 90,2 88,7

Energetic effi ciency (CE/92/42) 222 222 22

Sealed combustion chamber i i -Expansion vessel l/bar 10/0,5 8/0,5 8/0,5Maximum pressure on heating circuit bar 3 3 3

Regulation of water tempereture in DHW circuit °C 35/60 35/60 35/60Continuous DHW production kT 25°C l/min 16,0 13,7 13,7Continuous DHW production kT 35°C l/min 11,4 9,8 9,8Minimum capacity DWH fl ow rate l/min 2 2 2Minimum pressure on DHW system bar 0,15 0,15 0,15Maximum pressure on DHW system bar 8 8 8

Dimension : height mm 760 760 760 width mm 450 450 450 depth mm 345 345 345Flue tube Ø mm - - 120Coaxial/Dual fl ue tube Ø mm 60-100/80 60-100/80 -

Gas type Methane/LPG Methane/LPG Methane/LPGInlet supply pressure (Methane) mbar 20 20 20Inlet supply pressure LPG (G30/G31) mbar -/37 30/37 30/37

Voltage V 230 230 230Power consumption W 165 135 80Grade of protection IPX4D IPX4D IPX4D

Initia Digit is provided with an innovative LCD display : all working parameters and anomalies are displayed through easy and clear symbols and codes to make the information clear and prompt.

• BURNER LIGHTED• LACK OF GAS

• RESET • ANOMALY WARNING

• CH OPERATION • DHW OPERATION

• TEMPERATURE / ANOMALYCODES DISPLAY

• LACK OF WATER

• DHW TEMPERATURE ADJUSTING CONTROL

• HEATING TEMPERATURE ADJUSTING CONTROL

• LCD DISPLAY

• SUMMER-WINTER-RESETSELECTOR

IP 4Dx